Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “imaging systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

X-Ray Computed Tomography Monitors Damage in Composites

The NASA Lewis Research Center recently codeveloped a state-of-the-art x-ray CT facility (designated SMS SMARTSCAN model 100-112 CITA by Scientific Measurement Systems, Inc., Austin, Texas). This multipurpose, modularized, digital x-ray facility includes an imaging system for digital radiography, CT, and computed laminography. The system consists of a 160-kV microfocus x-ray source, a solid-state charge-coupled device (CCD) area detector, a five-axis object-positioning subassembly, and a Sun SPARCstation-based computer system that controls data acquisition and image processing. The x-ray source provides a beam spot size down to 3 microns. The area detector system consists of a 50- by 50- by 3-mm-thick terbium-doped glass fiber-optic scintillation screen, a right-angle mirror, and a scientific-grade, digital CCD camera with a resolution of 1000 by 1018 pixels and 10-bit digitization at ambient cooling. The digital output is recorded with a high-speed, 16-bit frame grabber that allows data to be binned. The detector can be configured to provide a small field-of-view, approximately 45 by 45 mm in cross section, or a larger field-of-view, approximately 60 by 60 mm in cross section. Whenever the highest spatial resolution is desired, the small field-of-view is used, and for larger samples with some reduction in spatial resolution, the larger field-of-view is used.

Baaklini, George Y.↗

A microwave tomography system using a tunable mirror for beam steering

Microwave tomography is a fast-growing technique in the fields of NDE and medical industry. This paper presents a new microwave tomography system which reduces the complexities of conventional microwave imaging systems by utilizing a reconfigurable mirror, a tunable reflectarray antenna. In order to build a tunable reflectarray with beam steering capabilities, the unit cell characteristics should dynamically alter. Modelling and experimental results of a single unit cell are presented in this work.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Multiwavelength study of OT 081: broadband modelling of a transitional blazar

ABSTRACT OT 081 is a well-known, luminous blazar that is remarkably variable in many energy bands. We present the first broadband study of the source, which includes very high energy (VHE, $E\gt $ 100 GeV) $\gamma$-ray data taken by the MAGIC (Major Atmospheric Gamma-ray Imaging Cherenkov telescopes) and H.E.S.S. (High Energy Stereoscopic System) imaging Cherenkov telescopes. The discovery of VHE $\gamma$-ray emission happened during a high state of $\gamma$-ray activity in July 2016, observed by many instruments from radio to VHE $\gamma$-rays. We identify four states of activity of the source, one of which includes VHE $\gamma$-ray emission. Variability in the VHE domain is found on daily time-scales. The intrinsic VHE spectrum can be described by a power law with index $3.27\pm 0.44_{\rm stat}\pm 0.15_{\rm sys}$ (MAGIC) and $3.39\pm 0.58_{\rm stat}\pm 0.64_{\rm sys}$ (H.E.S.S.) in the energy range of 55–300 and 120–500 GeV, respectively. The broadband emission cannot be successfully reproduced by a simple one-zone synchrotron self-Compton model. Instead, an additional external Compton component is required. We test a lepto-hadronic model that reproduces the data set well and a proton-synchrotron-dominated model that requires an extreme proton luminosity. Emission models that are able to successfully represent the data place the emitting region well outside of the broad-line region to a location at which the radiative environment is dominated by the infrared thermal radiation field of the dusty torus. In the scenario described by this flaring activity, the source appears to be a flat spectrum radio quasar (FSRQ), in contrast with past categorizations. This suggests that the source can be considered to be a transitional blazar, intermediate between BL Lac and FSRQ objects.

Abe, H.↗

Hybrid x-ray/optical luminescence imaging: Characterization of experimental conditions

Purpose: The feasibility of x-ray luminescence imaging is investigated using a dual-modality imaging system that merges x-ray and optical imaging. This modality utilizes x-ray activated nanophosphors that luminesce when excited by ionizing photons. By doping phosphors with lanthanides, which emit light in the visible and near infrared range, the luminescence is suitable for biological applications. This study examines practical aspects of this new modality including phosphor concentration, light emission linearity, detector damage, and spectral emission characteristics. Finally, the contrast produced by these phosphors is compared to that of x-ray fluoroscopy. Methods: Gadolinium and lanthanum oxysulfide phosphors doped with terbium (green emission) or europium (red emission) were studied. The light emission was imaged in a clinical x-ray scanner with a cooled CCD camera and a spectrophotometer; dose measurements were determined with a calibrated dosimeter. Using these properties, in addition to luminescence efficiency values found in the literature for a similar phosphor, minimum concentration calculations are performed. Finally, a 2.5 cm agar phantom with a 1 cm diameter cylindrical phosphor-filled inclusion (diluted at 10 mg/ml) is imaged to compare x-ray luminescence contrast with x-ray fluoroscopic contrast at a superficial location. Results: Dose to the CCD camera in the chosen imaging geometry was measured at less than 0.02 cGy/s. Emitted light was found to be linear with dose (R{sup 2}=1) and concentration (R{sup 2}=1). Emission peaks for clinical x-ray energies are less than 3 nm full width at half maximum, as expected from lanthanide dopants. The minimum practical concentration necessary to detect luminescent phosphors is dependent on dose; it is estimated that subpicomolar concentrations are detectable at the surface of the tissue with typical mammographic doses, with the minimum detectable concentration increasing with depth and decreasing with dose. In a reflection geometry, x-ray luminescence had nearly a 430-fold greater contrast to background than x-ray fluoroscopy. Conclusions: X-ray luminescence has the potential to be a promising new modality for enabling molecular imaging within x-ray scanners. Although much work needs to be done to ensure biocompatibility of x-ray exciting phosphors, the benefits of this modality, highlighted in this work, encourage further study.

60 APPLIED LIFE SCIENCES↗

Balancing dose and image registration accuracy for cone beam tomosynthesis (CBTS) for breast patient setup

Purpose: To balance dose reduction and image registration accuracy in breast setup imaging. In particular, the authors demonstrate the relationship between scan angle and dose delivery for cone beam tomosynthesis (CBTS) when employed for setup verification of breast cancer patients with surgical clips. Methods: The dose measurements were performed in a female torso phantom for varying scan angles of CBTS. Setup accuracy was measured using three registration methods: Clip centroid localization accuracy and the accuracy of two semiautomatic registration algorithms. The dose to the organs outside of the ipsilateral breast and registration accuracy information were compared to determine the optimal scan angle for CBTS for breast patient setup verification. Isocenter positions at the center of the patient and at the breast-chest wall interface were considered. Results: Image registration accuracy was within 1 mm for the CBTS scan angles {theta} above 20 deg. for some scenarios and as large as 80 deg. for the worst case, depending on the imaged breast and registration algorithm. Registration accuracy was highest based on clip centroid localization. For left and right breast imaging with the isocenter at the chest wall, the dose to the contralateral side of the patient was very low (<0.5 cGy) for all scan angles considered. For central isocenter location, the optimal scan angles were 30 deg. - 50 deg. for the left breast imaging and 40 deg. - 50 deg. for the right breast imaging, with the difference due to the geometric asymmetry of the current clinical imaging system. Conclusions: The optimal scan angles for CBTS imaging were found to be between 10 deg. and 50 deg., depending on the isocenter location and ipsilateral breast. Use of the isocenter at the breast-chest wall locations always resulted in greater accuracy of image registration (<1 mm) at smaller angles (10 deg. - 20 deg.) and at lower doses (<0.1 cGy) to the contralateral organs. For chest wall isocenters, doses delivered to organs outside of the target breast were much smaller than the scattered and leakage doses of the treatment beams. The complete volumetric information of all clips in the region of interest, combined with the small dose to the contralateral organs and the small scan angle, could result in an advantage for small angle CBTS with off center isocenters over simple orthogonal pairs.

60 APPLIED LIFE SCIENCES↗

Modeling an Interwoven Collimator for A 3D Endocavity Gamma Camera

Positron emission tomography (PET) and single-photon emission-computed tomography (SPECT) are important nuclear-medical imaging tools in diagnosing cancers and creating effective treatment plans. Here, commercially imaging systems are operated externally and can create 3D images of the whole body or of specific organs by rotating the gamma-ray detectors, and then employing software to reconstruct the 3D images from the multiple 2D projections at different angles of view.

36 MATERIALS SCIENCE↗

Interplanetary optical navigation using Charge Coupled Devices

Charge Coupled Devices (CCD) will be used as optical navigation image detectors in space missions planned for the 1980's. This paper presents analyses directed at assessing the performance of an imaging system employing a CCD (i.e., a solid state imager (SSI)), for a Jovian satellite tour environment. CCD operating principles are summarized and methods of calculating theoretical dynamic range presented. Methods of analyzing the SSI's ability to perform the fundamental optical navigation function of imaging a target body and one or more stars, are presented. This capability is expressed as a function of SSI optical and electronic parameters and of astrophysical parameters. The influence of these factors and pointing control errors on navigation picture budgets is analyzed. The effect of the sun's glare is analyzed from the standpoint of its reduction of SSI dynamic range and increase of navigation picture budget. Radiation effects on SSI navigation imaging performance are discussed and a method of analyzing probabilities of distinguishing real from false stars presented.

Davis, R. P.↗

Infrared Imagery of Shuttle (IRIS). Task 1, summary report

The feasibility of remote, high-resolution infrared imagery of the Shuttle Orbiter lower surface during entry to obtain accurate measurements of aerodynamic heat transfer was demonstrated. Using available technology, such images can be taken from an existing aircraft/telescope system (the C141 AIRO) with minimum modification or addition of systems. Images with a spatial resolution of 1 m or better and a temperature resolution of 2.5% between temperatures of 800 and 1900 K can be obtained. Data reconstruction techniques can provide a geometrically and radiometrically corrected array on addressable magnetic tape ready for display by NASA.

Chocol, C. J.↗

Spaceborne and airborne imaging radar observations of sand dunes

An assessment of the ability of orbital synthetic aperture radar (SAR) imaging systems to provide useful information about aeolian features, and to determine how such a system might be constrained by the need to image these features, is presented. Seasat and aircraft radar imagery of five areas of sand dunes are studied, and compared to Landsat imagery and air photos, for two wavelengths (3.0 and 23.5 cm) and incidence angles ranging from 0 to 70 deg. It is shown that the illumination direction of the radar beam is important, since directional dune features must be oriented within 60 deg of perpendicular to the radar illumination direction in order to be imaged. It is concluded that the availability of radar imagery for two directions greatly facilitates interpretation of dune morphology and derivation of conclusions about causative wind regimes.

Blom, R.↗

Programmable scan/read circuitry for charge coupled device imaging detectors

A circuit for scanning and outputting the induced charges in a solid state charge coupled device (CCD) image detector is disclosed in an image detection system for use in a spacecraft attitude control system. The image detection system includes timing control circuitry for selectively controlling the output of the CCD detector so that video outputs are provided only with respect to induced charges corresponding to predetermined sensing element lines of the CCD detector. The timing control circuit and the analog to digital converter are controlled by a programmed microprocessor which defines the video outputs to be converted and further controls the timing control circuit so that no video outputs are provided during the delay associated with analog to digital conversion.

Salomon, P. M.↗

Image understanding and interpretation in microwave diversity imaging

The authors investigate microwave imaging of metallic objects using a diversity method and interpret and predict the reconstructed image from an approach based on analysis of the scattering mechanism and a back-projection algorithm used in image retrieval. The connection between the various scattering mechanisms and the reconstructed images is discussed, what the images represent is interpreted, and a prediction is made as to what the image will look like over given spectral and angular windows. A brief description is given of the microwave diversity imaging system and the formulation of the microwave diversity imaging based on the physical optics approximation. The scattering mechanism of a complex shaped metallic object is then briefly reviewed and an alternate approach to interpreting the reconstructed image based on the understanding of the scattering mechanism and the reconstruction algorithm is given. Several numerical and experimental examples are included to support this interpretation approach.

Li, Hsueh-Jyh↗

Advanced NDE research in electromagnetic, thermal, and coherent optics

A new inspection technology called magneto-optic/eddy current imaging was investigated. The magneto-optic imager makes readily visible irregularities and inconsistencies in airframe components. Other research observed in electromagnetics included (1) disbond detection via resonant modal analysis; (2) AC magnetic field frequency dependence of magnetoacoustic emission; and (3) multi-view magneto-optic imaging. Research observed in the thermal group included (1) thermographic detection and characterization of corrosion in aircraft aluminum; (2) a multipurpose infrared imaging system for thermoelastic stress detection; (3) thermal diffusivity imaging of stress induced damage in composites; and (4) detection and measurement of ice formation on the space shuttle main fuel tank. Research observed in the optics group included advancements in optical nondestructive evaluation (NDE).

Skinner, S. Ballou↗

Preliminary design of a satellite observation system for Space Station Freedom

Degobah Satellite Systems (DSS), in cooperation with the University Space Research Association (USRA), NASA - Johnson Space Center (JSC), and the University of Texas, has completed the preliminary design of a satellite system to provide inexpensive on-demand video images of all or any portion of Space Station Freedom (SSF). DSS has narrowed the scope of the project to complement the work done by Mr. Dennis Wells at Johnson Space Center. This three month project has resulted in completion of the preliminary design of AERCAM, the Autonomous Extravehicular Robotic Camera, detailed in this design report. This report begins by providing information on the project background, describing the mission objectives, constraints, and assumptions. Preliminary designs for the primary concept and satellite subsystems are then discussed in detail. Included in the technical portion of the report are detailed descriptions of an advanced imaging system and docking and safing systems that ensure compatibility with the SSF. The report concludes by describing management procedures and project costs.

Cabe, Greg↗

Plant Chlorophyll Content Imager with Reference Detection Signals

A portable plant chlorophyll imaging system is described which collects light reflected from a target plant and separates the collected light into two different wavelength bands. These wavelength bands, or channels, are described as having center wavelengths of 700 nm and 840 nm. The light collected in these two channels is processed using synchronized video cameras. A controller provided in the system compares the level of light of video images reflected from a target plant with a reference level of light from a source illuminating the plant. The percent of reflection in the two separate wavelength bands from a target plant are compared to provide a ratio video image which indicates a relative level of plant chlorophyll content and physiological stress. Multiple display modes are described for viewing the video images.

Spiering, Bruce A.↗

Geodesy at Mercury with MESSENGER

In 2011 the MESSENGER (MErcury Surface, Space ENvironment, GEochemistry, and Ranging) spacecraft will enter Mercury orbit and begin the mapping phase of the mission. As part of its science objectives the MESSENGER mission will determine the shape and gravity field of Mercury. These observations will enable the topography and the crustal thickness to be derived for the planet and will determine the small libration of the planet about its axis, the latter critical to constraining the state of the core. These measurements require very precise positioning of the MESSENGER spacecraft in its eccentric orbit, which has a periapsis altitude as low as 200 km, an apoapsis altitude near 15,000 km, and a closest approach to the surface varying from latitude 60 to about 70 N. The X-band tracking of MESSENGER and the laser altimetry are the primary data that will be used to measure the planetary shape and gravity field. The laser altimeter, which has an expected range of 1000 to 1200 km, is expected to provide significant data only over the northern hemisphere because of MESSENGER's eccentric orbit. For the southern hemisphere, radio occultation measurements obtained as the spacecraft passes behind the planet as seen from Earth and images obtained with the imaging system will be used to provide the long-wavelength shape of the planet. Gravity, derived from the tracking data, will also have greater resolution in the northern hemisphere, but full global models for both topography and gravity will be obtained at low harmonic order and degree. The limiting factor for both gravity and topography is expected to be knowledge of the spacecraft location. Present estimations are that in a combined tracking, altimetry, and occultation solution the spacecraft position uncertainty is likely to be of order 10 m. This accuracy should be adequate for establishing an initial geodetic coordinate system for Mercury that will enable positioning of imaged features on the surface, determination of the planet's obliquity, and detection of the librational motion of the planet about its axis.

Smith, David E.↗

Interference-free ultrasound imaging during HIFU therapy, using software tools

Disclosed herein is a method for obtaining a composite interference-free ultrasound image when non-imaging ultrasound waves would otherwise interfere with ultrasound imaging. A conventional ultrasound imaging system is used to collect frames of ultrasound image data in the presence of non-imaging ultrasound waves, such as high-intensity focused ultrasound (HIFU). The frames are directed to a processor that analyzes the frames to identify portions of the frame that are interference-free. Interference-free portions of a plurality of different ultrasound image frames are combined to generate a single composite interference-free ultrasound image that is displayed to a user. In this approach, a frequency of the non-imaging ultrasound waves is offset relative to a frequency of the ultrasound imaging waves, such that the interference introduced by the non-imaging ultrasound waves appears in a different portion of the frames.

Vaezy, Shahram↗

Low Voltage Low Light Imager and Photodetector

Highly efficient, low energy, low light level imagers and photodetectors are provided. In particular, a novel class of Della-Doped Electron Bombarded Array (DDEBA) photodetectors that will reduce the size, mass, power, complexity, and cost of conventional imaging systems while improving performance by using a thinned imager that is capable of detecting low-energy electrons, has high gain, and is of low noise.

Nikzad, Shouleh↗

AIM: Ames Imaging Module Spacecraft Camera

The AIM camera is a small, lightweight, low power, low cost imaging system developed at NASA Ames. Though it has imaging capabilities similar to those of $1M plus spacecraft cameras, it does so on a fraction of the mass, power and cost budget.

IMAGING↗