Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Germanium”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

Evaporated Se x Te 1-x Thin Films with Tunable Bandgaps for Short-Wave Infrared Photodetectors

Semiconducting absorbers in high-performance short-wave infrared (SWIR) photodetectors and imaging sensor arrays are dominated by single-crystalline germanium and III-V semiconductors. However, these materials require complex growth and device fabrication procedures. In this work, thermally evaporated Se x Te 1- x alloy thin films with tunable bandgaps for the fabrication of high-performance SWIR photodetectors are reported. From absorption measurements, it is shown that the bandgaps of Se x Te 1- x films can be tuned continuously from 0.31 eV (Te) to 1.87 eV (Se). Owing to their tunable bandgaps, the peak responsivity position and photoresponse edge of Se x Te 1- x film-based photoconductors can be tuned in the SWIR regime. By using an optical cavity substrate consisting of Au/Al 2 O 3 to enhance its absorption near the bandgap edge, the Se 0.32 Te 0.68 film (an optical bandgap of ≈0.8 eV)-based photoconductor exhibits a cut-off wavelength at ≈1.7 μm and gives a responsivity of 1.5 AW -1 and implied detectivity of 6.5 × 10 10 cm Hz 1/2 W -1 at 1.55 μm at room temperature. Importantly, the nature of the thermal evaporation process enables the fabrication of Se 0.32 Te 0.68 -based 42 × 42 focal plane arrays with good pixel uniformity, demonstrating the potential of this unique material system used for infrared imaging sensor systems.

36 MATERIALS SCIENCE↗

Unique Role of GeO 2 as a Noninvasive Promoter of Nano‐Sized Zeolite Crystals

Abstract The synthesis of zeolites with nano‐sized dimensions is often limited to a narrow design space that conventionally relies upon the design of organics to direct hierarchical materials. Here, it is demonstrated that the addition of an inorganic modifier, germanium oxide (GeO 2 ), to a zeolite growth mixture directs the formation of crystals with ultrasmall dimensions. This effect is observed for zeolites ZSM‐11 and ZSM‐5 over a range of synthesis conditions wherein the role of GeO 2 in zeolite crystallization deviates from its typical function as a heteroatom. Notably, the final products contain trace amounts of Ge, which indicates the inorganic modifier does not compete for sites in the zeolite framework based on its formation of a discrete phase that enables GeO 2 recovery. Catalytic tests using the methanol‐to‐hydrocarbons reaction reveal significant enhancement in the performance of zeolite catalysts prepared with GeO 2 compared to reported examples of nano‐sized zeolites. These findings highlight a potentially generalizable and commercially viable synthesis method to reduce mass‐transport limitations in zeolites for diverse applications.

Chemistry↗

Enhanced Laser Damage Threshold in Optically Addressable Light Valves via Aluminum Nitride Photoconductors

Abstract Optically addressable light valves (OALVs) are specialized optical components utilized for spatial beam shaping in various laser‐based applications, including optics damage mitigation, and enhanced functionality in diode‐based additive manufacturing requiring high intensities. Current state‐of‐the‐art OALVs employ photoconductors such as Bismuth Silicon Oxide (BSO) or Bismuth Germanium Oxide (BGO), which suffer from limited laser‐induced damage thresholds (LiDT) and inadequate thermal conductivities, thus restricting their use in high peak and average power applications. Aluminum nitride (AlN), an emerging ultra‐wide band gap (UWBG) III–V semiconductor, offers promising optoelectronic properties and superior thermal conductivity (>300 Wm −1 K −1 at 298° K, compared to BSO's 3.29 Wm −1 K −1 ). In this study, the first AlN‐based OALVs are designed, fabricated, and experimentally demonstrated using commercially available single‐crystal AlN substrates. These AlN‐based OALVs have shown clear superiority over BSO and BGO‐based devices. Design considerations for OALVs incorporating UWBG photoconductors are discussed, and the photoresponsivity from defect‐mediated sub‐bandgap absorption in AlN crystals is verified as sufficient for OALVs operating under high light fluences. The optimum driving voltage for the AlN‐based OALV is determined to be ≈ 45 V pp at 100 Hz, achieving a transmittance of 91.3%, an extinction ratio (ER) of more than 100, and a 51:1 image contrast.

36 MATERIALS SCIENCE↗

Understanding the Reactivity of a Thin Li 1.5 Al 0.5 Ge 1.5 (PO 4 ) 3 Solid–State Electrolyte toward Metallic Lithium Anode

The thickness of solid-state electrolytes (SSEs) significantly affects the energy density and safety performance of all-solid-state lithium batteries. However, a sufficient understanding of the reactivity toward lithium metal of ultrathin SSEs (<100 μm) based on NASICON remains lacking. Herein, for the first time, a self-standing and ultrathin (70 μm) NASICON-type Li 1.5 Al 0.5 Ge 1.5 (PO 4 ) 3 (LAGP) electrolyte via a scalable solution process is developed, and X-ray photoelectron spectroscopy reveals that changes in LAGP at the metastable Li-LAGP interface during battery operation is temperature dependent. Severe germanium reduction and decrease in LAGP particle size are detected at the Li-LAGP interface at elevated temperature. As a result, oriented plating of lithium metal on its preferred (110) face occurs during in situ X-ray diffraction cycling.

25 ENERGY STORAGE↗

Wear measurement of highly cross-linked UHMWPE using a 7 Be tracer implantation technique

The very low wear rates achieved with the current highly cross-linked ultra-high molecular weight polyethylenes (UHMWPE) used in joint prostheses have proven to be difficult to measure accurately by gravimetry. Tracer methods are therefore being explored. The purpose of this study was to effect a proof-of-concept on the use of the radioactive tracer beryllium-7 (7Be) for the determination of wear in a highly cross-linked orthopedic UHMWPE. Three crosslinked and four conventional UHMWPE pins made from compression-molded GUR 1050, were activated with 109 to 1010 7Be nuclei using a new implantation setup that produced a homogenous distribution of implanted nuclei up to 8.5 μm below the surface. The pins were tested for wear in a six-station pin-on-flat apparatus for up to 7.1 million cycles (178 km). A Germanium gamma detector was employed to determine activity loss of the UHMWPE pins at preset intervals during the wear test. The wear of the cross-linked UHMWPE pins was readily detected and estimated to be 17 ± 3 μg/Mc. The conventional-to-cross-linked ratio of the wear rates was 13.1 ± 0.8, in the expected range for these materials. It was estimated that implantation reduced the average wear rate by approximately 20%, and the oxidative degradation damage from implantation was negligible. Future applications of this tracer technology may include the analysis of location-specific wear, such as loss of material in the post or backside of a tibial insert.

Wimmer, Markus A.↗

Techno-economic analysis of three different substrate removal and reuse strategies for III-V solar cells: Techno-economic analysis for III-V solar cells

The high cost of wafers suitable for epitaxial deposition of III-V solar cells has been a primary barrier to widespread use of these cells in low-concentration and one-sun terrestrial solar applications. A possible solution is to reuse the substrate many times, thus spreading its cost across many cells. We performed a bottom-up techno-economic analysis of three different strategies for substrate reuse in high-volume manufacturing: epitaxial lift-off, spalling, and the use of a porous germanium release layer. The analysis shows that the potential cost reduction resulting from substrate reuse is limited in all three strategies--not by the number of reuse cycles achievable, but by the costs that are incurred in each cycle to prepare the substrate for another epitaxial deposition. The dominant substrate-preparation cost component is different for each of the three strategies, and the cost-ranking of these strategies is subject to change if future developments substantially reduce the cost of epitaxial deposition.

14 SOLAR ENERGY↗

Atomic Structure and Dynamics of Unusual and Wide-Gap Phase-Change Chalcogenides: A GeTe 2 Case

Brain-inspired computing, reconfigurable optical metamaterials, photonic tensor cores, and many other advanced applications require next-generation phase-change materials (PCMs) with better energy efficiency and a wider thermal and spectral range for reliable operations. Germanium ditelluride (GeTe 2 ), with higher thermal stability and a larger bandgap compared to current benchmark PCMs, appears promising for THz metasurfaces and the controlled crystallization of atomically thin 2D materials. Using high-energy X-Ray diffraction supported by first-principles simulation, the atomic structure in semiconducting pulsed laser deposition films and metallic high-temperature liquids is investigated. The results suggest that the structural and chemical metastability of GeTe 2 , leading to disproportionation into GeTe and Te, is related to high internal pressure during a semiconductor–metal transition, presumably occurring in the supercooled melt. Similar phenomena are expected for canonical GeS 2 and GeSe 2 under high temperatures and pressures.

74 ATOMIC AND MOLECULAR PHYSICS↗

Site-Projected Thermal Conductivity: Application to Defects, Interfaces, and Homogeneously Disordered Materials

With the rapid advance of high-performance computing and electronic technologies, understanding thermal conductivity in materials has become increasingly important. This study presents a novel method: the site-projected thermal conductivity that quantitatively estimates the local (atomic) contribution to heat transport, leveraging the Green–Kubo thermal transport equations. The effectiveness of this approach on disordered and amorphous graphene, amorphous silicon, and grain boundaries in silicon–germanium alloys is demonstrated. Amorphous graphene reveals a percolation behavior for thermal transport. The results highlight the potential of the method to provide new insights into the thermal behavior of materials, offering a promising avenue for materials design and performance optimization.

36 MATERIALS SCIENCE↗

Unusually large 254 Atoms Counter‐Ion for 5 Atoms [Ge 5 ] 2– Cluster

Abstract . With the attempt to synthesize Nb‐enclosed germanium Zintl cluster ion in ethylenediamine ( en ) / toluene solution, the reaction of K 4 Ge 9 /Na 4 Ge 9 with Nb( mes ) 2 ( mes = mesitylene) gives unexpected 18‐crown‐6 cleavage product of [K 14 Na 2 (NbO 2 ) 2 (C 8 H 16 O 5 ) 8 ](Ge 5 ) ( en ) · solv in the form of very air‐sensitive, light‐brown, plate‐like crystals. This unique compound crystallizes in monoclinic Pn (No. 7) space group, the cleavage of crown linked the 14 potassium, 2 sodium, and 2 niobium atoms into the bulky 2+ charged cation, which balances the [Ge 5 ] 2– anion. This compound represents the rare example of heteronuclear metal alkoxide / Zintl ion hybrid.

Zavalij, Peter Y.↗

Direct detection of sub-GeV dark matter with semiconductor targets

Dark matter in the sub-GeV mass range is a theoretically motivated but largely unexplored paradigm. Such light masses are out of reach for conventional nuclear recoil direct detection experiments, but may be detected through the small ionization signals caused by dark matter-electron scattering. Semiconductors are well-studied and are particularly promising target materials because their O(1 eV) band gaps allow for ionization signals from dark matter particles as light as a few hundred keV. Current direct detection technologies are being adapted for dark matter-electron scattering. In this paper, we provide the theoretical calculations for dark matter-electron scattering rate in semiconductors, overcoming several complications that stem from the many-body nature of the problem. We use density functional theory to numerically calculate the rates for dark matter-electron scattering in silicon and germanium, and estimate the sensitivity for upcoming experiments such as DAMIC and SuperCDMS. We find that the reach for these upcoming experiments has the potential to be orders of magnitude beyond current direct detection constraints and that sub-GeV dark matter has a sizable modulation signal. We also give the first direct detection limits on sub-GeV dark matter from its scattering off electrons in a semiconductor target (silicon) based on published results from DAMIC. We make available publicly our code, QEdark, with which we calculate our results. Our results can be used by experimental collaborations to calculate their own sensitivities based on their specific setup. In conclusion, the searches we propose will probe vast new regions of unexplored dark matter model and parameter space.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Impact of form factor uncertainties on interpretations of coherent elastic neutrino-nucleus scattering data

The standard model coherent elastic neutrino-nucleus scattering (CEνNS) cross section is subject to nuclear form factor uncertainties, mainly driven by the root-mean-square radius of the neutron density distribution. Motivated by COHERENT phases I-III and future multi-ton direct detection dark matter searches, we evaluate these uncertainties in cesium iodide, germanium, xenon and argon detectors. We find that the uncertainties become relevant for momentum transfers q≳20 MeV and are essentially independent of the form factor parameterization. Consequently, form factor uncertainties are not important for CEνNS induced by reactor or solar neutrinos. Taking into account these uncertainties, we then evaluate their impact on measurements of CEνNS at COHERENT, the diffuse supernova background (DSNB) neutrinos and sub-GeV atmospheric neutrinos. We also calculate the relative uncertainties in the number of COHERENT events for different nuclei as a function of recoil energy. For DSNB and atmospheric neutrinos, event rates at a liquid argon detector can be uncertain to more than 5%. Finally, we consider the impact of form factor uncertainties on searches for nonstandard neutrino interactions, sterile neutrinos and neutrino generalized interactions. We point out that studies of new physics using CEνNS data are affected by neutron form factor uncertainties, which if not properly taken into account may lead to the misidentification of new physics signals. The uncertainties quantified here are also relevant for dark matter direct detection search

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

New physics versus quenching factors in Coherent Neutrino Scattering

Recent results on the Coherent Elastic Neutrino-Nucleus Scattering (CEνNS) on germanium present significant discrepancies among experiments. We perform a combined analysis of the Dresden-II, CONUS+ and COHERENT data, quantifying the impact of quenching factor uncertainties on their CEνNS cross section measurement. No choice of quenching factor can bring these three data sets into mutual agreement, whereas the combination of COHERENT with either Dresden-II or CONUS+ agrees well albeit for very different quenching factors. We further study the quenching factor dependence on the sensitivity of these experiments to a large neutrino magnetic moment, finding that the constraints can vary by up to an order of magnitude. Our work highlights the importance of reducing this uncertainty on quenching factors in order to probe new physics from neutrinos at the low-energy frontier.

neutrino interactions↗

Short-lived fission product measurements from >0.1 MeV neutron-induced fission using boron carbide.

A boron carbide shield was designed, custom fabricated, and used to create a fast fission energy neutron spectrum. The fissionable isotopes 233, 235, 238U, 237Np, and 239Pu were separately placed inside of this shield and irradiated under pulsed conditions at the Washington State University 1 MW TRIGA reactor. A unique set of fission product gamma spectra were collected at short times (4 minutes to 1 week) post-fission. Gamma spectra were collected on single-crystal high purity germanium detectors and on Pacific Northwest National Laboratory's (PNNL's) Direct Simultaneous Measurement (DSM) system composed of HPGe detectors connected in coincidence. This work defines the experimental methods used to produce and collect the gamma data, and demonstrates the validity of the measurements. It is important to fully document this information so the data can be used with high confidence for the advancement of nuclear science and non-proliferation applications. The gamma spectra collected in these and other experiments will be made publicly available at https://spcollab.pnl.gov/sites/gammadata or via the link at http://rdnsgroup.pnl.gov. A revised version of this publication will be posted with the data to make the experimental details available to those using the data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Identifying and quantifying short-lived fission products from thermal fission of HEU using portable HPGe detectors

Due to the emerging potential for trafficking of special nuclear material, research programs are investigating current capabilities of commercially available portable gamma ray detection systems. Presented in this paper are the results of three different portable high-purity germanium (HPGe) detectors used to identify short-lived fission products generated from thermal neutron interrogation of small samples of highly enriched uranium. Samples were irradiated at the Washington State University (WSU) Nuclear Radiation Center’s 1MW TRIGA reactor. The three portable, HPGe detectors used were the ORTEC MicroDetective, the ORTEC Detective, and the Canberra Falcon. Canberra’s GENIE-2000 software was used to analyze the spectral data collected from each detector. Ultimately, these three portable detectors were able to identify a large range of fission products showing potential for material discrimination.

detectors↗

Cumulative fission yields of short-lived isotopes under natural-abundance-boron-carbide-moderated neutron spectrum

The availability of gamma spectroscopy data on samples containing mixed fission products at short times after irradiation is limited. Due to this limitation, data interpretation methods for gamma spectra of mixed fission product samples, where the individual fission products have not been chemically isolated from interferences, are not well-developed. The limitation is particularly pronounced for fast pooled neutron spectra because of the lack of available fast reactors in the United States. Samples containing the actinide isotopes 233, 235, 238U, 237Np, and 239Pu individually were subjected to a 2$ pulse in the Washington State University 1 MW TRIGA reactor. To achieve a fission-energy neutron spectrum, the spectrum was tailored using a natural abundance boron carbide capsule to absorb neutrons in the thermal and epithermal region of the spectrum. Our tailored neutron spectrum is unique to the WSU reactor facility, consisting of a soft fission spectrum that contains some measurable flux in the resonance region. This results in a neutron spectrum at greater than 0.1 keV with an average energy of 70 keV, similar to fast reactor spectra and approaching that of 235U fission. Unique fission product gamma spectra were collected from 4 minutes to 1 week after fission using single-crystal high purity germanium detectors. Cumulative fission product yields measured in the current work generally agree with published fast pooled fission product yield values from ENDF/B-VII, though a bias was noted for 239Pu. The present work contributes to the compilation of energy-resolved fission product yield nuclear data for nuclear forensic purposes.

Finn, Erin C.↗

Reducing uncertainties for short lived cumulative fission product yields

Uncertainties associated with short lived (halflives less than 1 day) fission product yields listed in databases such as the National Nuclear Data Center’s ENDF/B-VII are large enough for certain isotopes to provide an opportunity for new precision measurements to offer significant uncertainty reductions. A series of experiments has begun where small samples of 235 U are irradiated with a pulsed, fission neutron spectrum at the Nevada National Security Site and placed between two broad-energy germanium detectors. The amount of various isotopes present immediately following the irradiation can be determined given the total counts and the calibrated properties of the detector system. The uncertainty on the fission yields for multiple isotopes has been reduced by nearly an order of magnitude.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Quality assurance of temporal variability of natural decay chain and neutron induced background for low-level NORM analysis

In this study, twenty-one high purity germanium (HPGe) background spectra were collected over 2 years at Los Alamos National Laboratory. A quality assurance methodology was developed to monitor spectral background levels from thermal and fast neutron flux levels and naturally occurring radioactive material decay series radionuclides. 238 U decay products above 222 Rn demonstrated minimal temporal variability beyond that expected from counting statistics. 238 U and 232 Th progeny below Rn gas displayed at most twice the expected variability. Further, an analysis of the 139 keV 74 Ge(n, γ) and 691 keV 72 Ge(n, n') spectral features demonstrated temporal stability for both thermal and fast neutron fluxes.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Assay Methods for 238U, 232Th, and 210Pb in Lead and Calibration of 210Bi Bremsstrahlung Emission from Lead

Assay methods for measuring 238U, 232Th, and 210Pb concentrations in refined lead are presented. The 238U and 232Th concentrations are assayed via inductively coupled plasma mass spectrometry (ICP-MS) after anion exchange column separation on dissolved lead samples. The 210Pb concentration is inferred through α-spectroscopy of a daughter isotope, 210Po, after chemical precipitation separation on dissolved lead samples. Subsequent to the 210Po α-spectroscopy assay, a method for evaluating 210Pb concentrations in solid lead samples was developed via measurement of bremsstrahlung radiation from β-decay of a daughter isotope, 210Bi, by employing a 14-crystal array of high purity germanium (HPGe) detectors. Ten sources of refined lead were assayed. The 238U concentrations were <34 microBq/kg and the 232Th concentrations ranged <0.6 – 15 microBq/kg, as determined by the ICP-MS assay method. The 210Pb concentrations ranged from ~0.1 – 75 Bq/kg, as inferred by the 210Po α-spectroscopy assay method.

Orrell, John L.↗