Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Modal”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

Forced Response Aeromechanics Analysis in MATLAB®-Based Environment Code With Application to Distortion-Tolerant Fan R24 Blade Geometry

Researchers at the NASA Glenn Research Center have developed a research-level code for forced response analysis for turbomachinery that provides a streamlined framework for aeromechanics analysis, as well as for generating Goodman diagrams. The Forced Response Aeromechanics Analysis in a MATLAB-Based Environment (FRAAME, Version 1) code is designed to accept blade surface unsteady pressure time histories generated by three-dimensional (3D) Unsteady Reynolds-Averaged Navier-Stokes (URANS) code TURBO and modal displacements, modal stresses, and static stresses generated via expanded ANSYS® (Ansys, Inc.) cyclic symmetry analysis. The code’s looping structure allows for largescale analyses, including many blade surface pressure files, modal displacements, and modal stress files for full annulus forced response analysis, including a modal summation method for multiple engine orders and modes. This code is applied to the R24 fan geometry for the Boundary Layer Ingesting Inlet/Distortion-Tolerant Fan (BLI2DTF) project, a propulsion system being developed to increase the fuel efficiency of future aircraft, to serve as validation of experimental data as well as external simulation results. This tool’s functional, modular form is intended to allow users to make modifications easily. Those modifications can include requests for information for any step in the analysis process, as well as adding various functions to compute additional information of interest. It is also written, given sufficient input information, as a general blade geometry forced response solver that is not necessarily specific to the R24 geometry but is used here for verification of code functionality and accuracy. Although forced response analysis tools are also available in commercially available code packages, the post-processing FRAAME code offers reliable, fast, and scalable forced response analysis and Goodman diagram generation for large cases utilizing, specifically, TURBO and ANSYS® results information in an effort to streamline forced response and high cycle fatigue analyses.

Aeromechanics↗

MultiDimChemImaging v1.30

The purpose of this software is to correlate and visualize multidimensional chemical images where the different modalities were collected with different resolution and/or offset. List of features: - change dimension of data stored in XYZ (XYcoordinate, value) or Comma Separated Values (CSV) formats via bipolar or bicubic interpolation - determine and apply offset between different modalities - create a multimodal image file from multiple single modalities in Tab Separate Values (TSV) or TissueViewTM (industry standard for chemical image visualization) formats - visualize and save (whole or partial) composite chemical images made of multiple (up to 3 at once) modalities Specific application: correlated multidimensional chemical imaging by AFM-based nano-thermal (nano-TA) analysis coupled to spectroscopy and mass spectrometry for spatially resolved surface analysis. In case of a phase separated polymer film, the modalities were: 1. topography image 203. IR images collected at two different wavelengths 4-5. mass spectral chemical images of two different m/z values.

Kertesz, Vilmos↗

Upgrade and Certification of the Los Alamos National Laboratory SHENC 2011 - 12270

Nondestructive assay measurements of Transuranic (TRU) waste at Los Alamos National Laboratory (LANL) required the addition of a standard waste box (SWB) assay system. A Super High Efficiency Neutron Counter (SHENC) located at Hanford was identified to be relocated to LANL. After careful evaluation of waste streams at LANL, it was determined that the current configuration of the SHENC was not sufficient to quantify certain waste streams. At LANL, there is still a large amount of waste that needs to be retrieved and repackaged within SWB's to meet agreements with the State of New Mexico. Prior to relocating the SHENC, the only assay systems available were High Efficiency Neutron Counters having only a 55-gallon drum capacity. Further analyses indicated that the SHENC system should be capable of quantitative gamma measurements that are to be linked, and combined, with the neutron measurements. The SHENC system was therefore augmented with a new high-resolution gamma spectroscopy system using BE5030 detectors and upgraded gamma electronics. The neutron side of the system was also upgraded with an advanced shift register (JSR-15), an improved Programmable Logic Controller and NDA-2000 software. This report will include calibration of both the neutron and gamma modalities of the SHENC system and how the modality results are combined to produce a single assay result. Preliminary performance results will be discussed based on both mock and real waste measurements. Discussions will also include a complete description of the adjustable parameters as well as the calibration plan, techniques and validations including calibration confirmation based on the Waste Isolation Pilot Plant Waste Acceptance Criteria (WIPP-WAC). The SHENC was successfully upgraded to efficiently measure the complex waste streams at Los Alamos National Laboratory. A new PLC was successfully added to the system for Add-A-Source control. A new shift register was added to the SHENC (JSR-15) which provides more flexibility if replacement is required. The addition of the density based calibration on the gamma modality of the system increases the effectiveness of the SHENC for high alpha-n producing waste. Upgrading the system to new software also helped to standardize the program at Los Alamos. Only one new procedure was initiated for the integration of the SHENC. Add-A-Source measurements were effectively integrated with the system based on the confirmation results and positive results during two Department of Energy Performance Demonstration Program Box Cycles. Total measurement uncertainty estimates were completed for both the gamma modality and the neutron modality of the system. The SHENC was reviewed by both the Department of Energy and the Environmental Protection Agency in 2011. The certification letter for the SHENC was issued on November 16, 2011. With the certification letter issued to the Central Characterization Project the SHENC can perform waste measurements on SWB's at Los Alamos for shipment to WIPP. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Comparing Free-Free and Shaker Table Model Correlation Methods Using Jim Beam

Finite element model correlation as part of a spacecraft program has always been a challenge. For any NASA mission, the coupled system response of the spacecraft and launch vehicle can be determined analytically through a Coupled Loads Analysis (CLA), as it is not possible to test the spacecraft and launch vehicle coupled system before launch. The value of the CLA is highly dependent on the accuracy of the frequencies and mode shapes extracted from the spacecraft model. NASA standards require the spacecraft model used in the final Verification Loads Cycle to be correlated by either a modal test or by comparison of the model with Frequency Response Functions (FRFs) obtained during the environmental qualification test. Due to budgetary and time constraints, most programs opt to correlate the spacecraft dynamic model during the environmental qualification test, conducted on a large shaker table. For any model correlation effort, the key has always been finding a proper definition of the boundary conditions. This paper is a correlation case study to investigate the difference in responses of a simple structure using a free-free boundary, a fixed boundary on the shaker table, and a base-drive vibration test, all using identical instrumentation. The NAVCON Jim Beam test structure, featured in the IMAC round robin modal test of 2009, was selected as a simple, well recognized and well characterized structure to conduct this investigation. First, a free-free impact modal test of the Jim Beam was done as an experimental control. Second, the Jim Beam was mounted to a large 20,000 lbf shaker, and an impact modal test in this fixed configuration was conducted. Lastly, a vibration test of the Jim Beam was conducted on the shaker table. The free-free impact test, the fixed impact test, and the base-drive test were used to assess the effect of the shaker modes, evaluate the validity of fixed-base modeling assumptions, and compare final model correlation results between these boundary conditions.

Modal Test↗

Electronic health record analysis via deep poisson factor models

Electronic Health Record (EHR) phenotyping utilizes patient data captured through normal medical practice, to identify features that may represent computational medical phenotypes. These features may be used to identify at-risk patients and improve prediction of patient morbidity and mortality. We present a novel deep multi-modality architecture for EHR analysis (applicable to joint analysis of multiple forms of EHR data), based on Poisson Factor Analysis (PFA) modules. Each modality, composed of observed counts, is represented as a Poisson distribution, parameterized in terms of hidden binary units. In-formation from different modalities is shared via a deep hierarchy of common hidden units. Activation of these binary units occurs with probability characterized as Bernoulli-Poisson link functions, instead of more traditional logistic link functions. In addition, we demon-strate that PFA modules can be adapted to discriminative modalities. To compute model parameters, we derive efficient Markov Chain Monte Carlo (MCMC) inference that scales efficiently, with significant computational gains when compared to related models based on logistic link functions. To explore the utility of these models, we apply them to a subset of patients from the Duke-Durham patient cohort. We identified a cohort of over 12,000 patients with Type 2 Diabetes Mellitus (T2DM) based on diagnosis codes and laboratory tests out of our patient population of over 240,000. Examining the common hidden units uniting the PFA modules, we identify patient features that represent medical concepts. Experiments indicate that our learned features are better able to predict mortality and morbidity than clinical features identified previously in a large-scale clinical trial.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Influence of Numerical Modeling Approaches on Damped Behavior of Flexible Beams: Preprint

Composites structures are widely used in aerospace and wind energy applications for their excellent stiffness and strength-to-weight properties. In these structures, structural damping is critical to predict vibration amplitudes, performance, and reliability. Structural damping is of particular interest for slender wings, rotorcraft blades, and wind turbine blades that can exhibit complex vibration phenomena and are frequently modeled with geometrically exact beam theory (GEBT). Standard approaches of stiffness proportional or modal damping merely assign user defined values and cannot predict damping behavior. This work compares stiffness proportional damping to two more advanced damping approaches: modal strain energy and Prony series. The modal strain energy approach uses a sectional analysis tool to calculate the beam stiffness and postprocess internal stresses from GEBT simulations. The internal stresses are then used to calculate modal damping factors. The Prony series is implemented within GEBT to directly model viscoelastic behavior of the composites. These approaches are compared by modeling the evolution of the damping factors of a realistic flexible wind turbine blade with varying rotational speed. Discrepancies between the approaches suggest areas for future modeling development, but differences in nonlinear damping values are less than current uncertainties about the magnitude of structural damping.

17 WIND ENERGY↗

Neuroimaging in adult penetrating brain injury: a guide for radiographers

Penetrating brain injuries (PBI) are a medical emergency, often resulting in complex damage and high mortality rates. Neuroimaging is essential to evaluate the location and extent of injuries, and to manage them accordingly. Currently, a myriad of imaging modalities are included in the diagnostic workup for adult PBI, including skull radiography, computed tomography (CT), magnetic resonance imaging (MRI) and angiography, with each modality providing their own particular benefits. This literature review explores the current modalities available for investigating PBI and aims to assist in decision making for the appropriate use of diagnostic imaging when presented with an adult PBI. Based on the current literature, the authors have developed an imaging pathway for adult penetrating brain injury that functions as both a learning tool and reference guide for radiographers and other health professionals. Currently, CT is recommended as the imaging modality of choice for the initial assessment of PBI patients, while MRI is important in the sub-acute setting where it aids prognosis prediction and rehabilitation planning, Additional follow-up imaging, such as angiography, should be dependent upon clinical findings.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of C-arm Computed Tomography and Digital Subtraction Angiography in Patients with Chronic Thromboembolic Pulmonary Hypertension

PurposeTo assess the feasibility and diagnostic performance of contrast-enhanced, C-arm computed tomography (CACT) of the pulmonary arteries compared to digital subtraction angiography (DSA) in patients suffering from chronic thromboembolic pulmonary hypertension (CTEPH).MaterialsFifty-two patients with CTEPH underwent ECG-gated DSA and contrast-enhanced CACT. Two readers (R1, R2) independently evaluated pulmonary artery segments and their sub-segmental branching using DSA and CACT for optimal image quality. Afterwards, the diagnostic findings, i.e., intraluminal filling defects, stenosis, and occlusion, were compared. Inter-modality and inter-observer agreement was calculated, and subsequently consensus reading was done and correlated to a reference standard representing the overall consensus of both modalities. Fisher’s exact test and Cohen’s Kappa were applied.ResultsA total of 1352 pulmonary segments were evaluated, of which 1255 (92.8 %) on DSA and 1256 (92.9 %) on CACT were rated to be fully diagnostic. The main causes of the non-diagnostic image quality were motion artifacts on CACT (R1:37, R2:78) and insufficient contrast enhancement on DSA (R1:59, R2:38). Inter-observer agreement was good for DSA (κ = 0.74) and CACT (κ = 0.75), while inter-modality agreement was moderate (R1: κ = 0.46, R2: κ = 0.47). Compared to the reference standard, the inter-modality agreement for CACT was excellent (κ = 0.96), whereas it was inferior for DSA (κ = 0.61) due to the higher number of abnormal consensus findings read as normal on DSA.ConclusionCACT of the pulmonary arteries is feasible and provides additional information to DSA. CACT has the potential to improve the diagnostic work-up of patients with CTEPH and may be particularly useful prior to surgical or interventional treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multimodality Imaging for the Assessment of Pericardial Diseases

Purpose of Review: The diagnosis of pericardial syndromes, while occasionally straightforward, includes a wide range of pathologies and is often a well-recognized clinical challenge. The aim of this review is to highlight the key role of the various imaging modalities for the diagnosis and management of the spectrum of pericardial diseases. Recent Findings: Cardiac imaging has become an integral part of the diagnostic process often beginning with echocardiography and supported by advanced imaging modalities including computed tomography, magnetic resonance imaging, and positive emission tomography. These modalities go beyond the simple identification of the pericardium, to identifying increased pericardial thickness, active pericardial edema and inflammation, and its effect on cardiac hemodynamics. Summary: Multimodality imaging has significantly facilitated the diagnosis and long-term management of patients with pericardial diseases. The role of these imaging modalities in overall prognosis and prevention remains to be investigated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Anti-PD-1 Blockade and Stereotactic Radiation Produce Long-Term Survival in Mice With Intracranial Gliomas

Purpose: Glioblastoma multiforme (GBM) is the most common primary brain tumor in adults, and radiation is one of the main treatment modalities. However, cure rates remain low despite best available therapies. Immunotherapy is a promising modality that could work synergistically with radiation, which has been shown to increase antigen presentation and promote a proinflammatory tumor microenvironment. Programmed-death-1 (PD-1) is a surface receptor expressed on activated and exhausted T cells, which mediate T cell inhibition upon binding with its ligand PD-L1, expressed on many tumor types including human GBMs. We tested the combination of anti-PD-1 immunotherapy with stereotactic radiosurgery in a mouse orthotopic GBM model. Methods and Materials: We performed intracranial implantation of mouse glioma cell line GL261 transfected with luciferase into C57BL/6 mice. Mice were stratified into 4 treatment groups: (1) control; (2) radiation only; (3) anti-PD-1 antibody only; and (4) radiation plus anti-PD-1 antibody. Overall survival was quantified. The mice were killed on day 21 after implantation to assess immunologic parameters in the brain/tumor, cervical lymph nodes, and spleen. Results: Improved survival was demonstrated with combination anti-PD-1 therapy plus radiation compared with either modality alone: median survival was 25 days in the control arm, 27 days in the anti-PD-1 antibody arm, 28 days in the radiation arm, and 53 days in the radiation plus anti-PD-1 therapy arm (P<.05 by log-rank Mantle-Cox). Long-term survival was seen only in the combined treatment arm, with a fraction (15%-40%) of animals alive at day 180+ after treatment. Immunologic data on day 21 after implantation showed increased tumor infiltration by cytotoxic T cells (CD8+/interferon-γ+/tumor necrosis factor-α+) and decreased regulatory T cells (CD4+/FOXP3) in the combined treatment group compared with the single modality arms. Conclusions: The combination of PD-1 blockade and localized radiation therapy results in long-term survival in mice with orthotopic brain tumors. These studies provide strong preclinical evidence to support combination trials in patients with GBM.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Predictors of Postoperative Complications After Trimodality Therapy for Esophageal Cancer

Purpose: While trimodality therapy for esophageal cancer has improved patient outcomes, surgical complication rates remain high. The goal of this study was to identify modifiable factors associated with postoperative complications after neoadjuvant chemoradiation. Methods and Materials: From 1998 to 2011, 444 patients were treated at our institution with surgical resection after chemoradiation. Postoperative (pulmonary, gastrointestinal [GI], cardiac, wound healing) complications were recorded up to 30 days postoperatively. Kruskal-Wallis tests and χ{sup 2} or Fisher exact tests were used to assess associations between continuous and categorical variables. Multivariate logistic regression tested the association between perioperative complications and patient or treatment factors that were significant on univariate analysis. Results: The most frequent postoperative complications after trimodality therapy were pulmonary (25%) and GI (23%). Lung capacity and the type of radiation modality used were independent predictors of pulmonary and GI complications. After adjusting for confounding factors, pulmonary and GI complications were increased in patients treated with 3-dimensional conformal radiation therapy (3D-CRT) versus intensity modulated radiation therapy (IMRT; odds ratio [OR], 2.018; 95% confidence interval [CI], 1.104-3.688; OR, 1.704; 95% CI, 1.03-2.82, respectively) and for patients treated with 3D-CRT versus proton beam therapy (PBT; OR, 3.154; 95% CI, 1.365-7.289; OR, 1.55; 95% CI, 0.78-3.08, respectively). Mean lung radiation dose (MLD) was strongly associated with pulmonary complications, and the differences in toxicities seen for the radiation modalities could be fully accounted for by the MLD delivered by each of the modalities. Conclusions: The radiation modality used can be a strong mitigating factor of postoperative complications after neoadjuvant chemoradiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A dosimetric comparison of 3D-CRT, IMRT, and static tomotherapy with an SIB for large and small breast volumes

Radiation therapy to the breast is a complex task, with many different techniques that can be employed to ensure adequate dose target coverage while minimizing doses to the organs at risk. This study compares the dose planning outcomes of 3 radiation treatment modalities, 3 dimensional conformal radiation therapy (3D-CRT), intensity-modulated radiation therapy (IMRT), and static tomotherapy, for left-sided whole-breast radiation treatment with a simultaneous integrated boost (SIB). Overall, 20 patients with left-sided breast cancer were separated into 2 cohorts, small and large, based on breast volume. Dose plans were produced for each patient using 3D-CRT, IMRT, and static tomotherapy. All patients were prescribed a dose of 45 Gy in 20 fractions to the breast with an SIB of 56 Gy in 20 fractions to the tumor bed and normalized so that D{sub 98%} > 95% of the prescription dose. Dosimetric comparisons were made between the 3 modalities and the interaction of patient size. All 3 modalities offered adequate planning target volume (PTV) coverage with D{sub 98%} > 95% and D{sub 2%} < 107%. Static tomotherapy offered significantly improved (p = 0.006) dose homogeneity to the PTV{sub boost} {sub eval} (0.079 ± 0.011) and breast minus the SIB volume (Breast{sub SIB}) (p < 0.001, 0.15 ± 0.03) compared with the PTV{sub boost} {sub eval} (0.085 ± 0.008, 0.088 ± 0.12) and Breast{sub SIB} (0.22 ± 0.05, 0.23 ± 0.03) for IMRT and 3D-CRT, respectively. Static tomotherapy also offered statistically significant reductions (p < 0.001) in doses to the ipsilateral lung mean dose of 6.79 ± 2.11 Gy compared with 7.75 ± 2.54 Gy and 8.29 ± 2.76 Gy for IMRT and 3D-CRT, respectively, and significantly (p < 0.001) reduced heart doses (mean = 2.83 ± 1.26 Gy) compared to both IMRT and 3D-CRT (mean = 3.70 ± 1.44 Gy and 3.91 ± 1.58 Gy). Static tomotherapy is the dosimetrically superior modality for the whole breast with an SIB compared with IMRT and 3D-CRT. IMRT is superior to 3D-CRT in both PTV dose conformity and reduction of mean doses to the ipsilateral lung.

61 RADIATION PROTECTION AND DOSIMETRY↗

Adjuvant radiation therapy for bladder cancer: A dosimetric comparison of techniques

Trials of adjuvant radiation after cystectomy are under development. There are no studies comparing radiation techniques to inform trial design. This study assesses the effect on bowel and rectal dose of 3 different modalities treating 2 proposed alternative clinical target volumes (CTVs). Contours of the bowel, rectum, CTV-pelvic sidewall (common/internal/external iliac and obturator nodes), and CTV-comprehensive (CTV-pelvic sidewall plus cystectomy bed and presacral regions) were drawn on simulation images of 7 post-cystectomy patients. We optimized 3-dimensional conformal radiation (3-D), intensity-modulated radiation (IMRT), and single-field uniform dose (SFUD) scanning proton plans for each CTV. Mixed models regression was used to compare plans for bowel and rectal volumes exposed to 35% (V{sub 35%}), 65% (V{sub 65%}), and 95% (V{sub 95%}) of the prescribed dose. For any given treatment modality, treating the larger CTV-comprehensive volume compared with treating only the CTV-pelvic sidewall nodes significantly increased rectal dose (V{sub 35%} {sub rectum}, V{sub 65%} {sub rectum}, and V{sub 95%} {sub rectum}; p < 0.001 for all comparisons), but it did not produce significant differences in bowel dose (V{sub 95%} {sub bowel}, V{sub 65%} {sub bowel}, or V{sub 35%} {sub bowel}). The 3-D plans, compared with both the IMRT and the SFUD plans, had a significantly greater V{sub 65%} {sub bowel} and V{sub 95%} {sub bowel} for each proposed CTV (p < 0.001 for all comparisons). The effect of treatment modality on rectal dosimetry differed by CTV, but it generally favored the IMRT and the SFUD plans over the 3-D plans. Comparison of the IMRT plan vs the SFUD plan yielded mixed results with no consistent advantage for the SFUD plan over the IMRT plan. Targeting a CTV that spares the cystectomy bed and presacral region may marginally improve rectal toxicity but would not be expected to improve the bowel toxicity associated with any given modality of adjuvant radiation. Using the IMRT or the SFUD plans instead of the 3-D conformal plan may improve both bowel and rectal toxicity.

61 RADIATION PROTECTION AND DOSIMETRY↗

A unified large language model–based framework for heterogeneous PV image diagnosis

With advances in imaging technologies, modern photovoltaic (PV) systems generate large volumes of heterogeneous image data, including visible, electroluminescence (EL), and infrared (IR) images. Existing PV image analysis models, particularly deep learning approaches, are typically task-specific and lack cross-modality generalization. To address this limitation, this paper proposes an open-source large language model (LLM)–based unified framework for heterogeneous PV image diagnostics. Through task-aware diagnostic prompting, the framework enables analysis of visible, EL, and IR images within a single pipeline, supporting both zero-shot and few-shot inference and binary and multiclass classification. It is compatible with state-of-the-art multimodal LLMs, including ChatGPT, Gemini, Claude, Qwen, and CLIP. The framework is evaluated on PV module condition classification (clean, soiling, snow, hail, and bird droppings) using visible images, cell crack detection using EL images, and hotspot detection using IR images. GPT-5.1 in few-shot mode achieves the best performance, with classification accuracy exceeding 97.3%. Open-source models such as Qwen and CLIP also deliver competitive results on visible images (around 90% accuracy), though their performance is more limited on EL and IR modalities. On the full ELPV dataset, the framework achieves 83.5% zero-shot accuracy, within 2.8% of the supervised CNN baseline, confirming scalability to larger benchmarks. Practical aspects such as reproducibility, response latency, and confidence estimation are systematically analyzed. The framework operates across PV image modalities without modality- or task-specific training, making it well suited as a rapid pre-screening tool to support downstream detailed diagnostics. A benchmark dataset of diverse labeled PV images is also released.

Li, Baojie↗

Shaker-structure interaction modeling and analysis for nonlinear force appropriation testing

Nonlinear force appropriation is an extension of its linear counterpart where sinusoidal excitation is applied to a structure with a modal shaker and phase quadrature is achieved between the excitation and response. While a standard practice in modal testing, modal shaker excitation has the potential to alter the dynamics of the structure under test. Previous studies have been conducted to address several concerns, but this work specifically focuses on a shaker-structure interaction phenomenon which arises during the force appropriation testing of a nonlinear structure. Under pure-tone sinusoidal forcing, a nonlinear structure may respond not only at the fundamental harmonic but also potentially at sub- or superharmonics, or it can even produce aperiodic and chaotic motion in certain cases. Shaker-structure interaction occurs when the response physically pushes back against the shaker attachment, producing non-fundamental harmonic content in the force measured by the load cell, even for pure tone voltage input to the shaker. This work develops a model to replicate these physics and investigates their influence on the response of a nonlinear normal mode of the structure. Experimental evidence is first provided that demonstrates the generation of harmonic content in the measured load cell force during a force appropriation test. This interaction is replicated by developing an electromechanical model of a modal shaker attached to a nonlinear, three-mass dynamical system. Several simulated experiments are conducted both with and without the shaker model in order to identify which effects are specifically due to the presence of the shaker. Finally, the results of these simulations are then compared to the undamped nonlinear normal modes of the structure under test to evaluate the influence of shaker-structure interaction on the identified system’s dynamics.

42 ENGINEERING↗

Co-orchestration of multiple instruments to uncover structure–property relationships in combinatorial libraries

The rapid growth of automated and autonomous instrumentation brings forth opportunities for the co-orchestration of multimodal tools that are equipped with multiple sequential detection methods or several characterization techniques to explore identical samples. This is exemplified by combinatorial libraries that can be explored in multiple locations via multiple tools simultaneously or downstream characterization in automated synthesis systems. In co-orchestration approaches, information gained in one modality should accelerate the discovery of other modalities. Correspondingly, an orchestrating agent should select the measurement modality based on the anticipated knowledge gain and measurement cost. Herein, we propose and implement a co-orchestration approach for conducting measurements with complex observables, such as spectra or images. The method relies on combining dimensionality reduction by variational autoencoders with representation learning for control over the latent space structure and integration into an iterative workflow via multi-task Gaussian Processes (GPs). This approach further allows for the native incorporation of the system's physics via a probabilistic model as a mean function of the GPs. We illustrate this method for different modes of piezoresponse force microscopy and micro-Raman spectroscopy on a combinatorial Sm-BiFeO3 library. However, the proposed framework is general and can be extended to multiple measurement modalities and arbitrary dimensionality of the measured signals.

47 OTHER INSTRUMENTATION↗

General parity-odd CMB bispectrum estimation

We develop a methodology for estimating parity-odd bispectra in the cosmic microwave background (CMB). This is achieved through the extension of the original separable modal methodology to parity-odd bispectrum domains (ℓ{sub 1}+ℓ{sub 2}+ℓ{sub 3} = odd). Through numerical tests of the parity-odd modal decomposition with some theoretical bispectrum templates, we verify that the parity-odd modal methodology can successfully reproduce the CMB bispectrum, without numerical instabilities. We also present simulated non-Gaussian maps produced by modal-decomposed parity-odd bispectra, and show the consistency with the exact results. Our new methodology is applicable to all types of parity-odd temperature and polarization bispectra.

79 ASTRONOMY AND ASTROPHYSICS↗

Audiovisual Fusion: Challenges and New Approaches

In this study, we review recent results on audiovisual (AV) fusion. We also discuss some of the challenges and report on approaches to address them. One important issue in AV fusion is how the modalities interact and influence each other. This review will address this question in the context of AV speech processing, and especially speech recognition, where one of the issues is that the modalities both interact but also sometimes appear to desynchronize from each other. An additional issue that sometimes arises is that one of the modalities may be missing at test time, although it is available at training time; for example, it may be possible to collect AV training data while only having access to audio at test time. We will review approaches to address this issue from the area of multiview learning, where the goal is to learn a model or representation for each of the modalities separately while taking advantage of the rich multimodal training data. In addition to multiview learning, we also discuss the recent application of deep learning (DL) toward AV fusion. We finally draw conclusions and offer our assessment of the future in the area of AV fusion.

47 OTHER INSTRUMENTATION↗