Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “fast reactors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,427 records · Page 80

Performance of neutron and proton irradiated AC-LGAD sensors

Characterization of strip and pixel AC-LGAD devices with both laser TCT and probe station (IV/CV) will be shown on AC-LGADs irradiated with 1 MeV reactor neutrons at JSI/Ljubljana and with 400 MeV protons at FNAL ITA to fluences from 1e13~$n_{eq}/cm^2$ to a few times 1e15~$n_{eq}/cm^2$. This study was conducted within the scope of the ePIC detector time of flight (TOF) layer R&D program at the EIC, which will feature AC-LGADs with strip and pixel geometry. Sensors in the TOF layer will receive up to 1e13 $n_{eq}/cm^2$ fluence over the lifetime of the experiment.

AC-LGAD strips↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗

ENDF/B-VIII.1: Neutron Reaction Sublibrary

The neutrons sublibrary aims to describe nuclear reactions between incident neutron particles and different nuclei. For ENDF/B-VIII.1, many neutron files were re-evaluated or received major changes. A new 239Pu evaluation was jointly-produced by IAEA, LANL, LLNL and ORNL bringing important updates to fission neutron multiplicity, Prompt Fission Neutron Spectrum, resonance and fast regions. Around one third of the new neutron evaluations were performed as part of the INDEN collaboration, including 16,18 O, 19 F, 28,29,30 Si, 63,65 Cu, 50,51,52,53,54 Cr, 55 Mn, 54,56,57 Fe, 139 La, 233,235,238 U, 240,241 Pu. Important non-INDEN evaluations include 234,236 U, 206,207,208 Pb, 181 Ta, 88 Sr, 140,142 Ce, Pt and Dy isotopes, and many others. Also, dosimetry reactions from IRDFF-II were adopted for many materials.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Boron‐Doped Nano‐Crystalline Coated Carbon Fibers for Phasic Dopamine Sensing

Real time, chronic electrochemical detection of neurotransmitters will provide a positive step in the treatment and understanding of neurological disease. However, current electrodes using carbon fibers (CF) fail to perform chronically. While diamond-based coatings show promise in improving their longevity, achieving a uniform layer of such coatings on CFs is challenging, and the electrodes often lose sensitivity after coating. In this work, a complete and uniform boron-doped nanocrystalline material grown in a diamond reactor (B-NCD) was developed to coat CF microelectrodes for neurochemical sensing. The coating was characterized electrically, optically, mechanically, and chemically. The B-NCD coated CF electrodes were able to detect phasic dopamine at a sensitivity comparable to the most widely used alternatives (uncoated and PEDOT:Nafion coated CFs). During biofouling testing, the B-NCD coated CF electrodes demonstrated better stability than uncoated CFs and comparable performance to PEDOT:Nafion coated CFs. Moreover, B-NCD exhibited no signs of degradation during consecutive FSCV applications, while uncoated and PEDOT:Nafion coated CF electrodes degraded significantly over time. Furthermore, the B-NCD coating supported the survival and development of neurons and astrocytes in vitro, exhibited excellent adhesion and durability during mechanical bending testing, and enabled successful in vivo recording of phasic dopamine release in the rat brain. Overall, B-NCD coated CFs present as an ideal candidate for chronic, flexible neural implantable electrodes for long-term neurochemical monitoring.

carbon fiber↗

AGR-3/4 TRISO Fuel Compact Ceramography

The combined third and fourth irradiation in the Advanced Gas Reactor (AGR) program (AGR-3/4) contained tristructural isotropic (TRISO)-coated particle fuel and designed-to-fail (DTF) fuel particles. The DTF particles were only coated with highly anisotropic pyrocarbon (PyC) so they would purposely fail during the AGR-3/4 irradiation and provide a source of fission products for measurement. To observe the post-irradiation morphology of these DTF particles and the TRISO-coated particles, three AGR-3/4 compacts were mounted in epoxy, sectioned above their centerlines, and ground/polished. Three rounds of grinding/polishing and optical microscopy were performed so that the particles could be observed at multiple planes. Each compact contained approximately 1,872 TRISO particles and exactly 20 DTF particles. The three AGR-3/4 compacts examined covered a wide temperature range and featured both the hottest average irradiation temperature (1375°C) and the coldest/lowest burnup (872°C and 5.5% fissions per initial metal atom) of any compacts to undergo post-irradiation examination (PIE) in the AGR program to date. A total of 29 DTF particles were located and observed via microscopy across the three compacts. All the DTF particles observed via microscopy had completely failed PyC coatings. Some different DTF kernel and PyC morphologies were observed that have been attributed to the differences in irradiation temperature and/or burnup. At low and medium irradiation temperatures (roughly 850 to 1050°C), it appears irradiation-induced dimensional changes in the DTF PyC caused it to fracture and fold in on itself, and the kernel deformed to accommodate this PyC deformation. The extent of DTF kernel deformation to accommodate DTF PyC buckling tended to be greater for the medium-temperature fuel compared to the cold fuel. In the high-irradiation-temperature compact (1375°C), the DTF PyC layer appears to have completely reacted chemically with the kernel material. The only material surrounding the DTF particles in this hot compact resembles the compact matrix material. Observations of the TRISO-coated driver fuel particles and fuel compact graphitic matrix were also made. The TRISO particle kernels in the medium-temperature compact (1047°C), and many in the high-temperature compact (1375°C), showed morphologies consistent with what was seen in AGR-1 and AGR-2. In other TRISO particles from the high-temperature compact, a spatial gradient in the kernel appearance was evident. Here the cool side of the kernel (away from the center of the compact) had a much darker appearance (like that of the buffer and pyrocarbon). This is the first observation of this kind of kernel spatial gradient in AGR fuel. It is believed that the high irradiation temperature of that compact (an average of 1375°C) activates or accelerates an unidentified chemical reaction, and the temperature gradient within the fuel causes a sharp spatial gradient. The low-temperature/low-burnup compact also showed unique kernel morphologies where the TRISO-coated particles had clearly distinguishable oxide and carbide phases at the center of the kernel, an oxide rind surrounding this, and remnants of a carbide skin surrounding the oxide rind. These are features observed in the as-fabricated fuel that are no longer present in higher burnup fuel. Occasional gaps between the outer pyrolytic carbon (OPyC) and graphitic matrix material were observed in all compacts. Gaps were most often found in the small, matrix-filled spaces between adjacent particles. Finally, buffer morphologies in AGR-3/4 TRISO particles were like those observed in AGR-1 and AGR-2, and the buffer fracture frequencies in AGR-3/4 and AGR-2 TRISO particles were plotted versus fast neutron fluence and irradiation temperature. In AGR-3/4 the buffer fracture rate was highest (23%) for an irradiation temperature of 1047°C and a fast fluence of 5.18E25 n/m 2 . Increasing the irradiation temperature to 1375°C reduced the buffer fracture rate to 14%. Reducing the irradiation temperature to 872°C and the fast fluence by a factor of 3 reduced the buffer fracture rate to 7%. The temperature and fluence dependencies observed for AGR-3/4 buffer fracture were consistent with those observed in AGR-2. Lower fluences and/or higher temperatures significantly reduced the buffer fracture frequencies. Lower buffer fracture frequencies were also observed at lower temperatures as long as the fluence was also significantly reduced. This is believed to be due to lower fluence resulting in less irradiation-induced dimensional change (shrinkage) of the buffer, and a higher temperature promoting enhanced creep relaxation of stresses within the buffer, leading to less buffer fracture.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗