Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Efficient”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

An Efficient Holographic Huygens? Metasurface based on Dielectric Resonant Meta-Atoms.

Subwavelength-thin metasurfaces have shown great promises for the control of optical wavefronts, thus opening new pathways for the development of efficient flat optics. In particular, Huygens’ metasurfaces based on all-dielectric resonant meta-atoms have already shown a huge potential for practical applications with their polarization insensitivity and high transmittance efficiency. Here, we experimentally demonstrate a holographic Huygens’ metasurface based on dielectric resonant meta-atoms capable of complex wavefront control at telecom wavelengths. Our metasurface produces a hologram image in the far-field with 82% transmittance efficiency and 40% imaging efficiency. Such efficient complex wavefront control shows that Huygens’ metasurfaces based on resonant dielectric meta-atoms are a big step towards practical applications of metasurfaces in wavefront design related technologies, including computer-generated holograms, ultra-thin optics, security and data storage devices.

47 OTHER INSTRUMENTATION↗

On the Efficiency $\eta$ and the Homogeneity of TiN Kinetic Inductance Detectors Produced through Atomic Layer Deposition

Microwave Kinetic Inductance Detectors (MKIDs) belong to non-equilibrium superconducting devices. It is a new promising device due to high quantum efficiency, low theoretical noise limit, multiplex frequency domain, photon-number-resolving, and energy resolving. In the case of MKIDs, a change in the kinetic inductance is produced by the breaking of Cooper pairs, modifying the electrodynamic response of the superconductor. The production process of an MKID consists of depositing a superconducting thin film on an insulating substrate and applying standard lithographic patterning techniques to produce a resonator structure. When an MKID is produced via sputtering, film nonuniformity is observed, producing instability, low yield, frequency collisions, and low energy resolution. We exploring film uniformity in films produced with Atomic Layer Deposition (ALD) and through ALD archive high values in the energy resolution. The uniformity of ALD is evaluated via measurement of the critical temperature of 4 MKIDs. Two MKIDs belong to the first fabrication process and the other two to another. The results obtained are: ΔTc/max(σT1,σT2) is 0.45 for A1-B1 and 0.21 for A2-B2. The difference in the Tc for MKIDs of the same wafer is around 5.1 mK and from different wafers, the maximum difference is 66 mk with a minimum of 48 mK. However, with the high uniformity archived, we obtained a poor response of the MKIDs when a photon is absorbed. As a consequence of the low response, we examined in the literature about the process of photon absorption. In this evaluation, we were focusing on the down-conversion efficiency as a possible cause for the degraded energy resolution. In this process, one part of the initial energy of the photon is lost, transferred to the creation of quasiparticles and phonons. The phonons that do not possess enough energy to break a Cooper pair are lost from the system. This loss in energy is accounted for by the eff iciency η which has a constant value reported as 0.57 (! from simulation). Due to the efficiency had been reported always as constant. We proceed to evaluate its value through a new method. The process consists of measuring the gain of the system via the photon transfer curve and thermal calibration. The efficiency obtained with this new method is of 0.008 which has a lower value in comparison with the simulation. The methods to obtain the critical temperature, as well as the new method to evaluate the efficiency of an MKID will be shown in this work.

43 PARTICLE ACCELERATORS↗

High-Efficiency Tandem Absorbers for Economical Solar Hydrogen Production

The objective of this project is to develop a semiconductor-based device capable of over 20% solar-to-hydrogen efficiency with several thousand hours of stability under operating conditions. The ultimate system design will incorporate electrode components that can be fabricated cost-effectively and do not present a barrier to scale-up. Solar-to-hydrogen efficiency will be improved from our world-record holding 12.4% to over 20% by developing novel tandem semiconductor materials and configurations. Our approach focuses on classes of materials that have either demonstrated exceptionally high efficiency or theoretically can produce highly efficient materials. The four tandem-material approaches we will take are: III-Vs on GaAs, InGaN on Si, III-V-N on Si, and dual photoelectrode pairings. Durability will be enhanced from a few hundred hours to nearly 1000 hours, with a stretch target of 3500 hours, through catalytic nitride, oxide, and sulfide-based semiconductor surface modifications. Economical hydrogen production is attainable using high-efficiency III-V photoelectrochemical materials with cost reductions from emerging epitaxial synthesis technologies such as spalling, epitaxial lift-off, or close-space vapor transport. We will address synthesis cost, in a limited capacity, by investigating novel material configurations. The expected outcome is a prototype photoreactor that produces 3 L of standard hydrogen within an 8-hour period under moderate solar concentration (10x), which can be accomplished using only 6 cm2 of a 20% STH material. Inputting attainable performance metrics from our approach into the H2A Central Production Model 3.0 shows a clear pathway to hydrogen production cost of <$2/gge.

14 SOLAR ENERGY↗

Applying Value at Risk Analysis towards Energy Efficiency Investments

Value at Risk (VaR) is a measure of risk for potential losses within a portfolio of investments. Investments in energy efficiency in a manufacturing environment compete in terms of payback period, ease of investment, and transaction costs with other investments (production, safety, engineering, etc.). Because manufacturers have limited amounts of capital to allocate, investments in productivity tend to be prioritized over energy efficiency projects that offer similar paybacks. Value at Risk (VaR) can be used to quantify how risk-weighted expenditures change over time. Energy efficiency investments are often believed to offer relatively stable payoffs compared to changes in production and other assets, particularly when evaluated using methodologies such as simple payback. Incorporating methodologies such as VaR can provide a stronger business case for energy efficiency investments by quantifying value beyond what is captured in other Return on Investment calculations.In this paper we outline a methodology for applying VaR in the context of the variety of investments made by manufacturing organizations. Additionally, we profile the stability of energy efficiency (EE) and renewable energy (RE) investments compared to other types of investments made in manufacturing. By applying VaR to these investments, energy managers can better translate the financial benefits of energy-related capital projects in a way that is more compelling to Corporate Finance and Treasury departments. This common language also allows Corporate Finance and Treasury departments to support large, strategic deployments of capital for such projects based on a targeted objective – the management of financial risk for the organization’s shareholders.

Levine, Eli↗

"COMBUSTION DEVELOPMENT OF A HIGH EFFICIENCY DIESEL MICRO PILOT NATURAL GAS ENGINE."

Dual fuel engine operation with premixed natural gas as the main fuel and diesel pilot ignition has been gaining interest among research and industry as natural gas is among the most promising existing alternative fuels. The dual fuel engine performance has been shown to equal and sometimes, depending on operating conditions, better the performance and efficiency of the diesel engine. Along with its advantages on the combustion high efficiency, diesel-like performance, and emissions of NOx and particulate matter reduction, some disadvantages are brought by the application of such operation. At light load conditions, there is an increase in CO and HC emissions, low fuel efficiency and combustion stability. While operating at higher loads, the dual fuel engine performance showed to be limited by combustion knock. This effectively reduces the maximum break mean effective pressure (BMEP) the engine can output when compared to a diesel engine. Although combustion knock is well defined in SI and diesel engines, dual fuel knock characterization still needs more investigation. This project centers on developing a fuel system for a diesel engine conversion to dual fuel to deliver high load and high efficiency. The selected engine has been converted to the dual fuel operation and dual fuel combustion has been demonstrated. After achieving the project goal of a high load and high efficiency dual fuel engine, the combustion knock in dual fuel operation will be characterized and a method for detection and intensity calculation will be modeled. The characterization will also be compared to spark ignition (SI) and reactivity-controlled compression ignition (RCCI) operating engines.

03 NATURAL GAS↗

Putting Data to Work: Using Building Energy Performance Data to Expand the Market for Energy Efficiency in Buildings

An increasing number of state and local jurisdictions are implementing building performance reporting laws, which generate large quantities of useful data on the characteristics and resource consumption of the building stock. Yet, to realize the potential of these policies, the data must not only be disclosed, but put to work to drive energy savings. Under a three-year pilot, Washington DC (DC), New York City (NYC) and their partners are pioneering the use of data from building performance reporting in energy efficiency programs. To minimize the administrative burden of managing, combining, and sharing these data sets, the cities are utilizing the U.S. Department of Energy’s (DOE) open-source Standard Energy Efficiency Data (SEED) Platform. The Putting Data to Work project team is working with efficiency program administrators to develop and implement new and innovative ways in which the data collected through benchmarking, energy audits, and related policies can be used to improve energy policies and planning, unlock data directly for market use, scale-up the market for energy efficiency services, drive competition, better target utility incentive programs, and inform measurement and verification. This paper details achievements and key findings in DC and NYC to date, including the importance of high compliance, data quality, and data cleansing in using the information collected; methods that the cities are using to apply data to drive maximum energy efficiency; and the importance of inter- and intra-agency collaboration in program success. We also outline the path forward and detail expected outcomes and scalability of project activities.

Beddingfield, Erin↗

Modifications to the runner blade to Improve Off - Design Efficiencies of Hydraulic Turbines

Hydroturbines are known to have very high efficiency at their best efficiency point (BEP). However, it has become increasing beneficial to run some hydroturbines at conditions that are significantly different than BEP. This is a direct result of volatile price fluctuations on the electric market, limited storage capabilities, and environmental rules and regulations. Running the hydroturbine at off-design conditions can result in a significant amount of residual swirl in the draft tube. The presence of this residual swirl is particularly detrimental to the performance of Francis hydroturbines since they rely on a pressure head to generate power. Previous research at The Pennsylvania State University numerically discovered that injecting water through the trailing edge of the wicket gates could change the bulk flow direction upstream of the runner blades. In this manner, the flow rate and swirl angle entering the runner blade could be altered to limit residual swirl in the draft tube. The research determined that properly tuned jets could result in a significant improvement in turbine efficiency when the hydroturbine was operating at low flow. However, this required pumping water through channels into a region of relatively high pressure. This pump requirement lessened the effectiveness of the wicket gate trailing edge injection. The concept of water jet injection was further explored in the present work. However, instead of injecting water into a region of relatively high pressure, water jets were placed at the trailing edge of the runner blades where there is a region of relatively low pressure. It was determined that, although this water jet injection improved the off-design efficiency of a low flow case by 0.8%, the hydroturbine now required a larger head in order to maintain the flow rate. The present work found no increase in efficiency for the high flow case with the added water jet injection technique.

13 HYDRO ENERGY↗

Making Grid-interactive Efficient Buildings a “Win” for Both Customers and Utilities

Buildings account for more than 70% of U.S. electricity use and at least one-third of U.S. economy-wide CO2 emissions. Changing the timing and overall amount of electricity consumption in buildings would significantly reduce energy costs to consumers and facilitate the transition to a decarbonized economy. Grid-interactive efficient buildings (GEBs) incorporate energy efficiency, smart technologies, and active use of distributed energy resources (DERs) to provide these benefits. As the link between the customer and the power system, utilities are central to widespread deployment of GEBs. Yet, despite the significant cost savings and operational benefits of GEBs for utilities, deployment has remained limited. This paper explores emerging models for enabling utilities to facilitate GEB adoption. Building off foundational research conducted to develop the U.S. DOE’s A National Roadmap for Grid-Interactive Efficient Buildings, we describe the most novel recent examples of ways in which utilities and regulators have made demand-side innovation a win for both the customer and the utility. Emerging concepts include: (1) performance incentive mechanisms to align GEB deployment with utility financial motivations, (2) the use of subscription pricing (i.e., fixed monthly bills) to promote load flexibility and energy efficiency, (3) rate-basing utility-controlled behind-the-meter assets, and (4) coupling energy efficiency and load flexibility with electrification proposals to ensure that customer benefits are maximized. The paper concludes with a discussion about prospects for widespread GEB deployment and utilization by utilities, and how to scale efforts.

Satchwell, Andrew↗

Highly efficient small molecule multi-junction organic photovoltaic cells

A highly efficient multi junction photovoltaic device, such as a two, three, or four junction device, is disclosed. The multi-junction device may include a first subcell comprising a first photoactive region and a second subcell comprising a second photoactive region. The first and second photoactive regions are designed to minimize spectral overlap and maximize photocurrent across a broad absorption spectra, such as wavelengths ranging from 400 nm to 900 nm. The device may further include an inter-connecting layer, disposed between the first subcell and the second subcell, that is at least substantially transparent. By introducing a transparent interconnecting layer, a dual element (tandem) cell achieves a power conversion efficiency of 10.0±0.5%. By adding an additional (3rd) sub-cell that absorbs at the second order optical interference maximum within the stack. The triple junction cell significantly improves the quantum efficiency at shorter wavelengths, achieving a power conversion efficiency of 11.1±0.5%. Adding additional sub-cells has been shown to increase power conversion efficiency above 12%.

Che, Xiaozhou↗

Record Efficiency InGaAs Thermophotovoltaic Cells For Energy Storage Applications

Utility-scale energy storage is a significant technical challenge and a key barrier to widespread adoption of renewable energy. An efficient, modular, and scalable solution can be achieved by storing energy in the form of high-temperature heat and then extracting energy, on demand, using thermophotovoltaic (TPV) cells to convert the heat back to electricity. The ideal thermal emitter temperature is determined by balancing the desire for higher power densities, high-temperature compliant materials, and efficient, cost-effective thermophotovoltaic cells, among other considerations. 0.74-eV InGaAs lattice-matched to InP is a good choice for a cell absorber, and here we describe our development of InGaAs TPV cells with efficiencies of 38.8% from an ~1850 degrees celsius source temperature. This is the highest efficiency yet measured and reported for a single-junction TPV device. This efficiency was achieved by carefully quantifying and then reducing the parasitic absorption in the semiconductor layers, and by significantly reducing the series resistance to minimize the power loss.

ENERGY STORAGE,ENGINEERING,SOLAR ENERGY↗

Impact of Nozzle Condition on Powder Catchment Efficiency for Coaxial Powder Direct Energy Deposition

Blown powder directed energy deposition is well-designed for fine resolution additive manufacturing processing. Coaxial powder deposition heads use an outer layer of shielding gas directed by an outer nozzle to prevent oxidation occurring during the powder melting process. Powder blown feedstock catchment efficiency can be as low as 50-80% whereas wire deposition systems are closer to 98% efficient. The present study evaluates the impact of directed energy deposition nozzle condition on catchment efficiency. Changes in the overall outer shielding gas nozzle length has been found to increase material usage efficiency by 10% through convergence of the powder flow. The results of this experiment show that for coaxial powder deposition head design, if the standoff distance can safely be decreased, powder catchment efficiency can be increased as the outer shielding gas nozzle is increased in length, or the standoff distance is decreased.

Heinrich, Lauren↗

Impact of Nozzle Condition on Powder Catchment Efficiency for Coaxial Powder Direct Energy Deposition

Blown powder directed energy deposition is well-designed for fine resolution additive manufacturing processing. Coaxial powder deposition heads use an outer layer of shielding gas directed by an outer nozzle to prevent oxidation occurring during the powder melting process. Powder blown feedstock catchment efficiency can be as low as 50-80% whereas wire deposition systems are closer to 98% efficient. The present study evaluates the impact of directed energy deposition nozzle condition on catchment efficiency. Changes in the overall outer shielding gas nozzle length has been found to increase material usage efficiency by 10% through convergence of the powder flow. The results of this experiment show that for coaxial powder deposition head design, if the standoff distance can safely be decreased, powder catchment efficiency can be increased as the outer shielding gas nozzle is increased in length, or the standoff distance is decreased.

Heinrich, Lauren↗

Maximizing Operational Efficiencies in Waste Management on the Hanford Plateau Remediation Contract in a Down-turned Market - 13484

Recent changes in DOE priorities and funding have pressed DOE and its contractors to look for innovative methods to sustain critical operations at sites across the Complex. At the Hanford Site, DOE Richland Operations and its prime contractor, CH2M Hill Plateau Remediation Company (CHPRC), have completed in-depth assessments of the Plateau Remediation Contract (PRC) operations that compared available funding to mission and operational objectives in an effort to maintain requisite safety and compliance margins while realizing cost savings that meet funding profiles. These assessments included confirmation of current baseline activities, identification of potential efficiencies, barriers to implementation, and potential increased risks associated with implementation. Six operating PRC waste management facilities were evaluated against three possible end-states: complete facility closure, maintaining base operations, and performing minimum safe surveillance and maintenance activities. The costs to completely close evaluated facilities were determined to be prohibitively high and this end-state was quickly dropped from consideration. A summary of the analysis of remaining options by facility, efficiencies identified, impact to risk profiles, and expected cost savings is provided in Table I. The expected cost savings are a result of: - right-sizing and cross-training work crews to address maintenance activities across facilities; - combining and sequencing 'like-moded' operational processes; - cross-cutting emergency planning and preparedness staffing; - resource redistribution and optimization; - reducing areas requiring routine surveillance and inspection. For the efficiencies identified, there are corresponding increases in risk, including a loss of breadth and depth of available resources; lengthened response time to emergent issues; inability to invest in opportunities for improvement (OFIs); potential single-point failures or non-compliancies due to resource scarcity; limited cross-training capability; and reduced capability to respond to changes in DOE priorities. Finally, there are many challenges to achieving these cost savings. With a workforce nearing retirement effective succession planning becomes critical to success and requires establishing a balance between the cost of hiring and training and cost-saving activities. With six active waste management facilities spread across nearly 15 square miles, scheduling and deploying cross-trained surveillance and maintenance teams is a logistical challenge, particularly as the loss of funding has not diminished emphasis by regulatory agencies placed on the safe and compliant performance of DOE and its contractors. As reflected in Table I, efficiencies are currently being implemented on the Hanford Plateau Remediation Contract (PRC) that deliver cost savings that align with the current site budget while maintaining critical capabilities. It is currently estimated that these efficiencies will result in a cost savings of approximately $9 million for FY13 in base and minimum safe operations on the PRC - a cost reduction of more than 13 percent over FY12 and nearly 30 percent over FY09 levels. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Efforts to Improve Efficiency of Extraction Well Operation at the Fernald Preserve, Harrison, Ohio - 16177

The Fernald Preserve, a former uranium processing facility that produced high-purity uranium metal products during the Cold War, is located in southwest Ohio. The facility became a US Department of Energy Office of Legacy Management (LM) site in November 2006, following completion of the Comprehensive Environmental Response, Compensation, and Liability Act environmental remediation and site restoration (with the exception of groundwater). When the site was turned over to LM, approximately 76.5 ha of the Great Miami Aquifer remained contaminated with uranium above the final remediation level of 30 μg/L. Here, uranium contamination is being removed from groundwater in the Great Miami Aquifer through a pump-and-treat operation, which is predicted to continue until 2033. Twenty extraction wells pump about 30 million liters per day. Operation of the system is impacted by iron in the groundwater that promotes iron fouling of the well pumps, motors, and screens. The design of the well field evolved over 21 years and reflected a conservative system that could respond to a wide range of pumping conditions. For instance, some of the extraction wells were sized with pumps and motors that would allow the well to pump up to 1890 L/min (500 gpm) if warranted. The added flexibility, though, came at the cost of operational efficiency. We describe the efforts that have been taken by LM since the Fernald site was transferred to LM to mitigate the operational impacts from the iron fouling aquifer conditions and improve the efficiency of the well-field operation. Variable-frequency drives were installed at six wells to replace flow control valves. Several wells with oversized pumps and motors were changed from 24-hour per day operation to 8-hour per day operation to allow the pumps to operate closer to their design flow rates. Pumps and motors were 'right-sized' at many wells to improve pumping efficiency. The process used to rehabilitate (or clean) well screens was improved, and a process was developed to clean pumps without having to pull them from the well. To reduce pressure drops, improvements were also made to the configuration of the discharge piping. A new control system was installed for each well to allow local control and local tracking of energy used. The amount of energy used daily compared to number of gallons pumped provides a method to assess pump performance and determine when action is necessary to restore well pump efficiency. Additionally, the metrics being employed to help quantify well-field efficiency improvements are described, and the benefits achieved by proactively managing the pump-and-treat operation are presented. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Efficient Mesofluidic Separation of Large Particles in nuclear slurries - 20408

Efficient and effective particle separation is essential to cleanup of many nuclear wastes. For example, particle separation may be used to accelerate settle-decant bottlenecks that limit the throughput necessary to achieve the U.S. Department of Energy waste cleanup mission in a timely manner. Particle separation may be used to protect downstream processing equipment from pulses of solids that may be encountered near (within a few feet of) liquid-solid interfaces during waste transfer operations, thereby preventing work stoppages. Effective particle separation may permit efficient sludge washing. These are only a few of the ways in which particle separation is important. Yet, efficient and effective particle separation in nuclear processing environments remains challenging. For example, settle-decant operations permit larger and heavier particles to settle, leaving smaller, lighter particles suspended. However, settle-decant operations are slow, convection currents may resuspend solids, hindered settling of multicomponent slurries remains incompletely understood, and predictive models for settling in graduated cylinders fail to match limited observations of settling in large waste tanks. Additionally, pumping operations can cause turbulent resuspension of particles when the pump intake is close to the settled solids layer. Filtration techniques that use membranes or partially permeable barriers retain larger particles, permitting smaller particles to permeate. However, filters, including dead-end filtration, are prone to clogging and caking, operate at elevated pressures due to minimal void volume, and increase in pressure during operations, which require more control systems. Therefore, the need for high throughput particle separation techniques that operate with modest pressure drops persists. A novel mesofluidic separator presents the opportunity to effectively and efficiently accelerate the waste cleanup mission. The separator separates large particles from process streams across a broad range of particle sizes and has no moving parts or media to replace, regenerate, or clean. This separator design has an unusually large void volume, permitting operation at much higher flow rates (and lower pressures) than traditional filtration (e.g., dead-end filtration). Industrial-scale flow rates have been demonstrated. In performance testing, mesofluidic separators operate at might flow rates (>90 gpm (0.0006 m{sup 3}/s) in piping 3 inches (0.08 m) in diameter; Re>10{sup 5}), with modest pressure drop (∼25 psi (170 KPa) in testing). In complex, aggregating waste simulants, the separator loses <25% of flow projected over months without back pulsing or chemical cleaning. Mesofluidic separation presents infrastructure advantages, reduces risk, and provides mission impact. Infrastructure advantages include implementation within existing transfer systems, plug and play without facility modifications to safety systems, and operation at low pressures. The separator is flexible in location, may be positioned within or outside of waste tanks, and may replace or augment dead-end and cross-flow filters. Mesofluidic separation reduces risk by minimizing waste (no media to replace or regenerate and no cleaning chemicals to handle and dispose) and by minimizing filter change-out consistent with as low as reasonably achievable (ALARA) exposure to workers. The potential mission impact of these separators is substantial. The separator has potential to support, simplify, and accelerate in-farm transfers and waste feed delivery. Furthermore, the separator can free up settling and holding tanks in the Direct Feed Low-Activity Waste (DFLAW) mission by reducing or eliminating post-transfer settling and wait times with the potential to free up 1 Mgal (4000 m{sup 3}) of double-shell tank space. This paper quantitatively compares mesofluidic separation to dead-end filtration, discusses scale-up results, and considers the separator's potential to efficiently and effectively reduce the long-term environmental ability of particulate-rich nuclear wastes. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Preliminary Development of a Drift-Flux Model Based Pin-Resolved Core Thermal-Hydraulic Code for Dedicated Use in Efficient High-Fidelity Neutronics Coupled Calculations

As the high-fidelity multiphysics coupled core calculation becomes more practical with the advent of high-performance computing technology, efficient coupling of a neutronics code with a thermal-hydraulic (T/H) code at the pin level poses a new challenge. The COBRA-TF (CTF) code which is one of the well-known subchannel analysis codes based on the two-fluid, three-field model was coupled with many neutron transport codes such as MPACT, TORTTD, and nTRACER due to the easiness of coupling by its well-established coupling interface. Nevertheless, the calculation efficiency of such coupled codes is not satisfactory because of the heavy computational burden of CTF. The MATRA subchannel analysis code of KAERI which is based on the homogeneous equilibrium model (HEM) was coupled with neutronics codes as well. The choice of the HEM and the marching scheme in MATRA reduces the computational burden significantly. However, the applicability of the HEM for the two-phase flow conditions is limited to normal operating conditions of pressurized water reactors (PWRs) and therefore a better model which would allow wider applicability than HEM is necessary in order to deal with the core states involving nontrivial voiding. The drift-flux model (DFM) which uses 5 equations for two-fluid analyses by adopting the mixture velocity instead of two phasic velocities can be a good compromise between the two-fluid model and the HEM. With the DFM, the computational cost can be reduced and moreover the modeling of the interfacial area constitutive relations can be avoided. The phase separation for the mixture velocity can be incorporated by using the drift-flux parameters, C0 and Vgj, which can be obtained by using empirical formulas. Several subchannel codes such as WOSUB and ASSERT were developed based on the DFM. It was also adopted in some system analysis codes such as RETRAN3D. In the work here, the development of a DFM based pin-resolved T/H analysis code, ESCOT (Efficient Simulator of Core Thermal-hydraulics), is introduced for the use in efficient coupled calculations with a high-fidelity neutronics code. The field equations and the numerical methods are briefly described. Then the efficiency tests of various linear system solvers including the Krylov subspace methods (KSMs) are presented. A test problem is solved by ESCOT, MATRA and CTF for performance comparison and validation. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

GeoLoRA: Geometric integration for parameter efficient fine-tuning

Low-Rank Adaptation (LoRA) has become a widely used method for parameter-efficient fine-tuning of large-scale, pre-trained neural networks. However, LoRA and its extensions face several challenges, including the need for rank adaptivity, robustness, and computational efficiency during the fine-tuning process. We introduce GeoLoRA, a novel approach that addresses these limitations by leveraging dynamical low-rank approximation theory. GeoLoRA requires only a single backpropagation pass over the small-rank adapters, significantly reducing computational cost as compared to similar dynamical low-rank training methods and making it faster than popular baselines such as AdaLoRA. This allows GeoLoRA to efficiently adapt the allocated parameter budget across the model, achieving smaller low-rank adapters compared to heuristic methods like AdaLoRA and LoRA, while maintaining critical convergence, descent, and error-bound theoretical guarantees. The resulting method is not only more efficient but also more robust to varying hyperparameter settings. We demonstrate the effectiveness of GeoLoRA on several state-of-the-art benchmarks, showing that it outperforms existing methods in both accuracy and computational efficiency.

Schotthoefer, Steffen [ORNL] (ORCID:00000002156965↗

Systems Innovation: Modernization & Efficiencies for ESH&Q Reviews

Environmental compliance reviews at INL have traditionally been managed through fragmented systems, relying on multiple spreadsheets and manual processes. This inefficiency led to time-consuming status updates and redundant tasks, such as manually sending reminder emails and transferring data from Excel to the Environmental Review Process (ERP). Initial attempts to streamline these processes using Power Automate and Excel revealed significant limitations, necessitating a more comprehensive solution. To address these immediate inefficiencies, automated workflows were developed using Power Automate. These workflows were designed to send scheduled status update reminders and capture responses through standardized forms, with submitted data flowing directly into centralized Excel trackers. This automation reduced the administrative burden, improved data accuracy, and enabled faster, more consistent reporting. Specifically, email automation achieved a 65% efficiency gain, while data integration saw a 48% improvement, resulting in 91% of project statuses being updated within two months. Despite the improvements brought by Power Automate, the fragmented nature of the review processes persisted. To further enhance efficiency and accuracy, the Integrated Review Tool (IRT) was developed. The IRT aims to centralize review initiation and connect team systems, creating an interconnected data infrastructure that preserves team autonomy while enhancing overall efficiency. This tool automates email reminders, centralizes reviews, and streamlines data integration, significantly improving the accuracy and efficiency of environmental compliance reviews. The design and development of the IRT involved advanced systems methodology, process mapping, project management, and collaboration with subject matter experts. The minimum viable product design is 100% complete, and system development is currently underway, with expected outcomes including a centralized entry point for all ESH&Q reviews, automated routing, real-time tracking and analytics, AI integration, and a user-friendly interface. This project demonstrates the potential of leveraging automation and integrated systems to enhance efficiency, accuracy, and decision-making in environmental reporting and compliance processes at INL.

99 - GENERAL AND MISCELLANEOUS↗