Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “tunable”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

Laser Absorption Spectroscopy Measurements of Post-Shock Non-Equilibrium Species in the NASA Ames Electric Arc Shock Tube

The NASA Ames Electric Arc Shock Tube (EAST) is a unique facility capable of generating high enthalpy, shock-heated impulse gas flows representative of the kinetic and radiative conditions encountered by atmospheric entry vehicles. The facility maintains a successful history with emission spectroscopy, providing measurements of absolute radiance upon which various validation studies are anchored. The central objective of this work is to develop a comprehensive tunable diode laser absorption spectroscopy (TDLAS) sensing capability to provide complementary experimental insights to existing emission techniques. More specifically, a fast-scanning TDLAS-based diagnostic targeting the cyano radical (CN) in the near-infrared(near-IR) near 926.6 nm is employed in mixtures of 2.2% CH4in N2by mole for a sweep of incident shock velocities ranging 3.0-5.5 km/s and fill pressures 0.3-1.15 Torr. Laser scan rates up to 500 kHz probe multiple absorption features to provide quantitative measurements of temperature and species number density profiles behind the incident shock. In all instances, the temperature trend is consistent between emission-inferred and TDLAS-inferred measurements. However, at the lower-velocity conditions, there is an appreciable offset between the Data Parallel Line Relaxation Code (DPLR) simulation and experimental measurements. A similar behavior is observed in number density profiles, with emission measurements providing inferences of the CN(B) and CN(A) state, while TDLAS measurements provide an additional inference of the CN(X) state. In the fast-scanned experiments, measurement inferred number densities suggest a much faster production of CN at early times than captured by the model. This discrepancy motivates ongoing, additional spectroscopic and kinetics CN experiments to resolve the accuracy of modeling assumptions.

Efaine Chang↗

Measurements of Temperature and Enthalpy in NASA Ames 60-MW Arcjet using Atomic Oxygen and Atomic Nitrogen Absorption

We report on measurements of temperature and enthalpy in the 60-MW Interaction Heating Facility (IHF) Arcjet at the NASA Ames Research Center. These quantities were measured at sub-second temporal resolution using tunable diode laser absorption spectroscopy, employing four Distributed Feedback (DFB) lasers to simultaneously probe the arcjet flow. Optical access was achieved through a specially-designed optical disk mounted in series with the modules of the arc heater in the add-air plenum of the column, which is positioned between the downstream electrodes and the nozzle. Gas at this measurement location serves as the reservoir condition for the ensuing supersonic expansion. Conditions in the reservoir are extreme, with temperatures between 5000-8000 K and pressures between 1-9 atm. Absorption from the 5S state of atomic oxygen at 777.2 nm and the 4P state of atomic nitrogen at 868.0 nm, two electronically-excited quantum states, formed the basis of the flow characterization measurements. Fiber-coupled laser light was pitched through the IHF via 1/8" ports in the optical disks, permitting optical access with minimal intrusion to the flow. Data was collected at 3 nominal conditions, a Low condition (1600 A, 2000 V, 0.13 kg/s), a Medium condition (3500 A, 5700 V, 0.61 kg/s), and a High condition (5900 A, 6800 V, 0.84 kg/s). Measurements suggest agreement within 1-2% between excited oxygen and excited nitrogen thermometry, indicating approximate thermal and chemical equilibration of the arcjet reservoir state, a result in keeping with long-standing assumptions of CFD modelling. Spatial gradients are found in the flow due to enthalpy loss to the facility walls, but the measured spatial non-uniformities are consistent with axi-symmetry. Measurements of specific enthalpy in the reservoir are also made utilizing excited oxygen and excited nitrogen absorption under the assumption of chemical equilibration.

Peter M. Finch↗

Phase-change Reconfigurable Optical WavEfront Synthesis System (PROWESS)

We report the design, fabrication, and testing of electrically tunable metasurface k-space filters based on the low-loss, high-contrast phase-change material GSST and a transparent Si electrode heating architecture. A 10x10 array of PCM elements integrated with Si heaters was fabricated via foundry processes, and used to actively control the crystallinity of a metasurface consisting of GSST nano antennae. By selectively varying the structural state of individual PCM elements, specific k-vectors of transmitted light can effectively be filtered out, resulting in improved imaging quality by reducing the scattered light that reaches a detector. Optimized doping profiles in the Si heaters allow for uniform, low power, reliable and repeatable switching of the GSST state. Compared to other k-space filters, this new architecture is completely transparent to the wavelength of interest and can be actively reconfigured in real time with high performance, low power consumption and a small footprint. The 10x10 array device is a proof-of-concept demonstration that can enable high-resolution arbitrary wavefront synthesis and correction in the future, with key applications in optical communications, beam steering, remote sensing, and adaptive optics.

phase change material↗

Examination of Mars2020 Shock-Layer Conditions Via Infrared Emission Spectroscopy of CO2

A new test series was performed in the Electric Arc Shock Tube (EAST) facility, with the aim of reproducing flight conditions encountered during the Mars2020 mission entry into Mars atmosphere. For this test series, the EAST facility was instrumented with two spectrometers for Optical Emission Spectroscopy (OES) measurements and three mid-infrared lasers for Tunable Diode Laser Absorption Spectroscopy (TDLAS). This study focuses on the spectrally and spatially resolved radiance measured with OES. Comparison with CEA/NEQAIR and DPLR/NEQAIR simulations were made. For velocity above 2.7 km/s, measurements are found to lie between the different tested kinetic models, within ± 10%. Below 2.7 km/s, the chemistry appears to be frozen and measured radiance profiles are typically 10% above CEA predictions. This difference is explained by shock deceleration effects. Finally, comparison between OES and TDLAS data are made and show a good agreement on the measured temperature and CO2 number density profiles using the two diagnostics, typically within 10 and 5%, respectively.

Augustin Tibère-Inglesse↗

Metal-Templated Design of Chemically Switchable Protein Assemblies with High-Affinity Coordination Sites

To mimic a hypothetical pathway for protein evolution, we previously tailored a monomeric protein (cyt cb562) for metal-mediated self-assembly, followed by re-design of the resulting oligomers for enhanced stability and metal-based functions. We show that a single hydrophobic mutation on the cyt cb562 surface drastically alters the outcome of metal-directed oligomerization to yield a new trimeric architecture, (TriCyt1)3. This nascent trimer was redesigned into second and third-generation variants (TriCyt2)3 and (TriCyt3)3 with increased structural stability and preorganization for metal coordination. The three TriCyt variants combined furnish a unique platform to 1) provide tunable coupling between protein quaternary structure and metal coordination, 2) enable the construction of metal/pH-switchable protein oligomerization motifs, and 3) generate a robust metal coordination site that can coordinate all mid-to-late first-row transition-metal ions with high affinity.

Albert Kakkis↗

Absorption Laser Differential Interferometry for Simultaneous Colinear Flow Property and Fluctuation Measurements

An absorption laser differential interferometer (A-LDI) was constructed and tested in an effort to simultaneously and colinearly measure flow properties (pressure, temperature, concentration) and flow fluctuations (changes in optical path length). Whereas typical LDI and focused LDI (FLDI) systems use fixed wavelength lasers as the light source (often either green at approximately 532 nm or red at approximately 630 nm), a tunable 760 nm diode laser was used to probe the A-band absorption spectrum of molecular oxygen. The A-LDI system was used to measure O2 absorption and flow fluctuations in a sub-atmospheric pressure-controlled test cell, with absorption profiles from direct absorption and wavelength modulation absorption matching simulated results, while simultaneously being sensitive to high frequency fluctuations from jets of either compressed air or 100% O2 from a gas bottle. The A-LDI system was also installed at the NASA Langley Research Center Probe Calibration Tunnel to assess the freestream flow state in a Mach 3.5 flow. LDI measurements of the freestream indicated increasing amplitudes of flow fluctuations with increasing stagnation pressure at a fixed stagnation temperature, while absorption results demonstrated sensitivity to freestream pressure changes.

Joshua M. Weisberger↗

Mars 2020 Perseverance Rover SHERLOC Instrument Isolation System

The NASA Jet Propulsion Laboratory (JPL) successfully landed the Mars 2020 Perseverance Rover at Jezero Crater on the Martian surface. Perseverance’s main mission objective is to cache Martian rock and regolith samples in hermetically sealed tubes to be brought back to Earth by future missions. To achieve this goal the rover is equipped with a 2-meter-long Robotic Arm (RA) which manipulates the Turret to interact with the surface. The Turret is comprised of science instruments and tools that enable surface sampling and science. The backbone of the Turret hardware is the Rotary Percussive Coring Drill. The science instruments, which are directly mounted to the structural housing of this drill, must be able to withstand not only the launch and entry, descent and landing (EDL) loads of the vehicle but also the dynamic percussive environment, induced by the drill throughout surface operations. This paper discusses the technical hardware design, development and testing of a vibration isolation system to protect the Scanning Habitable Environments with Raman and Luminescence for Organics and Chemicals (SHERLOC) Instrument from these dynamic environments. The hardware design aspect of this problem was limited by both size and mass constraints. The Turret is tightly configured and the physical space in which hardware can reside is restricted due to multiple axes of surface interaction points. Another driving requirement is the extreme range of thermal non-operational environment from -135C to +90C. This, in addition to SHERLOC being a heavier instrument than previously integrated on a turret, made the use of isolation systems employed on previous rover missions problematic. The final design incorporates custom wire mesh springs preloaded within titanium hexapod struts equipped with flexure ends. Custom versions of commercially available wire mesh springs were designed and tested. These custom springs differed in dimension, density and stiffness from the off the shelf options. The newly designed springs went through various stages of flight acceptance testing. Detailed physics-based modeling to understand what loads the isolation system would experience was used to define the test conditions for the springs and entire isolation subsystem. The testing program developed around this was extensive to fully characterize the isolation performance over cleanliness levels, temperature and life. Another major aspect of this work was developing a method of replicating the drill’s percussive environment for performance and life testing of Turret mounted hardware. Attaching the instrument to an operating drill for testing was not a viable option. A method of using a Highly Accelerated Life Test (HALT) table was developed and applied across the project as the most representative and tunable option to physically simulate this new environment. This method, along with launch environment random vibration testing, was used to build an entire dynamic qualification and flight hardware test program. The results of the design, modeling, testing and analysis of the SHERLOC Isolation System is described throughout the following paper.

Krafchak, Todd↗

Velocity and Temperature Measurements in High-speed Flows with Naturally Present Dust Particles Using Rayleigh and Mie Scattering

Dust particles and occasional moisture condensations are unavoidable reality of all wind tunnels. On the path to pursue a goal of velocity and temperature measurements in large transonic and supersonic wind tunnels we have created a tabletop, spectrally resolved, Rayleigh-Mie scattering setup around a small jet fed by ambient and lightly seeded air to determine the viability and accuracy of the technique. The other reality of a wind tunnel setup is the background scattering or the glare at laser frequency, which contaminates the Rayleigh-Mie scattered light. This is simulated by backgrounds with different reflectivity towards the collection optics. Light from a CW laser is delivered via an optical fiber and the scattered light is spectrally resolved using a stabilized Fabry-Perot interferometer, followed by imaging on an EMCCD camera. A model of the of the combined background glare, Mie scattering, and the Rayleigh spectrum was fitted to the camera image using maximum likelihood estimation. Since the background glare occurs at the known frequency of the incident light and the Mie scattering peak corresponds to the Doppler shift from the bulk velocity, both were easily identified, and provided a measure of flow velocity. Preliminary results show that the Rayleigh spectrum can also be resolved, which provides a measure of temperature. It is observed that a slight drift of the laser frequency during data collection affected fitting of the model function leading to larger error. A feedback loop-based stabilization system is on development to take advantage of slight tunability of the laser via a piezo-control. Preliminary results are presented in the abstract. More extensive data from a systematic survey will be presented in the final paper.

Rayleigh scattering↗

Carbon Dioxide Active Remote Sensing Using Pulsed 2-µm Lidar

A pulsed 2-µm Integrate Path Differential Absorption (IPDA) lidar was developed at NASA Langley Research Center for high-accuracy and high-precision measurements of atmospheric carbon dioxide (CO 2 ). The instrument targets the R30 CO 2 absorption line and implements high-energy tunable on-line transmitter and advanced HgCdTe avalanche photodiode receiver. During 2019 airborne validation campaign, the IPDA was tested over the ocean for retrieving the weighted-average column dry-air volume mixing ratio of CO 2 (XCO 2 ) from 4.5 km altitude. XCO 2 measurement resulted in 404.43 ± 1.23 ppm using 10 s average, as compared to 405.49 ppm from prediction models. This translates to 0.26% and 0.30% relative accuracy and precision, respectively. Performance models were updated to scale the IPDA technology assuming operation from space platform. Results present XCO 2 measurements using the instrument capabilities considering different target scenarios for Earth’s surface. This demonstrates the potential for the IPDA technique and technology to achieve sustained global CO 2 measurement.

Active Remote Sensing↗

Carbon Dioxide Active Remote Sensing Using Pulsed 2-µm Lidar

A pulsed 2-µm Integrate Path Differential Absorption (IPDA) lidar was developed at NASA Langley Research Center for high-accuracy and high-precision measurements of atmospheric carbon dioxide (CO 2 ). The instrument targets the R30 CO 2 absorption line and implements high-energy tunable on-line transmitter and advanced HgCdTe avalanche photodiode receiver. During 2019 airborne validation campaign, the IPDA was tested over the ocean for retrieving the weighted-average column dry-air volume mixing ratio of CO 2 (XCO 2 ) from 4.5 km altitude. XCO 2 measurement resulted in 404.43 ± 1.23 ppm using 10 s average, as compared to 405.49 ppm from prediction models. This translates to 0.26% and 0.30% relative accuracy and precision, respectively. Performance models were updated to scale the IPDA technology assuming operation from space platform. Results present XCO 2 measurements using the instrument capabilities considering different target scenarios for Earth’s surface. This demonstrates the potential for the IPDA technique and technology to achieve sustained global CO 2 measurement.

Active Remote Sensing↗

Applications of PLIF within Supersonic/Hypersonic Flows relevant to Space Technology and Exploration

We summarize two recent applications of planar laser-induced fluorescence using seeded nitric oxide (NO-PLIF) within two different large-scale facilities for space technology and exploration. The first measurement campaign described is the NO-PLIF measurements performed within the 31-in Mach 10 air tunnel at NASA Langley Research Center for flow visualization, velocity, and temperature measurements of the wake produced by a hypersonic blunt-body. PLIF within this wake-flow was performed to support the developments of HIAD (hypersonic inflatable aerodynamic decelerator) technology, including the recent LOFTID flight mission. The second campaign is the NO-PLIF measurements performed within a 20-ft vacuum chamber at the NASA Marshall Space Flight Center for flow visualization of a Mach 5 plume impinging on a flat plate under rarefied and continuum conditions. PLIF within this supersonic flow was performed to support future lunar and Martian lander missions by investigating the plume impingement behavior. While both of these measurement campaigns were performed using 10 Hz PLIF laser systems, current efforts include utilization of tunable high-repetition-rate lasers for NO-PLIF measurements up to kHz-MHz rates.

Planar laser-induced fluorescence↗

In-Orbit Selection of Cryocooler Drive Frequencies for XRISM/Resolve

The XRISM/Resolve instrument cooling system uses adiabatic demagnetization refrigerators (ADRs) to cool the detectors to 50 mK and two types of cryocoolers to reduce heat load on the He tank, Joule-Thomson and Stirling cryocoolers. Resolve was designed with tunable cryocooler frequencies so that any mechanical interference and its effect on performance could be minimized. Measurements at different cryocooler drive frequencies were used to quantify the interference and narrow the acceptable range of frequency options. For Resolve the choice of cryocooler drive frequencies dramatically influences the instrument performance. Poor choices have been shown to degrade ADR cooling power and degrade the spectroscopic performance of the instrument. However, good choices have been shown to be free of undesirable features, allowing the instrument to satisfy its performance requirements with significant margin. Thus, the choice of drive frequencies is a critical factor for overall instrument performance. The drive frequencies of the Joule-Thomson cooler operating near 52 Hz, and the Stirling coolers operating near 15 Hz were adjusted in three distinct scan sequences to efficiently narrow the candidate frequency options. The frequency choices were based on stability of the 50 mK control thermometer, changes in the ADR demagnetization rate, and changes in detector noise. Scans across the drive frequency range of each cryocooler were performed multiple times during ground testing. Surprisingly, the results were not repeatable across test campaigns and did not conform to any discernable trend, but they were repeatable when remeasured within a single cool-down cycle. The conclusion was that the good/bad drive frequencies changed during Dewar warmup/cooldown, and possibly after mechanical vibration tests. Therefore, the settings could not be finalized before launch, and scans during instrument commissioning were necessary. This paper describes the cryocooler frequency scan measurements and compares the results during instrument commissioning to those performed during ground tests.

Gary A. Sneiderman↗

Uncertainty Budget for Detector-Based Absolute Radiometric Calibration With GLAMR

The accuracy of the absolute radiometric calibration (RadCal) for remote sensing instruments is essential to their wide range of applications. The uncertainty associated to the traditional source-based RadCal method is assessed at a 2% (k=1) or higher level for radiance measurement. To further improve the accuracy to meet the demands of climate studies, a detector-based approach using tunable lasers as a light source has been devised. The Goddard Laser for Absolute Measurement of Radiance, known as the GLAMR system, is a notable example of the incorporation of such technology. Using transfer radiometers calibrated at NIST as calibration standards, the absolute spectral response (ASR) function of a remote sensing instrument is measured with its uncertainty traceable to the International System of Units. This paper presents a comprehensive uncertainty analysis of the detector-based absolute RadCal using the GLAMR system. It identifies and examines uncertainty sources during the GLAMR RadCal test, including those from the GLAMR system, the testing configuration, and data processing methodologies. Analysis is carried out to quantify the contribution of each source and emphasize the most influential factors. It is shown that the calibration uncertainty of GLAMR RadCal can be better than 0.3% (k=1) in the wavelength range of 350-950 nm and 0.6% (k=1) between 950-2300 nm, with the exception of regions with strong water absorption. In addition, recommendations are made to refine the calibration process to further reduce the uncertainty.

Zhipeng Wang↗

Accelerating Continuous Variable Coherent Ising Machines Via Momentum

The Coherent Ising Machine (CIM) is a non-conventional architecture that takes inspiration from physical annealing processes to solve Ising problems heuristically. Its dynamics are naturally continuous and described by a set of ordinary differential equations that have been proven to be useful for the optimization of continuous variables nonconvex quadratic optimization problems. The dynamics of such Continuous Variable CIMs (CV-CIM) encourage optimization via optical pulses whose amplitudes are determined by the negative gradient of the objective; however, standard gradient descent is known to be trapped by local minima and hampered by poor problem conditioning. In this work, we propose to modify the CV-CIM dynamics using more sophisticated pulse injections based on tried-and-true optimization techniques such as momentum and Adam. Through numerical experiments, we show that the momentum and Adam updates can significantly speed up the CV-CIM’s convergence and improve sample diversity over the original CV-CIM dynamics. We also find that the Adam-CV-CIM’s performance is more stable as a function of feedback strength, especially on poorly conditioned instances, resulting in an algorithm that is more robust, reliable, and easily tunable. More broadly, we identify the CIM dynamical framework as a fertile opportunity for exploring the intersection of classical optimization and modern analog computing.

Ising Model↗

An Extension of the Truncated Ingard-Myers Impedance Boundary Condition for High Mach Number Grazing Flows

The Ingard-Myers impedance boundary condition is widely recognized to be prone to hydrodynamic Kelvin-Helmholtz-type instability, primarily due to its use of a vortex sheet to model the flow at the boundary. Recently, a stabilized approximation of the Ingard-Myers condition, called the Truncated Ingard-Myers Impedance Boundary Condition (TIMIBC), has been introduced. This approximation offers a good representation of the Ingard-Myers condition for grazing flows characterized by low to mid subsonic Mach numbers. This paper explores an extension of the TIMIBC, referred to as TIMIBC-ext, designed for liners in grazing flows with high subsonic Mach numbers. The TIMIBC-ext introduces a tunable parameter and demonstrates that by judiciously selecting the parameter value, the accuracy of the TIMIBC can be improved for either upstream or downstream propagating waves in grazing flows with high subsonic Mach numbers. Consequently, the TIMIBC-ext represents an enhancement to the TIMIBC when the location of the source relative to the liner (upstream or downstream) is known. Time domain implementations of the TIMIBC-ext are also provided, employing a multipole expansion model for the impedance function. A numerical example is provided to assess the performance of the TIMIBC-ext, comparing computational results with measurements from a recent set of measurements in the NASA Langley Grazing Flow Impedance Tube.

time domain acoustic scattering↗

Microbial Pigments and Their Degradation Products as Biosignatures

Carotenoids are a class of vibrant biological pigments that have a characteristic chemical structure centered around a polyene core (Lu et al. 2018). Carotenoids and their derivatives are candidate biosignatures because they can persist in the terrestrial geologic record for up to 1.73 billion years (Vinnichenko et al. 2020), have specific structures that are likely the result of complex pathways, mediate the survival of many microorganisms in Mars and Ocean Worlds analog environments, and are detectable with multiple techniques, including Raman spectroscopy. In this project, we aim to investigate the detectability of carotenoid pigments with different spectroscopic methods to inform future instrument selection. We compare the spectra of five unaltered carotenoids, two model compounds, and carotenoid-forming archaeon with visible and deep UV Raman spectroscopy and UVVis absorption spectrophotometry. We then use one model pigment, beta-carotene, to evaluate the likelihood that unique spectral properties of carotenoids, or their refractory byproducts, would be preserved and detectable on a remote planetary surface by exposing it to simulated conditions for Mars. Sample Acquisition. Pigments betacarotene, lutein, zeaxanthin, astaxanthin, and lycopene were purchased from Sigma Aldrich. Halobacterium salinarum NRC-1 was acquired from Carlina Biological and grown in Halobacterium media. Mineral salts including sodium sulfate, sodium carbonate, and halite were used to form matrices in which the beta-carotene was embedded before exposure. Pigment-mineral mixes were at a 1:10 ratio in water. Analytical Techniques. Deep UV Raman data were collected on a custom laboratory mapping spectrometer called MOBIUS (Mineral and Organic Based Investigations using Ultraviolet Spectroscopy), which is an analog to the SHERLOC instrument on the Mars 2020 Perseverance rover (Bhartia et al. 2021). It features a 248.56 nm NeCu pulsed laser, liquid nitrogen-cooled detector, and tunable optical setup. Visible Raman data were collected using a Horiba Jobin Yvon LabRam HR spectrometer with a frequencydoubled Nd:YAG laser (532 nm) and a HeNe laser (633 nm). A VWR 6300 PC UV/Visible Spectrophotometer was used to collect absorption data for carotenoid solutions, model compounds, and solvents in UVpermissible capped cuvettes. Data were collected from 190-1100 nm at 1 nm increments. All spectral data were analyzed using Igor Pro 9 (Wavemetrics). Irradiation. We used a vacuum chamber equipped with a cryostat and a flood electron gun to simulate Martian surface temperatures, low pressures, and ionizing radiation (10keV, 10μA for 6h at 200K for our initial tests). The samples were prepared by drying the pigment-mineral mix onto polished metal tabs, then mounted on the cryostat for processing. Samples were then analyzed directly on the tabs after exposure. Results: In comparing the visible and deep UV Raman spectra of unaltered pigments, we found that they differed drastically. Carotenoids are often studied with visible Raman and typically have peaks at 1525 cm-1 and 1157 cm-1, due to the stretching of the C=C and C-C bonds in the polyene structure. However, in deep UV, the strongest feature is at ~1630 cm-1 and is broad, possibly indicating that multiple peaks are forming this feature. This stark difference is likely due to different preresonant enhancement effects. The UV-Vis results show that there is an absorption band in the deep UV <300 nm, which supports the hypothesis that the 248.6 nm excitation is interrogating another aspect of carotenoids than visible Raman. Our preliminary exposure tests indicated that pigments – even without minerals present - were largely unaltered in the applied conditions, with only a slight broadening in the primary polyene peaks apparent in the visible Raman data. Figure 1. A) Visible vs. deep UV Raman spectra of unaltered beta carotene. B) Schematic of exposure. Conclusions: Our results to date indicate that deep UV and visible Raman spectroscopy, both techniques with planetary mission heritage from Mars 2020 (Wiens et al. 2021, Bhartia et al. 2021), may be used in a complementary manner to observe carotenoids. In addition, we find that beta-carotene is largely resistant to our current exposure conditions, though there may be some amount of amorphization of the material which could cause the broadening of the peaks at 1525 and 1157 cm-1. As a next step, we aim to increase the dosage and duration of exposure to observe degradation of the parent pigment, possibly add UV as a factor via an Ar mini-arc UV lamp and use GC-MS to characterize possible degradation products.

pigments↗

In-Orbit Selection of Cryocooler Drive Frequencies for XRISM/Resolve

The XRISM/Resolve instrument cooling system uses adiabatic demagnetization refrigerators (ADRs) to cool the detectors to 50 mK and Joule-Thomson and Stirling cryocoolers to reduce heat load on the He tank supporting the ADRs. Resolve was designed with tunable cryocooler drive frequencies so that interference could be avoided. The cryocooler generated micro-vibration changes with drive frequency and that micro-vibration causes interference and degrades instrument performance. Poor drive frequency choices have been shown to dramatically impact ADR cooling power, temperature stability, detector noise, and degrading spectroscopic performance. However, some choices are free of these features, allowing the instrument to satisfy its performance requirements with significant margin. Thus, the choice of drive frequencies is critical to achieving peak instrument performance. The drive frequencies of the Joule-Thomson cooler, near 52 Hz, and the Stirling coolers, near 15 Hz, were adjusted in three scan sequences while measuring interference to narrow candidate frequency options. Choices were based on stability of the 50 mK control thermometer, changes in the ADR demagnetization rate, and changes in detector noise. These scans were performed routinely during ground testing. Surprisingly though, the results were not repeatable after the Dewar was warmed and re-cooled but were repeatable when remeasured during the same test campaign. Since the good/bad drive frequencies change during Dewar warmup/cooldown, and possibly after vibration events, the drive frequencies could not be finalized before launch. This paper describes the cryocooler frequency scan measurements and compares the results during instrument commissioning to those performed during ground tests.

XRISM↗