Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “EFFICIENCY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

ytopt: Autotuning Scientific Applications for Energy Efficiency at Large Scales

As we enter the exascale computing era, efficiently utilizing power and optimizing the performance of scientific applications under power and energy constraints has become critical and challenging. We propose a low-overhead autotuning framework to autotune performance and energy for various hybrid MPI/OpenMP scientific applications at large scales and to explore the tradeoffs between application runtime and power/energy for energy efficient application execution, then use this framework to autotune four ECP proxy applications—XSBench, AMG, SWFFT, and SW4lite. Our approach uses Bayesian optimization with a Random Forest surrogate model to effectively search parameter spaces with up to 6 million different configurations on two large-scale HPC production systems, Theta at Argonne National Laboratory and Summit at Oak Ridge National Laboratory. The experimental results show that our autotuning framework at large scales has low overhead and achieves good scalability. Using the proposed autotuning framework to identify the best configurations, we achieve up to 91.59% performance improvement, up to 21.2% energy savings, and up to 37.84% EDP (energy delay product) improvement on up to 4096 nodes.

Autotuning↗

Non-destructive, whole-plant phenotyping reveals dynamic changes in water use efficiency, photosynthesis, and rhizosphere acidification of sorghum accessions under osmotic stress

Noninvasive phenotyping can quantify dynamic plant growth processes at higher temporal resolution than destructive phenotyping and can reveal phenomena that would be missed by end-point analysis alone. Additionally, whole-plant phenotyping can identify growth conditions that are optimal for both above- and below-ground tissues. However, noninvasive, whole-plant phenotyping approaches available today are generally expensive, complex, and non-modular. We developed a low-cost and versatile approach to noninvasively measure whole-plant physiology over time by growing plants in isolated hydroponic chambers. We demonstrate the versatility of our approach by measuring whole-plant biomass accumulation, water use, and water use efficiency every two days on unstressed and osmotically stressed sorghum accessions. We identified relationships between root zone acidification and photosynthesis on whole-plant water use efficiency over time. Our system can be implemented using cheap, basic components, requires no specific technical expertise, and should be suitable for any non-aquatic vascular plant species.

59 BASIC BIOLOGICAL SCIENCES↗

Lithium–Metal Batteries via Suppressing Li Dendrite Growth and Improving Coulombic Efficiency

Lithium–metal batteries (LMB) are recognized as one of the most promising candidates for the next generation of batteries due to their high energy density. Extensive studies have been refocused on the field in the past decade to make the technology commercially viable. Unfortunately, despite exciting progress that has been made, the practical application of LMBs is still hampered by the uncontrollable Li plating morphology and inferior Coulombic efficiency (CE) during cycling. Herein, first, the relevant research that has been carried out in the past decade (2010–2021) is briefly summarized and then the Li plating behaviors, mechanistic understanding of these behaviors, and strategies to suppress Li dendrite growth are discussed. Finally, the methods and techniques to improve Coulombic efficiency (CE) is discussed, especially the design of liquid electrolytes, and possible research directions for the future development of LMBs.

25 ENERGY STORAGE↗

Light output and neutron detection efficiency of boron-based neutron scintillator screens for neutron imaging

Recent research has explored the development of boron-based neutron scintillator screens, which potentially offer improved spatial resolution and neutron capture efficiency compared to traditional lithium-based screens. This work builds upon previous efforts to improve boron-based neutron scintillators by assessing a newer generation of boron-based scintillator screens fabricated using different compositions and fabrication approaches compared to previous generations of screens. Some of the test screens exhibit higher light output than previous efforts and higher neutron capture efficiency than lithium-based screens. This paper describes the current state of screen development, measurement results for the most recent generation of screens, and future activities.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Pathways to commercial building plug and process load efficiency and control

Abstract To accomplish net-zero carbon emissions in the built environment by 2050, we must equitably decarbonize commercial buildings, including reducing plug and process loads (PPLs). PPLs are plug-in or hardwired electric and gas loads that are not associated with major building end uses like lighting and HVAC. Research shows PPL energy reduction strategies and control technologies have the potential to save energy. But even when implemented, these savings have rarely been achieved and there has not been widespread uptake in U.S. commercial buildings. We investigate why these technologies and strategies have not seen widespread adoption and identify behavior and technology pathways to increase PPL reduction in U.S. commercial buildings. We examined behaviors of commercial building stakeholders through 44 interviews and cross-referenced qualitative analysis findings with in-depth technical knowledge of existing PPL control technologies and reduction strategies. PPL control implementation must be paired with management strategies, such as occupant engagement and training, to achieve optimal savings, and best practices should be disseminated across the industry. We found that increasing access to cost and energy savings data will promote uptake of PPL control technologies and allow designers to better incorporate PPLs into building design. Improving access to funding for PPL energy efficiency projects and addressing the split-incentive problem will increase adoption of PPL efficiency and control. Code bodies should continue to include PPL monitoring and reduction measures in energy codes. Key building stakeholders, including cybersecurity and information technology teams, should be involved in PPL monitoring and reduction strategy processes for successful implementation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Electrifying High-Efficiency Future Communities: Impact on Energy, Emissions, and Grid

To combat climate change and meet decarbonization goals, the building sector is improving energy efficiency and electrifying end uses to reduce carbon emissions from fossil fuels. All-electric buildings are becoming a trend among new constructions, introducing opportunities for decarbonization but also technical challenges and research gaps. For instance, further investigation is needed to understand how the adoption of energy efficiency measures (EEMs) and distributed energy resources (DERs) in all-electric communities would affect energy consumption, carbon emissions, and grid planning. This paper presents a case study of a mixed-use, all-electric community located in Denver, Colorado. We use URBANopt TM , a physics-based urban energy modeling platform to model the community and then evaluate the impact of EEMs and DERs (i.e., photovoltaics [PV], electric vehicles [EVs], and batteries) on the community's energy usage, carbon emissions, and peak demand. The results show that adding EEMs and PV led to both energy consumption and carbon emissions reductions across all building types. However, we saw fairly limited impact of EEMs and PV on buildings' peak demand in our case. Additionally, due to overnight EV charging activities and higher grid carbon intensity at night, the carbon emissions in multifamily buildings have a noticeable increase compared to scenarios without vehicles. Finally, the addition of batteries helped reduce peak demand by 11%-29%. The modeling workflow and evaluation methods can be applied to similar communities to evaluate their performance and the effect of integrating EEMs and DERs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Environment-sensitivity functions for gross primary productivity in light use efficiency models

The sensitivity of photosynthesis to environmental changes is essential for understanding carbon cycle responses to global climate change and for the development of modeling approaches that explains its spatial and temporal variability. We collected a large variety of published sensitivity functions of gross primary productivity (GPP) to different forcing variables to assess the response of GPP to environmental factors. These include the responses of GPP to temperature; vapor pressure deficit, some of which include the response to atmospheric CO 2 concentrations; soil water availability (W); light intensity; and cloudiness. These functions were combined in a full factorial light use efficiency (LUE) model structure, leading to a collection of 5600 distinct LUE models. Each model was optimized against daily GPP and evapotranspiration fluxes from 196 FLUXNET sites and ranked across sites based on a bootstrap approach. The GPP sensitivity to each environmental factor, including CO 2 fertilization, was shown to be significant, and that none of the previously published model structures performed as well as the best model selected. From daily and weekly to monthly scales, the best model's median Nash-Sutcliffe model efficiency across sites was 0.73, 0.79 and 0.82, respectively, but poorer at annual scales (0.23), emphasizing the common limitation of current models in describing the interannual variability of GPP. Although the best global model did not match the local best model at each site, the selection was robust across ecosystem types. The contribution of light saturation and cloudiness to GPP was observed across all biomes (from 23% to 43%). Temperature and W dominates GPP and LUE but responses of GPP to temperature and W are lagged in cold and arid ecosystems, respectively. The findings of this study provide a foundation towards more robust LUE-based estimates of global GPP and may provide a benchmark for other empirical GPP products.

54 ENVIRONMENTAL SCIENCES↗

Controlling distributed energy resources via deep reinforcement learning for load flexibility and energy efficiency

Behind-the-meter distributed energy resources (DERs), including building solar photovoltaic (PV) technology and electric battery storage, are increasingly being considered as solutions to support carbon reduction goals and increase grid reliability and resiliency. However, dynamic control of these resources in concert with traditional building loads, to effect efficiency and demand flexibility, is not yet commonplace in commercial control products. Traditional rule-based control algorithms do not offer integrated closed-loop control to optimize across systems, and most often, PV and battery systems are operated for energy arbitrage and demand charge management, and not for the provision of grid services. More advanced control approaches, such as MPC control have not been widely adopted in industry because they require significant expertise to develop and deploy. Recent advances in deep reinforcement learning (DRL) offer a promising option to optimize the operation of DER systems and building loads with reduced setup effort. However, there are limited studies that evaluate the efficacy of these methods to control multiple building subsystems simultaneously. Additionally, most of the research has been conducted in simulated environments as opposed to real buildings. This paper proposes a DRL approach that uses a deep deterministic policy gradient algorithm for integrated control of HVAC and electric battery storage systems in the presence of on-site PV generation. The DRL algorithm, trained on synthetic data, was deployed in a physical test building and evaluated against a baseline that uses the current best-in-class rule-based control strategies. Performance in delivering energy efficiency, load shift, and load shed was tested using price-based signals. The results showed that the DRL-based controller can produce cost savings of up to 39.6% as compared to the baseline controller, while maintaining similar thermal comfort in the building. The project team has also integrated the simulation components developed during this work as an OpenAIGym environment and made it publicly available so that prospective DRL researchers can leverage this environment to evaluate alternate DRL algorithms.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Association of residential energy efficiency retrofits with indoor environmental quality, comfort, and health: A review of empirical data

This paper reviews empirical data from evaluations of the influence of residential energy efficiency retrofits on indoor environmental quality conditions and self-reported thermal comfort and health. The data were extracted from 36 studies described in 44 papers plus two reports. Nearly all reviewed studies were performed in Europe or United States. Most studies evaluated retrofits of homes with low-income occupants. Indoor radon and formaldehyde concentrations tended to increase after retrofits that did not add whole-house mechanical ventilation. Study-average indoor concentrations of nitrogen dioxide and volatile organic compounds other than formaldehyde increased and decreased with approximately equal frequency. Average indoor temperatures during winter typically increased after retrofits, usually by less than 1.5 °C. Dampness and mold, usually based on occupant's reports, almost always decreased after retrofits. Subjectively reported thermal comfort, thermal discomfort, non-asthma respiratory symptoms, general health, and mental health nearly always improved after retrofits. For asthma symptoms, the evidence of improvement slightly outweighed the evidence of worsening. There was insufficient evidence to determine whether changes in thermal comfort and health outcomes varied depending on the type of energy efficiency retrofit. The published research has numerous limitations including a lack of data from retrofits in warm-humid climates and minimal data on changes in objective health outcomes. Suggestions for future research are provided.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Air quality and comfort constrained energy efficient operation of multi-zone buildings

Maintaining indoor air quality (IAQ) through effective ventilation is essential for the well-being and productivity of building occupants. Control strategies aimed at improving the efficiency of heating, ventilation and air conditioning (HVAC) systems must jointly determine ventilation and heating and cooling processes. Here, in this paper, we study the problem of minimizing the energy consumption of the HVAC system in a multi-zone building, while meeting thermal comfort and IAQ requirements. We first perform a steady state analysis of the zonal carbon dioxide (CO 2 ) concentration and the temperature dynamics. The resulting expressions are convex in the zonal mass flow rates and zonal temperatures. Guided by the steady state solutions for meeting the thermal comfort constraints, we develop two control policies for improving the energy efficiency of building HVAC systems while jointly satisfying indoor temperature and IAQ constraints. We compare the performance of our proposed approaches with those of multiple baseline approaches which implement separate regimes for controlling zonal temperature and IAQ for a typical work-day in a multi-zone campus building. We have evaluated the performance of our proposed approaches under varying levels of flexibility in zonal temperatures. We have shown that zonal temperature flexibility can result in energy savings up to 32% (for the same control strategies) as compared to the case where no such flexibility is permitted. Our proposed approaches were seen to offer potential savings of nearly 29% compared to the baseline.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy efficiency and thermal resilience analysis for row houses using representative building energy models

Row houses, a prevalent medium-density urban archetype, were popularized during industrial era to accommodate the working class in the U.S. cities. Today, many of these structures are deteriorating, exacerbating the energy cost for residents with limited economic resources. Moreover, many households that lack Air Conditioning (AC) are vulnerable to extreme summer heat, an issue expected to worsen in the future. Energy-efficient retrofits can help mitigate these challenges. However, current literature provides limited insight into how existing building energy codes impact the energy efficiency and thermal resilience of row houses in current and future weather scenarios. This study provides a detailed method to address this gap by employing calibrated representative energy models of row houses as a baseline, and evaluating the annual energy savings and summertime thermal safety improvements from code compliant retrofits under current and future typical weather conditions. Using Baltimore City as a case study, results show that under current weather, retrofitting row houses yields significant energy savings along with notable thermal resilience improvements. The end unit row house realizes higher energy savings, whereas the interior unit experiences greater thermal resilience improvement after retrofitting. In future, retrofitted row houses can still save energy, but residents will face numerous hours of fatal indoor temperatures without AC in summer. Additionally, findings reveal stark zone-wise variations in thermal safety, and elevated humidity risks in certain zones post-retrofit, emphasizing the need for zonal retrofit strategies and better natural ventilation strategies.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Optimized molecular aggregation via incorporating fluorinated unit in the polymer donor for 17.3% efficiency organic solar cells

Regulating molecular aggregation state via chemical modification of photovoltaic materials to optimize the blend morphology is an effective and challenging strategy to improve the photovoltaic performance of organic solar cells (OSCs). Here, in this work, we demonstrate a random terpolymerization strategy by incorporating 1,3-bis(5-bromo-4-fluorothiophen-2-yl)-5,7-bis(2-ethylhexyl)-4H,8H-benzo[1,2-c:4,5-c']bisthiophene-4,8-dione (BFT, 30 mol%) unit with fluorinated π-bridges into the molecular backbone of PM6 and develop a terpolymer PF1. Benefiting from the strong electronegativity of fluorine atom and noncovalent interaction of F---S, the energy levels, molecular ordering, and aggregation properties of the polymer donors are precisely regulated. Notably, in the active layer film based on PF1: Y6, the π-π stacking distance can reduce to 3.51 Å, which is significantly smaller than that of PM6:Y6 (3.65 Å) and boosts the effective exciton dissociation and charge transport, thereby effectively optimize the photovoltaic properties of the related devices. As a result, the PF1:Y6-based OSCs achieved a power conversion efficiency (PCE) of up to 17.3%, which is much higher than that of the controlled OSCs based on PM6:Y6 (PCE = 16.2%). These results demonstrate high-efficiency OSCs enabled by regulating molecular aggregation via terpolymerization strategy.

14 SOLAR ENERGY↗

Siloxane-functional small molecule acceptor for high-performance organic solar cells with 16.6% efficiency

As one of the simple but most effective molecular design strategies, side-chain engineering has been widely employed to modify the photoelectric properties of active layer materials for boosting the photovoltaic performance of organic solar cells (OSCs). In this work, a functionalized small molecule acceptor (SMA) named BTSi-4F with a bulky siloxane-terminated solubilizing group as side-chains, derived from a classical SMA of Y6, was designed and synthesized. The results demonstrate that the introduction of siloxane-functional terminated groups into SMA not only affects the optical absorption and molecular energy levels, but also regulates the miscibility between the polymer donor and SMA. Compared to the original Y6, BTSi-4F exhibits a better solubility, upshifted lowest unoccupied molecular orbital (LUMO) energy level, more ordered molecular packing, and higher electron-mobility. Matched with a wide bandgap polymer donor PM6, the chlorobenzene-processed OSCs based on PM6:BTSi-4F achieved a superior power conversion efficiency (PCE) of 16.6% with both high open-circuit voltage (V oc ) of 0.90 V and high fill factor (FF) of 0.77, while the devices based on PM6:Y6 obtained a much lower PCE of 13.0% with a V oc of 0.81 V and FF of 0.69 under the same conditions. This work offers a promising molecular design strategy of siloxane-terminated side chain engineering to develop high-performance SMAs for efficient OSCs.

14 SOLAR ENERGY↗

A high-efficiency self-healing cementitious material based on supramolecular hydrogels impregnated with phosphate and ammonium

High-efficiency self-healing cementitious materials using hydroxyapatites as healing product were described. Supramolecular hydrogels impregnated with phosphate and ammonium ions were designed. Morphology of the supramolecular hydrogel and its capability to release phosphate in solution, the structure of healing products and the self-healing efficiency were characterized with a range of analytical techniques. Cracks in the cementitious materials with width up to 1 mm are closed and completely healed. The healing product in the cracks without ammonium ions was brushite with a sponge-like morphology. Released ammonium ions reacted with calcium hydroxide in the cement matrix, increasing the concentration of soluble calcium ions up to 300 times that in reference pore solution. Ammonium ions facilitated the formation and aggregation of healing products which were converted into hydroxyapatites, improving the maximum healable crack width.

36 MATERIALS SCIENCE↗

Demonstrating non-isothermal vacuum membrane air dehumidification for efficient next-generation air conditioning

Vacuum membrane air dehumidification has gained significant interest in recent years as a highly efficient means of air dehumidification. Prior theoretical modeling work by the authors introduced the Active Membrane Energy Exchanger (AMX) concept, which combines active heat exchange and vacuum membrane dehumidification into one non-isothermal system, and found that it could outperform other air conditioning technologies under many conditions. However, no experimental literature exists on combining active heat exchangers and vacuum membrane dehumidification. Here, the goal of the present study is to evaluate the dehumidification (mass transfer) performance of the AMX concept relative to isothermal membrane dehumidification through three main methodologies: (1) membrane material-level characterization, (2) experimental prototype development and testing, and (3) computational fluid dynamics (CFD) simulations. The dense membranes used in this work showed up to a 40% increase in water vapor permeance at cooler temperatures, and the prototype system showed up to a 6% increase in humidity removal when the air was simultaneously cooled. Furthermore, the membrane module-integrated heat exchange tubes provided additional mixing and turbulence, leading to a 4–8% increase in humidity removal. The upper limit coefficient of performance was equal to approximately 2.2, necessitating advanced system designs to improve efficiency. This study is the first to highlight that combining the cooling and vacuum dehumidification processes can improve dehumidification performance.

30 DIRECT ENERGY CONVERSION↗

Grid-responsive hydrogen production: Capital utilization and current density vs. efficiency in variable electricity markets

To achieve low-cost hydrogen production from water electrolyzers, grid tied electrolysis may need to operate dynamically to minimize the cost of supplying energy to the electrolyzer stack and produce hydrogen during low-cost hours and turn off/down during high-cost hours. Operating systems in this way can decrease capital utilization (capacity factor) and electricity costs. This strategy would shift the dominant cost drivers away from electricity (and thus efficiency) to the capital costs of the system, due to the underutilized capital when operating at low-capacity factors. Increasing the operational current density of the system could, in effect, reduce the capital cost of the system while producing hydrogen at a lower efficiency on a per unit energy basis. In the variable electricity cost profiles analyzed in this paper, increasing the current density for liquid alkaline from 0.5 A/cm2 to 1.5 Ac/m2 and proton exchange membrane electrolyzers from 2 A/cm2 to 4 A/cm2 resulted in substantial reductions in the levelized cost of hydrogen. Additionally, as capacity factors and electricity costs decrease, the optimal operating current density of the electrolyzer systems analyzed increases. These findings suggest R&D efforts should focus on increasing the operational current densities, reducing the turn down ratios, and understanding the durability implications of those strategies on low-temperature liquid alkaline and proton exchange membrane electrolyzers.

08 HYDROGEN↗

Magnetocaloric response with significant mechanical efficiency in frustrated intermetallic compound $\mathrm{Pr_{2}Co_{0.86}Si_{2.88}}$

We report magnetically frustrated materials are considered as a promising unconventional members of caloric materials. Here, the magnetocaloric properties of the frustrated Pr 2 Co 0.86 Si 2.88 have been investigated and discussed with the aid of density functional theory (DFT) calculations. The material exhibits a magnetic entropy change (-ΔS M ) of 13.1 J/kg-K for ΔH = 70 kOe around low-temperature transition T L ~ 4 K associated with the antiferromagnetic coupling between localized Pr-4f and itinerant Co-3d moments. Despite the absence of any long-range magnetic order, the obtained - ΔS M is one of the highest among the known Pr-based good magnetocaloric materials at cryogenic temperature range. It also exhibits a relative cooling power (RCP) of ~ 201 J/kg and an adiabatic temperature change of 6.3 K around T L at 70 kOe. Moreover, the compound also exhibits a high mechanical efficiency and moderate electrical efficiency, being beneficial for possible technological applications.

36 MATERIALS SCIENCE↗

Spontaneous sodium ion storage behaviors of reduced graphene oxide anodes exceeding 100% Coulombic efficiency by modulated ion solvation

Rechargeable batteries are essential energy storage devices that power portable devices and electrical vehicles throughout the world. In general, it is thought that the electrochemical performance of rechargeable batteries is mostly determined by the electrodes within them and that the electrolyte plays a relatively passive role. However, ion transport and storage can be greatly influenced by the electrolyte solution structure, specifically, ion solvation within the bulk and ion desolvation across the electrode/electrolyte interfaces. Herein, we studied the role of the electrolyte as an active component of electrochemical energy storage devices. We found that with an appropriate electrolyte formulation, ion storage in disordered carbonaceous anode materials can occur spontaneously without externally supplied electrical energy. Reduced graphene oxide (RGO) in an ether-based electrolyte demonstrates ‘spontaneous' ion storage behaviors of adsorbing and inserting the solvated ions utilizing facilitated permeability and wettability of RGO, which results in Coulombic efficiency of ~145% due to additional charging capacity of ~180 mAh g -1 during electrochemical processes. The unexpected spontaneous ion storage behavior was extensively investigated using a combination of electrochemical analyses and diagnostics, advanced characterizations, and computational simulation. In conclusion, we believe the spontaneous ion storage behavior offers a new way to further improve the energy efficiency of practical rechargeable batteries.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗