Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “enthalpy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

Thermodynamic properties of calcium-bismuth alloys determined by emf measurements

The thermodynamic properties of Ca-Bi alloys were determined by electromotive force (emf) measurements to assess the suitability of Ca-Bi electrodes for electrochemical energy storage applications. Emf was measured at ambient pressure as a function of temperature between 723 K and 1173 K using a Ca(s)vertical bar CaF2(s)vertical bar Ca(in Bi) cell for twenty different Ca-Bi alloys spanning the entire range of composition from chi(Ca) = 0 to 1. Reported are the temperature-independent partial molar entropy and enthalpy of calcium for each Ca-Bi alloy. Also given are the measured activities of calcium, the excess partial molar Gibbs energy of bismuth estimated from the Gibbs-Duhem equation, and the integral change in Gibbs energy for each Ca-Bi alloy at 873 K, 973 K, and 1073 K. Calcium activities at 973 K were found to be nearly constant at a value a(Ca) = 1 x 10(-8) over the composition range chi(Ca) = 0.32-0.56, yielding an emf of similar to 0.77 V. Above chi(Ca) = 0.62 and coincident with Ca5Bi3 formation, the calcium activity approached unity. The Ca-Bi system was also characterized by differential scanning calorimetry over the entire range of composition. Based upon these data along with the emf measurements, a revised Ca-Bi binary phase diagram is proposed. (C) 2011 Elsevier Ltd. All rights reserved.

Kim, H↗

Determination and modeling of the thermodynamic properties of liquid calcium-antimony alloys

The thermodynamic properties of Ca-Sb alloys were determined by emf measurements in a cell configured as Ca(s)vertical bar CaF2 vertical bar Ca-Sb over the temperature range 550-830 degrees C. Activity coefficients of Ca and Sb, enthalpy, Gibbs free energy, and entropy of mixing of Ca-Sb alloys were calculated for xc(a) < 0.55. To explain the connection between short-range order of liquid Ca-Sb alloys and the strong deviation from ideality in the thermodynamic properties, two thermodynamic models were invoked and reconciled: the regular associated solution model, assuming the presence of a CaSb2 associate, and the molecular interaction volume model (MIVM). For the first time, the MIVM was used successfully to model the activity coefficients of a system with high-melting intermetallics, reducing the number of fitting parameters necessary from 5 (regular associated model) to 2 (MIVM). From the interaction parameters optimized by fitting at 800 degrees C, the with an average error of less than value. (C) 2012 Elsevier Ltd. All rights reserved,

Poizeau, S↗

Contribution of Metal-Organic-Heat Carrier nanoparticles in a R245fa low-grade heat recovery Organic Rankine Cycle

This paper presents an in-depth investigation of the applications of an innovative nanofluid – suspensions of nanoparticles in a base fluid- in the ORC field, based on a new class of nanoparticles – termed Metal-Organic Heat Carriers (MOHCs) – molecularly engineered to reversibly uptake and release the working fluid molecules in which they are suspended. Unlike standard nanoparticles (i.e. Al2O3, Al, …), these MOHCs make it possible to extract additional heat from the endothermic enthalpy of desorption which can be as much as twice the level of the latent heat of vaporization of the pure fluid phase alone. The paper illustrates the development of a numerical model for assessing the MOHC-based nanofluid gain in ORC systems. More specifically, the possible combination of the base fluid R245fa with the nanoparticle MIL101, a robust Metal Organic Heat Carrier, was considered. To properly model the reversible adsorption/desorption process, experimental analyses were carried out to study the uptake of the R245fa in MIL101 at different operating conditions and departing from the experimental results, proper semi-empirical correlations were defined and adopted within the numerical model. The resulting performance of the MIL101/R245fa were compared with those of pure organic fluids, whose cycle was optimized in order to maximize the area-to-power ratio. Promising results were achieved in terms of system efficiency increase and heat exchanger area reduction.

Cavazzini, Giovanna↗

Energy-efficient sorption-based gas clothes dryer systems

Standard electric resistance and fuel-driven dehydration technologies exhibit a maximum coefficient of performance of well below 1 mainly due to enthalpy losses associated with the air leaving the dehydration system. To improve energy efficiency, condensing dryer systems condense the moisture captured from a product in a closed-loop air circulation cycle. Existing condensing dehydration systems including heat pump dryers, however, need to significantly cool the air to achieve dehumidification. The added cooling and subsequent heating to return the air to a desired drying temperature consume substantial energy and thus reduce drying performance. Here, an innovative sorption-based gas dehydration system is proposed to overcome barriers deteriorating energy efficiency in existing gas, electric, or heat pump dryer systems. Decoupling latent and sensible loads, the system employs a liquid-desiccant solution to directly capture air humidity, thereby allowing circulation of the air in a closed loop to achieve high drying energy efficiency. In other words, the system captures waste latent heat from the moisture produced during the dehydration process and reuses it to improve energy efficiency. This study focuses on a comprehensive quasi-steady-state thermodynamic modeling of the proposed sorption-based dehydration concept employed for a gas clothes dryer application to predict transient response and overall drying performance (i.e., time and energy metrics). The analysis indicates the proposed sorption-based gas clothes dryer system can deliver a specific moisture extraction rate of 1.71 kg of water per kWh (i.e., a combined energy factor of 3.167 kg (6.98 lbm) of dry cloth per kWh) with a drying time of 44 min. This is a 112% energy improvement compared with state-of-the-art gas clothes dryers exhibiting a combined energy factor of 1.50 kg (3.3 lbm) of dry cloth per kWh. The technology pursued here can potentially be employed as a platform for many fuel-driven equipment to take advantage of available waste thermal energy in the environment instead of simply burning a fuel.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A comprehensive modeling of falling film evaporators subject to vapor flow, pass arrangements, and refrigerants

Improving the heat transfer performance of falling film evaporators is a crucial step for improving the energy efficiency of the heat pump or refrigeration systems. This study conducts a numerical investigation for the practical-scale falling film evaporator based on the epsilon–NTU method with an updated heat transfer correlation. The algorithm was validated with lab-scale and real-scale falling film evaporator experimental results, and the prediction reaches a mean absolute deviation of 12.5%. Here, the parametric study encompasses eight refrigerants: R-134a, R-410A, R-600a, R-717, R-1270, R-152a, R-1234yf, and R-1234ze(E). The results indicate that vaporization enthalpy of refrigerant is a key property in selecting an appropriate working fluid because it helps minimize severe heat transfer degradation caused by dry-out. Additionally, the vapor-flow–induced heat transfer degradation can be predicted using the critical Weber number. Furthermore, the trade-off between extending the tube length and increasing the number of tubes for heat transfer improvement is discussed. Finally, different two-pass arrangements show deviations of less than 4 %.

Dry-out↗

Goldilocks and the three glymes: How Na+ solvation controls Na–O 2 battery cycling

In this work we report a framework to understand the role of solvent-salt interactions and how they mediate the performance of sodium-air/O 2 batteries. The utilization of suitable electrolyte materials remains a point of major concern within the research community, as their stability and decomposition pathways during cycling are intimately connected with capacity and cycle life. Glyme based solvents have been widely utilized in Na–O 2 batteries, however, to date no clear correlation between solvent/electrolyte properties and battery performance has been given. Herein, we have examined the effect of glyme chain length (ethylene glycol dimethyl ether DME; diethylene glycol dimethyl ether, DEGDME; and tetraethylene glycol dimethyl ether, TEGME) on the cycling behaviour of Na–O 2 batteries and conclude that overall cell performance is highly dependent on solvent selection, salt concentration and rate of discharge/charge. We demonstrate how solvent selection helps define cell chemistry and performance by linking salt-solvent interactions to enthalpy of dissolution - and subsequently to sodium battery electrolyte properties - through the combination of both experimental and theoretical methodologies. The approaches detailed in this study could be used to predictively prepare electrolytes for Li-air batteries, other glyme-based electrochemical systems and low temperature applications.

25 ENERGY STORAGE↗

Molecular investigation on the binding of Cd(II) by the binary mixtures of montmorillonite with two bacterial species

Bacteria and phyllosilicate commonly coexist in the natural environment, producing various bacteria–clay complexes that are capable of immobilizing heavy metals, such as cadmium, via adsorption. However, the molecular binding mechanisms of heavy metals on these complex aggregates still remain poorly understood. This study investigated Cd adsorption on Gram-positive B. subtilis, Gram-negative P. putida and their binary mixtures with montmorillonite (Mont) using the Cd K-edge x-ray absorption spectroscopy (XAS) and isothermal titration calorimetry (ITC). We observed a lower adsorptive capacity for P. putida than B. subtilis, whereas P. putida–Mont and B. subtilis–Mont mixtures showed nearly identical Cd adsorption behaviors. EXAFS fits and ITC measurements demonstrated more phosphoryl binding of Cd in P. putida. The decreased coordination of C atoms around Cd and the reduced adsorption enthalpies and entropies for the binary mixtures compared to that for individual bacteria suggested that the bidentate Cd-carboxyl complexes in pure bacteria systems were probably transformed into monodentate complexes that acted as ionic bridging structure between bacteria and motmorillonite. This study clarified the binding mechanism of Cd at the bacteria–phyllosilicate interfaces from a molecular and thermodynamic view, which has an environmental significance for predicting the chemical behavior of trace elements in complex mineral–organic systems.

54 ENVIRONMENTAL SCIENCES↗

A mechanistic study on Decontamination of Methyl Orange Dyes from Aqueous Phase by Mesoporous Pulp Waste and Polyaniline

The dispersion-corrected density functional theory (DFT-D3) is used to investigate the mechanism of mesoporous pulp waste (MPW) and polyaniline (PANI) adsorptive removal methyl orange (MO) dye from their aqueous solutions. The results are absolutely reliable because of the sufficiently accurate method although such big systems are studied. It is demonstrated that hydrogen bond and Van Der Waals interactions play a significant role in MO adsorption by MPW and PANI. For MO adsorption by MPW, hydrogen bond and Van Der Waals interactions are both weakened in S{sub 1} state. In contrast, hydrogen bond and Van Der Waals interactions between PANI and MO are both enhanced in S{sub 1} state. The thermodynamic parameters such as enthalpy and free energy change reveal that the MO adsorption by MPW and PANI are spontaneous and exothermic. The adsorption of MO on MPW is less favorable in S{sub 1} state and the adsorption of MO on PANI is more favorable in S{sub 1} state. Therefore, the photoexcitation should be controlled during the MO adsorption by MPW and applied for MO adsorption by PANI. - Highlights: • The hydrogen bond and Van Der Waals interactions play a significant role in MO adsorption by MPW and PANI. • The influence of photoexcitation on adsorption has been studied firstly in our work. • The adsorption of MO on MPW is less favorable in S{sub 1} state and the adsorption of MO on PANI is more favorable in S{sub 1} state. • The MO adsorption by MPW and PANI are spontaneous and exothermic.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Phase change material-to-refrigerant heat exchangers: Experimental validation and uneven melting analysis

Thermal energy storage (TES) using phase change materials (PCMs) enables load shifting and reduces mismatches between the building's thermal demand and the heat pump (HP) system's thermal capacity. While most TES studies have focused on single-phase heat transfer fluids, PCM-to-refrigerant heat exchangers (PRHX), in which the refrigerant undergoes liquid-vapor phase change, remain largely underexplored. Here, to address this gap, this study systematically investigates a shell-and-tube PRHX operating as the condenser in an HP through experiments and simulations. A two-dimensional enthalpy-based finite-volume PRHX model was developed and validated against experimental data, including refrigerant and PCM temperature profiles, PRHX capacity, and system-level performance. Results show three characteristic stages: Stage I, the condenser temperature rapidly increases with PCM in the solid state absorbing sensible heat; Stage II, stable operation during PCM phase change; and Stage III, performance decline once part of the PCM becomes fully melted. Heat transfer analysis revealed that uneven PCM melting along the condenser length was driven primarily by variations in the refrigerant-side heat transfer coefficient, rather than local approach temperature differences. Further study demonstrated that minimizing refrigerant outlet subcooling led to more uniform PCM melting and extended Stages I and II by up to 89%. This paper provides a validated PRHX model, clarifies the mechanisms of uneven PCM melting, and highlights subcooling control as an effective strategy to improve TES performance in HP systems without requiring secondary loops.

Graphite matrix↗

Combustion dynamics linked to flame behaviour in a partially premixed swirled industrial burner

Previous work [Biagioli, F., Stabilization mechanism of turbulent premixed flames in strongly swirled flows, Combustion, Theory and Modelling 10 (3) (2006) 389-412; Guethe, F., Lachner, R., Schuermans, B., Biagioli, F., Geng, W., Inauen, A., Schenker, S., Bombach, R., Hubschmid, W., Flame imaging on the ALSTOM EV-burner: thermo acoustic pulsations and CFD-validation, in: AIAA Paper 2006-437 presented at the 44th AIAA Aerospace Sciences Meeting and Exhibit, Reno, Nevada, January 9-12, 2006] has shown that turbulent dry low NO{sub x} (partially premixed) flames in high swirl conical burners may be subject to a large change of their anchoring location at the symmetry axis when a critical value of the bulk equivalence ratio is reached, i.e. they are bi-stable. This flame behavior is linked here to combustion pressure dynamics measured in an atmospheric test rig for a prototype version of the Alstom EnVironmental (EV) conical burner. The link is made via the solution of the problem of the 'travelling flameholder', which shows that the unsteady displacement of the flame anchoring location implies an unsteady variation of the flame surface area and therefore unsteady heat release. The relevance of this source of unsteady heat release - which is different from more usual ones due to variations in turbulent burning rate and in the sensible enthalpy jump across the flame - to the generation of combustion dynamics in strongly swirled flows is confirmed here by the strong positive correlation between the tendency of the flame to be displaced and the measured amplitude of pressure pulsations. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Solubilities of six lithium salts in five non-aqueous solvents and in a few of their binary mixtures

Solubilities were measured from 25 to 45 °C for six lithium salts (LiF, LiCl, LiBr, LiNO 3 , LiTFSI and LiPF 6 ) in five pure non–aqueous solvents (ethanol, acetonitrile, dimethyl carbonate, dimethyl sulfoxide and propylene carbonate) and in a few of their binary mixtures (ethanol + DMSO, DMC + DMSO and DMC + PC). The experimental method uses a Varian inductively–coupled plasma–optical–emission spectrometer (ICP–OES). Solubilities increase with rising temperature. At a given temperature, LiNO 3 shows the highest solubility in all solvents. Salt solubilities follow the order LiNO 3 > LiTFSI > LiBr > LiCl > LiPF 6 > LiF. The dissolving abilities of the solvents are in the order ethanol > DMSO > acetonitrile > PC > DMC. Finally, coupled with the salt's melting temperature and enthalpy of fusion, liquid–phase activity coefficients for salts were obtained from the solubility data.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Computing the solubility of argon and xenon in molten sodium chloride and potassium chloride salts

Molten salt reactors (MSRs) offer significant advancements in nuclear reactor safety and efficiency by operating at higher temperatures and lower pressures compared to traditional reactors. A critical aspect of MSR operation involves understanding the solubility of fission byproducts, particularly noble gases, in the molten salts used. This study employs molecular dynamics (MD) simulations to compute Henry’s law constants and enthalpies of solvation for argon and xenon in molten sodium chloride (NaCl) and potassium chloride (KCl). We developed a new pairwise potential for the noble gas and salt interactions based on first principles calculations. We then used this potential to calculate Henry’s law constants of the two gases in the molten salts, which were modeled using both a rigid ion model (RIM) and a polarizable ion model (PIM). The solubility calculations, performed using the Widom insertion method, show qualitative agreement with limited experimental data, highlighting the temperature dependence and greater solubility of both gases in KCl compared to NaCl. Additionally, free volume analysis elucidated the role of available space within the molten salts in governing solubility trends. Our findings suggest that PIM trajectories provide more reliable predictions for noble gas solubility than RIM due to their accurate density representation. Furthermore, these results enhance understanding of gas solubility in MSR environments, and the methods can be readily extended to other systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Tailoring the rheological properties of high protein suspension by thermal-mechanical treatment

The viscoelasticity of concentrated protein suspensions associates closely with the mixing efficiency and cleaning frequency of facility during high-protein food development. This study investigated the effects of thermal-mechanical treatment on the viscoelasticity of milk protein isolate (MPI) suspensions and their underlying mechanisms to develop protein ingredient with low viscoelasticity. MPI suspensions (20%) were treated at 25, 50 and 85°C for 10-60 min under constant shear (100 s -1 ), followed by storage at 4°C. The viscosity (η) of MPI suspension treated at 50°C and 85°C was similar to 1-10% as those treated at 25 ° C. After four days of storage at 4°C, η showed the least value in 50°C-treated samples compared to those at 25 ° C and 85 ° C. The η and storage modulus (G') was decreased with prolonged treatment at 25 and 50°C, whereas opposite trend was found in 85°C treated samples. Differential scanning calorimetry found proteins in 50°C treated samples had smaller enthalpy than those in the control and 25°C treated samples. Protein surface hydrophobicity was increased slightly from 25°C to 50°C, but remarkably in 85°C treated samples. Ultra-small angle x-ray scattering showed the radius of gyration (R-g) of casein micelle was similar to 38 nm at 25°C and 50°C treated samples but increased to similar to 44 nm 85°C treated samples with reduced compactness. A new sphere-like structure with R-g of 18 nm was generated in 85°C treated samples. These findings suggested modulating temperature during thermal-mechanical treatment is essential to alter protein structures and morphology for desirable rheological properties.

59 BASIC BIOLOGICAL SCIENCES↗

Reexamining supercritical gas adsorption theories in nano-porous shales under geological conditions

Adsorption is an important phenomenon in surface chemistry, especially for nano-porous shales. In the shale gas-in-place, adsorbed gas could contribute up to 85%. However, adsorption is hard to quantitatively characterize due to different adsorption mechanisms, patterns, surfaces, and pore sizes. Moreover, key thermodynamic parameters, such as the enthalpy of adsorption, are challenging to determine due to uncertainties in adsorbed gas densities used in constructing absolute isotherms. In this paper, we revisit the Brunauer, Emmett, and Teller (BET) model, analytically simplify Ono-Kondo (OK) models for subsurface shales, and compare commonly used mono- and multilayer adsorption models (e.g., Langmuir, supercritical Dubinin-Radushkevich (SDR), supercritical BET (SBET), and simplified OK (OKs) models) with recently proposed pressure-dependent adsorption densities to develop a practical and reliable methodology that can be used in the supercritical state, typical for subsurface black shale conditions.Three independent data sets were used for nitrogen and methane adsorption isotherms at different temperatures. Furthermore, we demonstrate that adsorption predicted by the SDR model is comparable or lower than that predicted by the SBET model, but higher than the amounts predicted by Langmuir and OK models. The nitrogen BET method tends to underestimate the accessible SSA for methane. Measurement of isosteric heat of adsorption is suggested instead of the experimental fitting method, due to the significant difference between the calculated results by two commonly used methods. Experimental fitting and simulation methods are also briefly reviewed to guide future research on shale gas adsorption.

58 GEOSCIENCES↗

Thermodynamic modeling of MDEA(aq)-NH 3 (aq)-K 2 CO 3 (aq)-CO 2 (aq) using the Extended UNIQUAC model

Here, the development of advanced processes for carbon dioxide capture requires reliable thermodynamic models to ensure accurate process design. This work presents an optimized parameter set of the Extended UNIQUAC model for advanced mixed solvent solutions containing CO 2 -MDEA-NH 3 -K 2 CO 3 in water. The model was parameterized using vapor–liquid equilibrium, pure component saturation pressure, excess enthalpy, heat of absorption, molar heat capacity, apparent molar heat capacity, and solid–liquid equilibrium. These thermal and equilibrium properties cover temperatures between 253.6 K to 600 K and pressures up to 75.6 bar. The current model represents an extension of previous versions that were suitable for modeling aqueous NH 3 and K 2 CO 3 solutions. This parametrization accounts for molecular interactions between MDEA and these two components, which allows for the design of advanced capture processes. This paper demonstrates that the new model parameters are valid within the range of operational conditions typically found in CO 2 capture processes.

42 ENGINEERING↗

Cooperation between bound waters and hydroxyls in controlling isotope-exchange rates

Exposed and bound waters on minerals differ from aqueous ions in that they are often structurally separated from one another rather than being close packed as in octahedral aquo ions [e.g., Al(H 2 O) 6 3+ ]. Thus, the bulk of the literature on rates of ligand substitution in aqueous ions may be a poor guide to the reactions of geochemical interest. To understand how separation of the reactive functional groups affects the rates of simple water exchange reactions, we synthesized two similar Rh(III) complexes, [Rh(phen) 2 H 2 O) 2 ] 3+ [1] and [Rh(phen) 2 (H 2 O)Cl] 2+ [2] (phen=1,10-phenanthroline) that differ in the number and proximity of bound waters. The complex [1] has two adjacent water molecules and [2] has a single water adjacent to a bound chloride ion. We employed Rh(III) as a trivalent metal rather than a more geochemically relevant metal like Fe(III) or Al(III) to slow the rate of reaction and dissociation of the molecules, which makes for simple measurement of the rates of isotopic substitution by mass spectrometry of the ions themselves as a function of time. We prepared isotopically unique versions of the molecules dissolved them in isotopically dissimilar solvent and measured the rates of exchange from the extents of 18 O and 16 O exchange at the bound waters. The rates differ enormously depending upon the protonation state of adjacent functional groups. Values of k298 when the molecules are nearly fully protonated are $k$$^{298}_{0}$ = 5·10 -8 s -1 for [1] and $k$$^{298}_{0}$ = 7.3·10 -9 for [2]. Enthalpy and entropy activation parameters (ΔH ‡ and ΔS ‡ ) were measured to be 121.1± 3 kJ mol -1 , and 22±10 J mol -1 K -1 , respectively for [1]. The corresponding parameters for the mono-aquo complex, [2], are 134.6± 3 kJ mol -1 and 50±5 J mol -1 K -1 . These compare well to other metals and nanometer-size clusters. Here, rates increase by many orders of magnitude upon deprotonation of one of the bound waters, but in a way that can be understood for geochemical systems at oxides. Key is the close proximity of a transferable proton that can convert the bound hydroxyl to a bound water and accelerate exchange for a bulk water. Thus, structural information about the location of bound waters relative to one another is a key piece of information to reconstruct rates of reactions at oxides surfaces.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Interpretation of production tests in geothermal wells with T2Well-EWASG

In the geothermal sector, being able to simulate production tests by combining surface and downhole measurements can be extremely useful, improving data interpretation and reducing the impact of unavailable field data. This is possible with T2Well, a coupled wellbore-reservoir simulator. In this study, we plugged the EWASG equation of state for high enthalpy geothermal reservoirs into T2Well and extended the function to analytically compute the heat exchange between wellbore and formation at the short times. Changes to the analytical heat exchange function were verified by comparison with wellbore-formation heat exchange numerically simulated. T2Well-EWASG was validated by reproducing the flowing pressure and temperature logs taken from literature, and by using the software for the interpretation of a short production test. Lastly, simulation results indicate that T2Well-EWASG can be effectively used to improve the interpretation of production tests performed in geothermal wells.

58 GEOSCIENCES↗

Implications of rootless geothermal models: Missing processes, parameter compensation, and imposter convection

Numerical models of geothermal systems commonly capture only the top of a reservoir. Deeper areas of the reservoir are simplified to a boundary at the base of the model domain. Commonly, the basal boundary is given either a heat source or a source of mass and enthalpy. Here we developed and present simple numerical experiments which demonstrate that these approaches do not produce the correct model behavior in comparison to a model that captures the entire convecting domain with a heat flux only. We describe a variety of incorrect types of model behavior that arise directly from the choice of boundary condition, independent of the specific parameterization of the model. Heat sources are sensitive to the thickness of the domain and parameters take unphysical values to compensate for the reduced height. The combined mass/heat boundary can produce temperatures that show similarities to circulating geothermal systems, but with incorrect fluid flow and a strong boundary layer focused at the base of the simulated clay cap. These errors likely cause parameters to adjust their values to compensate for the incorrect physics. We highlight these issues and show an example from a developed reservoir model. Initial calibrations to natural state temperature were unsuitable for history matching. The 3D model required parameter adjustments to achieve a more realistic production model. Appropriate mitigation measures should be considered to reduce parameter compensation and improve decision-support models.

15 GEOTHERMAL ENERGY↗