Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “efficiencies”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

Highly efficient small molecule multi-junction organic photovoltaic cells

A highly efficient multi junction photovoltaic device, such as a two, three, or four junction device, is disclosed. The multi-junction device may include a first subcell comprising a first photoactive region and a second subcell comprising a second photoactive region. The first and second photoactive regions are designed to minimize spectral overlap and maximize photocurrent across a broad absorption spectra, such as wavelengths ranging from 400 nm to 900 nm. The device may further include an inter-connecting layer, disposed between the first subcell and the second subcell, that is at least substantially transparent. By introducing a transparent interconnecting layer, a dual element (tandem) cell achieves a power conversion efficiency of 10.0±0.5%. By adding an additional (3rd) sub-cell that absorbs at the second order optical interference maximum within the stack. The triple junction cell significantly improves the quantum efficiency at shorter wavelengths, achieving a power conversion efficiency of 11.1±0.5%. Adding additional sub-cells has been shown to increase power conversion efficiency above 12%.

Che, Xiaozhou↗

Record Efficiency InGaAs Thermophotovoltaic Cells For Energy Storage Applications

Utility-scale energy storage is a significant technical challenge and a key barrier to widespread adoption of renewable energy. An efficient, modular, and scalable solution can be achieved by storing energy in the form of high-temperature heat and then extracting energy, on demand, using thermophotovoltaic (TPV) cells to convert the heat back to electricity. The ideal thermal emitter temperature is determined by balancing the desire for higher power densities, high-temperature compliant materials, and efficient, cost-effective thermophotovoltaic cells, among other considerations. 0.74-eV InGaAs lattice-matched to InP is a good choice for a cell absorber, and here we describe our development of InGaAs TPV cells with efficiencies of 38.8% from an ~1850 degrees celsius source temperature. This is the highest efficiency yet measured and reported for a single-junction TPV device. This efficiency was achieved by carefully quantifying and then reducing the parasitic absorption in the semiconductor layers, and by significantly reducing the series resistance to minimize the power loss.

ENERGY STORAGE,ENGINEERING,SOLAR ENERGY↗

Impact of Nozzle Condition on Powder Catchment Efficiency for Coaxial Powder Direct Energy Deposition

Blown powder directed energy deposition is well-designed for fine resolution additive manufacturing processing. Coaxial powder deposition heads use an outer layer of shielding gas directed by an outer nozzle to prevent oxidation occurring during the powder melting process. Powder blown feedstock catchment efficiency can be as low as 50-80% whereas wire deposition systems are closer to 98% efficient. The present study evaluates the impact of directed energy deposition nozzle condition on catchment efficiency. Changes in the overall outer shielding gas nozzle length has been found to increase material usage efficiency by 10% through convergence of the powder flow. The results of this experiment show that for coaxial powder deposition head design, if the standoff distance can safely be decreased, powder catchment efficiency can be increased as the outer shielding gas nozzle is increased in length, or the standoff distance is decreased.

Heinrich, Lauren↗

Impact of Nozzle Condition on Powder Catchment Efficiency for Coaxial Powder Direct Energy Deposition

Blown powder directed energy deposition is well-designed for fine resolution additive manufacturing processing. Coaxial powder deposition heads use an outer layer of shielding gas directed by an outer nozzle to prevent oxidation occurring during the powder melting process. Powder blown feedstock catchment efficiency can be as low as 50-80% whereas wire deposition systems are closer to 98% efficient. The present study evaluates the impact of directed energy deposition nozzle condition on catchment efficiency. Changes in the overall outer shielding gas nozzle length has been found to increase material usage efficiency by 10% through convergence of the powder flow. The results of this experiment show that for coaxial powder deposition head design, if the standoff distance can safely be decreased, powder catchment efficiency can be increased as the outer shielding gas nozzle is increased in length, or the standoff distance is decreased.

Heinrich, Lauren↗

Maximizing Operational Efficiencies in Waste Management on the Hanford Plateau Remediation Contract in a Down-turned Market - 13484

Recent changes in DOE priorities and funding have pressed DOE and its contractors to look for innovative methods to sustain critical operations at sites across the Complex. At the Hanford Site, DOE Richland Operations and its prime contractor, CH2M Hill Plateau Remediation Company (CHPRC), have completed in-depth assessments of the Plateau Remediation Contract (PRC) operations that compared available funding to mission and operational objectives in an effort to maintain requisite safety and compliance margins while realizing cost savings that meet funding profiles. These assessments included confirmation of current baseline activities, identification of potential efficiencies, barriers to implementation, and potential increased risks associated with implementation. Six operating PRC waste management facilities were evaluated against three possible end-states: complete facility closure, maintaining base operations, and performing minimum safe surveillance and maintenance activities. The costs to completely close evaluated facilities were determined to be prohibitively high and this end-state was quickly dropped from consideration. A summary of the analysis of remaining options by facility, efficiencies identified, impact to risk profiles, and expected cost savings is provided in Table I. The expected cost savings are a result of: - right-sizing and cross-training work crews to address maintenance activities across facilities; - combining and sequencing 'like-moded' operational processes; - cross-cutting emergency planning and preparedness staffing; - resource redistribution and optimization; - reducing areas requiring routine surveillance and inspection. For the efficiencies identified, there are corresponding increases in risk, including a loss of breadth and depth of available resources; lengthened response time to emergent issues; inability to invest in opportunities for improvement (OFIs); potential single-point failures or non-compliancies due to resource scarcity; limited cross-training capability; and reduced capability to respond to changes in DOE priorities. Finally, there are many challenges to achieving these cost savings. With a workforce nearing retirement effective succession planning becomes critical to success and requires establishing a balance between the cost of hiring and training and cost-saving activities. With six active waste management facilities spread across nearly 15 square miles, scheduling and deploying cross-trained surveillance and maintenance teams is a logistical challenge, particularly as the loss of funding has not diminished emphasis by regulatory agencies placed on the safe and compliant performance of DOE and its contractors. As reflected in Table I, efficiencies are currently being implemented on the Hanford Plateau Remediation Contract (PRC) that deliver cost savings that align with the current site budget while maintaining critical capabilities. It is currently estimated that these efficiencies will result in a cost savings of approximately $9 million for FY13 in base and minimum safe operations on the PRC - a cost reduction of more than 13 percent over FY12 and nearly 30 percent over FY09 levels. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Efforts to Improve Efficiency of Extraction Well Operation at the Fernald Preserve, Harrison, Ohio - 16177

The Fernald Preserve, a former uranium processing facility that produced high-purity uranium metal products during the Cold War, is located in southwest Ohio. The facility became a US Department of Energy Office of Legacy Management (LM) site in November 2006, following completion of the Comprehensive Environmental Response, Compensation, and Liability Act environmental remediation and site restoration (with the exception of groundwater). When the site was turned over to LM, approximately 76.5 ha of the Great Miami Aquifer remained contaminated with uranium above the final remediation level of 30 μg/L. Here, uranium contamination is being removed from groundwater in the Great Miami Aquifer through a pump-and-treat operation, which is predicted to continue until 2033. Twenty extraction wells pump about 30 million liters per day. Operation of the system is impacted by iron in the groundwater that promotes iron fouling of the well pumps, motors, and screens. The design of the well field evolved over 21 years and reflected a conservative system that could respond to a wide range of pumping conditions. For instance, some of the extraction wells were sized with pumps and motors that would allow the well to pump up to 1890 L/min (500 gpm) if warranted. The added flexibility, though, came at the cost of operational efficiency. We describe the efforts that have been taken by LM since the Fernald site was transferred to LM to mitigate the operational impacts from the iron fouling aquifer conditions and improve the efficiency of the well-field operation. Variable-frequency drives were installed at six wells to replace flow control valves. Several wells with oversized pumps and motors were changed from 24-hour per day operation to 8-hour per day operation to allow the pumps to operate closer to their design flow rates. Pumps and motors were 'right-sized' at many wells to improve pumping efficiency. The process used to rehabilitate (or clean) well screens was improved, and a process was developed to clean pumps without having to pull them from the well. To reduce pressure drops, improvements were also made to the configuration of the discharge piping. A new control system was installed for each well to allow local control and local tracking of energy used. The amount of energy used daily compared to number of gallons pumped provides a method to assess pump performance and determine when action is necessary to restore well pump efficiency. Additionally, the metrics being employed to help quantify well-field efficiency improvements are described, and the benefits achieved by proactively managing the pump-and-treat operation are presented. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Efficient Mesofluidic Separation of Large Particles in nuclear slurries - 20408

Efficient and effective particle separation is essential to cleanup of many nuclear wastes. For example, particle separation may be used to accelerate settle-decant bottlenecks that limit the throughput necessary to achieve the U.S. Department of Energy waste cleanup mission in a timely manner. Particle separation may be used to protect downstream processing equipment from pulses of solids that may be encountered near (within a few feet of) liquid-solid interfaces during waste transfer operations, thereby preventing work stoppages. Effective particle separation may permit efficient sludge washing. These are only a few of the ways in which particle separation is important. Yet, efficient and effective particle separation in nuclear processing environments remains challenging. For example, settle-decant operations permit larger and heavier particles to settle, leaving smaller, lighter particles suspended. However, settle-decant operations are slow, convection currents may resuspend solids, hindered settling of multicomponent slurries remains incompletely understood, and predictive models for settling in graduated cylinders fail to match limited observations of settling in large waste tanks. Additionally, pumping operations can cause turbulent resuspension of particles when the pump intake is close to the settled solids layer. Filtration techniques that use membranes or partially permeable barriers retain larger particles, permitting smaller particles to permeate. However, filters, including dead-end filtration, are prone to clogging and caking, operate at elevated pressures due to minimal void volume, and increase in pressure during operations, which require more control systems. Therefore, the need for high throughput particle separation techniques that operate with modest pressure drops persists. A novel mesofluidic separator presents the opportunity to effectively and efficiently accelerate the waste cleanup mission. The separator separates large particles from process streams across a broad range of particle sizes and has no moving parts or media to replace, regenerate, or clean. This separator design has an unusually large void volume, permitting operation at much higher flow rates (and lower pressures) than traditional filtration (e.g., dead-end filtration). Industrial-scale flow rates have been demonstrated. In performance testing, mesofluidic separators operate at might flow rates (>90 gpm (0.0006 m{sup 3}/s) in piping 3 inches (0.08 m) in diameter; Re>10{sup 5}), with modest pressure drop (∼25 psi (170 KPa) in testing). In complex, aggregating waste simulants, the separator loses <25% of flow projected over months without back pulsing or chemical cleaning. Mesofluidic separation presents infrastructure advantages, reduces risk, and provides mission impact. Infrastructure advantages include implementation within existing transfer systems, plug and play without facility modifications to safety systems, and operation at low pressures. The separator is flexible in location, may be positioned within or outside of waste tanks, and may replace or augment dead-end and cross-flow filters. Mesofluidic separation reduces risk by minimizing waste (no media to replace or regenerate and no cleaning chemicals to handle and dispose) and by minimizing filter change-out consistent with as low as reasonably achievable (ALARA) exposure to workers. The potential mission impact of these separators is substantial. The separator has potential to support, simplify, and accelerate in-farm transfers and waste feed delivery. Furthermore, the separator can free up settling and holding tanks in the Direct Feed Low-Activity Waste (DFLAW) mission by reducing or eliminating post-transfer settling and wait times with the potential to free up 1 Mgal (4000 m{sup 3}) of double-shell tank space. This paper quantitatively compares mesofluidic separation to dead-end filtration, discusses scale-up results, and considers the separator's potential to efficiently and effectively reduce the long-term environmental ability of particulate-rich nuclear wastes. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Preliminary Development of a Drift-Flux Model Based Pin-Resolved Core Thermal-Hydraulic Code for Dedicated Use in Efficient High-Fidelity Neutronics Coupled Calculations

As the high-fidelity multiphysics coupled core calculation becomes more practical with the advent of high-performance computing technology, efficient coupling of a neutronics code with a thermal-hydraulic (T/H) code at the pin level poses a new challenge. The COBRA-TF (CTF) code which is one of the well-known subchannel analysis codes based on the two-fluid, three-field model was coupled with many neutron transport codes such as MPACT, TORTTD, and nTRACER due to the easiness of coupling by its well-established coupling interface. Nevertheless, the calculation efficiency of such coupled codes is not satisfactory because of the heavy computational burden of CTF. The MATRA subchannel analysis code of KAERI which is based on the homogeneous equilibrium model (HEM) was coupled with neutronics codes as well. The choice of the HEM and the marching scheme in MATRA reduces the computational burden significantly. However, the applicability of the HEM for the two-phase flow conditions is limited to normal operating conditions of pressurized water reactors (PWRs) and therefore a better model which would allow wider applicability than HEM is necessary in order to deal with the core states involving nontrivial voiding. The drift-flux model (DFM) which uses 5 equations for two-fluid analyses by adopting the mixture velocity instead of two phasic velocities can be a good compromise between the two-fluid model and the HEM. With the DFM, the computational cost can be reduced and moreover the modeling of the interfacial area constitutive relations can be avoided. The phase separation for the mixture velocity can be incorporated by using the drift-flux parameters, C0 and Vgj, which can be obtained by using empirical formulas. Several subchannel codes such as WOSUB and ASSERT were developed based on the DFM. It was also adopted in some system analysis codes such as RETRAN3D. In the work here, the development of a DFM based pin-resolved T/H analysis code, ESCOT (Efficient Simulator of Core Thermal-hydraulics), is introduced for the use in efficient coupled calculations with a high-fidelity neutronics code. The field equations and the numerical methods are briefly described. Then the efficiency tests of various linear system solvers including the Krylov subspace methods (KSMs) are presented. A test problem is solved by ESCOT, MATRA and CTF for performance comparison and validation. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

GeoLoRA: Geometric integration for parameter efficient fine-tuning

Low-Rank Adaptation (LoRA) has become a widely used method for parameter-efficient fine-tuning of large-scale, pre-trained neural networks. However, LoRA and its extensions face several challenges, including the need for rank adaptivity, robustness, and computational efficiency during the fine-tuning process. We introduce GeoLoRA, a novel approach that addresses these limitations by leveraging dynamical low-rank approximation theory. GeoLoRA requires only a single backpropagation pass over the small-rank adapters, significantly reducing computational cost as compared to similar dynamical low-rank training methods and making it faster than popular baselines such as AdaLoRA. This allows GeoLoRA to efficiently adapt the allocated parameter budget across the model, achieving smaller low-rank adapters compared to heuristic methods like AdaLoRA and LoRA, while maintaining critical convergence, descent, and error-bound theoretical guarantees. The resulting method is not only more efficient but also more robust to varying hyperparameter settings. We demonstrate the effectiveness of GeoLoRA on several state-of-the-art benchmarks, showing that it outperforms existing methods in both accuracy and computational efficiency.

Schotthoefer, Steffen [ORNL] (ORCID:00000002156965↗

Systems Innovation: Modernization & Efficiencies for ESH&Q Reviews

Environmental compliance reviews at INL have traditionally been managed through fragmented systems, relying on multiple spreadsheets and manual processes. This inefficiency led to time-consuming status updates and redundant tasks, such as manually sending reminder emails and transferring data from Excel to the Environmental Review Process (ERP). Initial attempts to streamline these processes using Power Automate and Excel revealed significant limitations, necessitating a more comprehensive solution. To address these immediate inefficiencies, automated workflows were developed using Power Automate. These workflows were designed to send scheduled status update reminders and capture responses through standardized forms, with submitted data flowing directly into centralized Excel trackers. This automation reduced the administrative burden, improved data accuracy, and enabled faster, more consistent reporting. Specifically, email automation achieved a 65% efficiency gain, while data integration saw a 48% improvement, resulting in 91% of project statuses being updated within two months. Despite the improvements brought by Power Automate, the fragmented nature of the review processes persisted. To further enhance efficiency and accuracy, the Integrated Review Tool (IRT) was developed. The IRT aims to centralize review initiation and connect team systems, creating an interconnected data infrastructure that preserves team autonomy while enhancing overall efficiency. This tool automates email reminders, centralizes reviews, and streamlines data integration, significantly improving the accuracy and efficiency of environmental compliance reviews. The design and development of the IRT involved advanced systems methodology, process mapping, project management, and collaboration with subject matter experts. The minimum viable product design is 100% complete, and system development is currently underway, with expected outcomes including a centralized entry point for all ESH&Q reviews, automated routing, real-time tracking and analytics, AI integration, and a user-friendly interface. This project demonstrates the potential of leveraging automation and integrated systems to enhance efficiency, accuracy, and decision-making in environmental reporting and compliance processes at INL.

99 - GENERAL AND MISCELLANEOUS↗

A Software Package Using a Mesh-grid Method for Simulating HPGe Detector Efficiencies

Traditional ways of determining the absolute full-energy peak efficiencies of high-purity germanium (HPGe) detectors are often time consuming, cost prohibitive, or not feasible. A software package, KMESS (Kevin’s Mesh Efficiency Simulator Software), was developed to assist in predicting these efficiencies. It uses a semiempirical mesh-grid method and works for arbitrary source shapes and counting geometries. The model assumes that any gamma-ray source shape can be treated as a large enough collection of point sources. The code is readily adaptable, has a web-based graphical front-end, and could easily be coupled to a 3D scanner. As will be shown, this software can estimate absolute full-energy peak efficiencies with good accuracy in reasonable computation times. It has applications to the field of gamma-ray spectroscopy because it is a quick and accurate way to assist in performing quantitative analyses using HPGe detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Persistent and transient cost efficiency—an application to the Swiss hydropower sector

Electricity prices on the European market have decreased significantly over the past few years, resulting in a deterioration of Swiss hydropower firms’ competitiveness and profitability. One option to improve the sector’s competitiveness is to increase cost efficiency. The goal of this study is to quantify the level of persistent and transient cost efficiency of individual firms by applying the generalized true random effects (GTRE) model introduced by Colombi et al. (Journal of Productivity Analysis 42(2): 123–136, 2014) and Filippini and Greene (Journal of Productivity Analysis 45(2): 187–196, 2016). Applying this newly developed GTRE model to a total cost function, the level of cost efficiency of 65 Swiss hydropower firms is analyzed for the period between 2000 and 2013. A true random effects specification is estimated as a benchmark for the transient level of cost efficiency. The results show the presence of both transient as well as persistent cost inefficiencies. The GTREM predicts the aggregate level of cost inefficiency to amount to 21.8% (8.0% transient, 13.8% persistent) on average between 2000 and 2013. These two components differ in interpretation and implication. From an individual firm’s perspective, the two types of cost inefficiencies might require a firm’s management to respond with different improvement strategies. The existing level of persistent inefficiency could prevent the hydropower firms from adjusting their production processes to new market environments. From a regulatory point of view, the results of this study could be used in the scope and determination of the amount of financial support given to struggling firms.

13 HYDRO ENERGY↗

Linking groundwater variability to ecosystem carbon and water use efficiencies across India

Carbon use efficiency (CUE) and water use efficiency (WUE) are important indicators of ecosystem health, reflecting the balance between carbon uptake and allocation, and the relationship between carbon assimilation and water loss. Although India shows large spatiotemporal variation in water table depth (WTD), and increasing groundwater stress, the influence of WTD on ecosystem functioning remains underexplored. This study uses satellite-based, modeled, and in-situ datasets to (1) quantify variations in CUE and WUE under shallow (SWTD) and deep (DWTD) WTD conditions across six homogeneous meteorological regions (HMRs), (2) evaluate temporal roles of gross primary productivity (GPP), net primary productivity (NPP), and evapotranspiration (ET) in driving these efficiencies, and (3) examine temporal responses to WTD shifts. SWTD regions generally showed 12 to 18 % higher GPP, 10 to 15 % higher NPP, and 10 to 20 % higher ET than DWTD zones, especially in semi-arid croplands and forests, leading to 8 to 12 % higher CUE and WUE. However, in humid and heavily irrigated regions such as northeastern and hilly India, CUE was up to 10 % higher in DWTD zones, possibly due to reduced respiration and better soil aeration compared to SWTD areas affected by waterlogging. During the Kharif (wet) season, DWTD croplands in humid zones had higher efficiencies, while in the Rabi (dry) season, SWTD croplands in northern India benefited from irrigation and cooler temperatures. These results highlight strong influence of WTD on carbon and water use processes and support the need for region-specific groundwater strategies.

Carbon use efficiency↗

Techno-economic analysis of the water, energy, and greenhouse gas emissions impacts from the adoption of water efficiency practices in the U.S. manufacturing sector

Water is a critical resource for all of manufacturing. As such, mitigating risks to the supply of water to manufacturing plants facilitates maintaining a vital manufacturing sector. Reductions in water use through water efficiency is one method for mitigating risk, however little is known about its potential in the United States (U.S.) manufacturing sector. Herein, we address this gap and calculate the water reduction potential in U.S. manufacturing from commercially available water efficiency opportunities specific to the manufacturing sector. A list of water efficiency measures specific to the manufacturing sector is compiled and applied to estimates of U.S. manufacturing water withdrawals. The energy and carbon dioxide equivalent (CO 2 e) emission impacts from implementation of these measures are also quantified to better inform the resource, environmental, and economic trade-offs from implementation of these measures. We find that the water savings potential from the evaluated measures is up to 60 percent of U.S. manufacturing water withdrawal for certain subsectors, with the energy and emissions impact dependent on the measure. Further, we calculate the levelized cost of conserved water for several water efficiency measures (-$\$4,000$ to $\$85$/thousand m 3 , where negative values indicate net cost savings and positive values indicate net cost expenditures) and compare them to the levelized cost of alternative water sources ($\$600$ to $\$3,400$/thousand m 3 ). The results show significant opportunities for water and energy use reductions at levelized costs at least one order of magnitude lower than alternative water supplies, with some being revenue-generating.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Nexus of electrification and energy efficiency retrofit of commercial buildings at the district scale

Rapid electrification of buildings at the district scale is needed for cities to achieve climate change mitigation goals. However, most electrification studies focus on either the single building level or the city/region building stock level, and depend on the slow and uncertain process of requesting personally identifiable customer energy usage data from utilities. To answer a key question facing local policymakers: “Where can electrification proceed at scale without first upgrading the grid?” this study aims to quantify and inform building electrification impacts at the district scale using detailed building energy modeling and based on public records datasets. We explore how energy efficiency retrofits can help mitigate increased peak electric demand, and quantify impacts to energy use and carbon emissions. Building energy models of a baseline, and scenarios of simple electrification, energy retrofits, and electrification in combination with retrofits were created and simulated for 54 commercial buildings in two contiguous districts of San Francisco. A simple electrification scenario increased annual electricity consumption but reduced annual site energy usage by 15% to 17%, mainly due to replacing inefficient gas furnaces and boilers with more efficient heat pumps. Peak demand increased 7.4% for Fisherman's Wharf (e.g. within the capacity of the existing power grid), while the Design District showed a marginal decrease. Annual carbon emissions were reduced by 46% and 37%. Combining electrification with efficiency upgrades reduced peak demand by 26% and 40%, and annual carbon emissions by 63% and 64% for the two districts. Furthermore, these results indicate that impacts of electrification depend on the mix of building uses within a district, and coupling electrification with energy efficiency upgrades is an effective strategy to decarbonize buildings while maintaining or reducing the peak electric demand.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The fabrication of efficiency-improved W-series interconnect type of module by balancing the performance of single cells

Large dye-sensitized solar cells (DSCs) are usually fabricated as module types instead of single cell types, because the overall efficiency of an area-expanded single DSC is decreased by its large surface resistances and low fill factor (FF). The general DSC module designs are the parallel grid, series interconnect, and series monolithic types. The W-series interconnect type of module has some advantages, such as its easy fabrication and simple structure. Moreover, it also avoids the reduction in the FF. However, it has an efficiency imbalance between the single cells, because of the discrepancy in their luminous intensity. Therefore, the fabrication of the W-series interconnect type of module will be cost-effective only if the problem of its efficiency imbalance is solved. In this study, the thickness of the Pt layer, which has a very high reflection rate, and that of the electrolyte layer are minimized and the transmitted light is reflected by a metallic thin film in order to increase the number of photons absorbed by the dye molecules in the module. As a result, the performance of the efficiency-balanced W-module is improved by approximately 1% as compared to that of the conventional module. (author)

14 SOLAR ENERGY↗

High-speed, efficient metal - semiconductor - metal photodetectors

Design principles and the fabrication technique of highly efficient, high-speed photodetectors based on MSM nanostructures are developed. To efficiently confine light in the region of the strong field as well as to decrease light losses due to reflection from the diode contacts, use is made of a nanoscale interdigital diffraction grating and a multilayer Bragg grating. Measurements of the reflection coefficients and the quantum efficiency for a multilayer structure are in good agreement with theoretical estimates. A record-high quantum efficiency (QE = 46 %) is obtained for high speed MSM photodetectors. The detector has a high spectral selectivity ({Delta}{lambda}{sub 1/2} = 17 nm) at a wavelength of 800 nm. Taking into account the diode capacitance and the drift time of photogenerated carriers, the performance of the detectors under study is {approx} 500 GHz. The low level of the dark current density in the structures under study (j={sup 1} pA {mu}m{sup -2}) makes it possible to realise on their basis highly sensitive, high-speed selective detectors of optical radiation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantifying the Relationship Between Higher Photovoltaic Module Efficiency and the Adoption of Distributed Solar

The purpose of this study is understanding the relationship between module efficiency, system costs, and the economic and adoption potential of distributed rooftop solar. We use the dGen model to project the economic potential and adoption of high-efficiency photovoltaic (PV) modules across a range of efficiencies and cost scenarios in the continental United States. Our results reveal that high-efficiency modules can modestly increase the projected adoption of distributed solar, but system capital costs may play a larger role in changing the amount of projected adoption.

14 SOLAR ENERGY↗