Visualization studies of turbulent transition flows in a porous medium

Results are reported for flow-visualization studies of the flow regimes of water passing through a porous medium consisting of cylindrical glass and plexiglas rods arranged in a complex and fixed three-dimensional geometry. The Reynolds number (Re) varied from 50 to 700; the flow was visualized by injecting a 5% potassium permanganate dye solution into the pores and photographing the resulting dye streaklines with both a still camera and a movie camera. The results indicate that four distinct flow regimes exist in the porous medium: (1) Darcy or creeping flow up to Re = 3; (2) steady inertia-dominated laminar flow for Re = 3-150; (3) unsteady transitional laminar flow for Re = 150-250; and (4) fully turbulent flow for Re greater than 250. It is concluded that a laminar wake instability mechanism typical of the external flow about bluff bodies may be responsible for the overall transition from laminar to turbulent flow in porous media.

Bilardo, V. J.↗

Remote sensing of tropospheric gases and aerosols with airborne DIAL system

The multipurpose airborne DIAL system developed at NASA Langley Research Center is characterized, and the published results of tropospheric O3, H2O, and aerosol-backscatter remote-sensing experiments performed in 1980 and 1981 are summarized. The system comprises two tunable dye lasers pumped by frequency-doubled Nd:YAG lasers, dielectric-coated steering optics, a 36-cm-diameter Cassegrain receiver telescope, gateable photomultiplier tubes, and a minicomputer data-processing unit for real-time calculation of gas concentrations and backscattering profiles. The transmitted energy of the 100-microsec-separated dye-laser pulses is 40, 80, or 50 mJ/pulse at around 300, 600, or 720-nm wavelength, respectively. Good agreement was found between DIAL-remote-sensed and in-situ H2O and O3 profiles of the lower troposphere and O3 profiles of the tropopause region, and the usefulness of DIAL backscattering measurements in the study of boundary-layer and tropospheric dynamics is demonstrated. The feasibility of DIAL sensing of power-plant or urban plume SO2, of urban-area (or rural-area column-content) NO2, and of temperature and H2O (simultaneously using a third laser) has been suggested by simulation studies.

Browell, E. V.↗

High-resolution lidar system for measuring the spatial and temporal structure of the mesospheric sodium layer

The design of a high-resolution tunable-dye laser-based lidar system for the study of the mesospheric sodium layer is presented and results of sodium measurements are indicated. The lidar system comprises a tunable flashlamp-pumped dye laser operating at the sodium D2 resonance line at 589.0 nm with a pulse width of 2 microsec FWHM and pulse frequency of 10 Hz and a telescope with a 1.22=m diameter Fresnel lens. Sodium profiles are obtained from the integration of 100 to 250 laser shots, with spatial and temporal resolution enhanced by two-dimensional filtering techniques. Measurements obtained over a 9-hour nighttime period illustrate the highly dynamic nature of the sodium layer, which was observed with a spatial resolution of 2 km and temporal resolution of 30 min. Observations made with a steerable apparatus have confirmed a presunrise enhancement of over 100 percent in sodium column abundance.

Gardner, C. S.↗

Direct solar-pumped iodine laser amplifier

This semiannual progress report covers the period from April 1, 1985 to Sept. 30, 1985 under NASA grant NAS1-441 entitled direct solar pumped iodine laser amplifier. During this period the parametric studies of the iodine laser oscillator pumped by a Vortek simulator was carried out before the amplifier studies. The amplifier studies are postponed to the extended period following completion of the parametric studies. In addition, the kinetic modeling of a solar pumped iodine laser amplifier, and the experimental work for a solar pumped dye laser amplifier are in progress. This report contains three parts: (1) the radiation characteristics of solar simulator and the parametric characteristics of photodissociation iodine laser continuously pumped by a Vortek solar simulator; (2) kinetic modeling of a solar pumped iodine laser amplifier; and (3) the study of the dye laser amplifier pumped by a Tamarack solar simulator.

Han, K. S.↗

Determination of solid mass fraction in partially frozen hydrocarbon fuels

Filtration procedures alone are insufficient to determine the amounts of crystalline solid in a partially frozen hydrocarbon distillate fraction. This is due to the nature of the solidification process by which a large amount of liquid becomes entrapped within an interconnected crystalline structure. A technique has been developed to supplement filtration methods with an independent determination of the amount of liquid in the precipitate thereby revealing the actual value of mass percent crystalline solid, %S. A non-crystallizing dye is injected into the fuel and used as a tracer during the filtration. The relative concentrations of the dye in the filtrate and precipitate fractions is subsequently detected by a spectrophotometric comparison. The filtration apparatus was assembled so that the temperature of the sample is recorded immediately above the filter. Also, a second method of calculation has been established which allows significant reduction in test time while retaining acceptable accuracy of results. Data have been obtained for eight different kerosene range hydrocarbon fuels.

Cotterell, E. M.↗

Direct solar-pumped iodine laser amplifier

During this period the parametric studies of the iodine laser oscillator pumped by a Vortek simulator were carried out before amplifier studies. The amplifier studies are postponed to the extended period after completing the parametric studies. In addition, the kinetic modeling of a solar-pumped iodine laser amplifier, and the experimental work for a solar pumped dye laser amplifier are in progress. This report contains three parts: (1) a 10 W CW iodine laser pumped by a Vortek solar simulator; (2) kinetic modeling to predict the time to lasing threshold, lasing time, and energy output of solar-pumped iodine laser; and (3) the study of the dye laser amplifier pumped by a Tamarack solar simulator.

Han, K. S.↗

An experimental method for measuring droplet impingement efficiency on two- and three-dimensional bodies

An efficient and accurate method is described for extracting water droplet impingement efficiency data from dye impregnated blotter paper samples obtained by employing a dye-tracer technique in wind tunnel spray tests. The method is based on laser reflectance spectroscopy. A brief description of the test method, instrumentation, and data reduction system is also presented. Preliminary test results and analyses are included for a cylinder and a 65(2)015 airfoil.

Papadakis, M.↗

Lidar detection of metallic species at the mesopause level

The measurement alkali species present in the atomic form at the mesopause level has been performed by lidar for more than ten years. Atomic and ionic calcium density profiles are obtained for 3 years by the same technique in the visible range, at 423 nm for atomic calcium, and 393 nm for ionic calcium Ca(+). The experimental set-up and the preliminary results have been presented elsewhere. The 423 nm wavelength is directly obtained by the emission of a dye laser pumped by the third harmonic of a Nd-YAG laser. For the generation of the 393 nm wavelength, frequency mixing was used: the emission at 624 nm of a dye laser pumped by the 2nd harmonic of a Nd-Yag laser is mixed with the fundamental infrared emission (remaining after frequency doubling), in a non-linear KDP crystal, which gives the 393 nm emission. The behavior of the two atomic species, calcium and sodium, which are in the same altitude range are compared. For 45% of the observations, no ionic calcium was detected: the ionic calcium abundance was thus below the detection threshold. Contrasting with the density profiles of the atomic species, sodium and calcium, the ionic calcium profile present important variations on small time scales. The main characteristics of theatomic and ionic calcium behaviors that can be deduced from the measurements made are given.

Granier, C.↗

Simulation of fluid flows during growth of organic crystals in microgravity

Several counter diffusion type crystal growth experiments were conducted in space. Improvements in crystal size and quality are attributed to reduced natural convection in the microgravity environment. One series of experiments called DMOS (Diffusive Mixing of Organic Solutions) was designed and conducted by researchers at the 3M Corporation and flown by NASA on the space shuttle. Since only limited information about the mixing process is available from the space experiments, a series of ground based experiments was conducted to further investigate the fluid dynamics within the DMOS crystal growth cell. Solutions with density differences in the range of 10 to the -7 to 10 to the -4 power g/cc were used to simulate microgravity conditions. The small density differences were obtained by mixing D2O and H2O. Methylene blue dye was used to enhance flow visualization. The extent of mixing was measured photometrically using the 662 nm absorbance peak of the dye. Results indicate that extensive mixing by natural convection can occur even under microgravity conditions. This is qualitatively consistent with results of a simple scaling analysis. Quantitave results are in close agreement with ongoing computational modeling analysis.

Roberts, Gary D.↗

A nondestructive technique for predicting the strength remaining in filament wound composites subjected to low-level impact

A model for predicting the fracture strength of homogeneous materials is proposed. Impacted FWC samples were evaluated using ultrasonic testing and an X-ray dye penetration method. The ability of the model to measure fracture strength was also examined. The relation between attenuation and velocity measurements is studied. It is observed that the X-ray method is not useful for predicting fracture strength because the dye could not penetrate the matrix. It is noted that fracture strength predictions derived from the fracture mechanical model and the ultrasonic measurements correlate well with actual measured fracture strengths.

Madaras, E. I.↗

Simultaneous sampling technique for two spectral sources

A technique is described that uses a bundle of fiber optics to simultaneously sample a dye laser and a spectral lamp. By the use of a real-time display with this technique, the two signals can be superimposed, and the effect of any spectral adjustments can be immediately accessed. In the NASA's CARS system used for combustion diagnostics, the dye laser mixes with a simultaneously pulsed Nd:YAG laser at 532 nm to probe the vibrational levels of nitrogen. An illustration of the oscilloscopic display of the system is presented.

Jarrett, Olin, Jr.↗

Fluid particle motion and Lagrangian velocities for pulsatile flow through a femoral artery branch model

A flow visualization study using selective dye injection and frame by frame analysis of a movie provided qualitative and quantitative data on the motion of marked fluid particles in a 60 degree artery branch model for simulation of physiological femoral artery flow. Physical flow features observed included jetting of the branch flow into the main lumen during the brief reverse flow period, flow separation along the main lumen wall during the near zero flow phase of diastole when the core flow was in the downstream direction, and inference of flow separation conditions along the wall opposite the branch later in systole at higher branch flow ratios. There were many similarities between dye particle motions in pulsatile flow and the comparative steady flow observations.

Cho, Y. I.↗

Filter Enhances Fluorescent-Penetrant-Inspecting Borescope

Slip-on eyepiece for commercial ultraviolet-light borescope reduces both amount of short-wave ultraviolet light that reaches viewer's eye and apparent intensity of unwanted reflections of white light from surfaces undergoing inspection. Fits on stock eyepiece of borescope, which illuminates surface inspected with intense ultraviolet light. Surface, which is treated with fluorescent dye, emits bright-green visible light wherever dye penetrates - in cracks and voids. Eyepiece contains deep-yellow Wratten 15 (G) filter, which attenuates unwanted light strongly but passes yellow-green fluorescence so defects seen clearly.

Molina, Orlando G.↗

Enhancement Of Penetrant-Inspection Images

Proposed computerized video system processes images of fluorescent dyes absorbed in flaws in welds. Video camera, held by operator or by remote manipulator, views weld illuminated by visible white and ultraviolet light. Images of penetrating dye in cracks and voids in weld joint appear on video monitor. Fluorescent features enhanced by software to facilitate identification of true flaws and record important data.

Wilson, Rhonda C.↗

Optical Receiver Based On Luminescent Light Trapping

Experiment demonstrates feasibility of optical-communication receiver based on luminescent light trapping. Light-gathering element plate of transparent material impregnated with laser dye. Light from distant laser transmitter falls on plate and absorbed by dye molecules, which become excited and reradiate. Reradiated light confined within plate by total internal reflection as it propagates toward edge of plate. Light arriving at edge escapes from plate and detected by small, high-speed, high-gain photomultiplier tubes or other photosensitive devices. Simple, inexpensive, and accepts light from almost any angle. Receiver of this configuration supports reception of data at rate of 13 MHz and higher.

Perry, Joseph W.↗

Airborne water vapor DIAL system and measurements of water and aerosol profiles

The Lidar Applications Group at NASA Langley Research Center has developed a differential absorption lidar (DIAL) system for the remote measurement of atmospheric water vapor (H2O) and aerosols from an aircraft. The airborne H2O DIAL system is designed for extended flights to perform mesoscale investigations of H2O and aerosol distributions. This DIAL system utilizes a Nd:YAG-laser-pumped dye laser as the off-line transmitter and a narrowband, tunable Alexandrite laser as the on-line transmitter. The dye laser has an oscillator/amplifier configuration which incorporates a grating and prism in the oscillator cavity to narrow the output linewidth to approximately 15 pm. This linewidth can be maintained over the wavelength range of 725 to 730 nm, and it is sufficiently narrow to satisfy the off-line spectral requirements. In the Alexandrite laser, three intracavity tuning elements combine to produce an output linewidth of 1.1 pm. These spectral devices include a five-plate birefringent tuner, a 1-mm thick solid etalon and a 1-cm air-spaced etalon. A wavelength stability of +/- 0.35 pm is achieved by active feedback control of the two Fabry-Perot etalons using a frequency stabilized He-Ne laser as a wavelength reference. The three tuning elements can be synchronously scanned over a 150 pm range with microprocessor-based scanning electronics. Other aspects of the DIAL system are discussed.

Higdon, Noah S.↗

Phase conjugation by degenerate four wave mixing in disodium fluorescein solution in methanol

Organic dyes are known to show the resonant type of nonlinear optical properties, including phase conjugation. In the present work, disodium fluorescein in methanol is used as an organic nonlinear medium for degenerate four wave mixing at 532 nm to see the intensity dependence of the phase conjugate signal at different concentrations of the solution. It is observed that the maximum reflectivity of the signal occurs in a concentration range of 5 x 10(exp -3)/cu cm to 1.2 x 10(exp -2) g/cu cm. It is also observed that the intensity of the signal drops suddenly to less than half of its maximum outside the concentration range mentioned above. An investigation of the phase conjugate signal intensity by changing the delay time between probe signal and the forward pump is also examined. Briefly discussed is the possibility of population grating in dye liquids as a source of enhancing the third order susceptibility besides the other techniques mentioned in reference. The experiment is done by beam splitting the second harmonic (532 nm) of Nd:YAG laser, Q-switched at 20 pulses/sec (pulse width is approximately 8 and 200 mJ per pulse).

Abdeldayem, Hossin↗

Narrowband lidar technique for sodium temperature and Doppler wind observations of the upper atmosphere

A new two-frequency lidar for measuring mesospheric Na temperature profiles is described that uses a stabilized CW single-mode dye laser oscillator (rms frequency jitter less than 1 MHz) followed by a pulsed dye power amplifier (140 MHz FWHM linewidth) that is pumped by an injection-locked Nd:YAG laser. The laser oscillator is tuned to the two operating freqencies by observing the Doppler-free structure of the Na D2 fluorescence spectrum in a vapor cell. The lidar technique and initial observations of the temperature profile between 82 and 102 km at Ft. Collins, CO are described. Absolute temperature accuracies at the Na layer peak of better than + or - 3 K with a vertical resolution of 1 km and an integration period of approximately 5 min were achieved in this initial experiment. Finally, a multiple frequency technique for the simultaneous measurement of both temperature and Doppler wind profiles is discussed.

Bills, Richard E.↗