Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “error rate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

Fiber optic rotation sensor /FORS/ signal detection and processing

The recent development of low-loss single-mode optical fiber waveguides for light has made possible a new class of inertial reference devices built on the principle of a closed loop interferometer. Light circulating through the loop in both directions experiences a relative phase delay proportional to rotation rate about the loop axis. This paper derives the phase delay and discusses signal detection, signal processing techniques and error sources. It is concluded that synchronous modulation and demodulation and an active gain control at the signal calculation level are required to eliminate drift errors. Potential performance is extraordinarily good; rotation rate sensitivity of a few milli-arc seconds per second and angular position random walk errors of an arc second per square root hour appear feasible.

Goss, W. C.↗

Collagen Turnover in Relation to Risk Factors and Hemodynamics in Human Intracranial Aneurysms

Determinants for molecular and structural instability, that is, impending growth or rupture, of intracranial aneurysms (IAs) remain uncertain. To elucidate this, we endeavored to estimate the actual turnover rates of the main molecular constituent in human IA (collagen) on the basis of radiocarbon ( 14 C) birth dating in relation to IA hemodynamics. Collagen turnover rates in excised human IA samples were calculated using mathematical modeling of 14 C birth dating data of collagen in relation to risk factors and histological markers for collagen maturity/turnover in selected IA. Hemodynamics were simulated using image-based computational fluid dynamics. Correlation, logistic regression, and receiver operating characteristic analyses were performed. Collagen turnover rates were estimated in 46 IA (43 patients); computational fluid dynamics could be performed in 20 IA (20 patients). The mean collagen turnover rate (γ) constituted 126% (±1% error) per year. For patients with arterial hypertension, γ was greater than 2600% annually, whereas γ was distinctly lower with 32% (±1% error) per year for patients without risk factors, such as smoking and hypertension. There was a distinct association between histological presence of rather immature collagen in human IA and the presence of modifiable risk factors. Spatial-temporal averaged wall shear stress predicted rapid collagen turnover (odds ratio, 1.6 [95% CI, 1.0–2.7]). Receiver operating characteristic analysis demonstrated a good test accuracy (area under the curve, 0.798 [95% CI, 0.598–0.998]) for average wall shear stress with a threshold ≥4.9 Pa for rapid collagen turnover. Our data indicate that turnover rates and stability of collagen in human IA are strongly associated with the presence of modifiable risk factors and aneurysmal hemodynamics. Finally, these findings underline the importance of strict risk factor modification in patients with unruptured IA. Future should include more detailed risk factor data to establish a more causal understanding of hemodynamics and the rupture risk of individual IA.

60 APPLIED LIFE SCIENCES↗

Severity of liver disease affects HCV kinetics in patients treated with intravenous silibinin monotherapy

HCV kinetic analysis and modeling during antiviral therapy have not been performed in decompensated cirrhotic patients awaiting liver transplantation. Here, viral and host parameters were compared in patients treated with daily intravenous silibinin (SIL) monotherapy for 7 days according to the severity of their liver disease. Data were obtained from 25 patients, 12 non-cirrhotic, 8 with compensated cirrhosis and 5 with decompensated cirrhosis. The standard-biphasic model with time-varying SIL effectiveness (from 0 to ε max ) was fit to viral kinetic data. Our results show that baseline viral load and age were significantly associated with the severity of liver disease (p<0.0001). A biphasic viral decline was observed in most patients with a higher first phase decline patients with less severe liver disease. The maximal effectiveness, ε max , was significantly (p≤0.032) associated with increasing severity of liver disease (ε max [s.e.]=0.86[0.05], ε max =0.69[0.06] and ε max =0.59[0.1]). The 2nd phase decline slope was not significantly different among groups (mean 1.88±0.15 log 10 IU/ml/wk, p=0.75) as was the rate of change of SIL effectiveness (k=2.12/day[standard error, SE=0.18/day]). HCV-infected cell loss rate (δ[SE]=0.62/day[0.05/day]) was high and similar among groups. We conclude that the high loss rate of HCV-infected cells suggests that sufficient dose and duration of SIL might achieve viral suppression in advanced liver disease.

59 BASIC BIOLOGICAL SCIENCES↗

Fast, automatic, and accurate catheter reconstruction in HDR brachytherapy using an electromagnetic 3D tracking system

Purpose: In high dose rate brachytherapy (HDR-B), current catheter reconstruction protocols are relatively slow and error prone. The purpose of this technical note is to evaluate the accuracy and the robustness of an electromagnetic (EM) tracking system for automated and real-time catheter reconstruction. Methods: For this preclinical study, a total of ten catheters were inserted in gelatin phantoms with different trajectories. Catheters were reconstructed using a 18G biopsy needle, used as an EM stylet and equipped with a miniaturized sensor, and the second generation Aurora{sup ®} Planar Field Generator from Northern Digital Inc. The Aurora EM system provides position and orientation value with precisions of 0.7 mm and 0.2°, respectively. Phantoms were also scanned using a μCT (GE Healthcare) and Philips Big Bore clinical computed tomography (CT) system with a spatial resolution of 89 μm and 2 mm, respectively. Reconstructions using the EM stylet were compared to μCT and CT. To assess the robustness of the EM reconstruction, five catheters were reconstructed twice and compared. Results: Reconstruction time for one catheter was 10 s, leading to a total reconstruction time inferior to 3 min for a typical 17-catheter implant. When compared to the μCT, the mean EM tip identification error was 0.69 ± 0.29 mm while the CT error was 1.08 ± 0.67 mm. The mean 3D distance error was found to be 0.66 ± 0.33 mm and 1.08 ± 0.72 mm for the EM and CT, respectively. EM 3D catheter trajectories were found to be more accurate. A maximum difference of less than 0.6 mm was found between successive EM reconstructions. Conclusions: The EM reconstruction was found to be more accurate and precise than the conventional methods used for catheter reconstruction in HDR-B. This approach can be applied to any type of catheters and applicators.

60 APPLIED LIFE SCIENCES↗

Feasibility Study of Two Candidate Reaction Wheel/thruster Hybrid Control Architecture Designs for the Cassini Spacecraft

As the first spacecraft to achieve orbit at Saturn in 2004, Cassini has collected science data throughout its four-year prime mission (2004-08), and has since been approved for a first and second extended mission through 2017. Cassini carries a set of three "fixed" reaction wheels and a backup reaction wheel (reaction wheel #4) is mounted on top of an articulable platform. If necessary, this platform could be articulated to orient the backup reaction wheel with the degraded wheel. The reaction wheels are used primarily for attitude control when precise and stable pointing of a science instrument such as the narrow angle camera is required. In 2001-02, reaction wheel #3 exhibited signs of bearing cage instability. As a result, reaction wheel #4 was articulated to align with reaction wheel #3. Beginning in July 2003, Cassini was controlled using wheel #1, #2, and #4. From their first use in the spring of 2000 until today, reaction wheels #1 and #2 have accumulated more than3.5 billions revolutions each. As such, in spite of very carefully management of the wheel spin rates by the mission operation team, there are some observed increases in the drag torque of the wheels' bearings. Hence, the mission operations team must prepare for the contingency scenario in which the reaction wheel #1 (in addition to wheel #3) had degraded. In this hypothetical fault scenario, the two remaining reaction wheels (#2 and #4) will not be able to provide precise and stable three-axis control of the spacecraft. In this study, we evaluate the feasibility of controlling Cassini using the two remaining reaction wheels and four thrusters to meet the science pointing requirements for two key science operational modes: the Optical Remote Sensing and Downlink, Fields, Particles, & Waves operation modes. The performance (e.g., pointing control error, pointing stability, hydrazine consumption rate, etc.) of the hybrid controllers in both operations scenarios will be compared with those achieved using an all-thruster controller design. Strength and weaknesses of the hybrid control architecture are assessed quantitatively.

Cassini↗

Radiochromic film based transit dosimetry for verification of dose delivery with intensity modulated radiotherapy

Purpose: To evaluate the transit dose based patient specific quality assurance (QA) of intensity modulated radiation therapy (IMRT) for verification of the accuracy of dose delivered to the patient. Methods: Five IMRT plans were selected and utilized to irradiate a homogeneous plastic water phantom and an inhomogeneous anthropomorphic phantom. The transit dose distribution was measured with radiochromic film and was compared with the computed dose map on the same plane using a gamma index with a 3% dose and a 3 mm distance-to-dose agreement tolerance limit. Results: While the average gamma index for comparisons of dose distributions was less than one for 98.9% of all pixels from the transit dose with the homogeneous phantom, the passing rate was reduced to 95.0% for the transit dose with the inhomogeneous phantom. Transit doses due to a 5 mm setup error may cause up to a 50% failure rate of the gamma index. Conclusions: Transit dose based IMRT QA may be superior to the traditional QA method since the former can show whether the inhomogeneity correction algorithm from TPS is accurate. In addition, transit dose based IMRT QA can be used to verify the accuracy of the dose delivered to the patient during treatment by revealing significant increases in the failure rate of the gamma index resulting from errors in patient positioning during treatment.

60 APPLIED LIFE SCIENCES↗

Toward an organ based dose prescription method for the improved accuracy of murine dose in orthovoltage x-ray irradiators

Purpose: Accurate dosimetry is essential when irradiating mice to ensure that functional and molecular endpoints are well understood for the radiation dose delivered. Conventional methods of prescribing dose in mice involve the use of a single dose rate measurement and assume a uniform average dose throughout all organs of the entire mouse. Here, the authors report the individual average organ dose values for the irradiation of a 12, 23, and 33 g mouse on a 320 kVp x-ray irradiator and calculate the resulting error from using conventional dose prescription methods. Methods: Organ doses were simulated in the Geant4 application for tomographic emission toolkit using the MOBY mouse whole-body phantom. Dosimetry was performed for three beams utilizing filters A (1.65 mm Al), B (2.0 mm Al), and C (0.1 mm Cu + 2.5 mm Al), respectively. In addition, simulated x-ray spectra were validated with physical half-value layer measurements. Results: Average doses in soft-tissue organs were found to vary by as much as 23%–32% depending on the filter. Compared to filters A and B, filter C provided the hardest beam and had the lowest variation in soft-tissue average organ doses across all mouse sizes, with a difference of 23% for the median mouse size of 23 g. Conclusions: This work suggests a new dose prescription method in small animal dosimetry: it presents a departure from the conventional approach of assigninga single dose value for irradiation of mice to a more comprehensive approach of characterizing individual organ doses to minimize the error and uncertainty. In human radiation therapy, clinical treatment planning establishes the target dose as well as the dose distribution, however, this has generally not been done in small animal research. These results suggest that organ dose errors will be minimized by calibrating the dose rates for all filters, and using different dose rates for different organs.

54 ENVIRONMENTAL SCIENCES↗

Photolysis rates based on Schumann-Runge band approximations and irradiance measurements

The photolysis rate (J3) for CF2Cl2(F-12) in the stratosphere has been computed for three altitudes using measured solar fluxes from a balloon borne spectrometer. The rate is compared with that obtained by computing the attenuated flux using effective cross sections appropriate for the Schumann-Runge bands (J1) (Allen and Frederick, 1982). The result shows that the error in the F-12 photolysis rate caused by using the Allen and Frederick approximation is about 10 percent (J1 less than J3) for altitudes between 32 and 38 km with solar zenith angles less than about 62 degrees. For species other than O2, this implies that the discrepancy in photolysis rates associated with the Schumann-Runge band approximations are not likely to be important. Within the Schumann-Runge band region the computed errors for F-12 photolysis are about 10.5 percent at 38.13 km and increase with decreasing altitude. If this error applies to O2 photolysis, there may be the possibility of an incorrect calculation of net odd oxygen production in photochemical models.

Herman, J. R.↗

Numerical Issues Associated with Compensating and Competing Processes in Climate Models: an Example from ECHAM-HAM

The purpose of this paper is to draw attention to the need for appropriate numerical techniques to represent process interactions in climate models. In two versions of the ECHAM-HAM model, different time integration methods are used to solve the sulfuric acid (H2SO4) gas evolution equation, which lead to substantially different results in the H2SO4 gas concentration and the aerosol nucleation rate. Using convergence tests and sensitivity simulations performed with various time stepping schemes, it is confirmed that numerical errors in the second model version are significantly smaller than those in version one. The use of sequential operator splitting in combination with long time step is identified as the main reason for the large systematic biases in the old model. The remaining errors in version two in the nucleation rate, related to the competition between condensation and nucleation, have a clear impact on the simulated concentration of cloud condensation nuclei in the lower troposphere. These errors can be significantly reduced by employing an implicit solver that handles production, condensation and nucleation at the same time. Lessons learned in this work underline the need for more caution when treating multi-time-scale problems involving compensating and competing processes, a common occurrence in current climate models.

climate↗

Phobos Ephemeris Improvement from Recent Spacecraft Observations

Despite 127 years of observations, there is still room for improvement in the ephemeris of the Martian satellite Phobos. Early in this history, Earth-based astrometric observations of Phobos and Deimos were used to estimate the mass and oblateness of Mars. As more data accumulated, it became clear that a secular acceleration in the longitude of Phobos was occurring, and this was attributed to tidal dissipation within Mars, yielding rough estimates of the tidal quality factor, or Q. At the epoch of the earliest spacecraft observations of Phobos, from Mariner 9 and the Viking Orbiters and Landers, the gravitational field of Mars, and resulting forces on Phobos, were still not particularly well known. Thus observations of natural and artificial satellite motions continued to contribute, each in their own way, to knowledge of the mass distribution within Mars. Improvements in tracking system accuracy, and the placement of satellites, like the 1996 Mars Global Surveyor and 2001 Mars Odyssey, in circular polar orbits has lead to dramatic improvements to knowledge of the Mars gravity field. The direct gravitational influence on Phobos is no longer expected to be a limiting factor in predicting its orbital motion. Despite that progress, a variety of observations of Phobos from recent orbiters and landers suggest that the best satellite ephemeris still has along-track orbit errors which are accumulating at a rate of 1.75 kilometers per year, with Phobos gaining on the predicted positions. These recent observations alone do not span sufficient time to separately resolve the positional error into changes in mean motion and changes in secular acceleration. However, combining them with earlier observations will allow improvements in both the mean motion and its first derivative. This latter parameter is particularly interesting, as it relates to tidal dissipation, and thus uniquely constrains the internal structure of Mars. The current best estimate of the secular acceleration rate of Mars implies a surprisingly low value for the tidal dissipation factor Q = (94 plus or minus 1). For the Earth, most tidal dissipation occurs within the oceans. The terrestrial mantle tidal Q is 280. An issue of interest is then: why, where, and how does Mars dissipate tidal energy so effectively.

Bills, B. G.↗

Stochastic Richardson Extrapolation Based Numerical Error Estimation for Kinetic Plasma Simulations

We present a numerical error estimation technique specifically formulated to deal with stochastic code output with multiple discretization parameters. This method is based on multiple fits to an error model with arbitrary convergence rates and cross-coupling terms, performed using nonlinear optimization. The fitting approach varies by the type of residual norm which influences the importance of outliers, and weights which influences the relative importance of data points in the coarse and refined regions of discretization parameter space. To account for the influence of stochastic noise, these fits are performed on multiple bootstrap values based on the underlying response data set. Using an automated discretization domain selection scheme, the fits are performed on a series of reduced sets of discretization levels in order to find an optimal fully-converged result estimate in the minimum variance sense; this automated approach enables straightforward analysis of multiple quantities of interest and/or time and spatially-dependent response data. The overall numerical error analysis method is useful for verification and validation problems for stochastic simulation methods and forms a key component in the overall uncertainty quantification process. The method was demonstrated for steady and unsteady electron diode problems simulated using a particle-in-cell kinetic plasma code, demonstrating excellent results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Seven Years of ACTS Technology Verification Experiments Reviewed

The Advanced Communications Technology Satellite (ACTS) was designed to achieve a 99.5-percent system availability rate and signals with less than one error in 10(exp 7) bits throughout the continental United States. To accomplish such a high rate of system availability, ACTS uses multiple narrow hopping beams and very small aperture terminal (VSAT) technology. In addition, ACTS uses an adaptive rain fade compensation protocol to reduce the negative effects of propagation on the system. To enhance knowledge on how propagation and system variances affect system availability, researchers at the NASA Glenn Research Center at Lewis Field performed technology verification experiments over a 7-yr period (from September 1993 to the present). These experiments include T1VSAT System Availability, Statistical Rain Fade Compensation Characterization, Statistical Characterization of Ka-Band Propagation Effects on Communication Link Performance, and Multibeam Antenna Performance.

Acosta, Roberto J.↗

Dosimetric effects of multileaf collimator leaf width on intensity-modulated radiotherapy for head and neck cancer

Purpose: The authors evaluated the effects of multileaf collimator (MLC) leaf width (2.5 vs. 5 mm) on dosimetric parameters and delivery efficiencies of intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) for head and neck (H and N) cancers. Methods: The authors employed two types of mock phantoms: large-sized head and neck (LH and N) and small-sized C-shape (C-shape) phantoms. Step-and-shoot IMRT (S and S-IMRT) and VMAT treatment plans were designed with 2.5- and 5.0-mm MLC for both C-shape and LH and N phantoms. Their dosimetric characteristics were compared in terms of the conformity index (CI) and homogeneity index (HI) for the planning target volume (PTV), the dose to organs at risk (OARs), and the dose-spillage volume. To analyze the effects of the field and arc numbers, 9-field IMRT (9F-IMRT) and 13-field IMRT (13F-IMRT) plans were established for S and S-IMRT. For VMAT, single arc (VMAT{sub 1}) and double arc (VMAT{sub 2}) plans were established. For all plans, dosimetric verification was performed using the phantom to examine the relationship between dosimetric errors and the two leaf widths. Delivery efficiency of the two MLCs was compared in terms of beam delivery times, monitor units (MUs) per fraction, and the number of segments for each plan. Results: 2.5-mm MLC showed better dosimetric characteristics in S and S-IMRT and VMAT for C-shape, providing better CI for PTV and lower spinal cord dose and high and intermediate dose-spillage volume as compared with the 5-mm MLC (p < 0.05). However, no significant dosimetric benefits were provided by the 2.5-mm MLC for LH and N (p > 0.05). Further, beam delivery efficiency was not observed to be significantly associated with leaf width for either C-shape or LH and N. However, MUs per fraction were significantly reduced for the 2.5-mm MLC for the LH and N. In dosimetric error analysis, absolute dose evaluations had errors of less than 3%, while the Gamma passing rate was greater than 95% according to the 3%/3 mm criteria. There were no significant differences in dosimetric error between the 2.5- and 5-mm MLCs. Conclusions: As compared with MLC of 5-mm leaf widths, MLC with finer leaf width (2.5-mm) can provide better dosimetric outcomes in IMRT for C-shape. However, the MLC leaf width may only have minor effects on dosimetric characteristics in IMRT for LH and N. The results of the present study will serve as a useful assessment standard when assigning or introducing equipment for the treatment of H and N cancers.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

State-Space Model to Estimate Salmon Escapement Using Multiple Data Sources

Abstract Accurate estimates of salmonids passing Lower Granite Dam on the Snake River, by species and origin, are a critical input to assessing the status and trends of various populations as well as successful management of fisheries in the Snake River basin. Here, we describe a state-space model that estimates such escapement past a dam by using window counts, PIT tag observations, and data from an adult fish trap, accounting for issues such as nighttime passage, fallback and reascension, potential observation error at the window, and uncertainty in the adult trap rate. We tested the approach using a simulation framework that mimicked several levels of observation error, differences between nighttime passage and reascension rates, and the possibility of the adult trap being closed for some period of time. Our results demonstrate that the model produced unbiased estimates across all tested scenarios. We also applied this model to empirical data from Lower Granite Dam to produce estimates of wild, clipped hatchery, and unclipped hatchery spring/summer-run Chinook Salmon Oncorhynchus tshawytscha and steelhead O. mykiss from spawn years 2010–2019.

See, Kevin E. (ORCID:0000000297626442)↗

Design and evaluation of a robust dynamic neurocontroller for a multivariable aircraft control problem

The design of a dynamic neurocontroller with good robustness properties is presented for a multivariable aircraft control problem. The internal dynamics of the neurocontroller are synthesized by a state estimator feedback loop. The neurocontrol is generated by a multilayer feedforward neural network which is trained through backpropagation to minimize an objective function that is a weighted sum of tracking errors, and control input commands and rates. The neurocontroller exhibits good robustness through stability margins in phase and vehicle output gains. By maintaining performance and stability in the presence of sensor failures in the error loops, the structure of the neurocontroller is also consistent with the classical approach of flight control design.

Troudet, T.↗

Design and evaluation of a robust dynamic neurocontroller for a multivariable aircraft control problem

The design of a dynamic neurocontroller with good robustness properties is presented for a multivariable aircraft control problem. The internal dynamics of the neurocontroller are synthesized by a state estimator feedback loop. The neurocontrol is generated by a multilayer feedforward neural network which is trained through backpropagation to minimize an objective function that is a weighted sum of tracking errors, and control input commands and rates. The neurocontroller exhibits good robustness through stability margins in phase and vehicle output gains. By maintaining performance and stability in the presence of sensor failures in the error loops, the structure of the neurocontroller is also consistent with the classical approach of flight control design.

Troudet, T.↗

Global Vertical Rates from VLBl

The analysis of global VLBI observations provides vertical rates for 50 sites with formal errors less than 2 mm/yr and median formal error of 0.4 mm/yr. These sites are largely in Europe and North America with a few others in east Asia, Australia, South America and South Africa. The time interval of observations is up to 20 years. The error of the velocity reference frame is less than 0.5 mm/yr, but results from several sites with observations from more than one antenna suggest that the estimated vertical rates may have temporal variations or non-geophysical components. Comparisons with GPS rates and corresponding site position time series will be discussed.

Ma, Chopo↗

Numerical and boundary condition effects on the prediction of detonation engine behavior using detailed numerical simulations

High-fidelity numerical simulations of an experimental rotating detonation engine with discrete fuel/air injection were conducted. A series of configurations with different feed-plenum pressures but with constant equivalence ratio were studied. Detailed chemical kinetics for the hydrogen/air system is used. A resolution study for the full rotating detonation engine (RDE) system simulation is also conducted. Two kinds of boundary conditions, a total pressure boundary and a constant mass flow rate boundary, are used to assess the effects of the inlet boundary. As mass flow rate is increased, the total pressure boundary causes more error in the axial pressure distribution while the constant mass flow rate gives a better solution for all cases ran. The simulations confirm experimental findings, and reproduce qualitative as well as some of the quantitative trends. These results demonstrate that a) fuel-air mixing is highly non-uniform within the detonation chamber, leading to variations in local equivalence ratio, b) the fuel and oxidizer injectors experience significant backflow as the detonation wave passes over, but recover at different rates which further augments the inefficiencies in mixing, and c) parasitic combustion in the mixing region makes the detonation wave weak by extending the reaction zone across the wave.

33 ADVANCED PROPULSION SYSTEMS↗