Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Automatic”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

Fully automatic multi-organ segmentation for head and neck cancer radiotherapy using shape representation model constrained fully convolutional neural networks

Experiments on clinical datasets of H&N patients demonstrated the effectiveness of the proposed deep neural network segmentation method for multi-organ segmentation on volumetric CT scans. Additionally, the accuracy and robustness of the segmentation were further increased by incorporating shape priors using SMR. The proposed method showed competitive performance and took shorter time to segment multiple organs in comparison to state of the art methods.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Dataset of CFD Simulated Industrial Furnace Images for Conditional Automatic Generation with GANs

The steel industry is constantly looking for ways to automate processes and improve efficiency. A standard practice in industry is to simulate how complex systems will operate before they are actually used. Some complex systems, including steel industry processes such as blast furnaces, require complex physics-based simulations utilizing computational fluid dynamics (CFD). These CFD physics-based simulations are very accurate but can take significant time and computational resources to process, resulting in challenges for the implementation of the models in real-world operational environments. In recent years, deep learning (DL) has been considered as a substitute for these CFD models. DL models can be trained on validated CFD simulation data and then used for industrial process inference. Previous DL-based solutions have made great contributions for industrial automation but are currently missing the additional visualization component that CFD simulations also provide. In this paper, we propose a dataset for simple DL generative approaches that can help to address this issue. The dataset and methodology under development to approach this prediction are discussed in this work.

Calix, Ricardo↗

Semi-automatic Methods for Airway and Adjacent Vessel Measurement in Bronchiectasis Patterns in Lung HRCT Images of Cystic Fibrosis Patients

Airway and vessel characterization of bronchiectasis patterns in lung high-resolution computed tomography (HRCT) images of cystic fibrosis (CF) patients is very important to compute the score of disease severity. We propose a hybrid and evolutionary optimized threshold and model-based method for characterization of airway and vessel in lung HRCT images of CF patients. First, the initial model of airway and vessel is obtained using the enhanced threshold-based method. Then, the model is fitted to the actual image by optimizing its parameters using particle swarm optimization (PSO) evolutionary algorithm. The experimental results demonstrated the outperformance of the proposed method over its counterpart in R-squared, mean and variance of error, and run time. Moreover, the proposed method outperformed its counterpart for airway inner diameter/vessel diameter (AID/VD) and airway wall thickness/vessel diameter (AWT/VD) biomarkers in R-squared and slope of regression analysis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Automatic Modeling of VVER-1000 Power Maneuvers

A special version of the IR code is described. The purpose of this code is to generate recommendations for the reactor operator when operating in a maneuvering regime, automate boron regulation, and study the maneuvering characteristics of VVER-1000 fuel loads. The results of modeling of operation in a daily load schedule are presented for the example of a stationary run of VVER-TOI. The impact of variation of the parameters of power maneuvers (run, operating time a reduced power, loading rate) on the boron regulation parameters is analyzed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Experience in the Implementation of an Automatic System for Stabilizing the Mode of a Power District in Terms of Voltage and Reactive Power

Questions regarding the creation of a power district two-level control system for voltage and reactive power overflows are examined. Objectives and tasks are designated for the control system, and resolution of this makes it possible to increase the power efficiency of the power grid company. A methodology for controlling equipment at the substation (SS) level is briefly described, as well as expansion and test results on a dynamic model of the power grid.

42 ENGINEERING↗

The effect of CT-based attenuation correction on the automatic perfusion score of myocardial perfusion imaging using a dedicated cardiac solid-state CZT SPECT/CT

Background: Data regarding cardiac cadmium-zinc-telluride (CZT)-specific augmented databases and their impact on CT-based attenuation correction (AC) perfusion scores in myocardial perfusion imaging (MPI) were obtained on a multiple-pinhole CZT SPECT/CT. Methods and Results: Summed stress (SSS) and rest scores (SRS) were measured using automated software in three independent patient groups: group 1 (n = 80) underwent MPI on both CZT and conventional sodium iodide (NaI) devices, group 2 (n = 80) with low coronary artery disease likelihood and normal MPI provided reference CZT databases; and group 3 (n = 152) served to compare AC and non-AC (NAC) scores on CZT. Group 1 CZT and NaI scores gave a significant 1:1 linear correlation for CZT scores referenced to the custom database vs NaI scores referenced to the default database, but these were not concordant when CZT scores were referenced to the default database. AC significantly decreased average SSS and SRS in men vs NAC, 4.29 ± 6.30 vs 5.37 ± 7.26 (P < 0.001) and 2.37 ± 4.72 vs 3.13 ± 5.85 (P < 0.001), but not in women, 2.28 ± 3.42 vs 2.28 ± 3.08 (p NS) and 0.46 ± 1.51 vs 0.61 ± 1.86, (p NS), respectively. Conclusions: Specifically designed databases for solid-state CZT cardiac SPECT provide accurate quantitation of perfusion scores concordant with those previously validated for conventional SPECT. AC and NAC CZT scores differed significantly, especially in men.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Automatic Analyte-Ion Recognition and Background Removal for Ambient Mass-Spectrometric Data Based on Cross-Correlation

Ambient mass spectrometry is a powerful approach for rapid, high-throughput, and direct sample analysis. Due to the open-air desorption and ionization processes, random fluctuations of ambient conditions can lead to large variances in mass-spectral signals over time. The mass-spectral data also can be further complicated due to multiple analytes present in the sample, background-ion signals stemming from the desorption/ionization source itself, and other laboratory-specific conditions (e.g., ambient laboratory air, nearby hardware). Thus, background removal and analyte-ion recognition can be quite difficult, particularly in non-targeted analyses. Here, we demonstrate the use of a cross-correlation-based approach to exploit chemical information encoded in the time domain to group/categorize mass-spectral peaks from a single analysis dataset. Ions that originate from ambient (or other) background species were readily flagged and removed from spectra; the result was a decrease in mass-spectral complexity by over 70% due to the removal of these background ions. Meanwhile, analyte ions were differentiated and categorized based on their time-domain profiles. With sufficient mass resolving-power and mass-spectral acquisition rate, isolated mass spectra containing ions from the same species in a sample could be extracted, leading to a reduction in mass-spectral complexity by more than 98% in some cases. The cross-correlation approach was tested with different ionization sources as well as reproducible and irreproducible sample introduction. Software built in-house enabled fully automated data processing, which can be performed within a few seconds. Ultimately, this approach provides an additional dimension of analyte separation in ambient mass-spectrometric analyses with information that is already recorded throughout the analysis. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Automatic Determination of the Weak-Beam Condition in Dark Field X-ray Microscopy

Mechanical properties in crystals are strongly correlated to the arrangement of 1D line defects, termed dislocations. Recently, Dark field X-ray Microscopy (DFXM) has emerged as a new tool to image and interpret dislocations within crystals using multidimensional scans. However, the methods required to reconstruct meaningful dislocation information from high-dimensional DFXM scans are still nascent and require significant manual oversight (i.e. supervision). In this work, we present a new relatively unsupervised method that extracts dislocation-specific information (features) from a 3D dataset (x, y, Φ) using Gram-Schmidt orthogonalization to represent the large dataset as an array of 3-component feature vectors for each position, corresponding to the weak-beam conditions and the strong-beam condition. Finally, this method offers key opportunities to significantly reduce dataset size while preserving only the crystallographic information that is important for data reconstruction.

36 MATERIALS SCIENCE↗

SymbolFit: Automatic Parametric Modeling with Symbolic Regression

We introduce SymbolFit (API: https://github.com/hftsoi/symbolfit), a framework that automates parametric modeling by using symbolic regression to perform a machine-search for functions that fit the data while simultaneously providing uncertainty estimates in a single run. Traditionally, constructing a parametric model to accurately describe binned data has been a manual and iterative process, requiring an adequate functional form to be determined before the fit can be performed. The main challenge arises when the appropriate functional forms cannot be derived from first principles, especially when there is no underlying true closed-form function for the distribution. In this work, we develop a framework that automates and streamlines the process by utilizing symbolic regression, a machine learning technique that explores a vast space of candidate functions without requiring a predefined functional form because the functional form itself is treated as a trainable parameter, making the process far more efficient and effortless than traditional regression methods. We demonstrate the framework in high-energy physics experiments at the CERN Large Hadron Collider (LHC) using five real proton-proton collision datasets from new physics searches, including background modeling in resonance searches for high-mass dijet, trijet, paired-dijet, diphoton, and dimuon events. We show that our framework can flexibly and efficiently generate a wide range of candidate functions that fit a nontrivial distribution well using a simple fit configuration that varies only by random seed, and that the same fit configuration, which defines a vast function space, can also be applied to distributions of different shapes, whereas achieving a comparable result with traditional methods would have required extensive manual effort.

Tsoi, Ho Fung [Univ. of Pennsylvania, Philadelphia↗