Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “graphite”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

Increased fracture toughness of graphite-epoxy composites through intermittent interlaminar bonding

Intermittent interlaminar bonding, which can lead to a large increase in the fracture surface area, was achieved through the introduction of thin perforated Mylar between the layers of a multi-layer continuous-filament graphite-epoxy composite. For the best optimum condition included in this study, fracture toughness was increased from about 100 kJ/sq m for untreated specimens to an average of about 500 kJ/sq m, while tensile strength dropped from 500 MPa to 400 MPa, and elastic modulus remained the same at about 75 GPa. An approximate analysis is presented to explain the observed improvement in toughness.

Felbeck, D. K.↗

Lubrication and wear mechanisms of polyimide-bonded graphite fluoride films subjected to low contact stress

The tribological properties of polyimide-bonded graphite fluoride films were studied with a pin-on-disk friction apparatus. A 440 C HT stainless steel rider with a 0.95 millimeter diameter flat area was slid against the film in order to achieve a light, closely controlled contact stress. A 1 kilogram load was applied to this flat to give a projected contact stress of 14 megapascals. Two stages of lubrication were operating. In the first stage, the film supported the load and the lubricating mechanism appeared to be the shear of a thin surface layer of the film between the rider and the bulk of the film. The second stage began after the original film was worn away, and the lubricating mechanism appeared to be the shear of very thin lubricant layers between the flat area on the rider and flat plateaus generated on the sandblasted asperities of the metallic substrate. The major difference between the lubricating mechanisms of the hemispherical and flat riders was that the flat wore through the film much more slowly than did the hemisphere.

Fusaro, R. L.↗

Stress analysis and buckling of J-stiffened graphite-epoxy panel

A graphite epoxy shear panel with bonded on J stiffeners was investigated. The panel, loaded to buckling in a picture frame shear test is described. Two finite element models, each of which included the doubler material bonded to the panel skin under the stiffeners and at the panel edges, were used to make a stress analysis of the panel. The shear load distributions in the panel from two commonly used boundary conditions, applied shear load and applied displacement, were compared with the results from one of the finite element models that included the picture frame test fixture.

Davis, R. C.↗

Space fabrication: Graphite composite truss welding and cap forming subsystems

An automated beam builder for the fabrication of space structures is described. The beam builder forms a triangular truss 1.3 meters on a side. Flat strips of preconsolidated graphite fiber fabric in a polysulfone matrix are coiled in a storage canister. Heaters raise the material to forming temperature then the structural cap section is formed by a series of rollers. After cooling, cross members and diagonal tension cords are ultrasonically welded in place to complete the truss. The stability of fabricated structures and composite materials is also examined.

Jenkins, L. M.↗

Evaluation of micron size carbon fibers released from burning graphite composites

Quantitative estimates were developed of micron carbon fibers released during the burning of graphite composites. Evidence was found of fibrillated particles which were the predominant source of the micron fiber data obtained from large pool fire tests. The fibrillation phenomena were attributed to fiber oxidation effects caused by the fire environment. Analysis of propane burn test records indicated that wind sources can cause considerable carbon fiber oxidation. Criteria estimates were determined for the number of micron carbon fibers released during an aircraft accident. An extreme case analysis indicated that the upper limit of the micron carbon fiber concentration level was only about half the permissible asbestos ceiling concentration level.

Sussholz, B.↗

Ultrasonic nondestructive evaluation of impact-damaged graphite fiber composite

Unidirectional Hercules AS/3501-6 graphite fiber epoxy composites were subjected to repeated controlled low-velocity drop weight impacts in the laminate direction. The degradation was ultrasonically monitored using through-thickness attenuation and a modified stress wave factor (SWF). There appears to be strong correlations between the number of drop-weight impacts, the residual tensile strength, the through-thickness attenuation, and the SWF. The results are very encouraging with respect to the NDE potential of both of these ultrasonic parameters to provide strength characterizations in virgin as well as impact-damaged fiber composite structures.

Williams, J. H., Jr.↗

Thermal cycling graphite-polyimide

The effects of repetitive thermal cycling on the temperature-thermal deformation relation of graphite-polyimide were determined. The bending and axial strains, measured with strain gages, of unsymmetric 0 deg sub 2/90 deg sub 2 and 0 deg sub 4/90 deg sub 4 laminates were used as an indication of thermal deformation. The strains were measured as a function of temperature and two temperature ranges were used, room temperature to 180 C and room temperature to 315 C. Five cycles were run in each temperature range and the cycling was done in quasistatic fashion. The response of a flat 0 deg sub 8 laminate was measured as were the effects of repetitive cycling on the strain gages themselves. A piece-wise linear theory, based on classical lamination theory and using the variation of mechanical and thermal expansion properties with temperature, was compared with the experimental results. The correlation between theoretical predictions and experimental results for the thinner laminate was poor.

Hyer, M. W.↗

The structural behavior of a graphite-polymide honeycomb sandwich panel with quasi-isotropic face sheets and an orthotropic core

The results of a series of tests of graphite-polyimide honeycomb sandwich panels are presented. The panels were 1.22 m long, 0.508 m wide, and approximately 13.3 m thick. The face sheets were a T-300/PMR-15 fabric in a quasi-isotropic layup and were 0.279 mm thick. The core was Hexcel HRH 327-3/16 - 4.0 glass reinforced polyimide honeycomb, 12.7 mm thick. Three panels were used in the test: one was cut into smaller pieces for testing as beam, compression, and shear specimens; a second panel was used for plate bending tests; the third panel was used for in-plane stability tests. Presented are the experimental results of four point bending tests, short block compression tests, core transverse shear modulus, three point bending tests, vibration tests, plate bending tests, and panel stability tests. The results of the first three tests are used to predict the results of some of the other tests. The predictions and experimental results are compared, and the agreement is quite good.

Hyer, M. W.↗

Development of a fire test facility for graphite fiber-reinforced composites

A number of modifications were added to the Model 25 facility to make it specifically applicable for composite material screening tests. Most significant was the development of hardware for trapping fibers released during test and isolating them for quantitative measurement. Capability was added for increasing test section velocities and increasing the range of air/fuel ratios available from very rich to very lean. A provision was added for agitation of the test specimen and the combustion gases by a pulsating gas supply. A variety of specimen configurations was evaluated by an extensive series of tests on a graphite-epoxy reference composite which is representative of material currently used in advanced aircraft. A standard test technique and specimen configuration were established which was satisfactory for the reference composite. A test program was then performed on several alternate composite materials to verify the validity of the test method for relative evaluation of a variety of composite materials.

Alexander, J. G.↗

Transverse microcracking in Celion 6000/PMR-15 graphite-polyimide

The effects of room temperature tensile loading and five thermal loadings, in the range -320 F (-196C) to 625F (330CC), upon the development of transverse microcracks (TVM) in Celion 6000/PMR-15 graphite-polyimide laminates were investigated. Microcracks were observed using a replicating technique, microscopy and X-ray. The mechanical or thermal load at which microcracking initiates and the ply residual stresses were predicted using laminate analysis with stress- and temperature-dependent material properties.

Mills, J. S.↗

The spectral opacity of triatomic carbon measured in a graphite tube furnace over the 280 to 600 nm wavelength range

The opacity of linear triatomic carbon (C3) was measured in a graphite tube furnace from 280 to 600 nm to supplement the earlier measurements of Brewer and Engelke. The spectral cross section was estimated from the opacities using temperature profiles determined pyrometrically and a revised heat of formation delta H = 198 kcal/mole). The cross section was found to be nonnegligible over the range 300 to 500 nm and the electronic oscillator strength based on the total cross section estimate was 0.02.

Snow, W. L.↗

The effects of thermal cycling on the thermal deformation of graphite-polyimide

The effects of repetitive thermal cycling on the thermal deformation of graphite-fiber-reinforced polyimide laminates are investigated. Unsymmetric and unidirectional laminate specimens were cycled in an oven between room temperature and 180 or 315 C five times, and temperature and deformation were recorded as a function of time in order to measure thermal deformation. The results of the lower temperature cycling reveal a hysteresis-like effect in the temperature-thermal deformation relation for a single cycle, while no differences are detected from one cycle to the next. The response of an eight-layer curved specimen is found to agree well with predictions based on a piecewise-linear lamination theory, however, four-layer laminate response could not be explained. The results of the high-temperature tests also indicate a dependence of the strain on whether the specimen was being heated or cooled, however quantitative results are considered unreliable, due to strain gage difficulties.

Hyer, M. W.↗

Effects of moisture on apparent flexure strength and on torsion and flexure fatigue properties of graphite-epoxy composites

The effects of moisture and temperature on unidirectional and multi-ply laminates of T300/934 and AS/3501 graphite-epoxy systems were investigated. Properties studied were static flexure strength and flexure and torsion fatigue strengths at room temperature and at 74 C. Specimens with increased moisture content showed a reduced static flexure strength; water as the test environment had only a negligible influence. In flexure fatigue and torsion fatigue, the water environment caused somewhat reduced fatigue strengths at room temperature and significantly greater degradation in 74 C water. The failure mode in all cases was interlaminar delamination.

Sumsion, H. T.↗

Two-dimensional O2 adsorbed on graphite

Properties of two-dimensional O2 adsorbed on graphite are calculated in the extremely low-coverage delta region and for monolayers, with use of pattern-recognition optimization and Monte Carlo techniques. Equilibrium configurations and orientations, orientational order-disorder, melting, and dissociation transitions are predicted at various O2 densities. Phase characteristics, including a plastic crystallite phase, are compared with experiment.

Etters, R. D.↗

The spectral opacity of triatomic carbon measured in a graphite tube furnace over the 280 to 600 nm wavelength range

The paper presents the measurements of linear triatomic carbon opacity (C3) made in a graphite tube furnace to extend the wavelength range of Brewer and Engelke (1962) to the 280-600 nm range. An electrooptical method was used to determine C3 absorption in argon at 2720 to 3060 K; a quartic polynomial regression expression was derived to provide a complete temperature profile from pyrometer measurements. The C3 spectra were plotted for several opacity levels. It was concluded that the extension of the spectral range to the near u.v. levels made it easier to identify C3 particles.

Snow, W. L.↗

Graphite-epoxy panel compression strength reduction due to local impact

The effects of low velocity impact on the compressive strength of graphite/epoxy structures are reviewed. Extensive tests were conducted on sandwich beams, laminated plates and stiffened panels. Conditions for failures were investigated by impact tests on statically loaded test specimens. Lightly loaded graphite structures (such as aircraft secondary structure) were insensitive to impact damage. In more heavily loaded structures, (such as wing panels), appreciable reductions in compressive strength occurred. The implications of the tests for structural design are discussed by comparing panel masses for designs where ultimate strains were reduced due to impact considerations with the masses of designs with higher ultimate strains. Preliminary test data are presented to show the possibility of improvements in damage to tolerance achievable by using an alternate matrix material.

Card, M. F.↗

Graphite fiber surface treatment to improve char retention and increase fiber clumping

Composites containing carbon and graphite fibers can release fibers into the atmosphere during a fire. This release can potentially cause failure in some types of electrical equipment. Reduced fiber dispersion during and after combustion will reduce risks. Epoxidized char forming systems were synthesized which will react with commercially available surface treated carbon fiber. Fibers modified with these char formers retained adhesion in a specific epoxy matrix resin. Small scale combustion testing indicates that using these char former modified fibers in laminates will help to reduce the dispersement of fibers resulting from exposure to fire without sacrificing resin to fiber adhesion.

Paul, J. T., Jr.↗