Transarterial Chemoembolization With Cisplatin as Second-Line Treatment for Hepatocellular Carcinoma Unresponsive to Chemoembolization With Epirubicin-Lipiodol Emulsion

Purpose: The purpose of this retrospective study was to investigate the efficacy of transarterial chemoembolization (TACE) using cisplatin as a second-line treatment for advanced hepatocellular carcinoma (HCC) unresponsive to TACE using epirubicin-Lipiodol emulsion at our institution. Materials and Methods: Between January 2006 and March 2009, 51 patients with unresectable HCC underwent TACE using cisplatin. All patients had shown persistent viable tumor or tumor progression after at least 2 sessions of TACE using epirubicin-Lipiodol emulsion. TACE procedures consisted of arterial injection of a mixture of Lipiodol and cisplatin (30-100 mg [mean 57 {+-} 21]) (n = 29) or arterial infusion of cisplatin (30-100 mg [mean 87 {+-} 19]) solution (n = 22) followed by injection of 1-mm porous gelatin particles. Early tumor response was assessed by contrast-enhanced computed tomography (CT) according to Response Evaluation Criteria in Solid Tumors (RECIST) and European Association for the Study of the Liver (EASL) criteria. Overall survival and progression-free survival was calculated using the Kaplan-Meier method. Toxicity was assessed according to NCI-CTCAE version 3 criteria. Results: Response rates were 11.8 and 27.5% by RECIST and EASL criteria, respectively. Overall survival rates were 61.9, 48.2, and 28.9% at 1, 2, and 3 years, respectively, and the median survival time was 15.4 months. Progression-free survival rate was 35.2% at 1 year, and median progression-free survival time was 3.1 months. No major complications were observed, and the occurrence of postembolization syndrome was minimal. Grade 3 to 4 toxicities included thrombocytopenia (5.8%), increased aspartate aminotransferase (AST) level (35.3%), and increased alanine aminotransferase (ALT) level (23.5%). Conclusions: witching the TACE anticancer drug from epirubicin to cisplatin might be the feasible option for advanced HCC, even when considered resistant to the initial form of TACE.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Irinotecan Loaded in Eluting Beads: Preclinical Assessment in a Rabbit VX2 Liver Tumor Model

Purpose: The purpose of this study was to study the pharmacokinetics of irinotecan injected intravenously, intra-arterially, or loaded onto a delivery platform. Material and Methods: Fifty-four New Zealand White rabbits with VX2 liver tumor, divided in 3 groups of 17 rabbits, each received irinotecan either by intravenous (IV) route, intra-arterial hepatic (IA) route, or loaded on drug-eluting beads (DEBIRI). Animals were killed at 1, 6, and 24 h. Irinotecan and SN-38 concentrations were measured at different time points in serum, tumor, and normal liver.ResultsTwelve milligrams of irinotecan were injected IV and IA, whereas 6-16.5 mg were injected loaded onto DEBIRI. Normalized serum irinotecan reached a peak of 333 ng/ml (range 198.8-502.5) for IV, 327.1 ng/ml (range 277.1-495.6) for IA, and 189.7 ng/ml (range 111.1-261.9) for DEBIRI (P < 0.001) delivery. The area-under-the-curve value from 10 to 60 min of serum irinotecan concentration was significantly lower for DEBIRI (P = 0.0009). Tumor irinotecan levels for IV, IA, and DEBIRI (in ng/200 mg of tissue followed by ranges in parentheses) were, respectively, 23.6 (0.3-24.9), 36.5 (7.7-1914.1), and 20.2 (2.9-319) at 1 h; 4.2 (1-27.9), 99.3 (46.6-159.5), and 42.1 (11.3-189) at 6 h; and 2.7 (2.5-6.9), 18.3 (1.5-369.1), and 174.4 (3.4-5147.3) at 24 h (P = 0.02). At 24 h, tumor necrosis was 25% (10-30), 60% (40-91.25), and 95% (76.25-95) for IV, IA, and DEBIRI, respectively (P = 0.03). Conclusion: Compared with IV or IA, DEBIRI induces lower early serum levels of irinotecan, a high and prolonged intratumoral level of irinotecan, and a greater rate of tumor necrosis at 24 h. Further evaluation of the clinical benefit of DEBIRI is warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Neointimal Hyperplasia after Silverhawk Atherectomy versus Percutaneous Transluminal Angioplasty (PTA) in Femoropopliteal Stent Reobstructions: A Controlled, Randomized Pilot Trial

Due to intimal hyperplasia instent reobstruction in the femoropopliteal arterial segment is still an unsolved problem. Different techniques have been discussed in case of reintervention to guarantee longlasting patency rate. We conducted a randomized, controlled, pilot trial comparing Silverhawk atherectomy with percutaneous transluminal angioplasty (PTA) in patients with a first instent reobstruction in the femoropopliteal arterial segment, to evaluate intima media thickness (IMT) within the treated segment, as a parameter of recurrence of intimal hyperplasia. In a total 19 patients were included: 9 patients in the atherectomy device and 10 patients in the PTA arm. IMT within the treated segment was statistically significantly elevated in all patients treated with the Silverhawk device versus the patients treated with PTA. The obvious differentiation in elevation of IMT in nonfavor for patients treated with the Silverhawk device started at month 2 (max IMT SH 0.178 mm vs. IMT PTA 0.1 mm, p = 0.001) with a spike at month 5 (max IMT SH 0.206 mm vs. IMT PTA 0.145 mm, p = 0.003) and a decline once again at month 6 (max IMT SH 0.177 mm vs. IMT PTA 0.121 mm, p = 0.02). The values for mean IMT performed the same way. Although Silverhawk atherectomy provides good results at first sight, in the midterm follow-up of treatment of first instent restenosis it did not perform better than PTA as it showed elevated reoccurrence of intimal media hyperplasia.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Flat-Panel Cone-Beam Ct-Guided Radiofrequency Ablation of Very Small (≤1.5 cm) Liver Tumors: Technical Note on a Preliminary Experience

PurposeThe aim of the present study was to investigate the technical feasibility of flat-panel cone-beam CT (CBCT)-guided radiofrequency ablation (RFA) of very small (<1.5 cm) liver tumors.Materials and MethodsPatients included were candidates for hepatic percutaneous RFA as they had single biopsy-proven hepatic tumors sized ≤1.5 cm and poorly defined on ultrasonography. Following apnea induction, unenhanced CBCT scans were acquired and used to deploy the RF electrode with the aid of a virtual navigation system. If the tumor was not clearly identified on the unenhanced CBCT scan, a right retrograde arterial femoral access was established to carry out hepatic angiography and localize the tumor. Patients’ lesions and procedural variables were recorded and analyzed.ResultsThree patients (2 male and 1 female), aged 68, 76, and 87 years were included; 3 lesions (2 hepato-cellular carcinoma and 1 metastasis from colorectal cancer) were treated. One patient required hepatic angiography. Cycles of apnea used to acquire CBCT images and to deploy the electrode lasted <120 s. Mean fluoroscopic time needed to deploy the electrode was 36.6 ± 5.7 min. Mean overall procedural time was 66.0 ± 22.9 min. No peri- or post-procedural complications were noted. No cases of incomplete ablation were noted at 1-month follow-up.ConclusionPercutaneous CBCT-guided liver RFA with or without arterial hepatic angiography is technically feasible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impact of 3D Rotational Angiography on Liver Embolization Procedures: Review of Technique and Applications

In the last years, the interest into interventional applications of C-arm cone-beam CT (CBCT) progressively raised, widening its clinical application from the original field of interventional neuroradiology to the field of peripheral procedures. Liver embolization procedures, due to their complexity and potential treatment-related life-threatening complications, represent one of the main clinical applications of this novel angiographic technique. CBCT has been demonstrated to render procedures safer and technically easier, and to predict outcome as well as to avoid major complications in different treatment scenarios (trans-arterial embolization, trans-arterial chemoembolization, selective internal radiation therapy, percutaneous portal vein embolization). This review summarizes all technical, dosimetric and procedural aspects of CBCT techniques, underlying all its potential clinical advantages in the field of liver embolization procedures. Moreover, the paper provides all the instructions to obtain the best diagnostic performance out of this novel angiographic technique.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Delayed-Phase Cone-Beam CT Improves Detectability of Intrahepatic Cholangiocarcinoma During Conventional Transarterial Chemoembolization

PurposeTo evaluate the detectability of intrahepatic cholangiocarcinoma (ICC) on dual-phase cone-beam CT (DPCBCT) during conventional transarterial chemoembolization (cTACE) compared to that of digital subtraction angiography (DSA) with respect to pre-procedure contrast-enhanced magnetic resonance imaging (CE-MRI) of the liver.MethodsThis retrospective study included 17 consecutive patients (10 male, mean age 64) with ICC who underwent pre-procedure CE-MRI of the liver, and DSA and DPCBCT (early-arterial phase (EAP) and delayed-arterial phase (DAP)) just before cTACE. The visibility of each ICC lesion was graded by two radiologists on a three-rank scale (complete, partial, and none) on DPCBCT and DSA images, and then compared to pre-procedure CE-MRI.ResultsOf 61 ICC lesions, only 45.9 % were depicted by DSA, whereas EAP- and DAP-CBCT yielded a significantly higher detectability rate of 73.8 % and 93.4 %, respectively (p < 0.01). Out of the 33 lesions missed on DSA, 18 (54.5 %) and 30 (90.9 %) were revealed on EAP- and DAP-CBCT images, respectively. DSA depicted only one lesion that was missed by DPCBCT due to streak artifacts caused by a prosthetic mitral valve. DAP-CBCT identified significantly more lesions than EAP-CBCT (p < 0.01). Conversely, EAP-CBCT did not detect lesions missed by DAP-CBCT. For complete lesion visibility, DAP-CBCT yielded significantly higher detectability (78.7 %) compared to EAP (31.1 %) and DSA (21.3 %) (p < 0.01).ConclusionDPCBCT, and especially the DAP-CBCT, significantly improved the detectability of ICC lesions during cTACE compared to DSA. We recommend the routine use of DAP-CBCT in patients with ICC for per-procedure detectability and treatment planning in the setting of TACE.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Closure Devices for Iatrogenic Thoraco-Cervical Vascular Injuries

IntroductionThe unintentional arterial placement of a central venous line can have catastrophic complications. The purpose of this systematic review is to assess and analyse the available evidence regarding the use of the various vascular closure devices (VCDs) for the management of iatrogenic thoraco-cervical arterial injuries (ITCAI).MethodsA systematic review was performed according to PRISMA guidelines.ResultsThirty-two relevant case series and case reports were identified with a total of 69 patients having being studied. In the majority of the studies, plug-based VCDs were used (81%) followed by suture-based devices (19%). The majority of studies reported successful outcomes from the use of VCDs in terms of achieving immediate haemostasis without any acute complications. Long-term follow-up data were only available in nine studies with only one case of carotid pseudoaneurysm being reported after 1-month post-procedure. All other cases had no reported long-term complications. Five studies performed direct or indirect comparisons between VCDs and other treatments (open surgery or stent grafting) suggesting no significant differences in safety or effectiveness.ConclusionAlthough there is limited evidence, VCDs appear to be safe and effective for the management of ITCAIs. Further research is warranted regarding the effectiveness of this approach in comparison to surgery and in order to identify those patients who are more likely to benefit from this minimally invasive approach.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Balloon-Assisted Chemoembolization Using a Micro-Balloon Catheter Alongside a Microcatheter for a Hepatocellular Carcinoma with a Prominent Arterioportal Shunt: A Case Report

Although transcatheter arterial chemoembolization is one of the established treatments for hepatocellular carcinoma (HCC), it is difficult to treat HCCs with prominent arterioportal (AP) shunts because anticancer drugs and embolic materials migrate into the non-tumorous liver through the AP shunts and may cause liver infarction. We developed a novel method of balloon-assisted chemoembolization using a micro-balloon catheter alongside a microcatheter simultaneously inserted through a single 4.5-Fr guiding sheath, comprising proximal chemoembolization with distal arterial balloon occlusion. We applied this method to treat an HCC with a prominent distal AP shunt induced by previous proton beam therapy and achieved successful chemoembolization without non-tumorous liver infarction under temporal balloon occlusion of a distal AP shunt.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Factors Affecting Optimal Aortic Remodeling After Thoracic Endovascular Aortic Repair of Type B (IIIb) Aortic Dissection

PurposeThe purpose of this study was to determine factors associated with entire aortic remodeling after thoracic endovascular aortic repair (TEVAR) in patients with type B dissection.Materials and MethodsThe patients with type B (IIIb) dissections who underwent TEVAR from 2006 to 2013 with minimum of 2 years of follow-up computed tomography data were retrospectively reviewed. Based on the status of false lumen remodeling of entire aorta, patients were divided into three groups: complete regression, total thrombosis, and inadequate regression with patent abdominal false lumen.ResultsA total of 90 patients (72 males, 18 females; mean age 56.6 ± 16.4 years) were included and divided into the complete regression (n = 22), total thrombosis (n = 18), and inadequate regression (n = 50) groups. Multivariate logistic regression analysis indicated that dissection extension to iliac arteries, increased preoperative number of dissection tear over abdominal aorta, and decreased preoperative abdominal aorta bifurcation true lumen ratio, as compared between the inadequate and complete regression groups, were associated with a persistent false lumen (odds ratio = 33.33, 2.304, and 0.021; all, p ≤ 0.012). Comparison of 6, 12, and 24 months postoperative data revealed no significant differences at any level, suggesting that the true lumen area ratio might not change after 6 months postoperatively.ConclusionsIncreased preoperative numbers of dissection tear around the abdominal visceral branches, dissection extension to the iliac arteries, and decreased preoperative true lumen area ratio of abdominal aorta are predictive of entire aortic remodeling after TEVAR in patients with type B dissection.Level of EvidenceIII.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multipath Curved Planar Reformations of Peripheral CT Angiography: Diagnostic Accuracy and Time Efficiency

ObjectivesTo compare diagnostic performance and time efficiency between 3D multipath curved planar reformations (mpCPRs) and axial images of CT angiography for the pre-interventional assessment of peripheral arterial disease (PAD), with digital subtraction angiography as the standard of reference.MethodsForty patients (10 females, mean age 72 years), referred to CTA prior to endovascular treatment of PAD, were prospectively included and underwent peripheral CT angiography. A semiautomated toolbox was used to render mpCPRs. Twenty-one arterial segments were defined in each leg; for each segment, the presence of stenosis > 70% was assessed on mpCPRs and axial images by two readers, independently, with digital subtraction angiography as gold standard.ResultsBoth readers reached lower sensitivity (Reader 1: 91 vs. 94%, p = 0.08; Reader 2: 89 vs. 93%, p = 0.03) but significantly higher specificity (Reader 1: 94 vs. 89%, p < 0.01; Reader 2: 96 vs. 95%, p = 0.01) with mpCPRs than with axial images. Reader 1 achieved significantly higher accuracy with mpCPRs (93 vs. 91%, p = 0.02), and Reader 2 had similar overall accuracy in both evaluations (94 vs. 94%, p = 0.96). Both readers read mpCPRs significantly faster than axial images (Reader 1: 5′45″ based on mpCPRs vs. 7′40″ based on axial images; Reader 2: 4′41″ based on mpCPRs vs. 6′57″ based on axial images; p < 0.01).ConclusionsmpCPRs are a promising 3D reformation technique that facilitates a fast assessment of PAD with high diagnostic accuracy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Arms Down Cone Beam CT Hepatic Angiography Performance Assessment: Vascular Imaging Quality and Imaging Artifacts

IntroductionThe practice of positioning patients’ arms above the head during catheter-injected hepatic arterial phase cone beam CT (A-CBCT) imaging has been inherited from standard CT imaging due to image quality concerns, but interrupts workflow and extends procedure time. We sought to assess A-CBCT image quality and artifacts with arms extended above the head versus down by the side.MethodsWe performed an IRB approved retrospective evaluation of reformatted and 3D-volume rendered images from 91 consecutive A-CBCTs (43 arms up, 48 arms down) acquired during hepatic tumor arterial embolization procedures. Two interventional radiologists reviewed all A-CBCT imaging and assigned vessel visualization scores (VVS) from 1 to 5, ranging from non-diagnostic to optimal visualization. Streak artifacts across axial images were rated from 1 to 3 based on resulting image quality (none to significant). Presence of respiratory or cardiac motion during acquisition, body mass index and radiation dose area product (DAP) were also recorded and analyzed. Univariate and multivariate analyses were used to assess the impact of arm position on VVS and imaging artifacts.ResultsVVS were not significantly associated with arm position during A-CBCT imaging. One reader reported more streak artifacts across axial images in the arms down group (p = 0.005). DAP was not statistically different between the groups (23.9 Gy cm{sup 2} [6.1–73.4] arms up, 26.1 Gy cm{sup 2} [4.2–102.6] arms down, p = 0.54).ConclusionA-CBCT angiography performed with the arms above the head is not superior for clinically relevant hepatic vascular visualization compared to imaging performed with the arms by the patient’s side.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluating the Feasibility of Isolated Pancreatic Perfusion for Chemotherapy Using Computed Tomography: An Experimental Study in Pig Models

PurposePercutaneous isolated pancreatic perfusion (PIPP) is performed along with interventional radiology techniques to obtain high drug concentration by occluding the arterial inlet and venous outlet of the pancreas. The experimental study aimed to evaluate the contrast distribution in PIPP under different flow rates with or without anterior mesenteric artery (AMA) occlusion.Materials and MethodsThis study was approved by a local animal experiment ethics committee. Nine pigs were divided into Groups 1, 2, and 3, by infusion rates of 12, 24, and 36 mL/min. Groups 4 and 5 (3 pigs each) and Group 6 (2 pigs) underwent PIPP at the same respective infusion rates with and without AMA occlusion. Computed tomography (CT) arteriography was performed during PIPP with nonionic contrast media. The enhanced volume was calculated by adding the enhanced area in each slice using 1.25-mm axial images. The percent enhanced volume to the whole pancreas (%eV) was used to simulate drug distribution; the result was compared among groups.ResultsWithout AMA occlusion, a larger %eV was obtained with high infusion rates (P = 0.039). The median %eV in Groups 1, 2, and 3 were 57.7, 74.2, and 90.5%, respectively. With AMA occlusion, CT demonstrated duodenal enhancement at an infusion rate of 36 mL/min, and the median %eV in Groups 4, 5, and 6 were 92.8, 95.4, and 98.5%, respectively. A significantly larger %eV was obtained after AMA occlusion (P = 0.031).ConclusionA higher infusion rate or AMA occlusion increases the enhanced volume in PIPP in pig models. Level of evidence: No level of evidence.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Imaging and Endovascular Treatment of Bleeding Pelvic Fractures: Review Article

Pelvic fractures are potentially life-threatening injuries with high mortality rates, mainly due to intractable pelvic arterial bleeding. However, concomitant injuries are frequent and may also be the cause of significant blood loss. As treatment varies depending on location and type of hemorrhage, timely imaging is of critical importance. Contrast-enhanced CT offers fast and detailed information on location and type of bleeding. Angiography with embolization for pelvic fracture hemorrhage, particularly when performed early, has shown high success rates as well as low complication rates and is currently accepted as the first method of bleeding control in pelvic fracture-related arterial hemorrhage. In the current review imaging workup, patient selection, technique, results and complications of pelvic embolization are described.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Double-Barreled and Branched Endografting for Thoracoabdominal Aortic Aneurysm: The Hexapus Technique

Objective: To treat thoracoabdominal aortic aneurysm (TAAA), we introduced an alternative “Hexapus” technique by double-barreled and branched endografting. Technique and Result: We established 2 transfemoral and 2 transaxillary access routes first and then deployed two abdominal bifurcated stentgrafts landing at the descending thoracic aorta through transfemoral routes, respectively. Two pairs of parallel stentgrafts were deployed via bilateral transaxillary route from each of contralateral limbs of main body stentgrafts to visceral arteries. Finally, we extended the ipsilateral limbs of main body stentgrafts to bilateral common iliac arteries as distal landings. The creation of six branches (four viscerals and two iliacs) resembles a hexapus. We have executed this Hexapus technique in three patients, and the final angiography during operation and postoperative 12-month image follow-up showed patent visceral branches and no any endoleaks. Conclusion: Our Hexapus technique is feasible in treating TAAA if patient is inoperable or no commercial fenestrated or branched stentgraft is available.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Neck Stabilization Before EVAR for Infrarenal Aortic Aneurysm in Chronic Aortic Dissection

Background: Endovascular treatment of infrarenal abdominal aortic aneurysm (AAA) with proximal chronic aortic dissection is challenging as a false and true lumen at the level of the infra-renal neck does not allow a sufficient landing zone. We describe staged endovascular neck stabilization prior to standard endovascular aortic repair (EVAR) for AAA with chronic aortic dissection. Technique: To create a stable proximal neck (PN) by closing entry tears, thereby resulting in total false lumen thrombosis (FLT) prior to standard EVAR. Case 1 false lumen fenestrations were present at the descending aorta, the right renal artery orifice and PN. After closing the entry tear by thoracic EVAR, an aortic cuff was placed in the true lumen of the PN and renal stenting for the right renal artery was performed. After 2 months, total FLT was achieved, and EVAR was performed. Case 2 false lumen fenestrations were present at the descending, super celiac aorta and PN. After closing the entry by TEVAR, aortic cuffs were placed at infrarenal aorta to close residual entries. After 1 month of achieving total FLT, EVAR was performed. Both cases had no type 1 endoleak during follow-up. Conclusion: The endovascular neck stabilization is a useful treatment option that facilitates standard EVAR for AAA in chronic aortic dissection.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiation effects on atherosclerosis in atomic bomb survivors: a cross-sectional study using structural equation modeling

Past reports indicated that total-body irradiation at low to moderate doses could be responsible for cardiovascular disease risks, but the mechanism remains unclear. The purpose of this study was to investigate the association between radiation exposure and atherosclerosis, an underlying pathology of cardiovascular diseases, in the Japanese atomic bomb survivors. We performed a cross-sectional study measuring 14 clinical-physiological atherosclerosis indicators during clinical exams from 2010 to 2014 in 3274 participants of the Adult Health Study cohort. Multivariable analyses were performed by using a structural equation model with latent factors representing underlying atherosclerotic pathologies: (1) arterial stiffness, (2) calcification, and (3) plaque as measured with indicators chosen a priori on the basis of clinical-physiological knowledge. Radiation was linearly associated with calcification (standardized coefficient per Gy 0.15, 95 % confidence interval: CI [0.070, 0.23]) and plaque (0.11, 95 % CI [0.029, 0.20]), small associations that were comparable to about 2 years of aging per Gy of radiation exposure, but not with arterial stiffness (0.036, 95 % CI [-0.025, 0.095]). The model fitted better and had narrower confidence intervals than separate ordinary regression models explaining individual indicators independently. The associations were less evident when the dose range was restricted to a maximum of 2 or 1 Gy. By combining individual clinical-physiological indicators that are correlated because of common, underlying atherosclerotic pathologies, we found a small, but significant association of radiation with atherosclerosis.

59 BASIC BIOLOGICAL SCIENCES↗

A multifunctional CT technology: Reality or illusion for patient risk assessment?

A high-speed, multi-slice coronary computed tomography (CT) imaging has emerged as a promising or clinically available multifunctional technique for the assessment of myocardial ischemia, viability, ischemia-induced cardiac dysfunction, and coronary atherosclerotic alterations in patients with suspected or known coronary artery disease. Despite several technical issues remain to be resolved, cardiac CT imaging will have a reality as a multifunctional modality for guiding physicians in better decision-making for favorable clinical outcomes in patients with suspected coronary artery disease, provided that this imaging technology can contribute to characterization and localization of high-risk coronary atherosclerosis in combination with the quantitative evaluation of functional myocardial ischemia.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Noninvasive PET quantitative myocardial blood flow with regadenoson for assessing cardiac allograft vasculopathy in orthotopic heart transplantation patients

Background: Risk stratification and early detection of cardiac allograft vasculopathy (CAV) is essential in orthotopic heart transplantation (OHT) patients. This study assesses the changes in myocardial blood flow (MBF) noninvasively in OHT patients using quantitative cardiac PET with regadenoson. Methods: Twelve patients (Group 1) (8 males, 4 females, mean age 55 ± 7 years) with no history of post OHT myocardial ischemia were enrolled 5.4 ± 2.0 years after OHT. Fifteen patients (Group 2) (9 males, 6 females, mean age 71 ± 9 years) with intermediate pretest probability but not documented evidence for coronary artery disease (CAD) were also included to serve as control. Global and regional MBFs were assessed using dynamic {sup 13}N-NH{sub 3} PET at rest and during regadenoson-induced hyperemia. The coronary flow reserve (CFR) was also calculated as the ratio of hyperemic to resting MBF. Results: Mean regadenoson-induced rate-pressure products were similar in both groups, while there was an increase in resting rate-pressure product in Group 1 patients. Both mean and median values of resting MBF were higher in Group 1 than Group 2 patients (1.33 ± 0.31 and 1.01 ± 0.21 mL/min/g for Groups 1 and 2, respectively, P < .001), while mean hyperemic MBF values were similar in both Groups (2.68 ± 0.84 and 2.64 ± 0.94 mL/min/g, P = NS) but median hyperemic MBF values were lower in Group 1 than Group 2 patients (2.0 vs. 2.60 mL/min/g, P = .018). Both mean and median CFR values demonstrated a significant reduction for Group 1 compared to Group 2 patients (2.07 ± 0.74 vs 2.63 ± 0.48, P = .025). Conclusions: This study suggests that the MBF in OHT patients may be abnormal at resting state with diminished CFR. This hints that the epicardial and microvascular coronary subsystem may be exacerbated after OHT leading to the gradual progression of CAV. [French] French Abstract: Contexte: Cette étude pilote par tomographie a positrons évalue de manière quantitative les changements de perfusion myocardique et le risque de vasculopathie coronaire après transplantation cardiaque chez l’être humain. Méthodes: Douze patients (groupe 1) (8 hommes, 4 femmes, âge moyen 55 ± 7 ans) sans antécédents d'ischémie myocardique post-chirurgicale ont été étudiés après 5,4 ± 2,0 ans après transplantation cardiaque. Quinze patients (groupe 2) (9 hommes, 6 femmes, âge moyen 71 ± 9 ans) avec une probabilité intermédiaire mais sans signes objectifs de maladie coronarienne ont servi de contrôles. Les donnes de perfusion myocardique globales et régionales ont été évaluées par tomographie à positrons l'aide de{sup 13}N-NH3 au repos et durant l'hyperémie induite par le vasodilatateur coronarien régadénoson. La réserve de flux coronarien a été calculée sur base du rapport entre le flux myocardique hyperhémique induit par le régadénoson et le flux myocardique au repos. Résultats: les double produits (fréquence cardiaque x tension artérielle) moyens après régadénoson furent similaires chez les deux groups de patients. Par contre le double produit au repos était plus élevé dans le groupe de patient transplantés. Les valeurs moyennes et médianes de perfusion myocardique globale au repos ont été calculées à 1.33 ± 0.31 ml/min/g dans le groupe de patients transplantés et 1.01 ± 0.21 ml/min/g dans le groupe control (P < 0.001). Après régadénoson, les valeurs moyennes de perfusion myocardique se sont avérées similaires dans les deux groupes (2,68 ± 0,84 et 2,64 ± 0,94 ml/min/g, P > 0.05). Néanmoins les valeurs médianes se sont avérées inferieures dans le groupe 1 comparativement au groupe control (2,0 versus 2,60 ml/min/g; P = 0,018). Les valeurs moyennes et médianes de réserve de flux myocardique mesurées étaient significativement réduites chez les patient transplantés (2,07 ± 0,74) en comparaison aux patients du groupe 2 (2,63 ± 0,48; P = 0.025). Conclusion: La perfusion myocardique au repos peut s’avérer anormale après transplantation cardiaque et s’accompagner d’une diminution de la réserve du flux coronaire. Cette étude pilote suggère que les vaisseaux épicardiques et la micro-vascularisation du myocarde peuvent être atteints après transplantation et conduire à la maladie coronaire du greffon. [Spanish] Spanish Abstract: Antecedentes: la estratificación de riesgo y detección temprana de la vasculopatía del aloinjerto cardiaco (VAC) es esencial en los pacientes con trasplante cardiaco ortotópico (TCO). El presente estudio evalúa de forma no invasiva los cambios en el flujo sanguíneo miocárdico (FSM) en pacientes con TCO utilizando el PET cardiaco cuantitativo con regadenoson. Métodos: Doce pacientes (Grupo 1) (8 hombres, 4 mujeres, edad promedio 55 ± 7 años) sin historia de isquemia miocárdica posterior al TCO fueron incluidos después de 5.4 ± 2.0 años de ser trasplantados. Quince pacientes (Grupo 2) (9 hombres, 6 mujeres, edad promedio 71 ± 9 años) con probabilidad pre-prueba intermedia pero sin evidencia documentada de enfermedad arterial coronaria (EAC) fueron incluidos como grupo control. El FSM global y regional fueron evaluados utilizando el estudio PET dinámico con {sup 13}N-NH{sub 3} en reposo y durante la inducción de hiperemia con regadenoson. La reserva de flujo coronario (RFC) también fue calculada como la proporción entre el FSM hiperémico y el de reposo. Resultados: el producto de velocidad-presión promedio inducido por regadenoson fue similar en ambos grupos, mientras que existió un incremento de este producto velocidad-presión durante el reposo en el Grupo 1 de pacientes. Los valores de la media y mediana del FSM de reposo fueron mayores en el Grupo 1 que el Grupo 2 de pacientes (1.33 ± 0.31 y 1.01 ± 0.21 mL/min/g para los Grupos 1 y 2, respectivamente, P < 0.001). La media de los valores del FSM hiperémico fueron similares en ambos grupos (2.68 ± 0.84 and 2.64 ± 0.94 mL/min/g, P = NS), sin embargo la mediana fue menor en el Grupo 1 que en el Grupo 2 (2.0 vs. 2.60 mL/min/g, P = .018). Tanto la media como la mediana para los valores de la RFC demostraron una disminución significativa en el Grupo 1 comparada con el Grupo 2 (2.07 ± 0.74 vs. 2.63 ± 0.48, P = 0.025). Conclusiones: El presente estudio sugiere que el FSM en pacientes con TCO puede estar alterado en reposo con una RFC disminuida. Esto indica que los sistemas coronarios epicardico y microvascular pudieran estar inflamados posterior al TCO conduciendo a una progresión gradual de la VAC. [Chinese] Chinese Abstract: 背景: 对于原位心脏移植 (OHT) 病人, 早期检测移植心脏血管病变 (CAV) 和进行危险分层是必要的。 本研究拟通过类伽腺苷定 心脏 PET 显像, 非侵入性地评估 OHT 病人心肌血流 (MBF) 的变化。 方法: 研究对象分为两组。 第一组, 12个病人 (8 男, 4女, 平均 55 ± 7岁), OHT 后 5.4 ± 2.0 年, 没有 OHT 后心肌缺血。 第二组 (对照组), 15 个病人 (9 男, 6 女, 平均 71 ± 9 岁), 中等冠心病可能, 但尚未确诊。 分别于静息及类伽腺苷药物负荷下, 动态采集 {sup 13}N-NH{sub 3} PET 图像, 获得整体和局部 MBF。冠脉血流储备 (CFR) 通过负荷 MBF /静息 MBF 计算而得。 结果: 类伽腺苷负荷时, 反映心肌耗氧 的心率血压乘积在两组间没有差异, 但在静息时, 第一组明显高于第二组。静息时, 第一组 MBF 的平均值高于第二组 (1.33 ± 0.31 vs. 1.01 ± 0.21 mL/min/g, P < 0.001); 负荷时, 两组 MBF 的平均值无差异 (2.68 ± 0.84 vs. 2.64 ± 0.94 mL/min/g, P = NS), 但 MBF 的中位数第一组要低于第二组 (2.0 vs. 2.60 mL/min/g, P = 0.018), 且第一组 CFR 的平均值明显低于第二组 (2.07 ± 0.74 vs. 2.63 ± 0.48, P = 0.025)。 结论: 在原位心脏移植病人中, 冠脉血流储备以及静息心肌血流 均呈现明显异常。提示原位心脏移植后, 冠状动脉心外膜血管与微小血管功能均受损, 进而将逐渐导致移植心脏血管病变。 关键词: 动态PET, 类伽腺苷, 冠状动脉血流储备, 原位心脏移植, 移植心脏血管病变。.

62 RADIOLOGY AND NUCLEAR MEDICINE↗