Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Constraints”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

Radiation Dose Prescription for Non-Small-Cell Lung Cancer According to Normal Tissue Dose Constraints: An In Silico Clinical Trial

Purpose: Local tumor recurrence remains a major problem in patients with inoperable non-small-cell lung cancer undergoing radiotherapy. We investigated the theoretical gain in the estimated tumor control probability (TCP) using an individualized maximal tolerable dose (MTD) prescription, for both conventional and accelerated fractionation schemes. Methods and Materials: For 64 non-small-cell lung cancer patients, five treatment plans were compared, dependent on the normal tissue dose constraints for the lung and spinal cord. The first two used a classic fractionation (2 Gy/d, 5 d/wk) to a total dose of 60 Gy (QD{sub classic}) or determined by the individualized MTD (QD{sub MTD}). The third scheme assumed a hypofractionated schedule of 2.75-Gy fractions (QD{sub hypofr}). The fourth and fifth assumed hyperfractionation and acceleration (1.8 Gy twice daily, either BID{sub classic} or BID{sub MTD}). The TCPs for the groups of patients were estimated. Results: The mean biologic equivalent dose in 2-Gy fractions for tumor, corrected for accelerated repopulation was significantly greater for the BID{sub MTD} scheme (62.1 Gy) than for any other scheme (QD{sub classic}, 47.5 Gy; QD{sub MTD}, 52.0 Gy; QD{sub hypofr}, 56.9 Gy; and BID{sub classic}, 56.9 Gy; p < 0.001). Although both dose-escalation (QD{sub MTD}) and hypofractionation (QD{sub hypofr}) resulted in an increase in the mean estimated TCP of 5.6% (p < 0.001) and 14.6% (p < 0.001), respectively, compared with QD{sub classic}, the combination of escalation and acceleration (BID{sub MTD}) improved the mean estimated TCP by 26.4% (p < 0.001). Conclusion: The results of this planning study showed a large gain in the estimated TCP using an MTD scheme with 1.8-Gy fractions BID compared with other fractionation schedules. Clinical studies implementing this concept are ongoing.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Modeling of Salivary Production Recovery After Radiotherapy Using Mixed Models: Determination of Optimal Dose Constraint for IMRT Planning and Construction of Convenient Tools to Predict Salivary Function

Purpose: The mathematical relationship between the dose to the parotid glands and salivary gland production needs to be elucidated. This study, which included data from patients included in a French prospective study assessing the benefit of intensity-modulated radiotherapy (RT), sought to elaborate a convenient and original model of salivary recovery. Methods and Materials: Between January 2001 and December 2004, 44 patients were included (35 with oropharyngeal and 9 with nasopharyngeal cancer). Of the 44 patients, 24 were treated with intensity-modulated RT, 17 with three-dimensional conformal RT, and 2 with two-dimensional RT. Stimulated salivary production was collected for {<=}24 months after RT. The data of salivary production, time of follow-up, and dose to parotid gland were modeled using a mixed model. Several models were developed to assess the best-fitting variable for the dose level to the parotid gland. Results: Models developed with the dose to the contralateral parotid fit the data slightly better than those with the dose to both parotids, suggesting that contralateral and ipsilateral parotid glands are not functionally equivalent even with the same dose level to the glands. The best predictive dose-value variable for salivary flow recovery was the volume of the contralateral parotid gland receiving >40 Gy. Conclusion: The results of this study show that the recommendation of a dose constraint for intensity-modulated RT planning should be established at the volume of the contralateral parotid gland receiving >40 Gy rather than the mean dose. For complete salivary production recovery after 24 months, the volume of the contralateral parotid gland receiving >40 Gy should be <33%. Our results permitted us to establish two convenient tools to predict the saliva production recovery function according to the dose received by the contralateral parotid gland.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Novel Dose Constraint to Reduce Xerostomia in Head-and-Neck Cancer Patients Treated With Intensity-Modulated Radiotherapy

Purpose: To investigate the predictors of incidence and duration of xerostomia (XT) based on parotid glands (PG), submandibular glands (SMG), and both glands taken as a whole organ (TG) in head-and-neck cancer patients treated with intensity-modulated radiotherapy. Methods and Materials: A prospective study was initiated in May 2003. Sixty-three head-and-neck patients (44 with nasopharynx cancer) were included in the analysis. Using the dose-volume histogram the PG, SMG, and TG mean doses were calculated. Unstimulated and stimulated salivary flow were measured and XT-related questionnaires were compiled before and at 3, 6, 12, 18, and 24 months after radiotherapy. Salivary gland toxicity was evaluated using the Radiation Therapy Oncology Group scale, and Grade >=3 toxicity was used as the endpoint. The XT incidence was investigated according to descriptive statistics and univariate and multivariate analysis. The Bonferroni method was used for multiple comparison adjustment. Results: After a reduced flow at 3 months after radiotherapy, recovery of salivary flow was observed over time. Primary site and salivary gland mean doses and volumes were identified in univariate analysis as prognostic factors. Multivariate analysis confirmed that TG mean dose (p = 0.00066) and pretreatment stimulated salivary flow (p = 0.00420) are independent factors for predicting XT. Conclusion: The TG mean dose correlates with XT as assessed by Radiation Therapy Oncology Group criteria, salivary output, and XT-related questionnaires. Our results suggest that TG mean dose is a candidate dose constraint for reducing XT, requiring considerably more validation in non-nasopharyngeal cancer patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Association Between Maximal Skin Dose and Breast Brachytherapy Outcome: A Proposal for More Rigorous Dosimetric Constraints

Purpose: Multiple investigations have used the skin distance as a surrogate for the skin dose and have shown that distances <6 mm have been associated with late toxicity after MammoSite brachytherapy. No publications have yet described the relationship between the actual maximal skin dose and the outcome. The present study analyzed the maximal skin dose delivered and the occurrence of late toxicity in a large cohort of patients with prolonged follow-up. Methods: A total of 96 patients treated with breast brachytherapy between 2000 and 2007 for whom complete planning and follow-up data were available were included in the present analysis. The median follow-up was 48 months (range, 24-111). Of the 96 patients, 40 were treated with multicatheter interstitial brachytherapy and 56 with MammoSite. A multivariate statistical analysis was performed to determine the relationship between several dosimetric parameters and patient outcome. Results: The treatment was well tolerated, with 98% of patients experiencing good to excellent cosmesis. Significant late toxicity was uncommon. The maximal dose delivered to the skin was significantly associated with the incidence of any degree of telangiectasia (p = .009) and moderate to severe fibrosis (p = .010). The incidence of late toxicity was significantly increased when the dose to the skin was >4.05 Gy/fraction. Conclusion: The initial skin dose recommendations have been based on safe use and the avoidance of significant toxicity. The results from the present study have suggested that patients might further benefit if more rigorous constraints were applied and if the skin dose were limited to 120% of the prescription dose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose Constraints to Prevent Radiation-Induced Brachial Plexopathy in Patients Treated for Lung Cancer

Purpose: As the recommended radiation dose for non-small-cell lung cancer (NSCLC) increases, meeting dose constraints for critical structures like the brachial plexus becomes increasingly challenging, particularly for tumors in the superior sulcus. In this retrospective analysis, we compared dose-volume histogram information with the incidence of plexopathy to establish the maximum dose tolerated by the brachial plexus. Methods and Materials: We identified 90 patients with NSCLC treated with definitive chemoradiation from March 2007 through September 2010, who had received >55 Gy to the brachial plexus. We used a multiatlas segmentation method combined with deformable image registration to delineate the brachial plexus on the original planning CT scans and scored plexopathy according to Common Terminology Criteria for Adverse Events version 4.03. Results: Median radiation dose to the brachial plexus was 70 Gy (range, 56-87.5 Gy; 1.5-2.5 Gy/fraction). At a median follow-up time of 14.0 months, 14 patients (16%) had brachial plexopathy (8 patients [9%] had Grade 1, and 6 patients [7%] had Grade {>=}2); median time to symptom onset was 6.5 months (range, 1.4-37.4 months). On multivariate analysis, receipt of a median brachial plexus dose of >69 Gy (odds ratio [OR] 10.091; 95% confidence interval [CI], 1.512-67.331; p = 0.005), a maximum dose of >75 Gy to 2 cm{sup 3} of the brachial plexus (OR, 4.909; 95% CI, 0.966-24.952; p = 0.038), and the presence of plexopathy before irradiation (OR, 4.722; 95% CI, 1.267-17.606; p = 0.021) were independent predictors of brachial plexopathy. Conclusions: For lung cancers near the apical region, brachial plexopathy is a major concern for high-dose radiation therapy. We developed a computer-assisted image segmentation method that allows us to rapidly and consistently contour the brachial plexus and establish the dose limits to minimize the risk of brachial plexopathy. Our results could be used as a guideline in future prospective trials with high-dose radiation therapy for unresectable lung cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Novel Method for Predicting Late Genitourinary Toxicity After Prostate Radiation Therapy and the Need for Age-Based Risk-Adapted Dose Constraints

Background: There are no well-established normal tissue sparing dose–volume histogram (DVH) criteria that limit the risk of urinary toxicity from prostate radiation therapy (RT). The aim of this study was to determine which criteria predict late toxicity among various DVH parameters when contouring the entire solid bladder and its contents versus the bladder wall. The area under the histogram curve (AUHC) was also analyzed. Methods and Materials: From 1993 to 2000, 503 men with prostate cancer received 3-dimensional conformal RT (median follow-up time, 71 months). The whole bladder and the bladder wall were contoured in all patients. The primary endpoint was grade ≥2 genitourinary (GU) toxicity occurring ≥3 months after completion of RT. Cox regressions of time to grade ≥2 toxicity were estimated separately for the entire bladder and bladder wall. Concordance probability estimates (CPE) assessed model discriminative ability. Before training the models, an external random test group of 100 men was set aside for testing. Separate analyses were performed based on the mean age (≤ 68 vs >68 years). Results: Age, pretreatment urinary symptoms, mean dose (entire bladder and bladder wall), and AUHC (entire bladder and bladder wall) were significant (P<.05) in multivariable analysis. Overall, bladder wall CPE values were higher than solid bladder values. The AUHC for bladder wall provided the greatest discrimination for late bladder toxicity when compared with alternative DVH points, with CPE values of 0.68 for age ≤68 years and 0.81 for age >68 years. Conclusion: The AUHC method based on bladder wall volumes was superior for predicting late GU toxicity. Age >68 years was associated with late grade ≥2 GU toxicity, which suggests that risk-adapted dose constraints based on age should be explored.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose to the Bladder Neck Is the Most Important Predictor for Acute and Late Toxicity After Low-Dose-Rate Prostate Brachytherapy: Implications for Establishing New Dose Constraints for Treatment Planning

Purpose: To identify an anatomic structure predictive for acute (AUT) and late (LUT) urinary toxicity in patients with prostate cancer treated with low-dose-rate brachytherapy (LDR) with or without external beam radiation therapy (EBRT). Methods and Materials: From July 2002 to January 2013, 927 patients with prostate cancer (median age, 66 years) underwent LDR brachytherapy with Iodine 125 (n=753) or Palladium 103 (n=174) as definitive treatment (n=478) and as a boost (n=449) followed by supplemental EBRT (median dose, 50.4 Gy). Structures contoured on the computed tomographic (CT) scan on day 0 after implantation included prostate, urethra, bladder, and the bladder neck, defined as 5 mm around the urethra between the catheter balloon and the prostatic urethra. AUT and LUT were assessed with the Common Terminology Criteria for Adverse Events, version4. Clinical and dosimetric factors associated with AUT and LUT were analyzed with Cox regression and receiver operating characteristic analysis to calculate area under the receiver operator curve (ROC) (AUC). Results: Grade ≥2 AUT and grade ≥2 LUT occurred in 520 patients (56%) and 154 patients (20%), respectively. No grade 4 toxicities were observed. Bladder neck D2cc retained a significant association with AUT (hazard ratio [HR], 1.03; 95% confidence interval [CI], 1.03-1.04; P<.0001) and LUT (HR, 1.01; 95% CI, 1.00-1.03; P=.014) on multivariable analysis. In a comparison of bladder neck with the standard dosimetric variables by use of ROC analysis (prostate V100 >90%, D90 >100%, V150 >60%, urethra D20 >130%), bladder neck D2cc >50% was shown to have the strongest prognostic power for AUT (AUC, 0.697; P<.0001) and LUT (AUC, 0.620; P<.001). Conclusions: Bladder neck D2cc >50% was the strongest predictor for grade ≥2 AUT and LUT in patients treated with LDR brachytherapy. These data support inclusion of bladder neck constraints into brachytherapy planning to decrease urinary toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Phase 1 Study of Spinal Cord Constraint Relaxation With Single Session Spine Stereotactic Radiosurgery in the Primary Management of Patients With Inoperable, Previously Unirradiated Metastatic Epidural Spinal Cord Compression

We seek to establish the feasibility of using spine stereotactic radiosurgery (SSRS), allowing for spinal cord dose constraint relaxation, as the primary management of metastatic epidural spinal cord compression (MESCC) in inoperable patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optimization-based mesh correction with volume and convexity constraints

Here, we consider the problem of finding a mesh such that 1) it is the closest, with respect to a suitable metric, to a given source mesh having the same connectivity, and 2) the volumes of its cells match a set of prescribed positive values that are not necessarily equal to the cell volumes in the source mesh. Also, this volume correction problem arises in important simulation contexts, such as satisfying a discrete geometric conservation law and solving transport equations by incremental remapping or similar semi-Lagrangian transport schemes. In this paper we formulate volume correction as a constrained optimization problem in which the distance to the source mesh defines an optimization objective, while the prescribed cell volumes, mesh validity and/or cell convexity specify the constraints. We solve this problem numerically using a sequential quadratic programming (SQP) method whose performance scales with the mesh size. To achieve scalable performance we develop a specialized multigrid-based preconditioner for optimality systems that arise in the application of the SQP method to the volume correction problem. Numerical examples illustrate the importance of volume correction, and showcase the accuracy, robustness and scalability of our approach.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

When the dust settles: stable xenon isotope constraints on the formation of nuclear fallout

Nuclear weapons represent one of the most immediate threats of mass destruction. In the event that a procured or developed nuclear weapon is detonated in a populated metropolitan area, timely and accurate nuclear forensic analysis and fallout modeling would be needed to support attribution efforts and hazard assessments. In this work, we demonstrate that fissiogenic xenon isotopes retained in radioactive fallout generated by a nuclear explosion provide unique constraints on (1) the timescale of fallout formation, (2) chemical fractionation that occurs when fission products and nuclear fuel are incorporated into fallout, and (3) the speciation of fission products in the fireball. Our data suggest that, in near surface nuclear tests, the presence of a significant quantity of metal in a device assembly, combined with a short time allowed for mixing with the ambient atmosphere (seconds), may prevent complete oxidation of fission products prior to their incorporation into fallout. Xenon isotopes thus provide a window into the chemical composition of the fireball in the seconds that follow a nuclear explosion, thereby improving our understanding of the physical and thermo-chemical conditions under which fallout forms.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Computer-controlled finishing via dynamically constraint position-velocity-time scheduler

In a Computer Numerical Controlled (CNC) finishing process, the target material removal from an optical surface is guided by the convolution between the influence function of a machine tool and its dwell time at certain points over the surface. To reduce dynamics stressing and increase machining efficiency, the dwell time must be converted to varying velocities, which are the actual inputs to the machine tool controller. Conventionally, the conversion assumed constant acceleration and relied on linear motion interpolation, which caused discontinuities in velocities. This unsmooth motion affects the material removal distribution, and, thus, the accuracy of the finished surface shape. Many modern CNC machines support the smoother, cubic-polynomial interpolated Position-Velocity-Time (PVT) motion mode; however, the conventional scheduler may fail to provide suitable velocities for the PVT. Here in this study answers this challenge by proposing a novel PVT-based velocity scheduler that achieves smooth motion while considering CNC dynamic limits. Firstly, the principle of the PVT is explained, and the PVT-based velocity scheduler is formulated. Secondly, a quadratic programming is used to optimize the velocities by imposing the CNC dynamic constraints and the C 1 continuities (zeroth and first derivatives are continuous) simultaneously. Thirdly, the smoothness and accuracy of the scheduled velocities are studied on different kinds of tool paths via simulation. Finally, a sub-0.3 nm level surface finishing experiment using ion beam figuring is demonstrated to verify the feasibility of the proposed method. The PVT-based scheduler and simulator code is open-sourced.

36 MATERIALS SCIENCE↗

Influences of granular constraints and surface effects on the heterogeneity of elastic, superelastic, and plastic responses of polycrystalline shape memory alloys

Deformation heterogeneities at the microstructural length-scale developed in polycrystalline shape memory alloys (SMAs) during superelastic loading are studied using both experiments and simulations. In situ X-ray diffraction, specifically the far-field high energy diffraction microscopy (ff-HEDM) technique, was used to non-destructively measure the grain-averaged statistics of position, crystal orientation, elastic strain tensor, and volume for hundreds of austenite grains in a superelastically loaded nickel-titanium (NiTi) SMA. These experimental data were also used to create a synthetic microstructure within a finite element model. The development of intragranular stresses were then simulated during tensile loading of the model using anisotropic elasticity. Driving forces for phase transformation and slip were calculated from these stresses. The grain-average responses of individual austenite crystals examined before and after multiple stress-induced transformation events showed that grains in the specimen interior carry more axial stress than the surface grains as the superelastic response "shakes down". Examination of the heterogeneity within individual grains showed that regions near grain boundaries exhibit larger stress variation compared to the grain interiors. As a result, this intragranular heterogeneity is more strongly driven by the constraints of neighboring grains than the initial stress state and orientation of the individual grains.

36 MATERIALS SCIENCE↗

Bond constraint theory studies of chalcogenide phase change memories

Studies of amorphous (a-) semiconductors have been driven by technological advances as well as fundamental theories. Observation of electrical switching, for example, fueled early interest in a-chalcogenides. More recently a-chalcogenide switching has been applied successfully to programmable memory devices as well as DVD technology where the quest for the discovery of better-suited materials continues. Thus, switching grants researchers today with an active arena of technological as well as fundamental study. Bond constraint theory (BCT) and rigidity theory provide a powerful framework for understanding the structure and properties of a-materials. Application of these theories to switching in a-chalcogenides holds the promise of finding the best composition suited for switching applications. Extended X-ray absorption fine structure (EXAFS) spectroscopy is an ideally suited technique to investigate the switching properties of these materials. Films of amorphous Ge{sub 2}Sb{sub 2}Te{sub 4}, Ge{sub 2}Sb{sub 2}Te{sub 5}, and Ge{sub 2}Sb{sub 2}Te{sub 7} exhibit differing bonding structures and bond statistics, which result in different electronic and optical properties. Results of new EXAFS experiments on these three critical compositions in the Ge-Sb-Te system are presented in light of BCT and rigidity theory.

36 MATERIALS SCIENCE↗

Machine learning with knowledge constraints for process optimization of open-air perovskite solar cell manufacturing

Perovskite photovoltaics (PV) have achieved rapid development in the past decade in terms of power conversion efficiency of small-area lab-scale devices; however, successful commercialization still requires further development of low-cost, scalable, and high-throughput manufacturing techniques. One of the critical challenges of developing a new fabrication technique is the high-dimensional parameter space for optimization, but machine learning (ML) can readily be used to accelerate perovskite PV scaling. Herein, we present an ML-guided framework of sequential learning for manufacturing process optimization. We apply our methodology to the Rapid Spray Plasma Processing (RSPP) technique for perovskite thin films in ambient conditions. With a limited experimental budget of screening 100 process conditions, we demonstrated an efficiency improvement to 18.5% as the best-in-our-lab device fabricated by RSPP, and we also experimentally found 10 unique process conditions to produce the top-performing devices of more than 17% efficiency, which is 5 times higher rate of success than the control experiments with pseudo-random Latin hypercube sampling. Our model is enabled by three innovations: (a) flexible knowledge transfer between experimental processes by incorporating data from prior experimental data as a probabilistic constraint; (b) incorporation of both subjective human observations and ML insights when selecting next experiments; (c) adaptive strategy of locating the region of interest using Bayesian optimization first, and then conducting local exploration for high-efficiency devices. Furthermore, in virtual benchmarking, our framework achieves faster improvements with limited experimental budgets than traditional design-of-experiments methods (e.g., one-variable-at-a-time sampling). This framework shows the capability of incorporating researchers’ domain knowledge into the ML-guided optimization loop; therefore, it has the potential to facilitate the wider adoption of ML in scaling to perovskite PV manufacturing.

14 SOLAR ENERGY↗

Experimental Constraints on the Phase Diagram of Titanium Metal

The phase transformations of titanium metal have been studied at temperatures and pressures up to 973 K and 8.7 GPa using synchrotron X-ray diffraction. The equilibrium phase boundary of the a-? transition has a dT/dP slope of 345 K/GPa, and the transition pressure at room temperature is located at 5.7 GPa. The volume change across the a-? transition is ?V=0.197 cm3/mol, and the associated entropy change is ?S=0.57 J/mol K. Except for ?V, our results differ substantially from those of previous studies based on an equilibrium transition pressure of 2.0 GPa at room temperature. The a-?... triple point is estimated to be at 7.5 GPa and 913 K, which is comparable with previous results obtained from differential thermal analysis and resistometric measurements. An update, more accurate phase diagram is established for Ti metal based on the present observations and previous constraints on the a-e and ?-e phase boundaries.

43 PARTICLE ACCELERATORS↗

Image-guided intensity-modulated radiotherapy for prostate cancer: Dose constraints for the anterior rectal wall to minimize rectal toxicity

Rectal adverse events (AEs) are a major concern with definitive radiotherapy (RT) treatment for prostate cancer. The anterior rectal wall is at the greatest risk of injury as it lies closest to the target volume and receives the highest dose of RT. This study evaluated the absolute volume of anterior rectal wall receiving a high dose to identify potential ideal dose constraints that can minimize rectal AEs. A total of 111 consecutive patients with Stage T1c to T3a N0 M0 prostate cancer who underwent image-guided intensity-modulated RT at our institution were included. AEs were graded according to the Common Terminology Criteria for Adverse Events, version 4.0. The volume of anterior rectal wall receiving 5 to 80 Gy in 2.5-Gy increments was determined. Multivariable Cox regression models were used to identify cut points in these volumes that led to an increased risk of early and late rectal AEs. Early AEs occurred in most patients (88%); however, relatively few of them (13%) were grade ≥2. At 5 years, the cumulative incidence of late rectal AEs was 37%, with only 5% being grade ≥2. For almost all RT doses, we identified a threshold of irradiated absolute volume of anterior rectal wall above which there was at least a trend toward a significantly higher rate of AEs. Most strikingly, patients with more than 1.29, 0.73, or 0.45 cm{sup 3} of anterior rectal wall exposed to radiation doses of 67.5, 70, or 72.5 Gy, respectively, had a significantly increased risk of late AEs (relative risks [RR]: 2.18 to 2.72; p ≤ 0.041) and of grade ≥ 2 early AEs (RR: 6.36 to 6.48; p = 0.004). Our study provides evidence that definitive image-guided intensity-modulated radiotherapy (IG-IMRT) for prostate cancer is well tolerated and also identifies dose thresholds for the absolute volume of anterior rectal wall above which patients are at greater risk of early and late complications.

61 RADIATION PROTECTION AND DOSIMETRY↗

Reconstructing cerebrovascular networks under local physiological constraints by integer programming

We introduce a probabilistic approach to vessel network extraction that enforces physiological constraints on the vessel structure. The method accounts for both image evidence and geometric relationships between vessels by solving an integer program, which is shown to yield the maximum a posteriori (MAP) estimate to the probabilistic model. Starting from an over-connected network, it is pruning vessel stumps and spurious connections by evaluating the local geometry and the global connectivity of the graph. We utilize a high-resolution micro computed tomography (µCT) dataset of a cerebrovascular corrosion cast to obtain a reference network and learn the prior distributions of our probabilistic model. As a result, we perform experiments on micro magnetic resonance angiography (µMRA) images of mouse brains and discuss properties of the networks obtained under different tracking and pruning approaches.

59 BASIC BIOLOGICAL SCIENCES↗

Evaluation of Neutron-induced Cross Sections and their Related Covariances with Physical Constraints

Nuclear data, along with numerical methods and the associated calculation schemes, continue to play a key role in reactor design, reactor core operating parameters calculations, fuel cycle management and criticality safety calculations. Due to the intensive use of Monte-Carlo calculations reducing numerical biases, the final accuracy of neutronic calculations increasingly depends on the quality of nuclear data used. This paper gives a broad picture of all ingredients treated by nuclear data evaluators during their analyses. After giving an introduction to nuclear data evaluation, we present implications of using the Bayesian inference to obtain evaluated cross sections and related uncertainties. In particular, a focus is made on systematic uncertainties appearing in the analysis of differential measurements as well as advantages and drawbacks one may encounter by analyzing integral experiments. The evaluation work is in general done independently in the resonance and in the continuum energy ranges giving rise to inconsistencies in evaluated files. For future evaluations on the whole energy range, we call attention to two innovative methods used to analyze several nuclear reaction models and impose constraints. Finally, we discuss suggestions for possible improvements in the evaluation process to master the quantification of uncertainties. These are associated with experiments (microscopic and integral), nuclear reaction theories and the Bayesian inference.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗