Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Grid Generation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

Verification of an Icosahedral Grid for Strategic Center for Networking, Communications, and Integration User Interface Spatial Capabilities

Spatial communication analysis tools are incredibly useful resources to have when planning a space mission. Every single mission that leaves Earth needs a way to get its data back down and every mission's requirements on how that will get accomplished is different. Being able to analyze how existing assets can provide services independent of a specific mission can be key in that process. Most current commercial software packages contain spatial analysis capabilities but go about the analysis in a way that is not the most efficient and can skew the results provided. NASA's Space Communication and Navigation (SCaN) Center for Engineering Networks, Integration, and Communications (SCENIC) seeks to solve this problem and provide analysis capabilities using both internally developed and open-source software. This allows incredible flexibility, customization and hugely reduces licensing costs. Using MATLAB® and Orbit Determination Toolbox created by Goddard Space Flight Center (GSFC), SCENIC is able to perform many node-based functions currently. Analysis utilizing the spatial tools in SCENIC allows a meaningful analysis of the capability of communication network assets in a way not seen in current commercial software packages. This paper discusses the verification activities associated with generating the spatial grid point definition utilized in these analysis capabilities, within the SCENIC user interface (UI).

Jasper, Lindsey A.↗

Storm-DEPART (Damage Estimate Prediction and Recovery Tool)

Storm-DEPART (Damage Estimate Prediction and Restoration Tool): Each year hurricanes and tropical storms in the United States damage critical infrastructure assets, disrupt the services they provide, and cause millions to billions of dollars in economic impacts due to extended recovery times. The Storm-DEPART tool and analytical output enable more impactful data-driven decision-making capabilities and strengthen national-level disaster preparedness, response, and recovery. Storm-DEPART, built through multi-month collaboration between Entergy and INL, combines Entergy’s critical infrastructure inventory data with weather forecasts to predict damages to Electric utility’s assets due to natural disasters and the estimated recovery support needed, including time, materials, and resource allocation. In the event of an approaching hurricane, this innovative solution can assess potential damage to power generation capacity, transmission grids, distribution networks, and communications assets from wind bands, storm surge, and flooding. With more effective predictions, Entergy can more efficiently allocate resources to mitigate impacts and optimize recovery for customers. Storm-DEPART also allows Electric utilities the ability to apply a planning scenario and model expected damage to better inform infrastructure restoration needs leading to enhance system resiliency. The technology is fully transferrable to other electric utilities with the same damage estimating challenges. The INL team is working on the evolution of Storm-DEPART to include ice event damage prediction framework.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Opportunities and Challenges to Capturing Distributed Battery Value via Retail Utility Rates and Programs

Distributed battery deployment is increasing with advanced metering, control, and communication technologies, leaving electric utilities with an under-utilized, flexible grid resource in aggregate. Rates can reflect locational and temporal prices while utility incentive-based programs allow DERs to provide direct grid services. However, utilities must balance accurately reflecting dynamic grid conditions versus simple and feasible design that encourages customer participation. Currently, most rates and incentive-based programs are simple, but as penetration of DER and advanced controls increase, dynamic designs could become prevalent. Utilities could encourage providing multiple services to optimize distributed battery dispatch and value streams, however, challenges persist when stacking services across distribution and bulk systems. A DER committed to multiple discrete services concurrently necessitates coordination between operators and a clear hierarchy of commitments. One way to address this is to separate commitments by time or capacity. For services that follow cyclic, predictable patterns, or those that are peak driven with predictability, an operator could ensure sufficient state of charge for participation, leaving time where a distributed battery could otherwise provide different services by segmenting participation temporally. To provide continuous or unexpected services, a battery operator may use state of charge management to reserve some percentage of the battery and segment participation by capacity. Macroeconomic trends, load patterns, generation profiles, and grid configurations drive variation in value and the subsequent implications for utility offerings and how a customer might participate. As distributed battery adoption increases, both regulators and utilities will need to ensure no adverse grid impacts and encourage provision of societal value beyond the customer domain.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Storm-DEPART (Damage Estimate Prediction and Recovery Tool)

Storm-DEPART (Damage Estimate Prediction and Restoration Tool): Each year hurricanes and tropical storms in the United States damage critical infrastructure assets, disrupt the services they provide, and cause millions to billions of dollars in economic impacts due to extended recovery times. The Storm-DEPART tool and analytical output enable more impactful data-driven decision-making capabilities and strengthen national-level disaster preparedness, response, and recovery. Storm-DEPART, built through multi-month collaboration between Entergy and INL, combines Entergy’s critical infrastructure inventory data with weather forecasts to predict damages to Electric utility’s assets due to natural disasters and the estimated recovery support needed, including time, materials, and resource allocation. In the event of an approaching hurricane, this innovative solution can assess potential damage to power generation capacity, transmission grids, distribution networks, and communications assets from wind bands, storm surge, and flooding. With more effective predictions, Entergy can more efficiently allocate resources to mitigate impacts and optimize recovery for customers. Storm-DEPART also allows Electric utilities the ability to apply a planning scenario and model expected damage to better inform infrastructure restoration needs leading to enhance system resiliency. The technology is fully transferrable to other electric utilities with the same damage estimating challenges. The INL team is working on the evolution of Storm-DEPART to include ice event damage prediction framework.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Control and Service Life Extension of Accelerator's Anode Voltage Regulator

Accelerator's beam quality is highly affected by the anode voltage's stability. The accelerator examined in this study is an ion implantation accelerator which anode voltage is regulated by an electromechanical system shown in Fig 1. The system works by stepping down the input grid voltage to generate a high anode voltage of up to 2.5 kV through a motor generator. It was desired that the system be able to correct for disturbances and instabilities in the input voltage swiftly while minimizing overshoots and steady state errors. Moreover, it should maintain such capability satisfactorily despite of degradations. It was predicted that this adaptive capability would be limited to a certain extent where if degradations become too severe, system's performance would deteriorate considerably such that maintenance actions or component replacements are required. The mechanism to control anode voltage, estimate and extend the system's Remaining Useful Life (RUL) in an integrated manner is explored in this paper. (authors)

43 PARTICLE ACCELERATORS↗

Economic Analysis of a Novel Thermal Energy Storage System Using Solid Particles for Grid Electricity Storage: Preprint

As renewable power generation becomes the mainstream new-built energy source, energy storage will become an indispensable need to complement the uncertainty of renewable resources to firm the power supply. When phasing out fossil-fuel power plants to meet the carbon neutral utility target in the midcentury around the world, large capacity of energy storage will be needed to provide reliable grid power. The integration of renewable power and storage to support future carbon-free utility has several significant and positive impacts including expanding the renewable generation into the grid, improving the peak-load response, and balancing the electricity supply and demand. Long-duration energy storage (10–100 hours duration) can potentially complement the reduction of fossil-fuel baseload generation that otherwise would risk grid security when a large portion of grid power comes from variable renewable sources. Current energy storage methods based on pumped storage hydropower or batteries have many limitations. Thermal energy storage (TES) has unique advantages in scale and siting flexibility to provide grid-scale storage capacity. A particle-based TES system has promising cost and performance for the future growing energy storage needs. This paper introduces the system and components required for the particle TES to be technically and economically competitive. A technoeconomic analysis based on preliminary component designs and performance shows that the particle TES integrated with an efficient air-Brayton combined cycle power system can provide power for several days by low-cost, high-performance storage cycles. It addresses grid storage needs by enabling large-scale grid integration of intermittent renewables like wind and solar, thereby increasing their grid value. The design specifications and cost estimations of major components in a commercial scale system are presented in this paper. The cost model provides insights for further development and cost comparison with competing technologies.

27 ARPA - Advanced Research Projects Agency-Energy↗

Chapter 32 - Power Grid Resilience

The new energy paradigm is altering the current power grid trend from synchronous generator reliant system toward power-electronics-based distributed energy resources (DERs). The resilient operation of modern power grid is highly dependent upon cyber and physical reliable operation of DERs. Power grid resilience broadly refers to the ability of the grid to be robust to eventualities and singularities that may disrupt the continuity of reliable power flow. This could involve resilience related to the physical system but more recently, the focus on cyber resilience has been evolving rapidly especially given the burgeoning growth of distributed generation and power-electronics-based DERs under smart grid and given that such threats to reliable operation do not have to evolve localized to where the physical asset is. Commonly, in power grids dominated by DERS, control and energy management are structured at a multitime scale multilayer fashion: (i) primary control layer at microseconds time scale, (ii) secondary control layer at millisecond time scale, and (iii) tertiary control layer at seconds to minutes time scale. The cyber-related issues that may affect the power grid resilience can be introduced in through primary, secondary, and tertiary control layers. The failure of each of these control layers may impact the reliable and resilient operation of the overall network and cause widespread failures which leads to unintended blackouts. As such, this chapter focuses on cyber-related resilience issues in primary control layer, secondary control layer, tertiary control layer, wide area/utility control, and anomaly detection and resilient communication.

anomaly detection↗

Grid-Scale Ternary-Pumped Thermal Electricity Storage for Flexible Operation of Nuclear Power Generation under High Penetration of Renewable Energy Sources

In this work, the integration of a grid-scale ternary-Pumped Thermal Electricity Storage (t-PTES) with a nuclear power generation to enhance operation flexibility is assessed using physics-based models and digital real time simulation. A part of the electricity from the nuclear power generation is delivered to the grid, and the balance is used to power a heat pump that can be augmented by an auxiliary resistive load element to increase the charging rate of the thermal storage. This increases the thermal potential between hot and cold thermal stores (usually solid materials or molten salts inside large storage tanks). The thermal energy is transformed back into electricity by reversing the heat pump cycle. Different transient scenarios including startup, shutdown, and power change for grid-connected operation are simulated to determine the behavior of the hybrid nuclear-t-PTES system operating under variable loads that constitute a departure from conventional, baseload nuclear plant operation schemes. Ternary refers to the three modes operation: (i) heat pump (including heating coil), (ii) heat engine, and (iii) simultaneous operation of heat pump (including heating coil) and heat engine during changeover from pumping to generation or vice-versa. The controllability of t-PTES in the short timescales as a dynamic load is used to demonstrate operational flexibility of hybrid nuclear plants for flexible operation through advanced load management. The integration of t-PTES into nuclear power systems enhances the system flexibility and is an enabler for high penetration of renewable energy resources.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Probabilistic Data-Driven Method for Photovoltaic Pseudo-Measurement Generation in Distribution Systems

This paper presents a probabilistic data-driven method to model the uncertainty of distributed photovoltaic (PV) generation to enhance the observability of distribution grids with a high penetration of renewable resources. The proposed method employs a kernel density estimation (KDE) technique to develop the conditional probability density function (PDF) of PV outputs given the time of the day, using the measurement data from observed PV systems. Then time series of output power of unmeasured PV generators, located at the same grid, are generated according to the corresponding PDF and used as pseudo-measurements in distribution system state estimation (DSSE). The proposed model has been tested and verified using real PV data and utility networks.

Yuan, Yuxuan↗

Collection Efficiency and Ice Accretion Calculations for a Boeing 737-300 Inlet

Collection efficiency and ice accretion calculations have been made for a Boeing 737-300 inlet using a three-dimensional panel code, an adaptive grid code, the NASA Lewis LEWICE3D grid based ice accretion code. Flow solutions for the inlet were generated using the VSAERO panel code. Grids used in the ice accretion calculations were generated using the newly developed adaptive grid code ICEGRID3D. The LEWICE3D grid based ice accretion program was used to calculate impingement efficiency and ice shapes. Ice shapes typifying rime and mixed icing conditions were generated for a 30 minute hold condition. All calculations were performed on an SGI Power Challenge computer. The results have been compared to experimental flow and impingement data. In general, the calculated flow and collection efficiencies compared well with experiment, and the ice shapes looked reasonable and appeared representative of the rime and mixed icing conditions for which they were calculated.

Bidwell, Colin S.↗

Dramatic Demand Reduction In The Desert Southwest

This report summarizes a project that was funded to the University of Nevada Las Vegas (UNLV), with subcontractors Pulte Homes and NV Energy. The project was motivated by the fact that locations in the Desert Southwest portion of the US demonstrate very high peak electrical demands, typically in the late afternoons in the summer. These high demands often require high priced power to supply the needs, and the large loads can cause grid supply problems. An approach was proposed through this contact that would reduce the peak electrical demands to an anticipated 65% of what code-built houses of the similar size would have. It was proposed to achieve energy reduction through four approaches applied to a development of 185 homes in northwest part of Las Vegas named Villa Trieste. First, the homes would all be highly energy efficient. Secondly, each house would have a PV array installed on it. Third, an advanced demand response technique would be developed to allow the resident to have some control over the energy used. Finally, some type of battery storage would be used in the project. Pulte Homes designed the houses. The company considered initial cost vs. long-term savings and chose options that had relatively short paybacks. HERS (Home Energy Rating Service) ratings for the homes are approximately 43 on this scale. On this scale, code-built homes rate at 100, zero energy homes rate a 0, and Energy Star homes are 85. In addition a 1.764 Wp (peak Watt) rated PV array was used on each house. This was made up of solar shakes that were in visual harmony with the roofing material used. A demand response tool was developed to control the amount of electricity used during times of peak demand. While demand response techniques have been used in the utility industry for some time, this particular approach is designed to allow the customer to decide the degree of participation in the response activity. The temperature change in the residence can be decided by the residents by adjusting settings. In a sense the customer can choose between greater comfort and greater money savings during demand response circumstances. Finally a battery application was to be considered. Initially it was thought that a large battery (probably a sodium-sulfur type) would be installed. However, after the contract was awarded, it was determined that a single, centrally-located battery system would not be appropriate for many reasons, including that with the build out plan there would not be any location to put it. The price had risen substantially since the budget for the project was put together. Also, that type of battery has to be kept hot all the time, but its use was only sought for summer operation. Hence, individual house batteries would be used, and these are discussed at the end of this report. Many aspects of the energy use for climate control in selected houses were monitored before residents moved in. This was done both to understand the magnitude of the energy flows but also to have data that could be compared to the computer simulations. The latter would be used to evaluate various aspects of our plan. It was found that good agreement existed between actual energy use and computed energy use. Hence, various studies were performed via simulations. Performance simulations showed the impact on peak energy usage between a code built house of same size and shape compared to the Villa Trieste homes with and without the PV arrays on the latter. Computations were also used to understand the effect of varying orientations of the houses in this typical housing development, including the effect of PV electrical generation. Energy conservation features of the Villa Trieste homes decreased the energy use during peak times (as well as all others), but the resulting decreased peak occurred at about the same time as the code-built houses. Consideration of the PV generation decreases the grid energy use further during daylight hours, but did not extend long enough many days to decrease the peak. Hence, a demand response approach, as planned, was needed. With participation of the residents in the demand response program developed does enable the houses to reduce the peak demand between 66% and 72%, depending on the built years. This was addressed fully in the latter part the study and is described in the latter part of this report.

24 POWER TRANSMISSION AND DISTRIBUTION↗

On the Path to SunShot. Emerging Issues and Challenges in Integrating High Levels of Solar into the Electrical Generation and Transmission System

This report examines how the bulk power system may need to evolve to accommodate the increased photovoltaic (PV) penetration resulting from achievement of the U.S. Department of Energy's SunShot cost targets. The variable and uncertain nature of PV-generated electricity presents grid-integration challenges. For example, the changing net load associated with high midday PV generation and low electricity demand can create 'overgeneration' that requires curtailment of PV output and reduces PV's value and cost-competitiveness. Accommodating the changes in net load resulting from increased variable generation requires enhancements to a power system's 'flexibility,' or ability to balance supply and demand over multiple time scales through options including changes in system operation, flexible generation, reserves from solar, demand response, energy storage, and enhanced transmission and regional coordination. For utility-scale PV with a baseline SunShot levelized cost of electricity (LCOE) of 6 cents/kWh, increasing the annual energy demand met by solar energy from 10% to 20% would increase the marginal LCOE of PV from 6 cents/kWh to almost 11 cents/kWh in a California grid system with limited flexibility. However, increasing system flexibility could minimize solar curtailment and keep PV cost-competitive at penetrations at least as high as 25%. In the longer term, energy storage technologies--such as concentrating solar power with thermal energy storage--could facilitate the cost-effective integration of even higher PV penetration. Efficient deployment of the grid-flexibility options needed to maintain solar's value will require various innovations, from the development of communication, control, and energy storage technologies to the implementation of new market rules and operating procedures.

14 SOLAR ENERGY↗

Towards Adaptive Mesh Refinement for the Spectral Element Solver Nek5000

When performing computational fluid dynamics (CFD) simulations of complex flows, the a priori knowledge of the flow physics and the location of the dominant flow features are usually unknown. For this reason, the development of adaptive remeshing techniques is crucial for large-scale computational problems. Some work has been made recently to provide Nek5000 with adaptive mesh refinement (AMR) capabilities in order to facilitate the generation of the grid and push forward the limit in terms of problem size and complexity [10]. Nek5000 is an open-source, highly scalable and portable code based on the spectral element method (SEM) [4], which offers minimal dissipation and dispersion, high accuracy and exponential convergence. It is aimed at solving direct and large-eddy simulations of turbulent incompressible or low Mach-number flows with heat transfer and species transport. The approach chosen for adapting the mesh is the h-refinement method, where elements are split locally, which requires the relaxation of the conforming grid constraint currently imposed by Nek5000. Other challenges include the implementation of an efficient management of the grid as refinement is applied, the development of tools to localize the critical flow regions via error estimators and the extension of the current preconditioning strategy to non-conforming grids. In this paper, we present a new procedure to setup an algebraic multigrid solver used as part of the preconditioner for the pressure equation.

Offermans, N.↗

Comprehensive Evaluation of Fast-Response, Reynolds-Averaged Navier–Stokes, and Large-Eddy Simulation Methods Against High-Spatial-Resolution Wind-Tunnel Data in Step-Down Street Canyons

Three computational fluid dynamics (CFD) methods with different levels of flow-physics modelling are comprehensively evaluated against high-spatial-resolution wind-tunnel velocity data from step-down street canyons (i.e., a short building downwind of a tall building). The first method is a semi-empirical fast-response approach using the Quick Urban Industrial Complex (QUIC-URB) model. The second method solves the Reynolds-averaged Navier–Stokes (RANS) equations, and the third one utilizes a fully-coupled fluid-structure interaction large-eddy simulation (LES) model with a grid-turbulence inflow generator. Unlike typical point-by-point evaluation comparisons, here the entire two-dimensional wind-tunnel dataset is used to evaluate the dynamics of dominant flow topological features in the street canyon. Each CFD method is scrutinized for several geometric configurations by varying the downwind-to-upwind building-height ratio (H d /H u ) and street canyon-width to building-width aspect ratio (S / W) for inflow winds perpendicular to the upwind building front face. Disparities between the numerical results and experimental data are quantified in terms of their ability to capture flow topological features for different geometric configurations. Ultimately, all three methods qualitatively predict the primary flow topological features, including a saddle point and a primary vortex. But, the secondary flow topological features, namely an in-canyon separation point and secondary vortices, are only well represented by the LES method despite its failure for taller downwind building cases. Misrepresentation of flow-regime transitions, exaggeration of the coherence of recirculation zones and wake fields, and overestimation of downwards vertical velocity into the canyon are the main defects in QUIC-URB, RANS and LES results, respectively. All three methods underestimate the updrafts and, surprisingly, QUIC-URB outperforms RANS for the streamwise velocity component, while RANS is superior to QUIC-URB for the vertical velocity component in the street canyon.

58 GEOSCIENCES↗

Can a Coating Mitigate Molten Na Dendrite Growth in NaSICON Under High Current Density?

Alkali metals are among the most desirable negative electrodes for long duration energy storage due to their extremely high capacities. Currently, only high-temperature (>250 °C) batteries have successfully used alkali electrodes in commercial applications, due to limitations imposed by solid electrolytes, such as low conductivity at moderate temperatures and susceptibility to dendrites. Toward enabling the next generation of grid-scale, long duration batteries, we aim to develop molten sodium (Na) systems that operate with commercially attractive performance metrics including high current density (>100 mA cm –2 ), low temperature (<200 °C), and long discharge times (>12 h). In this work, we focus on the performance of NaSICON solid electrolytes in sodium symmetric cells at 110 °C. Specifically, we use a tin (Sn) coating on NaSICON to reduce interfacial resistance by a factor of 10, enabling molten Na symmetric cell operation with “discharge” durations up to 23 h at 100 mA cm –2 and 110 °C. Unidirectional galvanostatic testing shows a 70% overpotential reduction, and electrochemical impedance spectroscopy (EIS) highlights the reduction in interfacial resistance due to the Sn coating. Detailed scanning electron microscopy (SEM) and energy-dispersive spectroscopy (EDS) show that Sn-coated NaSICON enables current densities of up to 500 mA cm –2 at 110 °C by suppressing dendrite formation at the plating interface (Mode I). In conclusion, this analysis also provides a mechanistic understanding of dendrite formation at current densities up to 1000 mA cm –2 , highlighting the importance of effective coatings that will enable advanced battery technologies for long-term energy storage.

25 ENERGY STORAGE↗

A Measurement‐Model Fusion Approach for Improved Wet Deposition Maps and Trends

Abstract Air quality models provide spatial fields of wet deposition (WD) and dry deposition that explicitly account for the transport and transformation of emissions from thousands of sources. However, many sources of uncertainty in the air quality model including errors in emissions and meteorological inputs (particularly precipitation) and incomplete descriptions of the chemical and physical processes governing deposition can lead to bias and error in the simulation of WD. We present an approach to bias correct Community Multiscale Air Quality model output over the contiguous United States using observation‐based gridded precipitation data generated by the Parameter‐elevation Regressions on Independent Slopes Model and WD observations at the National Atmospheric Deposition Program National Trends Network sites. A cross‐validation analysis shows that the adjusted annual accumulated WD for NO 3 − , NH 4 + , and SO 4 2− from 2002 to 2012 has less bias and higher correlation with observed values than the base model output without adjustment. Temporal trends in observed WD are captured well by the adjusted model simulations across the entire contiguous United States. Consistent with previous trend analyses, WD NO 3 − and SO 4 2− are shown to decrease during this period in the eastern half of the United States, particularly in the Northeast, while remaining nearly constant in the West. Trends in WD of NH 4 + are more spatially and temporally heterogeneous, with some positive trends in the Great Plains and Central Valley of CA and slightly negative trends in the south.

54 ENVIRONMENTAL SCIENCES↗

Hybrid renewable energy systems

In the pursuit of ecologically sustainable and resilient energy systems, increasingly more attention is being devoted to a diversity of energy generation and storage methods. As the landscape of generation technology gains nuance and complexity, a wide-ranging set of technical questions has emerged, touching on topics that range from control and optimization of hybrid systems to finance and economic viability to multi-fidelity modeling and scientific machine learning. In the context of this special issue, hybrid renewable energy systems are any systems that consider the combined dynamics of more than one form of generation, storage, or grid subsystem. Research endeavors have delved into improving the flexibility of energy systems by utilizing existing resources, introducing novel operational strategies, deploying enhanced renewable forecasts, and exploring emerging technologies. In conclusion, the interconnection among various sectors has garnered heightened attention, not only due to the provision of additional tradable energy products but also for furnishing flexible headroom to system operators.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Engineering Li/Na selectivity in 12-Crown-4–functionalized polymer membranes

Significance Lithium is a key ingredient in batteries, which are integral components of next-generation automobiles, airplanes, grid energy storage, and electronic devices. Unfortunately, lithium extraction from natural sources is laborious, slow, and costly, motivating the search for more efficient isolation techniques. While polymeric membranes could reduce the cost of lithium recovery, current membrane materials lack sufficient lithium-ion selectivity. To address this challenge, we introduce a class of polymeric membranes that incorporate ion binding sites, which significantly increases the transport selectivity of LiCl over NaCl. These studies provide guidelines and practical considerations for incorporating specific interactants into polymers that mediate selective ion transport.

36 MATERIALS SCIENCE↗