Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “57”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

Axion searches with the EDELWEISS-II experiment

We present new constraints on the couplings of axions and more generic axion-like particles using data from the EDELWEISS-II experiment. The EDELWEISS experiment, located at the Underground Laboratory of Modane, primarily aims at the direct detection of WIMPs using germanium bolometers. It is also sensitive to the low-energy electron recoils that would be induced by solar or dark matter axions. Using a total exposure of up to 448 kg.d, we searched for axion-induced electron recoils down to 2.5 keV within four scenarios involving different hypotheses on the origin and couplings of axions. We set a 95 % CL limit on the coupling to photons g{sub Aγ} < 2.15 × 10{sup −9} GeV{sup −1} in a mass range not fully covered by axion helioscopes. We also constrain the coupling to electrons, g{sub Ae} < 2.59 × 10{sup −11}, similar to the more indirect solar neutrino bound. Finally we place a limit on g{sub Ae} × g{sub AN}{sup eff} < 4.82 × 10{sup −17}, where g{sub AN}{sup eff} is the effective axion-nucleon coupling for {sup 57}Fe. Combining these results we fully exclude the mass range 0.92 eV < m{sub A} < 80 keV for DFSZ axions and 5.78 eV < m{sub A} < 40 keV for KSVZ axions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

RECONCILING THE INFRARED CATASTROPHE AND OBSERVATIONS OF SN 2011fe

The observational effects of the “Infrared Catastrophe” are discussed in view of the very late observations of the Type Ia SN 2011fe. Our model spectra at 1000 days take non-local radiative transfer into account and find that this has a crucial impact on the spectral formation. Although rapid cooling of the ejecta to a few 100 K occurs also in these models, the late-time optical/NIR flux is brighter by 1–2 mag due to redistribution of UV emissivity, resulting from non-thermal excitation and ionization. This effect brings models into better agreement with late-time observations of SN 2011fe, and other SNe Ia, and offers a solution to the long-standing discrepancy between models and observations. The models show that spectral formation shifts from Fe ii and Fe iii at 300 days to Fe i at 1000 days, which explains the apparent wavelength shifts seen in SN 2011fe. We discuss the effects of time dependence and energy input from {sup 57}Co, finding both to be important at 1000 days.

79 ASTRONOMY AND ASTROPHYSICS↗

Microscopic calculation of symmetry projected nuclear level densities

We present a quantum Monte Carlo method with exact projection on parity and angular momentum that is free of a sign problem for seniority-conserving nuclear interactions. This technique allows the microscopic calculation of angular momentum and parity-projected nuclear level densities. We present results for the {sup 55}Fe, {sup 56}Fe, and {sup 57}Fe isotopes. Signatures of the pairing phase transition are observed in the angular momentum distribution of the nuclear level density.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

g factor of the first excited state in {sup 56}Fe and implications for transient-field calibration in the Fe region

The transient-field technique has been used to measure the g factor of the 2{sub 1}{sup +} state in {sup 56}Fe relative to the independently determined g factor of the first 5/2{sup -} state in {sup 57}Fe. The new result for {sup 56}Fe agrees with previous measurements but is more precise. Implications for calibrating the transient field and g-factor measurements in the fp region are discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Production of very neutron-rich nuclei with a {sup 76}Ge beam

Production cross sections for neutron-rich nuclei from the fragmentation of a {sup 76}Ge beam at 132 MeV/u were measured. The longitudinal momentum distributions of 34 neutron-rich isotopes of elements 13{<=}Z{<=}27 were scanned using a novel experimental approach of varying the target thickness. Production cross sections with beryllium and tungsten targets were determined for a large number of nuclei, including 15 isotopes first observed in this work. These are the most neutron-rich nuclides of the elements 17{<=}Z{<=}25 ({sup 50}Cl, {sup 53}Ar, {sup 55,56}K, {sup 57,58}Ca, {sup 59,60,61}Sc, {sup 62,63}Ti, {sup 65,66}V, {sup 68}Cr, and {sup 70}Mn). A one-body Q{sub g} systematics is used to describe the production cross sections based on thermal evaporation from excited prefragments. Some of the fragments near {sup 58}Ca show anomalously large production cross sections.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fast-Neutron Activation of Long-Lived Isotopes in Enriched Ge

We measured the production of 57Co, 54Mn, 68Ge, 65Zn, and 60Co in an sample of Ge enriched in isotope 76 due to high-energy neutron interactions. These isotopes are critical in understanding background in Ge detectors used for double-beta decay experiments. These isotopes are produced by cosmogenic-neutron interactions in the detectors while they reside on the Earth's surface. We compared the measured production to that predicted by cross-section calculations based on CEM03.02. The cross section calculations over-predict our measurements by approximately a factor of 2-3 depending on isotope. We then use the measured cosmic-ray neutron ux and our results to predict the cosmogenic production rate with an accuracy near 15%.

Environmental Molecular Sciences Laboratory↗

Potential for large germanium detector arrays for solar-axion searches utilizing the axio-electric effect for detection

The sensitivities of large arrays of low-background germanium detectors for solar-axion, or axionlike particle, searches are investigated in the context of several coupling scenarios. A search was made for the 14.4-keV axion branch from the M1 transition in the thermally excited {sup 57}Fe in the solar core in 80 kg d of data from the International Germanium Experiment (IGEX) Dark Matter experiment. In one scenario, the direct couplings of axions to hadrons and to electrons were assumed to be in the range of the Peccei-Quinn scale 3x10{sup 5}{<=}f{sub PQ}{<=}7x10{sup 5} GeV. This scenario is excluded by the IGEX data. In a second case, at the same Peccei-Quinn scale, coupling to photons and to electrons is suppressed. The IGEX data partially exclude this scenario depending on the degree of suppression. In the third case, the Peccei-Quinn scale for all couplings is assumed to be in the range 3x10{sup 6}{<=}f{sub PQ}{<=}7x10{sup 6} GeV. Detection rates in Ge for all three scenarios are presented for several detector arrays.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Evidence for a Change in the Nuclear Mass Surface with the Discovery of the Most Neutron-Rich Nuclei with 17{<=}Z{<=}25

The results of measurements of the production of neutron-rich nuclei by the fragmentation of a {sup 76}Ge beam are presented. The cross sections were measured for a large range of nuclei including 15 new isotopes that are the most neutron-rich nuclides of the elements chlorine to manganese ({sup 50}Cl, {sup 53}Ar, {sup 55,56}K, {sup 57,58}Ca, {sup 59,60,61}Sc, {sup 62,63}Ti, {sup 65,66}V, {sup 68}Cr, {sup 70}Mn). The enhanced cross sections of several new nuclei relative to a simple thermal evaporation framework, previously shown to describe similar production cross sections, indicates that nuclei in the region around {sup 62}Ti might be more stable than predicted by current mass models and could be an indication of a new island of inversion similar to that centered on {sup 31}Na.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Sound velocities of compressed Fe{sup 3}c from simultaneous synchrotron x-ray diffraction and nuclear resonant scattering measurements.

The applications of nuclear resonant scattering in laser-heated diamond anvil cells have provided an important probe for the magnetic and vibrational properties of {sup 57}Fe-bearing materials under high pressure and high temperature. Synchrotron X-ray diffraction is one of the most powerful tools for studying phase stability and equation of state over a wide range of pressure and temperature conditions. Recently an experimental capability has been developed for simultaneous nuclear resonant scattering and X-ray diffraction measurements using synchrotron radiation. Here the application of this method to determine the sound velocities of compressed Fe{sub 3}C is shown. The X-ray diffraction measurements allow detection of microscale impurities, phase transitions and chemical reactions upon compression or heating. They also provide information on sample pressure, grain size distribution and unit cell volume. By combining the Debye velocity extracted from the nuclear resonant inelastic X-ray scattering measurements and the structure, density and elasticity data from the X-ray diffraction measurements simultaneously obtained, more accurate sound velocity data can be derived. Our results on few-crystal and powder samples indicate strong anisotropy in the sound velocities of Fe{sub 3}C under ambient conditions.

43 PARTICLE ACCELERATORS↗

Long term activation in a 15 MeV radiotherapy accelerator

The high energy electrons produced by linear accelerators can generate several radioisotopes by means of photonuclear reactions. The activity produced in the head of a 15 MV Mevatron Siemens 77 medical linear accelerator was measured by high resolution gamma-ray spectrometry, during its decommissioning 1 year after the last clinical use. The activity of {sup 54}Mn, {sup 57}Co, {sup 60}Co, {sup 181}W, and {sup 65}Zn was measured while the activity of other radioisotopes which emit soft {beta} or {gamma} rays such as {sup 59}Ni, {sup 63}Ni, and {sup 55}Fe was inferred by appropriate scaling factors. The number of pieces requiring particular care is limited, their mass does not exceed some tens of kilograms, and their volume is of the order of some thousands of cm{sup 3}. Moreover, these materials are metals and the emitted radiation can be easily shielded, so that storage should not create particular problems.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Modeling the performance of a photon counting x-ray detector for CT: Energy response and pulse pileup effects

Purpose: Recently, photon counting x-ray detectors (PCXDs) with energy discrimination capabilities have been developed for potential use in clinical computed tomography (CT) scanners. These PCXDs have great potential to improve the quality of CT images due to the absence of electronic noise and weights applied to the counts and the additional spectral information. With high count rates encountered in clinical CT, however, coincident photons are recorded as one event with a higher or lower energy due to the finite speed of the PCXD. This phenomenon is called a ''pulse pileup event'' and results in both a loss of counts (called ''deadtime losses'') and distortion of the recorded energy spectrum. Even though the performance of PCXDs is being improved, it is essential to develop algorithmic methods based on accurate models of the properties of detectors to compensate for these effects. To date, only one PCXD (model DXMCT-1, DxRay, Inc., Northridge, CA) has been used for clinical CT studies. The aim of that study was to evaluate the agreement between data measured by DXMCT-1 and those predicted by analytical models for the energy response, the deadtime losses, and the distorted recorded spectrum caused by pulse pileup effects. Methods: An energy calibration was performed using {sup 99m}Tc (140 keV), {sup 57}Co (122 keV), and an x-ray beam obtained with four x-ray tube voltages (35, 50, 65, and 80 kVp). The DXMCT-1 was placed 150 mm from the x-ray focal spot; the count rates and the spectra were recorded at various tube current values from 10 to 500 {mu}A for a tube voltage of 80 kVp. Using these measurements, for each pulse height comparator we estimated three parameters describing the photon energy-pulse height curve, the detector deadtime {tau}, a coefficient k that relates the x-ray tube current I to an incident count rate a by a=kxI, and the incident spectrum. The mean pulse shape of all comparators was acquired in a separate study and was used in the model to estimate the distorted recorded spectrum. The agreement between data measured by the DXMCT-1 and those predicted by the models was quantified by the coefficient of variation (COV), i.e., the root mean square difference divided by the mean of the measurement. Results: Photon energy versus pulse height curves calculated with an analytical model and those measured using the DXMCT-1 were in agreement within 0.2% in terms of the COV. The COV between the output count rates measured and those predicted by analytical models was 2.5% for deadtime losses of up to 60%. The COVs between spectra measured and those predicted by the detector model were within 3.7%-7.2% with deadtime losses of 19%-46%. Conclusions: It has been demonstrated that the performance of the DXMCT-1 agreed exceptionally well with the analytical models regarding the energy response, the count rate, and the recorded spectrum with pulse pileup effects. These models will be useful in developing methods to compensate for these effects in PCXD-based clinical CT systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Larmor procession reflectometry for studying multilayers

A new experimental method (angular encoding) based on the combination of reflectometry and neutron spin-echo methods, which makes it possible to use widely collimated neutron beams and provides an angular resolution of about 0.01 Degree-Sign , has been proposed. It was used to study magnetic thin films. In particular, the effect of Larmor pseudoprecession of neutron polarization upon reflection from a {sup 57}Fe film with a thickness of about 100 nm was investigated, and it was shown that this method allows one to determine the absolute magnetization direction; this cannot be done using conventional reflectometry.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Multilevel relaxation model for describing the Moessbauer spectra of nanoparticles in a magnetic field

A theory is developed for the Moessbauer absorption spectra of an ensemble of single-domain particles in a magnetic field. This theory is based on the generalization of a relaxation model with a quantummechanical description of the stationary states of a particle and on the formalism of Liouville operators for describing the hyperfine interaction for a hyperfine field changing in both the magnitude and direction for various stationary states. The general scheme of calculating relaxation Moessbauer spectra in terms of a standard stochastic approach is substantially optimized using operations with block matrices and a unique tridiagonalization of high-rank non-Hermitian matrices with a simple nonorthogonal transformation in the calculation procedure. The resulting model can easily be implemented on a personal computer. It considers the physical mechanisms of formation of a hyperfine structure in a spectrum of nanoparticles in a real situation and self-consistently describes the qualitative features of the nontrivial evolution of spectra with the temperature and the magnetic-field direction and strength, which has been detected in {sup 57}Fe nucleus experiments performed on magnetic nanoparticles for half a century.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Experimental studies of the gamma resonances of long-lived nuclear isomers

Studying the gamma resonances of the long-lived nuclear isomers started at ITEP in the 1960s–1970s. The first experiments were conducted with silver isotopes. Its results did not contradict the existing theoretical ideas of large broadening of Mössbauer gamma lines via the interactions of nuclear magnetic moments. However, the data obtained in 11 experiments performed up until now with gamma sources made of silver metal doping by {sup 109}Cd showed that there is no large broadening of {sup 109m}Ag Mössbauer gamma line with energy of 88.03 keV, that is the theoretically predicted gamma line broadening by ∼10{sup 5} times is absent. The instrument of quite a new type—“gravitational gamma spectrometer”, designed at ITEP, allowed one to determine the form of {sup 109m}Ag gamma resonance, which proved to be ∼10{sup 8} times narrower than that of well known nuclide {sup 57}Fe. Some ideas are discussed as an attempt to explain this situation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Emission sensitization and mechanisms of electron-excitation migration in structures based on III-nitrides doped with rare-earth elements (Eu, Er, Sm)

The effect of doping with Eu, Er, and Sm rare-earth ions on the shape of the luminescence spectrum for heterostructures with GaN/In{sub x}Ga{sub 1-x}N (0.1 < x < 0.4) quantum wells and from p-GaN<Mg>/n-GaN and p-AlGaN/n-GaN junctions is investigated. The results of measurements of the electroluminescence of these structures correlate with the previous data on photoluminescence and Moessbauer spectroscopy. It is shown that it is the GaN 'yellow' (5000-6000 A) band that plays the important role in the excitation of intracenter states in the structures with several GaN/InGaN quantum wells doped with Eu and Sm. In this case, Eu is most likely the sensitizer for Sm. Additional introduction of 3d metal (Fe{sup 57}) in p-GaN<Mg>/n-GaN:Eu results in the realization of intracenter transitions in Eu{sup 3+}: {sup 5}D{sub 0} {sup {yields} 7}F{sub 1} (6006 A), {sup 5}D{sub 0} {sup {yields} 7}F{sub 2} (6195 A), {sup 5}D{sub 0} {sup {yields} 7}F{sub 3} (6627 A), and {sup 5}D{sub 1} {sup {yields} 7}F{sub 4} (6327 A) due to the occurrence of new, efficient channels of excitation transfer to intracenter states and in the effect of Fe on the local environment of rare-earth ions including due to the f-d hybridization enhancement.

36 MATERIALS SCIENCE↗

Neutron Cross section Covariances in the Resonance region: 50,53Cr, 54,57Fe and 60Ni

We evaluated covariances in the neutron resonance region for capture and elastic scattering cross sections on minor structural materials, {sup 50,53}Cr, {sup 54,57}Fe and {sup 60}Ni. Use was made of the recently developed covariance formalism based on kernel approximation along with data in the Atlas of Neutron Resonances. Our results of most interest for advanced fuel cycle applications, elastic scattering cross section uncertainties at energies around 100 keV, are on the level of about 7-10%.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Real breakthrough in detection of radioactive sources by portal monitors with plastic detectors and New Advanced Source Identification Algorithm (ASIA-New)

Radiation Portal Monitors (RPM) with plastic detectors represent the main instruments used for primary border (customs) radiation control. RPM are widely used because they are simple, reliable, relatively inexpensive and have a high sensitivity. However, experience using the RPM in various countries has revealed the systems have some grave shortcomings. There is a dramatic decrease of the probability of detection of radioactive sources under high suppression of the natural gamma background (radiation control of heavy cargoes, containers and, especially, trains). NORM (Naturally Occurring Radioactive Material) existing in objects under control trigger the so-called 'nuisance alarms', requiring a secondary inspection for source verification. At a number of sites, the rate of such alarms is so high it significantly complicates the work of customs and border officers. This paper presents a brief description of new variant of algorithm ASIA-New (New Advanced Source Identification Algorithm), which was developed by the Rapiscan company. It also demonstrates results of different tests and the capability of a new system to overcome the shortcomings stated above. New electronics and ASIA-New enables RPM to detect radioactive sources under a high background suppression (tested at 15-30%) and to verify the detected NORM (KCl) and the artificial isotopes (Co- 57, Ba-133 and other). New variant of ASIA is based on physical principles, a phenomenological approach and analysis of some important parameter changes during the vehicle passage through the monitor control area. Thanks to this capability main advantage of new system is that this system can be easily installed into any RPM with plastic detectors. Taking into account that more than 4000 RPM has been installed worldwide their upgrading by ASIA-New may significantly increase probability of detection and verification of radioactive sources even masked by NORM. This algorithm was tested for 1,395 passages of different transports (cars, trucks and trailers) without radioactive sources. It also was tested for 4,015 passages of these transports with radioactive sources of different activity (Co-57, Ba-133, Cs-137, Co-60, Ra-226, Th-232) and these sources masked by NORM (K-40) as well. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗