Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “grid storage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

VPP Participation Models: What is the Objective?

Virtual power plants (VPPs) can provide grid services by aggregating and controlling many distributed energy resources. However, their design, operation, level of participation, and outcomes depend on the regulatory and market environments they operate in, DER owner preferences, grid service value, and technical capabilities (e.g., communications, forecasting, controls, user interfaces). Although VPPs are inherently complex, they could enable high shares of behind-the-meter solar plus storage and reduce the cost of electrifying, e.g., personal vehicles and space heating.

demand response↗

Accelerating Optimal Integration of Energy Efficiency Strategies with Industrialized Modular Construction: Preprint

The National Renewable Energy Laboratory's (NREL's) Industrialized Construction Innovation team first introduced the Industrialized Construction Assessment Framework to achieve affordable, net-zero energy (NZE) modular multifamily buildings in the 2020 ACEEE paper "Integrating Energy Efficiency Strategies with Industrialized Construction for our Clean Energy Future." Since then, NREL has continued to drive the ambitious plan to accelerate optimal integration of energy efficiency strategies during industrialized construction with little or no additional cost, labor, and production time. This follow-on paper introduces the Energy in Modular (EMOD) buildings method and presents NREL's research efforts over the last two years in collaboration with industry, including affordable housing partners. NREL has developed an idealized NZE modular multifamily building design that incorporates five energy efficiency strategies well suited for industrialized construction in factories: (1) envelope thermal control, (2) envelope infiltration control, (3) mechanical, electrical, and plumbing systems, (4) smart controls, and (5) solar plus storage. This paper highlights results from leveraging design for manufacturing and assembly principles, testing, and validation pilots with factory partners; demonstrating pod prototypes in test stand at NREL; and performing simulations. Overall, these research efforts address barriers to whole-building system integration, such as poor installation quality of thermal and air barriers; lack of unitized systems for space conditioning, energy recovery and ventilation, and water heating; problematic on-site installation, commissioning, and configuration of controls; and lack of cost-effective integration for grid-friendly design and emerging technologies. Conclusively, the paper delineates next steps for future work with NREL's partners toward developing a transformational pathway for our clean energy future.

affordable housing↗

Geographical variability of summer- and winter-dominant onshore wind

For each geographical region, one of the biggest challenges in reaching a zero-carbon grid is identifying sources of electricity that match the seasonal profile of the load. Summer-dominant solar electricity generation can often be balanced by winter-dominant wind electricity generation. Together with long-duration storage, balanced solar and wind generation are well positioned to provide reliable renewable electricity. However, in some locations the wind may not complement solar energy so well. For example, currently California's wind turbines produce more electricity during summer than winter, raising the question of whether all future wind plants in California will exhibit the same seasonality. As a response to this question, in this paper, we analyzed the generation from existing California wind plants and simulated potential onshore wind resource for the whole state using a metric that reflects the relative wind resource in winter. Our results indicate that the seasonality of the wind can vary for very small spatial difference with more than half of California showing stronger wind resource in the winter compared with the summer despite the current observation of the opposite trend. This study differentiates the seasonality of potential wind resources to inform the creation of a reliable, 100%-renewable-driven grid.

17 WIND ENERGY↗

Energy Storage Improves Power Plant Flexibility and Economic Performance

Most existing coal-fired power plants were designed for sustained operation at full load to maximize efficiency, reliability, and revenue, as well as to operate air pollution control devices at design conditions. Depending on plant type and design, these plants can adjust output within a fixed range in response to plant operating or market conditions. The need for flexibility driven by increased penetration of variable and non-dispatchable power generation, such as wind and solar, is shifting the traditional mission profile of thermoelectric power plants in three ways: more frequent shutdowns when market or grid conditions warrant, more aggressive load ramp rates (rate of output change), and a lower minimum sustainable load, which provides a wider operating range and helps avoid costly plant shutdowns. Recent studies have shown that the flexibility of a coal-fired power plant can be improved by energy storage. The objective of this work was to analyze a set of energy storage options and determine their impact on the flexibility and economics of a representative coal-fired power plant. The effect of three energy storage systems integrated with a coal power plant on plant flexibility and economics was investigated. The results obtained in this project show that energy storage systems integrated with a thermal power plant improve plant flexibility and participation in the energy and ancillary services markets, which improves plant financial performance.

20 FOSSIL-FUELED POWER PLANTS↗

Compressed Gas Energy Storage Integrated with Combined Heat and Power Plant

A new energy storage technology, Comrpessed Gas Energy Storage (CGES), seeks to achieve low-cost, long-duration eenrgy storage by combining mature commercially-available technology (compressors, high-pressure gas storage, expander generators) and utilizing existing infrastructure for transportation and distribution of industrial gases. CGES utilizes existing compressors to transform electricity into potential energy (pressure), existing pipelines or underground storage to store said potential energy, and adds new expander generators at pressure reduction points in the networkm to recover part of the energy used in compression and transform it into electricity. By adapting itself to widely available existing infrastructure, CGES recovers energy that is otherwise wasted in the gas value chain, reduces the cost of new facilities, and avoids many of the development huddles typically associated with other long-duration energy storage technologies (e.g., Compressed Air Energy Storage, CAES). This paper discusses the performance and economics associated with CGES as a standalone project and in combination with a thermal power plant, based on a concept for integration of the technology over an existing lateral pipeline transporting natural gas to an 85 MW combined heat and power plant that feeds power to a grid with increasing share of renewable power generation.

03 NATURAL GAS↗

Least-cost Optimal Distribution Grid Expansion (LODGE) v1

LODGE finds the least-cost portfolio of traditional distribution system upgrades to integrate new loads and behind-the-meter DERs in combination with advanced non-wire alternative (NWA) planning solutions, such as utility-owned storage and distributed PV. Working with a set of least-cost solutions per feeder/substation allows us to benchmark and compare techno-economic performance of different traditional and NWA planning solutions. An important aspect of the LODGE model is that it includes power flow operation constraints. This means that the least-cost planning solutions delivered by LODGE are technically feasible. Available projects in LODGE portfolio include: 1) feeder reconductoring; 2) transformers upgrades; 3) non-wire alternatives, such as strategic siting and sizing of storage and distributed PV; 4) voltage regulators.

Heleno, Miguel↗

Multiscale simulation of integrated energy system and electricity market interactions

Accelerating the deep decarbonization of the world's electric grids requires the coordination of complex energy systems and infrastructures across timescales from seconds to decades. Here, we present a new multiscale simulation framework that integrates process- and grid-centric modeling paradigms to better design, operate, and control integrated energy systems (IESs), which combine multiple technologies, in wholesale energy markets. Traditionally, IESs are analyzed with a process-centric paradigm such as levelized cost of electricity (LCOE) or annualized net revenue, ignoring important interactions with electricity markets. This framework explicitly models the complex interactions between an IES's bidding, scheduling, and control decisions and the energy market's clearing and settlement processes, while incorporating operational uncertainties. Through two case studies, we show the importance of understanding and quantifying complex resource-grid interactions. In case study 1, we demonstrate that optimized bidding from one resource shifts the profit distribution for all energy systems in the market. This result suggests new and more flexible IES technologies can disrupt the economics of all market participants, possibly leading to accelerated retirements of less flexible resources. Interestingly, the optimized bidding has little impact on grid-level aggregate statistics, such as total generation costs and renewable penetration rate. While aggregate modeling strategies may remain valid under some IES adoption scenarios for analysis focused on regional outcomes, direct comparisons of IES technologies at specific locations without considering these interactions may lead to misleading or incorrect conclusions. In case study 2, we consider the design and flexible operation of IESs that hybridize conventional generators with energy storage. Through a sensitivity analysis, we find that as the size of the storage system increases, the total number of start-ups for coal- and natural gas-based IESs reduced by 25% and 33.6%, and the total thermal generator ramping (i.e., mileage) reduced by 86.5% and 62.5%, respectively. This shows the primary benefit of storage may not be reduced operational costs (which do not change significantly) but fewer start-ups and less ramping, which may greatly simplify the design, operation, and control of carbon capture systems. The new modeling and optimization capabilities from this work enable the coupling of rigorous, dynamic process models with grid-level production cost models to quantitatively identify the nuanced interdependencies across these vast timescales that must be addressed to realize clean, safe, and secure energy production. Moreover, the proposed general multiscale simulation framework is applicable to all IES technologies and can be easily extended to consider other energy carriers (e.g., hydrogen, ammonia) and energy infrastructures (e.g., natural gas pipelines).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Virginia Energy Resiliency Study

The Virginia Energy Resilience Study (VERS) was conducted under the U.S. Department of Energy’s Renewables Advancing Community Energy Resilience (RACER) program to strengthen the ability of communities in Virginia to anticipate, withstand, and recover from electric grid disruptions. While the project did not fund construction, it delivered a comprehensive, community-centered framework for assessing energy resilience and produced actionable, site-specific solar-plus-storage designs to support future implementation.

14 SOLAR ENERGY↗

Decarbonization of Residential Building Energy Supply: Impact of Cogeneration System Performance on Energy, Environment, and Economics

Electrical and thermal loads of residential buildings present a unique opportunity for onsite power generation, and concomitant thermal energy generation, storage, and utilization, to decrease primary energy consumption and carbon dioxide intensity. This approach also improves resiliency and ability to address peak load burden effectively. Demand response programs and grid-interactive buildings are also essential to meet the energy needs of the 21st century while addressing climate impact. Given the significance of the scale of building energy consumption, this study investigates how cogeneration systems influence the primary energy consumption and carbon footprint in residential buildings. The impact of onsite power generation capacity, its electrical and thermal efficiency, and its cost, on total primary energy consumption, equivalent carbon dioxide emissions, operating expenditure, and, most importantly, thermal and electrical energy balance, is presented. The conditions at which a cogeneration approach loses its advantage as an energy efficient residential resource are identified as a function of electrical grid’s carbon footprint and primary energy efficiency. Compared to a heat pump heating system with a coefficient of performance (COP) of three, a 0.5 kW cogeneration system with 40% electrical efficiency is shown to lose its environmental benefit if the electrical grid’s carbon dioxide intensity falls below 0.4 kg CO 2 per kWh electricity.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Responsible Adoption of Artificial Intelligence (AI) in Electric Grid Operations

The future of the grid will be powered by AI—or undermined by it. Artificial intelligence is rapidly reshaping grid operations, improving fault detection, forecasting accuracy, and real-time optimization. As AI systems move closer to operational decision loops, however, they introduce new consequence pathways: expanded attack surfaces, model integrity risks, regulatory exposure, and human-automation challenges. This talk presents a consequence-driven framework for deploying AI responsibly in the electric grid. Attendees will gain practical strategies to strengthen resilience, boost reliability, and deploy AI securely — ensuring the grid of the future is not only smarter but safer.

25 - ENERGY STORAGE↗

Hawaii Threat Brief

The Digital Energy Transformation is redefining how power systems operate, integrating physical infrastructure with digital technologies to enhance efficiency, visibility, and resilience. For islanded and digitally modernizing systems like Hawai‘i’s, this shift presents both new opportunities and evolving challenges in cybersecurity, supply chain assurance, and environmental resilience. This brief provides an overview of critical infrastructure dependencies and systemic risks associated with increasing digital integration. It summarizes recent energy-sector threat activity and case studies that illustrate adversary tactics and supply chain vulnerabilities, and identifies pathways to strengthen resilience.

25 - ENERGY STORAGE↗

CRADA Number NFE-17-06866 with Active Energy Systems, Inc. (CRADA Final Report)

Cooperative Research and Development Agreement (CRADA) NFE-17-06866 between Oak Ridge National Laboratory (ORNL) and Active Energy Systems Inc. (AES) focused on studying and modeling a low cost, high efficiency energy storage technology. The successful development of low-cost, high-efficiency energy storage is a significant bottleneck in the implementation of intermittent renewable energy sources such as wind and solar. AES is a startup company developing a heat exchange technology to utilize a low-temperature phase change material (PCM). The work done under this CRADA explored this technology’s ability to augment a heat pump/heat engine device to convert electricity into thermal energy and vice versa, operating to complement the needs of the electric grid. Modeling, design and development of a prototype to prove the technology was successful, but current production economics and market demand make further exploration undesirable.

25 ENERGY STORAGE↗

BESSIE: Battery & Energy Storage Supply Chain Analysis, Mitigation Deployment, and Tools

Battery energy storage systems (BESS) and their associated power electronic interfaces are key components to delivering clean and more resilient energy, providing much-needed fast-ramping, emergency discharge, generation, and operations support to the electric grid. These services have grown to be invaluable over the past ten years and will soon be an irreplaceable element of energy delivery. The Idaho National Laboratory (INL) strives to address these challenges through a strategic approach to supply chain risk assessment and mitigation for BESS and related digital energy equipment through the BESSIE project under the Center for Securing Digital Energy Technology. Recognizing that decreasing dependence on a foreign supply chain will take significant time and investment, BESSIE’s focus is strategically addressing battery supply chain risks by pairing short-term steps to operate securely through today’s risks with long-term steps to shape the supply chain over the coming years.

25 ENERGY STORAGE↗

Outage Forecast-Based Preventative Scheduling Model for Distribution System Resilience Enhancement

Distribution system resilience enhancement is an important topic to ensure customers have access to power supply during extreme events. In fact, certain weather-related extreme events can be predicted ahead of time. Therefore, it is important to investigate how to predict grid outages using extreme weather forecasts, and how outage predictions can be incorporated into distribution system resilience enhancement. In this paper, a preventative scheduling model for distribution systems is proposed. The model targets at allocating resources, especially mobile responsive resources such as mobile backup generators and mobile energy storage systems, to prepare for an extreme event in the day-ahead context. To achieve efficient resource allocation and scheduling, a machine learning-based outage prediction module is developed to predict vulnerable or risky segments of the distribution system based on historical operating records and extreme weather event forecast. By integrating the outage prediction results into the scheduling model, optimal resource allocation can be derived to help distribution systems prepare for an upcoming event and improve resilience performance. A real distribution feeder in North Carolina, U.S. is used in the case study to validate the proposed approach.

distributed energy resources↗

Adoption of a token-based authentication model for the CMS Submission Infrastructure

The CMS Submission Infrastructure (SI) is the main computing resource provisioning system for CMS workloads. A number of HTCondor pools are employed to manage this infrastructure, which aggregates geographically distributed resources from the WLCG and other providers. Historically, the model of authentication among the diverse components of this infrastructure has relied on the Grid Security Infrastructure (GSI), based on identities and X509 certificates. In contrast, commonly used modern authentication standards are based on capabilities and tokens. The WLCG has identified this trend and aims at a transparent replacement of GSI for all its workload management, data transfer and storage access operations, to be completed during the current LHC Run 3. As part of this effort, and within the context of CMS computing, the Submission Infrastructure group is in the process of phasing out the GSI part of its authentication layers, in favor of IDTokens and Scitokens. The use of tokens is already well integrated into the HTCondor Software Suite, which has allowed us to fully migrate the authentication between internal components of SI. Additionally, recent versions of the HTCondor-CE support tokens as well, enabling CMS resource requests to Grid sites employing this CE technology to be granted by means of token exchange. After a rollout campaign to sites, successfully completed by the third quarter of 2022, the totality of HTCondor CEs in use by CMS are already receiving Scitoken-based pilot jobs. On the ARC CE side, a parallel campaign was launched to foster the adoption of the REST interface at CMS sites (required to enable token-based job submission via HTCondor-G), which is nearing completion as well. In this contribution, the newly adopted authentication model will be described. We will then report on the migration status and final steps towards complete GSI phase out in the CMS SI.

Pérez-Calero Yzquierdo, Antonio↗

Optimizing DER Deployment for Climate, Health, Resilience, and Energy Bill Benefits Using the REopt Model

Climate change, public health, and resilience to power outages are of critical concern to local governments, federal agencies, and the private sector, and are increasingly motivating investments in distributed energy resources (DERs). However, designing a solar-plus-storage system to co-optimize for climate, health, resilience, and energy bill benefits requires complex trade-offs. To address this need, the National Renewable Energy Laboratory has integrated climate and health impacts of grid-purchased electricity and on-site fuel consumption into the publicly-available REopt web tool and API - a techno-economic model that determines the cost-optimal DER system sizes and dispatch strategy. This presentation will provide an overview of the tool's methodology, datasets, and capabilities, including costing emissions into system sizing and dispatch and setting emissions reductions targets. Results of previous work will demonstrate the use of new emissions accounting capabilities by quantifying the impact of including climate and health costs on the optimal resilient microgrid configurations for a hospital, school, and warehouse across 14 U.S. cities.

climate↗

Ordovician-Cambrian Units: Hierarchical Evaluation of Geologic Carbon Storage Resource Estimates

The Indiana Geological and Water Survey (IGWS) led subtask 1.1 to assess the regional distribution and estimate the storage capacity of Ordovician-Cambrian stratigraphic units located within the partnership region. A comprehensive data set of wireline logs and petrophysical information was used to generate these interpretations. These data include core analysis for porosity and permeability, mercury injection capillary pressure (MICP), and existing well data including location and stratigraphic information. This report includes storage resource estimates (SREs) for three potential storage reservoirs(limestone and dolostone from the Upper Ordovician Trenton Limestone/Black River Group and equivalent units, the Middle Ordovician St. Peter Sandstone, and primary target reservoir rocks of the Lower Ordovician and Upper Cambrian Knox Supergroup and equivalent units) calculated using six methodologies: (1) a fixed value of porosity of 10 percent in all units evaluated; (2) a unique average porosity (per well) from wireline-derived porosity (neutron, sonic, and/or density porosity for each unit); (3) porosity values from core analysis; (4) a depth-dependent porosity model (Knox Supergroup only); (5) porosity based on a model based on petrophysical facies; and (6) SREs using National Energy Technology Laboratory’s CO2 Storage prospeCtive Resource Estimation Excel aNalysis (CO2-SCREEN beta V2). All methods used the same values for thickness for each unit. However, the areal extent of each assessment was limited by the data available for each method. Estimated volumes were calculated in 1-by-1 kilometer grid cells and summarized as county and total stratigraphic unit volumes. The resultant SREs mass are displayed using boxplots, which allow for comparing data statistics (mean values and variability) between methods. Differences observed in SRE results from the six methods are mainly attributable to differences in the data and conceptual models used to interpret or estimate porosity in each method. Based on this systematic variability between methods, it is inferred that methods 1, 4, and 6 are best used for regional-scale reconnaissance estimates of storage capacity while methods 2, 3, and 5 are more appropriate for local scales where more data is required. All estimates are data-density dependent and different methods require different amounts of data for reasonable assessments. ArcMap 10.5.1 software was used to portray SREs to help visualize spatial variance of estimates for each methodology, and more importantly, to highlight those areas having the greatest total storage potential estimates.

01 COAL, LIGNITE, AND PEAT↗