Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “pixel detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

AC Read-Out Circuits for Single Pixel Characterization of TES Microcalorimeters and Bolometers

SRON is developing Frequency Domain Multiplexing (FDM) for the read-out of transition edge sensor (TES) soft x-ray microcalorimeters for the XMS instrument of the International X-ray Observatory and far-infrared bolometers for the SAFARI instrument on the Japanese mission SPICA. In FDM the TESs are AC voltage biased at frequencies from 0.5 to 6 MHz in a superconducting LC resonant circuit and the signal is read-out by low noise and high dynamic range SQUIDs amplifiers. The TES works as an amplitude modulator. We report on several AC bias experiments performed on different detectors. In particular, we discuss the results on the characterization of Goddard Space Flight Center x-ray pixels and SRON bolometers. The paper focuses on the analysis of different read-out configurations developed to optimize the noise and the impedance matching between the detectors and the SQUID amplifier. A novel feedback network electronics has been developed to keep the SQUID in flux locked loop, when coupled to superconducting high Q circuits, and to optimally tune the resonant bias circuit. The achieved detector performances are discussed in view of the instrument requirement for the two space missions.

Gottardi, L.↗

Design and performance of the first IceAct demonstrator at the South Pole

Here in this paper we describe the first results of IceAct, a compact imaging air-Cherenkov telescope operating in coincidence with the IceCube Neutrino Observatory (IceCube) at the geographic South Pole. An array of IceAct telescopes (referred to as the IceAct project) is under consideration as part of the IceCube-Gen2 extension to IceCube. Surface detectors in general will be a powerful tool in IceCube-Gen2 for distinguishing astrophysical neutrinos from the dominant backgrounds of cosmic-ray induced atmospheric muons and neutrinos: the IceTop array is already in place as part of IceCube, but has a high energy threshold. Although the duty cycle will be lower for the IceAct telescopes than the present IceTop tanks, the IceAct telescopes may prove to be more effective at lowering the detection threshold for air showers. Additionally, small imaging air-Cherenkov telescopes in combination with IceTop, the deep IceCube detector or other future detector systems might improve measurements of the composition of the cosmic ray energy spectrum. In this paper we present measurements of a first 7-pixel imaging air Cherenkov telescope demonstrator, proving the capability of this technology to measure air showers at the South Pole in coincidence with IceTop and the deep IceCube detector.

47 OTHER INSTRUMENTATION↗

Noise power spectrum of the fixed pattern noise in digital radiography detectors

Purpose: The fixed pattern noise in radiography image detectors is caused by various sources. Multiple readout circuits with gate drivers and charge amplifiers are used to efficiently acquire the pixel voltage signals. However, the multiple circuits are not identical and thus yield nonuniform system gains. Nonuniform sensitivities are also produced from local variations in the charge collection elements. Furthermore, in phosphor-based detectors, the optical scattering at the top surface of the columnar CsI growth, the grain boundaries, and the disorder structure causes spatial sensitivity variations. These nonuniform gains or sensitivities cause fixed pattern noise and degrade the detector performance, even though the noise problem can be partially alleviated by using gain correction techniques. Hence, in order to develop good detectors, comparative analysis of the energy spectrum of the fixed pattern noise is important. Methods: In order to observe the energy spectrum of the fixed pattern noise, a normalized noise power spectrum (NNPS) of the fixed pattern noise is considered in this paper. Since the fixed pattern noise is mainly caused by the nonuniform gains, we call the spectrum the gain NNPS. We first asymptotically observe the gain NNPS and then formulate two relationships to calculate the gain NNPS based on a nonuniform-gain model. Since the gain NNPS values are quite low compared to the usual NNPS, measuring such a low NNPS value is difficult. By using the average of the uniform exposure images, a robust measuring method for the gain NNPS is proposed in this paper. Results: By using the proposed measuring method, the gain NNPS curves of several prototypes of general radiography and mammography detectors were measured to analyze their fixed pattern noise properties. We notice that a direct detector, which is based on the a-Se photoconductor, showed lower gain NNPS than the indirect-detector case, which is based on the CsI scintillator. By comparing the gain NNPS curves of the indirect detectors, we could analyze the scintillator properties depending on the techniques for the scintillator surface processing. Conclusions: A robust measuring method for the NNPS of the fixed pattern noise of a radiography detector is proposed in this paper. The method can measure a stable gain NNPS curve, even though the fixed pattern noise level is quite low. From the measured gain NNPS curves, we can compare and analyze the detector properties in terms of producing the fixed pattern noise.

60 APPLIED LIFE SCIENCES↗

Speckle imaging with the PAPA detector

A new 2-D photon-counting camera, the PAPA (precision analog photon address) detector has been built, tested, and used successfully for the acquisition of speckle imaging data. The camera has 512 x 512 pixels and operates at count rates of at least 200,000/sec. In this paper, technical details on the camera are presented and some of the laboratory and astronomical results are included which demonstrate the detector's capabilities.

Papaliolios, C.↗

Noise figure of amplified dispersive Fourier transformation

Amplified dispersive Fourier transformation (ADFT) is a powerful tool for fast real-time spectroscopy as it overcomes the limitations of traditional optical spectrometers. ADFT maps the spectrum of an optical pulse into a temporal waveform using group-velocity dispersion and simultaneously amplifies it in the optical domain. It greatly simplifies spectroscopy by replacing the diffraction grating and detector array in the conventional spectrometer with a dispersive fiber and single-pixel photodetector, enabling ultrafast real-time spectroscopic measurements. Following our earlier work on the theory of ADFT, here we study the effect of noise on ADFT. We derive the noise figure of ADFT and discuss its dependence on various parameters.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Discorpy : algorithms and software for camera calibration and correction

Camera or lens-based detector calibration is essential for spatial accuracy in applications like dimensional tomography, optical metrology, and computer vision. Many methods and software exist yet there is still a lack of approaches that achieve both high accuracy and robustness while being easy to use and capable of handling a wide range of distortions. Radial lens distortion is common in high-resolution X-ray detector optics used in parallel-beam tomography at synchrotrons. Achieving sub-pixel accuracy requires calibrating with an optical target image. Although methods for characterizing radial distortion are well established, acquired images often also include perspective distortion and optical center offset. Here, we present our approaches to individually characterize and correct both types of distortion using a single calibration image, implemented in the Discorpy software.

36 MATERIALS SCIENCE↗

SU-E-T-415: An Ionization Chamber Array with High Spatial Resolution for External Beam Radiotherapy

Purpose: To characterize an ionization chamber array technology with high spatial resolution and high charge collection efficiency for external beam radiotherapy. Methods: The prototype under test is a linear array of air vented ionization chambers developed by IBA Dosimetry, consisting of 80 pixels with 3.5mm spatial resolution and 4mm{sup 3} sensitive volume. The detector was characterized in a plastic phantom with {sup 60} Co radiation and MV X-rays from an ELEKTA Agility LINAC (with flattened and unflattened beam qualities). Bias voltage was varied in order to evaluate charge collection efficiency. A commercial array of ionization chambers (MatriXX Evolution, IBA Dosimetry) and an amorphous silicon flat panel in direct conversion configuration were used as references. Results: Repeatability (0.4%) and stability under continuous gamma irradiation (0.3%) are very good, in spite of low active volume and sensitivity (∼200pC/Gy). Charge collection efficiency is higher than 99% already at 150V with ∼2mGy dose per pulse, leading to a ±1.1% sensitivity change with dose per pulse in the range 0.09-2mGy (covering all flattened and unflattened applications). Measured dose profiles are in agreement with MatriXX for fields larger than 2×2cm{sup 2}, in which case the linear array offers a much better characterization of the penumbra region. Down to 1×1cm{sup 2}, measured profiles are in very good agreement with the flat panel. Conclusion: The array represents a valuable tool for the characterization of treatment fields in which high spatial resolution is required, together with the dosimetric performance of air vented ionization chambers. Such a technology would be particularly valuable in association with advanced treatment modalities such as rotational radiotherapy, stereotactic treatments (even with unflattened beam qualities) and proton therapy, due to the insensitivity of the chambers on dose per pulse. In the future, a two dimensional prototype based on this technology will be developed and tested. This research project has been supported by a Marie Curie Early Initial Training Network Fellowship of the European Community's Seventh Framework Programme under contract number (PITN-GA-2011-289198-.

07 ISOTOPE AND RADIATION SOURCES↗

Low-Jitter Clock Receivers for Fast Timing Applications

Precision timing is a key requirement for emerging 4D particle tracking, Positron Emission Tomography (PET), beam and fusion plasma diagnostics, and other systems. Time-to-Digital Converters (TDCs) are commonly used to provide digital estimates of the relative timing between events, but the jitter performance of a TDC can be no better than the performance of the circuits that acquire the pulses and deliver them to the TDC. Several clock receiver and distribution circuits were evaluated, and a differential amplifier with resistive loads driving a pseudo-differential clock distribution network, developed using design guidelines for radiation tolerance and cryogenic compatibility, was fabricated as part of three prototypes: an analog front-end testbed chip for high-precision timing pixel readout, a dedicated TDC evaluation chip, and a Low-Gain Avalanche Detector (LGAD) readout circuit. Based on TDC measurements of the prototypes, we infer that the jitter added by the clock receiver and distribution circuits is less than 2.25 ps-rms. This performance meets the requirements of many future precision timing systems. The clock receiver and on-chip pseudo-differential driver were fabricated in commercial 28-nm CMOS technology and occupy 2288 µm 2 .

47 OTHER INSTRUMENTATION↗

Breadboard stellar tracker system test report, volume 1

The performance of a star tracker equipped with a focal plane detector was evaluated. The CID board is an array of 256 x 256 pixels which are 20 x 20 micrometers in dimension. The tracker used for test was a breadboard tracker system developed by BASD. Unique acquisition and tracking algorithms are employed to enhance performance. A pattern recognition process is used to test for proper image spread function and to avoid false acquisition on noise. A very linear, high gain, interpixel transfer function is derived for interpolating star position. The lens used in the tracker has an EFL of 100 mm. The tracker has an FOV of 2.93 degrees resulting in a pixel angular subtense of 41.253 arc sec in each axis. The test procedure used for the program presented a star to the tracker in a circular pattern of positions; the pattern was formed by projecting a simulated star through a rotatable deviation wedge. Further tests determined readout noise, Noise Equivalent Displacement during track, and spatial noise during acquisition by taking related data and reducing it.

Kollodge, J. C.↗

The SOFIA/SAFIRE Far-Infrared Spectrometer: Highlighting Submillimeter Astrophysics and Technology

The Submillimeter and Far-InfraRed Experiment (SAFIRE) on the SOFIA airborne observatory is an imaging spectrometer for wavelengths between 28 microns and 440 microns. Our design is a dual-band long-slit grating spectrometer, which provides broadband (approx. 4000 km/s) observations in two lines simultaneously over a field of view roughly 10" wide by 320" long. The low backgrounds in spectroscopy require very sensitive detectors with noise equivalent powers of order 10(exp -18) W/square root of Hz. We are developing a kilopixel, filled detector array for SAFIRE in a 32 x 40 format. The detector consists of a transition edge sensor (TES) bolometer array, a per-pixel broadband absorbing backshort array, and a NIST SQUID multiplexer readout array. This general type of array has been used successfully in the GISMO instrument, so we extrapolate to the sensitivity needed for airborne spectroscopy. Much of the cryogenic, electronics, and software infrastructure for SAFIRE have been developed. I provide here an overview of the progress on SAFIRE.

Benford, Dominic J.↗

IXO/XMS Detector Trade-Off Study

This document presents the outcome of the detector trade-off for the XMS instrument on IXO. This trade-off is part of the Cryogenic instrument Phase-A study as proposed to ESA in the Declaration of Interest SRONXMS-PL-2009-003 dated June 6, 2009. The detector consists of two components: a core array for the highest spectral resolution and an outer array to increase the field of view substantially with modest increase in the number of read-out channels. Degraded resolution of the outer array in comparison with the core array is accepted in order to make this scheme possible. The two detector components may be a single unit or separate units. These arrays comprise pixels and the components that allow them to be arrayed. Each pixel comprises a thermometer, an absorber, and the thermal links between them and to the rest of the array. These links may be interfaces or distinct components. The array infrastructure comprises the mechanical structure of the array, the arrangement of the leads, and features added to improve the integrated thermal properties of the array in the focal-plane assembly.

Kilbourne, Caroline Anne↗

Dual waveband compact catadioptric imaging spectrometer

A catadioptric dual waveband imaging spectrometer that covers the visible through short-wave infrared, and the midwave infrared spectral regions, dispersing the visible through shortwave infrared with a zinc selenide grating and midwave infrared with a sapphire prism. The grating and prism are at the cold stop position, enabling the pupil to be split between them. The spectra for both wavebands are focused onto the relevant sections of a single dual waveband detector. Spatial keystone distortion is controlled to less than one tenth of a pixel over the full wavelength range, facilitating the matching of the spectra in the midwave infrared with the shorter wavelength region.

47 OTHER INSTRUMENTATION↗

Optimizing TinyTPC Test Stand for Low Energy Event Reconstruction

Introducing dopants into liquid argon offers a promising avenue to enhance the sensitivity and performance of LAr detectors such as DUNE. To explore this opportunity, we are optimizing and deploying the TinyTPC test stand, a compact time projection chamber with LArPix readout to study the effects of photosensitive dopants on the charge detected. TinyTPC enables comparative measurements of low-energy responses under various operational configurations and provides a platform to study the behavior of pixel readouts at low energy. We ensured system reliability through continuous current and voltage monitoring, modeling the detector's electrical behavior, and indirectly estimating total resistance under testing conditions. We ran the Blanche cryostat under various thresholds and gain configurations to evaluate their potential impact to low-energy event reconstruction and advancing R&D efforts for dopant integration in neutrino detectors

Van Loenen, Drew [Franciscan U. Steubenville]↗

A new paradigm in electron microscopy: Automated microstructure analysis utilizing a dynamic segmentation convolutional neutral network

Over the past half century, the transmission electron microscope enabled insight into the fundamental arrangements and structures of materials. State-of-the-art electron microscopes can acquire large image datasets across multiple imaging modalities. However, the manual annotation process for feature or defect quantification may not be feasible with the modern microscope. Convolutional neural networks emerged to characterize individual microstructural features from an image in a cost-effective, consistent manner. However, many of these neural network approaches rely on thousands to hundreds of thousands of manual annotations of each feature type across hundreds of images to train the network for adequate performance. This work focused on the development and application of a pixel-wise defect detection machine-learning dynamic segmentation convolutional neural network with associated automated acquisition and postprocessing to identify microstructural features rapidly and quantitatively from a small initial dataset incorporating multiple imaging modes. The approach was demonstrated for characterization of superalloy 718 from both single image acquisition on multiple detectors to in-situ evolution captured with a single detector on a standard desktop computer to demonstrate the low barrier to entry required for widespread adoption. Pixel-by-pixel class identification was excellent with strong identification of chemically distinct phases, structurally distinct phases, and defect structures, thus demonstrating the new paradigm of machine learning-assisted characterization.

36 MATERIALS SCIENCE↗

Astrometric Calibration of Array Detectors

The high level of spatial uniformity in modern CCDs and other array detectors makes them excellent devices for astrometric and navigational systems. However, at the level of accuracy envisioned by the more ambitious projects, current technology produces devices with significant pixel registration errors. This paper describes a technique fot measuring relative pixel positions to an accuracy approaching 0.001 pixel. The technique has been applied to WF/PC II CCDs whicha re shown to have 500 nm step-and-repeat errors.

array detectors CCDs navigational systems astromet↗

Ground Calibration of the Astro-H (Hitomi) Soft X-Ray Spectrometer

The Astro-H (Hitomi) Soft X-ray Spectrometer (SXS) was a pioneering imaging x-ray spectrometer with 5 eV energy resolution at 6 keV. The instrument used a microcalorimeter array at the focus of a high-throughput soft x-ray telescope to enable high-resolution non-dispersive spectroscopy in the soft x-ray waveband (0.3-12 keV). We present the suite of ground calibration measurements acquired from 2012-2015, including characterization of the detector system, anti-coincidence detector, optical blocking filters, and filter-wheel filters. The calibration of the 36-pixel silicon thermistor microcalorimeter array includes parameterizations of the energy gain scale and line spread function for each event grade over a range of instrument operating conditions, as well as quantum efficiency measurements. The x-ray transmission of the set of five Al/polyimide thin-film optical blocking filters mounted inside the SXS dewar has been modeled based on measurements at synchrotron beamlines, including with high spectral resolution at the C, N, O, and Al K-edges. In addition, we present the x-ray transmission of the dewar gate valve and of the filters mounted on the SXS filter wheel (external to the dewar), including beryllium, polyimide, and neutral density filters.

detectors↗

Determining Optimal Running Conditions for TinyTPC Detector

Liquid argon time projection chambers, (LArTPCs), are particle detectors used to collect ionization charge information from particle trajectories, facilitating detailed particle track analysis. They are currently used as particle detectors in major physics projects such as the deep underground neutrino experiment (DUNE), to detect and study the nature of the elusive neutrino particle. TinyTPC is a small scale LArTPC featuring a pixelated readout system (LArPix) that we will use to study liquid argon doping. We expect this doping to enhance the resolution of LAr detectors, especially for low energy particles below 10 MeV which would expand the capabilities of currently running experiments. Housed within a cryostat filled with liquid argon, the TinyTPC will rely on a high and a low voltage system to collect data. In preparation for deployment we found and resolved issues in the HV and LV systems and we determined optimal running conditions in a test vessel. This presentation will go over the detector commissioning process that enabled data taking with the TinyTPC.

Gonzalez, Rebecca↗