Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electrical distribution system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

Geophysical methods reveal the soil architecture and subsurface stratigraphic heterogeneities across land-lake interfaces along Lake Erie

Abstract Purpose The land-lake interface is a unique zone where terrestrial and aquatic ecosystems meet, forming part of the Earth’s most geochemically and biologically active zones. The unique characteristics of this interface are yet to be properly understood due to the inherently high spatiotemporal variability of subsurface properties, which are difficult to capture with the traditional soil sampling methods. Geophysical methods offer non-invasive techniques to capture variabilities in soil properties at a high resolution across various spatiotemporal scales. Methods We combined electromagnetic induction (EMI), electrical resistivity tomography (ERT), and ground penetrating radar (GPR) with data from soil cores and in situ sensors to investigate hydrostratigraphic heterogeneities across land-lake interfaces along the western basin of Lake Erie. Results EMI revealed high spatial heterogeneities in ECa distribution across the land-lake interfaces, with higher values in the wetland and transition zones compared to the upland zone. Soil ECa maps matched soil maps from a public database with the hydric soil units delineated as high conductivity zones (ECa > 40 mS/m). ERT and GPR showed vertical variation in soil properties with clear stratigraphic boundaries, and correlation of ERT profiles with lithologs from piezometers revealed the stratigraphic units of silt–clay and till sequence down to 3.5 m depth which are consistent with the surficial geology of the study area. Conclusions These results validate the use of multiple geophysical methods for extrapolating soil properties and mapping stratigraphic structures at land-lake interfaces, thereby providing the missing information required to improve the earth system model (ESM) of coastal interfaces.

54 ENVIRONMENTAL SCIENCES↗

California Price Response Potential Study

California's energy landscape is undergoing a significant transformation, driven by the increasing integration of renewable energy sources, the increased adoption of distributed energy resources, the electrification of end-use loads, and the growing need for grid efficiency. To address these challenges, recent revisions to the State’s Load Management Standards (LMS) require all of California’s large utilities and community choice aggregators (CCAs) to offer dynamic electricity pricing options to customers by 2027. Dynamic pricing, which involves varying electricity rates based on real-time supply and demand conditions, offers a promising solution for optimizing grid operations, reducing costs, and incentivizing efficient use of grid capacity. Effective implementation of dynamic pricing requires understanding the potential impacts on customer bills, system load, and the cost-effectiveness of automation technologies. This study aims to evaluate the load response of various end-use devices to hourly dynamic prices. The end-uses studied here are space cooling, space heating, water heating, crop irrigation, pool and spa pumps, and electric vehicle (EV) charging, all for both residential and commercial applications, except for crop irrigation. In 2030, these end uses are forecasted to account for 18% of annual electricity demand in the state, but 40% of demand in the peak net load hour. By modeling possible price-responsive load dispatch algorithms and assessing the resulting impacts on both individual bills and the overall grid, we seek to inform policymakers and utilities about the potential benefits and challenges associated with dynamic pricing, and considerations for the design of dynamic pricing tariffs. Additionally, we will explore the cost effectiveness of adopting automation technologies to enable devices to respond more effectively to real-time price signals. This study considers a range of price profiles, accounting for differences across utilities and customer classes, and presents scenarios for dynamic price design via variation in the percentage of total customer electric costs that are allocated dynamically (versus constituting a fixed portion of the hourly volumetric price). We present results focused primarily on 2030, forecasting electricity prices under both low and high-cost scenarios, to inform longer-term tariff design considerations. We design tariffs by starting with 2019 prices that were calculated according to CalFUSE guidance (CPUC, 2022) and that have been used in recent studies; these prices are all-in volumetric rates that vary by utility and are revenue-neutral to each customer class. They are developed by considering six electricity cost components that are allocated hourly based on system load indicators (gross and net load, and wholesale prices). These prices are forecasted to 2030 for low and high cost scenarios, considering recent trends in total electricity costs with and without years of substantial wildfire mitigation investments. These tariffs, which allocate all costs on an hourly basis, are considered our “Full” dynamic tariff design scenario, while two additional scenarios explore allocating a portion of costs as a flat volumetric charge: the “Medium” scenario allocates 50% of revenue dynamically (and keeps 50% flat), while the “Mild” scenario allocates 20% of revenue dynamically. The 20% dynamic allocation on the Mild scenario aims to represent a case where only the marginal operating costs of the grid are included in the dynamic price.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Designing for Zero Energy and Zero Carbon on a Multi-Building Scale Using URBANopt: Preprint

Groundbreaking efforts are necessary to mitigate contributors increasing impacts of climate change. In parallel to inventing pioneering clean energy technologies it is even more fundamental to rethink designing energy systems within a singular facility and collectively to function as a district. Facilities should not be continuously passive by just consuming; there is a need to shift to perform more dynamically. Designing for zero energy and zero carbon on a multi-building scale can uncover opportunities for building energy efficiency, decarbonization, demand flexibility, and resiliency that are not accessible at an individual building scale. This approach can be challenging without innovative tools to evaluate the multitude of possibilities. As an investigated result, we highlight the use of a campus-scale energy modeling platform - URBANopt™ - for the expansion of the National Renewable Energy Laboratory's (NREL's) South Table Mountain campus in Golden, Colorado. Programmatic growth included the design of three new all-electric, zero-energy, and zero-carbon, mixed used buildings (a combination of research laboratories and office space). This investigation is critical to NREL reaching net-zero emissions for its operational footprint, which will occur in phases over the next decade. Leveraging URBANopt's capabilities, we evaluate 1) high-performance building energy efficiency and decarbonization measures, 2) 4th generation district heating and cooling (4th GDHC) systems, 3) optimized onsite generation and energy storage assets that meet zero-energy and zero-carbon targets at minimum life-cycle costs, and 4) cost-optimal distributed energy technology mixes, dispatch strategies, and associated capacities that increase resiliency to grid outages. This work demonstrates the use and capabilities of URBANopt through a real-world case study on a multi-building scale.

community energy model↗

Application Guide for the Cyber-Resilient Design Framework for Hybrid Systems

As the energy landscape evolves, hybrid power plants—integrating multiple renewable energy sources (e.g., solar, wind, and battery storage) with the bulk power electric system—play a crucial role in meeting growing energy demands. However, with a hybrid power plant’s increased number of components, complex network connectivity and digitization of controls, these systems face growing cybersecurity risks. To help mitigate these risks, Idaho National Laboratory (INL) presents this application guide specifically designed for operators and systems engineers to evaluate the cybersecurity resilience of their hybrid power plant’s design.

14 SOLAR ENERGY↗

Intel® DOE Grid Security Enhancement Security in Power System Edge. Final Technical Report

Intel® and its partners, Schneider Electric and LiveData Utilities, were tasked by Department of Energy to explore solutions in two areas of grid security. One, secure the existing communication network and the legacy devices with minimal disruption to the infrastructure, and second, to develop capabilities in semiconductor chips such that they come with built-in security to order to provide secure communication and protection from cyberattacks with minimal effort from operation technology (OT) application developers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Grid Resiliency with a 100% Renewable Microgrid

San Diego Gas & Electric Company (SDG&E) installed America’s first and largest utility-scale microgrid in Borrego Springs in 2013. The first generation Borrego Springs Microgrid utilized diesel generators to form and stabilize the microgrid island, with support from grid-scale batteries and local solar photovoltaic (PV) generation. In this project, SDG&E in partnership with National Renewable Energy Laboratory (NREL) demonstrated through modeling, simulation and utility field testing that blackstart and islanding of the microgrid can be led with 100% renewable, inverter based resources (IBRs), to help reduce community reliance on conventional generation resources. Through equipment upgrades, grid-forming island leader capability was transitioned to a battery IBR instead of the Borrego Springs Microgrid diesel generators. A new microgrid controller was integrated to the microgrid and programmed to control and manage multiple energy storage systems. Synchrophasor and other power quality data verified autonomous, high-speed response of the IBRs through blackstart, islanding, and load step testing. Results of project field evaluations provide distribution systems operators (DSO) with increased confidence that renewable, IBR can replace traditional generators to blackstart and island microgrids and rapidly establish stable island frequency with rapid changes in peak power demand. Importantly, the project validated the integration feasibility of a distributed energy resource management system (DERMS) controller that manages multiple grid-forming and grid-following IBRs, establishing a standard design interface to reduce the complexity of integrating new DERs in the future and supporting replication by the industry. As a result of learnings in this project, SDG&E has implemented the microgrid controller strategy at multiple other microgrid sites, thereby validating the replicability of the solution. Hardware-in-the-loop (HIL) simulations including power and controller HIL hardware — along with electromagnetic transient (EMT) simulations of Borrego Springs Microgrid —informed adjustments to inverter parameters and were important to characterize the performance of the IBRs in relevant operating conditions before deployment. The EMT and HIL simulations of islanding the entire community are important contributions in providing confidence in IBR performance prior to future islanding of the community in the field. High-fidelity EMT and/or HIL simulation of IBRs can de-risk field operations, and its relevance and importance as a tool is increasing as distribution grids and microgrids become more complex and dynamic with an increasing proportion of renewable generation, distributed energy storage, and two-way power and energy flows.

24 POWER TRANSMISSION AND DISTRIBUTION↗

3D oxygen vacancy distribution and defect-property relations in an oxide heterostructure

Oxide heterostructures exhibit a vast variety of unique physical properties. Examples are unconventional superconductivity in layered nickelates and topological polar order in (PbTiO 3 ) n /(SrTiO 3 ) n superlattices. Although it is clear that variations in oxygen content are crucial for the electronic correlation phenomena in oxides, it remains a major challenge to quantify their impact. Here, we measure the chemical composition in multiferroic (LuFeO 3 ) 9 /(LuFe 2 O 4 ) 1 superlattices, mapping correlations between the distribution of oxygen vacancies and the electric and magnetic properties. Using atom probe tomography, we observe oxygen vacancies arranging in a layered three-dimensional structure with a local density on the order of 10 14 cm -2 , congruent with the formula-unit-thick ferrimagnetic LuFe 2 O 4 layers. The vacancy order is promoted by the locally reduced formation energy and plays a key role in stabilizing the ferroelectric domains and ferrimagnetism in the LuFeO 3 and LuFe 2 O 4 layers, respectively. The results demonstrate pronounced interactions between oxygen vacancies and the multiferroic order in this system and establish an approach for quantifying the oxygen defects with atomic-scale precision in 3D, giving new opportunities for deterministic defect-enabled property control in oxide heterostructures.

36 MATERIALS SCIENCE↗

Making Wireless Power Matter (CRADA Final Report)

The Resonant Link project team investigated the integration of their novel, self-resonant magnetic structure for electromagnetic coils into inductive wireless power transfer systems. Relative to conventional wireless power coils, their multi-layer self-resonant structure (the “MSRS”) reduces losses by up to 6x and lowers to BOM cost by up to 10x. These power-dense, cost-effective coils are a promising path towards the first value-add wireless power systems in a variety of applications, from phones to medical devices to kitchen appliances to mobile robots to electric vehicles. The researchers explored development of the power electronics for wireless power transfer systems using the multi-layer self-resonant structure (MSRS) concept that efficiently transmits power over air gaps for in-home applications, including through-wall power transfer, appliances built around the Ki and Qi standards, and other potential use cases This project specifically focused on the power electronics design, development, and testing for these applications. Resonant Link’s proprietary wireless power technology holds the promise of matching the performance of wired chargers in size and efficiency, especially when operated from a DC distribution grid.

42 ENGINEERING↗

Methodology to Implement a Microgrid in a University Campus

This paper presents the method we followed to design a microgrid at a university campus based on available resources. Due to introduction of renewable resources to produce energy, a methodology that allows design a microgrid in a university campus is very useful. Hence, we present a series of steps that must be carried out to estimate the resource to be used, the installation, area needed, and the capacity of the systems needed are also described. In addition, the models of the distributed resources that constitutes the microgrid are presented and explained. To validate the proposed methodology, simulations were performed using Opal-RT-LAb. As a test scenario we selected the Mayagüez campus of the University of Puerto Rico where we conducted analysis of the available resource and capacity of the systems is needed to satisfy demand of critical loads, considering a predetermined number of days of austerity. Our study results in determination of dimensions, cost and effectiveness of the microgrid. Simulations results also show that the proposed microgrid satisfy demand with the same reliability, or better, than the traditional electrical network. Additionally, the best options for this purpose are photovoltaic, batteries, and combined heat and power, if the technological advances and availability of resources to the date for Puerto Rico are considered.

36 MATERIALS SCIENCE↗

All Hazards Approach to Grid Modernization

Resilience hazards for electric power systems are on the rise, exacerbated by both a rise in extreme weather events and manmade physical and cyber attacks. At the same time, grid modernization challenges plague the United States, covering everything from increased electrification and ambitious renewable energy targets to aging infrastructure and regulation that lags behind today’s challenges. This talk will cover an all-hazards risk based approach that addresses both rising resilience and grid modernization challenges. Examples of this approach taken for national laboratory research projects will be discussed, including a deep dive into a project that addressed black start, resynchronization, distributed control, and cybersecurity challenges for an operational microgrid up to sub-transmission voltages. As takeaways from this project are translated from demonstration scale to real-world exercises, key lessons are noted on the translation from research into practice and how this can inform risk-based research moving forward

17 WIND ENERGY↗

Valuing Resilience for Microgrids: Challenges, Innovative Approaches, and State Needs

The United States depends on the delivery of reliable, affordable, clean, and safe electricity. Electric utilities invest billions of dollars each year in generation, transmission, and distribution assets to meet this need. However, experiences with recent natural disasters of increasing frequency and duration demonstrate the shortcomings of this approach in the face of modern threats. Further, as customers rely on electricity for a broader range of important needs, such as transportation, as well as critical life-saving services and mission critical facilities such as water treatment, medical care, shelters, telecommunications, and more, the need to minimize the likelihood and impacts of outages grows. Against this backdrop, resilience has emerged as a key consideration to guide electricity spending, whether from utilities, customers, or taxpayers. Although reliability has been defined and measured for decades with broadly accepted metrics that measure how many customers lose power and at what frequency and duration, resilience considers the electricity system’s response to a disruption and its subsequent impacts on customers. Developing tools and methods to accurately assess the costs and benefits of resilience investments is a critical step toward the goal of mitigating the impacts of outages on customers and society. Today, electric system resilience is largely treated as an externality due to challenges estimating the costs of long-duration outages, impacts of outages on society, and increasing reliance on electricity for a growing set of interdependent services. These interdependencies include the water, wastewater, telecommunications, natural gas, and health sectors. Without knowing how much a given resilience investment will benefit customers or society more broadly, investors, policymakers, and regulators are less likely to make or approve such investments, and less able to prioritize those investments. State Energy Offices and public utility commissions (PUCs) lead the development of state-level energy policy and utility regulation, respectively, and each has interests in encouraging appropriate public and private investments in resilience. To this end, the National Association of State Energy Officials (NASEO) and National Association of Regulatory Utility Commissioners (NARUC), with the support of the U.S. Department of Energy (DOE) Office of Electricity (OE), formed a joint Microgrids State Working Group to explore the costs and benefits of microgrids, barriers to broader deployment of microgrids to meet resilience and other objectives, and policy and regulatory strategies to optimize investments in resilience, including but not limited to microgrids. Although no universally accepted valuation tool for resilience exists, National Laboratories, utilities, researchers, and state and federal agencies have collaborated to develop, apply, and improve a number of approaches to quantify resilience, several of which are still in progress at the time this report is published. This report seeks to share these important advances by discussing current definitions of resilience (Section 1), how microgrids are defined and used to meet resilience objectives (Section 2), new approaches to valuing resilience (Section 3), steps State Energy Offices and PUCs have taken to further resilience valuation efforts (Section 4), and finally, considerations and suggested next steps for State Energy Offices and PUCs (Section 5). Relevant examples of specific microgrid projects and resilience valuation efforts are included throughout the report. While this report is written specifically for NASEO and NARUC members, it may be useful for utilities, local governments, and individual customers interested in improving the way public and private dollars are spent to achieve resilience outcomes.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Strategies for Continuous Balancing in Future Power Systems with High Wind and Solar Shares

The use of wind power has grown strongly in recent years and is expected to continue to increase in the coming decades. Solar power is also expected to increase significantly. In a power system, a continuous balance is maintained between total production and demand. This balancing is currently mainly managed with conventional power plants, but with larger amounts of wind and solar power, other sources will also be needed. Interesting possibilities include continuous control of wind and solar power, battery storage, electric vehicles, hydrogen production, and other demand resources with flexibility potential. The aim of this article is to describe and compare the different challenges and future possibilities in six systems concerning how to keep a continuous balance in the future with significantly larger amounts of variable renewable power production. A realistic understanding of how these systems plan to handle continuous balancing is central to effectively develop a carbon-dioxide-free electricity system of the future. The systems included in the overview are the Nordic synchronous area, the island of Ireland, the Iberian Peninsula, Texas (ERCOT), the central European system, and Great Britain.

14 SOLAR ENERGY↗

Technoeconomic Opportunity Analysis for Local Power Generation in Falls City, Nebraska

Falls City is a small community in Nebraska interested in understanding how energy from local energy systems could support the community's economic development planning. To address the current community needs and address the future energy demand technical assistance conducted through the Communities Local Energy Action Program (Communities LEAP) assessed the technical and economic opportunities of adding energy technologies to Falls City's municipally owned and operated electric utility system. The modeling performed considered the technical and economic feasibility of technologies using the System Advisor Model (SAM). The modeling explored three technology configurations using multiple years of historical weather and wholesale cost data (2015-2022 & a typical meteorological year), and two different wholesale escalation rates (0.3% and 2.5%). Wholesale energy prices were based on the Southwest Power Pool's (SPP) real-time energy market and the annual escalation rates of these rates based on historical SPP wholesale and national retail electricity price trends. Results from the modeling showed that at current CAPEX costs and SPP wholesale electricity costs no technology combination averaged across the scenarios run provide a positive net present value (NPV). External financial support, changes in market conditions, and additional revenue streams would help create more economically favorable projects. As conditions change re-evaluation may be necessary.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Emergency Diesel Generator Reliability and Installation Energy Security

The U.S. Department of Defense’s (DoD’s) fixed installations - or military bases - are a critical element of national security. Military bases support the maintenance and deployment of weapons systems, training and mobilization of combat forces, and provide direct support to combat operations. Fixed installations do not operate without energy and they rely largely on electricity to support critical missions and functions. Installations are dependent on a commercial grid that is vulnerable to disruption due to severe weather, physical attacks, and cyberattacks. This report looks at the impact on the highest priority critical loads.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Thermal and electric multidomain dynamic model for integration of power grid distribution with behind-the-meter devices

As renewable energy sources like solar and wind power become more integrated into the grid, coordinated control of behind-the-meter devices is crucial for enhancing grid flexibility and reliability and for meeting cost targets, with standardized models being developed to support this transition. The increasing flexibility and uncertainty of integrated renewable energy grids, along with interactions between various subsystems, make traditional steady-state modeling insufficient to capture transient and dynamic behaviors. Current models (e.g., composite load and battery equivalent models) focus on thermodynamic or electrical characteristics but overlook critical electromechanical interactions. This limits the ability to share performance information for grid services and hampers fast dynamic simulations. In addition, motor stalling is usually triggered by a fault event and attributed to the characteristics of the mechanical torque of the motor, resulting in absorption of a large amount of reactive power during the stalling period. Further, this significant withdrawal of reactive power will deteriorate the dynamic voltage stability of power grids and cause delayed voltage recovery. Therefore, an in-depth modeling of the thermodynamics or mechanical torque is essential to study the impacts of the realistic torque characteristics of those behind-the-meter devices on power system voltage stability. This study developed a dynamic multidomain model for building HVAC systems, such as air-source heat pumps, to simulate their thermal and electrical responses to grid transients. The model can accurately predict power metrics with a mean absolute percentage error of 10%, by validating against with power system computer-aided design performance data. Case studies demonstrate the model capability of capturing the transient response to sudden voltage changes, rapid load fluctuations, and system shutdowns respectively. During a sudden voltage drop (30% for 0.1s), a fully loaded heat pump’s motor speed dropped, continued declining, and shut down after 3.6s, with severe power oscillations and a torque spike. A partially loaded unit experienced temporary oscillations but stabilized. Under higher building loads, compressor speed increased from 64% to 100%, with power and torque rising before stabilizing. In safety-triggered shutdowns, power decreased after minor fluctuations, and torque briefly spiked before dropping to zero.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Multi-Fidelity Stochastic Economic Dispatch for Operating Low Carbon Power Grids

Grid operators can address the inherently stochastic nature of renewables by solving a two-stage stochastic programming model that minimizes the cost of dispatch decisions while accounting for the complex grid dynamics. It is common to use a sample average approximation to estimate the expectation of the second stage costs in this model. However, the large sample count needed for numerical accuracy makes effective modeling large-scale electric grids computationally intractable. We introduce a control variate multi-fidelity estimator for the second-stage recourse that enables high quality dispatch decisions in real-time with a reduced computational burden. We obtain a hierarchy of model fidelities by linearizing the AC power flow system representation to DC power flow, and by relaxing transmission and voltage network constraints. We evaluate the performance of our proposed method on a synthetic grid with 73 buses against a deterministic baseline with persistence forecast and a high-fidelity reference. Our analysis shows a computational speed-up of 7.62x with a minimal loss in accuracy. The multi-fidelity method is well suited to fidelity combinations that use a simplified network topology in their lower fidelity model and is an attractive option for applications where accurate grid modeling needed on a limited computational budget.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Microscopic ejecta measurements from hypervelocity impacts on aluminum and powdered regolith targets

Meteoroids and space debris pose a two-fold threat to spacecraft due to the risk of both mechanical damage from the impact and electrical damage from the impact-generated plasma, which produces electromagnetic emissions. Analysis of impact products, however, has the potential to provide useful information about planetary rings and small solar system bodies, such as asteroids and comets. Understanding the plasma dynamics and radiation mechanism is essential to addressing the impact threat and extracting science data from impacts. Charge attachment to condensed-phase debris may lead to a dusty plasma under certain conditions, so interpreting hypervelocity impacts requires knowledge of both the nature of the plasma and of the ejecta. We address the latter with measurements of the microscopic ejecta distribution produced by light gas gun impacts on solid aluminum and powdered regolith simulant targets. We examine both the size and shape of the ejecta using thin-film witness plates and find that the size distributions of microscopic ejecta follow power laws. Observations from the powdered regolith simulant match well with disruption experiments of solid basalt, while measurements from the aluminum impacts diverge from extrapolations based on studies of macroscopic debris. Analysis of the ejecta shape shows a transition from smooth to irregularly shaped ejecta at the material grain size, and the shape of debris may provide insight on the phase of the ejected material. Finally, based on our results, we predict a significant number of secondary impacts on plasma sensors due to ejecta, even at considerable distance from the target, supporting the hypothesis that charged dust affects plasma measurements in the ejecta curtain.

42 ENGINEERING↗

Grid-Forming and Grid-Following Inverter Comparison of Droop Response

With the increase in penetration of inverter-based resources (IBRs) in the electrical power system, the ability of these devices to provide grid support to the system has become a necessity. With standards previously developed for the interconnection requirements of grid-following inverters (GFLI) (most commonly photovoltaic inverters), it has been well documented how these inverters “should” respond to changes in voltage and frequency. However, with other IBRs such as grid-forming inverters (GFMIs) (used for energy storage systems, standalone systems, and as uninterruptable power supplies) these requirements are either: not yet documented, or require a more in deep analysis. With the increased interest in microgrids, GFMIs that can be paralleled onto a distribution system have become desired. With the proper control schemes, a GFMI can help maintain grid stability through fast response compared to rotating machines. This paper will present an experimental comparison of commercially available GFMI and GFLI ' responses to voltage and frequency deviation, as well as the GFMI operating as a standalone system and subjected to various changes in loads.

Grid Support, Inverter, Droop Control, Volt-VAR, F↗