Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

Measurements of sensor radiation damage in the ATLAS inner detector using leakage currents

Non-ionizing energy loss causes bulk damage to the silicon sensors of the ATLAS pixel and strip detectors. This damage has important implications for data-taking operations, charged-particle track reconstruction, detector simulations, and physics analysis. This paper presents simulations and measurements of the leakage current in the ATLAS pixel detector and semiconductor tracker as a function of location in the detector and time, using data collected in Run 1 (2010-2012) and Run 2 (2015-2018) of the Large Hadron Collider. The extracted fluence shows a much stronger |z|-dependence in the innermost layers than is seen in simulation. Furthermore, the overall fluence on the second innermost layer is significantly higher than in simulation, with better agreement in layers at higher radii. These measurements are important for validating the simulation models and can be used in part to justify safety factors for future detector designs and interventions.

47 OTHER INSTRUMENTATION↗

A D$_2$O detector for flux normalization of a pion decay-at-rest neutrino source

We report on the technical design and expected performance of a 592 kg heavy-water-Cherenkov detector to measure the absolute neutrino flux from the pion-decay-at-rest neutrino source at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL). The detector will be located roughly 20 m from the SNS target and will measure the neutrino flux with better than 5% statistical uncertainty in 2 years. This heavy-water detector will serve as the first module of a two-module detector system to ultimately measure the neutrino flux to 2–3% at both the First Target Station and the planned Second Target Station of the SNS. This detector will significantly reduce a dominant systematic uncertainty for neutrino cross-section measurements at the SNS, increasing the sensitivity of searches for new physics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Energy resolution of the LZ detector for high-energy electronic recoils

The LUX-ZEPLIN (LZ) detector is a dual-phase liquid xenon time projection chamber (TPC) installed at the Sanford Underground Research Facility (Lead, South Dakota) at a depth of 1478 meters. Although the main objective of LZ is the direct detection of dark matter, its low background environment allows for the search of other rare processes, such as the neutrinoless double beta decay of xenon isotopes 134 Xe and 136 Xe with the respective Q-values of 826 keV and 2458 keV. The sensitivity of the detector to these decays is directly determined by the energy resolution, which, in turn, is degraded by non-uniformities in detector response. In this work, we present a novel method to correct, in the data, the non-uniformity of the light collected by an array of photosensors in a scintillation detector. This method is based on the knowledge of the light response functions of individual photosensors. With these techniques, we report, at a very early phase of the detector operations, a state-of-the-art energy resolution (σ/μ) of (0.67 ± 0.01)% at 2614 keV for the fiducial volume of 5.6 tonnes of liquid xenon.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cryogenic light detectors with thermal signal amplification for 0 νββ search experiments

As a step towards the realization of cryogenic-detector experiments to search for neutrinoless double-beta decay (such as CROSS, BINGO, and CUPID), we investigated a batch of 10 Ge light detectors (LDs) assisted by Neganov-Trofimov-Luke (NTL) signal amplification. Each LD was assembled with a large cubic light-emitting crystal (45 mm side) using the recently developed CROSS mechanical structure. The detector array was operated at milli-Kelvin temperatures in a pulse-tube cryostat at the Canfranc underground laboratory in Spain. We achieved good performance with scintillating bolometers from CROSS, made of Li 2 100 MoO 4 crystals and used as reference detectors of the setup, and with all LDs tested (except for a single device that encountered an electronics issue). No leakage current was observed for 8 LDs with an electrode bias up to 100 V. Operating the LDs at an 80 V electrode bias applied in parallel, we obtained a gain of around 9 in the signal-to-noise ratio of these devices, allowing us to achieve a baseline noise RMS of O(10 eV). Thanks to the strong current polarization of the temperature sensors, the time response of the devices was reduced to around half a millisecond in rise time. The achieved performance of the LDs was extrapolated via simulations of pile-up rejection capability for several configurations of the CUPID detector structure. Despite the sub-optimal noise conditions of the LDs (particularly at high frequencies), we demonstrated that the NTL technology provides a viable solution for background reduction in CUPID.

47 OTHER INSTRUMENTATION↗

Tracking performance of a single-crystal and a polycrystalline diamond pixel-detector

We present a comparative characterization of the performance of a single-crystal and a polycrystalline diamond pixel-detector employing the standard CMS pixel readout chips. Measurements were carried out at the Fermilab Test Beam Facility, FTBF, using protons of momentum 120 GeV/c tracked by a high-resolution pixel telescope. Particular attention was directed to the study of the charge-collection, the charge-sharing among adjacent pixels and the achievable position resolution. The performance of the single-crystal detector was excellent and comparable to the best available silicon pixel-detectors. The measured average detection-efficiency was near unity, ε = 0.99860±0.00006, and the position-resolution for shared hits was about 6 μm. On the other hand, the performance of the polycrystalline detector was hampered by its lower charge collection distance and the readout chip threshold. A new readout chip, capable of operating at much lower threshold (around 1 ke $-$ ), would be required to fully exploit the potential performance of the polycrystalline diamond pixel-detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of muon neutrino induced charged current interactions without charged pions in the final state using a new T2K off-axis near detector WAGASCI-BabyMIND

We report a flux-integrated cross section measurement of muon neutrino interactions on water and hydrocarbon via charged current reactions without charged pions in the final state with the WAGASCI-BabyMIND detector, which was installed in the T2K near detector hall in 2018. The detector is located 1.5° off-axis and is exposed to a more energetic neutrino flux than ND280, another T2K near detector, which is located at a different off-axis position. The total flux-integrated cross section is measured to be 1.26 ± 0.18⁢(stat+syst) × 10 −39 cm 2 /nucleon on CH and 1.44 ± 0.21⁢(stat+syst) × 10 −39 cm 2 /nucleon on H 2 ⁡O. These results are compared to model predictions provided by the neut v5.3.2 and genie v2.8.0 Monte Carlo generators and the measurements are compatible with these models. Differential cross sections in muon momentum and cosine of the muon scattering angle are also reported. This is the first such measurement reported with the WAGASCI-BabyMIND detector and utilizes the 2020 and 2021 datasets.

lepton-hadron interactions↗

Directional response of several geometries for reactor-neutrino detectors

Here we have modeled six abstracted detector designs, with the goal of determining their ability to resolve the direction to an antineutrino source, including two for which we have operational data for validating our computer modeling and analytical processes. We have found that the most promising options, regardless of scale and range, have angular resolutions on the order of a few degrees, which is better than any yet achieved in practice by a factor of at least two. We examine and compare several approaches to detector geometry for their ability not only to detect the inverse beta decay (IBD) reaction, but also to determine the source direction of incident antineutrinos. The information from these detectors provides insight into reactor power and burning profile, which is especially useful in constraining the clandestine production of weapons material. In a live deployment, a nonproliferation detector must be able to isolate the subject reactor, possibly from a field of much-larger power reactors; directional sensitivity can help greatly with this task. We also discuss implications for using such detectors in longer-distance observation of reactors, from a few kilometers to hundreds of kilometers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detection prospects of core-collapse supernovae with supernova-optimized third-generation gravitational-wave detectors

We discuss how to optimize the third-generation gravitational-wave detector to maximize the range to detect core-collapse supernovae. Based on three-dimensional simulations for core-collapse and the corresponding gravitational-wave waveform emitted, the corresponding detection range for these waveforms is limited to within our Galaxy even in the era of third-generation detectors. The corresponding event rate is two per century. We find from the waveforms that to detect core-collapse supernovae with an event rate of one per year, the gravitational-wave detectors need a strain sensitivity of 3 × 10 -27 Hz -1/2 in a frequency range from 100 to 1500 Hz. We also explore detector configurations technologically beyond the scope of third-generation detectors. We find with these improvements, the event rate for gravitational-wave observations from core-collapse supernovae is still low, but is improved to one in twenty years.

79 ASTRONOMY AND ASTROPHYSICS↗

Surface background suppression in liquid argon dark matter detectors using a newly discovered time component of tetraphenyl-butadiene scintillation

Here, decays of radioisotopes on inner detector surfaces can pose a major background concern for the direct detection of dark matter. While these backgrounds are conventionally mitigated with position cuts, these cuts reduce the exposure of the detector by decreasing the sensitive mass, and uncertainty in position determination may make it impossible to adequately remove such events in certain detectors. In this paper, we provide a new technique for substantially reducing these surface backgrounds in liquid argon (LAr) detectors, independent of position cuts. These detectors typically use a coating of tetraphenyl-butadiene (TPB) on the inner surfaces as a wavelength shifter to convert vacuum ultraviolet (VUV) LAr scintillation light to the visible spectrum. We find that TPB scintillation contains a component with a previously unreported exceptionally long lifetime (~ms). We discovered that this component differs significantly in magnitude between alpha, beta, and VUV excitation, which enables the use of pulse shape discrimination to suppress surface backgrounds by more than a factor of 10 3 with negligible loss of dark matter sensitivity. We also discuss how this technique can be extended beyond just LAr experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

In situ X-ray area detector flat-field correction at an operating photon energy without flat illumination

Flat-field calibration of X-ray area detectors is a challenge due to the inability to generate an X-ray flat-field at the selected photon energy the beamline operates at, which has a strong influence on the measurement behavior of the detector. A method is presented in which a simulated flat-field correction is calculated without flat-field measurements. Instead, a series of quick scattering measurements from an amorphous scatterer is used to calculate a flat-field response. The ability to rapidly obtain a flat-field response allows for recalibration of an X-ray detector as needed without significant expenditure of either time or effort. Area detectors on the beamlines used, such as the Pilatus 2M CdTe, PE XRD1621 and Varex XRD 4343CT, were found to have detector responses that drift slightly over timescales of several weeks or after exposure to high photon flux, suggesting the need to more frequently recalibrate with a new flat-field correction map.

47 OTHER INSTRUMENTATION↗

Test of a prototype neutron spectrometer based on diamond detectors in a fast reactor

A prototype of neutron spectrometer based on diamond detectors has been developed. This prototype consists of a {sup 6}Li neutron converter sandwiched between two CVD diamond crystals. The radiation hardness of the diamond crystals makes it suitable for applications in low power research reactors, while a low sensitivity to gamma rays and low leakage current of the detector permit to reach good energy resolution. A fast coincidence between two crystals is used to reject background. The detector was read out using two different electronic chains connected to it by a few meters of cable. The first chain was based on conventional charge-sensitive amplifiers, the other used a custom fast charge amplifier developed for this purpose. The prototype has been tested at various neutron sources and showed its practicability. In particular, the detector was calibrated in a TRIGA thermal reactor (LENA laboratory, University of Pavia) with neutron fluxes of 10{sup 8} n/cm{sup 2}s and at the 3 MeV D-D monochromatic neutron source named FNG (ENEA, Rome) with neutron fluxes of 10{sup 6} n/cm{sup 2}s. The neutron spectrum measurement was performed at the TAPIRO fast research reactor (ENEA, Casaccia) with fluxes of 10{sup 9} n/cm{sup 2}s. The obtained spectra were compared to Monte Carlo simulations, modeling detector response with MCNP and Geant4. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

On Feature, Classifier and Detector Fusers for 235U Signatures Using Gamma Spectral Counts

Three types of information fusion strategies are studied to assess the performance of classifiers for detecting low-level 235 U radiation sources, using features obtained from gamma spectra of NaI detectors. These three strategies are based on using two spectral region features, fusing eight classifiers of diverse designs, and fusing multiple detectors located at different positions around the source. The inner, middle and outer groups of detectors, within a formation of two concentric circles and a spiral of 21 detectors, are identified based on their distance to the source, which is located at the center. This study provides two main qualitative insights into this classification task. First, the fusion of detectors leads to an overall improved classification performance, least in the inner group, most in the outer group, and in between for the middle group. Second, several classifiers and fusers achieve lower training error which does not translate to lower generalization error, indicating their over-fitting to training data.

Rao, Nageswara↗

A Frequency Domain Multiplexing Technique for Multi-Channel Detector Instrumentation

Radiation detection often requires several detectors to be employed at once. Normally, each detector outputs a signal that must be transported, digitized, and stored. One common format for these signals is a finite, aperiodic pulse. Since the detector and data acquisition system are not necessarily physically close, transporting signals from several detectors to a central data acquisition system often requires the use of many cables. The technique presented here allows for the combination and later recovery of a number of analog detector signals using a single cable, by shifting their content to narrow bands in the frequency domain and summing them together into a single channel for transmission. The output is a linear combination of decaying sinusoids, whose peak frequencies and bandwidths in the frequency domain are controlled by inductor, resistor, and capacitor values in the circuit. By separating the outputs by several megahertz, and lowering the bandwidth to about 1 MHz, we can isolate each signal. The timing of the original input can be recovered by taking the inverse Fourier transform of the isolated peak and identifying the start time of the resulting single decaying sinusoid. The energy of the input signal is proportional to the square root of the integral of the corresponding power spectrum peak. We show that energy spectra can be reconstructed with minimal additions to energy resolution. We also show that coincidence timing measurements can be performed with an uncertainty smaller than 2 ns. The result is an N to 1 reduction in cabling, with obvious cost and complexity gains. Since most of the signal content exists only in a band around each peak frequency, noise outside of these bands does not impact the performance.

Belling, Samuel↗

FELIX-Based Readout of the Single-Phase ProtoDUNE Detector

Large liquid argon (LAr) time projection chambers (TPCs) have been adopted for the Deep Underground Neutrino Experiment (DUNE) experiment's far detector, which will be composed of four 17-kton detectors situated 1.5 km underground at the Sanford Underground Research Facility. This represents a large increase in scale compared to existing experiments. Both single- and dual-phase technologies will be validated at CERN, in cryostats capable of accommodating full-size detector modules, and exposed to low-energy charged particle beams. This program, called ProtoDUNE, also allows for extensive tests of data acquisition strategies. The Front-End LInk eXchange (FELIX) readout system was initially developed within the ATLAS collaboration and is based on custom field-programmable gate array (FPGA)-based Peripheral Component Interconnect Express input/output cards, connected through point-to-point links to the detector front end and hosted in commodity servers. FELIX will be used in the single-phase ProtoDUNE setup to read the data coming from 2560 anode wires organized in a single anode plane assembly (APS) structure. With a continuous readout at a sampling rate of 2 MHz, the system must deal with an input rate of 96 Gb/s. An external trigger will preselect time windows of 5 ms with interesting activity expected inside the detector. Event building will occur for triggered events, at a target rate of 25 Hz; the readout system will form fragments from the data samples matching the time window, carry out lossless compression, and forward the data to event building nodes over 10-Gb/s Ethernet. This paper discusses the design and implementation of this readout system as well as the first operational experience.

47 OTHER INSTRUMENTATION↗

Modeling of photocurrent and lag signals in amorphous selenium x-ray detectors

A mathematical model for transient photocurrent and lag signal in x-ray imaging detectors has been developed by considering charge carrier trapping and detrapping in the energy distributed defect states under exponentially distributed carrier generation across the photoconductor. The model for the transient and steady-state carrier distributions and hence the photocurrent has been developed by solving the carrier continuity equation for both holes and electrons. The residual (commonly known as lag signal) current is modeled by solving the trapping rate equations considering the thermal release and trap filling effects. The model is applied to amorphous selenium (a-Se) detectors for both chest radiography and mammography. The authors analyze the dependence of the residual current on various factors, such as x-ray exposure, applied electric field, and temperature. The electron trapping and detrapping mostly determines the residual current in a-Se detectors. The lag signal is more prominent in chest radiographic detector than in mammographic detectors. The model calculations are compared with the published experimental data and show a very good agreement.

42 ENGINEERING↗

Modeling and Analysis of Hybrid Pixel Detector Deficiencies for Scientific Applications

Semiconductor hybrid pixel detectors often consist of a pixellated sensor layer bump bonded to a matching pixelated readout integrated circuit (ROIC). The sensor can range from high resistivity Si to III-V materials, whereas a Si CMOS process is typically used to manufacture the ROIC. Independent, device physics and electronic design automation (EDA) tools are used to determine sensor characteristics and verify functional performance of ROICs respectively with significantly different solvers. Some physics solvers provide the capability of transferring data to the EDA tool. However, single pixel transient simulations are either not feasible due to convergence difficulties or are prohibitively long. A simplified sensor model, which includes a current pulse in parallel with detector equivalent capacitor, is often used; even then, spice type top-level (entire array) simulations range from days to weeks. In order to analyze detector deficiencies for a particular scientific application, accurately defined transient behavioral models of all the functional blocks are required. Furthermore, various simulations, such as transient, noise, Monte Carlo, inter-pixel effects, etc. of the entire array need to be performed within a reasonable time frame without trading off accuracy. The sensor and the analog front-end can be modeling using a real number modeling language, as complex mathematical functions or detailed data can be saved to text files, for further top-level digital simulations. Parasitically aware digital timing is extracted in a standard delay format (sdf) from the pixel digital back-end layout as well as the periphery of the ROIC. For any given input, detector level worst-case and best-case simulations are performed using a Verilog simulation environment to determine the output. Each top-level transient simulation takes no more than 10-15 minutes. The impact of changing key parameters such as sensor Poissonian shot noise, analog front-end bandwidth, jitter due to clock distribution etc. can be accurately analyzed to determine ROIC architectural viability and bottlenecks. Hence the impact of the detector parameters on the scientific application can be studied.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cherenkov photon background for low-noise silicon detectors in space

Future space observatories dedicated to direct imaging and spectroscopy of extra-solar planets will require ultra-low-noise detectors that are sensitive over a broad range of wavelengths. Silicon charge-coupled devices (CCDs), such as EMCCDs, Skipper CCDs, and Multi-Amplifier Sensing CCDs, have demonstrated the ability to detect and measure single photons from ultra-violet to near-infrared wavelengths, making them candidate technologies for this application. In this context, we study a relatively unexplored source of low-energy background coming from Cherenkov radiation produced by energetic charged particles traversing a silicon detector. In the intense radiation environment of space, energetic cosmic rays produce high-energy tracks and more extended halos of low-energy Cherenkov photons, which are detectable with ultra-low-noise detectors. We present a model of this effect that is calibrated to laboratory data, and we use this model to characterize the residual background rate for ultra-low noise silicon detectors in space. We find that the rate of cosmic-ray-induced Cherenkov photon production is comparable to other detector and astrophysical backgrounds that have previously been considered.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Heel effect adaptive flat field correction of digital x-ray detectors

Purpose: Anode heel effect renders large-scale background nonuniformities in digital radiographs. Conventional offset/gain calibration is performed at mono source-to-image distance (SID), and disregards the SID-dependent characteristic of heel effect. It results in a residual nonuniform background in the corrected radiographs when the SID settings for calibration and correction differ. In this work, the authors develop a robust and efficient computational method for digital x-ray detector gain correction adapted to SID-variant heel effect, without resorting to physical filters, phantoms, complicated heel effect models, or multiple-SID calibration and interpolation.Methods: The authors present the Duo-SID projection correction method. In our approach, conventional offset/gain calibrations are performed only twice, at the minimum and maximum SIDs of the system in typical clinical use. A fast iterative separation algorithm is devised to extract the detector gain and basis heel patterns from the min/max SID calibrations. The resultant detector gain is independent of SID, while the basis heel patterns are parameterized by the min- and max-SID. The heel pattern at any SID is obtained from the min-SID basis heel pattern via projection imaging principles. The system gain desired at a specific acquisition SID is then constructed using the projected heel pattern and detector gain map.Results: The method was evaluated for flat field and anatomical phantom image corrections. It demonstrated promising improvements over interpolation and conventional gain calibration/correction methods, lowering their correction errors by approximately 70% and 80%, respectively. The separation algorithm was able to extract the detector gain and heel patterns with less than 2% error, and the Duo-SID corrected images showed perceptually appealing uniform background across the detector.Conclusions: The Duo-SID correction method has substantially improved on conventional offset/gain corrections for digital x-ray imaging in an SID-variant environment. The technique is relatively simple, and can be easily incorporated into multiple-point gain calibration/correction techniques. It offers a potentially valuable tool for preprocessing digital x-ray images to boost image quality of mammography, chest and cardiac radiography, as well as automated computer aided diagnostic radiology.

62 RADIOLOGY AND NUCLEAR MEDICINE↗