Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Monte Carlo Sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

Synergies from using higher order symplectic decompositions both for ordinary differential equations and quantum Monte Carlo methods

Decomposition methods of the Suzuki-Trotter type of various orders have been derived in different fields. Applying them both to classical ordinary differential equations (ODEs) and quantum systems allows to judge their effectiveness and gives new insights for many body quantum mechanics where reference data are scarce. Further, based on data for 6 × 6 system we conclude that sampling with sign (minus-sign problem) is probably detrimental to the accuracy of fermionic simulations with determinant algorithms.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Inclusive and differential cross-sections for dilepton $t\overline{t}$ production measured in $\sqrt{s}$ = 13 TeV pp collisions with the ATLAS detector

Differential and double-differential distributions of kinematic variables of leptons from decays of top-quark pairs ($t\bar{t}$) are measured using the full LHC Run 2 data sample collected with the ATLAS detector. The data were collected at a pp collision energy of $\sqrt{s}$ = 13 TeV and correspond to an integrated luminosity of 140 fb –1 . The measurements use events containing an oppositely charged e μ pair and b-tagged jets. The results are compared with predictions from several Monte Carlo generators. While no prediction is found to be consistent with all distributions, a better agreement with measurements of the lepton p T distributions is obtained by reweighting the $t\bar{t}$ sample so as to reproduce the top-quark p T distribution from an NNLO calculation. The inclusive top-quark pair production cross-section is measured as well, both in a fiducial region and in the full phase-space. The total inclusive cross-section is found to be $σ_{t\bar{t}}=$ 829 ± 1 (stat) ± 13 (syst) ± 8 (lumi) ± 2 (beam) pb, where the uncertainties are due to statistics, systematic effects, the integrated luminosity and the beam energy. This is in excellent agreement with the theoretical expectation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

FAINT SUBMILLIMETER GALAXY COUNTS AT 450 {mu}m

We present the results of SCUBA-2 observations at 450 {mu}m and 850 {mu}m of the field lensed by the massive cluster A370. With a total survey area >100 arcmin{sup 2} and 1{sigma} sensitivities of 3.92 and 0.82 mJy beam{sup -1} at 450 and 850 {mu}m, respectively, we find a secure sample of 20 sources at 450 {mu}m and 26 sources at 850 {mu}m with a signal-to-noise ratio (S/N) > 4. Using the latest lensing model of A370 and Monte Carlo simulations, we derive the number counts at both wavelengths. The 450 {mu}m number counts probe a factor of four deeper than the counts recently obtained from the Herschel Space Telescope at similar wavelengths, and we estimate that {approx}47%-61% of the 450 {mu}m extragalactic background light resolved into individual sources with 450 {mu}m fluxes greater than 4.5 mJy. The faint 450 {mu}m sources in the 4{sigma} sample have positional accuracies of 3 arcsec, while brighter sources (S/N >6{sigma}) are good to 1.4 arcsec. Using a deep radio map (1{sigma} {approx} 6 {mu}Jy) we find that the percentage of submillimeter sources having secure radio counterparts is 85% for 450 {mu}m sources with intrinsic fluxes >6 mJy and 67% for 850 {mu}m sources with intrinsic fluxes >4 mJy. We also find that 67% of the >4{sigma} 450 {mu}m sources are detected at 850 {mu}m, while the recovery rate at 450 {mu}m of >4{sigma} 850 {mu}m sources is 54%. Combined with the source redshifts estimated using millimetric flux ratios, the recovered rate is consistent with the scenario where both 450 {mu}m and 20 cm emission preferentially select lower redshift dusty sources, while 850 {mu}m emission traces a higher fraction of dusty sources at higher redshifts. We identify potential counterparts in various wavelengths from X-ray to mid-infrared and measure the multiwavelength photometry, which we then use to analyze the characteristics of the sources. We find three X-ray counterparts to our robust submillimeter sample (S/N > 5), giving an active galactic nucleus fraction for our 450 (850) {mu}m sample of 3/8 (3/9) or 38% (33%). We also find a correlation between the K{sub s} band and the 850 {mu}m/20 cm flux ratio.

79 ASTRONOMY AND ASTROPHYSICS↗

Optimizing moderator dimensions for neutron scattering at the spallation neutron source

In this work, we investigate the effect of neutron moderator dimensions on the performance of neutron scattering instruments at the Spallation Neutron Source (SNS). In a recent study of the planned second target station at the SNS facility, we have found that the dimensions of a moderator play a significant role in determining its surface brightness. A smaller moderator may be significantly brighter over a smaller viewing area. One of the immediate implications of this finding is that for modern neutron scattering instrument designs, moderator dimensions and brightness have to be incorporated as an integrated optimization parameter. Here, we establish a strategy of matching neutron scattering instruments with moderators using analytical and Monte Carlo techniques. In order to simplify our treatment, we group the instruments into two broad categories: those with natural collimation and those that use neutron guide systems. For instruments using natural collimation, the optimal moderator selection depends on the size of the moderator, the sample, and the moderator brightness. The desired beam divergence only plays a role in determining the distance between sample and moderator. For instruments using neutron optical systems, the smallest moderator available that is larger than the entrance dimension of the closest optical element will perform the best (assuming, as is the case here that smaller moderators are brighter)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Proton beam scattering system optimization for clinical and research applications

Purpose: To develop and test a method for optimizing and constructing a dual scattering system in passively scattered proton therapy. Methods: A beam optics optimization algorithm was developed to optimize the thickness of the first scatterer (S1) and the profile (of both the high-Z material and Lexan) of the second scatterer (S2) to deliver a proton beam matching a given set of parameters, including field diameter, fluence, flatness, and symmetry. A new manufacturing process was also tested that allows the contoured second scattering foil to be created much more economically and quickly using Cerrobend casting. Two application-specific scattering systems were developed and tested using both experimental and Monte Carlo techniques to validate the optimization process described. Results: A scattering system was optimized and constructed to deliver large uniform irradiations of radiobiology samples at low dose rates. This system was successfully built and tested using film and ionization chambers. The system delivered a uniform radiation field of 50 cm diameter (to a dose of {+-}7% of the central axis) while the depth dose profile could be tuned to match the specifications of the particular investigator using modulator wheels and range shifters. A second scattering system for intermediate field size (4 cm < diameter < 10 cm) stereotactic radiosurgery and radiation therapy (SRS and SRT) treatments was also developed and tested using GEANT4. This system improved beam efficiency by over 70% compared with existing scattering systems while maintaining field flatness and depth dose profile. In both cases the proton range uniformity across the radiation field was maintained, further indicating the accuracy of the energy loss formalism in the optimization algorithm. Conclusions: The methods described allow for rapid prototyping of scattering foils to meet the demands of both research and clinical beam delivery applications in proton therapy.

60 APPLIED LIFE SCIENCES↗

STATISTICAL ANALYSIS OF INTERFEROMETRIC MEASUREMENTS OF AXIS RATIOS FOR CLASSICAL Be STARS

This work presents a novel method to estimate the effective opening angle of CBe star disks from projected axis ratio measurements, obtained by interferometry using a statistical approach. A Monte Carlo scheme was used to generate a large set of theoretical axis ratios from disk models using different distributions of disk densities and opening angles. These theoretical samples were then compared to observational samples, using a two-sample Kolmogorov-Smirnov test, to determine which theoretical distribution best reproduces the observations. The results suggest that the observed ratio distributions in the K, H, and N band can best be explained by the presence of thin disks, with opening half-angles of the order of 0.°15-4.°0. Results for measurements over the Hα line point toward slightly thicker disks, 3.°7-14°, which is consistent with a flaring disk predicted by the viscous disk model.

79 ASTRONOMY AND ASTROPHYSICS↗

Statistical validation of event predictors: A comparative study based on the field of seizure prediction

The prediction of events is of substantial interest in many research areas. To evaluate the performance of prediction methods, the statistical validation of these methods is of utmost importance. Here, we compare an analytical validation method to numerical approaches that are based on Monte Carlo simulations. The comparison is performed in the field of the prediction of epileptic seizures. In contrast to the analytical validation method, we found that for numerical validation methods insufficient but realistic sample sizes can lead to invalid high rates of false positive conclusions. Hence we outline necessary preconditions for sound statistical tests on above chance predictions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Point-spread functions for backscattered imaging in the scanning electron microscope

One knows the imaging system's properties are central to the correct interpretation of any image. In a scanning electron microscope regions of different composition generally interact in a highly nonlinear way during signal generation. Using Monte Carlo simulations we found that in resin-embedded, heavy metal-stained biological specimens staining is sufficiently dilute to allow an approximately linear treatment. We then mapped point-spread functions for backscattered-electron contrast, for primary energies of 3 and 7 keV and for different detector specifications. The point-spread functions are surprisingly well confined (both laterally and in depth) compared even to the distribution of only those scattered electrons that leave the sample again.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A fast Monte Carlo cell-by-cell simulation for radiobiological effects in targeted radionuclide therapy using pre-calculated single-particle track standard DNA damage data

Introduction: We developed a new method that drastically speeds up radiobiological Monte Carlo radiation-track-structure (MC-RTS) calculations on a cell-by-cell basis. Methods: The technique is based on random sampling and superposition of single-particle track (SPT) standard DNA damage (SDD) files from a “pre-calculated” data library, constructed using the RTS code TOPAS-nBio, with “time stamps” manually added to incorporate dose-rate effects. This time-stamped SDD file can then be input into MEDRAS, a mechanistic kinetic model that calculates various radiation-induced biological endpoints, such as DNA double-strand breaks (DSBs), misrepairs and chromosomal aberrations, and cell death. As a benchmark validation of the approach, we calculated the predicted energy-dependent DSB yield and the ratio of direct-to-total DNA damage, both of which agreed with published in vitro experimental data. We subsequently applied the method to perform a superfast cell-by-cell simulation of an experimental in vitro system consisting of neuroendocrine tumor cells uniformly incubated with 177 Lu. Results and discussion: The results for residual DSBs, both at 24 and 48 h post-irradiation, are in line with the published literature values. Our work serves as a proof-of-concept demonstration of the feasibility of a cost-effective “in silico clonogenic cell survival assay” for the computational design and development of radiopharmaceuticals and novel radiotherapy treatments more generally.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Three dimensional dose distribution comparison of simple and complex acquisition trajectories in dedicated breast CT

Purpose: A novel breast CT system capable of arbitrary 3D trajectories has been developed to address cone beam sampling insufficiency as well as to image further into the patient’s chest wall. The purpose of this study was to characterize any trajectory-related differences in 3D x-ray dose distribution in a pendant target when imaged with different orbits. Methods: Two acquisition trajectories were evaluated: circular azimuthal (no-tilt) and sinusoidal (saddle) orbit with ±15° tilts around a pendant breast, using Monte Carlo simulations as well as physical measurements. Simulations were performed with tungsten (W) filtration of a W-anode source; the simulated source flux was normalized to the measured exposure of a W-anode source. A water-filled cylindrical phantom was divided into 1 cm{sup 3} voxels, and the cumulative energy deposited was tracked in each voxel. Energy deposited per voxel was converted to dose, yielding the 3D distributed dose volumes. Additionally, three cylindrical phantoms of different diameters (10, 12.5, and 15 cm) and an anthropomorphic breast phantom, initially filled with water (mimicking pure fibroglandular tissue) and then with a 75% methanol-25% water mixture (mimicking 50–50 fibroglandular-adipose tissues), were used to simulate the pendant breast geometry and scanned on the physical system. Ionization chamber calibrated radiochromic film was used to determine the dose delivered in a 2D plane through the center of the volume for a fully 3D CT scan using the different orbits. Results: Measured experimental results for the same exposure indicated that the mean dose measured throughout the central slice for different diameters ranged from 3.93 to 5.28 mGy, with the lowest average dose measured on the largest cylinder with water mimicking a homogeneously fibroglandular breast. These results align well with the cylinder phantom Monte Carlo studies which also showed a marginal difference in dose delivered by a saddle trajectory in the central slice. Regardless of phantom material or filled fluid density, dose delivered by the saddle scan was negligibly different than the simple circular, no-tilt scans. The average dose measured in the breast phantom was marginally higher for saddle than the circular no tilt scan at 3.82 and 3.87 mGy, respectively. Conclusions: Not only does nontraditional 3D-trajectory CT scanning yield more complete sampling of the breast volume but also has comparable dose deposition throughout the breast and anterior chest volume, as verified by Monte Carlo simulation and physical measurements.

60 APPLIED LIFE SCIENCES↗

CONSTRAINTS ON THE UBIQUITY OF CORONAL X-RAY CYCLES

Stellar activity cycles are known to be a widespread phenomenon amongst moderately active solar- and late-type stars from long-term periodic variations in chromospheric Ca II H and K emission lines, yet to date, only a handful of coronal X-ray cycles are known. We have surveyed serendipitously observed stellar sources in fields observed multiple times in the last decade by XMM-Newton and present our analysis of nine stars from six fields. Since our sample is flux-limited, it is strongly biased toward higher levels of X-ray activity. We fit a single temperature APEC spectrum to each source and search for significant periodicities using a Lomb-Scargle periodogram. We use a Monte Carlo (MC) algorithm to yield robust analysis of the statistical significance of cycle detections and non-detections. None of the nine stellar light curves show any convincing indications of periodicity. From MC simulations, we simulate the detection capabilities of our methodology and, assuming a uniform distribution of cycle periods and strengths over the domain searched, we conclude with 95% confidence that less than 72% of the stars represented by our sample of active stars have 5-13 year coronal X-ray cycles.

79 ASTRONOMY AND ASTROPHYSICS↗

Kernel Density Estimators for SAMPLER Analyses [Slides]

This presentation discusses Sampler, specifically in terms of uncertainty quantification and states that for many simulation tasks nominal input parameters have complicated influence on the uncertainty in the final result. Sampler provides a convenient means to perform stochastic uncertainty quantification, brute force sampling parameter space and tallying changes in outputs, and it can be coupled with any SCALE modules. Perturbed responses can be collected and analyzed with standard statistical measures; however, two problems have been identified. The first problem is that for Monte Carlo simulations the individual response uncertainties are ignored, and the second problem is that features of distributions are easily hidden in histograms. They found that the solution is to add Kernel Density Estimator (KDE) analysis to the Sampler output. In conclusion, Sampler is a unique tool for stochastic uncertainty propagation, and it can be coupled with any module in SCALE. Current functionality is limited to histograms, and it may not adequately account for sample uncertainties and/or not adequately display underlying distribution features. Work is in progress to implement KDE in the Sampler module and no additional flagging is needed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

MEASUREMENT OF THE RADIUS OF NEUTRON STARS WITH HIGH SIGNAL-TO-NOISE QUIESCENT LOW-MASS X-RAY BINARIES IN GLOBULAR CLUSTERS

This paper presents the measurement of the neutron star (NS) radius using the thermal spectra from quiescent low-mass X-ray binaries (qLMXBs) inside globular clusters (GCs). Recent observations of NSs have presented evidence that cold ultra dense matter-present in the core of NSs-is best described by ''normal matter'' equations of state (EoSs). Such EoSs predict that the radii of NSs, R{sub NS}, are quasi-constant (within measurement errors, of {approx}10%) for astrophysically relevant masses (M{sub NS}>0.5 M{sub Sun }). The present work adopts this theoretical prediction as an assumption, and uses it to constrain a single R{sub NS} value from five qLMXB targets with available high signal-to-noise X-ray spectroscopic data. Employing a Markov chain Monte-Carlo approach, we produce the marginalized posterior distribution for R{sub NS}, constrained to be the same value for all five NSs in the sample. An effort was made to include all quantifiable sources of uncertainty into the uncertainty of the quoted radius measurement. These include the uncertainties in the distances to the GCs, the uncertainties due to the Galactic absorption in the direction of the GCs, and the possibility of a hard power-law spectral component for count excesses at high photon energy, which are observed in some qLMXBs in the Galactic plane. Using conservative assumptions, we found that the radius, common to the five qLMXBs and constant for a wide range of masses, lies in the low range of possible NS radii, R{sub NS}=9.1{sup +1.3}{sub -1.5} km (90%-confidence). Such a value is consistent with low-R{sub NS} equations of state. We compare this result with previous radius measurements of NSs from various analyses of different types of systems. In addition, we compare the spectral analyses of individual qLMXBs to previous works.

79 ASTRONOMY AND ASTROPHYSICS↗

Efficient, automated Monte Carlo methods for radiation transport

Monte Carlo simulations provide an indispensible model for solving radiative transport problems, but their slow convergence inhibits their use as an everyday computational tool. In this paper, we present two new ideas for accelerating the convergence of Monte Carlo algorithms based upon an efficient algorithm that couples simulations of forward and adjoint transport equations. Forward random walks are first processed in stages, each using a fixed sample size, and information from stage k is used to alter the sampling and weighting procedure in stage k+1. This produces rapid geometric convergence and accounts for dramatic gains in the efficiency of the forward computation. In case still greater accuracy is required in the forward solution, information from an adjoint simulation can be added to extend the geometric learning of the forward solution. The resulting new approach should find widespread use when fast, accurate simulations of the transport equation are needed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Testing oscillating primordial spectrum and oscillating dark energy with astronomical observations

In this paper we revisit the issue of determining the oscillating primordial scalar power spectrum and oscillating equation of state of dark energy from the astronomical observations. By performing a global analysis with the Markov Chain Monte Carlo method, we find that the current observations from five-year WMAP and SDSS-LRG matter power spectrum, as well as the ''union'' supernovae sample, constrain the oscillating index of primordial spectrum and oscillating equation of state of dark energy with the amplitude less than |n{sub amp}| < 0.116 and |w{sub amp}| < 0.232 at 95% confidence level, respectively. This result shows that the oscillatory structures on the primordial scalar spectrum and the equation of state of dark energy are still allowed by the current data. Furthermore, we point out that these kinds of modulation effects will be detectable (or gotten a stronger constraint) in the near future astronomical observations, such as the PLANCK satellite, LAMOST telescope and the currently ongoing supernovae projects SNLS.

79 ASTRONOMY AND ASTROPHYSICS↗

Sci—Thur AM: YIS - 03: irtGPUMCD: a new GPU-calculated dosimetry code for {sup 177}Lu-octreotate radionuclide therapy of neuroendocrine tumors

In peptide receptor radionuclide therapy (PRRT), huge inter-patient variability in absorbed radiation doses per administered activity mandates the utilization of individualized dosimetry to evaluate therapeutic efficacy and toxicity. We created a reliable GPU-calculated dosimetry code (irtGPUMCD) and assessed {sup 177}Lu-octreotate renal dosimetry in eight patients (4 cycles of approximately 7.4 GBq). irtGPUMCD was derived from a brachytherapy dosimetry code (bGPUMCD), which was adapted to {sup 177}Lu PRRT dosimetry. Serial quantitative single-photon emission computed tomography (SPECT) images were obtained from three SPECT/CT acquisitions performed at 4, 24 and 72 hours after {sup 177}Lu-octreotate administration, and registered with non-rigid deformation of CT volumes, to obtain {sup 177}Lu-octreotate 4D quantitative biodistribution. Local energy deposition from the β disintegrations was assumed. Using Monte Carlo gamma photon transportation, irtGPUMCD computed dose rate at each time point. Average kidney absorbed dose was obtained from 1-cm{sup 3} VOI dose rate samples on each cortex, subjected to a biexponential curve fit. Integration of the latter time-dose rate curve yielded the renal absorbed dose. The mean renal dose per administered activity was 0.48 ± 0.13 Gy/GBq (range: 0.30–0.71 Gy/GBq). Comparison to another PRRT dosimetry code (VRAK: Voxelized Registration and Kinetics) showed fair accordance with irtGPUMCD (11.4 ± 6.8 %, range: 3.3–26.2%). These results suggest the possibility to use the irtGPUMCD code in order to personalize administered activity in PRRT. This could allow improving clinical outcomes by maximizing per-cycle tumor doses, without exceeding the tolerable renal dose.

60 APPLIED LIFE SCIENCES↗

Low-temperature magnetization relaxation in magnetic molecular solids

The low temperature relaxation of the magnetization in molecular magnetic solids such as Fe{sub 8} is studied using Monte Carlo simulations. A set of rate equations is then developed to understand the simulations, and the results are compared. The simulations show that the magnetization of an initially saturated sample deviates as a square-root in time at short times, as observed experimentally, and this law is derived from the rate equations analytically. -- Highlights: •A novel set of non-linear rate equations for the coupled evolution of the magnetization and dipole field distribution. •An analytic derivation of the short-time square root in time behavior of the magnetization relaxation. •Agreement between theory and simulations without further fitting parameters.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Diffusion Quantum Monte Carlo Benchmarking of Magnetic Moments in MnBi 2 Te 4

The intrinsically antiferromagnetic topological insulator, MnBi 2 Te 4 (MBT), has garnered significant attention recently due to its potential to host numerous exotic topological quantum states. Unfortunately, their consistent realization has been hindered by intrinsic antisite defects among the Mn and Bi sublattices. In this work, we establish Mn magnetization of pristine MBT through high level diffusion Monte Carlo calculations, which can serve as a precise starting point for various models to estimate antisite defect concentrations in actual MBT samples. The benchmark quality of DMC calculations is further identified from out model estimating antisite defect concentrations, which combines the benchmarked Mn magnetization with data from magnetic susceptibility and intermediate field magnetization measurements. This reproduces well Bi Mn and Mn Bi concentrations measured in the experiments. Here, we anticipate these theoretically based magnetic purity measures may be used as minimization targets in cycles of refinement to synthesize MBT with low antisite defect concentrations and more reproducible topological properties.

Defects↗