Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “material point method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

Evaluation of Liver Function After Proton Beam Therapy for Hepatocellular Carcinoma

Purpose: Our previous results for treatment of hepatocellular carcinoma with proton beam therapy (PBT) revealed excellent local control. In this study, we focused on the impact of PBT on normal liver function. Methods and Materials: The subjects were 259 patients treated with PBT at University of Tsukuba between January 2001 and December 2007. We evaluated the Child-Pugh score pretreatment, on the final day of PBT, and 6, 12, and 24 months after treatment with PBT. Patients who had disease progression or who died with tumor progression at each evaluation point were excluded from the analysis to rule out an effect of tumor progression. An increase in the Child-Pugh score of 1 or more was defined as an adverse event. Results: Of the 259 patients, 241 had no disease progression on the final day of PBT, and 91 had no progression within 12 months after PBT. In univariate analysis, the percentage volumes of normal liver receiving at least 0, 10, 20, and 30 GyE in PBT (V0, 10, 20, and 30) were significantly associated with an increase of Child-Pugh score at 12 months after PBT. Of the 91 patients evaluated at 12 months, 66 had no increase of Child-Pugh score, 15 had a 1-point increase, and 10 had an increase of {>=}2 points. For the Youden index, the optimal cut-offs for V0, V10, V20, and V30 were 30%, 20%, 26%, and 18%, respectively. Conclusion: Our findings indicate that liver function after PBT is significantly related to the percentage volume of normal liver that is not irradiated. This suggests that further study of the relationship between liver function and PBT is required.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantification of Esophageal Tumor Motion on Cine-Magnetic Resonance Imaging

Purpose: To quantify the movement of esophageal tumors noninvasively on cine-magnetic resonance imaging (MRI) by use of a semiautomatic method to visualize tumor movement directly throughout multiple breathing cycles. Methods and Materials: Thirty-six patients with esophageal tumors underwent MRI. Tumors were located in the upper (8), middle (7), and lower (21) esophagus. Cine-MR images were collected in the coronal and sagittal plane during 60 seconds at a rate of 2 Hz. An adaptive correlation filter was used to automatically track a previously marked reference point. Tumor movement was measured in the craniocaudal (CC), left–right (LR), and anteroposterior (AP) directions and its relationship along the longitudinal axis of the esophagus was investigated. Results: Tumor registration within the individual images was typically done at a millisecond time scale. The mean (SD) peak-to-peak displacements in the CC, AP, and LR directions were 13.3 (5.2) mm, 4.9 (2.5) mm, and 2.7 (1.2) mm, respectively. The bandwidth to cover 95% of excursions from the mean position (c95) was also calculated to exclude outliers caused by sporadic movements. The mean (SD) c95 values were 10.1 (3.8) mm, 3.7 (1.9) mm, and 2.0 (0.9) mm in the CC, AP, and LR dimensions. The end-exhale phase provided a stable position in the respiratory cycle, compared with more variety in the end-inhale phase. Furthermore, lower tumors showed more movement than did higher tumors in the CC and AP directions. Conclusions: Intrafraction tumor movement was highly variable between patients. Tumor position proved the most stable during the respiratory cycle in the end-exhale phase. A better understanding of tumor motion makes it possible to individualize radiation delivery strategies accordingly. Cine-MRI is a successful noninvasive modality to analyze motion for this purpose in the future.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose-Dependent Cortical Thinning After Partial Brain Irradiation in High-Grade Glioma

Purpose: Radiation-induced cognitive deficits may be mediated by tissue damage to cortical regions. Volumetric changes in cortex can be reliably measured using high-resolution magnetic resonance imaging (MRI). We used these methods to study the association between radiation therapy (RT) dose and change in cortical thickness in high-grade glioma (HGG) patients. Methods and Materials: We performed a voxel-wise analysis of MRI from 15 HGG patients who underwent fractionated partial brain RT. Three-dimensional MRI was acquired pre- and 1 year post RT. Cortex was parceled with well-validated segmentation software. Surgical cavities were censored. Each cortical voxel was assigned a change in cortical thickness between time points, RT dose value, and neuroanatomic label by lobe. Effects of dose, neuroanatomic location, age, and chemotherapy on cortical thickness were tested using linear mixed effects (LME) modeling. Results: Cortical atrophy was seen after 1 year post RT with greater effects at higher doses. Estimates from LME modeling showed that cortical thickness decreased by −0.0033 mm (P<.001) for every 1-Gy increase in RT dose. Temporal and limbic cortex exhibited the largest changes in cortical thickness per Gy compared to that in other regions (P<.001). Age and chemotherapy were not significantly associated with change in cortical thickness. Conclusions: We found dose-dependent thinning of the cerebral cortex, with varying neuroanatomical regional sensitivity, 1 year after fractionated partial brain RT. The magnitude of thinning parallels 1-year atrophy rates seen in neurodegenerative diseases and may contribute to cognitive decline following high-dose RT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Microwave-assisted hydrothermal synthesis of porous SnO{sub 2} nanotubes and their lithium ion storage properties

Porous SnO{sub 2} nanotubes have been synthesized by a rapid microwave-assisted hydrothermal process followed by annealing in air. The detailed morphological and structural studies indicate that the SnO{sub 2} tubes typically have diameters from 200 to 400 nm, lengths from 0.5 to 1.5 {mu}m and wall thicknesses from 50 to 100 nm. The SnO{sub 2} nanotubes are self-assembled by interconnected nanocrystals with sizes {approx}8 nm resulting in a specific surface area of {approx}54 m{sup 2} g{sup -1}. The pristine SnO{sub 2} nanotubes are used to fabricate lithium half cells to evaluate their lithium ion storage properties. The porous SnO{sub 2} nanotubes are characteristic with high lithium ion storage capacity, that is found to be 1258, 951, 757, 603, 458, and 288 mAh g{sup -1}, at 0.1, 0.2, 0.5, 1, 2, and 4C, respectively. The enhanced electrochemical properties of the SnO{sub 2} nanotubes can be ascribed to their unique geometry and porous structures. - Graphical abstract: Porous SnO{sub 2} nanotubes are synthesized by a fast microwave-assisted hydrothermal process and exhibit high lithium ion storage properties due to their unique geometry and porous characteristics. Highlights: Black-Right-Pointing-Pointer A microwave-assisted hydrothermal method was used to prepare porous SnO{sub 2} nanotubes. Black-Right-Pointing-Pointer The porous SnO{sub 2} nanotubes have abundant mesopores on their tube walls. Black-Right-Pointing-Pointer The porous SnO{sub 2} nanotubes possess high lithium ion storage properties. Black-Right-Pointing-Pointer Our results may promote the development of high-performance anode materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Design, manufacture, and evaluation of an anthropomorphic pelvic phantom purpose-built for radiotherapy dosimetric intercomparison

Purpose: An anthropomorphic pelvic phantom was designed and constructed to meet specific criteria for multicenter radiotherapy dosimetric intercomparison. Methods: Three dimensional external and organ outlines were generated from a computed tomography image set of a male pelvis, forming the basis of design for an anatomically realistic phantom. Clinically relevant points of interest were selected throughout the dataset where point-dose values could be measured with thermoluminescence dosimeters and a small-volume ionization chamber. Following testing, three materials were selected and the phantom was manufactured using modern prototyping techniques into five separate coronal slices. Time lines and resource requirements for the phantom design and manufacture were recorded. The ability of the phantom to mimic the entire treatment chain was tested. Results: The phantom CT images indicated that organ densities and geometries were comparable to those of the original patient. The phantom proved simple to load for dosimetry and rapid to assemble. Due to heat release during manufacture, small air gaps and density heterogeneities were present throughout the phantom. The overall cost for production of the prototype phantom was comparable to other commercial anthropomorphic phantoms. The phantom was shown to be suitable for use as a ''patient'' to mimic the entire treatment chain for typical external beam radiotherapy for prostate and rectal cancer. Conclusions: The phantom constructed for the present study incorporates all characteristics necessary for accurate Level III intercomparison studies. Following use in an extensive Level III dosimetric comparison over a large time scale and geographic area, the phantom retained mechanical stability and did not show signs of radiation-induced degradation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mixed-Mode-Bending Delamination Apparatus

Mixed-mode-bending delamination apparatus generates two types of delamination stress simultaneously in specimen from single externally applied point load. In technique, indivial mode I and mode II contributions to delamination in specimen analyzed by use of simple beam-theory equations, eliminating need for time-consuming, difficult numerical analysis. Allows wider range of mode I/mode II ratios than possible with many other methods. Mixed-mode delamination testing of interest in all fields utilizing composite materials, used mostly in aerospace field, but also used in automobiles, lightweight armored military vehicles, boats, and sporting equipment. Useful in general lumber, plywood, and adhesive industries, as well.

Crews, John H., Jr.↗

Phased Array Beamforming and Imaging in Composite Laminates Using Guided Waves

This paper presents the phased array beamforming and imaging using guided waves in anisotropic composite laminates. A generic phased array beamforming formula is presented, based on the classic delay-and-sum principle. The generic formula considers direction-dependent guided wave properties induced by the anisotropic material properties of composites. Moreover, the array beamforming and imaging are performed in frequency domain where the guided wave dispersion effect has been considered. The presented phased array method is implemented with a non-contact scanning laser Doppler vibrometer (SLDV) to detect multiple defects at different locations in an anisotropic composite plate. The array is constructed of scan points in a small area rapidly scanned by the SLDV. Using the phased array method, multiple defects at different locations are successfully detected. Our study shows that the guided wave phased array method is a potential effective method for rapid inspection of large composite structures.

Tian, Zhenhua↗

Methods and systems for 3D printing with powders

A method of printing a three dimensional article (201) can include forming a bottom layer of the three dimensional article (201) by spraying a dry build material powder (210) onto a build platform (230) while heating the dry build material powder (210). The dry build material powder (210) can include metal or ceramic particles mixed with a polymeric binder having a softening point temperature. The dry build material powder (210) can be heated to a temperature above the softening point temperature such that the dry build material powder (210) adheres to the build platform (230). Subsequent layers can be formed by spraying dry build material powder (210) onto a lower layer while heating the dry build material powder (210) such that the dry build material powder (210) adheres to the lower layer.

Fang, Zhigang Zak↗

Influence of Ga/N ratio on morphology, vacancies, and electrical transport in GaN grown by molecular beam epitaxy at high temperature

The effect of Ga/N flux ratio on surface morphology, incorporation of point defects and electrical transport properties of GaN films grown by plasma-assisted molecular beam epitaxy in a recently developed high-temperature growth regime was investigated. The homoepitaxial (0001) GaN films grown at {approx}780-790 deg. C showed smoothest morphologies near the cross-over between N-rich and Ga-rich growth (0.75<Ga/N<1.1) contrasting previous observations for low-temperature growth. The higher-quality growth near Ga/N{approx}1 resulted from lower thermal decomposition rates and was corroborated by slightly lower Ga vacancy concentrations [V{sub Ga}], lower unintentional oxygen incorporation, and improved electron mobilities. The consistently low [V{sub Ga}], i.e., {approx}10{sup 16} cm{sup -3} for all films attribute further to the significant benefits of the high-temperature growth regime.

36 MATERIALS SCIENCE↗

Fire safety experiments on MIR Orbital Station

The process of heterogeneous combustion of most materials under zero-g without forced motion of air is practically impossible. However, ventilation is required to support astronauts' life and cool equipment. The presence of ventilation flows in station compartments at accidental ignition can cause a fire. An additional, but exceedingly important parameter of the fire risk of solid materials under zero-g is the minimum air gas velocity at which the extinction of materials occurs. Therefore, the conception of fire safety can be based on temporarily lowering the intensity of ventilation and even turning it off. The information on the limiting conditions of combustion under natural conditions is needed from both scientific and practical points of view. It will enable us to judge the reliability of results of ground-based investigations and develop a conception of fire safety of inhabited sealed compartments of space stations to by provided be means of nontraditional and highly-effective methods without both employing large quantities of fire-extinguishing compounds and hard restrictions on use of polymers. In this connection, an experimental installation was created to study the process of heterogeneous combustion of solid non-metals and to determine the conditions of its extinction under microgravity. This installation was delivered to the orbital station 'Mir' and the cosmonauts Viktorenko and Kondakova performed initial experiments on it in late 1994. The experimental installation consists of a combustion chamber with an electrical systems for ignition of samples, a device for cleaning air from combustion products, an air suction unit, air pipes and a control panel. The whole experiment is controlled by telemetry and recorded with two video cameras located at two different places. Besides the picture, parameters are recorded to determine the velocity of the air flow incoming to the samples, the time points of switching on/off the devices, etc. The combustion chamber temperature is also controlled. The main objectives of experiments of this series were as follows: (1) verification of the reliability of the installation in orbital flight; (2) verification of the experimental procedure; and (3) investigation of combustion of two types of materials under microgravity at various velocities of the incoming air flow.

Egorov, S. D.↗

Enhancing Cluster Identification in Atom Probe Tomography Data Using Transfer Learning

Atom Probe Tomography (APT) is a powerful technique for visualizing the atomic-scale distribution of solutes in materials, but quantitative cluster analysis of APT datasets remains a challenge due to the need for subjective parameter selection in clustering algorithms. While distance-based and density-based methods such as HDBSCAN are widely used, their performance is highly sensitive to user-defined parameters, which undermines reproducibility and accuracy. This study proposes an image-based, deep learning-aided workflow for automating parameter selection and cluster detection in APT data analysis. By projecting 3D APT point clouds onto 2D planes, we leverage pretrained convolutional neural networks (ConvNeXt-Tiny and ResNet-50) through transfer learning to predict the number of clusters present in synthetic datasets. The output is used to guide K-means clustering and estimate HDBSCAN parameters, specifically minimum cluster size and minimum sample points. This approach reduces reliance on manual parameter tuning, improving consistency and scalability. The methodology demonstrates the feasibility of using image-based deep learning for interpreting complex spatial patterns in APT data, enabling faster and more objective analysis. The complete workflow and code are made publicly available to support reproducibility and future research.

Density-based clustering↗

Apportionment of ambient primary and secondary fine particulate matter at the Pittsburgh National Energy Laboratory particulate matter characterization site using positive matrix factorization and a potential source contributions function analysis

Fine particulate matter (PM2.5) concentrations associated with 202 24-hr samples collected at the National Energy Technology Laboratory (NETL) particulate matter (PM) characterization site in south Pittsburgh from October 1999 through September 2001 were used to apportion PM2.5 into primary and secondary contributions using Positive Matrix Factorization (PMF2). Input included the concentrations of PM2.5 mass determined with a Federal Reference Method (FRM) sampler, semi-volatile PM2.5 organic material, elemental carbon (EC), and trace element components of PM2.5. A total of 11 factors were identified. The results of potential source contributions function (PSCF) analysis using PMF2 factors and HYSPLIT-calculated back-trajectories were used to identify those factors associated with specific meteorological transport conditions. The 11 factors were identified as being associated with emissions from various specific regions and facilities including crustal material, gasoline combustion, diesel combustion, and three nearby sources high in trace metals. Three sources associated with transport from coal-fired power plants to the southeast, a combination of point sources to the northwest, and a steel mill and associated sources to the west were identified. In addition, two secondary-material-dominated sources were identified, one was associated with secondary products of local emissions and one was dominated by secondary ammonium sulfate transported to the NETL site from the west and southwest. Of these 11 factors, the four largest contributors to PM2.5 were the secondary transported material (dominated by ammonium sulfate) (47%), local secondary material (19%), diesel combustion emissions (10%), and gasoline combustion emissions (8%). The other seven factors accounted for the remaining 16% of the PM2.5 mass. The findings are consistent with the major source of PM2.5 in the Pittsburgh area being dominated by ammonium sulfate from distant transport and so decoupled from local activity emitting organic pollutants in the metropolitan area. In contrast, the major local secondary sources are dominated by organic material.

02 PETROLEUM↗

Investigating Core Gaps and the Development of Subcomponent Validation Methods for Wind Turbine Blades: Preprint

Core gaps are a common manufacturing defect observed in wind blade composite sandwich constructions, which occur when sheets of core material are not properly butted up against each other in the mold. The aim of this study was to characterize core gaps in composite sandwich constructions at the coupon scale. This was to gain an initial understanding of the defect before developing appropriate methodologies for more complex subcomponents as part of a much broader wind blade structural validation and damage tolerance program. Long beam flexure in 4-point-bending was chosen as the most appropriate loading scenario. Beam specimens were characterized with and without 10 mm core gaps in fiberglass/balsa sandwich beams. The core gaps were characterized with two separate resin systems; a Hexion epoxy and Arkema's Elium resins system (a novel, infusible thermoplastic). Results showed that the Elium beams without the core gaps were had a 15% lower static strength than their epoxy counterparts. The introduction of the core gap to the epoxy beams reduced their static strength by 35%. The Elium beams, however, exhibited negligible strength reductions with the inclusion of the core gap. Overall, this characterization study provided pertinent information with regards to core gaps as a manufacturing defect to allow for continued development of damage tolerance and subcomponent validation methodologies with the inclusion of manufacturing defects.

17 WIND ENERGY↗

Investigation of New d{sup 0} Half-metallic Heusler Alloy LiCsN{sub 2} Using First-Principle Calculations

Using the self-consistent full-potential linearized augmented plane wave (FPLAPW) method, we predicated a new d{sup 0} half-metallic Heusler compound LiCsN{sub 2} with integer total magnetic moment 4.00 μ B per formula unit based on density functional theory (DFT). Our calculation shows that this alloy has a huge half-metallic gap (1.06 eV) and a wide band gap (4.52 eV). We found the LiCsN{sub 2} alloy is a robust half-metallic material with respect to the lattice compression. It maintains the half-metallic character until the lattice constant is contracted to 6.10 Å. The Curie temperature of LiCsN{sub 2} was estimated to be 6145.4 K within the mean field approximations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Towards predictive band gaps for halide perovskites: Lessons from one-shot and eigenvalue self-consistent GW

Halide perovskites constitute a chemically diverse class of crystals with great promise as photovoltaic absorber materials, featuring band gaps between about 1 and 3.5 eV depending on composition. Their diversity calls for a general computational approach to predicting their band gaps. However, such an approach is still lacking. Here, we use density functional theory (DFT) and ab initio many-body perturbation theory within the GW approximation to compute the quasiparticle or fundamental band gap of a set of ten representative halide perovskites: CH 3 NH 3 PbI 3 ( MAPbI 3 ), MAPbBr 3 , CsSnBr 3 , ( MA ) 2 BiTlBr 6 , Cs 2 TlAgBr 6 , Cs 2 TlAgCl 6 , Cs 2 BiAgBr 6 , Cs 2 InAgCl 6 , Cs 2 SnBr 6 , and Cs 2 Au 2 I 6 . Comparing with recent measurements, we find that a standard generalized gradient exchange-correlation functional can significantly underestimate the experimental band gaps of these perovskites, particularly in cases with strong spin-orbit coupling (SOC) and highly dispersive band edges, to a degree that varies with composition. We show that these nonsystematic errors are inherited by one-shot G 0 W 0 and eigenvalue self-consistent GW 0 calculations, demonstrating that semilocal DFT starting points are insufficient for MAPbI 3 , MAPbBr 3 , CsSnBr 3 , ( MA ) 2 BiTlBr 6 , Cs 2 TlAgBr 6 , and Cs 2 TlAgCl 6 . On the other hand, we find that DFT with hybrid functionals leads to an improved starting point and G W 0 results in better agreement with experiment for these perovskites. Our results suggest that G W 0 with hybrid functional-based starting points are promising for predicting band gaps of systems with large SOC and dispersive bands in this technologically important class of semiconducting crystals.</

36 MATERIALS SCIENCE↗

Three-dimensional reconstruction and morphologic characteristics of porous metal fiber sintered sheet

This paper presents an approach to achieve morphological characterizing for complex porous materials based on micro X-ray tomography images, with an example of a novel porous metal fiber sheet produced through solid-state sintering method. The geometrical reconstruction was performed after selection of volume of interest and image processing of anisotropic diffusion smooth. The reconstructed gray level images were then transferred into binary images by adjusting binarization threshold according to the actual porosity. Taking into account the tubular structural feature of the fibers, skeleton extraction algorithm based on the distance transform function was applied and further improved by the scale axis transform method. The skeleton was later pruned and segmented according to the contact points to perform morphological characterizing. Compared with actual manufacturing parameters, the style, length, radius, orientation and tortuosity of fiber segments were discussed. The results show that our proposed method can well describe the actual geometrical and morphological characteristics, which will provide a promising method for the structural description of fibrous networks. - Highlights: • Micro-CT technology was used to achieve the 3D geometrical reconstruction. • Skeleton extraction algorithm was modified to get the medial skeleton. • Skeleton filter operation was adopted to deal with the segmented skeleton. • Useful morphological statistics was obtained through skeleton segments. • Relationship between structure and manufacturing processes was discussed.

36 MATERIALS SCIENCE↗

Frameless Angiogram-Based Stereotactic Radiosurgery for Treatment of Arteriovenous Malformations

Purpose: Stereotactic radiosurgery (SRS) is an effective alternative to microsurgical resection or embolization for definitive treatment of arteriovenous malformations (AVMs). Digital subtraction angiography (DSA) is the gold standard for pretreatment diagnosis and characterization of vascular anatomy, but requires rigid frame (skull) immobilization when used in combination with SRS. With the advent of advanced proton and image-guided photon delivery systems, SRS treatment is increasingly migrating to frameless platforms, which are incompatible with frame-based DSA. Without DSA as the primary image, target definition may be less than optimal, in some cases precluding the ability to treat with a frameless system. This article reports a novel solution. Methods and Materials: Fiducial markers are implanted into the patient's skull before angiography. Angiography is performed according to the standard clinical protocol, but, in contrast to the previous practice, without the rigid frame. Separate images of a specially designed localizer box are subsequently obtained. A target volume projected on DSA can be transferred to the localizer system in three dimensions, and in turn be transferred to multiple CT slices using the implanted fiducials. Combined with other imaging modalities, this 'virtual frame' approach yields a highly precise treatment plan that can be delivered by frameless SRS technologies. Results: Phantom measurements for point and volume targets have been performed. The overall uncertainty of placing a point target to CT is 0.4 mm. For volume targets, deviation of the transformed contour from the target CT image is within 0.6 mm. The algorithm and software are robust. The method has been applied clinically, with reliable results. Conclusions: A novel and reproducible method for frameless SRS of AVMs has been developed that enables the use of DSA without the requirement for rigid immobilization. Multiple pairs of DSA can be used for better conformality. Further improvement, including using nonimplanted fiducials, is potentially feasible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fabrication of High Surface Area Microporous ZnO from ZnO/Carbon Sacrificial Composite Monolith Template

Fabrication of porous materials from the standard sacrificial template method allows metal oxide nanostructures to be produced and have several applications in energy, filtration and constructing sensing devices. However, the low surface area of these nanostructures is a significant drawback for most applications. Here, we report the synthesis of ZnO/carbon composite monoliths in which carbon is used as a sacrificial template to produce zinc oxide (ZnO) porous nanostructures with a high specific surface area. The synthesized porous oxides of ZnO with a specific surface area of 78 m2/g are at least one order of magnitude higher than that of the ZnO nanotubes reported in the literature. The crucial point to achieving this remarkable result was the usage of a novel ZnO/carbon template where the carbon template was removed by simple heating in the air. As a high surface area porous nanostructured ZnO, these synthesized materials can be useful in various applications including catalysis, photocatalysis, separation, sensing, solar energy harvest and Zn-ion battery and as supercapacitors for energy storage.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗