Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Learning with errors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,445 records · Page 81

Can protein expression be ‘solved’?

Recombinant protein expression is central to biotechnology’s application in academic exploration as well as human health, climate applications and the bioeconomy in general. However, not all proteins can be expressed in all organisms, and the field lacks a predictive model of soluble protein overexpression that could replace laborious experimental trial-and-error. Here, we discuss the state of the field and identify the lack of large, high-fidelity datasets as the primary bottleneck to progress. We review possible assays that could be used for data collection to identify a path toward an extensible experimental platform for collecting soluble recombinant protein overexpression data across organisms. We suggest that the resulting dataset should be used to train increasingly generalizable predictive models of protein expression to answer the question: “How can predictive protein expression be solved?”.

59 BASIC BIOLOGICAL SCIENCES↗

The Uniform Methods Project: Smart Thermostat Evaluation Protocol

A smart thermostat is an internet-connected device that controls home heating, ventilation, and air-conditioning (HVAC) equipment and can automatically adjust temperature set points to optimize performance and achieve energy savings. Smart thermostat features often include two way communication, occupancy detection (such as geofencing and occupancy sensors), schedule learning, and seasonal optimization algorithms. Smart thermostats can control most conventional HVAC systems, including central air conditioners, heat pumps, and forced air furnaces. Several types of residential utility programs offer smart thermostats as replacements measures. Working with smart thermostat vendors, utilities can offer separate optimization programs to produce energy savings beyond those achieved by installing a smart thermostat. From an evaluation perspective, smart thermostat programs have several noteworthy features. First, the energy savings from a smart thermostat may change over the life of the device. As a smart thermostat is connected to the internet, original equipment manufacturers can update the thermostat software to improve the thermostat's energy efficiency. Likewise, users can adjust the thermostat settings and schedules over time in response to changes in weather, thermal comfort, energy prices, or preferences for energy efficiency. Additionally, many thermostat manufacturers offer seasonal optimization programs that recommend changes or make minor, automated adjustments to the thermostat settings to improve energy efficiency. These opt-in programs are now standard offerings for many smart thermostat manufacturers and provided at no additional cost to users. The potential for software updates and continuous optimization and the evolving nature of user interactions mean future energy savings may differ from first-year savings and the energy savings of smart thermostats may need to be evaluated more than once. Second, smart thermostats often have small unit energy savings relative to a home's total energy consumption, especially in comparison to whole- home retrofit programs. This can make it difficult to detect the smart thermostat savings in billing or advanced metering infrastructure (AMI) meter consumption data. For example, as cooling loads in many regions average about 20% of annual electricity consumption, smart thermostat savings of 10% of cooling energy use would equate to a 2% reduction in home electricity consumption. Evaluators should use regression analysis of whole-home billing consumption or advanced metering infrastructure (AMI) meter consumption data to evaluate smart thermostat savings because, as explained at greater length below , these data are usually available to evaluators and regression can control for the impacts of weather and other potentially confounding factors on a home's energy consumption. Finally, as with other energy efficiency programs, participation in smart thermostat programs is self-selective. As discussed at greater length below , smart thermostat participants tend to be, among other things, younger, higher-income, and more likely to adopt electric vehicles (EVs) and internet connected devices than nonparticipants. These differences are often unobservable to the evaluator and correlated with a home's energy consumption, creating the potential for bias in estimating savings. Due to the small unit savings of thermostats, errors and biases from self-selection that may not be very consequential when evaluating a whole- home retrofits (e.g., ±2% of home electricity consumption) can have a major impact when evaluating the savings and cost-effectiveness of smart thermostat programs. A percentage point change in the estimated savings could affect the cost-effectiveness of a program. This means it is important for evaluators to assess and to minimize the potential for error from selection bias in estimating smart thermostat program savings. The Uniform Methods Project provides model protocols for determining energy savings and demand reductions that result from specific energy efficiency measures implemented through state and utility programs. In most cases, the measure protocols are based on a particular option identified by the International Performance Verification and Measurement Protocol ; however, this work provides a more detailed approach to implementing that option. Each chapter is written by technical experts in collaboration with their peers, reviewed by industry experts, and subject to public review and comment. The UMP protocols can be used by utilities, program administrators, public utility commissions, evaluators, and other stakeholders for both program planning and evaluation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An Investigation of LES Wall Modeling for Rayleigh–Bénard Convection via Interpretable and Physics-Aware Feedforward Neural Networks with DNS

Abstract The traditional approach of using the Monin–Obukhov similarity theory (MOST) to model near-surface processes in large-eddy simulations (LESs) can lead to significant errors in natural convection. In this study, we propose an alternative approach based on feedforward neural networks (FNNs) trained on output from direct numerical simulation (DNS). To evaluate the performance, we conduct both a priori and a posteriori tests. In the a priori (offline) tests, we compare the statistics of the surface shear stress and heat flux, computed from filtered DNS input variables, to the stress and flux obtained from the filtered DNS. Additionally, we investigate the importance of various input features using the Shapley additive explanations value and the conditional average of the filter grid cells. In the a posteriori (online) tests, we implement the trained models in the System for Atmospheric Modeling (SAM) LES and compare the LES-generated surface shear stress and heat flux with those in the DNS. Our findings reveal that vertical velocity, a traditionally overlooked flow quantity, is one of the most important input features for determining the wall fluxes. Increasing the number of input features improves the a priori test results but does not always improve the model performance in the a posteriori tests because of the differences in input variables between the LES and DNS. Last, we show that physics-aware FNN models trained with logarithmic and scaled parameters can well extrapolate to more intense convection scenarios than in the training dataset, whereas those trained with primitive flow quantities cannot. Significance Statement The traditional near-surface turbulence model, based on a shear-dominated boundary layer flow, does not represent near-surface turbulence in natural convection. Using a feedforward neural network (FNN), we can construct a more accurate model that better represents the near-surface turbulence in various flows and reveals previously overlooked controlling factors and process interactions. Our study shows that the FNN-generated models outperform the traditional model and highlight the importance of the near-surface vertical velocity. Furthermore, the physics-aware FNN models exhibit the potential to extrapolate to convective flows of various intensities beyond the range of the training dataset, suggesting their broader applicability for more accurate modeling of near-surface turbulence.

54 ENVIRONMENTAL SCIENCES↗

ML-based Micro-CT SOFC Microstructure Models (from Kent 2026 Microstructural Augmentation paper)

Overview -------------------------- This repository contains datasets from the manuscript **"Enhanced Generalizability to Deep-Learning Quantification of 3D Microstructural Characteristics through Microstructurally Aware Augmentation of Scarce Data"** (*William F. Kent, Rochan Bajpai, Rachel C. Kurchin, William K. Epting, Harry W. Abernathy, Paul A. Salvador. Submitted 2026*). The methods are also described in the dissertation **Data Intensive Analysis of Solid Oxide Cell Microstructures** (*Doctoral dissertation, Carnegie Mellon University, 2025*). The datasets here are trained convolutional neural network (CNN) models for predicting key microstructural properties of solid oxide cell (SOC) electrodes from low-res, 2-channel 3D images, as well as some helpful code. The parameters for input images are provided in the paper. Sample data is provided in the file `Combined_anode_aug_dual_1k_examples` - that particular data was used to train `anode_all_aug.pth` and will work most accurately with that model. Please familiarize yourself with all caveats on accuracy and applicability, as detailed in the associated paper. Usage -------------------------- The basic usage is as follows, assuming `model_fn` is the path to the .pth file, and `X` is 2-channel input image(s) of the proper dimensions (either one image of shape `[2,12,24,24]`, or a batch of N input images of shape `[N,2,12,24,24]`): from CNN_inferencer import load_model_for_inference model = load_model_for_inference(model_fn) y_predicted = model(X) The model object automatically handles input scaling and output de-scaling based on the way the models were trained - in other words, pass in a 2-channel micro-CT image, and it will output microstructural property values in real units. ## Other model object attributes Note that model has useful attributes other than its forward pass model(X). * `model.output_descaler` - returns the output descaler object. Model does the de-scaling when generating inferences, but you may want to re-use this de-scaler on other values to e.g. compare predictions to ground truth from already-scaled training data. * `model.prop_names` - Gives the property names of the predicted y values, in order. Only exists if there's an output scaler as part of the model object, which there will be in the models provided here. ## Usage with sample data Here is a short script to use with the included sample data. from CNN_inferencer import display_predictions, load_model_for_inference, calculate_mape, parity_plot import h5py import numpy as np model_fn = 'anode_all_aug.pth' data_fn = 'Combined_anode_aug_dual_1k_examples.h5' N_samples = 200 figure_outdir = '.' model = load_model_for_inference(model_fn) with h5py.File(data_fn,'r') as f: XX = f['X'] #These are the 2-channel 3D images yy = f['y'] #These are the ground-truth microstructural properties, but they have been scaled for training - need to de-scale below N = XX.shape[0] #How many images total in the input data file #Run inferences on N_samples random samples from XX. #Run in a batch, much more efficient than one at a time. ii = np.random.choice(N,N_samples,replace=False) ii.sort() y_pred = model(XX[ii]) #Get the original/true (but normalized/scaled) values from the training dataset... #Because they were normalized, they are not in real units yet. So let's also de-scale them using model.output_scaler. y_true = model.output_scaler.transform(yy[ii]) #Let's display actual values for just 5 random ones for i in np.random.choice(N_samples,5,replace=False): display_predictions(y_true[i], y_pred[i], model.prop_names) #Make parity plots for each property (ground truth vs predicted values) #Also label each plot with the mean abs. percent error (MAPE) of the predicted values for i,key in enumerate(model.prop_names): mape = calculate_mape(y_true[:,i], y_pred[:,i]) parity_plot(y_true[:,i], y_pred[:,i], figure_outdir, key, extra_title=f' ({mape:.2f}% MAPE)')

3D microstructure↗

Innovating the next generation of commercial smart building software

Nearly 30% of commercial building energy use is wasted due to equipment faults and HVAC controls problems. The result is increased emissions, compromised comfort and productivity, and less reliable coordination of building power needs with a clean grid. The energy impact alone represents $17 billion in potential savings. Today’s smart building software provides a robust solution to address these operational deficiencies. Energy management and information systems (EMIS) are saving up to 9% on average, with two-year paybacks. They are being incorporated into energy management processes, commissioning services, and utility programs. As effective as they are, two barriers prevent even deeper benefits; limited personnel to fix problems once they are identified, and the expense and time to manually implement changes in control systems. In partnership with the research community, the EMIS industry is developing new capabilities to overcome these barriers. Moving beyond siloed products for either fault detection and diagnostics, or optimal control, these new capabilities empower users to not only automatically identify faults, but also to push corrective action, and control improvements to their buildings. In this paper, several areas for enhancements are documented: ‘one-time’ correction of faults such as setpoints, schedules, and economizer lockouts; short-term active testing for automated proportional integral derivative (PID) loop tuning and functional testing; and continuous supervisory control for demand flexibility and year-round efficiency. Results are presented from a pair of partner implementations out of a dozen providers integrating these enhancements into their products, including field tests from across the country, and insights into operator acceptance and integration into operations and maintenance practices.

Casillas, Armando↗