Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “low dose”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

Applicability of the Nasa Galactic Cosmic Ray Simulator for Mice, Rats, and Minipigs

Space radiation poses multiple health risks to astronauts including cancer, cardiovascular disease, and damage to the central nervous system. Radiation from galactic cosmic rays (GCR) is the main source of these risks for missions beyond low Earth orbit to the moon and beyond. A galactic cosmic ray simulator (GCRsim) was developed at the NASA Space Radiation Laboratory to better understand and mitigate these risks by simulating the complex mixed field of the GCR environment at a ground-based facility. The GCRsim delivers a radiation field to cell and animal models in a laboratory setting that is comparable to the shielded radiation environment within internal organs of astronauts in deep space missions. Previous verification studies using Monte Carlo simulations with mouse (Digimouse) and rat (Digirat) digital phantoms showed that the GCRsim yields acceptable dose homogeneity within the internal organs of these animals. Spectral characteristics of the intended space radiation environment are also accurately reproduced at radiosensitive sites in both phantoms. In this work, similar Monte Carlo simulations were performed in a minipig model (Digipig) to show the applicability and limitations of the current GCRsim for larger animal model systems. The results showed dose homogeneity in internal organs of the three animal models with GCRsim irradiation. While slightly lower average doses were seen in the minipig compared to the external beam dose, the individual voxel doses in slices of the phantoms were found to be within 6%–8% of the average voxel dose, establishing that the GCRsim can still provide a relatively homogeneous irradiation within larger animals. Furthermore, simulated dose and fluence spectral results across the relevant linear energy transfer (LET) range agreed well with the reference field in the most relevant regions of the spectra, further verifying that the GCRsim beam represents the reference field in larger animals.

Galactic cosmic rays↗

Simultaneous observation of the radiation environment inside and outside the ISS

The low-Earth orbit (LEO) radiation environment has been directly observed by the IV and EV charged particle directional spectrometers (CPDS) aboard the International Space Station (ISS). The EV instrument is mounted on the S0 truss of the ISS and consists of three separate silicon detector telescopes which are oriented in different directions. The IV instrument is a single silicon detector telescope located inside the US Laboratory module of the ISS. We report on the current state of the data analysis for these instruments, which includes the proton and He stopping particle spectra, relative CNO abundances, LET spectra, and measured dose rate as a function of time.

Lee, K. T.↗

High-resolution planar electron beam induced current in bulk diodes using high-energy electrons

Understanding the impact of high-energy electron radiation on device characteristics remains critical for the expanding use of semiconductor electronics in space-borne applications and other radiation harsh environments. Here in this paper, we report on in situ measurements of high-energy electron radiation effects on the hole diffusion length in low threading dislocation density homoepitaxial bulk n-GaN Schottky diodes using electron beam induced current (EBIC) in high-voltage scanning electron microscopy mode. Despite the large interaction volume in this system, quantitative EBIC imaging is possible due to the sustained collimation of the incident electron beam. This approach enables direct measurement of electron radiation effects without having to thin the specimen. Using a combination of experimental EBIC measurements and Monte Carlo simulations of electron trajectories, we determine a hole diffusion length of 264 ± 11 nm for n-GaN. Irradiation with 200 kV electron beam with an accumulated dose of 24 × 10 16 electrons cm -2 led to an approximate 35% decrease in the minority carrier diffusion length.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Single-Dose Vaccination with a Hepatotropic Adeno-associated Virus Efficiently Localizes T Cell Immunity in the Liver with the Potential To Confer Rapid Protection against Hepatitis C Virus

Hepatitis C virus (HCV) is a significant contributor to the global disease burden, and development of an effective vaccine is required to eliminate HCV infections worldwide. CD4 + and CD8 + T cell immunity correlates with viral clearance in primary HCV infection, and intrahepatic CD8 + tissue-resident memory T (T RM ) cells provide lifelong and rapid protection against hepatotropic pathogens. Consequently, we aimed to develop a vaccine to elicit HCV-specific CD4 + and CD8 + T cells, including CD8 + T RM cells, in the liver, given that HCV primarily infects hepatocytes. To achieve this, we vaccinated wild-type BALB/c mice with a highly immunogenic cytolytic DNA vaccine encoding a model HCV (genotype 3a) nonstructural protein (NS5B) and a mutant perforin (pVAX-NS5B-PRF), as well as a recombinant adeno-associated virus (AAV) encoding NS5B (rAAV-NS5B). A novel fluorescent target array (FTA) was used to map immunodominant CD4 + T helper (T H ) cell and cytotoxic CD8 + T cell epitopes of NS5B in vivo , which were subsequently used to design a K d NS5B 451-459 tetramer and analyze NS5B-specific T cell responses in vaccinated mice in vivo . The data showed that intradermal prime/boost vaccination with pVAX-NS5B-PRF was effective in eliciting T H and cytotoxic CD8 + T cell responses and intrahepatic CD8 + T RM cells, but a single intravenous dose of hepatotropic rAAV-NS5B was significantly more effective. As a T-cell-based vaccine against HCV should ideally result in localized T cell responses in the liver, this study describes primary observations in the context of HCV vaccination that can be used to achieve this goal. There are currently at least 71 million individuals with chronic HCV worldwide and almost two million new infections annually. Although the advent of direct-acting antivirals (DAAs) offers highly effective therapy, considerable remaining challenges argue against reliance on DAAs for HCV elimination, including high drug cost, poorly developed health infrastructure, low screening rates, and significant reinfection rates. Accordingly, development of an effective vaccine is crucial to HCV elimination. An HCV vaccine that elicits T cell immunity in the liver will be highly protective for the following reasons: (i) T cell responses against nonstructural proteins of the virus are associated with clearance of primary infection, and (ii) long-lived liver-resident T cells alone can protect against malaria infection of hepatocytes. Thus, in this study we exploit promising vaccination platforms to highlight strategies that can be used to evoke highly functional and long-lived T cell responses in the liver for protection against HCV.

59 BASIC BIOLOGICAL SCIENCES↗

The development of Nanosota-1 as anti-SARS-CoV-2 nanobody drug candidates

Combating the COVID-19 pandemic requires potent and low-cost therapeutics. We identified a series of single-domain antibodies (i.e., nanobody), Nanosota-1, from a camelid nanobody phage display library. Structural data showed that Nanosota-1 bound to the oft-hidden receptor-binding domain (RBD) of SARS-CoV-2 spike protein, blocking viral receptor angiotensin-converting enzyme 2 (ACE2). The lead drug candidate possessing an Fc tag (Nanosota-1C-Fc) bound to SARS-CoV-2 RBD ~3000 times more tightly than ACE2 did and inhibited SARS-CoV-2 pseudovirus ~160 times more efficiently than ACE2 did. Administered at a single dose, Nanosota-1C-Fc demonstrated preventive and therapeutic efficacy against live SARS-CoV-2 infection in both hamster and mouse models. Unlike conventional antibodies, Nanosota-1C-Fc was produced at high yields in bacteria and had exceptional thermostability. Pharmacokinetic analysis of Nanosota-1C-Fc documented an excellent in vivo stability and a high tissue bioavailability. As effective and inexpensive drug candidates, Nanosota-1 may contribute to the battle against COVID-19.

60 APPLIED LIFE SCIENCES↗

Neutron measurements onboard the space shuttle

The radiation environment inside a shielded volume is highly complex, consisting of both charged and neutral particles. Since the inception of human space flights, the charged particle component has received virtually all of the attention. There is however, a significant production of secondary neutrons, particularly from the aluminum structure in low earth orbiting spacecrafts. The interactions of galactic cosmic rays (GCR), and solar energetic particles with the earth's atmosphere produce a non-isotropic distribution of albedo neutrons. Inside any reasonable habitable module, the average radiation quality factor of neutrons is about 4-5 times larger than the corresponding average quality factor of charged particles. The measurement of neutrons and their energy spectra is a difficult problem due the intense sources of charged particles. This paper reviews the results of Shuttle flight experiments (made during both solar maximum and solar minimum) to measure the contribution of neutrons to the dose equivalent, as well as theoretical calculations to estimate the appropriate range of neutron energies that contribute most to the dose equivalent. Published by Elsevier Science Ltd.

short duration↗

Space radiation effects on the thermo-mechanical behavior of graphite-epoxy composites

This investigation of composite material properties utilized T300/934 graphite-epoxy that was subjected to 1.0 MeV electron radiation for a total dose of 1.0 x 10 to the 10th rads at a rate of 5.0 x 10 to the 7th rads/hour, simulating a worst-case exposure equivalent to 30 years in space. Mechanical testing was performed on 4-ply unidirectional laminates over the temperature range of -250 F (116 K) to +250 F (394 K). In-plane elastic tensile and shear properties as well as strength were obtained. The results show that electron radiation degrades the epoxy matrix and produces products that volatilize at the temperatures considered. These degradation products plasticize the epoxy at elevated temperatures and embrittle it at low temperatures, thereby altering the mechanical properties of the composite.

Milkovich, Scott M.↗

Low-resistance noble metal contacts to high-temperature superconductors

Low-resistance contacts were made to both YBa2Cu3O(7-x) and Bi2BaSr2Cu2O8, and to related superconducting compounds by melting gold or silver pads onto the samples before the final oxygen treatment. Scanning electron microscope studies show that both gold and silver do not diffuse far from the contact area. The surface contact resistivity of the best contacts made by the melting technique has an upper limit value in the 10 to the -8th ohm sq cm range at 77 K. This contact resistivity shows no significant change in its value over a period of 17 months. Furthermore, an electron radiation dose of 5.7 x 10 to the 17th electron/sq cm only doubled the contact resistivity.

Selim, R.↗

Initial Developments in Modeling Graphite Behavior

Graphite is used in High Temperature Reactor designs as a moderator, reflector and core material responsible for protecting the fuel and maintaining structural stability. From a safety perspective, it is imperative to be able to predict how graphite will behave under reactor operating conditions which may compromise the core’s structural integrity or fuel’s safety performance. The following report summarizes recent modeling work undertaken at Idaho National Laboratory which focuses on graphite degradation behavior. One phenomenon which is explored in this report and can cause significant degradation to graphite properties is oxidation. Oxidation behavior in graphite is highly temperature dependent. At low temperatures, oxygen can fully penetrate a component and cause a homogeneous damage profile. At high temperatures, only the graphite near the surface of a component is affected. Understanding and modeling this temperature dependence is essential to predicting graphite behavior. In this report, three graphite models are discussed. The first model is used to investigate strength loss after low temperature oxidation. It does this by generating an approximate graphite microstructure then determining the required load to cause crack propagation. It has been shown that the model reproduces the quasi brittle stress versus strain relationship observed in graphite. Strength loss results from the model are shown to match experimental values. The second model investigates strength loss under high temperature oxidation conditions. This model is more applicable to full scale graphite components where the oxidation damage is often inhomogeneous throughout a component. The third model computes stresses in graphite under reactor conditions. Specifically, the model incorporates the effect of creep, irradiation dose, thermal strains, and oxidation in order to predict internal stresses in a component. All of these models are implemented in the Multiphysics Object-Oriented Simulation Environment (MOOSE), an open source, parallel finite element framework.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Ion-kill dosimetry

Unanticipated late effects in neutron and heavy ion therapy, not attributable to overdose, imply a qualitative difference between low and high LET therapy. We identify that difference as 'ion kill', associated with the spectrum of z/beta in the radiation field, whose measurement we label 'ion-kill dosimetry'.

NASA Center JSC↗

Polymeric Materials With Additives for Durability and Radiation Shielding in Space

Polymeric materials are attractive for use in space structures because of their light weight and high strength In addition, polymers are made of elements with low atomic numbers (Z), primarily carbon (C), hydrogen (H), oxygen (0), and nitrogen (N) which provide the best shielding from galactic cosmic rays (GCR) (ref. 1). Galactic cosmic rays are composed primarily of nuclei (i.e., fully ionized atoms) plus a contribution of about 2% from electrons and positrons. There is a small but significant component of GCR particles with high charge (Z > 10) and high energy (E >100 GeV) (ref. 2). These so-called HZE particles comprise only 1 to 2% of the cosmic ray fluence but they interact with very high specific ionization and contribute 50% of the long- term dose to humans. The best shield for this radiation would be liquid hydrogen, which is not feasible. For this reason, hydrogen-containing polymers make the most effective practical shields. Moreover, neutrons are formed in the interactions of GCR particles with materials. Neutrons can only lose energy by collisions or reactions with a nucleus since they are uncharged. This is a process that is much less probable than the Coulombic interactions of charged particles. Thus, neutrons migrate far from the site of the reaction in which they were formed. This increases the probability of neutrons reaching humans or electronic equipment. Fast neutrons (> 1 MeV) can interact with silicon chips in electronic equipment resulting in the production of recoil ions which can cause single event upsets (SEU) in sensitive components (ref. 3). Neutrons lose energy most effectively by elastic collisions with light atoms, particularly hydrogen atoms. Therefore, hydrogen-containing polymers are not only effective in interacting with GCR particles; they are also effective in reducing the energy of the neutrons formed in the interactions.

Kiefer, Richard↗

Recommendations for Using Noise Monitors to Estimate Noise Exposure During X-59 Community Tests

A low fidelity simulation approach is used to explore how to place and use noise monitors during X-59 QueSST community tests, where people’s annoyance to the noise produced by the X-59 aircraft will be gathered. Several recommendations are provided including: 1) the desired number of sparsely spaced noise monitor sites within the survey area, 2) whether to group and average measurements across multiple noise monitors located at a site, 3) what spacing should be used if grouped noise monitors are used, 4) an approach to mitigate ambient noise contamination at the measurement sites, 5) a method to combine empirical and predicted dose estimates to provide a single dose estimate for respondents, and 6) assessing how changes in turbulence intensity and array configuration affect dose uncertainty. To make these recommendations, the error that is expected when fitting contrived, smoothly varying sonic boom “reference exposure surfaces” is studied when a spatially sparse and scattered set of samples is used as responses for the fit. The reference exposure surfaces mimic the sonic boom exposure at ground level that might be expected in the X-59 survey area in the absence of atmospheric turbulence, ambient noise, and other localized effects. The spatial extent of these surfaces varies and is representative of the different survey area sizes that might be expected during future X-59 community overflight tests. These contrived reference surfaces are sampled, and those reference samples are then perturbed to mimic atmospheric turbulence, ambient noise and other localized effects that might affect noise monitor measurements within overflown communities. Two different surface fitting methods are investigated when fitting these perturbed samples to approximate the reference surface. The first method uses interpolation between the perturbed data at the scattered sites to compute the fit. The second method fits a polynomial surface model to the perturbed data using ordinary least squares regression analysis. For both fitting methods, the root mean square fit error is computed from the pointwise difference between the fit surface and the reference surface as the count and configuration of the sites is varied while also averaging the error across many different realizations of both the smooth variation of the reference exposure surface and the random, localized perturbations at the sample sites. Different site configurations are compared using this error statistic to make the recommendations noted above. Additionally, the two fitting approaches (interpolation vs linear regression) are compared based on the fit error observed in these simulations. These analyses, comparisons, and recommendations should inform future decisions on the noise monitor placement and the methods used to analyze the noise monitor data that is collected during X-59 community overflights.

sonic boom↗

Abnormal grain growth driven by high-temperature proton irradiation in nanocrystalline Ni

In this research we examine a nanocrystalline Ni thin film exposed to high-temperature proton irradiation and compare it with as-deposited and annealed-only counterparts. Despite lacking thermal spikes typical of heavy ions, 400 °C proton irradiation drives pronounced grain growth in select grains, whereas annealing alone yields only modest coarsening. Grain-boundary statistics show fewer low-angle boundaries (10–20°) and more high-angle boundaries (55–60°), consistent with irradiation-enhanced mobility of high-misorientation boundaries. The irradiated films retain a random texture, with no evidence of texture development or sharpening. Mechanisms, such as radiation-enhanced grain boundary diffusion, beam-induced heating, and ion channeling-mediated selective grain growth, are unlikely to be the predominant drivers to explain the resultant microstructure. Instead, we suggest irradiation-induced modifications of grain-boundary structure, including possible complexion transitions, as one plausible explanation for this selective grain growth and retention of random texture. However, additional temperature–dose studies are required to confirm the mechanism.

36 MATERIALS SCIENCE↗

Cytoplasmic membrane changes during adaptation of the fresh water cyanobacterium Synechococcus 6311 to salinity

In this investigation, changes were characterized in cell structure and cytoplasmic membrane organization that occur when the freshwater cyanobacterium Synechococcus 6311 is transferred from 'low salt' (0.03 molar NaCl) to 'high salt' (0.5 molar NaCl) media (i.e. sea water concentration). Cells were examined at several time points after the imposition of the salt stress and compared to control cells, in thin sections and freeze fracture electron microscopy, and by flow cytometry. One minute after exposure to high salt, i.e. 'salt shock', virtually all intracellular granules disappeared, the density of the cytoplasm decreased, and the appearance of DNA material was changed. Glycogen and other granules, however, reappeared by 4 hours after salt exposure. The organization of the cytoplasmic membrane undergoes major reorganization following salt shock. Freeze-fracture electron microscopy showed that small intramembrane particles (diameter 7.5 and 8.5 nanometers) are reduced in number by two- to fivefold, whereas large particles, (diameters 14.5 and 17.5 nanometers) increase two- to fourfold in frequency, compared to control cells grown in low salt medium. The changes in particle size distribution suggest synthesis of new membrane proteins, in agreement with the known increases in respiration, cytochrome oxidase, and sodium proton exchange activity of the cytoplasmic membrane.

NASA Discipline Number 61-10↗

High Density Packaging Technologies for RF Electronics in Small Spacecraft

This paper will describe a few high density packaging technologies which we are currently exploring for use in current and future small spacecraft applications. The three categories of technologies include organic multichip modules (MCMs), ceramic leadless surface mount technology (SMT) and 3D printed waveguide structures. There are many other packaging technologies that currently exist but these three were selected in part due to their long heritage in various commercial, military and space applications along with each having a relatively clear path to flight. For each of these technologies, detailed examples will be included in which hardware has been fabricated and tested for use in RF electronics for spacecraft transponders. The organic MCM example will be described in most detail and it utilizes a packaging technology by the name of CoreEZ which is a trademark of i3 Electronics. This MCM has shrunk a portion of our electronics down to 1/8th of its previous area. The CoreEZ technology has been shown to be rad hard beyond a total ionizing dose (TID) of 300kRad and the MCM which was fabricated has gone through thermal cycling and shown to have no degradation in performance. The ceramic leadless package examples include packages from high reliability manufactures by the name of KCB solutions and Barry Industries. In the case of KCB solutions, we have multiple products that will be described including a hermetic ceramic carrier which houses three microwave monolithic integrated circuits (MMICs) along with small discrete components. Finally, we will discuss the results of our search for a 3D printing process that allows us to reduce the cost and volume of our waveguide filters and diplexers for low cost small satellite applications. We have fabricated a few prototypes using direct metal laser sintering (DMLS) and metal coated plastics. Each of these packaging technology discussions will have a brief overview of its current and future use.

Aquirre, Fernando↗

High Density Packaging Technologies for RF Electronics in Small Spacecraft

This paper will describe a few high density packaging technologies which we are currently exploring for use in current and future small spacecraft applications. The three categories of technologies include organic multichip modules (MCMs), ceramic leadless surface mount technology (SMT) and 3D printed waveguide structures. There are many other packaging technologies that currently exist but these three were selected in part due to their long heritage in various commercial, military and space applications along with each having a relatively clear path to flight. For each of these technologies, detailed examples will be included in which hardware has been fabricated and tested for use in RF electronics for spacecraft transponders. The organic MCM example will be described in most detail and it utilizes a packaging technology by the name of CoreEZ which is a trademark of i3 Electronics. This MCM has shrunk a portion of our electronics down to 1/8th of its previous area. The CoreEZ technology has been shown to be rad hard beyond a total ionizing dose (TID) of 300kRad and the MCM which was fabricated has gone through thermal cycling and shown to have no degradation in performance. The ceramic leadless package examples include packages from high reliability manufactures by the name of KCB solutions and Barry Industries. In the case of KCB solutions, we have multiple products that will be described including a hermetic ceramic carrier which houses three microwave monolithic integrated circuits (MMICs) along with small discrete components. Finally, we will discuss the results of our search for a 3D printing process that allows us to reduce the cost and volume of our waveguide filters and diplexers for low cost small satellite applications. We have fabricated a few prototypes using direct metal laser sintering (DMLS) and metal coated plastics. Each of these packaging technology discussions will have a brief overview of its current and future use.

Schatzel, Donald↗

Improving Data Analyses for a Biological Mission to Deep Interplanetary Space

Onboard the Artemis 1 rocket, NASA plans to launch the first deep space bioscience mission past low Earth orbit (LEO) since 1972, BioSentinel, a 6-Unit (6U) biological CubeSat. BioSentinel’s goals are to assess the effect of deep space ionizing radiation (IR) on DNA and cell damage response, using Saccharomyces cerevisiae, or budding yeast, as a model organism. BioSentinel accomplishes this by measuring Optical Density (OD) in addition to metabolic activity using the redox dye alamarBlue, both of which will be read through light emitting diode (LED) lights of differing wavelengths. With the largest and most sophisticated energy-providing solar panels utilized on a biological CubeSat to date, BioSentinel will be equipped with an IR dosimeter to identify what doses of radiation the yeast is exposed to at any point in time, in addition to a transponder to send such data back to NASA Ames’ Multi Mission Operations Center (MMOC). Biology computational programs and data processing scripts are necessary to analyze this complex data once it is received, including automated subroutines to analyze duplication rate, alamarBlue reduction, and time periods when paired against numerous other variables. Overall, we have implemented several VisualBasic biocomputational programs to analyze such data in an organized and efficient manner so that conclusions can be made rapidly. Furthermore, we showcase why efficient analysis of particular parameters is important to better understand the risks that deep space IR poses to astronauts, especially when considering the upcoming Artemis missions.

Bijan Harandi↗

Million Worker Study

Radiation health issues have been an important aspect of DOE's Worker Safety and Health programs. The goal is to ensure that workers are adequately protected from the various radiological hazards associated with DOE sites and operations. Since the early 1940’s DOE has supported the conduct of epidemiologic studies of practically every DOE (AEC) facility and collected these data, now managed by the Oak Ridge Associated Universities (ORAU), in remarkable detail. In the early 2000s, the Office of Health, Safety and Security authorized access to specific DOE worker datasets. Shortly thereafter, the DOE Office of Science provided funds for a pilot study that confirmed the feasibility of the Million Worker Study (MWS), and then additional resources were provided (with other agencies) to extend the follow-up of many populations, not just DOE workers, but also atomic veterans, industrial radiographers, nuclear power plant workers and medical radiation workers (the Million Persons Study (MPS)). This proposal was a continuation of support provided by DOE, specifically to extend the follow-up of the worker populations at the Mallinckrodt Chemical Works (MCW) and Los Alamos National Laboratory (LANL). The work addresses DOE’s interest in clarifying the health risks of their workers as well as contributing knowledge on radiation risks that is relevant today with regard to compensation schemes. The findings are also important for the US public in light of the increased population exposure to medical imaging, environmental circumstances such as hydraulic fracturing, increased exposures during high altitude flights, and with regard to nuclear accidents such as Fukushima and possible terrorist events. Furthermore, it is important to consider reducing the uncertainty in current risk estimates by developing risk coefficients based on healthy American workers who are more representative of U.S. workers and the general public than 1945 Japanese survivors of the atomic bombs living in a war-torn country which experienced deprivation, malnourishment, and increased rates of infections and other diseases. But more importantly, it is important to learn whether radiation exposures received gradually over time (e.g., years) are more or less effective in causing health effects, cancer in particular, than if the radiation dose is received all at once in a fraction of a second as experienced by the Japanese atomic bomb survivors. Finally, the ability to evaluate and combine large populations with intakes of radionuclides such as uranium, radium, plutonium, americium and polonium will provide new quantitative knowledge on human health effects that hitherto has not been possible. This cost-efficient study has built on the investments made and foundations laid by investigators and government agencies, including DOE, over the past 30-40 years, which have established early worker cohorts that can now provide answers to questions on the lifetime human health risks associated with low-level radiation exposures. Collaborating institutions included: International Epidemiology Institute, Oak Ridge Associated Universities, Oak Ridge National Laboratory, Los Alamos National Laboratory, Landauer, Inc., and Vanderbilt University. Follow-up of these two populations and the integration of them with the many other cohorts (now a total of 31) in the MPS continues under a separate DOE grant (DE-AU0000046).

61 RADIATION PROTECTION AND DOSIMETRY↗