Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “methods: statistical”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

Deep neural networks for energy and position reconstruction in EXO-200

Here, we apply deep neural networks (DNN) to data from the EXO-200 experiment. In the studied cases, the DNN is able to reconstruct the relevant parameters—total energy and position—directly from raw digitized waveforms, with minimal exceptions. For the first time, the developed algorithms are evaluated on real detector calibration data. The accuracy of reconstruction either reaches or exceeds what was achieved by the conventional approaches developed by EXO-200 over the course of the experiment. Most existing DNN approaches to event reconstruction and classification in particle physics are trained on Monte Carlo simulated events. Such algorithms are inherently limited by the accuracy of the simulation. We describe a unique approach that, in an experiment such as EXO-200, allows to successfully perform certain reconstruction and analysis tasks by training the network on waveforms from experimental data, either reducing or eliminating the reliance on the Monte Carlo.

97 MATHEMATICS AND COMPUTING↗

Initial results on energy resolution of the NEXT-White detector

One of the major goals of the NEXT-White (NEW) detector is to demonstrate the energy resolution that an electroluminescent high pressure xenon TPC can achieve for high energy tracks. For this purpose, energy calibrations with 137Cs and 232Th sources have been carried out as a part of the long run taken with the detector during most of 2017. This paper describes the initial results obtained with those calibrations, showing excellent linearity and an energy resolution that extrapolates to approximately 1% FWHM at Q$_{\beta\beta}$.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of the ePix100a and the FastCCD Semiconductor Detectors for the European XFEL

Here, the European X-ray Free Electron Laser (EuXFEL) is a research facility providing spatially coherent X-ray flashes in the energy range from 0 . 25 keV to 25 keV of unprecedented brilliance and with unique time structure: X-ray pulses with a 4 . 5 MHz repetition rate arranged in trains with 2700 pulses every 100 ms. The facility operates three photon beamlines called SASE 1, SASE 2 and SASE 3. Each of the beamlines is hosting two scientific experiments. The SASE 1 beamline started its user operation in September 2017, followed by successful first lasing at the SASE 2 beamline in May 2018. Early user experiments are planned to start in 2019 at this beamline, while early user experiments for the SASE 3 beamline are scheduled for the end of 2018. The quality of the experimental data will gain substantial benefits from an accurate characterization and calibration of the X-ray detectors. Supplementing high repetition rate detectors at MHz speeds, slower detectors such as the ePix100a and the FastCCD will be operated at the train repetition rate of 10 Hz. These 2D silicon pixelized detectors use fast parallel column-wise readout implemented as a CCD or as a hybrid pixel detector. In the following, characterization and analysis approaches for the FastCCD and the ePix100a detectors are discussed and the performance of the detectors is evaluated using appropriate state-of-the-art analysis techniques.

47 OTHER INSTRUMENTATION↗

Parametrizing the detector response with neural networks

In high energy physics, characterizing the response of a detector to radiation is one of the most important and fundamental experimental tasks. In many cases, this task is accomplished by parameterizing summary statistics of the full detector response probability density. The parameterized detector response can then be used for calibration as well as for directly improving physics analysis sensitivity. This paper reports on how to parameterize summary statistics of the detector response using neural networks. Specifically, neural networks are powerful tools for incorporating multidimensional data and the loss function used during training determines which summary statistic is learned. One common summary statistic that has not been combined with deep learning (as far as the authors are aware) is the mode. A neural network-based approach to mode learning is proposed and empirically demonstrated in the context of high energy jet calibrations. Altogether, the neural network-based toolkit for detector response parameterization can enhance the utility of data collected at high energy physics experiments and beyond.

47 OTHER INSTRUMENTATION↗

Automated detector simulation and reconstruction parametrization using machine learning

Rapidly applying the effects of detector response to physics objects (e.g. electrons, muons, showers of particles) is essential in high energy physics. Presently available tools for the transformation from truth-level physics objects to reconstructed detector-level physics objects involve manually defining resolution functions. These resolution functions are typically derived in bins of variables that are correlated with the resolution (e.g. pseudorapidity and transverse momentum). This process is time consuming, requires manual updates when detector conditions change, and can miss important correlations. Machine learning offers a way to automate the process of building these truth-to-reconstructed object transformations and can capture complex correlation for any given set of input variables. Such machine learning algorithms, with sufficient optimization, could have a wide range of applications: improving phenomenological studies by using a better detector representation, allowing for more efficient production of Geant4 simulation by only simulating events within an interesting part of phase space, and studies on future experimental sensitivity to new physics.

47 OTHER INSTRUMENTATION↗

Fast inference of Boosted Decision Trees in FPGAs for particle physics

We describe the implementation of Boosted Decision Trees in the hls4ml library, which allows the translation of a trained model into FPGA firmware through an automated conversion process. Thanks to its fully on-chip implementation, hls4ml performs inference of Boosted Decision Tree models with extremely low latency. With a typical latency less than 100 ns, this solution is suitable for FPGA-based real-time processing, such as in the Level-1 Trigger system of a collider experiment. These developments open up prospects for physicists to deploy BDTs in FPGAs for identifying the origin of jets, better reconstructing the energies of muons, and enabling better selection of rare signal processes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Geant4Reweight: a framework for evaluating and propagating hadronic interaction uncertainties in Geant4

Geant4Reweight is an open-source C++ framework that allows users to weight tracks produced by the Geant4 particle transport Monte Carlo simulation according to hadron interaction cross section variations and estimate uncertainties in Geant4 interaction models by comparing the simulation’s hadron interaction cross section predictions to data. The ability to weight hadron transport as simulated by Geant4 is crucial to the propagation of systematic uncertainties related to secondary hadronic interactions in current and upcoming neutrino oscillation experiments, including MicroBooNE, NOvA, and DUNE, aswell as hadron test beam experiments such as ProtoDUNE. Here, we provide motivation for weighting hadron tracks in Geant4 in the context of systematic uncertainty propagation, a description of Geant4’s transport simulation technique, and a description of our weighting technique and fitting framework in the momentum range 0–10 GeV/c, which is typical for the hadrons produced by neutrino interactions in these experiments.

97 MATHEMATICS AND COMPUTING↗

Optical calibration of the SNO+ detector in the water phase with deployed sources

SNO+ is a large-scale liquid scintillator experiment with the primary goal of searching for neutrinoless double beta decay, and is located approximately 2 km underground in SNOLAB, Sudbury, Canada. The detector acquired data for two years as a pure water Cherenkov detector, starting in May 2017. During this period, the optical properties of the detector were measured in situ using a deployed light diffusing sphere, with the goal of improving the detector model and the energy response systematic uncertainties. The measured parameters included the water attenuation coefficients, effective attenuation coefficients for the acrylic vessel, and the angular response of the photomultiplier tubes and their surrounding light concentrators, all across different wavelengths. Finally, the calibrated detector model was validated using a deployed tagged gamma source, which showed a 0.6% variation in energy scale across the primary target volume.

47 OTHER INSTRUMENTATION↗

Single electron in a storage ring: a probe into the fundamental properties of synchrotron radiation and a powerful diagnostic tool

An experimental study of undulator radiation generated by a single electron was carried out at the Integrable Optics Test Accelerator (IOTA) storage ring at Fermilab. Photons were detected with a single-photon avalanche diode (SPAD) at an average rate of 20 kHz, corresponding to one detection every few hundred revolutions. Events were continuously recorded by a picosecond event timer for as long as 5 minutes at a time. The collected data were used to directly test the predictions of classical Poisson photostatistics. The study was motivated in part by a previous observation of sub-Poissonian statistics in a similar experiment with synchrotron radiation. In addition, we show that the time series of recorded events can be used to study the synchrotron motion of a single electron, yielding dynamical parameters such as the phase jitter of the radiofrequency cavity and the dependence of the synchrotron period on amplitude. Research plans for further experiments are also discussed.

47 OTHER INSTRUMENTATION↗

Muon track reconstruction in a segmented bolometric array using multi-objective optimization

Recent advances in segmented solid-state detector arrays for rare-event searches have allowed the technology to approach the ton-scale in detector mass and the scale of meters in size. Often focused around searches for neutrinoless double-beta decay or direct dark matter detection, such experiments also have the capability to search for exotic particles that leave track-like signatures across their volume. However, the segmented nature of such detector arrays often sets the spatial resolution and makes the problem of reconstructing track-like paths non-trivial. Here, in this paper, we present an algorithm that improves reconstruction of track-like events in segmented detectors using multi-objective optimization — a computational technique that optimizes more than one cost function at a time without specifying a quantitative weighting between them. Such a technique allows the reconstruction of tracks through a detector and the determination of path-lengths through individual elements. When combined with the reconstructed energy depositions in each element this allows for a calculation of the stopping power of track-like particles and opens the door to searches for particles with abnormal stopping power like monopoles or lightly-ionizing particles (LIPs). Results are presented which evaluate the precision of the reconstruction tools as they currently stand against Monte Carlo generated data. The algorithm is presented in the context of the CUORE experiment, but has applications to other segmented calorimeter detectors.

47 OTHER INSTRUMENTATION↗

FlameNEST: explicit profile likelihoods with the Noble Element Simulation Technique

We present FlameNEST, a framework providing explicit likelihood evaluations in noble element particle detectors using data-driven models from the Noble Element Simulation Technique. FlameNEST provides a way to perform statistical analyses on real data with no dependence on large, computationally expensive Monte Carlo simulations by evaluating the likelihood on an event-by-event basis using analytic probability elements convolved together in a single TensorFlow multiplication. Furthermore, this robust framework creates opportunities for simple inter-collaboration analyses which will be fundamental for the future of experimental dark matter physics.

47 OTHER INSTRUMENTATION↗

Calomplification — the power of generative calorimeter models

Motivated by the high computational costs of classical simulations, machine-learned generative models can be extremely useful in particle physics and elsewhere. They become especially attractive when surrogate models can efficiently learn the underlying distribution, such that a generated sample outperforms a training sample of limited size. This kind of GANplification has been observed for simple Gaussian models. We show the same effect for a physics simulation, specifically photon showers in an electromagnetic calorimeter.

47 OTHER INSTRUMENTATION↗

Characterisation of ion temperature and toroidal rotation on the ST40 tokamak

ST40 is a high field low-aspect ratio spherical tokamak built and operated by Tokamak Energy Ltd. Recent plasma operations were aimed at exploring operational scenarios to maximise the central plasma temperature and have culminated in the achievement of thermal ion temperatures of over 9 keV. Here this paper presents ion temperature and toroidal rotation measurements performed on ST40 during the 2021–22 campaign for a range of different scenarios. Several independent diagnostic systems are used, analysing their correlation and interpreting their differences using new diagnostic forward models.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Energy calibration of germanium detectors for the Majorana Demonstrator

The Majorana Demonstrator was a search for neutrinoless double-beta decay (0νββ) in the 76 Ge isotope. It was staged at the 4850-foot level of the Sanford Underground Research Facility (SURF) in Lead, SD. The experiment consisted of 58 germanium detectors housed in a low background shield and was calibrated once per week by deploying a 228 Th line source for 1 to 2 hours. The energy scale calibration determination for the detector array was automated using custom analysis tools. We describe the offline procedure for calibration of the Demonstrator germanium detectors, including the simultaneous fitting of multiple spectral peaks, estimation of energy scale uncertainties, and the automation of the calibration procedure.

47 OTHER INSTRUMENTATION↗

ALICE luminosity determination for Pb–Pb collisions at $\sqrt{s_{NN}}$ = 5.02 TeV

Luminosity determination within the ALICE experiment is based on the measurement, in van der Meer scans, of the cross sections for visible processes involving one or more detectors (visible cross sections). In 2015 and 2018, the Large Hadron Collider provided Pb–Pb collisions at a centre-of-mass energy per nucleon pair of $\sqrt{s_{NN}}$ = 5.02 TeV. Two visible cross sections, associated with particle detection in the Zero Degree Calorimeter (ZDC) and in the V0 detector, were measured in a van der Meer scan. This article describes the experimental set-up and the analysis procedure, and presents the measurement results. The analysis involves a comprehensive study of beam-related effects and an improved fitting procedure, compared to previous ALICE studies, for the extraction of the visible cross section. The resulting uncertainty of both the ZDC-based and the V0-based luminosity measurement for the full sample is 2.5%. The inelastic cross section for hadronic interactions in Pb–Pb collisions at $\sqrt{s_{NN}}$ = 5.02 TeV, obtained by efficiency correction of the V0-based visible cross section, was measured to be 7.67 ± 0.25 b, in agreement with predictions using the Glauber model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Comparison of point cloud and image-based models for calorimeter fast simulation

Score based generative models are a new class of generative models that have been shown to accurately generate high dimensional calorimeter datasets. Recent advances in generative models have used images with 3D voxels to represent and model complex calorimeter showers. Point clouds, however, are likely a more natural representation of calorimeter showers, particularly in calorimeters with high granularity. Furthermore, point clouds preserve all of the information of the original simulation, more naturally deal with sparse datasets, and can be implemented with more compact models and data files. In this work, two state-of-the-art score based models are trained on the same set of calorimeter simulation and directly compared.

47 OTHER INSTRUMENTATION↗

Photon classification with Gradient Boosted Trees at CLAS12

Dihadron semi-inclusive deep inelastic scattering (SIDIS) of 10.6 GeV longitudinally polarized electrons off the proton has been measured using the CLAS12 detector at Jefferson Lab. Two separate channels, π + π 0 and π - π 0 , were analyzed, requiring the reconstruction of diphoton pairs. Here, in this analysis, we addressed the problem of false neutral particles being reconstructed by CLAS12's event builder, polluting the otherwise physical combinatorial background underneath the π 0 peak. A photon classifier using a Gradient Boosted Trees (GBTs) architecture was trained with Monte Carlo simulations to reduce the amount of background π 0 's. We show that the nearest-neighbor features learned by the model lead to a substantial increase in signal vs. background discrimination compared to previous CLAS12 π^0 analyses. The machine learning approach recovers several times more dihadron statistics for the dataset.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Batch VUV4 characterization for the SBC-LAr10 scintillating bubble chamber

The Scintillating Bubble Chamber (SBC) collaboration purchased 32 Hamamatsu VUV4 silicon photomultipliers (SiPMs) for use in SBC-LAr10, a bubble chamber containing 10 kg of liquid argon. A dark-count characterization technique, which avoids the use of a single-photon source, was used at two temperatures to measure the VUV4 SiPMs breakdown voltage (V BD ), the SiPM gain (g SiPM ), the rate of change of g SiPM with respect to voltage (m), the dark count rate (DCR), and the probability of a correlated avalanche (P CA ) as well as the temperature coefficients of these parameters. A Peltier-based chilled vacuum chamber was developed at Queen's University to cool down the Quads to 233.15 ± 0.2 K and 255.15 ± 0.2 K with average stability of ±20 mK. An analysis framework was developed to estimate V BD to tens of mV precision and DCR close to Poissonian error. The temperature dependence of V BD was found to be 56 ± 2 mV K -1 , and m on average across all Quads was found to be (459 ± 3(stat.)±23(sys.))× 10 3 e- PE -1 V -1 . The average DCR temperature coefficient was estimated to be 0.099 ± 0.008 K -1 corresponding to a reduction factor of 7 for every 20 K drop in temperature. The average temperature dependence of P CA was estimated to be 4000 ± 1000 ppm K -1 . P CA estimated from the average across all SiPMs is a better estimator than the P CA calculated from individual SiPMs, for all of the other parameters, the opposite is true. All the estimated parameters were measured to the precision required for SBC-LAr10, and the Quads will be used in conditions to optimize the signal-to-noise ratio.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗