Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Envelope”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

Effective properties of semitransparent radiative cooling materials with spectrally variable properties

Radiative cooling is a promising solid-state, non-vapor-compression technology for passive refrigeration and air conditioning. Although this phenomenon occurs naturally, achieving a significant amount of cooling to make it a technically and economically viable technology requires highly engineered, spectrally selective radiative surfaces. These characteristics make radiative cooling difficult to estimate, particularly when it is integrated with other systems such as photovoltaic panels or building envelopes. The complexity further increases when the substrate also participates in the radiative cooling (along with the radiative coating). Energy estimation is becoming increasingly critical because of the recent focus on the semitransparent radiative coatings that transmit a variety of colors to enhance the aesthetic appeal of the system. In this work, we propose an iterative method to calculate the effective radiative properties, which provides the same net radiative cooling that would be observed using the spectral properties at both the coating and substrate surfaces. Compared to traditional methods that rely on either computationally expensive full spectral analysis or methods for averaging each radiative surface parameter locally, our proposed method focuses on calculating effective properties that provide the same the net cooling effect as a full spectral analysis by accounting the emissivity, absorptivity, and transmissivity collectively, thereby providing an overall estimation error of less than 0.2%. We believe that this study will be beneficial to the engineering communities that employ complex simulation codes and require lumped solar and thermal radiation related parameters.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Multi-scale and multi-physics analysis, design optimization, and experimental validation of heat exchangers utilizing high performance, non-round tubes

Air-to-refrigerant heat exchangers (HXs) are fundamental components in HVAC&R systems, and considerable research has been dedicated designing continually smaller, lighter, and more efficient HX designs. In recent years, researchers have leveraged advancements in Computational Fluid Dynamics (CFD), Finite Element Analysis (FEA), and optimization algorithms to consider primary tube shape and topology optimization to design highly compact, high performance HXs for a multitude of applications. In this research, we present a computationally efficient, comprehensive, multi-scale, and multi-physics analysis and optimization method for air-to-refrigerant HXs featuring automated CFD and FEA simulations and approximation-assisted optimization. This methodology was utilized to design HXs with shape-optimized, non-round tubes which outperform current state-of-the-art tube-fin HXs without compromising structural integrity. The optimal HXs were shown to deliver similar thermal performance to the baseline HXs while also achieving more than 20% reductions in airside pressure drop and core envelope volume and more than 30% reduction in internal volume. Comprehensive experimental validation of the optimization methodology was conducted through the testing of two prototypes in a standardized wind tunnel facility under multiple operating conditions. For prototype #1 under dry evaporator conditions, the predicted heat load agreed within ± 10% of measured values and the predicted airside pressure drop agreed within ± 30%, while for dehumidifying conditions, the predicted sensible and latent heat loads agreed within ± 10% and ± 20% of the measured values, respectively. For prototype #2, the predicted condenser heat load agreed within ± 3.0% of measured values, and the predicted airside pressure drop agreed within ± 27%. The acceptable agreement between simulation and experimental results for the present application highlights the flexibility of the novel optimization methodology to design next generation HXs with improved performance and reduced volume, weight, and environmental impact.

42 ENGINEERING↗

Unraveling spectral shapes of adventitious carbon on gold using a time-resolved high-resolution X-ray photoelectron spectroscopy and principal component analysis

To extract chemical information reliably, we propose a new data processing method based both on the creation of information vectors and on a vector base change. The originality of this method is the combination of the different core XPS peaks, Auger and/or valence bands in a single vector. We show that the measurement of a sample upon its progressive chemical change, such as accumulation of the adventitious carbon, allows us to create a new vector basis using linear algebra and Principal Component Analysis. In this work, we demonstrate the application of this method using adventitious carbon films on Au foil utilizing Au 4f, C 1s and O 1s spectral envelopes. This method expands the possibilities of XPS measured chemical environment analysis and is an operator-unbiased solution for materials for which the reference XPS spectra are not available. In this demonstration, the emphasis is placed on identifying changes in a C 1s peak assumed to be adventitious carbon and highlight uncertainties associated with calibrating the binding energy scale using a simple peak model to identify a component C 1s assumed to be saturated hydrocarbon in origin.

36 MATERIALS SCIENCE↗

Protecting building occupants against the inhalation of outdoor-origin aerosols

During normal operations, buildings can protect their occupants from outdoor airborne particle hazards of all types, including airborne pollutants. A long-term international research effort has advanced our knowledge of building protection physics. Recently we have developed an operationally efficient, regional-scale methodology - Regional Shelter Analysis - to account for both building protection effects and the typical distribution of people in and among buildings. To provide input to this capability, we estimate here the degree of protection afforded by the currently existing US building stock. Here, we first assemble and summarize the published literature relevant to indoor particle losses including (a) deposition to indoor surfaces, (b) losses that occur when particles penetrate through the building envelope, and (c) heating, ventilation and air conditioning (HVAC) system filtration efficiencies as well as general building operating conditions. Building protection against inhaling particulate hazards varies strongly, by orders of magnitude, according to particle size, airborne particle loss rate, and to a lesser extent building use (occupancy). Protection increases modestly as particle size increases from 0.1 to 1 μm and significantly as particle size increases from 1 to 10 μm. Model results are placed in context with previously reported measurements. Suggestions for future work, including enhanced validation datasets are provided.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Extending the Brick schema to represent metadata of occupants

Here, energy-related behaviors of occupants constitute a key factor influencing building performance; accordingly, the measured occupant data can support the objective assessment of the indoor environment and energy performance of buildings, which can inform building design and operational decisions. Existing data schemas focus on metadata of sensors, meters, physical equipment, and IoT devices in buildings; however, they are limited in representing the metadata of occupant data, including occupants' presence in spaces, movement between spaces, interactions with building systems or IoT devices, and preference of indoor environmental needs. To address this gap, an extension to the widely adopted metadata schema, Brick, is proposed to represent the contextual, behavioral, and demographic information of occupants. The proposed extension includes four parts: (1) a new “Occupant” class to represent occupants' demography and energy related behavioral patterns, (2) new subclasses under the Equipment class to represent envelope system and personal thermal comfort devices, (3) new subclasses under the Point class to represent occupant sensing and status, and (4) new auxiliary properties for occupant interactable equipment to represent the level of controllability for each piece of equipment by occupants. The extension is implemented in the Brick schema and has been tested using multiple occupant datasets from the ASHRAE Global Occupant Database. The extension enables Brick schema to capture diverse types of occupant sensing data and their metadata for FAIR data research and applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Lpp positions peptidoglycan at the AcrA-TolC interface in the AcrAB-TolC multidrug efflux pump

The multidrug efflux pumps of Gram-negative bacteria are a class of complexes that span the periplasm, coupling both the inner and outer membranes to expel toxic molecules. The best-characterized example of these tripartite pumps is the AcrAB-TolC complex of Escherichia coli. However, how the complex interacts with the peptidoglycan (PG) cell wall, which is anchored to the outer membrane (OM) by Braun’s lipoprotein (Lpp), is still largely unknown. In this work, we present molecular dynamics simulations of a complete, atomistic model of the AcrAB-TolC complex with the inner membrane, OM, and PG layers all present. We find that the PG localizes to the junction of AcrA and TolC, in agreement with recent cryo-tomography data. Free-energy calculations reveal that the positioning of PG is determined by the length and conformation of multiple Lpp copies anchoring it to the OM. The distance between the PG and OM measured in cryo-electron microscopy images of wild-type E. coli also agrees with the simulation-derived spacing. Finally, sequence analysis of AcrA suggests a conserved role for interactions with PG in the assembly and stabilization of efflux pumps, one that may extend to other trans-envelope complexes as well.

59 BASIC BIOLOGICAL SCIENCES↗

Italian prototype building models for urban scale building performance simulation

Urban building energy modeling (UBEM) seeks to evaluate strategies to optimize building energy use at urban scale to support a city's building energy goals. Prototype building models are usually developed to represent typical urban building characteristics of a specific use type, construction year, and climate zone, as detailed characteristics of individual buildings at urban scale are difficult to obtain. This study investigated the Italian building stock, developing 46 building prototypes, based on construction year, for residential and office buildings. The study included 16 single-family buildings, 16 multi-family buildings, and 14 office buildings. Building envelope properties and heating, ventilation, and air conditioning system characteristics were defined according to existing building energy codes and standards for climatic zone E, which covers about half the Italian municipalities. Novel contributions of this study include (1) detailed specifications of prototype building energy models for Italian residential and office buildings that can be adopted by UBEM tools, and (2) a dataset in GeoJSON format of Italian urban buildings compiled from diverse data sources and national standards. Finally, the developed prototype building specifications, the building dataset, and the workflow can be applied to create other building prototypes and to support Italian national building energy efficiency and environmental goals.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A simulation-based assessment of technologies to reduce heat emissions from buildings

Heat emissions from buildings are part of anthropogenic heat leading to urban overheating. This paper aims to assess how technologies (i.e., energy conservation measures - ECMs), used to decrease energy use, may also reduce heat emissions from buildings. This study employs the physics-based engine EnergyPlus to simulate the main components of heat emissions from buildings to ambient air: envelope, zone, and systems. Hourly simulations are run for IECC single- and multi-family reference models with three representative climates: Miami, Baltimore, and Chicago. The results show that the performance of ECMs varies among weather, seasons, and residential typologies. Particularly, some ECMs (i.e., cool coatings, heat pumps, additional insulation, energy-awareness occupants) show a strong decrease in heat emissions, yet they are not always correlated with proportional decreases in energy use. When all ECMs are combined, the reductions are larger on heat emissions (89%) than on site energy (65%) from the base cases. During summer in Miami, the combination of ECMs shows a decrease in heat emissions from the building surface component of 80% during daytime, 92% for the HVAC component and a counterbalanced increase in the zone component of 88%, bringing to a daily decrease in total heat emissions. The main contributions of this study are quantifying how typical ECMs influence residential building heat emissions using EnergyPlus simulations and informing urban planners and stakeholders on prioritizing measures for mitigating urban overheating problems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

National energy savings potential of cellular shades: A measurement and simulation study

Windows are major contributors to energy demand in residential homes because of their inferior thermal resistance compared with the opaque envelope, and sometimes from unwanted solar heat gain. Window attachments can help mitigate the energy demand by controlling the solar heat gains and enhancing window thermal resistance. Cellular shades have the potential of superior thermal performance compared with generic shades because of its honeycomb structure. Here, in this study, the team analyzed the energy savings potential of cellular shades in residential homes via experimental testing for two heating seasons and energy simulations. Five shading devices—three single-cell and two double cellular/cell-in-cell shades—were used to compare the performance with generic horizontal venetian blinds using two nearly identical side-by-side rooms in a residential home. The experimental testing showed daily heating energy savings in the range of 17%–36% compared with the case without shades. The experimental testing data also exhibited improvements in thermal comfort when using cellular shades. Additionally, energy simulations were performed to evaluate the energy savings potential of the cellular shades using a residential prototype home, which demonstrated energy savings up to 9 kWh/m2/year in cold climates. The total site energy savings for heating and cooling from cellular shades was up to ~9% for the home with a heat pump and up to ~15% for a home with a gas furnace compared with cases without any shading devices. The energy savings at a national scale were up to 14.6 TWh assuming a 20% penetration rate in residential homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Vapor–liquid equilibrium estimation of n-alkane/nitrogen mixtures using neural networks

Understanding fluid phase behavior, like VLE, in high P&T conditions is crucial for developing high-fidelity simulations of chemically reacting flows in liquid-fueled combustion systems and also forms an integral part of the design-modeling of the control processes in chemical industries. Two data-driven models have been proposed here in this study, each of which was competent in estimating VLE for the Type III binary systems of C 10 /N 2 and C 12 /N 2 , at pressures ranging up to 50–60 MPa. Both models showed better performance in predicting equilibrium pressure as compared to VLE modeled using PR-EOS. A modified model has also been proposed, capable of estimating the full phase envelope for the binary systems of C 10 /N 2 and C 12 /N 2 across a wide range of temperatures, and thus exhibit the mixture critical pressure at the concerned temperature. The diverse applicability of the proposed network architecture was further exhibited while estimating the VLE of a ternary system of C 1 /C 10 /N 2 .

97 MATHEMATICS AND COMPUTING↗

An adaptive sampling augmented Lagrangian method for stochastic optimization with deterministic constraints

The primary goal of this paper is to provide an efficient solution algorithm based on the augmented Lagrangian framework for optimization problems with a stochastic objective function and deterministic constraints. Our main contribution is combining the augmented Lagrangian framework with adaptive sampling, resulting in an efficient optimization methodology validated with practical examples. To achieve the presented efficiency, here we consider inexact solutions for the augmented Lagrangian subproblems, and through an adaptive sampling mechanism, we control the variance in the gradient estimates. Furthermore, we analyze the theoretical performance of the proposed scheme by showing equivalence to a gradient descent algorithm on a Moreau envelope function, and we prove sublinear convergence for convex objectives and linear convergence for strongly convex objectives with affine equality constraints. The worst-case sample complexity of the resulting algorithm, for an arbitrary choice of penalty parameter in the augmented Lagrangian function, is $\mathscr{O}$(ϵ -3-δ ) , where ϵ > 0 is the expected error of the solution and δ > 0 is a user-defined parameter. If the penalty parameter is chosen to be $\mathscr{O}$(ϵ -1 ), we demonstrate that the result can be improved to $\mathscr{O}$(ϵ -2 ) , which is competitive with the other methods employed in the literature. Moreover, if the objective function is strongly convex with affine equality constraints, we obtain $\mathscr{O}$(ϵ -1 log(1/ϵ)) complexity. Finally, we empirically verify the performance of our adaptive sampling augmented Lagrangian framework in machine learning optimization and engineering design problems, including topology optimization of a heat sink with environmental uncertainty.

97 MATHEMATICS AND COMPUTING↗

Materials property changes in ETU-10 graphite due to neutron irradiation at elevated temperatures

Graphite grade ETU-10, from IBIDEN Co., Ltd. Has been irradiated in the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory (ORNL). The irradiation program was developed to provide a preliminary study the irradiation-induced property changes to the dimensions/volume, elastic properties, strength, electrical resistivity, coefficient of thermal expansion, and thermal diffusivity/conductivity over a range of temperatures and neutron exposures that may be relevant for future nuclear reactors. The irradiation envelope covers a range of irradiation temperatures (300°C–900 °C) and fluences (up to 40 × 10 25 n/m 2 [E > 0.1 MeV] or ~30 dpa) that would be relevant for advanced nuclear reactors. Further, the dimensional change was observed to be anisotropic for an isotropic graphite, the specimen dimensions, volume, Young's modulus, shear modulus, and strength all displayed a parabolic fluence dependence, the electrical resistivity had a rapid rise followed by a decrease and a later increase, at high fluence the mean coefficient of thermal expansions was similar for all irradiation temperatures, and thermal conductivity rapidly decreased followed by a continued loss.

36 MATERIALS SCIENCE↗

A small-angle neutron scattering study of the physical mechanism that drives the action of a viral fusion peptide

Viruses have evolved a variety of ways for delivering their genetic cargo to a target cell. One mechanism relies on a short sequence from a protein of the virus that is referred to as a fusion peptide. In some cases, the isolated fusion peptide is also capable of causing membranes to fuse. Infection by HIV-1 involves the 23 amino acid N-terminal sequence of its gp41 envelope protein, which is capable of causing membranes to fuse by itself, but the mechanism by which it does so is not fully understood. In this study, a variant of the gp41 fusion peptide that does not strongly promote fusion was studied in the presence of vesicles composed of a mixture of unsaturated lipids and cholesterol by small-angle neutron scattering and circular dichroism spectroscopy to improve the understanding of the mechanism that drives vesicle fusion. The peptide concentration and cholesterol content govern both the peptide conformation and its impact on the bilayer structure. The results indicate that the mechanism that drives vesicle fusion by the peptide is a strong distortion of the bilayer structure by the peptide when it adopts the β-sheet conformation.

60 APPLIED LIFE SCIENCES↗

Computational micromechanics model based failure criteria for chopped carbon fiber sheet molding compound composites

Chopped carbon fiber sheet molding compound has a great potential in lightweight automotive, marine, and aerospace applications. One of the most challenging tasks is to predict the failure strength of the material due to its anisotropy and heterogeneity, as well as complex stress states in real-world working conditions. In this work, a novel constitutive model of carbon fiber chip is proposed to capture the pre- and post-failure behaviors under different loading modes. On this basis, we propose a new computational micromechanics model, which is calibrated and validated by uniaxial tensile, compressive, and in-plane shear experiments. Furthermore, a set of microstructures representative volume element (RVE) models under complex loading conditions are reconstructed to understand the relationship between the microstructure characteristics and the failure envelopes. Finally, several modified versions of classical failure criteria are proposed for anisotropic materials with consideration of the fiber orientation tensor. The modified Tsai-Wu failure criterion, which shows the best accuracy among all failure criteria, is highlighted in the comparative study.

36 MATERIALS SCIENCE↗

An integrated computational materials engineering framework to analyze the failure behaviors of carbon fiber reinforced polymer composites for lightweight vehicle applications

A bottom-up multi-scale modeling approach is used to develop an Integrated Computational Materials Engineering (ICME) framework for carbon fiber reinforced polymer (CFRP) composites, which has the potential to reduce development to deployment lead time for structural applications in lightweight vehicles. In this work, we develop and integrate computational models comprising of four size scales to fully describe and characterize three types of CFRP composites. In detail, the properties of the interphase region are determined by an analytical gradient model and molecular dynamics analysis at the nano-scale, which is then incorporated into micro-scale unidirectional (UD) representative volume element (RVE) models to characterize the failure strengths and envelopes of UD CFRP composites. Then, the results are leveraged to propose an elasto-plastic-damage constitutive law for UD composites to study the fiber tows of woven composites as well as the chips of sheet molding compound (SMC) composites. Subsequently, the failure mechanisms and failure strengths of woven and SMC composites are predicted by the meso-scale RVE models. Finally, building upon the models and results from lower scales, we show that a homogenized macro-scale model can capture the mechanical performance of a hat-section-shaped part under four-point bending. Along with the model integration, we will also demonstrate that the computational results are in good agreement with experiments conducted at different scales. The present work illustrates the potential and significance of integrated multi-scale computational modeling tools that can virtually evaluate the performance of CFRP composites and provide design guidance for CFRP composites used in structural applications.

36 MATERIALS SCIENCE↗

Verification and benchmarking relativistic electron beam transport through a background gas

It is necessary to establish confidence in high-consequence codes containing an extensive suite of physics algorithms in the regimes of interest. Verification problems allow code developers to assess numerical accuracy and increase confidence that specific sets of model physics were implemented correctly in the code. The two main verification techniques are code verification and solution verification. In this work, we present verification problems that can be used in other codes to increase confidence in simulations of relativistic beam transport. Specifically, we use the general plasma code EMPIRE to model and compare with the analytical solution to the evolution of the outer radial envelope of a relativistic charged particle beam. Additionally, we also outline a benchmark test of a relativistic beam propagating through a vacuum and pressurized gas cell, and present the results between EMPIRE and the hybrid code GAZEL. Further, we discuss the subtle errors that were caught with these problems and detail lessons learned.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A bilevel multistage stochastic self-scheduling model with indivisibilities for trading in the continuous intraday electricity market

In this paper, we study the profit maximization problem of a virtual power plant trading in the continuous intraday electricity market. Our virtual power plant model is compatible with renewable, and thermal assets, covering a range of virtual power plants currently participating in energy markets. We model the trading problem as a bilevel multistage stochastic program. The upper level of the problem accounts for the profit maximization of the virtual power plant with explicit modeling of the technical constraints of the operational status of the thermal power plant including minimum start-up and shut-down times, ramp-up and ramp-down rates, and minimum generation level. The upper level also decides which continuous and indivisible (fill-or-kill) orders are submitted to the market. The lower-level problem accounts for the clearing of the continuous intraday market, i.e., matching of buy and sell orders. Because of the presence of fill-or-kill orders, the lower-level problem is mixed-integer, which prevents its direct conversion to a single-level problem using duality. In order to solve this challenging problem, we develop a convex-hull extended formulation for the lower-level problem, apply duality theory to obtain a single-level stochastic equivalent formulation, and employ McCormick envelopes to turn the problem into a multistage stochastic mixed-integer linear problem, which we solve using the stochastic dual dynamic integer programming algorithm. We conduct numerical experiments and analyze the optimal trading behavior of a virtual power plant trading in an ideal continuous market without arbitrage.

Bilevel multistage stochastic programming problem↗

Prototype energy models for data centers

Data centers in the United States consume about two percent of the nation’s electricity. Because heat gains from IT equipment drive cooling demand, data centers offer unique opportunities for energy savings. However, no prototype energy model for data centers is available in the suite of existing U.S. Department of Energy’s Commercial Prototype Building Models. Here we present the development of two new data center prototype models and their implementation in OpenStudio and EnergyPlus. The small-size data center model represents a computer room in a building served by computer room air conditioners (CRACs); while the large-sized model represents stand-alone data centers served by computer room air handlers (CRAHs) with a central chiller plant. For each data center model, two levels of IT equipment (ITE) load density were considered, to cover the wide range of IT power density of data centers: 40 and 100 W/ft 2 (430 and 1076 W/m 2 ) for the computer room, and 100 and 500 W/ft 2 (1076 and 5382 W/m 2 ) for the stand-alone data center. All other assumptions, such as building envelope, lighting, HVAC efficiencies and schedules, were based on the minimal requirements of ASHRAE Standard 90.1 at various vintages. We introduced a novel concept of supply and return air approach temperatures to capture the essential effects of non-uniform airflow and temperature distribution in data centers. The approach temperatures were pre-computed by computational fluid dynamics (CFD) simulations for various configurations of ITE loads and airflow containment management in data centers. A new feature was developed in EnergyPlus to implement the approach temperature method. A case study was conducted to demonstrate the use of the data center models. The two data center models cover all U.S. climate zones and can be used to evaluate energy saving measures for data centers, as well as to support development of data center energy efficiency codes and standards.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗