At least 1,459 records · Page 81

Computational design of metamaterials with self contact

Inverse homogenization in combination with contact modeling, topology optimization and shape optimization is used to design metamaterials with optimized macroscopic response. The homogenization assumes length scale separation which allows the non-linear macroscopic behavior to be obtained by analyzing a single unit cell in a lattice structure. Self contact in the unit cell, which is modeled using a third medium contact method, is leveraged to obtain a complex homogenized response. The inverse homogenization problem is initially formulated as a topology optimization problem, where the macroscopic stress–strain behavior is tuned to our liking. However, it is well known that boundary phenomena are difficult to model in topology optimization and that interface modeling is crucial to accurately analyze contact. For that reason, the boundary representation of the topology optimized design is extracted and used as initial design in a subsequent shape optimization. The behaviors of our designs are verified by performing rigorous post-processing analyzes using conforming meshes and conventional contact formulations.

42 ENGINEERING↗

Investigation of an inhomogeneous turbulent mixing model for conditional moment closure applied to autoignition

The present paper examines the case of autoignition of high pressure methane jets in a shock tube over a range of pre-heated air temperatures in engine-relevant conditions. The two objectives of the present paper are: (i) to examine the effect of the inhomogeneous mixing model on the autoignition predictions relative to the results obtained using homogeneous mixing models and (ii) to see if the magnitude of the change can explain the discrepancy between the predictions of ignition delay previously obtained with homogeneous mixing models and the experimental data. The governing equation of the scalar dissipation rate is solved for transient conditions and two different formulations of the same model are tested and compared: one using the linear model for the conditional velocity and one including the gradient diffusion model. The predicted ignition kernel location and time delay over a range of pre-combustion air temperatures are compared with results obtained using two homogeneous turbulent mixing models and available experimental data. The profiles of conditional velocity and the conditional scalar dissipation rate are examined. Issues related to the conditional velocity model are discussed. It is found that the differences in the predictions are due to the mixing model only. The inhomogeneous model using the gradient conditional velocity model produces much larger ignition delays compared to the other models, whereas the inhomogeneous form including the linear model does not produce any significant differences. The effect of the turbulent inhomogeneous model is larger at high air temperatures and decreases with decreasing air temperatures. In comparison with the measured ignition delays, the inhomogeneous-Gradient model brings a small improvement at high air temperatures over the results from the turbulent homogeneous models. At low air temperatures, other parameters need to be investigated in order to bring the predicted ignition delays and locations within the experimental data scatter. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Temporal discounting in life cycle assessment: A critical review and theoretical framework

Temporal homogeneity of inventory data is one of the major problems in life cycle assessment (LCA). Addressing temporal homogeneity of life cycle inventory data is important in reducing the uncertainties and improving the reliability of LCA results. This paper attempts to present a critical review and discussion on the fundamental issues of temporal homogeneity in conventional LCA and propose a theoretical framework for temporal discounting in LCA. Theoretical perspectives for temporal discounting in life cycle inventory analysis are discussed first based on the key elements of a scientific mechanism for temporal discounting. Then generic procedures for performing temporal discounting in LCA is derived and proposed based on the nature of the LCA method and the identified key elements of a scientific temporal discounting method. A five-step framework is proposed and reported in details based on the technical methods and procedures needed to perform a temporal discounting in life cycle inventory analysis. Challenges and possible solutions are also identified and discussed for the technical procedure and scientific accomplishment of each step within the framework. - Highlights: • A critical review for temporal homogeneity problem of life cycle inventory data • A theoretical framework for performing temporal discounting on inventory data • Methods provided to accomplish each step of the temporal discounting framework.

54 ENVIRONMENTAL SCIENCES↗

Motion Interplay as a Function of Patient Parameters and Spot Size in Spot Scanning Proton Therapy for Lung Cancer

Purpose: To quantify the impact of respiratory motion on the treatment of lung tumors with spot scanning proton therapy. Methods and Materials: Four-dimensional Monte Carlo simulations were used to assess the interplay effect, which results from relative motion of the tumor and the proton beam, on the dose distribution in the patient. Ten patients with varying tumor sizes (2.6-82.3 cc) and motion amplitudes (3-30 mm) were included in the study. We investigated the impact of the spot size, which varies between proton facilities, and studied single fractions and conventionally fractionated treatments. The following metrics were used in the analysis: minimum/maximum/mean dose, target dose homogeneity, and 2-year local control rate (2y-LC). Results: Respiratory motion reduces the target dose homogeneity, with the largest effects observed for the highest motion amplitudes. Smaller spot sizes (σ ≈ 3 mm) are inherently more sensitive to motion, decreasing target dose homogeneity on average by a factor 2.8 compared with a larger spot size (σ ≈ 13 mm). Using a smaller spot size to treat a tumor with 30-mm motion amplitude reduces the minimum dose to 44.7% of the prescribed dose, decreasing modeled 2y-LC from 87.0% to 2.7%, assuming a single fraction. Conventional fractionation partly mitigates this reduction, yielding a 2y-LC of 71.6%. For the large spot size, conventional fractionation increases target dose homogeneity and prevents a deterioration of 2y-LC for all patients. No correlation with tumor volume is observed. The effect on the normal lung dose distribution is minimal: observed changes in mean lung dose and lung V{sub 20} are <0.6 Gy(RBE) and <1.7%, respectively. Conclusions: For the patients in this study, 2y-LC could be preserved in the presence of interplay using a large spot size and conventional fractionation. For treatments using smaller spot sizes and/or in the delivery of single fractions, interplay effects can lead to significant deterioration of the dose distribution and lower 2y-LC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Limited Impact of Setup and Range Uncertainties, Breathing Motion, and Interplay Effects in Robustly Optimized Intensity Modulated Proton Therapy for Stage III Non-small Cell Lung Cancer

Purpose: To investigate the impact of setup and range uncertainties, breathing motion, and interplay effects using scanning pencil beams in robustly optimized intensity modulated proton therapy (IMPT) for stage III non-small cell lung cancer (NSCLC). Methods and Materials: Three-field IMPT plans were created using a minimax robust optimization technique for 10 NSCLC patients. The plans accounted for 5- or 7-mm setup errors with ±3% range uncertainties. The robustness of the IMPT nominal plans was evaluated considering (1) isotropic 5-mm setup errors with ±3% range uncertainties; (2) breathing motion; (3) interplay effects; and (4) a combination of items 1 and 2. The plans were calculated using 4-dimensional and average intensity projection computed tomography images. The target coverage (TC, volume receiving 95% of prescribed dose) and homogeneity index (D{sub 2} − D{sub 98}, where D{sub 2} and D{sub 98} are the least doses received by 2% and 98% of the volume) for the internal clinical target volume, and dose indexes for lung, esophagus, heart and spinal cord were compared with that of clinical volumetric modulated arc therapy plans. Results: The TC and homogeneity index for all plans were within clinical limits when considering the breathing motion and interplay effects independently. The setup and range uncertainties had a larger effect when considering their combined effect. The TC decreased to <98% (clinical threshold) in 3 of 10 patients for robust 5-mm evaluations. However, the TC remained >98% for robust 7-mm evaluations for all patients. The organ at risk dose parameters did not significantly vary between the respective robust 5-mm and robust 7-mm evaluations for the 4 error types. Compared with the volumetric modulated arc therapy plans, the IMPT plans showed better target homogeneity and mean lung and heart dose parameters reduced by about 40% and 60%, respectively. Conclusions: In robustly optimized IMPT for stage III NSCLC, the setup and range uncertainties, breathing motion, and interplay effects have limited impact on target coverage, dose homogeneity, and organ-at-risk dose parameters.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Indentation Schmid factor and orientation dependence of nanoindentation pop-in behavior of NiAl single crystals

Instrumented nanoindentation techniques have been widely used to characterize the small-scale mechanical behavior of materials. The elastic-plastic transition during nanoindentation is often indicated by a sudden displacement burst (pop-in) in the measured load-displacement curve. In defect-free single crystals, the pop-in is believed to be the result of homogeneous dislocation nucleation because the maximum shear stress corresponding to the pop-in load approaches the theoretical strength of the materials and because the statistical distribution of pop-in stresses is consistent with what is expected for a thermally activated process of homogeneous dislocation nucleation. This paper investigates whether this process is affected by crystallography and stress components other than the resolved shear stress. A Stroh formalism coupled with the two-dimensional Fourier transformation is used to derive the analytical stress fields in elastically anisotropic solids under Hertzian contact, which allows the determination of an indentation Schmid factor, namely, the ratio of maximum resolved shear stress to the maximum contact pressure. Nanoindentation tests were conducted on B2-structured NiAl single crystals with different surface normal directions. This material was chosen because it deforms at room temperature by {110}<001> slip and thus avoids the complexity of partial dislocation nucleation. Good agreement is obtained between the experimental data and the theoretically predicted orientation dependence of pop-in loads based on the indentation Schmid factor. Pop-in load is lowest for indentation directions close to <111> and highest for those close to <001>. In nanoindentation, since the stress component normal to the slip plane is typically comparable in magnitude to the resolved shear stress, we find that the pressure sensitivity of homogeneous dislocation nucleation cannot be determined from pop-in tests. Our statistical measurements generally confirm the thermal activation model of homogeneous dislocation nucleation. That is, the extracted dependence of activation energy on resolved shear stress is almost the same for all the indentation directions considered in this study, except for those close to <001>. Because very high pop-in loads are measured for orientations close to <001>, which implies a large contact area at pop-in, there is a higher probability of activating pre-existing dislocations in these orientations, which may explain the discrepancy near <001>.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Impact of uranium oxide (UO 2 ) fuel with molybdenum (Mo) inserts on pressurized water reactor performance and safety

This work investigates nuclear reactor performance and safety characteristics of UO 2 with high thermal conductivity Mo insert structures by using multiphysics modeling techniques. Additionally, the purpose of this study is to use scoping analyses to quantify the impact of using Mo inserts from neutronic and heat transfer standpoints. Attention is given to reactor performance parameters, such as cycle length, maximum fuel temperature, temperature gradients in the fuel, and stored energy in the fuel. The finite-element code BISON and the Monte Carlo particle transport code Serpent were used to perform sensitivity analyses on the Mo insert geometry to optimize the insert design and inform larger scale modeling that required the homogenization of the UO 2 and Mo. Although BISON is often used as a fuel performance analysis tool, it is used in this context for heat transfer analysis only. Fuel performance optimization is outside the scope of the current study, but would be important for future work focused on this concept. The results showed that the insert had little impact on neutronic performance and that homogenizing the UO 2 and Mo was acceptable for reactor physics calculations. Reactivity temperature coefficients calculated using homogeneous UO 2 -Mo were shown to be relatively similar to UO 2 , but higher Mo content and 235 U enrichment can reduce the worth of soluble boron and control rods. The effect of insert geometry on heat transfer was much greater, and an approximately 15–20% difference in maximum fuel temperature was predicted between the best and worst performing heat transfer geometries. Furthermore, thermal conductivity calibration based on the finite element analysis results was performed to improve the accuracy of temperature predictions in reactor analysis models that homogenized the UO 2 -Mo fuel. Compared with UO 2 in a pressurized water reactor (PWR), the optimized UO 2 -Mo design increased the margin to fuel melt by 13–32% across the fuel cycle, but it requires the 235U enrichment to exceed 5% to match the cycle length of conventional UO 2 .

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A low-temperature synthetic route to ternary iron-manganese metal fluorides nanoparticles

Ternary metal fluoride Fe{sub x}Mn{sub 1−x}F{sub 2} (x = 0.00, 0.25, 0.50, 0.75, and 1.00), which is a potential cathode material for next-generation Li-ion batteries, were synthesized via a convenient, low-temperature, bottom-up solution-phase method. The lattice dimensions deduced from X-ray diffraction suggested formation of homogeneous solid solutions. With increasing Fe content, the morphology of the solid changed from cubic particles to dendritic, with an average particle size of 20–40 nm. The results suggested that this synthetic method constitutes a translatable route to large-scale production of ternary metal fluoride nanoparticles. - Graphical abstract: Homogeneous random solid solutions of ternary metal fluoride Fe{sub x}Mn{sub 1−x}F{sub 2} can be prepared by room temperature coprecipitation of precursors followed by drying and calcination at 350 °C. Display Omitted - Highlights: • Homogeneous ternary mixed metal iron-manganese fluoride Fe{sub x}Mn{sub 1−x}F{sub 2} nanoparticles prepared by room temperature coprecipitation and calcination. • Fe{sub x}Mn{sub 1−x}F{sub 2} nanoparticles form different morphology aggregates depending on the composition. • Lattice dimensions from X-ray diffraction suggested formation of homogeneous solid solutions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Synthesis of Pt/PEI-MWCNT composite materials on polyethyleneimine-functionalized MWNTs as supports

Graphical abstract: Schematic diagram for (a) the preparation of Pt/MWCNT functionalized with PEI and (b) TEM of Pt/PEI-MWCNT. Highlights: Black-Right-Pointing-Pointer We prepared Pt/PEI/MWCNT where MWCNT was first functionalized by PEI (polyethyleneimine) followed by Pt deposit onto it. Black-Right-Pointing-Pointer PEI functionalization provided high density homogeneous functional groups on MWCNT's sidewall. Black-Right-Pointing-Pointer Cationic PEI leads to homogeneous dispersion in solutions such as water and organic solvents. Black-Right-Pointing-Pointer Pt/PEI/MWCNT catalyst exhibits excellent electrocatalytic activity compared to that of Pt/MWCNT catalyst obtained with polyvinylpyrrolidine (PVP). -- Abstract: Composite materials with highly dispersed platinum (Pt) nanoparticles on multiwalled carbon nanotubes (MWCNTs), functionalized with polyethyleneimine (PEI) by a noncovalent method were prepared. The PEI-functionalization provided high density homogeneous functional groups on the MWCNTs' sidewalls for binding Pt nanoparticles. Cationic PEI leads to homogeneous dispersion in solutions such as water and organic solvents. The effects of a reducing agent on the Pt nanoparticles that form on the surfaces of the MWCNT were studied by varying the molar ratio of NaOH to H{sub 2}PtCl{sub 6}. These composite materials were characterized with transmission electron micrograph (TEM), X-ray diffractometer (XRD) and X-ray photoelectron spectroscopy (XPS). The Pt/PEI-MWCNT catalyst exhibits excellent electrocatalytic activity and compared with Pt/PVP-MWCNT catalysts obtained with polyvinylpyrrolidone (PVP). Finally, the cyclic voltammogram of methanol electrooxidation for Pt/PEI-MWCNT shows better tolerance to CO and methanol oxidation to CO{sub 2} than of Pt/PVP-MWCNT.

36 MATERIALS SCIENCE↗

The use of RapidArc volumetric-modulated arc therapy to deliver stereotactic radiosurgery and stereotactic body radiotherapy to intracranial and extracranial targets

Twenty-three targets in 16 patients treated with stereotactic radiosurgery (SRS) or stereotactic body radiotherapy (SBRT) were analyzed in terms of dosimetric homogeneity, target conformity, organ-at-risk (OAR) sparing, monitor unit (MU) usage, and beam-on time per fraction using RapidArc volumetric-modulated arc therapy (VMAT) vs. multifield sliding-window intensity-modulated radiation therapy (IMRT). Patients underwent computed tomography simulation with site-specific immobilization. Magnetic resonance imaging fusion and optical tracking were incorporated as clinically indicated. Treatment planning was performed using Eclipse v8.6 to generate sliding-window IMRT and 1-arc and 2-arc RapidArc plans. Dosimetric parameters used for target analysis were RTOG conformity index (CI{sub RTOG}), homogeneity index (HI{sub RTOG}), inverse Paddick Conformity Index (PCI), D{sub mean} and D5-D95. OAR sparing was analyzed in terms of D{sub max} and D{sub mean}. Treatment delivery was evaluated based on measured beam-on times delivered on a Varian Trilogy linear accelerator and recorded MU values. Dosimetric conformity, homogeneity, and OAR sparing were comparable between IMRT, 1-arc RapidArc and 2-arc RapidArc plans. Mean beam-on times {+-} SD for IMRT and 1-arc and 2-arc treatments were 10.5 {+-} 7.3, 2.6 {+-} 1.6, and 3.0 {+-} 1.1 minutes, respectively. Mean MUs were 3041, 1774, and 1676 for IMRT, 1-, and 2-arc plans, respectively. Although dosimetric conformity, homogeneity, and OAR sparing were similar between these techniques, SRS and SBRT fractions treated with RapidArc were delivered with substantially less beam-on time and fewer MUs than IMRT. The rapid delivery of SRS and SBRT with RapidArc improved workflow on the linac with these otherwise time-consuming treatments and limited the potential for intrafraction organ and patient motion, which can cause significant dosimetric errors. These clinically important advantages make image-guided RapidArc useful in the delivery of SRS and SBRT to intracranial and extracranial targets.

61 RADIATION PROTECTION AND DOSIMETRY↗

Evaluation of bolus electron conformal therapy compared with conventional techniques for the treatment of left chest wall postmastectomy in patients with breast cancer

Postmastectomy radiation (PMRT) lowers local-regional recurrence risk and improves survival in selected patients with breast cancer. The chest wall and lower axilla are technically challenging areas to treat with homogenous doses and normal tissue sparing. This study compares several techniques for PMRT to provide data to guide selection of optimal treatment techniques. Twenty-five consecutive left-sided patients treated postmastectomy were contoured using Radiation Therapy Oncology Group (RTOG) atlas guidelines then planned using 4 different PMRT techniques: opposed tangents with wedges (3-dimensional [3D] wedges), opposed tangents with field-in-field (FiF) modulation, 8-field intensity modulation radiotherapy (IMRT), and custom bolus electron conformal therapy (BolusECT, .decimal, Inc., Sanford, FL). Required planning target volume (PTV) coverage was held constant, and then dose homogeneity and normal tissue dose parameters were compared among the 4 techniques. BolusECT achieved clincally acceptable PTV coverage for 22 out of 25 cases. Compared with either tangential technique, IMRT and BolusECT provided the lowest heart V{sub 25} doses (3.3% ± 0.9% and 6.6% ± 3.2%, respectively with p < 0.0001). FiF had the lowest mean total lung dose (7.3 ± 1.1 Gy, with p = 0.0013), IMRT had the lowest total lung V{sub 20} (10.3% ± 1.6%, p < 0.0001), and BolusECT had the lowest mean heart dose (7.3 ± 2.0 Gy, p = 0.0002). IMRT provided the optimal dose homogeneity and normal tissue sparing compared with all other techniques for the cases in which BolusECT could not achieve acceptable PTV coverage. IMRT generally exposes contralateral breast and lung to slightly higher doses. Optimal PMRT technique depends upon patient anatomy. Patients whose maximal target volume depth is about 5.7 cm or less can be treated with BolusECT-assisted 12 or 15 MeV electron beams. At these energies, BolusECT has comparable dose-volume statistics as IMRT and lower heart V{sub 25} than opposed tangential beams. Patients with larger depths are best treated with IMRT, which provides significant advantages in both dose homogeneity and normal tissue sparing compared with all other techniques.

61 RADIATION PROTECTION AND DOSIMETRY↗

Treatment planning strategy for whole-brain radiotherapy with hippocampal sparing and simultaneous integrated boost for multiple brain metastases using intensity-modulated arc therapy

Purpose: To retrospectively evaluate the accuracy, plan quality and efficiency of intensity-modulated arc therapy (IMAT) for hippocampal sparing whole-brain radiotherapy (HS-WBRT) with simultaneous integrated boost (SIB) in patients with multiple brain metastases (m-BM). Materials and methods: A total of 5 patients with m-BM were retrospectively replanned for HS-WBRT with SIB using IMAT treatment planning. The hippocampus was contoured on diagnostic T1-weighted magnetic resonance imaging (MRI) which had been fused with the planning CT image set. The hippocampal avoidance zone (HAZ) was generated using a 5-mm uniform margin around the paired hippocampi. The m-BM planning target volumes (PTVs) were contoured on T1/T2-weighted MRI registered with the 3D planning computed tomography (CT). The whole-brain planning target volume (WB-PTV) was defined as the whole-brain tissue volume minus HAZ and m-BM PTVs. Highly conformal IMAT plans were generated in the Eclipse treatment planning system for Novalis-TX linear accelerator consisting of high-definition multileaf collimators (HD-MLCs: 2.5-mm leaf width at isocenter) and 6-MV beam. Prescription dose was 30 Gy for WB-PTV and 45 Gy for each m-BM in 10 fractions. Three full coplanar arcs with orbit avoidance sectors were used. Treatment plans were evaluated using homogeneity (HI) and conformity indices (CI) for target coverage and dose to organs at risk (OAR). Dose delivery efficiency and accuracy of each IMAT plan was assessed via quality assurance (QA) with a MapCHECK device. Actual beam-on time was recorded and a gamma index was used to compare dose agreement between the planned and measured doses. Results: All 5 HS-WBRT with SIB plans met WB-PTV D{sub 2%}, D{sub 98%}, and V{sub 30} {sub Gy} NRG-CC001 requirements. The plans demonstrated highly conformal and homogenous coverage of the WB-PTV with mean HI and CI values of 0.33 ± 0.04 (range: 0.27 to 0.36), and 0.96 ± 0.01 (range: 0.95 to 0.97), respectively. All 5 hippocampal sparing patients met protocol guidelines with maximum dose and dose to 100% of hippocampus (D{sub 100%}) less than 16 and 9 Gy, respectively. The dose to the optic apparatus was kept below protocol guidelines for all 5 patients. Highly conformal and homogenous radiosurgical dose distributions were achieved for all 5 patients with a total of 33 brain metastases. The m-BM PTVs had a mean HI = 0.09 ± 0.02 (range: 0.07 to 0.19) and a mean CI = 1.02 ± 0.06 (range: 0.93 to 1.2). The total number of monitor units (MU) was, on average, 1677 ± 166. The average beam-on time was 4.1 ± 0.4 minute . The IMAT plans demonstrated accurate dose delivery of 95.2 ± 0.6%, on average, for clinical gamma passing rate with 2%/2-mm criteria and 98.5 ± 0.9%, on average, with 3%/3-mm criteria. Conclusions: All hippocampal sparing plans were considered clinically acceptable per NRG-CC001 dosimetric compliance criteria. IMAT planning provided highly conformal and homogenous dose distributions for the WB-PTV and m-BM PTVs with lower doses to OAR such as the hippocampus. These results suggest that HS-WBRT with SIB is a clinically feasible, fast, and effective treatment option for patients with a relatively large numbers of m-BM lesions.

61 RADIATION PROTECTION AND DOSIMETRY↗

Nontraditional Catalyst Supports in Surface Organometallic Chemistry

The field of Surface Organometallic Chemistry (SOMC) aims to blend the positive attributes of homogeneous and heterogeneous catalysis. Significant insight into heterogeneous systems has been gained over the years through the synthesis, characterization, and application of well-defined surface organometallic catalysts, predominantly supported on silica and alumina. Considerable research efforts have focused on the application of homogeneous methods to the synthesis and characterization of these systems. Homogeneous catalysis has thrived on its ability to electronically and sterically tune ligands to yield desired reactivity and selectivity. Efforts in SOMC, however, have only recently turned to harnessing the stereoelectronic diversity of potential inorganic support materials beyond silica and alumina in order to exert similar control on the reactivity of the organometallic active site. The support material is intrinsically linked to electronic structure and reactivity of heterogeneous organometallic systems in the same way that ligands exert control over homogeneous catalyst systems. The ability to tune the reactivity of heterogeneous catalysts by changing the support is of great value, and it is anticipated that this will represent an area of significant growth in the field. In this Perspective, the use and future of nontraditional catalyst supports, such as sulfated metal oxides, modified silicas, and redox active supports are discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effects of Pore-Scale Heterogeneity and Transverse Mixing on Bacterial Growth in Porous Media

Microbial degradation of contaminants in the subsurface requires the availability of nutrients; this is impacted by porous media heterogeneity and the degree of transverse mixing. Two types of microfluidic pore structures etched into silicon wafers (i.e., micromodels), i) a homogeneous distribution of cylindrical posts and ii) aggregates of large and small cylindrical posts, were used to evaluate the impact of heterogeneity on growth of a pure culture (Delftia acidovorans) that degrades (R)-2-(2,4-dichlorophenoxy)propionate (R-2,4-DP). Following inoculation, dissolved O2 and R-2,4-DP were introduced as two parallel streams that mixed transverse to the direction of flow. In the homogeneous micromodel, biomass growth was uniform in pore bodies along the center mixing line, while in the aggregate micromodel, preferential growth occurred between aggregates and slower less dense growth occurred throughout aggregates along the center mixing line. The homogeneous micromodel had more rapid growth overall (2X), and more R-2,4-DP degradation (9.5%) than the aggregate pore structure (5.7%). Simulation results from a pore-scale reactive transport model indicate mass transfer limitations within aggregates along the center mixing line decreased overall reaction; hence, slower biomass growth rates relative to the homogeneous micromodel are expected. Results from this study contribute to a better understanding of the coupling between mass transfer, reaction rates, and biomass growth in complex porous media, and suggest successful implementation and analysis of bioremediation systems requires knowledge of subsurface heterogeneity.

09 BIOMASS FUELS↗

Scattering Studies of Hydrophobic Monomers in Liposomal Bilayers: An Expanding Shell Model of Monomer Distribution

Hydrophobic monomers partially phase separate from saturated lipids when loaded into lipid bilayers in amounts exceeding a 1:1 monomer/lipid molar ratio. This conclusion is based on the agreement between two independent methods of examining the structure of monomer-loaded bilayers. Complete phase separation of monomers from lipids would result in an increase in bilayer thickness and a slight increase in the diameter of liposomes. A homogeneous distribution of monomers within the bilayer would not change the bilayer thickness and would lead to an increase in the liposome diameter. The increase in bilayer thickness, measured by the combination of small-angle neutron scattering (SANS) and small-angle X-ray scattering (SAXS), was approximately half of what was predicted for complete phase separation. The increase in liposome diameter, measured by dynamic light scattering (DLS), was intermediate between values predicted for a homogeneous distribution and complete phase separation. Combined SANS, SAXS, and DLS data suggest that at a 1.2 monomer/lipid ratio approximately half of the monomers are located in an interstitial layer sandwiched between lipid sheets. These results expand our understanding of using self-assembled bilayers as scaffolds for the directed covalent assembly of organic nanomaterials. In particular, the partial phase separation of monomers from lipids corroborates the successful creation of nanothin polymer materials with uniform imprinted nanopores. Finally, pore-forming templates do not need to span the lipid bilayer to create a pore in the bilayer-templated films.

59 BASIC BIOLOGICAL SCIENCES↗

Climate Impacts of Ice Nucleation

[1] Several different ice nucleation parameterizations in two different General Circulation Models (GCMs) are used to understand the effects of ice nucleation on the mean climate state, and the Aerosol Indirect Effects (AIE) of cirrus clouds on climate. Simulations have a range of ice microphysical states that are consistent with the spread of observations, but many simulations have higher present-day ice crystal number concentrations than in-situ observations. These different states result from different parameterizations of ice cloud nucleation processes, and feature different balances of homogeneous and heterogeneous nucleation. Black carbon aerosols have a small (-0.06 Wm -2 ) and not statistically significant AIE when included as ice nuclei, for nucleation efficiencies within the range of laboratory measurements. Indirect effects of anthropogenic aerosols on cirrus clouds occur as a consequence of increasing anthropogenic sulfur emissions with different mechanisms important in different models. In one model this is due to increases in homogeneous nucleation fraction, and in the other due to increases in heterogeneous nucleation with coated dust. The magnitude of the effect is the same however. The resulting ice AIE does not seem strongly dependent on the balance between homogeneous and heterogeneous ice nucleation. Regional effects can reach several Wm -2 . Indirect effects are slightly larger for those states with less homogeneous nucleation and lower ice number concentration in the base state. The total ice AIE is estimated at 0.27 ± 0.10 Wm -2 (1σ uncertainty). Finally, this represents a 20% offset of the simulated total shortwave AIE for ice and liquid clouds of -1.6 Wm -2 .

climate↗

Is Shallow Convection Sensitive to Environmental Heterogeneities?

The key assumption underlying convection parameterizations is that rising plumes develop in a horizontally homogeneous environment. With this in mind, we investigate the impact of environmental cloud layer heterogeneities on shallow convection using large-eddy simulation that applies a master-slave methodology. In the master-slave approach, two independent sets of thermodynamic variables (master and slave) are driven by one dynamics (coupled with the master) to remove the impact of internal variability of the dynamical system considered. The two thermodynamic sets include either a realistic heterogeneous environment or an environment that is homogenized outside clouds. The key is that homogenization also excludes subsiding shells surrounding cumulus clouds. The results show a small impact of the homogenization on cloud field properties. Here, the physical explanation highlights the role of the subsiding shell shielding a shallow cumulus cloud from its environment.

58 GEOSCIENCES↗