Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ARTIFACTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

Towards improved local hybrid functionals by calibration of exchange-energy densities

A new approach for the calibration of (semi-)local and exact exchange-energy densities in the context of local hybrid functionals is reported. The calibration functions are derived from only the electron density and its spatial derivatives, avoiding spatial derivatives of the exact-exchange energy density or other computationally unfavorable contributions. The calibration functions fulfill the seven more important out of nine known exact constraints. It is shown that calibration improves substantially the definition of a non-dynamical correlation energy term for generalized gradient approximation (GGA)-based local hybrids. Moreover, gauge artifacts in the potential-energy curves of noble-gas dimers may be corrected by calibration. The developed calibration functions are then evaluated for a large range of energy-related properties (atomization energies, reaction barriers, ionization potentials, electron affinities, and total atomic energies) of three sets of local hybrids, using a simple one-parameter local-mixing. The functionals are based on (a) local spin-density approximation (LSDA) or (b) Perdew-Burke-Ernzerhof (PBE) exchange and correlation, and on (c) Becke-88 (B88) exchange and Lee-Yang-Parr (LYP) correlation. While the uncalibrated GGA-based functionals usually provide very poor thermochemical data, calibration allows a dramatic improvement, accompanied by only a small deterioration of reaction barriers. In particular, an optimized BLYP-based local-hybrid functional has been found that is a substantial improvement over the underlying global hybrids, as well as over previously reported LSDA-based local hybrids. It is expected that the present calibration approach will pave the way towards new generations of more accurate hyper-GGA functionals based on a local mixing of exchange-energy densities.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A six-channel pediatric coil array for detection of children spinal pathologies by MRI at 1.5 Tesla

Nowadays, magnetic resonance (MR) in Mexico has become a standard technique for clinical imaging. Although most of the times the MR systems contain only coils oriented for adults. Radiologists use these coils for children studies due to the non-availability of pediatric coils. Image quality is decreased due to the low signal to noise ratio delivered to the system. The development of RF coils is always focused towards increasing SNR and optimizing the RF penetration into the sample. Moreover, spinal pathologies in children, which are an important topic in pediatric care, cover congenital and neuromuscular disorders that occur in childhood. In this work, the design of a dedicated six-channel coil for detection of spinal pathologies at 1.5 Tesla is addressed. Numerical electromagnetic simulations were performed in order to evaluate their magnetic field performance at (63.6 MHz) 1.5 Tesla. The magnetic field uniformity as well as the RF penetration depth of the coil configurations was evaluated in order to find the best/optimized coil array configuration. The coil is comprised of three rows, one with 4 coil elements and two with only one coil element. Phantom and in vivo images were acquired with the six-channel pediatric coil array. The phantom images agree with the simulated data. In vivo images acquired with the 6-channel pediatric coil array have shown very good penetration depth and homogeneity, which allow better image quality throughout the whole FOV. In addition, the parallel imaging capabilities of the array allow the acceleration of the experiments avoiding possible motion artifacts.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The use of wavelet filters for reducing noise in posterior fossa Computed Tomography images

Wavelet transform based de-noising like wavelet shrinkage, gives the good results in CT. This procedure affects very little the spatial resolution. Some applications are reconstruction methods, while others are a posteriori de-noising methods. De-noising after reconstruction is very difficult because the noise is non-stationary and has unknown distribution. Therefore, methods which work on the sinogram-space don’t have this problem, because they always work over a known noise distribution at this point. On the other hand, the posterior fossa in a head CT is a very complex region for physicians, because it is commonly affected by artifacts and noise which are not eliminated during the reconstruction procedure. This can leads to some false positive evaluations. The purpose of our present work is to compare different wavelet shrinkage de-noising filters to reduce noise, particularly in images of the posterior fossa within CT scans in the sinogram-space. This work describes an experimental search for the best wavelets, to reduce Poisson noise in Computed Tomography (CT) scans. Results showed that de-noising with wavelet filters improved the quality of posterior fossa region in terms of an increased CNR, without noticeable structural distortions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Monte Carlo simulation of an x-ray luminescence optical tomography scanner prototype

In this work we report the calculation of the deposited energy distribution produced by an x-ray luminescence optical tomography (XLOT) system in a phantom containing different concentrations of Gd{sub 2}O{sub 2}S:Eu nanoparticles. The calculations were performed via Monte Carlo simulation considering spectra from a W target x-ray tube operating between 30 and 90 kVp, with 1.0 mm Al added filtration. CT and XLOT tomographic images were reconstructed from the same data. The results show that XLOT has better detectability than CT alone, that the dose scales linearly with kVp for a fixed concentration of Gd{sub 2}O{sub 2}S:Eu and air-kerma rate, the scattered radiation contribution to the total dose and signal is about 20% and that the dose ratio for a 3 mm diameter insert containing 10 mg/ml Gd{sub 2}O{sub 2}S embedded in a 30 mm diameter water phantom is 6:1. This ratio drops to less than 2:1 for a 1 mg/ml concentration. Finally we show that the method of conjugate images can be used to correct for artifacts due to attenuation effects in XLOT images.

60 APPLIED LIFE SCIENCES↗

Reducing acquisition times in multidimensional NMR with a time-optimized Fourier encoding algorithm

Speeding up the acquisition of multidimensional nuclear magnetic resonance (NMR) spectra is an important topic in contemporary NMR, with central roles in high-throughput investigations and analyses of marginally stable samples. A variety of fast NMR techniques have been developed, including methods based on non-uniform sampling and Hadamard encoding, that overcome the long sampling times inherent to schemes based on fast-Fourier-transform (FFT) methods. Here, we explore the potential of an alternative fast acquisition method that leverages a priori knowledge, to tailor polychromatic pulses and customized time delays for an efficient Fourier encoding of the indirect domain of an NMR experiment. By porting the encoding of the indirect-domain to the excitation process, this strategy avoids potential artifacts associated with non-uniform sampling schemes and uses a minimum number of scans equal to the number of resonances present in the indirect dimension. An added convenience is afforded by the fact that a usual 2D FFT can be used to process the generated data. Acquisitions of 2D heteronuclear correlation NMR spectra on quinine and on the anti-inflammatory drug isobutyl propionic phenolic acid illustrate the new method's performance. This method can be readily automated to deal with complex samples such as those occurring in metabolomics, in in-cell as well as in in vivo NMR applications, where speed and temporal stability are often primary concerns.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of a microwave capacitive method for the spectroscopy of the complex permittivity

We describe a vector network analyzer-based method to study the electromagnetic properties of nanoscale dielectrics at microwave frequencies (1 MHz–40 GHz). The complex permittivity spectrum of a given dielectric can be determined by placing it in a capacitor accessed on its both electrodes by coplanar waveguides. However, inherent propagation delays along the signal paths together with frequency-dependent effective surface of the capacitor at microwave frequencies can lead to significant distortion in the measured permittivity, which in turn can give rise to artificial frequency variations of the complex permittivity. We detail a fully analytical rigorous correction sequence with neither recourse to extrinsic loss mechanisms nor to arbitrary parasitic signal paths. We illustrate our method on 3 emblematic dielectrics: ferroelectric morphotropic lead zirconate titanate, its paraelectric pyrochlore counterpart, and strontium titanate. Permittivity spectra taken at various points along the hysteresis loop help shedding light onto the nature of the different dielectric energy loss mechanisms. Thanks to the analytical character of our method, we can discuss routes to extend it to higher frequencies and we can identify unambiguously the sources of potential artifacts.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Two-dimensional NMR measurement and point dipole model prediction of paramagnetic shift tensors in solids

A new two-dimensional Nuclear Magnetic Resonance (NMR) experiment to separate and correlate the first-order quadrupolar and chemical/paramagnetic shift interactions is described. This experiment, which we call the shifting-d echo experiment, allows a more precise determination of tensor principal components values and their relative orientation. It is designed using the recently introduced symmetry pathway concept. A comparison of the shifting-d experiment with earlier proposed methods is presented and experimentally illustrated in the case of {sup 2}H (I = 1) paramagnetic shift and quadrupolar tensors of CuCl{sub 2}⋅2D{sub 2}O. The benefits of the shifting-d echo experiment over other methods are a factor of two improvement in sensitivity and the suppression of major artifacts. From the 2D lineshape analysis of the shifting-d spectrum, the {sup 2}H quadrupolar coupling parameters are 〈C{sub q}〉 = 118.1 kHz and 〈η{sub q}〉 = 0.88, and the {sup 2}H paramagnetic shift tensor anisotropy parameters are 〈ζ{sub P}〉 = − 152.5 ppm and 〈η{sub P}〉 = 0.91. The orientation of the quadrupolar coupling principal axis system (PAS) relative to the paramagnetic shift anisotropy principal axis system is given by (α,β,γ)=((π)/2 ,(π)/2 ,0). Using a simple ligand hopping model, the tensor parameters in the absence of exchange are estimated. On the basis of this analysis, the instantaneous principal components and orientation of the quadrupolar coupling are found to be in excellent agreement with previous measurements. A new point dipole model for predicting the paramagnetic shift tensor is proposed yielding significantly better agreement than previously used models. In the new model, the dipoles are displaced from nuclei at positions associated with high electron density in the singly occupied molecular orbital predicted from ligand field theory.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Absorption and emission of silicon nanocrystals embedded in SiC: Eliminating Fabry-Pérot interference

Silicon nanocrystals embedded in SiC are studied by spectrophotometry and photoluminescence (PL) spectroscopy. Absorptivities are found to be affected by residual Fabry-Pérot interference arising from measurements of reflection and transmission at locations of different film thickness. Multiple computational and experimental methods to avoid these errors in thin film measurements, in general, are discussed. Corrected absorptivity depends on the quantity of Si embedded in the SiC but is independent of the Si crystallinity, indicating a relaxation of the k-conservation criterion for optical transitions in the nanocrystals. Tauc gaps of 1.8–2.0 and 2.12 eV are determined for Si nanoclusters and SiC, respectively. PL spectra exhibit a red-shift of ∼100 nm per nm nominal Si nanocluster diameter, which is in agreement with quantum confinement but revealed to be an artifact entirely due to Fabry-Pérot interference. Several simple experimental methods to diagnose or avoid interference in PL measurements are developed that are applicable to all thin films. Corrected PL is rather weak and invariant with passivation, indicating that non-paramagnetic defects are responsible for rapid non-radiative recombination. They are also responsible for the broad, sub-gap PL of the SiC, and can wholly account for the form of the PL of samples with Si nanoclusters. The PL intensity of samples with Si nanoclusters, however, can only be explained with an increased density of luminescent defects in the SiC due to Si nanoclusters, efficient tunneling of photogenerated carriers from Si nanoclusters to SiC defects, or with emission from a-Si nanoclusters. Films prepared on Si exhibit much weaker PL than the same films prepared on quartz substrates.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Femtosecond stimulated Raman spectroscopy by six-wave mixing

Femtosecond Stimulated Raman Spectroscopy (FSRS) is motivated by the knowledge of the molecular geometry changes that accompany sub-picosecond chemical reactions. The detection of vibrational resonances throughout the entire fingerprint region of the spectrum with sub-100-fs delay precision is fairly straightforward to accomplish with the FSRS technique. Despite its utility, FSRS must contend with substantial technical challenges that stem from a large background of residual laser light and lower-order nonlinearities when all laser pulses are electronically resonant with the equilibrium system. In this work, a geometry based on five incident laser beams is used to eliminate much of this undesired background in experiments conducted on metmyoglobin. Compared to a three-beam FSRS geometry with all electronically resonant laser pulses, the five-beam approach described here offers major improvements in the data acquisition rate, sensitivity, and background suppression. The susceptibility of the five-beam geometry to experimental artifacts is investigated using control experiments and model calculations. Of particular concern are undesired cascades of third-order nonlinearities, which are known to challenge FSRS measurements carried out on electronically off-resonant systems. It is generally understood that “forbidden” steps in the desired nonlinear optical processes are the origin of the problems encountered under off-resonant conditions. In contrast, the present experiments are carried out under electronically resonant conditions, where such unfortunate selection rules do not apply. Nonetheless, control experiments based on spectroscopic line shapes, signal phases, and sample concentrations are conducted to rule out significant contributions from cascades of third-order processes. Theoretical calculations are further used to estimate the relative intensities of the direct and cascaded responses. Overall, the control experiments and model calculations presented in this work suggest promise for multidimensional resonance Raman investigations of heme proteins.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of general X-ray scattering model

X-ray scattering is a complex process made difficult to describe due to the effects of a complex energy spectrum interacting with a wide range of material types in complex geometry. The scattering is further complicated by the volume of material illuminated and the experimental configuration of the data acquisition. The importance of accounting for the key physics in scattering modeling is critical to the viability of the model. For example, scattering in the detector and the speed of the detector, as measured by the absorbed dose needed to produce a signal, are important in capturing undercut effects. Another example is the noise properties of the detectors are dependent on photon energy. We report on a semi-empirical treatment of x-ray scattering that includes a full energy treatment for a wide range of material types. We also include complex geometry effects that the part shape introduces. The treatment is based on experimental measurements using an energy dispersive germanium detector over energies from treatment is showing good results with experimental measurements of the scattering component agreeing with the model results to the 10% level over the range of x-ray energies and materials typical in industrial applications. Computation times for this model are in the 20 keV to 320 keV. Detector stripping routines for detector artifacts were developed. The computation time is in the range of a few minutes on a typical PC.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Multiple attenuation to reflection seismic data using Radon filter and Wave Equation Multiple Rejection (WEMR) method

Separation between signal and noise, incoherent or coherent, is important in seismic data processing. Although we have processed the seismic data, the coherent noise is still mixing with the primary signal. Multiple reflections are a kind of coherent noise. In this research, we processed seismic data to attenuate multiple reflections in the both synthetic and real seismic data of Mentawai. There are several methods to attenuate multiple reflection, one of them is Radon filter method that discriminates between primary reflection and multiple reflection in the τ-p domain based on move out difference between primary reflection and multiple reflection. However, in case where the move out difference is too small, the Radon filter method is not enough to attenuate the multiple reflections. The Radon filter also produces the artifacts on the gathers data. Except the Radon filter method, we also use the Wave Equation Multiple Elimination (WEMR) method to attenuate the long period multiple reflection. The WEMR method can attenuate the long period multiple reflection based on wave equation inversion. Refer to the inversion of wave equation and the magnitude of the seismic wave amplitude that observed on the free surface, we get the water bottom reflectivity which is used to eliminate the multiple reflections. The WEMR method does not depend on the move out difference to attenuate the long period multiple reflection. Therefore, the WEMR method can be applied to the seismic data which has small move out difference as the Mentawai seismic data. The small move out difference on the Mentawai seismic data is caused by the restrictiveness of far offset, which is only 705 meter. We compared the real free multiple stacking data after processing with Radon filter and WEMR process. The conclusion is the WEMR method can more attenuate the long period multiple reflection than the Radon filter method on the real (Mentawai) seismic data.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Interpretation of thermal conductivity in LaFeAsO at low temperatures

Thermal conductivity κ(T) of LaFeAsO is theoretically investigated below the spin density wave (SDW) anomaly. The lattice contribution to the thermal conductivity (κ{sub ph}) is discussed within the Debye-type relaxation rate approximation in terms of the acoustic phonon frequency and relaxation time below 150 K. The theory is formulated when heat transfer is limited by the scattering of phonons from defects, grain boundaries, charge carriers, and phonons. The lattice thermal conductivity dominates in LaFeAsO and is an artifact of strong phonon-impurity and -phonon scattering mechanism. Our result indicates that the maximum contribution comes from phonon scatters and various thermal scattering mechanisms provide a reasonable explanation for maximum appeared in κ (T)

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

CCQE, 2p2h excitations and ν—energy reconstruction

We analyze the MiniBooNE muon neutrino CCQE-like dσ/dT{sub μ} d cos θ{sub μ} data using a theoretical model that, among other nuclear effects, includes RPA correlations and 2p2h (multinucleon) mechanisms. These corrections turn out to be essential for the description of the data. We find that MiniBooNE CCQE-like data are fully compatible with former determinations of the nucleon axial mass M{sub A} ∼ 1.05 GeV. This is in sharp contrast with several previous analysis where anomalously large values of M{sub A} ∼ 1.4 GeV have been suggested. We also show that because of the the multinucleon mechanism effects, the algorithm used to reconstruct the neutrino energy is not adequate when dealing with quasielastic-like events. Finally, we analyze the MiniBooNE unfolded cross section, and show that it exhibits an excess (deficit) of low (high) energy neutrinos, which is an artifact of the unfolding process that ignores 2p2h mechanisms.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Beam tracking approach for single–shot retrieval of absorption, refraction, and dark-field signals with laboratory x-ray sources

We present the translation of the beam tracking approach for x-ray phase-contrast and dark-field imaging, recently demonstrated using synchrotron radiation, to a laboratory setup. A single absorbing mask is used before the sample, and a local Gaussian interpolation of the beam at the detector is used to extract absorption, refraction, and dark–field signals from a single exposure of the sample. Multiple exposures can be acquired when high resolution is needed, as shown here. A theoretical analysis of the effect of polychromaticity on the retrieved signals, and of the artifacts this might cause when existing retrieval methods are used, is also discussed.

43 PARTICLE ACCELERATORS↗

Time-resolved fast-neutron radiography of air-water two-phase flows in a rectangular channel by an improved detection system

In a previous work, we have demonstrated the feasibility of high-frame-rate, fast-neutron radiography of generic air-water two-phase flows in a 1.5 cm thick, rectangular flow channel. The experiments have been carried out at the high-intensity, white-beam facility of the Physikalisch-Technische Bundesanstalt, Germany, using an multi-frame, time-resolved detector developed for fast neutron resonance radiography. The results were however not fully optimal and therefore we have decided to modify the detector and optimize it for the given application, which is described in the present work. Furthermore, we managed to improve the image post-processing methodology and the noise suppression. Using the tailored detector and the improved post-processing, significant increase in the image quality and an order of magnitude lower exposure times, down to 3.33 ms, have been achieved with minimized motion artifacts. Similar to the previous study, different two-phase flow regimes such as bubbly slug and churn flows have been examined. The enhanced imaging quality enables an improved prediction of two-phase flow parameters like the instantaneous volumetric gas fraction, bubble size, and bubble velocities. Instantaneous velocity fields around the gas enclosures can also be more robustly predicted using optical flow methods as previously.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Co{sub 2}FeAl based magnetic tunnel junctions with BaO and MgO/BaO barriers

We succeed to integrate BaO as a tunneling barrier into Co{sub 2}FeAl based magnetic tunnel junctions (MTJs). By means of Auger electron spectroscopy it could be proven that the applied annealing temperatures during BaO deposition and afterwards do not cause any diffusion of Ba neither into the lower Heusler compound lead nor into the upper Fe counter electrode. Nevertheless, a negative tunnel magnetoresistance (TMR) ratio of -10% is found for Co{sub 2}FeAl (24 nm) / BaO (5 nm) / Fe (7 nm) MTJs, which can be attributed to the preparation procedure and can be explained by the formation of Co- and Fe-oxides at the interfaces between the Heusler and the crystalline BaO barrier by comparing with theory. Although an amorphous structure of the BaO barrier seems to be confirmed by high-resolution transmission electron microscopy (TEM), it cannot entirely be ruled out that this is an artifact of TEM sample preparation due to the sensitivity of BaO to moisture. By replacing the BaO tunneling barrier with an MgO/BaO double layer barrier, the electric stability could effectively be increased by a factor of five. The resulting TMR effect is found to be about +20% at room temperature, although a fully antiparallel state has not been realized.

36 MATERIALS SCIENCE↗

Current and surface charge modified hysteresis loops in ferroelectric thin films

Polarization domains in ferroelectric materials and the ability to orient them with an external electric field lead to the development of a variety of applications from information storage to actuation. The development of piezoresponse force microscopy (PFM) has enabled researchers to investigate ferroelectric domains and ferroelectric domain switching on the nanoscale, which offers a pathway to study structure-function relationships in this important material class. Due to its commercial availability and ease of use, PFM has become a widely used research tool. However, measurement artifacts, i.e., alternative signal origins besides the piezoelectric effect are barely discussed or considered. This becomes especially important for materials with a small piezoelectric coefficient or materials with unknown ferroelectric properties, including non-ferroelectric materials. Here, the role of surface charges and current flow during PFM measurements on classical ferroelectrics are discussed and it will be shown how they alter the PFM hysteresis loop shape. This will help to better address alternative signal origins in PFM-type experiments and offer a pathway to study additional phenomena besides ferroelectricity.

36 MATERIALS SCIENCE↗

Two-dimensional wave-number spectral analysis techniques for phase contrast imaging turbulence imaging data on large helical device

An analysis method for unfolding the spatially resolved wave-number spectrum and phase velocity from the 2D CO{sub 2} laser phase contrast imaging system on the large helical device is described. This is based on the magnetic shear technique which identifies propagation direction from 2D spatial Fourier analysis of images detected by a 6 × 8 detector array. Because the strongest modes have wave-number at the lower end of the instrumental k range, high resolution spectral techniques are necessary to clearly resolve the propagation direction and hence the spatial distribution of fluctuations along the probing laser beam. Multiple-spatial point cross-correlation averaging is applied before calculating the spatial power spectrum. Different methods are compared, and it is found that the maximum entropy method (MEM) gives best results. The possible generation of artifacts from the over-narrowing of spectra are investigated and found not to be a significant problem. The spatial resolution Δρ (normalized radius) around the peak wave-number, for conventional Fourier analysis, is ∼0.5, making physical interpretation difficult, while for MEM, Δρ ∼ 0.1.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗