Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “flow testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

Performance Evaluation of a Respirator Vortex Cooling Device

The United States Department of Energy's Savannah River Site (SRS) in Aiken, South Carolina, is dedicated to promoting site-level, risk-based inspection practices to maintain a safe and productive work environment. Protective suits are worn by personnel working in contaminated environments. These suits require that cooling be applied to keep the interior temperature within safe and comfortable limits. A vortex tube, also known as the Ranque-Hilsch vortex tube (RHVT), can provide the necessary cooling. As mechanical devices void of moving components, vortex tubes separate a compressed gas into hot and cold streams—the air emerging from the “hot” end reaching a temperature of 433.2 K and the air emerging from the “cold” end reaching a temperature of 241.5 K (Hilsch, 1946, “Die Expansion Von Gasen Im Zentrifugalfeld Als Kälteprozeß,” Z. Für Naturforsch., 1, pp. 208–214). Routing the cold stream of the vortex tube to the user's protective suit facilitates the required cooling. Vortex tubes currently in use at SRS are preset, through modification solely by and within the SRS respiratory equipment facility (REF), to provide a temperature reduction between 22.2 and 25.0 K. When a new model of vortex tube capable of user adjustment during operation recently became available, prototype testing was conducted for product comparison. Ultimately, it was identified that similar cooling performance between the old and new models is achievable. Production units were acquired to be subjected to complete product analysis at SRS utilizing a statistical test plan. Finally, the statistical test plan, data, thermodynamic calculations, and conclusions were reviewed to determine acceptability for site use.

47 OTHER INSTRUMENTATION↗

Optimization-Inspired Pin-Fin Array for Supercritical Carbon Dioxide Recuperator

Additively manufactured heat exchangers are one possible route to cost-effective sCO 2 power cycles. In this paper, experimental results are obtained for two helical pin fin tubes that were designed following parametric optimization of the fin array. Neither the numerical optimization nor the experimental testing have been previously reported in the literature. The two tube designs were, (1) the optimization inspired design, and (2) the optimization-inspired design with a fin diameter increased by a factor of 2. To characterize the print, the designs were scanned using X-ray computed tomography to measure feature sizes and heat transfer area. The optimization was conducted in a commercial, computational fluid dynamics code. The code solved the Reynolds Averaged Navier-Stokes (RANS) and energy equations with turbulence closure provided by the shear stress transport (SST) k-ω model. In the experiments, the Nusselt number augmentation was measured using the Wilson plot technique and the friction factor was determined with mass flow and pressure drop measurements. The experimental testing indicated that the optimization-inspired design had a friction factor that was four times less than the baseline tube design at equal Nusselt number. Additionally, the optimization-inspired design had a 14% improvement in Nusselt number, at equal friction factor, relative to the best performing computational fluid dynamics (CFD) trial points. Tube design (2), with the larger diameter pin fins, had similar performance, within experimental error, as the tube with the smaller diameter pin fins (1). Both tubes achieved overall fin array efficiencies near 1. A performance factor, V/V 0 , equal to the volume of the enhanced heat exchanger divided by the volume of the baseline (no-fins) heat exchanger, is recommended to quantify internal cooling performance. In conclusion, the experimental shell and tube heat exchanger, using the additively manufactured tube, is competitive with printed circuit heat exchangers in its pressure drop class and could be further improved by optimizing a shell-and-tube heat exchanger utilizing this heat transfer enhancement feature.

42 ENGINEERING↗

ON-LINE MONITORING OF I&C TRANSMITTERS AND SENSORS FOR CALIBRATION VERIFICATION AND RESPONSE TIME TESTING WAS SUCCESSFULLY IMPLEMENTED AT ATR

The Advanced Test Reactor (ATR) has always had a comprehensive procedure to verify the performance of its critical transmitters and sensors, including RTDs, and pressure, level, and flow transmitters. These transmitters and sensors have been periodically tested for response time and calibration verification to ensure accuracy. With implementation of online monitoring techniques at ATR, the calibration verification and response time testing of these transmitters and sensors are verified remotely, automatically, hands off, include more portions of the system, and can be performed at almost any time during process operations. The work was done under a DOE funded SBIR project carried out by AMS. As a result, ATR is now able to save the manpower that has been spent over the years on manual calibration verification and response time testing of its temperature and pressure sensors and refocus those resources towards more equipment reliability needs. More importantly, implementation of OLM will help enhance the overall availability, safety, and efficiency. Together with equipment reliability programs of ATR, the integration of OLM will also help with I&C aging management goals of the Department of Energy and long-time operation of ATR.

47 OTHER INSTRUMENTATION↗

On-line monitoring of I and C transmitters and sensors for calibration verification and response time testing was successfully implemented at ATR - 326

The Advanced Test Reactor (ATR) has always had a comprehensive procedure to verify the performance of its critical transmitters and sensors, including RTDs, and pressure, level, and flow transmitters. These transmitters and sensors have been periodically tested for response time and calibration verification to ensure accuracy. With implementation of on-line monitoring techniques at ATR, the calibration verification and response time testing of these transmitters and sensors are verified remotely, automatically, hands off, include more portions of the system, and can be performed at almost any time during process operations. The work was done under a DOE funded SBIR project carried out by AMS. As a result, ATR is now able to save the manpower that has been spent over the years on manual calibration verification and response time testing of its temperature and pressure sensors and refocus those resources towards more equipment reliability needs. More importantly, implementation of OLM will help enhance the overall availability, safety, and efficiency. Together with equipment reliability programs of ATR, the integration of OLM will also help with I and C aging management goals of the Department of Energy and long-time operation of ATR. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Effect of stress states on the deformation behavior of Cu-based bulk metallic glass in the supercooled liquid region

The effect of stress states on the deformation behavior of the Cu54Zr22Ti18Ni6 bulk metallic glass (BMG) alloy was studied in the supercooled liquid region. At 723 K, Newtonian plastic flow governed the deformation during the compression test, whereas strain-hardening occurred during the tensile test. At 733 K, a fast failure was observed during tensile test. The diffusion rate of Cu atoms in the BMG alloy plays an important role in the deformation behavior. The fast diffusion of Cu atoms under the tensile stress state caused faster crystallization leading to a fast strain-hardening during the tensile plastic deformation. Published by Elsevier B.V.

36 MATERIALS SCIENCE↗

Measurement-based Coherency Identification and Aggregation for Power Systems

In power system model reduction, a high reduction ratio is often desired to handle much more complex power systems. The bottleneck of traditional methods lies in: Coherency identification methods are conservative. Some coherency generators are not detected when system topology or operating points change, because coherency identification depends on system topology or operating points. There are some solitary generators in external systems. These generators do not belong to any coherency group. However, sometimes these solitary generators have little impact on tie-line power flow, and it might be possible to ignore their dynamics in model reduction. But because they do not belong to any coherency group, existing reduction methods cannot handle them well. In order to overcome the first problem, a measurement-based online coherency identification method is presented in this paper. By analyzing post-fault trajectories measured by Phasor Measurement Units (PMUs), coherency generators are identified through principal component analysis. The method can track time-varying system topology and operating points. In order to address the second problem, this paper introduces sensitivity analysis into traditional reduction methods. The sensitivity of tie-line power flow against injected active power of external system generators is derived. Those generators having loose connection with tie-line power are identified through the sensitivity analysis, and their dynamics are ignored by replacing them with negative impedances. We test if the sensitivity, based on static power flow, provides good guidance to reduce the dynamic model. Case studies show that the proposed method can handle well these solitary generators and the reduction ratio can be enhanced through this method. Future work will include generalization of the sensitivity method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

AN EXPERIMENT TO STUDY PEBBLE BED LIQUID-FLUORIDE-SALT HEAT TRANSFER

A forced-convection liquid-fluoride-salt loop is being constructed at Oak Ridge National Laboratory (ORNL). This loop was designed as a versatile experimental facility capable of supporting general thermal/fluid/corrosion testing of liquid fluoride salts. The initial test configuration is designed to support the Pebble Bed Advanced High-Temperature Reactor and incorporates a test section designed to examine the heat transfer behavior of FLiNaK salt in a heated pebble bed. The loop is constructed of Inconel 600 and is capable of operating at up to 700oC. It contains a total of 72 kg of FLiNaK salt and uses an overhung impeller centrifugal sump pump that can provide FLiNaK flow at 4.5 kg/s with a head of 0.125 MPa. The test section is made of silicon carbide (SiC) and contains approximately 600 graphite spheres, 3 cm in diameter. The pebble bed is heated using a unique inductive technique. A forced induction air cooler removes the heat added to the pebble bed. The salt level within the loop is maintained by controlling an argon cover gas pressure. Salt purification is performed in batch mode by transferring the salt from the loop into a specially made nickel crucible system designed to remove oxygen, moisture and other salt impurities. Materials selection for the loop and test section material was informed by 3 months of Inconel 600 and SiC corrosion testing as well as tests examining subcomponent performance in the salt. Several SiC-to-Inconel 600 mechanical joint designs were considered before final salt and gas seals were chosen. Structural calculations of the SiC test section were performed to arrive at a satisfactory test section configuration. Several pump vendors provided potential loop pump designs; however, because of cost, the pump was designed and fabricated in-house. The pump includes a commercial rotating dry gas shaft seal to maintain loop cover gas inventory. The primary instrumentation on the loop includes temperature, pressure, and loop flow rate measurement. Although techniques for all these measurements have improved, no commercial instrumentation was available for flow and pressure measurement that had been tested under these conditions. Instrumentation was tested and modified to meet both corrosion and temperature requirements. This paper discusses the issues encountered during the design and construction of the ORNL Liquid Salt Loop and should prove useful to those contemplating construction of similar high-temperature liquid-fluoride-salt facilities.

36 MATERIALS SCIENCE↗

Numerical investigation of multiphase flow through self-affine rough fractures

Multiphase flow through fractures has great significance in subsurface energy recovery and gas storage applications. Different fracture and flow properties affect flow through a fracture which is difficult to control in laboratory experiments. Here, we perform lattice Boltzmann simulations in an ensemble of synthetically generated fractures. Drainage simulations are performed at different capillary numbers, wettability, and viscosity ratios. We track the invading front and quantify breakthrough saturations and show that roughness and wettability have a strong effect on fluid invasion through a complex fracture. Invading a more viscous fluid results in more stable displacement regardless of the capillary number while at very low capillary numbers, fluid migration is dependent on the inherent structure of the fracture. We develop a fluid displacement phase diagram in a single rough fracture and compare our results from that in the literature. Finally, we extend the phase diagrams across multiple fractures and demonstrate the importance of natural fracture features of roughness and wettability in identifying stable versus unstable displacement regimes during multiphase flow through rough fractures. Our work presents an end-to-end numerical pathway for testing on experimental data and expanding numerical data sets for testing combinations of different physical phenomenon and make valuable predictions on fluid flow through rough fractures.

02 PETROLEUM↗

Hypersonic wake velocity measurements using acetone molecular tagging velocimetry

Molecular tagging velocimetry, a minimally intrusive laser diagnostic, was used to find quantitative off-body velocity measurements in the wake of both strut-mounted and free-flight spheres in hypersonic flow. Acetone gas seeded in the flow was excited using the fourth harmonic of a pulse-burst Nd:YAG laser. The experimental tests were validated and compared to simulations using a continuous Galerkin flow solver and an adaptive mesh refinement process. Near the centerline in the wake of the sphere, velocities between −105 and 65 m/s were observed due to reverse flow in the viscous shear layer. Similarly, the simulated data showed negative velocity values in the shear layer region. Outside of the shear layer, average velocities of 730 m/s were observed in both the experimental and simulated results. The overall average uncertainty for the strut-mounted and free-flight cases was estimated to have an accuracy of ±4% (±35.5m/s or 4.9%). In conclusion, this non-intrusive technique provides a velocity map of the wake behind a sphere under hypersonic conditions.

42 ENGINEERING↗

Tidal Turbine Test, Downeast Turbines, July 12, 2021

Downeast Turbines tested a tidal turbine prototype with novel rotor/channel system and lateral effluent discharge apparatus (LEDA), during five days of testing in the flume at Alden Lab. Three days of testing (July 12-14, 2021) focused on turbine power metrics of torque and rpm, which were low, and then two days of follow-up testing (July 27-28, 2021) focused on LEDA performance metrics of pressure differential and rates of volumetric flow, with encouraging results. Next step is to to characterize, and even optimize, configurations of the LEDA, using 3D-CFD as a helpful tool, to refine its shape and explore its limits of performance as a means of effluent discharge that augments performance of an instream turbine. An improved configuration of the LEDA will be re-combined with the rotor/channel system of the turbine prototype, and ultimately, the rotor will be re-sized (enlarged), to better match the LEDA's performance capabilities in drawing through a rate of volumetric flow. This submission is Downeast Turbines' Post Access Report for the test event. It includes the files described here (next below), and several reference links. "Downeast TEAMER-Post-Access-Report...docx" is a document file containing the report. "Appendices A, B, and C" are included in this file, and so are "Figures #1-7." "Appendix D - Test Data Workbooks.zip" is an archive file containing all post access data (raw data tables, calculating tables, and graphs), presented in fourteen Excel workbooks as described in the report. "Appendix E - Post Access Figures.zip" is an archive file containing "Figures #8-52," of the report.

16 TIDAL AND WAVE POWER↗

Building America Case Study: Sealed Crawl Spaces with Integrated Whole-House Ventilation in a Cold Climate, Ithaca, New York

"9One method of code-compliance for crawlspaces is to seal and insulate the crawlspace, rather than venting to the outdoors. However, codes require mechanical ventilation; either via conditioned supply air from the HVAC system, or a continuous exhaust ventilation strategy. As the CARB's building partner, Ithaca Neighborhood Housing Services, intended to use the unvented crawlspace in a recent development, CARB was interested in investigating a hybrid ventilation method that includes the exhaust air from the crawlspace as a portion of an ASHRAE 62.2 compliant whole-house ventilation strategy. This hybrid ventilation method was evaluated through a series of long-term monitoring tests that observed temperature, humidity, and pressure conditions through the home and crawlspace. Additionally, CARB worked with NREL to perform multi-point tracer gas testing on six separate ventilation strategies - varying portions of 62.2 required flow supplied by the crawlspace fan and an upstairs bathroom fan. The intent of the tracer gas testing was to identify effective Reciprocal Age of Air (RAoA), which is equivalent to the air change rate in well-mixed zones, for each strategy while characterizing localized infiltration rates in several areas of the home.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Effect of compressibility on strong shock and turbulence interactions

The interactions between turbulent flows and shock waves are important in many natural processes as well as scientific and engineering applications. One of the fundamental building blocks in these complex processes and applications is the canonical problem of isotropic turbulence and a normal shock. Unfortunately, even this fundamental problem is not well understood. Recent direct numerical simulation (DNS) results of perfect gas flow showed some new trends in turbulent statistics as mean Mach number is increased. In this paper, we first conduct extensive DNS studies on canonical strong shock and turbulence interaction problem of perfect gas flow with mean Mach numbers ranging from 2 to 30, with the emphasis on investigating the effect of compressibility. The results show that maximum values of variance of streamwise vorticity fluctuations first increase and then decrease as shock strength is increased. The peak of streamwise vorticity fluctuations is observed for shock and turbulence interactions with Mach 2.8 shock. For stronger than Mach 2.8 shocks, there is a decrease in streamwise vorticity fluctuations. The amplification of Reynolds stress R11 decreases as mean Mach number is increased till 8.8, which is consistent with findings of linear interaction analysis. This trend, however, reverses as shock strength is increased beyond Mach 8.8. For stronger than Mach 8.8 shocks, Reynolds stress R11 is amplified as mean Mach number keeps increasing. Since gas temperature increases dramatically after strong shocks, we are also working on DNS of nonequilibrium flow, where non-equilibrium flow effects including internal energy excitations, translation-vibration energy relaxation, and chemical reactions among different species are considered based on the 5-species air chemistry and recently thermal property models. The code and corresponding thermo-chemical models have been tested on two cases of non-equilibrium flow over cylinders.

Wang, Xiaowen↗

Validation of the integration of CFD and SAS4A/SASSYS-1: Analysis of EBR-II shutdown heat removal test 17

Recent analyses have demonstrated the need to model multidimensional phenomena, particularly thermal stratification in outlet plena, during safety analyses of loss-of-flow transients of certain liquid-metal cooled reactor designs. Therefore, Argonne's reactor systems safety code SAS4A/SASSYS-1 is being enhanced by integrating 3D computational fluid dynamics models of the plena. A validation exercise of the new tool is being performed by analyzing the protected loss-of-flow event demonstrated by the EBR-II Shutdown Heat Removal Test 17. In this analysis, the behavior of the coolant in the cold pool is modeled using the CFD code STAR-CCM+, while the remainder of the cooling system and the reactor core are modeled with SAS4A/SASSYS-1. This paper summarizes the code integration strategy and provides the predicted 3D temperature and velocity distributions inside the cold pool during SHRT-17. The results of the coupled analysis should be considered preliminary at this stage, as the exercise pointed to the need to improve the CFD model of the cold pool tank. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Comparison of depth-averaged concentration and bed load flux sediment transport models of dam-break flow

This paper presents numerical simulations of dam-break flow over a movable bed. Two different mathematical models were compared: a fully coupled formulation of shallow water equations with erosion and deposition terms (a depth-averaged concentration flux model), and shallow water equations with a fully coupled Exner equation (a bed load flux model). Both models were discretized using the cell-centered finite volume method, and a second-order Godunov-type scheme was used to solve the equations. The numerical flux was calculated using a Harten, Lax, and van Leer approximate Riemann solver with the contact wave restored (HLLC). A novel slope source term treatment that considers the density change was introduced to the depth-averaged concentration flux model to obtain higher-order accuracy. A source term that accounts for the sediment flux was added to the bed load flux model to reflect the influence of sediment movement on the momentum of the water. In a one-dimensional test case, a sensitivity study on different model parameters was carried out. For the depth-averaged concentration flux model, Manning's coefficient and sediment porosity values showed an almost linear relationship with the bottom change, and for the bed load flux model, the sediment porosity was identified as the most sensitive parameter. The capabilities and limitations of both model concepts are demonstrated in a benchmark experimental test case dealing with dam-break flow over variable bed topography.

58 GEOSCIENCES↗

Recalibrating Best Practices, Challenges, and Limitations of Estimating Tree Transpiration Via Sap Flow

Purpose: Transpiration dominates hydrologic fluxes from terrestrial ecosystems to the atmosphere. Sap flow is the most widely used method to quantify transpiration, and calibrations can improve the accuracy of these estimates. Despite numerous suggestions to perform and apply sap flow calibrations, seemingly few reports apply these recommendations. Here, we sought to determine the prevalence of calibration across sap flow methodology. Recent Findings: In this work, we reviewed tree sap flow literature over the past nine years and determined that only 5.3% of these publications documented the performance of calibrations, the application of coefficients from previous calibrations, or the application of correction factors using calibration data to ensure or improve accuracy of transpiration estimates. These data indicate that calibration has not been adopted as a best practice. However, these data may also reflect challenges to the performance and application of calibration indicating fundamental limitations of sap flow methods. Summary: We highlight the need for testing critical assumptions regarding calibration; specifically, that coefficients derived from calibrations on small stems are suitable for application to large stems and that different calibration approaches yield similar transpiration estimates. We encourage researchers to adopt calibration as a best practice for sap flow data and to explain how calibration was performed, how calibration data were applied, and to acknowledge and justify circumstances that preclude or do not necessitate calibration. Without the adoption of calibration and an improved understanding of its limitations, our understanding of transpiration and ability to quantify it using this technology will remain inadequate.

54 ENVIRONMENTAL SCIENCES↗

A channel flow cell with double disk electrodes for oxygen electroreduction study at elevated temperatures and pressures: Theory

We report a new double-disk-electrode channel flow cell has been designed, constructed and tested. A theoretical treatment and implicit finite difference numerical simulations are presented, which permit the computation of the hydrodynamic behavior of this cell under steady state conditions, i.e., the diffusion limited current at the working electrode and the collection efficiency of the detector. The simulated results are consistent with those measured experimentally, indicating that our simulations appropriately describe the hydrodynamic behavior of this cell. The oxygen reduction reaction (ORR) on a carbon-supported nanoparticle Pt catalyst at both room temperature and 110 °C were preliminarily studied with this cell.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluation of high strength, high conductivity CuNiBe alloys for fusion energy applications

The unirradiated tensile properties for several different heats and thermomechanical treatment conditions of precipitation strengthened Hycon 3HPTM CuNiBe (Cu-2%Ni-0.35%Be in wt.%) have been measured over the temperature range of 20-500 C for longitudinal and long transverse orientations. The room temperature electrical conductivity has also been measured for several heats, and the precipitate microstructure was characterized using transmission electron microscopy. The CuNiBe alloys exhibit very good combination of strength and conductivity at room temperature, with yield strengths of 630-725 MPa and electrical conductivities of 65-72% International Annealed Copper Standard (IACS). The strength remained relatively high at all test temperatures, with yield strengths of 420-520 MPa at 500 C. However, low levels of ductility (<5% uniform elongation) were observed at test temperatures above 200-250 C, due to flow localization near grain boundaries (exacerbated by having only 10-20 grains across the gage thickness of the miniaturized sheet tensile specimens). Scanning electron microscopy observation of the fracture surfaces found a transition from ductile transgranular to ductile intergranular fracture with increasing test temperature. Fission neutron irradiation to a dose of ~0.7 displacements per atom (dpa) at temperatures between 100 and 240 C produced a slight increase in strength and a significant decrease in ductility. The measured tensile elongation increased with increasing irradiation temperature, with a uniform elongation of ~3.3% observed at 240 C. The electrical conductivity decreased slightly following irradiation, due to the presence of defect clusters and Ni, Zn, Co transmutation products. Considering also previously published fracture toughness data, this indicates that CuNiBe alloys have irradiated tensile and electrical properties comparable or superior to CuCrZr and oxide dispersion strengthened copper at temperatures <250 C, and may be an attractive candidate for certain fusion energy structural applications. Conversely, CuNiBe may not be preferred at intermediate temperatures of 250-500 C due to the poor ductility and fracture toughness of CuNiBe alloys at temperatures >250 C. The potential deformation mechanisms responsible for the transition from transgranular to intergranular fracture are discussed. The possible implications for other precipitation hardened alloys such as nickel based superalloys are briefly discussed.

Zinkle, Steven J↗

Thermal Testing Quality Assurance of 24LCC & 3LCC Electronic Packages

The purpose of this project is to experimentally validate the thermal fatigue life of solder interconnects for a variety of surface mount electronic packages. Over the years, there has been a significant amount of research and analysis in the fracture of solder joints on printed circuit boards. Solder is important in the mechanical and electronic functionality of the component. It is important throughout the life of the product that the solder remains crack and fracture free. The specific type of solder used in this experiment is a 63Sn37Pb eutectic alloy. Each package was manufactured with conformal coating along with and without an underfill material below the device. Conformal coating helps protect the board from environments such as electrostatic discharge and humidity. It is commonly used in broad types of engineering disciplines such as commercial, military, research and development, etc. Conformal coating can also pose a risk for the life of the board because of its high thermal expansion coefficient. This can greatly decrease the life of the product if it regularly sees high temperature variations. This leads to a shorter fatigue life of the solder. The fatigue life is a common mechanical problem in the field of electronic devices. Adding underfill can help increase the fatigue life of the solder. However, applying underfill adds time to manufacturing and production. This ultimately increases the cost per unit. The study of conformal coated printed circuit boards with and without underfill was done on two different surface mount electronic packages. The electronic packages studied were 24 and 3 contact Leadless Ceramic Chips packages. When the package was not underfilled, the coating was allowed to flow underneath. The assembly was analyzed and tested to obtain the best available combination of conformal coating, underfill, and potting to design the most robust and reliable circuit board while keeping in mind certain factors such as cost, manufacturing time, and need. Different types of conformal coatings were considered with and without underfill for each device. 29 of each component were manufactured to have a large sample size and for the sake of individual defects and imperfections. Finite Element Analysis (FEA) was performed by an engineer at Sandia National Laboratories for both Leadless Ceramic Chips. From the FEA results, a test acceleration profile was derived and the number of temperature cycles to fail the solder interconnects were found for three different cases. Experimentation was done as a secondary measure to validate this data to show confidence in the theoretical analysis. Accelerated testing functions as a quality check for the product. Accelerated testing is extremely useful in the research and development phase of engineering. It can save money from the potential of early life defects and the costs that come along with warranties. Accelerated testing makes a weaker design more robust and checks the reliability of a strong design in a shorter period of time. It is extremely helpful in a world where deliverables are in high demand and scheduling is tight. Accelerated testing helps the engineer gain an understanding of what needs to be improved and what works well. There are many different types of accelerated tests. Our circuit boards were accelerated inside a closed thermal chamber because of the high number of use cycles. The ultimate goal of this experimentation is to help identify what will prevent any premature cracking or fracturing in the solder alloy. It is important to understand that underfilling each component may or may not be needed. If underfill is not needed, there are several production benefits.

42 ENGINEERING↗