At least 1,459 records · Page 81

Search for in-band transitions in the candidate superdeformed band in Si 28

Background: Superdeformed (SD) bands are suggested by theory around Ca 40 and in lighter alpha-conjugate nuclei such as Mg 24 , Si 28 , and S 32 . Such predictions originate from a number of theoretical models including mean-field models and antisymmetrized molecular dynamics (AMD) calculations. While SD bands have been identified in Ca 40 and its near neighbors, evidence of their existence in the lighter, midshell nuclei is circumstantial at best. Additionally, the key evidence of superdeformation would be the observation of transitions with high B ( E 2 ) transition strengths connecting states in a rotational sequence. This is challenging information to obtain since the bands lie at a high excitation energy and competition from out-of-band decay is dominant. Purpose: The purpose of the present study is to establish a new methodology to circumvent the difficulties in identifying and quantifying in-band transitions through directly populating candidate states in the SD band in Si 28 through inelastic alpha scattering, selecting such states with a spectrometer, and measuring their gamma-ray decay with a large array of high-purity germanium detectors, allowing direct access to electromagnetic transition strengths. Methods: Excited states in Si 28 were populated in the Si 28 ( α , α ' ) reaction using a 130-MeV He 4 beam from the K140 AVF cyclotron at the Research Center for Nuclear Physics. Outgoing alpha particles were analyzed using the Grand Raiden spectrometer positioned at an angle of 9 . 1 ° to favor the population of states with J ≈ 4 . Coincident gamma rays were detected with the CAGRA array of 12 HPGe clover detectors augmented by a set of four large LaBr 3 detectors. Results: Data analysis showed that it was possible to identify additional low-energy transitions in competition with high-energy decays from excited states in Si 28 in the vicinity of 10 MeV. However, while the candidate 4 + SD state at 10.944 MeV was populated, a 1148-keV transition to the candidate 2 + SD state at 9.796 MeV was not observed, and only an upper limit for its transition strength of B ( E 2 ) < 43 W.u. could be established. This contradicts AMD predictions of ≈ 200 W.u. for such a transition. Conclusion: The present study strongly rejects the hypothesis that the candidate set of states identified in Si 28 represents an SD band, which demonstrates the potential of the methodology devised here.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High-Performance LWIR Superlattice Detectors and FPA Based on CBIRD Design

We report our recent efforts on advancing of antimonide superlattice based infrared photodetectors and demonstration of focal plane arrays based on a complementary barrier infrared detector (CBIRD) design. By optimizing design and growth condition we succeeded to reduce the operational bias of CBIRD single pixel detector without increase of dark current or degradation of quantum efficiency. We demonstrated a 1024x1024 pixel long-waveleng thinfrared focal plane array utilizing CBIRD design. An 11.5 micrometer cutoff focal plane without anti-reflection coating has yielded noise equivalent differential temperature of 53 mK at operating temperature of 80 K, with 300 K background and cold-stop. Imaging results from a recent 10 micrometer cutoff focal plane array are also presented. These results advance state-of-the art of superlattice detectors and demonstrated advantages of CBIRD architecture for realization of FPA.

infrared↗

High-Performance LWIR Superlattice Detectors and FPA Based on CBIRD Design

We report our recent efforts on advancing of antimonide superlattice based infrared photodetectors and demonstration of focal plane arrays based on a complementary barrier infrared detector (CBIRD) design. By optimizing design and growth condition we succeeded to reduce the operational bias of CBIRD single pixel detector without increase of dark current or degradation of quantum efficiency. We demonstrated a 1024x1024 pixel long-wavelength infrared focal plane array utilizing CBIRD design. An 11.5 micrometer cutoff focal plane without anti-reflection coating has yielded noise equivalent differential temperature of 53 mK at operating temperature of 80 K, with 300 K background and cold-stop. Imaging results from a recent 10 micrometer cutoff focal plane array are also presented. These results advance state-of-the art of superlattice detectors and demonstrated advantages of CBIRD architecture for realization of FPA.

heterostructure↗

A diffraction-limited far-infrared imager for the KAO

We describe both our current instrument and a follow-on instrument expected to be operational at the start of the next flight year on the KAO. The current instrument uses a 20-channel bolometer array arranged in two columns of 10 detectors each. Broadband observations can be made at the true diffraction limit, lambda/2D, at either 50 or 100 microns during a flight. Our forthcoming system will use two arrays of 3 x 10 detectors to enable simultaneous imaging at both 50 and 100 microns at the KAO diffraction limit for each wavelength. Observing modes and typical sensitivities will be discussed.

Harvey, Paul M.↗

Anomaly Detection for the Roman Space Telescope Wide Field Instrument’s Science Data Processing Pipeline

The Roman Space Telescope (RST) Wide Field Instrument (WFI) will be utilizing a preliminary Science Data Processing (SDP) pipeline during its Integration and Test, and to some extent during Operations, to track basic statistics and identify known features such as cosmic rays, snowballs as well as possible anomalies in raw detector data. In our detectors, these anomalies appear as jumps in the ramp of a readout and are classified as cosmic rays if they appear as a streak or snowballs if they’re more circular. The WFI employs an array of 18 H4RG-10 detectors that collect image samples. Each set of raw frames within a non-destructive exposure is packaged by the SDP pipeline into image cubes for each detector. Each cube is a time series of 4096 × 4096 accumulating pixel frames. The preliminary analysis pipeline is used to locate anomalies in these time-series accumulation frames and identify the type of anomaly, either natural phenomena or detector characteristic. To compare different methods, we’ve implemented both heuristic-based and data-driven methods to identify anomalies. For the heuristic-based approach, we identify snowballs and cosmic rays by the size and shape of outlier pixel clusters between consecutive frames. For data driven methods, we evaluated a Convolutional Neural Network (CNN) model, and more traditional methods like Principal Component Analysis (PCA). CNN is a supervised learning/classification method. Thus, we used a labeled dataset of anomalies to perform segmentation of the image and identify anomalies. We used previously identified cosmic rays and snowballs to measure the accuracy and efficiency of the mentioned approaches. In evaluating these methods, we aim to pick the best fit for the SDP pipeline’s anomaly detection in terms of both performance and runtime.

Paul Horton↗

Ideal Integrating Bolometer

We describe a new 'ideal integrator' bolometer as a prototype for a new generation of sensitive, flexible far-IR detectors suitable for use in large arrays. The combination of a non-dissipative sensor coupled with a fast heat switch provides breakthrough capabilities in both sensitivity and operation. The bolometer temperature varies linearly with the integrated infrared power incident on the detector, and may be sampled intermittently without loss of information between samples. The sample speed and consequent dynamic range depend only on the heat switch reset cycle and can be selected in software. Between samples, the device acts as an ideal integrator with noise significantly lower than resistive bolometers. Since there is no loss of information between samples, the device is well-suited for large arrays. A single SQUID readout could process an entire column of detectors, greatly reducing the complexity, power requirements, and cost of readout electronics for large pixel arrays.

Kogut, Alan↗

Ideal Integrating Bolometer

We describe a new "ideal integrator" bolometer as a prototype for a new generation of sensitive, flexible far-IR detectors suitable for use in large arrays. The combination of a non-dissipative sensor coupled with a fast heat switch provides breakthrough capabilities in both sensitivity and operation. The bolometer temperature varies linearly with the integrated infrared power incident on the detector, and may be sampled intermittently without loss of information between samples. The sample speed and consequent dynamic range depend only on the heat switch reset cycle and can be selected in software. Between samples, the device acts as an ideal integrator with noise significantly lower than resistive bolometers. Since there is no loss of information between samples, the device is well-suited for large arrays. A single SQUID readout could process an entire column of detectors, greatly reducing the complexity, power requirements, and cost of readout electronics for large pixel arrays.

Kogut, A.↗

High throughput reconfigurable data analysis system

The present invention relates to a system and method for performing rapid and programmable analysis of data. The present invention relates to a reconfigurable detector comprising at least one array of a plurality of pixels, where each of the plurality of pixels can be selected to receive and read-out an input. The pixel array is divided into at least one pixel group for conducting a common predefined analysis. Each of the pixels has a programmable circuitry programmed with a dynamically configurable user-defined function to modify the input. The present detector also comprises a summing circuit designed to sum the modified input.

Bearman, Greg↗

Si/IrSi3 Schottky-Barrier Infrared Detectors

Si/IrSi or Si/IrSi3 Schottky-barrier detector fabricated by stoichiometric codeposition of Ir and Si on p Si substrate. Includes p+ substrate contact, silicide electrode, and n Si guard ring, which suppresses leakage around periphery of silicide electrode. Part of continuing effort to develop imaging arrays of Schottky-barrier detectors operating at far-infrared wavelengths.

Lin, True-Lon↗

MARE-l in Milan: Status and Perspectives

The international project MARE (Microcalorimeter Array for a Rhenium Experiment) aims at the direct and calorimetric measurement of the electron neutrino mass with sub-eV sensitivity. Although the baseline of the MARE project consists in a large array of rhenium based thermal detectors, a different option for the isotope is also being considered. The different option is Ho-163. The potential of using Re-187 for a calorimetric neutrino mass experiment has been already demonstrated. On the contrary, no calorimetric spectrum of Ho-163 has been so far measured with the precision required to set a useful limit on the neutrino mass. The first phase of the project (MARE-1) is a collection of activities with the aim of sorting out both the best isotope and the most suited detector technology to be used for the final experiment. One of the MARE-1 activities is carried out in Milan by the group of Milano-Bicocca in collaboration with NASA/GSFC and Wisconsin groups. The Milan MARE-l arrays are based on semiconductor thermistors, provided by the NASA/GSFC group, with dielectric silver perrhenate absorbers, AgReO4. The experiment, which is presently being assembled, is designed to host up to 8 arrays.

Ferri, E.↗

Event sequence detector

An event sequence detector is described with input units, each associated with a row of bistable elements arranged in an array of rows and columns. The detector also includes a shift register which is responsive to clock pulses from any of the units to sequentially provide signals on its output lines each of which is connected to the bistable elements in a corresponding column. When the event-indicating signal is received by an input unit it provides a clock pulse to the shift register to provide the signal on one of its output lines. The input unit also enables all its bistable elements so that the particular element in the column supplied with the signal from the register is driven to an event-indicating state.

Hanna, M. F.↗

Gaia: segmented germanium detector for high-energy X-ray fluorescence and spectroscopic imaging

We present Gaia, a monolithic array of 96 high-purity germanium pixel detectors integrated with a custom low-noise application-specific integrated circuit (ASIC) and a field-programmable gate array (FPGA)-based data acquisition system. The sensor operates at ∼100 K using a commercial closed-cycle cryocooler, with the in-vacuum electronics thermally isolated from the cold finger to ensure thermal stability. The system demonstrates an average energy resolution of 711 eV at 122 keV, measured using a 57 Co source, and 253 eV at 5.89 keV, measured with 55 Fe across all channels. The readout architecture incorporates a high-performance FPGA paired with a dual-core ARM processor, forming a complete embedded Linux-based computing platform. Communication between the processor and FPGA is handled via memory-mapped I/O, and data are streamed over high-speed gigabit Ethernet. A full-scale 384-pixel Gaia detector, based on this 96-element module, is currently under fabrication.

36 MATERIALS SCIENCE↗

SiAl Alloy Feedhorn Arrays: Material Properties, Feedhorn Design, and Astrophysical Applications

We present here a study of the use of the SiAl alloy CE7 for the packaging of silicon devices at cryogenic temperatures. We report on the development of baseplates and feedhorn arrays for millimeter wave bolometric detectors for astrophysics. Existing interfaces to such detectors are typically made either of metals, which are easy to machine but mismatched to the thermal contraction profile of Si devices, or of silicon, which avoids the mismatch but is difficult to directly machine. CE7 exhibits properties of both Si and Al, which makes it uniquely well suited for this application. We measure CE7 to a) superconduct below a critical transition temperature, T (sub c), 1.2 K, b) have a thermal contraction profile much closer to Si than metals, which enables simple mating, and c) have a low thermal conductivity which can be improved by Au-plating. Our investigations also demonstrate that CE7 can be machined well enough to fabricate small structures, such as #0-80 threaded holes, to tight tolerances (approximately 25 microns) in contrast with pure silicon and similar substrates. We have fabricated CE7 baseplates being deployed in the 93 gigahertz polarimetric focal planes used in the Cosmology Large Angular Scale Surveyor (CLASS). We also report on the development of smooth-walled feedhorn arrays made of CE7 that will be used in a focal plane of dichroic 150/220 gigahertz detectors for the CLASS High-Frequency camera.

Ali, Aamir M.↗

The STIS MAMA status: Current detector performance

The STIS (Space Telescope Imaging Spectrograph) is a second generation Hubble instrument scheduled to fly in 1997. Through a variety of modes, the instrument will provide spectral resolutions from R approximately 50 in the objective spectroscopy mode to 100,000 in the high resolution echelle mode in the wavelength region from 115 to 1000 nm. In the UV the instrument employs two MAMA (Multimode Anode Microchannel plate Arrays) 1024 by 1024 pixel detectors, which provide high DQE (Detective Quantum Efficiency), and good dynamic range and resolution. The current progress and performance of these detectors are reported, illustrating that the technology is mature and that the performance is very close to flight requirements.

Danks, A. C.↗

Characterization of a Pixelated Cadmium Telluride Detector System Using a Polychromatic X-Ray Source and Gold Nanoparticle-Loaded Phantoms for Benchtop X-Ray Fluorescence Imaging

In this paper, the imaging dose and scan time have been considered as the two major constraints for routine benchtop x-ray fluorescence computed tomography (XFCT) imaging. One way to address this issue is to acquire x-ray fluorescence (XRF) signals in parallel through a 2D array of single-crystal detectors or a pixelated detector along with the cone-beam x-ray source. To identify a detector system suitable for this purpose, a commercially available, fully spectroscopic cadmium telluride (CdTe) pixelated detector, HEXITEC (High-Energy X-ray Imaging Technology), was tested under the experimental conditions optimized for benchtop XFCT imaging of gold nanoparticles (GNPs). Specifically, two different parallel-hole stainless steel collimators were fabricated and coupled with the detector for seamless integration into our existing benchtop cone-beam XFCT system. After the detector deployment, this benchtop XFCT system was used to detect XRF photons from GNP-loaded phantoms. A pixel-merging algorithm was introduced to enhance the sensitivity of XRF photon detection thereby minimizing the scan time. The effect of pixel-level charge sharing correction algorithms was investigated within the context of benchtop XFCT imaging. The detector energy resolution, in terms of the full width at half maximum (FWHM) values at different gold K-shell XRF energies, was also determined. Of the two charge sharing correction algorithms examined, the charge sharing addition gave better sensitivity than the charge sharing discrimination (csd). On the other hand, under the current experimental conditions, the energy resolution of the HEXITEC detector was the best with the csd and estimated to be 1.56 keV FWHM at 66-69 keV photon energy. Overall, despite some degradation of the detector energy resolution (compared with typical single crystal CdTe detectors), the HEXITEC detector enabled parallel data acquisition under the experimental conditions typical of benchtop XFCT imaging and operated well within our benchtop XFCT setup.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Infrared Astronomy with Arrays: The Next Generation; Sunset Village, Los Angeles, CA, Oct. 1993

Conference papers on infrared array techniques and methods for infrared astronomy are presented. Topics covered include the following: infrared telescopes; infrared spectrometers; spaceborne astronomy; astronomical observatories; infrared cameras; imaging techniques; sky surveys; infrared photography; infrared photometry; infrared spectroscopy; equipment specifications; data processing and analysis; control systems; cryogenic equipment; adaptive optics; image resolution; infrared detector materials; and focal plane arrays.

Mclean, Ian S.↗

Flight Integral Field Spectrograph (IFS) Optical Design for WFIRST Coronagraphic Exoplanet Demonstration

Based on the experience from Prototype Imaging Spectrograph for Coronagraphic Exoplanet Studies (PISCES) for WFIRST, we have moved to the flight instrument design phase. The specifications for flight IFS have similarities and differences from the prototype. This paper starts with the science and system requirement, discusses a number of critical trade-offs: such as IFS type selection, lenslet array shape and layout versus detector pixel accuracy, how to accommodate the larger Field Of View (FOV) and wider wavelength band for a potential add-on StarShade occulter. Finally, the traditional geometric optical design is also investigated and traded: reflective versus refractive, telecentric versus non-telecentric relay. The relay before the lenslet array controls the chief angle distribution on the lenslet array. Our previous paper has addressed how the relay design combined with lenslet arraypinhole mask can further compress the residual star light and increase the contrast. Finally, a complete phase A IFS optical design is presented.

Integral Field spectrograph↗