Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Error analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

Multi defect detection and analysis of electron microscopy images with deep learning

Electron microscopy is widely used to explore defects in crystal structures, but human detecting of defects is often time-consuming, error-prone, and unreliable, and is not scalable to large numbers of images or real-time analysis. In this work, we discuss the application of machine learning approaches to find the location and geometry of different defect clusters in irradiated steels. We show that a deep learning based Faster R-CNN analysis system has a performance comparable to human analysis with relatively small training data sets. Furthermore, this study proves the promising ability to apply deep learning to assist the development of automated microscopy data analysis even when multiple features are present and paves the way for fast, scalable, and reliable analysis systems for massive amounts of modern electron microscopy data.

36 MATERIALS SCIENCE↗

The Simulation and Design of an On-Chip Superconducting Millimetre Filter-Bank Spectrometer

Abstract Superconducting on-chip filter banks provide a scalable, space saving solution to create imaging spectrometers at millimetre and submillimetre wavelengths. We present an easy to realise, lithographed superconducting filter design with a high tolerance to fabrication error. Using a capacitively coupled $$\lambda /2$$ λ / 2 microstrip resonator to define a narrow ( $$\lambda /\Delta \lambda = 300$$ λ / Δ λ = 300 ) spectral pass band, the filtered output of a given spectrometer channel directly connects to a lumped-element kinetic inductance detector. We show the tolerance analysis of our design, demonstrating $$<11\%$$ < 11 % change in filter quality factor to any one realistic fabrication error and a full filter-bank efficiency forecast to be 50% after accounting for fabrication errors and dielectric loss tangent.

Robson, G. (ORCID:0000000315279326)↗

Magnetic Resonance Imaging–Guided versus Surrogate-Based Motion Tracking in Liver Radiation Therapy: A Prospective Comparative Study

Purpose: This study applied automatic feature detection on cine–magnetic resonance imaging (MRI) liver images in order to provide a prospective comparison between MRI-guided and surrogate-based tracking methods for motion-compensated liver radiation therapy. Methods and Materials: In a population of 30 subjects (5 volunteers plus 25 patients), 2 oblique sagittal slices were acquired across the liver at high temporal resolution. An algorithm based on scale invariant feature transform (SIFT) was used to extract and track multiple features throughout the image sequence. The position of abdominal markers was also measured directly from the image series, and the internal motion of each feature was quantified through multiparametric analysis. Surrogate-based tumor tracking with a state-of-the-art external/internal correlation model was simulated. The geometrical tracking error was measured, and its correlation with external motion parameters was also investigated. Finally, the potential gain in tracking accuracy relying on MRI guidance was quantified as a function of the maximum allowed tracking error. Results: An average of 45 features was extracted for each subject across the whole liver. The multi-parametric motion analysis reported relevant inter- and intrasubject variability, highlighting the value of patient-specific and spatially-distributed measurements. Surrogate-based tracking errors (relative to the motion amplitude) were were in the range 7% to 23% (1.02-3.57mm) and were significantly influenced by external motion parameters. The gain of MRI guidance compared to surrogate-based motion tracking was larger than 30% in 50% of the subjects when considering a 1.5-mm tracking error tolerance. Conclusions: Automatic feature detection applied to cine-MRI allows detailed liver motion description to be obtained. Such information was used to quantify the performance of surrogate-based tracking methods and to provide a prospective comparison with respect to MRI-guided radiation therapy, which could support the definition of patient-specific optimal treatment strategies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

THE DISCOVERY OF HD 37605c AND A DISPOSITIVE NULL DETECTION OF TRANSITS OF HD 37605b

We report the radial velocity discovery of a second planetary mass companion to the K0 V star HD 37605, which was already known to host an eccentric, P {approx} 55 days Jovian planet, HD 37605b. This second planet, HD 37605c, has a period of {approx}7.5 years with a low eccentricity and an Msin i of {approx}3.4 M{sub Jup}. Our discovery was made with the nearly 8 years of radial velocity follow-up at the Hobby-Eberly Telescope and Keck Observatory, including observations made as part of the Transit Ephemeris Refinement and Monitoring Survey effort to provide precise ephemerides to long-period planets for transit follow-up. With a total of 137 radial velocity observations covering almost 8 years, we provide a good orbital solution of the HD 37605 system, and a precise transit ephemeris for HD 37605b. Our dynamic analysis reveals very minimal planet-planet interaction and an insignificant transit time variation. Using the predicted ephemeris, we performed a transit search for HD 37605b with the photometric data taken by the T12 0.8 m Automatic Photoelectric Telescope (APT) and the MOST satellite. Though the APT photometry did not capture the transit window, it characterized the stellar activity of HD 37605, which is consistent of it being an old, inactive star, with a tentative rotation period of 57.67 days. The MOST photometry enabled us to report a dispositive null detection of a non-grazing transit for this planet. Within the predicted transit window, we exclude an edge-on predicted depth of 1.9% at the >>10{sigma} level, and exclude any transit with an impact parameter b > 0.951 at greater than 5{sigma}. We present the BOOTTRAN package for calculating Keplerian orbital parameter uncertainties via bootstrapping. We made a comparison and found consistency between our orbital fit parameters calculated by the RVLIN package and error bars by BOOTTRAN with those produced by a Bayesian analysis using MCMC.

79 ASTRONOMY AND ASTROPHYSICS↗

Preliminary Studies for a CBCT Imaging Protocol for Offline Organ Motion Analysis: Registration Software Validation and CTDI Measurements

Cone-beam X-ray volumetric imaging in the treatment room, allows online correction of set-up errors and offline assessment of residual set-up errors and organ motion. In this study the registration algorithm of the X-ray volume imaging software (XVI, Elekta, Crawley, United Kingdom), which manages a commercial cone-beam computed tomography (CBCT)-based positioning system, has been tested using a homemade and an anthropomorphic phantom to: (1) assess its performance in detecting known translational and rotational set-up errors and (2) transfer the transformation matrix of its registrations into a commercial treatment planning system (TPS) for offline organ motion analysis. Furthermore, CBCT dose index has been measured for a particular site (prostate: 120 kV, 1028.8 mAs, approximately 640 frames) using a standard Perspex cylindrical body phantom (diameter 32 cm, length 15 cm) and a 10-cm-long pencil ionization chamber. We have found that known displacements were correctly calculated by the registration software to within 1.3 mm and 0.4{sup o}. For the anthropomorphic phantom, only translational displacements have been considered. Both studies have shown errors within the intrinsic uncertainty of our system for translational displacements (estimated as 0.87 mm) and rotational displacements (estimated as 0.22{sup o}). The resulting table translations proposed by the system to correct the displacements were also checked with portal images and found to place the isocenter of the plan on the linac isocenter within an error of 1 mm, which is the dimension of the spherical lead marker inserted at the center of the homemade phantom. The registration matrix translated into the TPS image fusion module correctly reproduced the alignment between planning CT scans and CBCT scans. Finally, measurements on the CBCT dose index indicate that CBCT acquisition delivers less dose than conventional CT scans and electronic portal imaging device portals. The registration software was found to be accurate, and its registration matrix can be easily translated into the TPS and a low dose is delivered to the patient during image acquisition. These results can help in designing imaging protocols for offline evaluations.

61 RADIATION PROTECTION AND DOSIMETRY↗

PDE-constrained high-order mesh optimization

Here, we present a novel framework for PDE-constrained r-adaptivity of high-order meshes. The proposed method formulates mesh movement as an optimization problem, with an objective function defined as a convex combination of a mesh quality metric and a measure of the accuracy of the PDE solution obtained via finite element discretization. The proposed formulation achieves optimized, well-defined high-order meshes by integrating mesh quality control, PDE solution accuracy, and robust gradient regularization. We adopt the Target-Matrix Optimization Paradigm to control geometric properties across the mesh, independent of the PDE of interest. To incorporate the accuracy of the PDE solution, we introduce error measures that control the finite element discretization error. The implicit dependence of these error measures on the mesh nodal positions is accurately captured by adjoint sensitivity analysis. Additionally, a convolution-based gradient regularization strategy is used to ensure stable and effective adaptation of high-order meshes. We demonstrate that the proposed framework can improve mesh quality and reduce the error by up to 10 times for the solution of Poisson and linear elasto-static problems. The approach is general with respect to the dimensionality, the order of the mesh, the types of mesh elements, and can be applied to any PDE that admits well-defined adjoint operators.

Computer science↗

Clinical analysis of the approximate, 3-dimensional, biological effective dose equation in multiphase treatment plans

A multiphase, approximate biological effective dose (BED{sub A}) equation was introduced because most treatment planning systems (TPS) are incapable of calculating the true BED (BED{sub T}). This work investigates the accuracy and precision of the multiphase BED{sub A} relative to the BED{sub T} in clinical cases. Ten patients with head and neck cancer and 10 patients with prostate cancer were studied using their treatment plans from Pinnacle{sup 3} 9.2 (Philips Medical, Fitchburg, WI). The organs at risk (OARs) that were studied are the normal brain, left and right optic nerves, optic chiasm, spinal cord, brainstem, bladder, and rectum. BED{sub A} and BED{sub T} distributions were calculated using MATLAB 2010b (MathWorks, Natick, MA) and analyzed on a voxel basis for percent error, percent error volume histograms (PEVHs), Pearson correlation coefficient, and Bland-Altman analysis. The maximum BED values that were calculated using the BED{sub A} and BED{sub T} methods were also analyzed. BED{sub A} was found to always underestimate BED{sub T}. The accuracy and precision of BED{sub A} distributions varied between the organs: for optic chiasm and brainstem, 50% of the patients had an overall BED{sub A} percent error of A percent error of A percent error of A distributions had maximum errors ranging from 2% to 11%, with the 11% error occurring for bladder. BED{sub A} produced much more accurate maximum BED values with adjacent organs such as normal brain, bladder, and rectum. This study has shown that BED{sub A} can calculate BED distributions with acceptable accuracy under certain circumstances. However, its consistency and accuracy strongly depend on the dose distributions of the different treatment phases. One should be cautious when using BED{sub A}.

61 RADIATION PROTECTION AND DOSIMETRY↗

Analysis and validation of carbohydrate three-dimensional structures

The article summarizes the information that is gained from and the errors that are found in carbohydrate structures in the Protein Data Bank. Validation tools that can locate these errors are described. Knowledge of the three-dimensional structures of the carbohydrate molecules is indispensable for a full understanding of the molecular processes in which carbohydrates are involved, such as protein glycosylation or protein–carbohydrate interactions. The Protein Data Bank (PDB) is a valuable resource for three-dimensional structural information on glycoproteins and protein–carbohydrate complexes. Unfortunately, many carbohydrate moieties in the PDB contain inconsistencies or errors. This article gives an overview of the information that can be obtained from individual PDB entries and from statistical analyses of sets of three-dimensional structures, of typical problems that arise during the analysis of carbohydrate three-dimensional structures and of the validation tools that are currently available to scientists to evaluate the quality of these structures.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

LTAU-FF: Loss Trajectory Analysis for Uncertainty in atomistic Force Fields

Model ensembles are effective tools for estimating prediction uncertainty in deep learning atomistic force fields. However, their widespread adoption is hindered by high computational costs and overconfident error estimates. In this work, we address these challenges by leveraging distributions of per-sample errors obtained during training and employing a distance-based similarity search in the model latent space. Our method, which we call LTAU (Loss Trajectory Analysis for Uncertainty), efficiently estimates the full probability distribution function of errors for any test point using the logged training errors, achieving speeds that are 2–3 orders of magnitudes faster than typical ensemble methods and allowing it to be used for tasks where training or evaluating multiple models would be infeasible. We apply LTAU towards estimating parametric uncertainty in atomistic force fields (LTAU-FF), demonstrating that it produces well-calibrated confidence intervals and predicts errors that correlate strongly with the true errors for data near the training domain. Furthermore, we show that the errors predicted by LTAU-FF can be used in practical applications for detecting out-of-domain data, tuning model performance, and predicting failure during simulations. We believe that LTAU will be a valuable tool for uncertainty quantification in atomistic force fields and is a promising method that should be further explored in other domains of machine learning.

97 MATHEMATICS AND COMPUTING↗

Prostate Intrafraction Motion Assessed by Simultaneous kV Fluoroscopy at MV Delivery II: Adaptive Strategies

Purpose: To investigate potential benefits of adaptive strategies for managing prostate intrafractional uncertainties when interfraction motion is corrected online. Methods and Materials: Prostate intrafraction motion was measured using kV fluoroscopy during MV delivery for 571 fractions from 30 hypofractionated radiotherapy patients. We evaluated trending over treatment course using analysis of variance statistics, and we evaluated the ability to correct patient-specific systematic error and apply patient-specific statistical margins after 2 to 15 fractions to compensate 90% of motion. We also evaluated the ability to classify patients into small- and large-motion subgroups based on the first 2 to 20 fractions using discriminant analysis. Results: No time trend was observed over treatment course, and intrafraction motion was patient specific (p < 0.0001). Systematic error in the first week correlated well with that in subsequent weeks, with correlation coefficients of 0.53, 0.50, and 0.41 in right-left (RL), anterior-posterior (AP), and superior-inferior (SI), respectively. After 5 fractions, the adaptive strategy resulted in average margin reductions of 0.3, 0.7, and 0.7 mm in RL, AP, and SI, respectively, with margins ranging from 1 to 3.2 mm in RL, 2 to 7.0 mm in AP, and 2 to 6.6 mm in SI. By contrast, population margins to include the same percentage of motion were 1.7, 4.0, and 4.1 mm. After 2 and 5 fractions, patients were classified into small- and large-motion groups with {approx}77% and {approx}83% accuracy. Conclusions: Adaptive strategies are feasible and beneficial for intrafraction motion management in prostate cancer online image guidance. Patients may be classified into large- and small-motion groups in early fractions using discriminant analysis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Compact And Robust Laser Impulse Measurement Device, With Ultrashort Pulse Laser Ablation Results

An impulse measurement device and analysis package was conceived, designed, constructed, tested, and demonstrated to be capable of: measuring nanoNewton-seconds to milliNewton-seconds of impulse due to laser-ablation; being transported as carry-on baggage; set-up and tear-down times of less than an hour; target exchange times of less than two minutes (targets can be ablated at multiple positions for thousands of shots); measurements in air and in vacuum; error of just a few percent; repeatability over a wide range of potential systematic error sources; and time between measurements, including ring-down and analysis, of less than 30 seconds. The instrument consists of a cantilever (i.e. leaf spring), whose time-dependent displacement/oscillation is measured and analyzed to determine the impulse imparted by a laser pulse to a target. These shapes are readily/commercially available, and any target material can be used, provided it can be fashioned in the form of a cantilever, or as a coating/film/tape, suitable for mounting on a cantilever of known geometry. The instrument was calibrated both statically and dynamically, and measurements were performed on brass, steel, and Aluminum, using laser pulses of {approx}7 ns, {approx}500 ps, and {approx}500 fs. The results agree well with those published in the literature, with surface effects, atmosphere, and pre-/post-pulses demonstrating interesting effects and indicating areas for further study. These parameters should be carefully controlled and held constant during a series of measurements. The impulse imparted by ablation due to laser filaments in air was also explored.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Systematic Approach for Evaluation of Capture Zones at Pump and Treat Systems Part 1

A Systematic Approach for Evaluation of Capture Zones at Pump and Treat Systems presents a systematic approach for the evaluation of capture zones at pump and treat systems, and provides an overview of a recently published USEPA document on the topic (EPA 600/R-08/003, January 2008). The target audience for the course is project managers who review those analyses and/or make decisions based on these types of analyses. This course will highlight:The importance of capture zone analysis during ground water remediation, particularly for sites requiring containmentKey concepts of capture, such as "target capture zones" and "converging lines of evidence"Typical errors made in capture zone analysisIn addition, steps associated with a systematic approach for capture zone analysis will be discussed. These steps include the following:Step 1: Review site data, site conceptual model, and remedy objectivesStep 2: Define site-specific Target Capture Zone(s)Step 3: Interpret water levelsPotentiometric surface maps (horizontal) and water level difference maps (vertical)Water level pairs (gradient control points)Step 4: Perform calculations (as appropriate based on site complexity)Estimated flow rate calculationCapture zone width calculationModeling (analytical and/or numerical) to simulate water levels, in conjunction with particle tracking and/or transport modelingStep 5: Evaluate concentration trends Step 6: Interpret actual capture based on steps 1-5, compare to Target Capture Zone(s), and assess uncertainties and data gaps Examples will be used to demonstrate key aspects of capture zone analysis.

Source record↗

Spatio-temporal distribution of Oklahoma earthquakes: Exploring relationships using a nearest-neighbor approach: Nearest-neighbor analysis of Oklahoma

Determining the spatiotemporal characteristics of natural and induced seismic events holds the opportunity to gain new insights into why these events occur. Linking the seismicity characteristics with other geologic, geographic, natural, or anthropogenic factors could help to identify the causes and suggest mitigation strategies that reduce the risk associated with such events. The nearest-neighbor approach utilized in this work represents a practical first step toward identifying statistically correlated clusters of recorded earthquake events. Detailed study of the Oklahoma earthquake catalog’s inherent errors, empirical model parameters, and model assumptions is presented. We found that the cluster analysis results are stable with respect to empirical parameters (e.g., fractal dimension) but were sensitive to epicenter location errors and seismicity rates. Most critically, we show that the patterns in the distribution of earthquake clusters in Oklahoma are primarily defined by spatial relationships between events. This observation is a stark contrast to California (also known for induced seismicity) where a comparable cluster distribution is defined by both spatial and temporal interactions between events. These results highlight the difficulty in understanding the mechanisms and behavior of induced seismicity but provide insights for future work.

58 GEOSCIENCES↗

TU-C-BRE-05: Clinical Implications of AAA Commissioning Errors and Ability of Common Commissioning ' Credentialing Procedures to Detect Them

Purpose: To test the ability of the TG-119 commissioning process and RPC credentialing to detect errors in the commissioning process for a commercial Treatment Planning System (TPS). Methods: We introduced commissioning errors into the commissioning process for the Anisotropic Analytical Algorithm (AAA) within the Eclipse TPS. We included errors in Dosimetric Leaf Gap (DLG), electron contamination, flattening filter material, and beam profile measurement with an inappropriately large farmer chamber (simulated using sliding window smoothing of profiles). We then evaluated the clinical impact of these errors on clinical intensity modulated radiation therapy (IMRT) plans (head and neck, low and intermediate risk prostate, mesothelioma, and scalp) by looking at PTV D99, and mean and max OAR dose. Finally, for errors with substantial clinical impact we determined sensitivity of the RPC IMRT film analysis at the midpoint between PTV and OAR using a 4mm distance to agreement metric, and of a 7% TLD dose comparison. We also determined sensitivity of the 3 dose planes of the TG-119 C-shape IMRT phantom using gamma criteria of 3% 3mm. Results: The largest clinical impact came from large changes in the DLG with a change of 1mm resulting in up to a 5% change in the primary PTV D99. This resulted in a discrepancy in the RPC TLDs in the PTVs and OARs of 7.1% and 13.6% respectively, which would have resulted in detection. While use of incorrect flattening filter caused only subtle errors (<1%) in clinical plans, the effect was most pronounced for the RPC TLDs in the OARs (>6%). Conclusion: The AAA commissioning process within the Eclipse TPS is surprisingly robust to user error. When errors do occur, the RPC and TG-119 commissioning credentialing criteria are effective at detecting them; however OAR TLDs are the most sensitive despite the RPC currently excluding them from analysis.

60 APPLIED LIFE SCIENCES↗

Back to Basics: First Principles of HRA

Human Reliability Analysis (HRA) continues to suffer from a myriad of technical gaps in its foundations. Core issues have been widely discussed but remain largely unaddressed, although the path taken to this point was paved with good intentions. Now, while this characterization may seem dramatic it is not intended to throw doubt onto HRA as a discipline or to diminish the value it has on increasing safety and resilience in nuclear power. Rather, it is intended to communicate that HRA has some serious challenges and is desperately in need of a critical evaluation. To quote Dougherty [1], “the misrepresentations that will undoubtedly arise may serve to provoke the necessary creativity.” What bears noting is that in the last thirty years since Alan Swain declared that “no adequate HRA had ever been done,” there has been little effort to correct the issues he highlighted. Human factors practice is still poorly implemented, many complex systems are fundamentally incompatible with reliable human performance, and there remains poor foundational support for many of the assumptions within HRA. We propose three categories of issues in HRA, philosophical, theoretical, and empirical and potential solutions to these issues.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Simulating Z 2 lattice gauge theory on a quantum computer

The utility of quantum computers for simulating lattice gauge theories is currently limited by the noisiness of the physical hardware. Various quantum error mitigation strategies exist to reduce the statistical and systematic uncertainties in quantum simulations via improved algorithms and analysis strategies. We perform quantum simulations of Z 2 gauge theory with matter to study the efficacy and interplay of different error mitigation methods: readout error mitigation, randomized compiling, rescaling, and dynamical decoupling. We compute Minkowski correlation functions in this confining gauge theory and extract the mass of the lightest spin-1 state from fits to their time dependence. Quantum error mitigation extends the range of times over which our correlation function calculations are accurate by a factor of 6 and is therefore essential for obtaining reliable masses.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Using artificial intelligence to detect human errors in nuclear power plants: A case in operation and maintenance

Human error (HE) is an important concern in safety-critical systems such as nuclear power plants (NPPs). HE has played a role in many accidents and outage incidents in NPPs. Despite the increased automation in NPPs, HE remains unavoidable. Hence, the need for HE detection is as important as HE prevention efforts. In NPPs, HE is rather rare. Hence, anomaly detection, a widely used machine learning technique for detecting rare anomalous instances, can be repurposed to detect potential HE. In this study, we develop an unsupervised anomaly detection technique based on generative adversarial networks (GANs) to detect anomalies in manually collected surveillance data in NPPs. More specifically, our GAN is trained to detect mismatches between automatically recorded sensor data and manually collected surveillance data, and hence, identify anomalous instances that can be attributed to HE. We test our GAN on both a real-world dataset and an external dataset obtained from a testbed, and we benchmark our results against state-of-the-art unsupervised anomaly detection algorithms, including one-class support vector machine and isolation forest. Our results show that the proposed GAN provides improved anomaly detection performance. Our study is promising for the future development of artificial intelligence based HE detection systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗