Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “time integrator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

CabanaPD

CabanaPD is a meshfree peridynamics application built with Cabana and Kokkos. Kokkos enables performance portability across hardware architectures and Cabana provides particle capabilities including multi-node MPI support. The main components of CabanaPD are particle initialization, neighbor list generation, force and energy computation, time integration, and multi-node particle communication. In addition, options for creating pre-cracked regions and particle boundary conditions are available. CabanaPD currently enables two common force models: prototype microelastic brittle (PMB) and linear peridynamic solid (LPS). For both of these models, versions with and without fracture as well as linearized model options are available. CabanaPD is designed to be extensible for addition of more complex force models, boundary conditions, etc.

Reeve, Sam↗

Searching for Dark Matter with Superconducting Qubits

Dark matter is an enduring mystery in our quest to understand the fundamental constituents of our universe. Low mass bosons, such the axion or hidden photon, are compelling dark matter candidates. We leverage their potential interactions with electromagnetic fields, whereby the dark matter (of unknown mass) on rare occasion converts into a single photon, to devise a method of detecting these candidates. Current dark matter searches operating at microwave frequencies use a resonant cavity to coherently accumulate the field sourced by the dark matter and a near standard quantum limited (SQL) linear amplifier to read out the cavity signal. To further increase sensitivity to the dark matter signal and enable future searches, sub-SQL detection techniques are required.In this thesis, I report the development of a novel microwave photon counting technique and a new exclusion limit on hidden photon dark matter. We operate a superconducting qubit to make repeated quantum non-demolition measurements of cavity photons and apply a hidden Markov model analysis to reduce the noise to 15.7 dB below the quantum limit, with overall detector performance limited by a residual background of real photons. With the present device, we perform a hidden photon search and constrain the kinetic mixing angle to less than 1.68 x 10-15 in a band around 6.011 GHz (24.86 micro-eV) with an integration time of 8.33 s. This demonstrated noise reduction technique enables future dark matter searches to be sped up by a factor of 1300. By coupling a qubit to an arbitrary quantum sensor, more general sub-SQL metrology is possible with the techniques presented in this work.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Fuel element concept for long life high power nuclear reactors

Nuclear reactor fuel elements have burnups that are an order of magnitude higher than can currently be achieved by conventional design practice. Elements have greater time integrated power producing capacity per unit volume. Element design concept capitalizes on known design principles and observed behavior of nuclear fuel.

Mcdonald, G. E.↗

Microwave dosimeter - A concept

Dosimeter determines time-integrated radiation dosage to which an individual is exposed. Integration is measured chemically in proportion to radiation detected. Wearer receives an exposure measurement representing an average of the dose over the entire body.

Bartlett, R. G.↗

Resonant diffusion in the presence of strong plasma turbulence

The diffusion equation which describes the evolution of the average one particle distribution function for an ensemble of strongly turbulent plasmas is derived. The diffusion tensor is a time integral of the autocorrelation tensor of the fluctuations as observed by particles moving along statistically distributed orbits. These orbits contain the effects of fluctuations and thus differ from those encountered in weak turbulence theory. The plasma trajectory equations are used to relate each to the diffusion tensor itself when the turbulence is electrostatic. The diffusion tensor is explicity evaluated for a strongly turbulent unmagnetized plasma.

Birmingham, T. J.↗

Auroral oval kinematics program

A computer program which determines the geographic location of the auroral oval for given universal time and level of geomagnetic activity was developed for use on the IBM 7094 computer. The program provides both printed output of geographic coordinates of auroral oval boundaries and polar plots of the auroral oval. In addition, there is available a time-integration option which indicates how long a given location is under the auroral oval during a specified period. A description is given of the program and its use.

Comfort, R. H.↗

Noncontacting device to indicate deflection of turbopump internal rotating parts

Phase 2 (development) which was concluded for the ultrasonic Doppler device and the light-pipe-reflectance device is reported. An ultrasonic Doppler breadboard system was assembled which accurately measured runout in the J-2 LOX pump impeller during operation. The transducer was mounted on the outside of the pump volute using a C-clamp. Vibration was measured by conducting the ultrasonic wave through the volute housing and through the fluid in the volute to the impeller surface. The impeller vibration was also measured accurately using the light-pipe probe mounted in an elastomeric-gland fitting in the pump case. A special epoxy resin developed for cryogenic applications was forced into the end of the fiber-optic probe to retain the fibers. Subsequently, the probe suffered no damage after simultaneous exposure to 2150 psi and 77 F. Preliminary flash X-radiographs were taken of the turbine wheel and the shaft-bearing-seal assembly, using a 2-megavolt X-ray unit. Reasonable resolution and contrast was obtained. A fast-neutron detector was fabricated and sensitivity was measured. The results demonstrated that the technique is feasible for integrated-time measurements requiring, perhaps, 240 revolutions to obtain sufficient exposure at 35,000 rpm. The experimental verification plans are included.

Hamilton, D. B.↗

Correlation of irradiation data using activation fluences and irradiation temperature.

Nil-ductility transition temperature data for A302-B ferritic steel were analyzed by using multiple regression. Four independent variables were used - i.e., specimen temperature during irradiation, and time-integrated specific activations (activation fluences) of fast-, intermediate-, and thermal-neutron detectors. The results of these analyses were predictive equations having the increase in transition temperature as the dependent variable. For a reference point, a similar analysis was also performed using the flux integral above 1 MeV and the irradiation temperature as independent variables. Also, the effect of excluding irradiation temperature from these analyses was studied. The results of the analyses showed that excellent correlation was achieved by using activation fluences and irradiation temperature as the independent variables. Irradiation temperature was found to account for from 29 to 46% of the data variability depending on the model used.

Lynch, J. H.↗

The silicon vidicon: Integration, storage and slow scan capability - Experimental observation of a secondary mode of operation.

Description of the performance of the silicon diode array vidicon - an imaging sensor which possesses wide spectral response, high quantum efficiency, and linear response. These characteristics, in addition to its inherent ruggedness, simplicity, and long-term stability and operating life make this device potentially of great usefulness for ground-base and spaceborne planetary and stellar imaging applications. However, integration and charged storage for periods greater than approximately five seconds are not possible at room temperature because of diode saturation from dark current buildup. Since dark current can be reduced by cooling, measurements were made in the range from -65 to 25 C. Results are presented on the extension of integration, storage, and slow scan capabilities achievable by cooling. Integration times in excess of 20 minutes were achieved at the lowest temperatures. The measured results are compared with results obtained with other types of sensors and the advantages of the silicon diode array vidicon for imaging applications are discussed.

Ando, K. J.↗

Extreme ultraviolet solar images televised in-flight with a rocket-borne SEC vidicon system.

A TV image of the entire sun while an importance 2N solar flare was in progress was recorded in the extreme ultraviolet (XUV) radiation band 171-630 A and was transmitted to ground from an Aerobee-150 rocket on Nov. 4, 1969 using S-band telemetry. The camera tube was a SEC vidicon, with its fiber optic faceplate coated with an XUV-to-visible conversion layer of p-quaterphenyl. The XUV passband was produced by three 1000-A thick aluminum filters in series together with the platinized reflecting surface of the off-axis paraboloid that imaged the sun. A number of images were recorded with integration times between 1/30 sec and 2 sec. Reconstruction of pictures was enhanced by combining several to reduce the noise.

Tousey, R.↗

A proposed lunar orbiting gravity gradiometer experiment.

Analysis of the gravity gradiometer developed by Forward and Bell (1970) suggest that an accuracy, in the range 0.1 to 0.5 EU can be expected in a lunar orbiter application. This accuracy will allow gradient anomalies associated with mascons to be mapped with 1% accuracy and should reveal a great deal of new information about the lunar gravity field. The proposed experiment calls for putting such a gradiometer into a closely circular polar orbit at an average height of about 30 km above the lunar surface. This orbit allows the entire lunar surface to be covered in fourteen days, the gradiometer to be checked twice per revolution and results in successive passes above the lunar surface being spaced at about the resolution limit of about 30 km set both by the satellite altitude and instrumental integration time.

Debra, D. B.↗

Correlation of irradiation data using activation fluences and irradiation temperature.

A new method of correlating radiation damage data is tested using actual measured data taken from the open literature. This method, the activation fluence method, was found to be as accurate as other contemporary models with which it was compared. The new method also has several advantages over the other methods. The method employs a new entity, the activation fluence (time-integrated specific activation rate), as the independent variables in a regression model. Temperature at which the irradiation takes place is also a variable. Although the method was tested for a specific type of damage (change in nil-ductility transition temperature for A302-B steel) it has no inherent restrictions and is limited only by the imagination of the user.

Lynch, J. H.↗

Resonant diffusion in the presence of strong plasma turbulence.

The diffusion equation which describes the evolution of the average one-particle distribution function for an ensemble of strongly turbulent plasmas is derived. The diffusion tensor is a time integral of the autocorrelation tensor of the fluctuations as observed by particles moving along statistically distributed orbits. These orbits contain the effects of fluctuations and thus differ from those encountered in weak turbulence theory. Two statistical orbit effects quadratic in the strength of the fluctuations affect the magnitude of the diffusion: (a) modification of the ensemble average orbits by the fluctuations, and (b) statistical dispersion in particle orbits about the average. The plasma trajectory equations are used to relate each to the diffusion tensor itself when the turbulence is electrostatic. The diffusion tensor is explicitly evaluated for a strongly turbulent unmagnetized plasma.

Birmingham, T. J.↗

A urine volume measurement system

An improved urine volume measurement system for use in the unusual environment of manned space flight is reported. The system utilizes a low time-constant thermal flowmeter. The time integral of the transient response of the flowmeter gives the urine volume during a void as it occurs. In addition, the two phase flows through the flowmeter present no problem. Developments of the thermal flowmeter and a verification of the predicted performance characteristics are summarized.

Poppendiek, H. F.↗

Large deflection elastic-plastic dynamic response of stiffened shells of revolution

The formulation and check out porblems for a computer code DYNAPLAS, which analyzes the large deflection elastic-plastic dynamic response of stiffened shells of revolution, are presented. The formulation for special discretization is by the finite element method with finite differences being used for the evaluation of the pseudo forces due to material and geometric nonlinearities. Time integration is by the Houbolt method. The stiffeners may be due to concentrated or distributed eccentric rings and spring supports at arbitrary angles around the circumference of the elements. Check out porblems include the comparison of solutions from DYNAPLAS with experimental and other computer solutions for rings, conical and cylindrical shells and a curved panel. A hypothetical submarine including stiffeners and missile tube is studied under a combination of hydrostatic and dynamically applied asymmetrical pressure loadings.

Stricklin, J. A.↗