Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

Infrared triggered dwell and active cooling thermal control effects on microstructural uniformity in DED

Directed Energy Deposition (DED) offers rapid large scale fabrication, but difficulty in delivering consistent microstructures and properties hinders the use of DED fabricated components in safety or performance critical applications. Variability stems from the complex thermal cycles generated by the toolpath used to print the required geometry. Several practical methods have become established in DED to regulate overheating, such as active cooling of the baseplate structure or the use of an infrared camera to inject interlayer pauses to ensure the top layer of the component cools to a set temperature, which have been shown to affect microstructure. However, no critical assessment has been performed as to how effective these controls are in promoting microstructural uniformity in the context of complex layer timing commonly generated by non-prismatic geometries. Here we show how controls influence the thermal field, phase transformations, and dynamic annealing of a low-temperature transformation steel using infrared imaging and operando neutron diffraction. Counterintuitively, common thermal homogenization process controls can reduce microstructural uniformity because these approaches stabilize peak temperature while overlooking temperatures near the solid-state phase transformation fronts. Instead, the cyclic reheating induces spatially-variant dynamically annealed regions which can be modulated via control parameters. We show that these controls have spatially linked effects centimeters away from the active weld, which implies that microstructure control must co-optimize thermal input across many subsequent layers. In conclusion, our results demonstrate the pressing need for higher order controls that integrate predictive elements of simulation data to stabilize printed properties for future qualification of DED components.

Directed energy deposition↗

A preliminary implementation of metabolic-based pH control to reduce CO 2 usage in outdoor flat-panel photobioreactor cultivation of Nannochloropsis oceanica microalgae

A crucial challenge associated with high-density, commercial-scale, outdoor microalgal cultivation is maintaining pH stability without excessive use of CO 2 buffering. This includes a media-dependent, intracellular metabolic proton imbalance leading to the alkalization or acidification of growth media that results when algae consume, respectively, nitrate or ammonium ions. Feeding these two nitrogen sources can theoretically achieve balanced proton metabolism as well as pH control that is economically more favorable as compared to CO 2 buffering or acid/base addition. To accomplish this, a fed-batch nutrient feeding strategy must be adopted as a component of a model-based pH control system, particularly in the case of ammonium preference. This work represents a preliminary study of the challenges of implementing a nitrogen metabolism based open-loop pH control strategy in the challenging environment of an outdoor photobioreactor at the DOE-ATP 3 testbed facility in Mesa, Arizona during the high solar insolation period of summer 2015. The approach was limited to twice daily fed-batch addition while accounting for ammonium-N preference in a background of nitrate-based algae growth media. Despite these limitations, growth achieved for a photobioreactor operated based on predicted metabolic nitrogen demand (PND) was comparable to ‘CO 2 -on-demand’ (CoD) for pH control. PND reduced CO 2 usage to b10% of CoD control, where the reduced buffering resulted in much greater pH fluctuations due to daily variations in light availability, and a much lower and more consistent media alkalinity (5.73–5.79 mEq/L) as compared to the CoD control (6.51–8.49 mEq/L). While this effort illustrates the utility of feed-forward model-based control, it further illustrates the need for far more sophisticated ‘real time’ monitoring and modeling to accommodate the dynamic outdoor conditions. In conclusion, a need for improved analytics for accurate closure of nitrogen mass balance is also indicated.

09 BIOMASS FUELS↗

Preliminary design of control rods in the single-fluid double-zone thorium molten salt reactor (SD-TMSR)

Recent studies on Molten Salt Reactors (MSRs) showed that the excess reactivity at the beginning of the operation is large for many fueling strategies and must be compensated by a reactivity control system. The current work introduces a reliable safety system based on control rods in addition to the online feed system reactivity control in the Single-fluid Double-zone Thorium-based Molten Salt Reactor (SD-TMSR). Three different initial fissile loadings are considered: 233 U, reactor-grade Pu, and transuranic (TRU) elements as a startup fuel. We applied six different absorbing materials to investigate the main operational and safety parameters in the SD-TMSR: natural B 4 C, enriched B 4 C with 90% 10 B, HfB 2 , HfH 1.62 , Eu 2 O 3 , and Gd 2 O 3 . The present work focuses on control rod design, integral and differential control rod worth, shutdown margin, and shadowing effects at steady-state. We employed the SERPENT-2 Monte-Carlo code to calculate the reactivity worth and analyze the performance of the reactivity control system. We showed that 233 U and reactor-grade Pu startup cores maintain adequate shutdown margin with all considered absorbers. Finally, this report proposes a design of control rod clusters that compensate the excess reactivity of the SD-TMSR loaded with different initial fissile material.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A centralized-based method to determine the local voltage control strategies of distributed generator operation in active distribution networks

The increasing penetration of distributed generators (DGs) exacerbates the risk of voltage violations in active distribution networks (ADNs). The var capacity provided by DG inverters is a potential solution for voltage regulation. The conventional centralized control strategies limited by computation and communication burdens are difficult to meet the requirement of rapid voltage control. However, the local control strategies based on real-time measurements have a fast response to the frequent fluctuations of DG outputs. The performance of these local controllers depends on the tuning of the control parameters. This paper proposes a centralized-based method to determine the local voltage control strategies for DGs. A centralized parameter tuning model of control curves is built, in which and curves of DG inverters are mathematically formulated based on piecewise linearization. The original mixed-integer nonlinear programming (MINLP) model is converted into an effectively solved mixed-integer second-order cone programming (MISOCP) model using convex relaxation. The potential benefits of DG inverters are explored to regulate both reactive and curtailed active power, based on local voltage measurements. Case studies on a modified PG&E 69-node distribution system are carried out to verify the effectiveness of the proposed method. Results show that power losses of ADNs are significantly reduced and voltage profiles are also improved.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Machine learning-based ethylene concentration estimation, real-time optimization and feedback control of an experimental electrochemical reactor

With the increase in electricity supply from clean energy sources, electrochemical reduction of carbon dioxide (CO 2 ) has received increasing attention as an alternative source of carbon-based fuels. As CO 2 reduction is becoming a stronger alternative for the clean production of chemicals, the need to model, optimize and control the electrochemical reduction of the CO 2 process becomes inevitable. However, on one hand, a first-principles model to represent the electrochemical CO 2 reduction has not been fully developed yet because of the complexity of its reaction mechanism, which makes it challenging to define a precise state-space model for the control system. On the other hand, the unavailability of efficient concentration measurement sensors continues to challenge our ability to develop feedback control systems. Gas chromatography (GC) is the most common equipment for monitoring the gas product composition, but it requires a period of time to analyze the sample, which means that GC can provide only delayed measurements during the operation. Moreover, the electrochemical CO 2 reduction process is catalyzed by a fast-deactivating copper catalyst and undergoes a selectivity shift from the product-of-interest at the later stages of experiments, which can pose a challenge for conventional control methods. To this end, machine learning (ML) techniques provide a potential approach to overcome those difficulties due to their demonstrated ability to capture the dynamic behavior of a chemical process from data. Motivated by the above considerations, we propose a machine learning-based modeling methodology that integrates support vector regression and first-principles modeling to capture the dynamic behavior of an experimental electrochemical reactor; this model, together with limited gas chromatography measurements, is employed to predict the evolution of gas-phase ethylene concentration. The model prediction is directly used in a proportional-integral (PI) controller that manipulates the applied potential to regulate the gas-phase ethylene concentration at energy-optimal set-point values computed by a real-time process optimizer (RTO). Specifically, the RTO calculates the operation set-point by solving an optimization problem to maximize the economic benefit of the reactor. Finally, suitable compensation methods are introduced to further account for the experimental uncertainties and handle catalyst deactivation. The proposed modeling, optimization, and control approaches are the first demonstration of active control for a CO 2 electrolyzer and contribute to the automation and scale-up efforts for electrified manufacturing of fuels and chemicals starting from CO 2 .

42 ENGINEERING↗

Reinforcement learning for online adaptation of model predictive controllers: Application to a selective catalytic reduction unit

Here we present a novel application of reinforcement learning (RL) for online dynamic tuning of model predictive controllers (MPC). Applying a state-action-reward-state-action (SARSA) algorithm for temporal difference learning with a control-specific reward function improves the error tracking performance of a standard MPC formulation. The proposed RL approach is also readily adaptable to other MPCs, or entirely different control approaches. Practical details for the implementation of the RL-MPC algorithm are also presented. The proposed algorithm is applied to a case study of controlling nitrogen oxide (NO x ) emissions in an industrial selective catalytic reduction (SCR) unit, a control problem characterized by significant nonlinearity and time delay. Along with an RL-MPC formulation for NOx control, another MPC is proposed to mitigate ammonia slip and decrease ammonia consumption in the SCR. Results showing the efficacy of the RL-MPC for NO x control through learning and implementation on the nonlinear SCR dynamic model are presented.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A signal compensation based cascaded PI control for an industrial heat exchange system

Since the characteristics of the industrial heat exchange system (HES) are drastically affected by variations of the steam pressure, ambient temperature and water quality, it is difficult for the classical cascade PI control system to meet the desirable control objectives. Therefore, in this paper, a deterministic linear model with unmodeled dynamics is used to describe the dynamic characteristics of the HES. It should be noted that the unmodeled dynamics at the previously sampled instant can be calculated using actual measurements and that the tracking error, which includes effects of the rate of changes of unmodeled dynamics on the controlled model, can be accurately determined. An additional compensating signal is obtained with the feedforward control together with a one-step optimal control law. Consequently, the cascade PI control strategy with the signal compensation is established. Furthermore, the simulation and industrial application show that the proposed method can effectively improve the performance of the cascade PI control system, especially when the unmodeled dynamics is subjected to unknown variations.

42 ENGINEERING↗

Dual Rate Adaptive Control for an Industrial Heat Supply Process Using Signal Compensation Approach

The industrial heat supply process (HSP) is a highly nonlinear cascaded process which uses a steam valve opening as its control input, the steam flow-rate as its inner loop output and the supply water temperature as its outer loop output. The relationship between the heat exchange rate and the model parameters, such as steam density, entropy, and fouling correction factor and heat exchange efficiency are unknown and nonlinear. Moreover, these model parameters vary in line with steam pressure, ambient temperature and the residuals caused by the quality variations of the circulation water. When the steam pressure and the ambient temperature are of high values and are subjected to frequent external random disturbances, the supply water temperature and the steam flow-rate would interact with each other and fluctuate a lot. This is also true when the process exhibits unknown characteristic variations of the process dynamics caused by the unexpected changes of the heat exchange residuals. As a result, it is difficult to control the supply water temperature and the rates of changes of steam flow-rate well inside their targeted ranges. In this paper, a novel compensation signal based dual rate adaptive controller is developed by representing the unknown variations of dynamics as unmodeled dynamics. In the proposed controller design, such a compensation signal is constructed and added onto the control signal obtained from the linear deterministic model based feedback control design. Such a compensation signal aims at eliminating the unmodeled dynamics and the rate of changes of the currently sample unmodeled dynamics. A successful industrial application is carried out, where it has been shown that both the supply water temperature and the rate of the changes of the steam flow-rate can be controlled well inside their targeted ranges when the process is subjected to unknown variations of its dynamics.

Adaptive signal approacg↗

Adapting Optimal Velocity Tracking Control to Account for WEC Constraints and Power-Take-Off Efficiencies: Preprint

Wave energy converters (WECs) come in many different forms, from point absorbers, oscillating water columns, to bulge wave devices. This paper focuses on the control of point absorber WECs, which typically have a narrow-banded frequency response and, therefore, control is well placed to improve the energy capture of such WECs. The acausal nature of the control problem means that theoretically optimal control is almost impossible to achieve inpractice; however optimal velocity tracking (OVT) offers a simple and robust approximation to optimal control that can achieve better power capture than passive linear damping methods, albeit with necessarily higher force demands. OVT is a form of impedance matching and the magnitude of the power-take off (PTO) force demand is often not linearly proportional to the WEC velocity, which can lead to PTO force and speed combinations far from the optimalPTO efficiency. The highly non-linear PTO force and speed to efficiency mapping can, without remedial measures, severely diminish the effectiveness of OVT techniques. In this paper, limits to the movement and force of the PTO are demonstrated, allowing OVT to be more easily applied in practice. The effect of PTO efficiency is explored, and a potential solution to the problem of adapting control to account for efficiency is presented. Both aspects of the work presented highlight the requirement for co-design of the WEC, PTO, and controller.

conversion efficiency↗

Multi-mode evaluation of power-maximizing cross-flow turbine controllers

A general method for predicting and evaluating the performance of three candidate cross-flow turbine power-maximizing controllers is presented in this paper using low-order dynamic simulation, scaled laboratory experiments, and full-scale field testing. For each testing mode and candidate controller, performance metrics quantifying energy capture (ability of a controller to maximize power), variation in torque and rotation rate (related to drive train fatigue), and variation in thrust loads (related to structural fatigue) are quantified for two purposes. First, for metrics that could be evaluated across all testing modes, we considered the accuracy with which simulation or laboratory experiments could predict performance at full scale. Second, we explored the utility of these metrics to contrast candidate controller performance. For these turbines and set of candidate controllers, energy capture was found to only differentiate controller performance in simulation, while the other explored metrics were able to predict performance of the full-scale turbine in the field with various degrees of success. Finally, effects of scale between laboratory and full-scale testing are considered, along with recommendations for future improvements to dynamic simulations and controller evaluation.

13 HYDRO ENERGY↗

Methionine Uptake and Required Radiation Dose to Control Glioblastoma

Purpose: The purpose of this study was to retrospectively assess the feasibility of radiation therapy planning for glioblastoma multiforme (GBM) based on the use of methionine (MET) positron emission tomography (PET), and the correlation among MET uptake, radiation dose, and tumor control. Methods and Materials: Twenty-two patients with GBM who underwent MET-PET prior to radiation therapy were enrolled. MET uptake in 30 regions of interest (ROIs) from 22 GBMs, biologically effective doses (BEDs) for the ROIs and their ratios (MET uptake:BED) were compared in terms of whether the ROIs were controlled for >12 months. Results: MET uptake was significantly correlated with tumor control (odds ratio [OR], 10.0; P=.005); however, there was a higher level of correlation between MET uptake:BED ratio and tumor control (OR, 40.0; P<.0001). These data indicated that the required BEDs for controlling the ROIs could be predicted in terms of MET uptake; BED could be calculated as [34.0 × MET uptake] Gy from the optimal threshold of the MET uptake:BED ratio for tumor control. Conclusions: Target delineation based on MET-PET was demonstrated to be feasible for radiation therapy treatment planning. MET-PET could not only provide precise visualization of infiltrating tumor cells but also predict the required radiation doses to control target regions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An analysis of controlled detachment by seeding various impurity species in high performance scenarios on DIII-D and EAST

Experiments at DIII-D and EAST have demonstrated simultaneous high confinement, divertor detachment, and active control of detachment level, all of which are required for ITER. Comparing detachment control via T e and J sat , it appears that is the most straightforward sensor to use for accessing detachment onset, while J sat offers more precise control of degree of detachment. Based on these results, control using nitrogen seeding has so far shown the best ability to follow a target value with the low disruptivity and little to no degradation of performance when an Internal Transport Barrier (ITB) is present, but not all facilities allow its use. Neon seeding also can be paired with feedback control with low impact on core performance as long as there is no disruption, however shots with neon seeding commonly disrupted during these experiments. Argon is effective in EAST, but tends to degrade performance (by ≈ 10%β p ) when detachment is achieved. With ideal conditions and strike point position control, data from a single Langmuir probe are an acceptable input to the control algorithm, but this simple system is easily defeated by strike point displacement comparable to the T e or J sat scale lengths. The presence of an ITB seems to be critical to retaining core performance in detachment in these parameter ranges, as the pedestal pressure tends to decrease as a result of impurity seeding.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Degrees of Rate Control in Interconnected Reaction Networks

Overall reactions in interconnected networks exhibit net, forward, and reverse rates that are governed by both constitutive elementary steps in the pathway of interest and branching elementary steps that lead to alternative products. Accordingly, steps in branching pathways exhibit negative net, forward, and reverse degrees of rate control, as they reduce reaction flux to the desired product. We here contextualize the forward and reverse degrees of rate control in terms of kinetic resistances (inverse of rates) and leverage the additive nature of kinetic resistance to decouple kinetic driving forces contributed by constitutive elementary steps and branching points (nodal species) in interconnected networks. Regardless of the network connectivity, forward and reverse degrees of rate control are shown to converge at equilibrium. Away from equilibrium, we identify two critical features of interconnected networks: stoichiometric regularity─condition where all stoichiometric numbers are unity─and pathway symmetry around nodal species─condition where branching pathways share the same rate constants, stoichiometry, and species concentrations/activities─that result in (i) equal forward, reverse, and consequently net degrees of rate control and (ii) forward and reverse degrees of rate control that exhibit constant offsets, respectively, across all extents of reaction. Furthermore, our discourse further provides a mathematical description for the influence of stoichiometric irregularity and pathway asymmetry on forward and reverse degrees of rate control. Altogether, the presented work details the effects of network (inter)connectivity and stoichiometry on reaction kinetics and, in doing so, establishes general protocols for capturing these effects as additive terms in the formulation of forward and reverse degrees of rate control.

10 SYNTHETIC FUELS↗

Reinforcement Learning‐Based Adaptation of Grid Following Inverter's Internal Controller to Networked Microgrids' Strengths

The varying topological configurations, generator commitments and dispatches, and dynamic load demand lead to changing system's strengths during the operations of networked microgrids. When the system's strengths significantly change, the fixed control gains at large devices may result in unsatisfactory system performance; this necessitates the tuning of the control gains at large devices to adapt to the changing system's strengths. In this paper, observer-based reinforcement learning (RL) is utilised to automatically tune the proportional-integral (PI) gains of phase lock loop (PLL) controller of grid-following (GFL) inverters to adapt to the changing strengths of microgrids and networked microgrids. The RL agent in this framework augments an observer predicting system's strengths, from which the RL control policy will adjust accordingly to tune the PLL controller's gains towards the system's strengths. Also, to enhance the control performance, the recently introduced Barrier function-based RL framework is leveraged for the design of reward function to prevent the high frequency nadir. An operational 26 kV electric distribution system, which is modelled as networked microgrids, is used to illustrate the need and effectiveness of the proposed RL-tuned control.

frequency response↗

Controlling chaos faster

Predictive feedback control is an easy-to-implement method to stabilize unknown unstable periodic orbits in chaotic dynamical systems. Predictive feedback control is severely limited because asymptotic convergence speed decreases with stronger instabilities which in turn are typical for larger target periods, rendering it harder to effectively stabilize periodic orbits of large period. Here, we study stalled chaos control, where the application of control is stalled to make use of the chaotic, uncontrolled dynamics, and introduce an adaptation paradigm to overcome this limitation and speed up convergence. This modified control scheme is not only capable of stabilizing more periodic orbits than the original predictive feedback control but also speeds up convergence for typical chaotic maps, as illustrated in both theory and application. The proposed adaptation scheme provides a way to tune parameters online, yielding a broadly applicable, fast chaos control that converges reliably, even for periodic orbits of large period.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Smart monitoring system based on adaptive current control for superconducting cable test

A smart monitoring system for superconducting cable test is proposed with an adaptive current control of a superconducting transformer secondary. The design, based on Fuzzy Gain Scheduling, allows the controller parameters to adapt continuously, and finely, to the working variations arising from transformer nonlinear dynamics. The control system is integrated in a fully digital control loop, with all the related benefits, i.e., high noise rejection, ease of implementation/modification, and so on. In particular, an accurate model of the system, controlled by a Fuzzy Gain Scheduler of the superconducting transformer, was achieved by an experimental campaign through the working domain at several current ramp rates. The model performance was characterized by simulation, under all the main operating conditions, in order to guide the controller design. Finally, the proposed monitoring system was experimentally validated at European Organization for Nuclear Research (CERN) in comparison to the state-of-the-art control system [P. Arpaia, L. Bottura, G. Montenero, and S. Le Naour, “Performance improvement of a measurement station for superconducting cable test,” Rev. Sci. Instrum.83, 095111 (2012)] of the Facility for the Research on Superconducting Cables, achieving a significant performance improvement: a reduction in the system overshoot by 50%, with a related attenuation of the corresponding dynamic residual error (both absolute and RMS) up to 52%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simple adaptive control system design for a quadrotor with an internal PFC

The paper deals with an adaptive control system design problem for a four rotor helicopter or quadrotor. A simple adaptive control design scheme with a parallel feedforward compensator (PFC) in the internal loop of the considered quadrotor will be proposed based on the backstepping strategy. As is well known, the backstepping control strategy is one of the advanced control strategy for nonlinear systems. However, the control algorithm will become complex if the system has higher order relative degrees. We will show that one can skip some design steps of the backstepping method by introducing a PFC in the inner loop of the considered quadrotor, so that the structure of the obtained controller will be simplified and a high gain based adaptive feedback control system will be designed. The effectiveness of the proposed method will be confirmed through numerical simulations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

On control of continuous dynamical polysystems in discrete times

This paper considers control systems with a finite number of control parameters, i.e. dynamical polysystems. It is assumed that control switchings can occur only at certain discrete times. Statistical methods in number theory are used to investigate the controllability of these systems. Existence of control switching times is established through analysis of Diophantine equations. The values of control switching times are found through suitable numerical methods. Certain assertions on the controllability of the polysystems of the class under consideration are proved. Some examples are considered.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗