Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “spatial”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

Experimental study of spatial nonuniformities in 100 MHz capacitively coupled plasma using optical probe

Plasma spatial nonuniformities in the 100 MHz rf driven capacitively coupled reactor used for reactive ion etching of 300 mm substrates were experimentally studied using a linear scanning optical emission spectroscopy probe. Radial profiles of plasma emission intensity were measured both in argon and fluorocarbon-containing gas mixtures in the pressure interval of 10-80 mTorr and the rf power range of 500-1250 W. It was demonstrated that the plasma emission profiles strongly depend on the working gas composition and pressure. The profiles have a bell-like shape at pressures about 10 mTorr for all gases. As the pressure increases, the profile shape becomes more complex with the central and peripheral peaks, and the amplitudes of the peaks strongly depend on the working gas composition. It is suggested that the emission profiles show plasma spatial nonuniformities that can influence the etching rate profiles obtained with such systems. According to the existing theoretical models, the most probable reasons for these plasma nonuniformities are charged particle radial diffusion at low pressures (about 10 mTorr), as well as the standing wave and skin and edge effects at higher pressures. Using the experimental emission profiles, the working conditions have been found that allow one to achieve the most uniform plasma for discharges in argon and fluorocarbon-containing gas mixtures.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Spatial scaling metrics of mask-induced induced line-edge roughness

Mask contributors to line-edge roughness (LER) have recently been shown to be an issue of concern for both the accuracy of current resist evaluation tests as well the ultimate LER requirements for the 22-nm production node. Problems arise from mask absorber LER as well as mask reflector or surface roughness leading to random phase variations in the reflected beam. Not only do these mask contributors effect to total measured LER in resist, but they also effect LER spatial characteristic such as the LER power spectral density and related descriptors of correlation length and roughness exponent. Noting that these characteristics are important in the understanding of LER, it is crucial to understand how mask effects impact these parameters. Moreover, understanding how these metrics respond to mask effects may lead to an experimental mechanism for experimentally evaluating the importance of mask contributors to LER. Here we use computer modeling to study the LER spatial metrics arising from mask effects. We further describe the effects of illumination conditions and defocus on the metrics and compare the results to those expected from intrinsic resist LER.

36 MATERIALS SCIENCE↗

Continuous production of nanostructured particles using spatial atomic layer deposition

In this paper, the authors demonstrate a novel spatial atomic layer deposition (ALD) process based on pneumatic transport of nanoparticle agglomerates. Nanoclusters of platinum (Pt) of ∼1 nm diameter are deposited onto titania (TiO{sub 2}) P25 nanoparticles resulting to a continuous production of an active photocatalyst (0.12–0.31 wt. % of Pt) at a rate of about 1 g min{sup −1}. Tuning the precursor injection velocity (10–40 m s{sup −1}) enhances the contact between the precursor and the pneumatically transported support flows. Decreasing the chemisorption temperature (from 250 to 100 °C) results in more uniform distribution of the Pt nanoclusters as it decreases the reaction rate as compared to the rate of diffusion into the nanoparticle agglomerates. Utilizing this photocatalyst in the oxidation reaction of Acid Blue 9 showed a factor of five increase of the photocatalytic activity compared to the native P25 nanoparticles. The use of spatial particle ALD can be further expanded to deposition of nanoclusters on porous, micron-sized particles and to the production of core–shell nanoparticles enabling the robust and scalable manufacturing of nanostructured powders for catalysis and other applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Programmable Beam Spatial Shaping System for the National Ignition Facility

A system of customized spatial light modulators has been installed onto the front end of the laser system at the National Ignition Facility (NIF). The devices are capable of shaping the beam profile at a low-fluence relay plane upstream of the amplifier chain. Their primary function is to introduce 'blocker' obscurations at programmed locations within the beam profile. These obscurations are positioned to shadow small, isolated flaws on downstream optical components that might otherwise limit the system operating energy. The modulators were designed to enable a drop-in retrofit of each of the 48 existing Pre Amplifier Modules (PAMs) without compromising their original performance specifications. This was accomplished by use of transmissive Optically Addressable Light Valves (OALV) based on a Bismuth Silicon Oxide photoconductive layer in series with a twisted nematic liquid crystal (LC) layer. These Programmable Spatial Shaper packages in combination with a flaw inspection system and optic registration strategy have provided a robust approach for extending the operational lifetime of high fluence laser optics on NIF.

42 ENGINEERING↗

Dose convolution filter: Incorporating spatial dose information into tissue response modeling

Purpose: A model is introduced to integrate biological factors such as cell migration and bystander effects into physical dose distributions, and to incorporate spatial dose information in plan analysis and optimization. Methods: The model consists of a dose convolution filter (DCF) with single parameter {sigma}. Tissue response is calculated by an existing NTCP model with DCF-applied dose distribution as input. The authors determined {sigma} of rat spinal cord from published data. The authors also simulated the GRID technique, in which an open field is collimated into many pencil beams. Results: After applying the DCF, the NTCP model successfully fits the rat spinal cord data with a predicted value of {sigma}=2.6{+-}0.5 mm, consistent with 2 mm migration distances of remyelinating cells. Moreover, it enables the appropriate prediction of a high relative seriality for spinal cord. The model also predicts the sparing of normal tissues by the GRID technique when the size of each pencil beam becomes comparable to {sigma}. Conclusions: The DCF model incorporates spatial dose information and offers an improved way to estimate tissue response from complex radiotherapy dose distributions. It does not alter the prediction of tissue response in large homogenous fields, but successfully predicts increased tissue tolerance in small or highly nonuniform fields.

61 RADIATION PROTECTION AND DOSIMETRY↗

A spatially encoded dose difference maximal intensity projection map for patient dose evaluation: A new first line patient quality assurance tool

Purpose: To develop a spatially encoded dose difference maximal intensity projection (DD-MIP) as an online patient dose evaluation tool for visualizing the dose differences between the planning dose and dose on the treatment day. Methods: Megavoltage cone-beam CT (MVCBCT) images acquired on the treatment day are used for generating the dose difference index. Each index is represented by different colors for underdose, acceptable, and overdose regions. A maximal intensity projection (MIP) algorithm is developed to compress all the information of an arbitrary 3D dose difference index into a 2D DD-MIP image. In such an algorithm, a distance transformation is generated based on the planning CT. Then, two new volumes representing the overdose and underdose regions of the dose difference index are encoded with the distance transformation map. The distance-encoded indices of each volume are normalized using the skin distance obtained on the planning CT. After that, two MIPs are generated based on the underdose and overdose volumes with green-to-blue and green-to-red lookup tables, respectively. Finally, the two MIPs are merged with an appropriate transparency level and rendered in planning CT images. Results: The spatially encoded DD-MIP was implemented in a dose-guided radiotherapy prototype and tested on 33 MVCBCT images from six patients. The user can easily establish the threshold for the overdose and underdose. A 3% difference between the treatment and planning dose was used as the threshold in the study; hence, the DD-MIP shows red or blue color for the dose difference >3% or {<=}3%, respectively. With such a method, the overdose and underdose regions can be visualized and distinguished without being overshadowed by superficial dose differences. Conclusions: A DD-MIP algorithm was developed that compresses information from 3D into a single or two orthogonal projections while hinting the user whether the dose difference is on the skin surface or deeper.

60 APPLIED LIFE SCIENCES↗

Spatial and dose–response analysis of fibrotic lung changes after stereotactic body radiation therapy

Purpose: Stereotactic body radiation therapy (SBRT) is becoming the standard of care for early stage nonoperable lung cancers. Accurate dose–response modeling is challenging for SBRT because of the decreased number of clinical toxicity events. As a surrogate for a clinical toxicity endpoint, studies have proposed to use radiographic changes in follow up computed tomography (CT) scans to evaluate lung SBRT normal tissue effects. The purpose of the current study was to use local fibrotic lung regions to spatially and dosimetrically evaluate lung changes in patients that underwent SBRT.Methods: Forty seven SBRT patients treated at our institution from 2003 to 2009 were used for the current study. Our patient cohort had a total of 148 follow up CT scans ranging from 3 to 48 months post-therapy. Post-treatment scans were binned into intervals of 3, 6, 12, 18, 24, 30, and 36 months after the completion of treatment. Deformable image registration was used to align the follow up CT scans with the pretreatment CT and dose distribution. Areas of visible fibrotic changes were contoured. The centroid of each gross tumor volume (GTV) and contoured fibrosis volume was calculated and the fibrosis volume location and movement (magnitude and direction) relative to the GTV and 30 Gy isodose centroid were analyzed. To perform a dose–response analysis, each voxel in the fibrosis volume was sorted into 10 Gy dose bins and the average CT number value for each dose bin was calculated. Dose–response curves were generated by plotting the CT number as a function of dose bin and time posttherapy.Results: Both fibrosis and GTV centroids were concentrated in the upper third of the lung. The average radial movement of fibrosis centroids relative to the GTV centroids was 2.6 cm with movement greater than 5 cm occurring in 11% of patients. Evaluating dose–response curves revealed an overall trend of increasing CT number as a function of dose. The authors observed a CT number plateau at doses ranging from 30 to 50 Gy for the 3, 6, and 12 months posttherapy time points. There was no evident plateau for the dose–response curves generated using data from the 18, 24, 30, and 36 months posttherapy time points.Conclusions: Regions of local fibrotic lung changes in patients that underwent SBRT were evaluated spatially and dosimetrically. The authors found that the average fibrosis movement was 2.6 cm with movement greater than 5 cm possible. Evaluating dose–response curves revealed an overall trend of increasing CT number as a function of dose. Furthermore, our dose–response data also suggest that one of the possible explanations of the CT number plateau effect may be the time posttherapy of the acquired data. Understanding normal tissue dose–response is important for reducing toxicity after SBRT, especially in cases where larger tumors are treated. The methods presented in the current work build on prior quantitative studies and further enhance the understanding of normal lung dose–response after SBRT.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-D-BRB-06: Treating Glioblastoma Multiforme (GBM) as a Chronic Disease: Implication of Temporal-Spatial Dose Fractionation Optimization Including Cancer Stem Cell Dynamics

Purpose: To explore the feasibility of improving GBM treatment outcome with temporal-spatial dose optimization of an ordinary differential equation (ODE) that models the differentiation and distinct radiosensitivity between cancer stem cells (CSC) and differentiated cancer cells (DCC). Methods: The ODE was formulated into a non-convex optimization problem with the objective to minimize remaining total cancer cells 500 days from the onset of radiotherapy when the total cancer cell number was 3.5×10{sup 7}, while maintaining normal tissue biological effective dose (BED) of 100Gy resulted from standard prescription of 2Gyx30. Assuming spatially separated CSC and DCC, optimization was also performed to explore the potential benefit from dose-painting the two compartments. Dose escalation to a sub-cell-population in the GTV was also examined assuming that a 2 cm margin around the GTV allows sufficient dose drop-off to 100Gy BED. The recurrence time was determined as the time at which the total cancer cell number regrows to 10{sup 9} cells. Results: The recurrence time with variable fractional doses administered once per week, bi-week and month for one year were found to be 615, 593 and 570 days, superior to the standard-prescription recurrence time of 418 days. The optimal dose-fraction size progression for both uniform and dose-painting to the tumor is low and relatively constant in the beginning and gradually increases to more aggressive fractions at end of the treatment course. Dose escalation to BED of 200Gy to the whole tumor alongside with protracted weekly treatment was found to further delay recurrence to 733 days. Dose-painting of 200 and 500Gy BED to CSC on a year-long weekly schedule further extended recurrence to 736 and 1076 days, respectively. Conclusion: GBM treatment outcome can possibly be improved with a chronic treatment approach. Further dose escalation to the entire tumor or CSC targeted killing is needed to achieve total tumor control. This work is supported by the NSF Graduate Research Fellowship (DGE-1144087)

60 APPLIED LIFE SCIENCES↗

Spatial fractionation of the dose using neon and heavier ions: A Monte Carlo study

Purpose: This work explores a new radiation therapy approach which might trigger a renewed use of neon and heavier ions to treat cancers. These ions were shown to be extremely efficient in radioresistant tumor killing. Unfortunately, the efficient region also extends into the normal tissue in front of the tumor. The strategy the authors propose is to profit from the well-established sparing effect of thin spatially fractionated beams, so that the impact on normal tissues might be minimized while a high tumor control is achieved. The main goal of this work is to provide a proof of concept of this new approach. With that aim, a dosimetric study was carried out as a first step to evaluate the interest of further explorations of this avenue. Methods: The GATE/GEANT4 v.6.1 Monte Carlo simulation platform was employed to simulate arrays of rectangular minibeams (700 μm × 2 cm) of four ions (Ne, Si, Ar, and Fe). The irradiations were performed with a 2 cm-long spread-out Bragg peak centered at 7 cm-depth. Dose distributions in a water phantom were scored considering two minibeams center-to-center distances: 1400 and 3500 μm. Peak and valley doses, peak-to-valley dose ratios (PVDRs), beam penumbras, and relative contribution of nuclear fragments and electromagnetic processes were assessed as figures of merit. In addition, the type and proportion of the secondary nuclear fragments were evaluated in both peak and valley regions. Results: Extremely high PVDR values (>100) and low valley doses were obtained. The higher the atomic number (Z) of the primary ion is, the lower the valleys and the narrower the penumbras. Although the yield of secondary nuclear products increases with Z, the actual dose being deposited by the secondary nuclear fragments in the valleys starts to be the dominant contribution at deeper points, helping in the sparing of proximal normal tissues. Additionally, a wider center-to-center distance leads to a minimized contribution of heavier secondary fragments in valleys. Conclusions: The computed dose distributions suggest that a spatial fractionation of the dose combined to the use of submillimetric field sizes might allow profiting from the high efficiency of neon and heavier ions for the treatment of radioresistant tumors, while preserving normal tissues. The authors’ results support the further exploration of this avenue. Next steps include the realization of biological experiment to confirm the shifting of normal tissue complication probability curves.

60 APPLIED LIFE SCIENCES↗

Characterization of scintillator-based detectors for few-ten-keV high-spatial-resolution x-ray imaging

Purpose: High-spatial-resolution x-ray imaging in the few-ten-keV range is becoming increasingly important in several applications, such as small-animal imaging and phase-contrast imaging. The detector properties critically influence the quality of such imaging. Here the authors present a quantitative comparison of scintillator-based detectors for this energy range and at high spatial frequencies. Methods: The authors determine the modulation transfer function, noise power spectrum (NPS), and detective quantum efficiency for Gadox, needle CsI, and structured CsI scintillators of different thicknesses and at different photon energies. An extended analysis of the NPS allows for direct measurements of the scintillator effective absorption efficiency and effective light yield as well as providing an alternative method to assess the underlying factors behind the detector properties. Results: There is a substantial difference in performance between the scintillators depending on the imaging task but in general, the CsI based scintillators perform better than the Gadox scintillators. At low energies (16 keV), a thin needle CsI scintillator has the best performance at all frequencies. At higher energies (28–38 keV), the thicker needle CsI scintillators and the structured CsI scintillator all have very good performance. The needle CsI scintillators have higher absorption efficiencies but the structured CsI scintillator has higher resolution. Conclusions: The choice of scintillator is greatly dependent on the imaging task. The presented comparison and methodology will assist the imaging scientist in optimizing their high-resolution few-ten-keV imaging system for best performance.

60 APPLIED LIFE SCIENCES↗

SU-F-T-513: Dosimetric Validation of Spatially Fractionated Radiotherapy Using Gel Dosimetry

Purpose: Spatially fractionated radiation therapy, also known as GRID therapy, is used to treat large solid tumors by irradiating the target to a single dose of 10–20Gy through spatially distributed beamlets. We have investigated the use of a 3D gel for dosimetric characterization of GRID therapy. Methods: GRID therapy is an external beam analog of volumetric brachytherapy, whereby we produce a distribution of hot and cold dose columns inside the tumor volume. Such distribution can be produced with a block or by using a checker-like pattern with MLC. We have studied both types of GRID delivery. A cube shaped acrylic phantom was filled with polymer gel and served as a 3D dosimeter. The phantom was scanned and the CT images were used to produce two plans in Pinnacle, one with the grid block and one with the MLC defined grid. A 6MV beam was used for the plan with a prescription of 1500cGy at dmax. The irradiated phantom was scanned in a 3T MRI scanner. Results: 3D dose maps were derived from the MR scans of the gel dosimeter and were found to be in good agreement with the predicted dose distribution from the RTP system. Gamma analysis showed a passing rate of 93% for 5% dose and 2mm DTA scoring criteria. Both relative and absolute dose profiles are in good agreement, except in the peripheral beamlets where the gel measured slightly higher dose, possibly because of the changing head scatter conditions that the RTP is not fully accounting for. Our results have also been benchmarked against ionization chamber measurements. Conclusion: We have investigated the use of a polymer gel for the 3D dosimetric characterization and evaluation of GRID therapy. Our results demonstrated that the planning system can predict fairly accurately the dose distribution for GRID type therapy.

60 APPLIED LIFE SCIENCES↗

Sci-Thur PM – Colourful Interactions: Highlights 01: Design to delivery of spatially fractionated mini-beam canine radiotherapy

Spatial fractionation of radiation using arrays of narrow parallel micro-planar beams (less than 1 mm), is a relatively new concept with many unknowns specifically within the underlying biology of cell death. A tungsten collimator has been designed to produce mini-beams with a Varian linear accelerator for translational animal research into the effectiveness of spatial fractionation mini-beam radiotherapy (MBRT). This work presents the treatment planning process and workflow for the application of MBRT treatments within a clinical study. For patient dose calculations, the MBRT collimator was incorporated into a Monte Carlo based treatment planning system called MMCTP. Treatment planning was split between Eclipse and MMCTP, as the field apertures were determined within Eclipse prior to being sent to MMCTP for dose calculations. The calculated plan was transferred back into Aria with updated MUs per field for patient treatment. Patients were positioned within a vac-lock bag lying prone with a bite block and a thermoplastic mask to immobilize the head. Prior to treatment, a delivery verification plan was created within MMCTP. DQA output measurements of the treatment fields agreed with the calculated dose to within 1.5%. We have presented a workflow for MBRT treatments that include the planning technique, dose calculation method, DQA process and data integration into a record and verify system. The clinical study following this workflow represent the first series of linac based MBRT patients and depending on the clinical outcome of the study, our technique could be applied to human MBRT treatments.

60 APPLIED LIFE SCIENCES↗

Single-colony MALDI mass spectrometry imaging reveals spatial differences in metabolite abundance between natural and cultured Trichodesmium morphotypes

Trichodesmium, a globally significant N 2 -fixing marine cyanobacterium, forms extensive surface blooms in nutrient-poor ocean regions. These blooms consist of a dynamic assemblage of Trichodesmium species that form distinct colony morphotypes and are inhabited by diverse microorganisms. Trichodesmium colony morphotypes vary in ecological niche, nutrient uptake, and organic molecule release, differentially impacting ocean carbon and nitrogen biogeochemical cycles. Here, we assessed the poorly studied spatial abundance of metabolites within and between three morphologically distinct Trichodesmium colonies collected from the Red Sea. We also compared these results with two morphotypes of the cultivable Trichodesmium strain IMS101. Using matrix-assisted laser desorption/ionization (MALDI) mass spectrometry imaging (MSI) coupled with liquid extraction surface analysis (LESA) tandem mass spectrometry (MS2), we identified and localized a wide range of small metabolites associated with single-colony Trichodesmium morphotypes. Our untargeted MALDI-MSI approach revealed 80 unique features (metabolites) shared between Trichodesmium morphotypes. Discrimination analysis showed spatial variations in 57 shared metabolites, accounting for 62% of the observed variation between morphotypes. The greatest variations in metabolite abundance were observed between the cultured morphotypes compared to the natural colony morphotypes, suggesting substantial differences in metabolite production between the cultivable strain IMS101 and the naturally occurring colony morphotypes that the cultivable strain is meant to represent. This study highlights the variations in metabolite abundance between natural and cultured Trichodesmium morphotypes and provides valuable insights into metabolites common to morphologically distinct Trichodesmium colonies, offering a foundation for future targeted metabolomic investigations.

59 BASIC BIOLOGICAL SCIENCES↗

Excitons in artificial quantum dots in the weak spatial confinement regime

The exciton states in individual quantum dots prepared by the selective interdiffusion method in CdTe/CdMgTe quantum wells are studied by the methods of steady-state optical spectroscopy. The annealing-induced diffusion of Mg atoms inward to the bulk of the quantum well, which is significantly enhanced under the SiO{sub 2} mask, leads to a modulation of the bandgap width in the plane of the well, with the minima of the potential being located in the mask aperture areas. A lateral potential that arises, whose height is in the range 30-270 meV and characteristic scale is about 100 nm, efficiently localizes carriers, which form quasi-zero-dimensional excitons in the weak spatial confinement regime. Detailed magnetooptical studies show that Coulomb correlations play a significant role in the formation of exciton states under such a regime, which, in particular, manifests itself in the localization of the wavefunction of carriers on scales that are considerably smaller than the scale of the lateral potential. The particular features of the interlevel splitting, of the biexciton binding energy, and of the diamagnetic shift are discussed. A strong dependence of the interlevel relaxation on the interlevel splitting (the phonon neck) indicates that alternative relaxation mechanisms in the quantum dots studied are weak. The excited states are populated according to the Pauli principle, which indicates that it is possible to apply the shell model of many-exciton states to quantum dots under the weak spatial confinement conditions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effect of spatial nonuniformity of heating on compression and burning of a thermonuclear target under direct multibeam irradiation by a megajoule laser pulse

Direct-drive fusion targets are considered at present as an alternative to targets of indirect compression at a laser energy level of about 2 MJ. In this approach, the symmetry of compression and ignition of thermonuclear fuel play the major role. We report on the results of theoretical investigation of compression and burning of spherical direct-drive targets in the conditions of spatial nonuniformity of heating associated with a shift of the target from the beam center of focusing and possible laser radiation energy disbalance in the beams. The investigation involves numerous calculations based on a complex of 1D and 2D codes RAPID, SEND (for determining the target illumination and the dynamics of absorption), DIANA, and NUT (1D and multidimensional hydrodynamics of compression and burning of targets). The target under investigation had the form of a two-layer shell (ablator made of inertial material CH and DT ice) filled with DT gas. We have determined the range of admissible variation of compression and combustion parameters of the target depending on the variation of the spatial nonuniformity of its heating by a multibeam laser system. It has been shown that low-mode (long-wavelength) perturbations deteriorate the characteristics of the central region due to less effective conversion of the kinetic energy of the target shell into the internal energy of the center. Local initiation of burning is also observed in off-center regions of the target in the case of substantial asymmetry of irradiation. In this case, burning is not spread over the entire volume of the DT fuel as a rule, which considerably reduces the thermonuclear yield as compared to that in the case of spherical symmetry and central ignition.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spatial string tension in N{sub f} = 2 lattice QCD at finite temperature

The spatial string tension across a crossover from the low-temperature phase to the high-temperature phase is computed in QCD with two flavors of nonperturbatively improved Wilson fermions at small lattice spacing a {approx} 0.12 fm. We find that in the low-temperature phase spatial string tension agrees well with zero-temperature string tension. Furthermore, it does not show increasing for temperatures up to T = 1.36T{sub pc}, the highest temperature considered. Our results agree with some theoretical predictions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Structure of the spatial periphery of the isotopes {sup 9,11}Li

The cross sections for the (t, p) reactions on the lithium isotopes {sup 9,11}Li were calculated within a theoretical approach based on employing integral equations of the four-body problem in the Alt—Grassberger-Sandhas formalism and the multiparticle shell model. This made it possible to determine the wave functions for the relative motion of various clusters and the nuclear core and to calculate, on their basis, the root-mean-square radii of nuclei of the isotopes {sup 9,11}Li and the spatial structure of their neutron periphery. It is shown that the {sup 9}Li nucleus has virtually no neutron halo. The {sup 11}Li nucleus is a Borromean halo nucleus. The two-neutron periphery of this nucleus manifests itself in both spatial configurations, a dineutron and a cigar one, the respective root-mean-square radii being large (about 6.5 to 6.9 fm)

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Binding energy of excitons formed from spatially separated electrons and holes in insulating quantum dots

It is found that the binding energy of the ground state of an exciton formed from an electron and a hole spatially separated from each other (the hole is moving within a quantum dot, and the electron is localized above the spherical (quantum dot)–(insulating matrix) interface) in a nanosystem containing insulating Al{sub 2}O{sub 3} quantum dots is substantially increased (by nearly two orders of magnitude) compared to the exciton binding energy in an Al{sub 2}O{sub 3} single crystal. It is established that, in the band gap of an Al{sub 2}O{sub 3} nanoparticle, a band of exciton states (formed from spatially separated electrons and holes) appears. It is shown that there exists the possibility of experimentally detecting the ground and excited exciton states in the band gap of Al{sub 2}O{sub 3} nanoparticles at room temperature from the absorption spectrum of the nanosystem.

36 MATERIALS SCIENCE↗