At least 1,441 records · Page 80

Controllability of Free-piston Stirling Engine/linear Alternator Driving a Dynamic Load

This paper presents the dynamic behavior of a Free-Piston Stirling Engine/linear alternator (FPSE/LA) driving a single-phase fractional horse-power induction motor. The controllability and dynamic stability of the system are discussed by means of sensitivity effects of variations in system parameters, engine controller, operating conditions, and mechanical loading on the induction motor. The approach used expands on a combined mechanical and thermodynamic formulation employed in a previous paper. The application of state-space technique and frequency domain analysis enhances understanding of the dynamic interactions. Engine-alternator parametric sensitivity studies, similar to those of the previous paper, are summarized. Detailed discussions are provided for parametric variations which relate to the engine controller and system operating conditions. The results suggest that the controllability of a FPSE-based power system is enhanced by proper operating conditions and built-in controls.

Kankam, M. David↗

Making the Grid "Smart" Through "Smart" Microgrids: Real-Time Power Management of Microgrids with Multiple Distributed Generation Sources Using Intelligent Control

In this Project we collaborated with two DOE National Laboratories, Pacific Northwest National Lab (PNNL) and Lawrence Berkeley National Lab (LBL). Dr. Hammerstrom of PNNL initially supported our project and was on the graduate committee of one of the Ph.D. students (graduated in 2014) who was supported by this project. He is also a committee member of a current graduate student of the PI who was supported by this project in the last two years (August 2014-July 2016). The graduate student is now supported be the Electrical and Computer Engineering (ECE) Department at Montana State University (MSU). Dr. Chris Marney of LBL provided actual load data, and the software WEBOPT developed at LBL for microgrid (MG) design for our project. NEC-Labs America, a private industry, also supported our project, providing expert support and modest financial support. We also used the software “HOMER,” originally developed at the National Renewable Energy Laboratory (NREL) and the most recent version made available to us by HOMER Energy, Inc., for MG (hybrid energy system) unit sizing. We compared the findings from WebOpt and HOMER and designed appropriately sized hybrid systems for our case studies. The objective of the project was to investigate real-time power management strategies for MGs using intelligent control, considering maximum feasible energy sustainability, reliability and efficiency while, minimizing cost and undesired environmental impact (emissions). Through analytic and simulation studies, we evaluated the suitability of several heuristic and artificial-intelligence (AI)-based optimization techniques that had potential for real-time MG power management, including genetic algorithms (GA), ant colony optimization (ACO), particle swarm optimization (PSO), and multi-agent systems (MAS), which is based on the negotiation of smart software-based agents. We found that PSO and MAS, in particular, distributed MAS, were more efficient and better suited for our work. We investigated the following: • Intelligent load control - demand response (DR) - for frequency stabilization in islanded MGs (partially supported by PNNL). • The impact of high penetration of solar photovoltaic (PV)-generated power at the distribution level (partially supported by PNNL). • The application of AI approaches to renewable (wind, PV) power forecasting (proposed by the reviewers of our proposal). • Application of AI approaches and DR for real-time MG power management (partially supported by NEC Labs-America) • Application of DR in dealing with the variability of wind power • Real-time MG power management using DR and storage (partially supported by NEC Labs-America) • Application of DR in enhancing the performance of load-frequency controller • MAS-based whole-sale and retail power market design for smart grid A

24 POWER TRANSMISSION AND DISTRIBUTION↗

Carbon emission responsive building control: A case study with an all-electric residential community in a cold climate

In the United States, buildings account for 35% of total energy-related carbon dioxide emissions, making them important contributors to decarbonization. Carbon intensities in the power grid are time-varying and can fluctuate significantly within hours, so shifting building loads in response to the carbon intensities can reduce a building’s operational carbon emissions. This paper presents a rule-based carbon responsive control framework that controls the setpoints of thermostatically controlled loads responding to the grid’s carbon emission signals in real time. Based on this framework, four controllers are proposed with different combinations of carbon accounting methods and control rules. To evaluate their performance, we performed simulation studies using models of a 27-home, all-electric, net zero energy residential community located in Basalt, Colorado, United States. The carbon intensity data of four future years from the Cambium data set are adopted to account for the evolving resource mix in the power grid. Various performance metrics, including energy consumption, carbon emission, energy cost, and thermal discomfort, were used to evaluate the performance of the controllers. Sensitivity analysis was also conducted to determine how the control thresholds and intervals affect the controllers’ performance. Simulation results indicate that the carbon responsive controllers can reduce the homes’ annual carbon emissions by 6.0% to 20.5%. However, the energy consumption increased by 0.9% to 6.7%, except in one scenario where it decreased by 2.2%. Compared to the baseline, the change in energy cost was between –2.9% and 3.4%, and thermal discomfort was also maintained within an acceptable range. The little impact on energy cost and thermal discomfort indicates there are no potential roadblocks for customer acceptance when rolling out the controllers in utility programs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Control of multiple resonant power processors in a multi-source system

Analysis and test results show that phasor-regulated, Mapham-derived resonant inverters can be paralleled to provide standardizing interfaces for multiple sources on a utility-type, aerospace power distribution bus. The basic sources do not require matching in any way, and may have grossly different characteristics. Fully stable system architectures with multiple sources, parallel/redundant distribution buses, and a wide variety of loads can be easily constructed and controlled. The commands and parameters available for system control allow for tight tolerance bus voltage control, and absolute power-sharing control from the various sources over the full range of possible source and load variations. That level of control enables simplified load power processing hardware and the distribution of losses to optimally load the source thermal control system. Positive control of all system performance and allocation of losses are not required by all missions or vehicles, and overall vehicle considerations do not always require the loads on vehicle energy sources and thermal control systems to be balanced. In those cases, power system control can be simplified, and a hierarchical set of defaults can be substituted for computer-generated or supervisory input commands to allow for stable, fully autonomous system operation.

Mildice, James↗

Investigation and Feasibility Assessment of TOPAZ-2 Derivations for Space Power Applications

The ability to provide continuous power at significant levels is of utmost importance for many space missions, from simple satellite operations to manned Mars missions. One of the main problems faced in delivering solar or chemical space power in the tens of kW range, is the increasingly massive nature of the power source and the costs associated with its launch, operation and maintenance. A national program had been initiated to study the feasibility of using certain advanced technologies in developing an efficient lightweight space power source. The starting point for these studies has been the Russian TOPAZ-2 space reactor system, with the ultimate goal to aid in the development of a TOPAZ-2 derivative which will be ready for flight by the year 2000. The main objective of this project has been to perform feasibility assessment and trade studies which would allow the development of an advanced space nuclear power system based on the in-core thermionic fuel element technology currently used in the Russian TOPAZ-2 reactor. Two of the important considerations in developing the concept are: (1) compliance of the current TOPAZ-2 and of any advanced designs with U.S. nuclear safety expectations, and (2) compliance of the design with the seven years lifetime requirement. The project was composed of two major phases. The initial phase of the project has concentrated on understanding the TOPAZ-2 thermionic reactor in sufficient detail to allow several follow-on tasks. The primary interest during this first phase has been given on identifying the potential of the TOPAZ-2 design for further improvements. The second phase of the project has focused on the feasibility of a TOPAZ-2 system capable of delivering 30-50 kWe. Towards the elimination of single-point failures in the load voltage regulation system an active voltage regulator has been designed to be used in conjunction with the available shunt load voltage regulator. The possible use of a dual-loop, model-based adaptive control system for load-following in the TOPAZ-2 has also been investigated. The objective of this fault-tolerant, autonomous control system is to deliver the demanded electric power at the desired voltage level, by appropriately manipulating the neutron power through the control drums. As a result, sufficient thermal power is produced to meet the required demand in the presence of dynamically changing system operating conditions and potential sensor failures. The designed controller is proposed for use in combination with the currently available shunt regulators, or as a back-up controller when other means of power system control, including some of the sensors, fail.

Parlos, Alexander G.↗

Docking mechanism for spacecraft

A system is presented for docking a space vehicle to a space station where a connecting tunnel for in-flight transfer of personnel is required. Cooperable coupling mechanisms include docking rings on the space vehicle and space station. The space station is provided with a tunnel structure, a retraction mechanism, and a docking ring. The vehicle coupling mechanism is designed to capture the station coupling mechanism, arrest relative spacecraft motions while limiting loads to acceptable levels, and then realign the spacecraft for final docking and tunnel interconnection. The docking ring of the space vehicle coupling mechanism is supported by linear attentuator actuator devices, each of which is controlled by a control system which receives loading information signals and attenuator stroke information signals from each device and supplies output signals for controlling its linear actuation to attenuate impact loading or to realign the spacecraft for final docking and tunnel interconnection. The retraction mechanism is used to draw the spacecraft together after initial contact and coupling. Tunnel trunnions, cooperative with the latches on the space vehicle constitute the primary structural tie between the spacecraft in final docked configuration.

Lange, Gregory A.↗

Buffet Load Alleviation

High performance aircraft are, by their very nature, often required to undergo maneuvers involving high angles of attack. Under these conditions unsteady vortices emanating from the wing and the fuselage will impinge on the twin fins (required for directional stability) causing excessive buffet loads, in some circumstances, to be applied to the aircraft. These loads result in oscillatory stresses, which may cause significant amounts of fatigue damage. Active control is a possible solution to this important problem. A full-scale test was carried out on an F/A-18 fuselage and fins using piezoceramic actuators to control the vibrations. Buffet loads were simulated using very powerful electromagnetic shakers. The first phase of this test was concerned with the open loop system identification whereas the second stage involved implementing linear time invariant control laws. This paper looks at some of the problems encountered as well as the corresponding solutions and some results. It is expected that flight trials of a similar control system to alleviate buffet will occur as early as 2001.

Ryall, T. G.↗

Predicting plug loads with occupant count data through a deep learning approach

Predictive control has gained increasing attention for its ability to reduce energy consumption and improve occupant comfort in buildings. The plug loads prediction is a key component for the predictive building controls, as plug loads is a major source of internal heat gains in buildings. This study proposed a novel method to apply the Long-Short-Term-Memory (LSTM) Network, a special form of Recurrent Neural Network, to predict plug loads. The occupant count and the time have been confirmed to drive the plug load profile and thus selected as the features for the plug load prediction. The LSTM network was trained and tested with ground truth occupant count data collected from a real office building in Berkeley, California. Results from the LSTM network markedly improve the prediction accuracy compared with traditional linear regression methods and the classical Artificial Neural Network. 95% of 1-hour predictions from LSTM network are within ±1 kW of the actual plug loads, given the average plug loads during the office hour is 8.6 kW. The CV(RMSE) of the predicted plug load is 11% for the next hour, and 20% for the next eight hours. Lastly, we compared four prediction approaches with the office building we monitored: LSTM vs. ARIMA, with occupant counts vs. without occupant counts. It was found, the prediction error of the LSTM approach is around 4% less than the ARIMA approach. Using occupant counts as an exogenous input could further reduce the prediction error by 5%-6%. The findings of this paper could shed light on the plug load prediction for building control optimizations such as model-predictive control.

Occupant count↗

Performance Evaluation of Distributed Energy Resources Management System via Advanced Hardware-in-the-Loop Simulation: Preprint

This paper presents an advanced hardware-in-the-loop (HIL) platform to evaluate the performance of voltage regulation coordinated across advanced distribution management systems (ADMS), distributed energy management system (DERMS), and DERs. The HIL platform provides realistic laboratory testing, including accurate modeling of the real-world distribution system from a utility partner, real controller (ADMS and DERMs) and power (DERs) hardware, and standard communications protocols. The test results show proper functionalities of the integrated platform and performance of the peak load management of coordinated control systems. Based on the laboratory testing, the utility can set up the same grid automation system to manage DERs to achieve system-level control and operation objectives (e.g., peak load management), thus derisking potential issues (e.g., instability) for field deployment.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Multi-Agent Reinforcement Learning for Distribution System Critical Load Restoration

Grid resilience has become a critical topic recently because of the increasing occurrence of extreme events and the growing integration of intermittent renewable energy sources. To build a resilient distribution system, this paper develops a multiagent reinforcement learning-based (MARL) method to coordinate distribution energy resources (DERs) dispatch, load pickup, and network reconfiguration for load restoration after a system outage. With the help of two types of control agents, namely critical load restoration (CLR) and coordination (COR) agents, system loads can be restored efficiently, given available resources. The effectiveness and superiority of the proposed algorithm are demonstrated through simulations and comparative studies on a real distribution feeder in Western Colorado.

distribution system↗

Heila Microgrid Controller Validation Using CUBE: Cooperative Research and Development Final Report, CRADA Number CRD-17-663

This CRADA facilitates validation of the Heila IQ controller (microgrid controller) using NREL's Consolidated Utility Base Energy (CUBE) hardware platform. The CUBE microgrid platform includes power electronics and controls to integrate PV, battery, and diesel generator assets to serve a common load. The Heila IQ controller includes algorithms to manage and optimize these assets and will be used as the dispatch-level controller for the CUBE. Heila will use the CUBE platform in a number of use cases that will benefit commercialization of the Heila IQ controller.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Multi-Agent Reinforcement Learning for Distribution System Critical Load Restoration: Preprint

Grid resilience has become a critical topic recently because of the increasing occurrence of extreme events and the growing integration of intermittent renewable energy sources. To build a resilient distribution system, this paper develops a multi-agent reinforcement learning-based (MARL) method to coordinate distribution energy resources (DERs) dispatch, load pickup, and network reconfiguration for load restoration after a system outage. With the help of two types of control agents, namely critical load restoration (CLR) and coordination (COR) agents, system loads can be restored efficiently, given available resources. The effectiveness and superiority of the proposed algorithm are demonstrated through simulations and comparative studies on a real distribution feeder in Western Colorado.

distribution system↗

Plant Operation and Control Strategy for the PGSFR

The plant operating strategy and control system design for the PGSFR plant are being developed to meet functional and design requirements for the plant. The functional requirements are derived from the mission of the reactor while the design requirements are related to the reactor technologies that underlie the PGSFR. This paper describes the operation and control strategy developed to meet these requirements and the implementation of that strategy. Representative results are presented for the dynamic behavior of the nuclear steam supply system (NSSS) during operational transients. A supervisory control system has been designed for the PGSFR for Startup, Reactor Leading, and Load Following modes and it performance assessed for operational transients in the Load Following mode. The control system extends into the balance of plant to include regulation of turbine inlet pressure and steam generator pressure and includes a feedwater pump with prototypic operating characteristics. The results indicate a very stable plant response with minimal deviation from quasi-static conditions for the transients simulated. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Description of the Prometheus Program Alternator/Thruster Integration Laboratory (ATIL)

The Project Prometheus Alternator Electric Thruster Integration Laboratory's (ATIL) primary two objectives are to obtain test data to influence the power conversion and electric propulsion systems design, and to assist in developing the primary power quality specifications prior to system Preliminary Design Review (PDR). ATIL is being developed in stages or configurations of increasing fidelity and complexity in order to support the various phases of the Prometheus program. ATIL provides a timely insight of the electrical interactions between a representative Permanent Magnet Generator, its associated control schemes, realistic electric system loads, and an operating electric propulsion thruster. The ATIL main elements are an electrically driven 100 kWe Alternator Test Unit (ATU), an alternator controller using parasitic loads, and a thruster Power Processing Unit (PPU) breadboard. This paper describes the ATIL components, its development approach, preliminary integration test results, and current status.

Baez, Anastacio N.↗

Rapid Load Transition for Integrated Solid Oxide Fuel Cell - Gas Turbine (SOFC-GT) Energy Systems: A Demonstration of the Potential for Grid Response

Rapid load transition is an essential requirement for integrated energy systems to maintain grid resilience as more renewable resources are added to the grid. Integrated solid oxide fuel cell - gas turbine (SOFC-GT) systems can provide high efficiency and low carbon emissions over a broad range of turndown. These hybrids also have the potential to enable rapid grid response. The challenge has been to demonstrate effective control strategies to manage load transitions. In the present study, a load transition of ~50% was achieved in 10 s using a novel but simple strategy. Power demand on the SOFC and the GT were ramped down concurrently. During this transition, the SOFC anode fuel was manipulated to maintain SOFC fuel utilization while the cathode inlet air flow and temperature were also manipulated to thermally protect the SOFC. This study was conducted using the Hybrid Performance (Hyper) facility at the National Energy Technology Laboratory (NETL) in a co-simulation environment with the Idaho National Laboratory (INL)'s grid-simulation. The load ramping strategy was tested using a hardware-based cyber-physical simulation methodology. The results demonstrate a high-fidelity representation of SOFC-GT hybrid dynamics and validation of the control strategy. Thermal and electrochemical transients indicated that the SOFC was well protected during rapid load turndown without violating operability constraints. This demonstration revealed the non-linear nature of tightly coupled SOFC-GT system components, especially the non-linear response of SOFC cathode air flow and inlet temperature controls. These results highlight the needs and challenges in developing adaptive automatic controls for autonomous rapid load transitions. This work demonstrates that SOFC-GT hybrids are a viable option to provide the fast-ramping characteristics essential to accommodate high levels of variable renewable power while maintaining grid resilience, reliability, and environmental performance. The results also demonstrate the utility of co-simulation in advancing the tightly-coupled integrated energy systems needed to meet goals for zero-carbon power generation.

DIRECT ENERGY CONVERSION,POWER TRANSMISSION AND DI↗

Skeletal Phenotype of Transgenic Mice Expressing the Beta1 Integrin Cytoplasmic Tail In Osteoblasts

To define the physiologic role of beta1 integrin in bone formation and mechanical loading, transgenic mice were generated by expressing the cytoplasmic tall and transmembrane domain of Beta1 integrin under the control of the osteocalcin promoter. In cultured cells, this truncated fragment of Beta1 can act as a dominant negative. Previously, the matrix of calvariae was shown to be abnormal in transgenic (TG) compared to wildtype (WT) mice. In this study, we analyzed appendicular bone in TG and WT, male and female mice at 14, 35, 63, 90 and 365 days old (n=8-12/gp). To assess beta1 integrin function in mechanical loading, a pilot study using hindlimb unloading by tail suspension was performed. 35d old TG and WT females were hindlimb unloaded for 4 wks (n=3-5). Body mass, bone mineral content, histomorphometric (distal femur) and biomechanical parameters were analyzed. Statistical significance (P less than.05) was defined by ANOVA using the Tukey-Kramer post-hoc test. We confirmed transgene expression by immunoprecipitating then immunoblotting bone lysates using an antibody against the beta1 tail. Body masses of TG mice at 63, 90 and 365d old were greater (16-25%) than WT. Some TG female mice at 365d appeared obese; mean abdominal fat mass was 415% greater in TG than WT mice. Tibiae were longer (5-7%) in TG than WT mice at 63 and 90d. Tibial mineral mass of 35d males was 7% lower in TG than WT mice, but at 63d was 21% higher. The % osteoblast surface in 35d TG mice was 20% higher than WT, and at 63d was 17% lower, while % osteoclast surface did not differ. In 365d mice, cancellous bone volume (125%) and endocortical mineral apposition rate (40%) were greater in TG than WT males but not females. In WT mice, hindlimb unloading caused a reduction in mineral mass of tibiae (-20%) and lumbar vertebrae (-22%) relative to normally loaded controls. Surprisingly, hindlimb unloading also caused a relative reduction (-13%) in humerus mass. The effects of hindlimb unloading on tibia and humerus mass were less obvious in TG than in WT mice. Since hindlimb unloading caused skeletal changes in both loaded and unloaded bones, systemic changes may contribute to bone responses observed using this animal model. In conclusion, transgene expression resulted in marked metabolic changes during growth and in the aged female. Our results demonstrate that expression of the Beta1 integrin cytoplasmic tail in vivo causes gender- and age-specific changes in select morphometric parameters, bone length, and bone mass.

Globus, R. K.↗

Control and Scaling Approach for the Emulation of Dynamic Subscale Torque Loads

Research and development of electrified aircraft propulsion powertrains are relying on the use of electromechanical systems to emulate turbomachinery/rotor loads. Replacing a physical turbomachinery/rotor with a model driving a subscale electromechanical system capable of emulating subscale torque loads and responses is a lower risk, lower cost alternative to using the full-scale turbomachinery/rotor for initial control system verification. This paper outlines a novel control and scaling approach for emulating dynamic subscale torque loads using electric machine (EM) hardware for electrified aircraft propulsion research and development purposes. The approach, known as the Sliding Mode Impedance Controller with Scaling (SMICS), drives a mechanically coupled, two-EM system to behave like a subscale hardware representation of a hybrid-electric turbomachinery shaft. One EM reflects the inertial dynamics and torque load of the subscale turbomachinery under steady-state and transient operation while the second EM represents a motor/generator connected to the shaft, which is intended to hybridize the turbomachinery. This closed loop control and scaling algorithm applies impedance and sliding mode control schemes, along with parameter scaling, to match subscale, desired dynamics in real-time and to allow this system to be driven by a full-scale hybrid-electric turbomachinery model and control. The paper elaborates on the concept of the closed loop control and scaling approach and explains the significance of using impedance and sliding mode control. It shows a derivation of the closed loop control and scaling algorithm, its implementation, and presents a comparison of theoretical and actual simulation results acquired during hardware-in-the-loop testing of a partial turboelectric propulsion concept aircraft at the NASA Electric Aircraft Testbed (NEAT).The results show that the intended dynamic responses of the hardware and the aircraft model are achieved in both the time and frequency domain. Full scale propulsion control systems can be tested using this hardware and software approach.

Emulation↗

Historical review of C-5A lift distribution control systems

Analytical and experimental development work on various load alleviation systems for the C-5A is reviewed to trace the development of the technical and hardware concepts to the present time. Variations in system objectives, means of implementation and effects on loads and airplane performance, stability and control are discussed.

Disney, T. E.↗