Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MIRROR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

Test of the Conserved Vector Current Hypothesis in T=1/2 Mirror Transitions and New Determination of |V{sub ud}|

The V{sub ud} element of the Cabibbo-Kobayashi-Maskawa quark mixing matrix has traditionally been determined from the analysis of data in nuclear superallowed 0{sup +}{yields}0{sup +} transitions, neutron decay, and pion beta decay. After providing a new test of the conserved vector current hypothesis, we present here a new independent determination of |V{sub ud}| from a set of five T=1/2 nuclear mirror transitions. The extracted value, |V{sub ud}|=0.9719{+-}0.0017, is at 1.2 combined standard deviations from the value obtained from superallowed 0{sup +}{yields}0{sup +} transitions and has a precision comparable to the value obtained from neutron decay experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Coherent Scattering of a Multiphoton Quantum Superposition by a Mirror BEC

We present the proposition of an experiment in which the multiphoton quantum superposition consisting of Napprox =10{sup 5} particles generated by a quantum-injected optical parametric amplifier, seeded by a single-photon belonging to an Einstein-Podolsky-Rosen entangled pair, is made to interact with a mirror-Bose-Einstein condensate (BEC) shaped as a Bragg interference structure. The overall process will realize a macroscopic quantum superposition involving a microscopic single-photon state of polarization entangled with the coherent macroscopic transfer of momentum to the BEC structure, acting in spacelike separated distant places.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Three Extra Mirror or Sequential Families: Case for a Heavy Higgs Boson and Inert Doublet

We study the possibility of the existence of extra fermion families and an extra Higgs doublet. We find that requiring the extra Higgs doublet to be inert leaves space for three extra families, allowing for mirror fermion families and a dark matter candidate at the same time. The emerging scenario is very predictive: It consists of a standard model Higgs boson, with a mass above 400 GeV, heavy new quarks between 340 and 500 GeV, light extra neutral leptons, and an inert scalar with a mass below M{sub Z}.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Spatial Properties of High-Order Harmonic Beams from Plasma Mirrors: A Ptychographic Study

Spatial properties of high-order harmonic beams produced by high-intensity laser-matter interactions carry rich information on the physics of the generation process, and their detailed understanding is essential for applications of these light beams. We present a thorough study of these properties in the case of harmonic generation from plasma mirrors, up to the relativistic interaction regime. In situ ptychographic measurements of the amplitude and phase spatial profiles of the different harmonic orders in the target plane are presented, as a function of the key interaction parameters. Further, these measurements are used to validate analytical models of the harmonic spatial phase in different generation regimes, and to benchmark ultrahigh-order Maxwell solvers of particle-in-cell simulation codes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

First Observation of Unbound O 11 , the Mirror of the Halo Nucleus Li 11

The structure of the extremely proton-rich nucleus O 8 11 3 , the mirror of the two-neutron halo nucleus Li 3 11 8 , has been studied experimentally for the first time. Following two-neutron knockout reactions with a O 13 beam, the O 11 decay products were detected after two-proton emission and used to construct an invariant-mass spectrum. A broad peak of width ~ 3.4 MeV was determined. Within the Gamow coupled-channel approach, it was concluded that this peak is a multiplet with contributions from the four lowest O 11 resonant states: J π = 3 / 2 1 - , 3 / 2 2 - , 5 / 2 1 + , and 5 / 2 2 + . The widths and configurations of these states show strong, nonmonotonic dependencies on the depth of the p - C 9 potential. This unusual behavior is due to the presence of a broad threshold resonant state in N 10 , which is an analog of the virtual state in Li 10 in the presence of the Coulomb potential. After optimizing the model to the data, only a moderate isospin asymmetry between ground states of O 11 and Li 11 was discovered.

6 ≤ A ≤ 19↗

Charge Radius of Neutron-Deficient Ni 54 and Symmetry Energy Constraints Using the Difference in Mirror Pair Charge Radii

he nuclear root-mean-square charge radius of Ni 54 was determined with collinear laser spectroscopy to be R ( Ni 54 ) = 3.737 ( 3 ) fm . In conjunction with the known radius of the mirror nucleus Fe 54 , the difference of the charge radii was extracted as Δ R ch = 0.049 ( 4 ) fm . Based on the correlation between Δ R ch and the slope of the symmetry energy at nuclear saturation density ( L ), we deduced 21 ≤ L ≤ 88 MeV . The present result is consistent with the L from the binary neutron star merger GW170817, favoring a soft neutron matter EOS, and barely consistent with the PREX-2 result within 1 σ error bands. Our result indicates the neutron-skin thickness of Ca 48 as 0.15–0.21 fm.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Symmetry of Cosmological Observables, a Mirror World Dark Sector, and the Hubble Constant

We find that a uniform scaling of the gravitational free-fall rates and photon-electron scattering rate leaves most dimensionless cosmological observables nearly invariant. This result opens up a new approach to reconciling cosmic microwave background and large-scale structure observations with high values of the Hubble constant H0: Find a cosmological model in which the scaling transformation can be realized without violating any measurements of quantities not protected by the symmetry. A “mirror world” dark sector allows for effective scaling of the gravitational free-fall rates while respecting the measured mean photon density today. Further model building might bring consistency with the two constraints not yet satisfied: the inferred primordial abundances of deuterium and helium.

79 ASTRONOMY AND ASTROPHYSICS↗

Angular Correlations in the β Decay of B 8 : First Tensor-Current Limits from a Mirror-Nucleus Pair

We present the first measurement of the α–β–ν angular correlation in the Gamow-Teller β + decay of 8 B. This was accomplished using the Beta-decay Paul Trap, expanding on our previous work on the β – decay of 8 Li. The 8 B result is consistent with the V – A electroweak interaction of the standard model and, on its own, provides a limit on the exotic right-handed tensor current relative to the axial-vector current of |C T /C A | 2 < 0.013 at the 95.5% confidence level. This represents the first high-precision angular correlation measurements in mirror decays and was made possible through the use of an ion trap. Here, by combining this 8 B result with our previous 8 Li results, we demonstrate a new pathway for increased precision in searches for exotic currents.

6 ≤ A ≤ 19↗

Novel Measurement of the Neutron Magnetic Form Factor from A=3 Mirror Nuclei

The electromagnetic form factors of the proton and neutron encode information on the spatial structure of their charge and magnetization distributions. While measurements of the proton are relatively straightforward, the lack of a free neutron target makes measurements of the neutron's electromagnetic structure more challenging and more sensitive to experimental or model-dependent uncertainties. Various experiments have attempted to extract the neutron form factors from scattering from the neutron in deuterium, with different techniques providing different, and sometimes large, systematic uncertainties. We present results from a novel measurement of the neutron magnetic form factor using quasielastic scattering from the mirror nuclei 3 H and 3 He, where the nuclear effects are larger than for deuterium but expected to largely cancel in the cross-section ratios. We extracted values of the neutron magnetic form factor for low-to-modest momentum transfer, 0.6 < Q 2 < 2.9 GeV 2 , where existing measurements give inconsistent results. The precision and Q 2 range of these data allow for a better understanding of the current world’s data and suggest a path toward further improvement of our overall understanding of the neutron’s magnetic form factor.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

All-Fiber Optical Faraday Mirror Using 56-wt%-Terbium-Doped Fiber

An all-fiber optical Faraday mirror that consists of a fiber Faraday rotator and a fiber Bragg grating is demonstrated. The fiber Faraday rotator uses a 21-cm-long section of 56-wt%-terbium-doped silicate fiber. The polarization state of the reflected light is rotated 89 degrees +/- 2 degrees with a 16-dB polarization extinction ratio.

Faraday effect↗

Observation of Electromagnetic Transients in a Nb3Sn 4-layer Dipole Mirror Magnet

During testing of the Stress Managed Cosine-Theta dipole mirror magnet SMCTM1, magnet quenches were observed following large voltage spikes in the half-coil voltage taps which preceded normal quench initiation. Following some recent work at CERN measuring power current converter transients in relation to flux jumps, an additional differential current probe was added to the magnet instrumentation. Measurements of this probe, as well as the half coil voltage taps show a fast and substantial current change preceding the quench, hinting at coil motion. A simple model based on relative shift of the inner and outer layer coils was developed which suggests the magnitude of coil shift events is on the estimated relative coil shift from the magnet constraint conditions. The behavior is shown to be reversible and characteristic of stick-slip.

Krave, Steven [Fermilab] (ORCID:0000000217521457)↗

High-accuracy Aspheric X-ray Mirror Metrology Using Software Configurable Optical Test System/deflectometry

The Software Configurable Optical Test System (SCOTS) uses deflectometry to measure surface slopes of general optical shapes without the need for additional null optics. Careful alignment of test geometry and calibration of inherent system error improve the accuracy of SCOTS to a level where it competes with interferometry. We report a SCOTS surface measurement of an off-axis superpolished elliptical x-ray mirror that achieves <1 nm<1 nm root-mean-square accuracy for the surface measurement with low-order term included.

42 ENGINEERING↗

Transfer of autocollimator calibration for use with scanning gantry profilometers for accurate determination of surface slope and curvature of state-of-the-art x-ray mirrors

X-ray optics, desired for beamlines at free-electron-laser and diffraction-limited-storage-ring x-ray light sources, must have almost perfect surfaces, capable of delivering light to experiments without significant degradation of brightness and coherence. To accurately characterize such optics at an optical metrology lab, two basic types of surface slope profilometers are used: The long trace profilers (LTPs) and nanometer optical measuring (NOM) like angular deflectometers, based on electronic autocollimator (AC) ELCOMAT-3000. The inherent systematic errors of the instrument's optical sensors set the principle limit to their measuring performance. Where autocollimator of a NOM-like profiler may be calibrated at a unique dedicated facility, this is for a particular configuration of distance, aperture size, and angular range that does not always match the exact use in a scanning measurement with the profiler. Here we discuss the developed methodology, experimental set-up, and numerical methods of transferring the calibration of one reference AC to the scanning AC of the Optical Surface Measuring System (OSMS), recently brought to operation at the ALS Xray Optics Laboratory. We show that precision calibration of the OSMS performed in three steps, allows us to provide high confidence and accuracy low-spatial-frequency metrology and not â€print into' measurements the inherent systematic error of tool in use. Here, with the examples of the OSMS measurements with a state-of-The-Art x-ray aspherical mirror, available from one of the most advanced vendors of X-ray optics, we demonstrate the high efficacy of the developed calibration procedure. The results of our work are important for obtaining high reliability data, needed for sophisticated numerical simulations of beamline performance and optimization of beamline usage of the optics. This work was supported by the U. S. Department of Energy under contract number DE-AC02-05CH11231.

47 OTHER INSTRUMENTATION↗

Broadband, 920-nm mirror thin film damage competition

This year’s competition proposed to survey the state-of-the-art broadband, near-IR multilayer dielectric (MLD) mirrors designed for ultra-short, pulsed laser applications. The requirements for the coatings were a minimum reflection of 99.5% at 45-degree incidence angle for S-polarization from 830 nm to 1010 nm and group delay dispersion (GDD) < ± 50 fs 2 . The participants in this effort selected the coating materials, coating design, and deposition method. Samples were damage tested at a single testing facility to enable direct comparison among the participants using a 25 ± 5 fs OPCPA laser system operating at 5 Hz. A double blind test assured sample and submitter anonymity. The damage performance results, sample rankings, details of the deposition processes, coating materials and substrate cleaning methods are shared here. We found that multilayer coatings using tantala and/or hafnia as high index materials were top performers within several coating deposition groups. Specifically, dense coatings by ion-beam sputtering (IBS), magnetron sputtering (MS), and electron-beam ion assisted deposition (e-beam IAD) exhibited highest damage initiation onset (LIDT) while e-beam coatings were low performers. In addition, damage growth onset (LDGT) was also examined and the results are reported here for all samples as this performance metric plays an important role in establishing the safe operational conditions for larger aperture, ultrashort pulsed lasers. As a result, not all coating samples in the survey met the GDD requirements stated above and associated measurements are discussed in the context of the present and past competitions focused on similar broadband, near-IR MLD coatings.

42 ENGINEERING↗

SU-E-T-774: Use of a Scintillator-Mirror-Camera System for the Measurement of MLC Leakage Radiation with the CyberKnife M6 System

Purpose: A technique using a scintillator-mirror-camera system to measure MLC leakage was developed to provide an efficient alternative to film dosimetry while maintaining high spatial resolution. This work describes the technique together with measurement uncertainties. Methods: Leakage measurements were made for the InCise™ MLC using the Logos XRV-2020A device. For each measurement approximately 170 leakage and background images were acquired using optimized camera settings. Average background was subtracted from each leakage frame before filtering the integrated leakage image to replace anomalous pixels. Pixel value to dose conversion was performed using a calibration image. Mean leakage was calculated within an ROI corresponding to the primary beam, and maximum leakage was determined by binning the image into overlapping 1mm x 1mm ROIs. 48 measurements were performed using 3 cameras and multiple MLC-linac combinations in varying beam orientations, with each compared to film dosimetry. Optical and environmental influences were also investigated. Results: Measurement time with the XRV-2020A was 8 minutes vs. 50 minutes using radiochromic film, and results were available immediately. Camera radiation exposure degraded measurement accuracy. With a relatively undamaged camera, mean leakage agreed with film measurement to ≤0.02% in 92% cases, ≤0.03% in 100% (for maximum leakage the values were 88% and 96%) relative to reference open field dose. The estimated camera lifetime over which this agreement is maintained is at least 150 measurements, and can be monitored using reference field exposures. A dependency on camera temperature was identified and a reduction in sensitivity with distance from image center due to optical distortion was characterized. Conclusion: With periodic monitoring of the degree of camera radiation damage, the XRV-2020A system can be used to measure MLC leakage. This represents a significant time saving when compared to the traditional film-based approach without any substantial reduction in accuracy.

60 APPLIED LIFE SCIENCES↗

Ultrafast manipulation of mirror domain walls in a charge density wave

Domain walls (DWs) are singularities in an ordered medium that often host exotic phenomena such as charge ordering, insulator-metal transition, or superconductivity. The ability to locally write and erase DWs is highly desirable, as it allows one to design material functionality by patterning DWs in specific configurations. We demonstrate such capability at room temperature in a charge density wave (CDW), a macroscopic condensate of electrons and phonons, in ultrathin 1T-TaS 2 . A single femtosecond light pulse is shown to locally inject or remove mirror DWs in the CDW condensate, with probabilities tunable by pulse energy and temperature. Using time-resolved electron diffraction, we are able to simultaneously track anti-synchronized CDW amplitude oscillations from both the lattice and the condensate, where photoinjected DWs lead to a red-shifted frequency. Our demonstration of reversible DW manipulation may pave new ways for engineering correlated material systems with light.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Study of the development of relativistic plasma bunches in a long mirror trap by optical and X-ray imaging and numerical simulations

The work presents experimental results demonstrating the feasibility of autoresonance acceleration of electrons in a long mirror trap with a reverse magnetic field. It is shown that gyromagnetic autoresonance results in the formation of a plasma bunch with average electron energy of several hundred keV, which is confined for a long time in the trap. The results of computer simulations of the regime of reverse gyromagnetic autoresonance agree well with the experimental data.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurements of the Plasma Parameters in a Mirror Trap by Means of Laser-Induced Fluorescence

Results of measurements of the absolute density of ArII ions in a mirror trap with a toroidal divertor are presented. The ion density was measured by the method of laser-induced fluorescence with the use of ArII metastable states. A technique is proposed to estimate the plasma electron temperature from the ratio of the fluorescence signals obtained by comparing the intensities of different optical transitions of ArII.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗