Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ABLATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

High-Temperature Sapphire Pressure Sensors for Harsh Environments

The project aimed to develop and characterize an optical pressure sensor capable of withstanding high temperatures, up to 1000 °C. Survivability in harsh environments was enabled using sapphire for both the substrate and the optical fibers, therefore mitigating thermal expansion mismatch. Such material cannot be machined through conventional microfabrication techniques, and unique additive and subtractive methods had to be studied and implemented. Subtractive methods included laser-machining the sapphire substrate using a picosecond laser machining tool. At first, the parameters of importance were theoretically and experimentally evaluated such that the fluence, the pulse spacing, and the number of passes were found to strongly influence the laser ablation process. A simulation tool was designed to predict the final pattern when inputting a set of parameters and a profile. This model was complemented with laser ablation material physics models and Bayesian uncertainty analysis for one dimensional and three dimensional ablation processes. An additive process called thermocompression bonding was studied in order to seal the diaphragm substrate to the back cavity. At first, bonding strength using this technique was examined using the chevron-notch method that allow to determine the fracture toughness of this bond. This parameter is independent of the geometry used and therefore can be extended to other geometries used in actual sensor bonding. A theoretical and experimental study of internal damage caused by the laser micromachining of the sapphire material was carried out. The research identified enhanced strength and fracture toughness along laser ablated surfaces. This was determined using bend bar specimens and Vicker’s microindentations. Softening of the plasticity behavior (as indicated by nanoindentation experiments) was also investigated using finite deformation plasticity modeling via a contact mechanics finite element simulation. Good correlations between experiments and the model were achieved to determine material parameters that can be used in future MEMS based sensor design and modeling to minimize sensor failure loads. The enhanced strength and fracture toughness was determined to be due to compressive residual stress near laser ablated surfaces. This was confirmed through x-ray spectra taken along different crystal structure planes in combination and Bayesian uncertainty analysis. The Bayesian analysis inferred the entire residual strain tensor (six components) and the residual stress tensor. The results illustrated compressive in-plane stress was the most likely cause of enhanced strength and toughness after laser machining. Due to major equipment failures, a parallel route for fabricating the sensor was taken, using commercially available sapphire removal method (subtractive) and ceramic adhesive bonding (additive). The fully-packaged sensor utilized laser micromachining for the sapphire substrate fabrication and was comprised only of high-temperature-compatible materials. Calibration tests of the sensor in both room-temperature and high-temperature plane-wave tubes showed good linearity and consistent frequency response, in the tested frequency range. The sensor also showed good thermal stability in tests up to 300 °C, proving the fiber-optic lever and its packaging process to be a promising approach for high-temperature measurements. The calibration from 23 °C to 300 °C gave a raw sensitivity of 3.9 × 10 -7 V/Pa and a normalized sensitivity of 9.8 × 10 -8 Pa -1 which were consistent within the temperature range. The sensor had a resonance at 16.3 kHz and a flat band (±3 dB) up to 10.3 kHz. The noise floor of the sensor at 1 kHz was 316 nV/Hz 1/2 , resulting in a MDP of 0.8 Pa. Previously, diaphragm delamination due to CTE mismatch was found at 500 °C, causing packaging failure. Unfortunately high temperature validation in hot jet environment could not be made in time. In the future, it is suggested that the two sapphire substrates be bonded by thermal compression bonding with an intermediate platinum layer instead of using an alumina-based adhesive, and therefore achieve higher temperature capacity up to 1000 °C.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

The role of thermal conduction on the size scaling of laser direct-drive implosions

Ablation pressure is a key parameter controlling laser drive performance in direct-drive inertial confinement fusion implosions. In this work, we develop a theoretical framework to clarify the role of thermal conduction in determining how ablation pressure scales with laser intensity, wavelength, and target size. We focus on a steady-state, spherically expanding plasma produced when an over-dense pellet is irradiated by a high-intensity laser. Scaling laws for ablation pressure and the mass ablation rate are derived with respect to laser intensity, wavelength, and target size. As a result, the theoretical predictions are found to be in good agreement with one-dimensional hydrodynamics simulations in spherical geometry.

Ablation↗

Novel Approach for Selective Emitter Formation and Front Side Metallization of Crystalline Silicon Solar Cells

In this project we will explore the possibility of forming the front side metallization and selective emitter layer for the crystalline silicon solar cells through using selective laser ablation to create contact openings on the front surface and a screen printer to make connections with conductive paste. Using this novel approach we expect to reduce the specific contact resistance of the silver gridlines by about one order of magnitude compared to the state-of-art industrial crystalline silicon solar cells to below 1 mΩ∙cm 2 , and use lightly doped n+ emitter layer with sheet resistance of not smaller than 100 Ω. This represents an enabling improvement on crystalline silicon solar cell performance and can increase the absolute efficiency of the solar cell by about 1%. In this scientific report we first present our result on the selective laser ablation of the nitride layer to make contact openings. Then we report our work on the solar cell fabrication by using the laser ablated contact openings with self-doping paste. Through various electrical property characterization and SIMS analysis, the factors limiting the cell performance have been discussed. While through this proof-of-concept project we could not reach the target on cell efficiency improvement, the process to fabricate 125mm full-sized silicon solar cells using laser ablation and self-doping paste has been developed, and a much better understanding of technical challenges has been achieved. Future direction to realize the potential of the new technology has been clearly defined.

14 SOLAR ENERGY↗

Early Indicators of Treatment Success After Percutaneous Radiofrequency of Pulmonary Tumors

We retrospectively reviewed the imaging of patients after radiofrequency ablation (RFA) of lung metastases performed at our institution to assess the usefulness of ground glass opacification (GGO) margin for the prediction of complete tumor ablation. From January 2004 to March 2007, patients were identified where there was a postprocedure thin collimation scan to allow multiplanar reformatting, either immediately or at 24 h and at least 6 months of imaging follow-up. Thirty-six tumors in 22 patients were identified. The scans were assessed for the presence and width of GGO margin, and minimal and maximal dimensions were measured. A second reviewer, blinded to the outcome of the postprocedure assessment, reviewed the follow-up imaging for recurrence. The recurrence group had larger tumors (p = 0.045) and smaller mean minimal GGO margin width (p = 0.0001). Multivariate binary regression analysis confirmed that the minimal GGO margin was significantly (p < 0.005) associated with tumor recurrence. Receiver operator characteristic curve analysis suggests a cutoff of 4.5 mm for complete tumor ablation. There was substantial agreement ({kappa} = 0.759) between the site of absent GGO margin and the site of tumor recurrence. The point on the tumor surface where there is no GGO margin is likely to be the site of future recurrence. In our experience, a circumferential GGO margin of >5 mm is the minimal margion required to ensure complete tumor ablation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optimizing the Protocol for Pulmonary Cryoablation: A Comparison of a Dual- and Triple-Freeze Protocol

The purpose of this study was to compare a double freeze-thaw protocol to a triple freeze-thaw protocol for pulmonary cryoablation utilizing an in vivo porcine lung model. A total of 18 cryoablations were performed in normal porcine lung utilizing percutaneous technique with 9 each in a double- (10-5-10) and triple-freeze (3-3-7-7-5) protocol. Serial noncontrast CT images were obtained during the ablation. CT imaging findings and pathology were reviewed. No imaging changes were identified during the initial freeze cycle with either protocol. However, during the first thaw cycle, a region of ground glass opacity developed around the probe with both protocols. Because the initial freeze was shorter with the triple freeze-thaw protocol, the imaging findings were apparent sooner with this protocol (6 vs. 13 min). Also, despite a shorter total freeze time (15 vs. 20 min), the ablation zone identified with the triple freeze-thaw protocol was not significantly different from the double freeze-thaw protocol (mean diameter: 1.67 {+-} 0.41 cm vs. 1.66 {+-} 0.21 cm, P = 0.77; area: 2.1 {+-} 0.48 cm{sup 2} vs. 1.99 {+-} 0.62 cm{sup 2}, P = 0.7; and circularity: 0.95 {+-} 0.04 vs. 0.96 {+-} 0.03, P = 0.62, respectively). This study suggests that there may be several advantages of a triple freeze-thaw protocol for pulmonary cryoablation, including earlier identification of the imaging findings associated with the ablation, the promise of a shorter procedure time or larger zones of ablation, and theoretically, more effective cytotoxicity related to the additional freeze-thaw cycle.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Minimally Invasive Treatment of Small Renal Tumors: Trends in Renal Cancer Diagnosis and Management

Renal cell carcinoma is a common malignancy causing significant mortality. In recent years abdominal imaging, often for alternate symptomatology, has led the trend toward the detection and confirmation of smaller renal tumors. This has permitted the greater use of localized and nephron-sparing techniques including partial nephrectomy and image-guided ablation. This article aims to review the current role of image-guided biopsy and ablation in the management of small renal tumors. The natural history of renal cell carcinoma, the role of renal biopsy, the principles and procedural considerations of thermal energy ablation, and the oncological outcomes of these minimally invasive treatments are discussed and illustrated with cases from the authors' institution. Image-guided ablation, in particular, has changed the treatment paradigm and, by virtue of its increasingly evident efficacy and low morbidity, now favors the treatment of smaller tumors in patients previously unfit for surgery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Image-Based Monitoring of Magnetic Resonance-Guided Thermoablative Therapies for Liver Tumors

Minimally invasive treatment options for liver tumor therapy have been increasingly used during the last decade because their benefit has been proven for primary and inoperable secondary liver tumors. Among these, radiofrequency ablation has gained widespread consideration. Optimal image-guidance offers precise anatomical information, helps to position interventional devices, and allows for differentiation between already-treated and remaining tumor tissue. Patient safety and complete ablation of the entire tumor are the overriding objectives of tumor ablation. These may be achieved most elegantly with magnetic resonance (MR)-guided therapy, where monitoring can be performed based on precise soft-tissue imaging and additional components, such as diffusion-weighted imaging and temperature mapping. New MR scanner types and newly developed sequence techniques have enabled MR-guided intervention to move beyond the experimental phase. This article reviews the current role of MR imaging in guiding radiofrequency ablation. Signal characteristics of primary and secondary liver tumors are identified, and signal alteration during therapy is described. Diffusion-weighted imaging (DWI) and temperature mapping as special components of MR therapy monitoring are introduced. Practical information concerning coils, sequence selection, and parameters, as well as sequence gating, is given. In addition, sources of artifacts are identified and techniques to decrease them are introduced, and the characteristic signs of residual tumor in T1-, T2-, and DWI are described. We hope to enable the reader to choose MR sequences that allow optimal therapy monitoring depending on the initial signal characteristics of the tumor as well as its size and location in the liver.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Computed Tomography-Guided Interstitial HDR Brachytherapy (CT-HDRBT) of the Liver in Patients with Irresectable Intrahepatic Cholangiocarcinoma

Purpose: This study was designed to investigate the clinical outcome of patients with irresectable, intrahepatic cholangiocarcinoma (IHC) treated with computed tomography (CT)-guided HDR-brachytherapy (CT-HDRBT) for local tumor ablation.MethodFifteen consecutive patients with histologically proven cholangiocarcinoma were selected for this retrospective study. Patients were treated by high-dose-rate internal brachytherapy (HDRBT) using an Iridium-192 source in afterloading technique through CT-guided percutaneous placed catheters. A total of 27 brachytherapy treatments were performed in these patients between 2006 and 2009. Median tumor enclosing target dose was 20 Gy, and mean target volume of the radiated tumors was 131 ({+-} 90) ml (range, 10-257 ml). Follow-up consisted of clinical visits and magnetic resonance imaging of the liver every third month. Statistical evaluation included survival analysis using the Kaplan-Meier method. Results: After a median follow-up of 18 (range, 1-27) months after local ablation, 6 of the 15 patients are still alive; 4 of them did not get further chemotherapy and are regarded as disease-free. The reached median local tumor control was 10 months; median local tumor control, including repetitive local ablation, was 11 months. Median survival after local ablation was 14 months and after primary diagnosis 21 months. Conclusion: In view of current clinical data on the clinical outcome of cholangiocarcinoma, locally ablative treatment with CT-HDRBT represents a promising and safe technique for patients who are not eligible for tumor resection.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An “Off-the-Shelf” System for Intraprocedural Electrical Current Evaluation and Monitoring of Irreversible Electroporation Therapy

IntroductionIrreversible electroporation (IRE) ablation uses a series of brief electric pulses to create nanoscale defects in cell membranes, killing the cells. It has shown promise in numerous soft-tissue tumor applications. Larger voltages between electrodes will increase ablation volume, but exceeding electrical limits may risk damage to the patient, cause ineffective therapy delivery, or require generator restart. Monitoring electrical current for these conditions in real-time enables managing these risks. This capacity is not presently available in clinical IRE generators.MethodsWe describe a system using a Tektronix TCP305 AC/DC Current Probe connected to a TCPA300 AC/DC Current Probe Amplifier, which is read on a computer using a Protek DSO-2090 USB computer-interfacing oscilloscope. Accuracy of the system was tested with a resistor circuit and by comparing measured currents with final outputs from the NanoKnife clinical electroporation pulse generator.ResultsAccuracy of measured currents was 1.64 ± 2.4 % relative to calculations for the resistor circuit and averaged 0.371 ± 0.977 % deviation from the NanoKnife. During clinical pulse delivery, the system offers real-time evaluation of IRE procedure progress and enables a number of methods for identifying approaching issues from electrical behavior of therapy delivery, facilitating protocol changes before encountering therapy delivery issues.ConclusionsThis system can monitor electrical currents in real-time without altering the electric pulses or modifying the pulse generator. This facilitates delivering electric pulse protocols that remain within the optimal range of electrical currents—sufficient strength for clinically relevant ablation volumes, without the risk of exceeding safe electric currents or causing inadequate ablation.

60 APPLIED LIFE SCIENCES↗

MWA Versus RFA for Perivascular and Peribiliary CRLM: A Retrospective Patient- and Lesion-Based Analysis of Two Historical Cohorts

PurposeTo retrospectively analyse the safety and efficacy of radiofrequency ablation (RFA) versus microwave ablation (MWA) in the treatment of unresectable colorectal liver metastases (CRLM) in proximity to large vessels and/or major bile ducts.Method and MaterialsA database search was performed to include patients with unresectable histologically proven and/or {sup 18}F–FDG–PET avid CRLM who were treated with RFA or MWA between January 2001 and September 2014 in a single centre. All lesions that were considered to have a peribiliary and/or perivascular location were included. Univariate logistic regression analysis was performed to assess the distribution of patient, tumour and procedure characteristics. Multivariate logistic regression was used to correct for potential confounders.ResultsTwo hundred and forty-three patients with 774 unresectable CRLM were ablated. One hundred and twenty-two patients (78 males; 44 females) had at least one perivascular or peribiliary lesion (n = 199). Primary efficacy rate of RFA was superior to MWA after 3 and 12 months of follow-up (P = 0.010 and P = 0.022); however, after multivariate analysis this difference was non-significant at 12 months (P = 0.078) and vanished after repeat ablations (P = 0.39). More CTCAE grade III complications occurred after MWA versus RFA (18.8 vs. 7.9 %; P = 0.094); biliary complications were especially common after peribiliary MWA (P = 0.002).ConclusionFor perivascular CRLM, RFA and MWA are both safe treatment options that appear equally effective. For peribiliary CRLM, MWA has a higher complication rate than RFA, with similar efficacy. Based on these results, it is advised to use RFA for lesions in the proximity of major bile ducts.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Whole-Gland Prostate Cancer Cryoablation with Magnetic Resonance Imaging Guidance: One-Year Follow-Up

PurposePatients who develop prostate cancer after prior abdominal perineal resection are poor surgical candidates, and have limited treatment options. Therefore, our goal is to present results from a single institutional experience of four patients who underwent whole gland MRI-guided cryoablation with a history complicated by prior abdominoperineal resection.Materials and MethodsFour MRI-guided cryoablative treatments (mean age 64, range 59-69 years) for primary and locally recurrent prostate adenocarcinoma were retrospectively reviewed in patients with prior abdominal perineal resection for colorectal cancer (3) and juvenile polyposis (1). Average prostate volume prior to ablation was 23 cc, with an average PSA of 5.6 ng/mL. For each gland, 7-10 cryoprobes were placed approximately 0.5 cm apart in the prostate gland under MRI guidance by a transperineal approach with 3-4 freeze-thaw cycles performed. Each patient had follow up imaging and PSA measurements out to 12 months post ablation.ResultsAll four patient’s PSA dropped below 0.1 ng/mL at 3-6 month post-ablation and remained at these levels at 12 months. Three of the 4 patients had PSA measurements to 33 months post-ablation, with no evidence of recurrence. No patient developed urinary incontinence due to the whole gland cryoablation.ConclusionWith all four patients in our study having undetectable PSAs 12 months post ablation, and with no patient developing urinary incontinence due to the cryoablation, MRI-guided cryoablation appears to be a promising treatment option in patients who are poor surgical candidates due to prior pelvic surgery and/or radiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Concept of a Hybrid Pulsed Plasma Thruster for Small-Size Space Satellites

A concept of a hybrid plasma source to be used as a micro satellite thruster is proposed, where the propellant is a liquid gallium–indium alloy. The plasma source operates in two modes: 1) generation of laser ablation plasma and 2) generation of plasma in a laser-triggered, low-voltage vacuum-arc discharge. The cathode in the discharge cell of the source represents a stainless-steel capillary filled with the working liquid. The laser beam target is the working liquid meniscus. Without any voltage in the discharge gap, only laser-ablated plasma is generated. Upon application of even a relatively low voltage (<1 kV), the ablation initiates a high-current vacuum-arc discharge. In the experiments, the discharge current and voltage waveforms were recorded and so were the images of plasma glow obtained with a HSFC-Pro 4-channel high-speed camera. Regularities of current flow in the high-current vacuum-arc discharge, initiated by the cathode laser ablation, are investigated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Pulsed laser interactions with space debris: Target shape effects

Among the approaches to the proposed mitigation and remediation of the space debris problem is the de-orbiting of objects in low Earth orbit through irradiation by ground-based high-intensity pulsed lasers. Laser ablation of a thin surface layer causes target recoil, resulting in the depletion of orbital angular momentum and accelerated atmospheric re-entry. However, both the magnitude and direction of the recoil are shape dependent, a feature of the laser-based remediation concept that has received little attention. Since the development of a predictive capability is desirable, we have investigated the dynamical response to ablation of objects comprising a variety of shapes. We derive and demonstrate a simple analytical technique for calculating the ablation-driven transfer of linear momentum, emphasizing cases for which the recoil is not exclusively parallel to the incident beam. For the purposes of comparison and contrast, we examine one case of momentum transfer in the low-intensity regime, where photon pressure is the dominant momentum transfer mechanism, showing that shape and orientation effects influence the target response in a similar, but not identical, manner. As a result, we address the related problem of target spin and, by way of a few simple examples, show how ablation can alter the spin state of a target, which often has a pronounced effect on the recoil dynamics.

42 ENGINEERING↗

Femtosecond laser induced breakdown spectroscopy of Cu at the micron/sub-micron scale

While femtosecond Laser Induced Breakdown Spectroscopy has been studied in the macro-scale (i.e. ablation crater sizes of tens to hundreds of micrometers), the spectral emission mechanisms at the micron/sub-micron scale remain largely unknown, mainly because of the challenges associated with spectral emission acquisition from the limited amounts of ablated mass at these small lengthscales. In this work we study the limits of detection, the laser-induced plasma properties and spectral emission efficiency of Cu at the micron/submicron scale. Although the corresponding number electron densities and temperatures are similar to those reported for macroscale laser ablation, our findings suggest less efficient luminous spectral emission per ablated volume as we scale down in laser energy and crater sizes. Furthermore, these results provide a first insight into fs laser-induced plasma properties at the micron/sub-micron scale regime.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sphere-Wall Impact Experiments with Piezoelectric Force Sensors

Measurement of impulse imparted to a target from {mu}s-timescale laser ablation events is often performed with piezoelectric force sensors. For pulsed laser ablation with a target resting on the force sensors, an effect can occur for a vertical thrust stand in an exhaust-up configuration that results in measurement of about twice the actual imparted impulse. A CO{sub 2} laser operating at 10.6 {mu}m wavelength, 300 ns pulse length, and up to 20 J pulse energy single shots was used to ablate samples of PCTFE. Force sensor measurements of the imparted impulse were compared to tests with a ballistic pendulum over a variety of fluences. The theoretical impulse delivered by the impacts of 6 mm diameter spheres of aluminum, steel, POM, and PTFE on the force sensor were studied, and the coefficients of restitution were measured for the targets. Practical issues for measurement of ablation-imparted impulse with piezoelectric sensors are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Laser Patterning of Diamond. Part I. Characterization of Surface Morphology

As the use of diamond as a material for electronic and research applications increases, methods of patterning diamond will be required. In this work, single- and polycrystalline synthetic diamond samples were exposed to laser beams of different energies, wavelengths, and pulse durations. The effects of this exposure were characterized using optical microscopy, scanning electron microscopy, and atomic force microscopy. The threshold ablation energy density for 266 nm radiation with {approx} 30 ps pulse duration was measured to be {approx} 14 J/cm{sup 2}. The threshold for {approx} 10 ns pulses at the same wavelength was similar, but the ablated area displayed larger surface damage. The surface damage and the threshold energy increase significantly for 532 and 1064 nm radiations. Ablation performed using 213 nm radiation produced the most uniform surface. Changes in the ablated surface are presented in detail.

43 PARTICLE ACCELERATORS↗

Drift tube soft-landing for the production and characterization of materials: Applied to Cu clusters

We have recently developed a soft-landing (SL) instrument that is capable of depositing ions onto substrates for preparative and developmental research of new materials using a laser ablation source. This instrument was designed with a custom drift tube and a split-ring ion optic for the isolation of selected ions. The drift tube allows for the separation and thermalization of ions formed after laser ablation through collisions with an inert bath gas. These collisions allow the ions to be landed at energies below 1 eV onto substrates. The split-ring ion optic is capable of directing ions toward the detector or a landing substrate for selected components. Experiments will be shown ablating Cu using an Nd:YAG (1064 and 532 nm) for cluster formation and landing onto a muscovite (mica) surface. The laser ablation of Cu in 8 Torr of He gas gives a spectrum that contains multiple peaks corresponding to Cu{sub n}, Cu{sub n}O{sub m} clusters, and their corresponding isomers. Atomic force microscopy and drift tube measurements were performed to characterize the performance characteristics of the instrument.

36 MATERIALS SCIENCE↗

In Depth Analysis of AVCOAT TPS Response to a Reentry Flow

Modeling of the high altitude portion of reentry vehicle trajectories with DSMC or statistical BGK solvers requires accurate evaluation of the boundary conditions at the ablating TPS surface. Presented in this article is a model which takes into account the complex ablation physics including the production of pyrolysis gases, and chemistry at the TPS surface. Since the ablation process is time dependent the modeling of the material response to the high energy reentry flow starts with the solution of the rarefied flow over the vehicle and then loosely couples with the material response. The objective of the present work is to carry out conjugate thermal analysis by weakly coupling a flow solver to a material thermal response model. The latter model solves the one dimensional heat conduction equation accounting for the pyrolysis process that takes place in the reaction zone of an ablative thermal protection system (TPS) material. An estimate of the temperature range within which the pyrolysis reaction (decomposition and volatilization) takes place is obtained from Ref. [1]. The pyrolysis reaction results in the formation of char and the release of gases through the porous charred material. These gases remove additional amount of heat as they pass through the material, thus cooling the material (the process known as transpiration cooling). In the present work, we incorporate the transpiration cooling model in the material thermal response code in addition to the pyrolysis model. The flow in the boundary layer and in the vicinity of the TPS material is in the transitional flow regime. Therefore, we use a previously validated statistical BGK method to model the flow physics in the vicinity of the micro-cracks, since the BGK method allows simulations of flow at pressures higher than can be computed using DSMC.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗