Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Human Errors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

Thrust Vector Control for Nuclear Thermal Rockets

Future space missions may use Nuclear Thermal Rocket (NTR) stages for human and cargo missions to Mars and other destinations. The vehicles are likely to require engine thrust vector control (TVC) to maintain desired flight trajectories. This paper explores requirements and concepts for TVC systems for representative NTR missions. Requirements for TVC systems were derived using 6 degree-of-freedom models of NTR vehicles. Various flight scenarios were evaluated to determine vehicle attitude control needs and to determine the applicability of TVC. Outputs from the models yielded key characteristics including engine gimbal angles, gimbal rates and gimbal actuator power. Additional factors such as engine thrust variability and engine thrust alignment errors were examined for impacts to gimbal requirements. Various technologies are surveyed for TVC systems for the NTR applications. A key factor in technology selection is the unique radiation environment present in NTR stages. Other considerations including mission duration and thermal environments influence the selection of optimal TVC technologies. Candidate technologies are compared to see which technologies, or combinations of technologies best fit the requirements for selected NTR missions. Representative TVC systems are proposed and key properties such as mass and power requirements are defined. The outputs from this effort can be used to refine NTR system sizing models, providing higher fidelity definition for TVC systems for future studies.

Ensworth, Clinton B. F.↗

Geant4 simulation for a study of a possible use of carbon ions pencil beam for the treatment of ocular melanomas with the active scanning system at CNAO Centre

The aim of this work is to validate the Geant4 application reproducing the CNAO (National Centre for Oncological Hadrontherapy) beamline and to study of a possible use of carbon ion pencil beams for the treatment of ocular melanomas at the CNAO Centre. The promising aspect of carbon ions radiotherapy for the treatment of this disease lies in its superior relative radiobiological effectiveness (RBE). The Monte Carlo Geant4 toolkit is used to simulate the complete CNAO extraction beamline, with the active and passive components along it. A human eye modeled detector, including a realistic target tumor volume, is used as target. Cross check with previous studies at CNAO using protons allows comparisons on possible benefits on using such a technique with respect to proton beams. Before the eye-detector irradiation a validation of the Geant4 simulation with CNAO experimental data is carried out with both carbon ions and protons. Important beam parameters such as the transverse FWHM and scanned radiation field 's uniformity are tested within the simulation and compared with experimental measurements at CNAO Centre. The physical processes involved in secondary particles generation by carbon ions and protons in the eye-detector are reproduced to take into account the additional dose to the primary beam given to irradiated eye's tissues. A study of beam shaping is carried out to produce a uniform 3D dose distribution (shaped on the tumor) by the use of a spread out Bragg peak. The eye-detector is then irradiated through a two dimensional transverse beam scan at different depths. In the use case the eye-detector is rotated of an angle of 40 deg. in the vertical direction, in order to mis-align the tumor from healthy tissues in front of it. The treatment uniformity on the tumor in the eye-detector is tested. For a more quantitative description of the deposited dose in the eye-detector and for the evaluation of the ratio between the dose deposited in the tumor and the other eye components, proton and carbon DVHs (Dose Volume Histograms) are compared. A high statistics simulated sample is used to minimize statistical errors. In the simulation a new particle generation method is developed in order to reproduce the experimental treatment plan by importing the DICOM RT-PLAN file, which contains all the information on the irradiation geometries and sequences (treatment plan parameters). Conclusions Even further validations must be done, the good results so far obtained by this work point out and confirm the possibility of using carbon ions delivered with active scanning beams to treat the ocular melanoma.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

PDF Entity Annotation Tool (PEAT)

While different text mining approaches – including the use of Artificial Intelligence (AI) and other machine based methods - continue to expand at a rapid pace, the tools used by researchers to create the labeled datasets required for training, modeling, and evaluation remain rudimentary. Labeled datasets contain the target attributes the machine is going to learn; for example, training an algorithm to delineate between images of a car or truck would generally require a set of images with a quantitative description of the underlying features of each vehicle type. Development of labeled textual data that can be used to build natural language machine learning models for scientific literature is not currently integrated into existing manual workflows used by domain experts. Published literature is rich with important information, such as different types of embedded text, plots, and tables that can all be used as inputs to train ML/natural language processing (NLP) models, when extracted and prepared in machine readable formats. Currently, both normalized data extraction of use to domain experts and extraction to support development of ML/NLP models are labor intensive and cumbersome manual processes. Automatic extraction of data and information from formats such as PDFs that are optimized for layout and human readability, not machine readability. The PDF (Portable Document Format) Entity Annotation Tool (PEAT) was developed with the goal of allowing users to annotate publications within their current print format, while also allowing those annotations to be captured in a machine-readable format. One of the main issues with traditional annotation tools is that they require transforming the PDF into plain text to facilitate the annotation process. While doing so lessens the technical challenges of annotating data, the user loses all structure and provenance that was inherent in the underlying PDF. Also, textual data extraction from PDFs can be an error prone process. Challenges include identifying sequential blocks of text and a multitude of document formats (multiple columns, font encodings, etc.). As a result of these challenges, using existing tools for development of NLP/ML models directly from PDFs is difficult because the generated outputs are not interoperable. We created a system that allows annotations to be completed on the original PDF document structure, with no plain text extraction. The result is an application that allows for easier and more accurate annotations. In addition, by including a feature that grants the user the ability to easily create a schema, we have developed a system that can be used to annotate text for different domain-centric schemas of relevance to subject matter experts. Different knowledge domains require distinct schemas and annotation tags to support machine learning.

97 MATHEMATICS AND COMPUTING↗

TH-E-17A-04: Geometric Validation of K-Space Self-Gated 4D-MRI Vs. 4D-CT Using A Respiratory Motion Phantom

Purpose: 4D-CT is often limited by motion artifacts, low temporal resolution, and poor phase-based target definition. We recently developed a novel k-space self-gated 4D-MRI technique with high spatial and temporal resolution. The goal here is to geometrically validate 4D-MRI using a MRI-CT compatible respiratory motion phantom and comparison to 4D-CT. Methods: 4D-MRI was acquired using 3T spoiled gradient echo-based 3D projection sequences. Respiratory phases were resolved using self-gated k-space lines as the motion surrogate. Images were reconstructed into 10 temporal bins with 1.56×1.56×1.56mm3. A MRI-CT compatible phantom was designed with a 23mm diameter ball target filled with highconcentration gadolinium(Gd) gel embedded in a 35×40×63mm3 plastic box stabilized with low-concentration Gd gel. The whole phantom was driven by an air pump. Human respiratory motion was mimicked using the controller from a commercial dynamic phantom (RSD). Four breathing settings (rates/depths: 10s/20mm, 6s/15mm, 4s/10mm, 3s/7mm) were scanned with 4D-MRI and 4D-CT (slice thickness 1.25mm). Motion ground-truth was obtained from input signals and real-time video recordings. Reconstructed images were imported into Eclipse(Varian) for target contouring. Volumes and target positions were compared with ground-truth. Initial human study was investigated on a liver patient. Results: 4D-MRI and 4D-CT scans for the different breathing cycles were reconstructed with 10 phases. Target volume in each phase was measured for both 4D-CT and 4D-MRI. Volume percentage difference for the 6.37ml target ranged from 6.67±5.33 to 11.63±5.57 for 4D-CT and from 1.47±0.52 to 2.12±1.60 for 4D-MRI. The Mann-Whitney U-test shows the 4D-MRI is significantly superior to 4D-CT (p=0.021) for phase-based target definition. Centroid motion error ranges were 1.35–1.25mm (4D-CT), and 0.31–0.12mm (4D-MRI). Conclusion: The k-space self-gated 4D-MRI we recently developed can accurately determine phase-based target volume while avoiding typical motion artifacts found in 4D-CT, and is being further studied for use in GI targeting and motion management. This work supported in part by grant 1R03CA173273-01.

60 APPLIED LIFE SCIENCES↗

Robust Fault Detection Using Robust Z1 Estimation and Fuzzy Logic

This research considers the application of robust Z(sub 1), estimation in conjunction with fuzzy logic to robust fault detection for an aircraft fight control system. It begins with the development of robust Z(sub 1) estimators based on multiplier theory and then develops a fixed threshold approach to fault detection (FD). It then considers the use of fuzzy logic for robust residual evaluation and FD. Due to modeling errors and unmeasurable disturbances, it is difficult to distinguish between the effects of an actual fault and those caused by uncertainty and disturbance. Hence, it is the aim of a robust FD system to be sensitive to faults while remaining insensitive to uncertainty and disturbances. While fixed thresholds only allow a decision on whether a fault has or has not occurred, it is more valuable to have the residual evaluation lead to a conclusion related to the degree of, or probability of, a fault. Fuzzy logic is a viable means of determining the degree of a fault and allows the introduction of human observations that may not be incorporated in the rigorous threshold theory. Hence, fuzzy logic can provide a more reliable and informative fault detection process. Using an aircraft flight control system, the results of FD using robust Z(sub 1) estimation with a fixed threshold are demonstrated. FD that combines robust Z(sub 1) estimation and fuzzy logic is also demonstrated. It is seen that combining the robust estimator with fuzzy logic proves to be advantageous in increasing the sensitivity to smaller faults while remaining insensitive to uncertainty and disturbances.

Curry, Tramone↗

Factors affecting the accuracy of near-infrared spectroscopy concentration calculations for focal changes in oxygenation parameters

Near-infrared spectroscopy (NIRS) can be used to noninvasively measure changes in the concentrations of oxy- and deoxyhemoglobin in tissue. We have previously shown that while global changes can be reliably measured, focal changes can produce erroneous estimates of concentration changes (NeuroImage 13 (2001), 76). Here, we describe four separate sources for systematic error in the calculation of focal hemoglobin changes from NIRS data and use experimental methods and Monte Carlo simulations to examine the importance and mitigation methods of each. The sources of error are: (1). the absolute magnitudes and relative differences in pathlength factors as a function of wavelength, (2). the location and spatial extent of the absorption change with respect to the optical probe, (3). possible differences in the spatial distribution of hemoglobin species, and (4). the potential for simultaneous monitoring of multiple regions of activation. We found wavelength selection and optode placement to be important variables in minimizing such errors, and our findings indicate that appropriate experimental procedures could reduce each of these errors to a small fraction (<10%) of the observed concentration changes.

Non-NASA Center↗

The relationship between perceived length and egocentric location in Muller-Lyer figures with one versus two chevrons

We examined the apparent dissociation of perceived length and perceived position with respect to the Muller-Lyer (M-L) illusion. With the traditional (two-chevron) figure, participants made accurate open-loop pointing responses at the endpoints of the shaft, despite the presence of a strong length illusion. This apparently non-Euclidean outcome replicated that of Mack, Heuer, Villardi, and Chambers (1985) and Gillam and Chambers (1985) and contradicts any theory of the M-L illusion in which mislocalization of shaft endpoints plays a role. However, when one of the chevrons was removed, a constant pointing error occurred in the predicted direction, as well as a strong length illusion. Thus, with one-chevron stimuli, perceived length and location were no longer completely dissociated. We speculated that the presence of two opposing chevrons suppresses the mislocalizing effects of a single chevron, especially for figures with relatively short shafts.

NASA Center ARC↗

Sitting in the Pilot's Seat; Optimizing Human-Systems Interfaces for Unmanned Aerial Vehicles

One of the pilot-machine interfaces (the forward viewing camera display) for an Unmanned Aerial Vehicle called the DROID (Dryden Remotely Operated Integrated Drone) will be analyzed for optimization. The goal is to create a visual display for the pilot that as closely resembles an out-the-window view as possible. There are currently no standard guidelines for designing pilot-machine interfaces for UAVs. Typically, UAV camera views have a narrow field, which limits the situational awareness (SA) of the pilot. Also, at this time, pilot-UAV interfaces often use displays that have a diagonal length of around 20". Using a small display may result in a distorted and disproportional view for UAV pilots. Making use of a larger display and a camera lens with a wider field of view may minimize the occurrences of pilot error associated with the inability to see "out the window" as in a manned airplane. It is predicted that the pilot will have a less distorted view of the DROID s surroundings, quicker response times and more stable vehicle control. If the experimental results validate this concept, other UAV pilot-machine interfaces will be improved with this design methodology.

Queen, Steven M.↗

Evaluation of Visualization Software

Visualization software is widely used in scientific and engineering research. But computed visualizations can be very misleading, and the errors are easy to miss. We feel that the software producing the visualizations must be thoroughly evaluated and the evaluation process as well as the results must be made available. Testing and evaluation of visualization software is not a trivial problem. Several methods used in testing other software are helpful, but these methods are (apparently) often not used. When they are used, the description and results are generally not available to the end user. Additional evaluation methods specific to visualization must also be developed. We present several useful approaches to evaluation, ranging from numerical analysis of mathematical portions of algorithms to measurement of human performance while using visualization systems. Along with this brief survey, we present arguments for the importance of evaluations and discussions of appropriate use of some methods.

Globus, Al↗

Quantification of Trace Chemicals Using Vehicle Cabin Atmosphere Monitor

A system to monitor the concentrations of trace chemicals in cabin atmosphere is one of the most critical components in long-duration human flight missions. The Vehicle Cabin Atmosphere Monitor (VCAM) is a miniature gas chromatograph mass spectrometer system to be used to detect and quantify trace chemicals in the International Space Station. We developed an autonomous computational process to quantify trace chemicals for use in VCAM. The process involves the design of a measured signal quantification scheme, the construction of concentration curves (i.e. the relationship between concentration and ion count measured by VCAM), the decision rule of applying high- or low-gain concentration curves, and the detection of saturation, low-signals, and outliers. When the developed quantification process is applied, the average errors of concentration for most of trace chemicals are found to be between 14% and 66%.

Lee, Seungwon↗

Space Research Project Management Can Benefit from Engineering Technology Selection Methods

Many engineering methods have been developed to help management select technology for a system design or further research. The simplest way to compare technologies is to use a checklist containing all the more or less important selection criteria, so that nothing is overlooked. The criteria usually include cost, safety, reliability and maintainability, and potential problems such as noise generation and microgravity sensitivity. The next step typically is to weight and score all the criteria. The process of weighting and scoring is helpful in bringing out different priorities and reaching a shared point of view. Group technology selection methods are designed to highlight initial disagreements and produce a shared consensus. Often a frank discussion led by management rather than decision analysts can be more effective. The final selection depends on management and engineering judgment and may include programmatic and organizational factors that are beyond the engineering checklist. The objective of engineering technology selection methods is to provide engineering information to assist management in making sound decisions. Project management and technology selection are assumed to use rational engineering analytic methods, but they often do not. The reason is that human insight, intuition, and “gut feel,” rather than logic, more frequently determine our decisions. Project selection and management are strongly influenced by nonrational psychological influences, which can produce unjustified confidence and determination. Nevertheless, there is a strong need for space projects to do rational project analysis and selection. Demonstrating a rational spirit is necessary for a scientific and technical organization. Professional ethics at its best requires an open, honest, and fair process, without damaging politics. Rational analysis can help improve good projects and avoid selecting bad ones. A sanity check using rational analysis guided by a checklist can help avoid egregious and damaging errors.

Jones, Harry W.↗

MRI of bone marrow in the distal radius: in vivo precision of effective transverse relaxation times

The effective transverse relaxation time T2* is influenced by the presence of trabecular bone, and can potentially provide a measure of bone density as well as bone structure. We determined the in vivo precision of T2* in repeated bone marrow measurements. The T2* measurements of the bone marrow of the distal radius were performed twice within 2 weeks in six healthy young volunteers using a modified water-presaturated 3D Gradient-Recalled Acquisition at Steady State (GRASS) sequence with TE 7, 10, 12, 20, and 30; TR 67; flip angle (FA) 90 degrees. An axial volume covering a length of 5.6 cm in the distal radius was measured. Regions of interest (ROIs) were determined manually and consisted of the entire trabecular bone cross-section extending proximally from the radial subchondral endplate. Reproducibility of T2* and area measurements was expressed as the absolute precision error (standard deviation [SD] in ms or mm2) or as the relative precision error (SD/mean x 100, or coefficient of variation [CV] in %) between the two-point measurements. Short-term precision of T2* and area measurements varied depending on section thickness and location of the ROI in the distal radius. Absolute precision errors for T2* times were between 1.3 and 2.9 ms (relative precision errors 3.8-9.5 %) and for area measurements between 20 and 55 mm2 (relative precision errors 5.1-16.4%). This MR technique for quantitative assessment of trabecular bone density showed reasonable reproducibility in vivo and is a promising future tool for the assessment of osteoporosis.

NASA Discipline Musculoskeletal↗

Probability effects on stimulus evaluation and response processes

This study investigated the effects of probability information on response preparation and stimulus evaluation. Eight subjects responded with one hand to the target letter H and with the other to the target letter S. The target letter was surrounded by noise letters that were either the same as or different from the target letter. In 2 conditions, the targets were preceded by a warning stimulus unrelated to the target letter. In 2 other conditions, a warning letter predicted that the same letter or the opposite letter would appear as the imperative stimulus with .80 probability. Correct reaction times were faster and error rates were lower when imperative stimuli confirmed the predictions of the warning stimulus. Probability information affected (a) the preparation of motor responses during the foreperiod, (b) the development of expectancies for a particular target letter, and (c) a process sensitive to the identities of letter stimuli but not to their locations.

Non-NASA Center↗

Design Concept for a Reusable/Propellantless MXER Tether Space Transportation System

The Momentum Exchange/Electrodynamic Reboost (MXER) tether facility is a transformational concept that significantly reduces the fuel requirements (and associated costs) in transferring payloads above low earth orbit (LEO). Facility reboost is accomplished without propellant by driving current against a voltage created by a conducting tether's interaction with the Earth's magnetic field (electrodynamic reboost). This system can be used for transferring a variety of payloads (scientific, cargo, and human space vehicles) to multiple destinations including geosynchronous transfer orbit, the Moon or Mars. MXER technology advancement requires development in two key areas: survivable, high tensile strength non-conducting tethers and reliable, lightweight payload catch/release mechanisms. Fundamental requirements associated with the MXER non-conducting strength tether and catch mechanism designs will be presented. Key requirements for the tether design include high specific-strength (tensile strength/material density), material survivability to the space environment (atomic oxygen and ultraviolet radiation), and structural survivability to micrometeoroid/orbital debris (MM/OD) impacts. The driving mechanism key,gequirements include low mass-to-capture-volume ratio, positional and velocity error tolerance, and operational reliability. Preliminary tether and catch mechanism design criteria are presented, which have been used as guidelines to "screen" and down-select initial concepts. Candidate tether materials and protective coatings are summarized along with their performance in simulated space environments (e.g., oxygen plasma, thermal cycling). A candidate catch mechanism design concept is presented along with examples of demonstration hardware.

McCandless, B., II↗

Orion Optical Navigation for Loss of Communication Lunar Return Contingencies

The Orion Crew Exploration Vehicle (CEV) will replace the Space Shuttle and serve as the next-generation spaceship to carry humans back to the Moon for the first time since the Apollo program. For nominal lunar mission operations, the Mission Control Navigation team will utilize radiometric measurements to determine the position and velocity of Orion and uplink state information to support Lunar return. However, in the loss of communications contingency return scenario, Orion must safely return the crew to the Earth's surface. The navigation design solution for this loss of communications scenario is optical navigation consisting of lunar landmark tracking in low lunar orbit and star- horizon angular measurements coupled with apparent planetary diameter for Earth return trajectories. This paper describes the optical measurement errors and the navigation filter that will process those measurements to support navigation for safe crew return.

Getchius, Joel↗

Neuro-Vestibular Examination During and Following Spaceflight (Vestibular Health)

BACKGROUND Adaptation to microgravity during spaceflight causes neurological disturbances that are either directly or indirectly mediated by the vestibular system. These disturbances can include space motion sickness, spatial disorientation, and cognitive impairment, as well as changes in head-eye coordination, vestibulo-ocular reflexes, and control of posture and locomotion. Otolith-mediated reflex gains appear to adapt rapidly during spaceflight and after landing. However, animal studies have shown that structural modifications of the vestibular sensory apparatus develop during long-duration spaceflight. To date, no studies have characterized the severity of vestibular syndromes experienced by astronauts as a function of the duration of spaceflight or whether the effects are caused by changes at the peripheral end organs, midbrain, cerebellum, or vestibular cortex. OBJECTIVES We are investigating temporal vestibular changes in crewmembers of short, 6-month, and one-year missions to identify trends in adaptation of vestibular health and performance in orbit and after landing. We are also differentiating between peripheral and central vestibular forms of vertigo and oculomotor disorders. METHODS Recordings of eye, head, and body movements, as well as subjective reports of perception of motion, are being used to determine the presence of abnormal eye movements, dysmetria, motion sickness symptoms, and illusions of motion during head or body movements. This includes characterization of temporal trends in central compensation for vestibular (otolith) asymmetry. In-flight examinations are being performed early in the mission (Flight Days 1 and 30) and once every 2-3 months thereafter. Postflight examinations are performed after return (R) from the mission on R+0, R+4, R+9, and R+30. The inflight and postflight motion sickness questionnaires are customized to support data sharing across related studies. Ground-based control testing has been performed on healthy volunteers(18 females, 14 males;38.6 ± 9.2 years) in the laboratory to estimate mean normative responses, and on patients with bilateral vestibulopathy (BVP) (17 females, 13 males; 60.6 ± 13.0 years) at the University of Caen. RESULTS As of September 2024, two crewmembers have completed all preflight, inflight, and postflight testing. Additional crewmembers are currently enrolled and data collection is currently ongoing. For ground testing, BVP patients performed similarly to previous postflight astronauts on R+0 in various walking performance tasks. Three additional body movement perception tasks have been tested. For the Triangle Completion Task, BVP patients had a larger mean angle of deviation and longer mean distance than healthy controls. For the Self-Rotation Task and Distance Perception Task, BVP patients had larger errors than healthy controls. These data suggest that vestibular deficiencies impact all aspects of body movement perception tested; whereas previous studies suggest that vestibular deficiencies are only associated with directional errors, not with overall trajectories/path lengths. These data will be compared to those of crewmembers during early postflight readaptation. RELEVANCE If the observed symptoms in crewmembers are more deleterious after the year-long missions than those documented after 6-month missions, then relevant countermeasures will be required to maintain the health and operational performance of astronauts during longer missions. Depending on the etiology of the vestibular syndrome revealed by these tests, countermeasures will be proposed based on vestibular rehabilitation therapies currently used in patients with vestibular disorders, such as habituation, gaze stabilization, and/or balance training exercises. ACKNOWLEDGEMENT This work is supported by NASA’s Human Research Program Human Health Countermeasures Element.

T R Macaulay↗

Innovating the next generation of commercial smart building software

Nearly 30% of commercial building energy use is wasted due to equipment faults and HVAC controls problems. The result is increased emissions, compromised comfort and productivity, and less reliable coordination of building power needs with a clean grid. The energy impact alone represents $17 billion in potential savings. Today’s smart building software provides a robust solution to address these operational deficiencies. Energy management and information systems (EMIS) are saving up to 9% on average, with two-year paybacks. They are being incorporated into energy management processes, commissioning services, and utility programs. As effective as they are, two barriers prevent even deeper benefits; limited personnel to fix problems once they are identified, and the expense and time to manually implement changes in control systems. In partnership with the research community, the EMIS industry is developing new capabilities to overcome these barriers. Moving beyond siloed products for either fault detection and diagnostics, or optimal control, these new capabilities empower users to not only automatically identify faults, but also to push corrective action, and control improvements to their buildings. In this paper, several areas for enhancements are documented: ‘one-time’ correction of faults such as setpoints, schedules, and economizer lockouts; short-term active testing for automated proportional integral derivative (PID) loop tuning and functional testing; and continuous supervisory control for demand flexibility and year-round efficiency. Results are presented from a pair of partner implementations out of a dozen providers integrating these enhancements into their products, including field tests from across the country, and insights into operator acceptance and integration into operations and maintenance practices.

Casillas, Armando↗

Unified Language Frontend for Physic-Informed AI/ML

Artificial intelligence and machine learning (AI/ML) are becoming important tools for scientific modeling and simulation as in several other fields such as image analysis and natural language processing. ML techniques can leverage the computing power available in modern systems and reduce the human effort needed to configure experiments, interpret and visualize results, draw conclusions from huge quantities of raw data, and build surrogates for physics based models. Domain scientists in fields like fluid dynamics, microelectronics and chemistry can automate many of their most difficult and repetitive tasks or improve the design times by use of the faster ML-surrogates. However, modern ML and traditional scientific highperformance computing (HPC) tend to use completely different software ecosystems. While ML frameworks like PyTorch and TensorFlow provide Python APIs, most HPC applications and libraries are written in C++. Direct interoperability between the two languages is possible but is tedious and error-prone. In this work, we show that a compiler-based approach can bridge the gap between ML frameworks and scientific software with less developer effort and better efficiency. We use the MLIR (multi-level intermediate representation) ecosystem to compile a pre-trained convolutional neural network (CNN) in PyTorch to freestanding C++ source code in the Kokkos programming model. Kokkos is a programming model widely used in HPC to write portable, shared-memory parallel code that can natively target a variety of CPU and GPU architectures. Our compiler-generated source code can be directly integrated into any Kokkosbased application with no dependencies on Python or cross-language interfaces.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗