Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Microscope and microscopy.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

Scanning tunneling microscopy studies of diamond films and optoelectronic materials

In this report, we report on progress achieved from 12/1/92 to 10/1/93 under the grant entitled 'Scanning Tunneling Microscopy Studies of Diamond Films and Optoelectronic Materials'. We have set-up a chemical vapor deposition (CVD) diamond film growth system and a Raman spectroscopy system to study the nucleation and growth of diamond films with atomic resolution using scanning tunneling microscopy (STM). A unique feature of the diamond film growth system is that diamond films can be transferred directly to the ultrahigh vacuum (UHV) chamber of a scanning tunneling microscope without contaminating the films by exposure to air. The University of North Texas (UNT) provided $20,000 this year as matching funds for the NASA grant to purchase the diamond growth system. In addition, UNT provided a Coherent Innova 90S Argon ion laser, a Spex 1404 double spectrometer, and a Newport optical table costing $90,000 to set-up the Raman spectroscopy system. The CVD diamond growth system and Raman spectroscopy system will be used to grow and characterize diamond films with atomic resolution using STM as described in our proposal. One full-time graduate student and one full-time undergraduate student are supported under this grant. In addition, several graduate and undergraduate students were supported during the summer to assist in setting-up the diamond growth and Raman spectroscopy systems. We have obtained research results concerning STM of the structural and electronic properties of CVD grown diamond films, and STM and scanning tunneling spectroscopy of carbon nanotubes. In collaboration with the transmission electron microscopy (TEM) group at UNT, we have also obtained results concerning the optoelectronic material siloxene. These results were published in refereed scientific journals, submitted for publication, and presented as invited and contributed talks at scientific conferences.

Perez, Jose M.↗

Experimental Determination of Ultra-Sharp Stray Field Distribution from a Magnetic Vortex Core Structure

The fine magnetic stray field from a vortex structure of micron-sized permalloy (Ni{sub 80}Fe{sub 20}) elements has been studied by high-resolution magnetic force microscopy. By systematically studying the width of the stray field gradient distribution at different tip-to-sample distances, we show that the half-width at half-maximum (HWHM) of the signal from vortex core can be as narrow as {approx}21 nm at a closest tip-to-sample distance of 23 nm, even including the convolution effect of the finite size of the magnetic tip. A weak circular reverse component is found around the center of the magnetic vortex in the measured magnetic force microscope (MFM) signals, which can be attributed to the reverse magnetization around the vortex core. Successive micromagnetic and MFM imaging simulations show good agreements with our experimental results on the width of the stray field distribution.

36 MATERIALS SCIENCE↗

Immunohistochemical myofiber typing and high-resolution myofibrillar lesion detection in LR white embedded muscle

We have developed a method of fixing, embedding, sectioning, and staining that allows high-resolution detection of myofibrillar structure and myosin immunocytochemical muscle fiber typing in serial semithin sections of LR White plastic embedded muscle at the light microscopic level. Traditional approaches, such as cryostat sections, permit fiber typing, but small myofibrillar lesions (1-3 sarcomeres) are difficult to detect because of section thickness. Semithin sections of hydrophobic resins do not stain well either histochemically or immunocytochemically. Electron microscopy can resolve lesions and discriminate fiber types based on morphology, but the sampling area is small. Our goal was to develop a rapid method for defining both fiber type and high-resolution primary myofibrillar lesion damage. Mild fixation (1-4% paraformaldehyde, 0. 05-0.1% glutaraldehyde) and embedment in a hydrophilic resin (LR White) were used. Myofibrillar structure was extremely well preserved at the light microscopic (LM) level, and lesions could be readily resolved in Toluidine blue stained 500-nm sections. Fiber type was defined by LM immunomyosin staining of serial plastic semithin sections, which demonstrated reciprocal staining patterns for "fast (Sigma M4276) and "total" (skeletal muscle) myosins (Sigma M7523). Copyright 2000 Wiley-Liss, Inc.

NASA Program Fundamental Space Biology↗

Transport and Assembly of Magnetic Surface Rotors**

This minireview focuses on recent advances with surface magnetic rotors, namely field-responsive spherical or anisotropic microparticles that translate close to, or are embedded in a confining surface. The application of external magnetic modulations allows these microscopic wheels to be remotely spun and steered while also tuning their interactions and inducing assembly from a collection of disordered, moving units. With optical microscopy one can observe and characterize the complex collective phenomena that emerge in dissipative colloidal systems driven far from equilibrium by external fields. From a technological point of view, magnetic surface rotors envisage implementation into microfluidic devices, and can be used for drug delivery, mixing as well as a model system for biological active matter.

36 MATERIALS SCIENCE↗

Dark Field Microscopy for Analytical Laboratory Courses

An innovative and inexpensive optical microscopy experiment for a quantitative analysis or an instrumental analysis chemistry course is described. The students have hands-on experience with a dark field microscope and investigate the wavelength dependence of localized surface plasmon resonance in gold and silver nanoparticles. Students also observe and measure individual crystal growth during a replacement reaction between copper and silver nitrate. The experiment allows for quantitative, qualitative, and image data analyses for undergraduate students.

36 MATERIALS SCIENCE↗

Comparison of the structural and chemical composition of two unique micro/nanostructures produced by femtosecond laser interactions on nickel

The structural and chemical composition of two unique microstructures formed on nickel, with nanoscale features, produced using femtosecond laser surface processing (FLSP) techniques is reported in this paper. These two surface morphologies, termed mounds and nanoparticle-covered pyramids, are part of a larger class of self-organized micro/nanostructured surfaces formed using FLSP. Cross-sections of the structures produced using focused ion beam milling techniques were analyzed with a transmission electron microscope. Both morphologies have a solid core with a layer of nanoparticles on the surface. Energy dispersive X-ray spectroscopy by scanning transmission electron microscopy studies reveal that the nanoparticles are a nickel oxide, while the core material is pure nickel.

36 MATERIALS SCIENCE↗

Quantitative and simultaneous analysis of the polarity of polycrystalline ZnO seed layers and related nanowires grown by wet chemical deposition

The polarity in ZnO nanowires is an important issue since it strongly affects surface configuration and reactivity, nucleation and growth, electro-optical properties, and nanoscaleengineering device performances. However, measuring statistically the polarity of ZnO nanowire arrays grown by chemical bath deposition and elucidating its correlation with the polarity of the underneath polycrystalline ZnO seed layer grown by the sol–gel process represents a major difficulty. To address that issue, we combine resonant x-ray diffraction (XRD) at Zn K-edge using synchrotron radiation with piezoelectric force microscopy and polarity-sensitive chemical etching to statistically investigate the polarity of more than 107 nano-objects both on the macroscopic and local microscopic scales, respectively. By using high temperature annealing under an argon atmosphere, it is shown that the compact, highly c-axis oriented ZnO seed layer is more than 92% Zn-polar and that only a few small O-polar ZnO grains with an amount less than 8% are formed. Correlatively, the resulting ZnO nanowires are also found to be Zn-polar, indicating that their polarity is transferred from the c-axis oriented ZnO grains acting as nucleation sites in the seed layer. These findings pave the way for the development of new strategies to form unipolar ZnO nanowire arrays as a requirement for a number of nanoscaleengineering devices like piezoelectric nanogenerators. They also highlight the great advantage of resonant XRD as a macroscopic, non-destructive method to simultaneously and statistically measure the polarity of ZnO nanowire arrays and of the underneath ZnO seed layer.

nanowires↗

Combining variational autoencoders and physical bias for improved microscopy data analysis *

Electron and scanning probe microscopy produce vast amounts of data in the form of images or hyperspectral data, such as electron energy loss spectroscopy or 4D scanning transmission electron microscope, that contain information on a wide range of structural, physical, and chemical properties of materials. To extract valuable insights from these data, it is crucial to identify physically separate regions in the data, such as phases, ferroic variants, and boundaries between them. In order to derive an easily interpretable feature analysis, combining with well-defined boundaries in a principled and unsupervised manner, here we present a physics augmented machine learning method which combines the capability of variational autoencoders to disentangle factors of variability within the data and the physics driven loss function that seeks to minimize the total length of the discontinuities in images corresponding to latent representations. Our method is applied to various materials, including NiO-LSMO, BiFeO 3 , and graphene. The results demonstrate the effectiveness of our approach in extracting meaningful information from large volumes of imaging data. The customized codes of the required functions and classes to develop phyVAE is available at https://github.com/arpanbiswas52/phy-VAE.

97 MATHEMATICS AND COMPUTING↗

Visualizing superconductivity in a doped Weyl semimetal with broken inversion symmetry

The Weyl semimetal Mo Te 2 offers a rare opportunity to study the interplay between Weyl physics and superconductivity. Recent studies have found that Se substitution can boost the superconductivity up to 1.5 K, but suppresses the T d structure phase that is essential for the emergence of the Weyl state. A microscopic understanding of the possible coexistence of enhanced superconductivity and the T d phase has not been established so far. Here, we use scanning tunneling microscopy to study an optimally doped superconductor Mo Te 1.85 Se 0.15 with bulk T c ~ 1.5 K . By means of quasiparticle interference imaging, we identify the existence of a low-temperature T d phase with broken inversion symmetry where superconductivity globally coexists. Furthermore, we find that the superconducting coherence length, extracted from both the upper critical field and the decay of density of states near a vortex, is much larger than the characteristic length scale of the existing chemical disorder. Overall, our findings of robust superconductivity arising from a Weyl semimetal normal phase in Mo Te 1.85 Se 0.15 make it a promising candidate for realizing topological superconductivity.

36 MATERIALS SCIENCE↗

Model-based determination of dielectric function by STEM low-loss EELS

Dielectric properties of materials are crucial in describing the electromagnetic response of materials. As devices are becoming considerably smaller than the optical wavelength, the conventional measuring methods based on optical response are limited by their spatial resolution. Electron energy loss spectroscopy performed in a scanning transmission electron microscope is a good alternative to obtain the dielectric properties with excellent spatial resolution. Due to the overlap of diffraction discs in scanning transmission electron microscopy, it is difficult to apply conventional experimental settings to suppress retardation losses. In this contribution, a relativistic dielectric model for the loss function is presented which is used in a model based optimization scheme to estimate the complex electric function of a material. The method is applied to experiments on bulk diamond and SrTiO{sub 3} and shows a good agreement with optical reference data when retardation effects are included. Application of this technique to nanoparticles is possible but several theoretical assumptions made in the model of the loss function are violated and interpretation becomes problematic.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Atomic Force Microscopy Beyond the Standard Quantum Limit

We explore the impact of quantum noise reduction on force microscopy for broadband off-resonant materials characterization by integrating a multi-spatial-mode squeezed state as the readout field in a commercially available microscope.

Lawrie, Benjamin J.↗

Atomic Force Microscope Active Optical Probe for Single-Molecule Imaging and Time-Resolved Optical Spectroscopy (DOE SBIR Phase II/IIA Final Report)

Actoprobe LLC reports on the results of its DOE SBIR Phase II/IIA project on the development of Atomic Force Microscope Active Optical Probe for Single-Molecule Imaging and Time-Resolved Optical Spectroscopy. While chemistry science and technology greatly benefit from Atomic Force Microscopy in surface characterization, time-resolved chemical imaging on the single-molecule level lags far behind. Current scanning probe microscopy only obtains information about mechanical but not optical/chemical properties. To address this problem, the Actoprobe LLC research team has proposed a novel class of Atomic Force Microscopy probes, Ultra-Fast Pulsed Active Atomic Force Microscopy Optical Probes (UFP AAOPs), that will allow ultrafast time-resolved optical and chemical imaging at the nanoscale. As envisioned, these unique optical probes will perform the functions of conventional Atomic Force Microscopy probes and, in addition, will simultaneously provide chemical information about molecular scale interactions. This innovation is accomplished by integrating an ultrafast pulsed Quantum Dot laser source into an Atomic Force Microscopy probe. This report describes our progress with the fabrication of an ultrafast micrometer-size semiconductor laser, based on “artificial atoms” - Quantum Dots, integrated with an Atomic Force Microscopy probe. In this Phase II/IIA project, we have demonstrated the feasibility of the UFP AAOP concept by fabricating a first prototype of the UFP AAOP. The excellent performance of the probe has been proven in terms of AFM and optical spatial resolution through rigorous tests. The UFP AAOP provides pulses with less than 4 ps duration and higher than 11 GHz repetition rate, and spatial resolution better than 300 nm at 1240 nm wavelength. Technically, it is possible to reduce the pulse width to less than 1 ps and to improve lateral resolution to ~ 0.5 nm, which implies the potential capability for the probe to characterize chemical compounds with single-molecule resolution. The UFP AAOP fabrication procedure has been developed for wafer-scale production of multiple devices, with the yield of the process estimated to be lower than 1% with the limited fabrication capabilities and equipment available for use in the research project. However, using high-volume production tools and special GaAs processing equipment, the yield can be significantly improved, theoretically to ~ 50%. Finally, economic feasibility and scale-up manufacturing potential were analyzed for UFP AAOP and found to be very promising. In summary, the Actoprobe team has successfully demonstrated the feasibility of the UFP AAOP concept.

36 MATERIALS SCIENCE↗

A study of tetrataenite

The tetrataenite in Dayton was examined using conventional transmission (TEM) and analytical electron microscopy (AEM). Tetrataenite was also simulated in terrestrial Fe-Ni alloys through electron irradiation of thin-foil specimens on the high voltage electron microscope (HVEM). The purpose was to correlate the results of the TEM, AEM and HVEM studies on Dayton and on terrestrial iron-nickel alloys to the low temperature iron-nickel phase diagram. Oxide forms spontaneously on the surfaces of thin-foil iron-nickel specimens. By determining the metal/oxide orientation relationships the reflections due to the oxide and the superlattice are distinguished. In Dayaton, the clear taenite (I) is fully ordered until near the cloudy zone interface. The ordered domains ranged in size from 30 to 650 nm with the largest domains corresponding to the highest Ni content and the smallest domain size corresponding to the lowest Ni content. In terrestrial alloys irradiated on the HVEM, the extent of electron irradiation induced ordering was determined as a function of temperature and composition. Ordering occurred in every specimen irradiated.

Reuter, K. B.↗

Scanning tunneling microscopy of the atomically smooth (001) surface of vanadium pentoxide V{sub 2}O{sub 5} crystals

The (001) cleavage surface of vanadium pentoxide (V{sub 2}O{sub 5}) crystal has been studied by scanning tunneling spectroscopy (STM). It is shown that the surface is not reconstructed; the STM image allows geometric lattice parameters to be determined with high accuracy. The nanostructure formed on the (001) cleavage surface of crystal consists of atomically smooth steps with a height multiple of unit-cell parameter c = 4.37 Å. The V{sub 2}O{sub 5} crystal cleavages can be used as references in calibration of a scanning tunneling microscope under atmospheric conditions both along the (Ñ…, y) surface and normally to the sample surface (along the z axis). It is found that the terrace surface is not perfectly atomically smooth; its roughness is estimated to be ~0.5 Å. This circumstance may introduce an additional error into the microscope calibration along the z coordinate.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Local Measurements of Preisach Density in Polycrystalline Ferroelectric Capacitors

Polarization switching in polycrystalline ferroelectric capacitors is explored using piezoresponse force microscopy (PFM) based first-order reversal curve (FORC) measurements. The band excitation method facilitates decoupling the electromechanical responses from variations in surface elastic properties. A simulated annealing method is developed to estimate the Preisach densities from PFM FORC data. Microscopic and macroscopic Preisach densities are compared, illustrating good agreement between the two.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Understanding the deformation mechanism of individual phases of a ZrTi-based bulk metallic glass matrix composite using in situ diffraction and imaging methods

The plasticity of a ZrTi-based bulk metallic glass composite consisting of glassy matrix and crystalline dendritic phase was studied in-situ under identical tensile loading conditions using scanning electron microscopy and synchrotron X-ray diffraction. A generic procedure was developed to separate the diffraction information of the crystalline phases away from that of the matrix and to precisely calculate the microscopic strains of the two phases at different macroscopic load steps. In this way, the time-evolved quantitative links between shear bands nucleation/propagation and the corresponding microscopic stress fields around them are established, providing more quantitative understanding on (1) how the shear bands are driven by the local stress field, and (2) the critical stresses required for the shear bands to nucleate in the crystalline phase, propagate through the crystalline/matrix interface, and finally into the matrix.

36 MATERIALS SCIENCE↗

Ferroelectric domain morphology and structure in Li-doped (K,Na)NbO{sub 3} ceramics

We prepared Li{sub 0.02}(K{sub 0.45}Na{sub 0.55}){sub 0.98}NbO{sub 3} (KNN) ceramics using a conventional solid-state sintering method and investigated the domain structure and morphology using a piezoresponse force microscope in these material systems. The abnormal grain consisted of nano-sized subgrains, which were an elementary unit of the domain formation, with a size of approximately 100 nm. They were self-assembled and grew along the <001>{sub o} directions. In the orthorhombic KNN ceramics, the 90 Degree-Sign domains were dominantly distributed and all wedges were 60 Degree-Sign wedges. The polarization vectors and geometrical configurations were analyzed and suggested in the banded twins. The observation of angles between (010){sub o} and (011){sub o} showed that the large grains experienced severe stress resulting in the deformation of the unit cell configuration during the phase transition. The S-walls were preferred as 120 Degree-Sign domain walls and were assigned to (1/0.27/1){sub c}.

36 MATERIALS SCIENCE↗