Monte Carlo Driven MDI Optimization at a Muon Collider

A Muon Collider represents a very interesting possibility for a future machine to explore the energy frontier in particle physics. However, to reach the needed luminosity, beam intensities of the order of 10⁹–10¹² muons per bunch are needed. In this context, the Beam-Induced Background must be taken into account for its effects on magnets and detector. Several mitigation strategies can however be conceived. In this view, it is of crucial importance to develop a flexible tool that allows to easily reconstruct the machine geometry in a Monte Carlo code, allowing to simulate in detail the interaction of muon decay products in the machine, while being able to change the machine optics itself to find the best configuration. In this contribution, a possible approach to such a purpose is presented, based on FLUKA for the Monte Carlo simulation and on LineBuilder for the geometry reconstruction. Results based on the 1.5 TeV machine optics developed by the MAP collaboration are discussed, as well as a first approach to possible mitigation strategies.

43 PARTICLE ACCELERATORS↗

Field Emission Analysis in SRF Cavities for PIP-II Using GEANT4

Field emission (FE) remains a significant hurdle for achieving optimal performance and reliability in superconducting radiofrequency (SRF) cavities used in accelerator cryomodules. A thorough understanding of the generation and propagation of FE-induced radiation is therefore essential to mitigate this problem. The absence of standardized measurement protocols further complicates the comparison of radiation data across different testing phases and facilities. This highlights the need for a precise quantitative method to diagnose and analyze FE-induced radiation. Such efforts could prove beneficial for improving cavity preparation and cleanroom assembly techniques during the prototype and production stages of Fermilab's Proton Improvement Plan-II (PIP-II) project. This study presents the initial steps of detailed Geant4 simulations aimed at analyzing FE-induced radiation in the low-beta 650 MHz 5-cell elliptical (LB650) cavity. Our goal is to combine these results with radiation diagnostics to enhance diagnostic accuracy and optimize detector positioning. This integrated approach ultimately aims to improve the preparation, assembly, and testing procedures for PIP-II SRF cavities, ensuring the delivery of FE-free cryomodules.

Wijethunga, Sajini A.K. [Fermilab] (ORCID:00000002↗

Optimum frame synchronization.

This paper considers the optimum method for locating a sync word periodically imbedded in binary data and received over the additive white Gaussian noise channel. It is shown that the optimum rule is to select the location that maximizes the sum of the correlation and a correction term. Simulations are reported that show approximately a 3-dB improvement at interesting signal-to-noise ratios compared to a pure correlation rule. Extensions are given to the phase-shift keyed sync case where the detector output has a binary ambiguity and to the case of Gaussian data.

Massey, J. L.↗

Effects Of Phase Jitter On Lock Detection In QPSK

Report presents study of performances of digital carrier-signal-tracking loops used in reception of radio signals containing quadrature-phase-shift-keyed (QPSK) modulation representing binary non-return-to-zero data. Presents mathematical models of received signal and of noise. Describes lock-detector algorithm and presents equations characterizing lock-detection performance. Equations applied in analyses of three QPSK carrier-tracking loops: Costas crossover loop, maximum a posteriori estimation loop, and generalized Costas loop. Results of computer simulations agree with equations.

Mileant, Alexander↗

Secondary ion mass spectrometry (SIMS) analysis of hypervelocity microparticle impact sites on LDEF surfaces

Two dimensional elemental ion maps have been recorded for hundreds of microparticle impact sites and contamination features on LDEF surfaces. Since the majority of the analyzed surfaces were metal-oxide-silicon (MOS) impact detectors from the Interplanetary Dust Experiment, a series of 'standard' and 'blank' analyses of these surfaces are included. Hypervelocity impacts of forsterite olivine microparticles on activated flight sensors served as standards while stylus and pulsed laser simulated 'impacts' served as analytical blanks. Results showed that despite serious contamination issues, impactor residues can be identified in greater than 1/3 of the impact sites. While aluminum oxide particles could not be detected on aluminum surfaces, they were detected on germanium surfaces from row 12. Remnants of manmade debris impactors consisting of paint chips and bits of metal were identified on surfaces from LDEF Rows 3 (west or trailing side), 6 (south), 9 (ram or leading side), 12 (north) and the space end. Higher than expected ratios of manmade microparticle impacts to total microparticle impacts were found on the space end and the trailing side. These results were consistent with time-tagged and time-segregated microparticle impact data from the IDE and other LDEF experiments. A myriad of contamination interferences were identified and their effects on impactor debris identification mitigated during the course of this study. These interferences include pre-, post and inflight deposited surface contaminants as well as indigenous heterogeneous material contaminants. Non-flight contaminations traced to human origins, including spittle and skin oils, contributed significant levels of alkali-rich carbonaceous interferences. A ubiquitous layer of in-flight deposited silicaceous contamination varied in thickness with location on LDEF, even on a micro scale. In-flight deposited (low velocity) contaminants include urine droplets and bits of metal film from eroded thermal blankets.

Simon, C. G.↗

LUVOIR-ECLIPS Closed-Loop Adaptive Optics Performance and Contrast Predictions

One of the primary science goals of the Large UV/Optical/Infrared Surveyor (LUVOIR) mission concept is to detect and characterize Earth-like exoplanets orbiting nearby stars with direct imaging. The success of its coronagraph instrument ECLIPS (Extreme Coronagraph for Living Planetary Systems) depends on the ability to stabilize the wavefront from a large segmented mirror such that optical path differences are limited to tens of picometers RMS during an exposure time of a few hours. In order to relax the constraints on the mechanical stability, ECLIPS will be equipped with a wavefront sensing and control (WS\&C) architecture to correct wavefront errors up to temporal frequencies $\gtrsim$1 Hz. These errors may be dominated by spacecraft structural dynamics exciting vibrations at the segmented primary mirror. In this work, we present detailed simulations of the WS\&C system within the ECLIPS instrument and the resulting contrast performance. This study assumes wavefront aberrations based on a finite element model of a simulated telescope with spacecraft structural dynamics. Wavefront residuals are then computed according to a model of the adaptive optics system that includes numerical propagation to simulate a realistic wavefront sensor and an analytical model of the temporal performance. An end-to-end numerical propagation model of ECLIPS is then used to estimate the residual starlight intensity distribution at the science detector. We show that the contrast performance depends strongly on the target star magnitude and the spatio-temporal distribution of wavefront errors from the telescope. In cases with significant vibration, we advocate for the use of laser metrology to mitigate high temporal frequency wavefront errors and increase the mission yield.

Sirbu, Dan↗

Comparative assessment of neutron flux sensor technologies for advanced reactors

This report documents the comparative assessment of the rhodium-based self-powered neutron detectors (Rh-SPND), micro-pocket fission detectors (MPFD), and dosimetry wires in heated irradiations at the Neutron Radiography reactor facility at Idaho National Laboratory. The sensors performances are evaluated high-temperature environments (upwards of 850°C) during maximum reactor power to simulate use in advanced reactor applications. The performance of the Rh-SPNDs indicates the experiment cartridge heater power supply interferes with the SPND signals. This interference become increasingly significant at temperatures above 500°C with minimal interference observed for temperatures below 500°C. This work also demonstrated the fabrication process for the updated design of the MPFD, but issues related to the seal welds were identified and usable data was limited. Finally, the dosimetry measurements were within the expected range correlated with reactor power; thus, the dosimetry results were used to provide preliminary SPND calibration factors. The results from this experiment serves as a reference for developing and testing of flux sensors that are designed for high-temperature irradiations and advanced reactor deployments. This includes upcoming FY22 irradiations at the Massachusetts Institute of Technology Reactor and the Neutron Radiography (NRAD) reactor utilizing additional fission chambers from Photonis Technologies and fission chambers and SPNDs from The French Alternative Energies and Atomic Energy Commission.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Field Emission Analysis in SRF Cavities for PIP-II Using GEANT4

Field emission (FE) remains a significant hurdle for achieving optimal performance and reliability in super-conducting radiofrequency (SRF) cavities used in accelerator cryomodules. A thorough understanding of the generation and propagation of FE-induced radiation is therefore essential to mitigate this problem. The absence of standardized measurement protocols further complicates the comparison of radiation data across different testing phases and facilities. This highlights the need for a precise quantitative method to diagnose and analyze FE-induced radiation. Such efforts could prove beneficial for improving cavity preparation and cleanroom assembly techniques during the prototype and production stages of Fermilab's Proton Improvement Plan-II (PIP-II) project. This study presents the initial steps of detailed Geant4 simulations aimed at analyzing FE-induced radiation in the low-beta 650 MHz 5-cell elliptical (LB650) cavity. Our goal is to combine these results with radiation diagnostics to enhance diagnostic accuracy and optimize detector positioning. This integrated approach ultimately aims to improve the preparation, assembly, and testing procedures for PIP-II SRF cavities, ensuring the delivery of FE-free cryomodules.

Wijethunga, S. A.K. [Fermilab] (ORCID:000000028765↗

Comparison of ACHILLES and GENIE Observables for DUNE-PRISM and the SBN Program, with New 2p2h Predictions

The DUNE near detector LAr-TPC can be moved to different off-axis positions to sample different neutrino fluxes, which in turn will yield different cross section distributions for observables. Several DUNE ND off axis locations were simulated using GENIE and ACHILLES, and generator differences and FSI contributions were examined for various observables. Additionally, the predictions were compared with those of existing experiments, and it is shown that the DUNE ND 20m off axis predictions are similar to that of MicroBooNE for various observables. Finally, the 2p2h interaction mode was simulated for ACHILLES for the first time for ICARUS, and a preliminary comparison is made to MicroBooNE data and simulations from different event generators.

Dumont, Daniel [Fermilab]↗

Biomarkers Detection With the Autonomous and Remotely Operated SOLID-LDChip Instrument in A Mars Drilling Simulating Campaign

One of the main goals in Mars exploration is to determine whether life has ever existed on the red planet. To achieve this goal, it is important to verify the performance, robustness, and maturity of instrumentation devoted to life detection, for example through field-testing in Mars analog environments.The Atacama Desert is considered one of the best terrestrial analogs of the surface of Mars due to abrupt temperature shifts, dryness, high UV radiation, and extremely low biomass. This, together with the lack of vegetation and the geochemistry of the regolith, make it an ideal scenario for testing instrumentation, performance, and concepts of operations. The Atacama Rover Astrobiology Drilling Studies (ARADS) is a NASA PSTAR project conceived for maturing and testing life-detection instrumentation in the Atacama Desert(1). The project is based on the K-REX2 rover equipped with a robotic 1-meter arm that delivers samples toon board instruments. This includes SOLID3.1 (Signs of Life Detector), designed as a life-detection instrument for finding complex organic molecules by means of the LDCHip (Life Detector Chip), an antibody microarray sensor(2). The instrument can extract organic compounds from soil, rocks, and sediments into a liquid solvent in the extraction cell (EC), allowing the search for hundreds of microbial molecular biomarkers at once (3). The robustness and reliability of SOLID were tested in the 2019 ARADS Mars drilling simulating campaign and confirmed with other analytical methods.

M Moreno-Paz↗

Observing Ice Sublimation From Water-Doped Lunar Simulant at Cryogenic Temperatures

NASA's Resource Prospector (RP) mission is intended to characterize the three-dimensional nature of volatiles in lunar polar and permanently shadowed regions. The Near-Infrared Volatile Spectrometer System (NIRVSS) observes while a drill penetrates to a maximum depth of 1 m. Any 10 cm increment of soil identified as containing water ice can be delivered to a heating crucible with the evolved gas delivered to a gas chromatograph / mass spectrometer. NIRVSS consists of two components; a spectrometer box (SB) and bracket assembly (BA), connected by two fiber optic cables. The SB contains separate short- and long-wavelength spectrometers, SW and LW respectively, that collectively span the 1600-3400 nm range. The BA contains an IR emitter (lamp), drill observation camera (DOC, 2048 x 2048 CMOS detector), 8 different wavelength LEDs, and a longwave calibration sensor (LCS) measuring the surface emissivity at four IR wavelengths. Tests of various RP sub-systems have been under-taken in a large cryo-vacuum chamber at Glenn Re-search Center. The chamber accommodates a tube (1.2 m high x 25.4 cm diameter) filled with lunar simulant, NU-LHT-3M, prepared with known abundances of water. Thermocouples are embedded at different depths, and also across the surface of the soil tube. In the chamber the tube is cooled with LN2 as the pressure is reduced to approx. 5-6x10(exp -6) Torr. For the May 2016 tests two soil tubes were prepared with initially 2.5 Wt.% water. The shroud surrounding the soil tube was held at different temperatures for each tube to simulate a warm and cold lunar environment. Table 1 provides a summary of experimental conditions and Figure 1 shows the nominal view of the NIRVSS components, the drill foot, and the top of the soil tube. Once the average soil temperature reached approx. 178 K, drilling commenced. During drilling activities NIRVSS was alternating between obtaining spectra and obtaining images. Here we discuss NIRVSS spectral data obtained during controlled drill percussions.

Roush, T. L.↗

The Mini Astrophysical MeV Background Observatory (MAMBO) CubeSat mission

The origin of the cosmic diffuse gamma-ray (CDG) background in the 0.3 – 30 MeV energy range is a mystery that has persisted for over 40 years. The Mini Astrophysical MeV Background Observatory (MAMBO) is a CubeSat mission concept motivated by the fact that, since the MeV CDG is relatively bright, only a small detector is required to make highquality measurements of it. Indeed, the sensitivity of space-based gamma-ray instruments to the CDG is limited not by size, but by the locally generated instrumental background produced by interactions of energetic particles in spacecraft materials. Comparatively tiny CubeSat platforms provide a uniquely quiet environment relative to previous gamma-ray science missions. The MAMBO mission will provide the best measurements ever made of the MeV CDG spectrum and angular distribution, utilizing two key innovations: 1) low instrumental background on a 12U CubeSat platform; and 2) an innovative shielded spectrometer design that simultaneously measures signal and background. We describe the MAMBO instrument and mission concept in detail, including simulations and laboratory measurements demonstrating the key measurement concept.

Astronomy and astrophysics↗

The CMOS Pseudo-Thyristor: a zero-static current discriminator circuit

We report a very low power discriminator circuit for pixelized detectors, called the Pseudo-Thyristor is described in this document. It is a positive feedback topology using regular PMOS and NMOS field-effect transistors (FET's) with zero static current. When a small charge is injected into the circuit, it flips rapidly due to the positive feedback and outputs a logic transition for further digitization. Simulation shows that in a 65 nm process, it is possible to achieve a detecting threshold below 5 fC while maintain the average power consumption below 10 micro-Watts when the hit occupancy is <10% for 40 MHz operation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Retrieval of energy spectra for all flavours of neutrinos from core-collapse supernova with multiple detectors

ABSTRACT We present a new method by which to retrieve energy spectrum for all falvours of neutrinos from core-collapse supernova (CCSN). In the retrieval process, we do not assume any analytic formulas to express the energy spectrum of neutrinos but rather take a direct way of spectrum reconstruction from the observed data; the singular value decomposition algorithm with a newly developed adaptive energy-gridding technique is adopted. We employ three independent reaction channels having different flavour sensitivity to neutrinos. Two reaction channels, inverse beta decay on proton and elastic scattering on electrons, from a water Cherenkov detector such as Super-Kamiokande (SK) and Hyper-Kamiokande (HK), and a charged current reaction channel with Argon from the Deep Underground Neutrino Experiment (DUNE) are adopted. Given neutrino oscillation models, we iteratively search the neutrino energy spectra at the CCSN source until they provide the consistent event counts in the three reaction channels. We test the capability of our method by demonstrating the spectrum retrieval to a theoretical neutrino data computed by our recent three-dimensional CCSN simulation. Although the energy spectrum with either electron-type or electron-type antineutrinos at the CCSN source has relatively large error compared to that of other species, the joint analysis with HK + DUNE or SK + DUNE will provide precise energy spectrum of all flavours of neutrinos at the source. Finally, we discuss perspectives for improvements of our method by using neutrino data of other detectors.

79 ASTRONOMY AND ASTROPHYSICS↗

Description of the Electronic Structure of Oxyhemoglobin Using Fe L-Edge X-ray Absorption Spectroscopy

The electronic structure of oxyhemoglobin has been controversial since the discovery of the compound’s diamagnetism in 1936. Here, this study uses partial fluorescence yield Fe L-edge X-ray absorption spectroscopy (XAS) in the 3s→2p fluorescence on oxyhemoglobin solutions, measured using a transition-edge sensor detector, to obtain a quantitative experimental description of the electronic structure of the O 2 -bound iron site. The spectrum is very different from typical low-spin Fe II and Fe III heme spectra, and multiplet simulations indicate a mixed ground configuration with ∼57% low-spin Fe III and ∼43% low-spin Fe II character. This is also very different from the Fe II character found for the picket-fence porphyrin model complex. The oxyhemoglobin L-edge XAS data further show that the O 2 ligand engages in a weak σ- but strong π-bond with the iron ion, leading to the overall strong Fe–O 2 bond required for O 2 transport.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An updated estimate of the Mu2e experiment sensitivity

The Mu2e experiment at Fermilab will search for the conversion of a negative muon into an electron inside the field of a nucleus. This process does not conserve charged-lepton flavour and is heavily suppressed in the Standard Model (SM), with a branching ratio < 10-50. Any evidence of it would be an undeniable evidence of new physics beyond the SM. The project sets out to achieve a single event sensitivity of $\sim 3 × 10^{-17}$ on the ratio between the probability for a conversion of a negative muon into an electron and the one for a muon capture by the nucleus. Such a sensitivity would represent a 4 orders of magnitude improvement on the previous upper limit for the process, making possible to test predictions of different extensions of the SM. Mu2e uses three superconducting solenoids to produce and measure the muon conversions. In the first solenoid, the Production Solenoid, pions and kaons are produced, together with other secondary products, by 8 GeV kinetic energy proton interactions in a tungsten target. A gradient magnetic field is specifically designed to direct low momentum particles into the Transport Solenoid, an S-shaped magnet that filters out particles with unwanted charge and momentum. Muons, produced by pion and kaon decays, finally reach the aluminum Stopping Target in the Detector Solenoid, where they eventually stop and convert. The result of the conversion process is a monochromatic electron of ~105 MeV/c momentum. The Detector Solenoid also hosts the two main detectors: a straw tube tracker and two CsI calorimeter disks, both providing measurement of event kinematics. A germanium detector and a LaBr crystal are located downstream of the Detector Solenoid to measure the X and gamma rays produced by the muon captures in the Stopping Target. A veto system of scintillators covering the Detector Solenoid and half of the Transport Solenoid is used to identify and reject cosmic rays interactions. With respect to the initial project, the Mu2e running plan has evolved to a staged configuration with 2 years at reduced intensity before the 2025 accelerator shutdown for the neutrino beam upgrade and 2 or 3 years at full intensity after that. This, together with geometry changes and a better knowledge of detector performances obtained by the first slice tests, has required a full revision of the signal over background selection that is the subject of this thesis. In order to achieve a new estimate of Mu2e sensitivity, the simulation of the data corresponding to the first 2 years of data acquisition has been performed. This includes both conversion electrons (CE) and the main sources of background: cosmics, decay-in orbits (DIO), radiative pion captures (RPC) and antiprotons. The characteristics of the signal and of the main backgrounds have been studied to define the best selection variables for CE. A special effort has been devoted to the evaluation of the antiproton background. The lack of experimental data for antiproton production cross section makes the systematic uncertainty on this background significant. A new parameterization of the cross section has been developed to fit the existing data and to provide a more reliable estimate of the systematic uncertainty by comparing the results of the old and the new model. A special effort has been devoted to the optimization of the antiprotons Monte Carlo generator. This study has also revealed that the dominant component within this background is represented by antiprotons produced in the opposite direction with respect to the Transport Solenoid entrance and then redirected to it by back-scattering processes in the Production Target. This ultimately highlights the sensitivity of the background estimate to the G4 handling of antiproton interactions in the 1 to 3 GeV/c momentum range. Finally, the final experimental sensitivity has been studied. The momentum and time selection have been optimized to obtain the 5-sigma discovery reach or, in case of no signal, the upper limit on conversion probability. The results confirm that, in the firs t two years of data taking, Mu2e will be able to improve the current experimental sensitivity for muon-to-electron conversion in an atomic field by more than 3 order of magnitudes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Efficiency Studies of Fast Neutron Tracking Using MCNP

Fast neutron identification and spectroscopy is of great interest to nuclear physics experiments. Using the neutron elastic scattering, the fast neutron momentum can be measured. Wang and Morris introduced the theoretical concept that the initial fast neutron momentum can be derived from up to three consecutive elastic collisions between the neutron and the target, including the information of two consecutive recoil ion tracks and the vertex position of the third collision or two consecutive elastic collisions with the timing information. Here, we also include the additional possibility of measuring the deposited energies from the recoil ions. In this paper, we simulate the neutron elastic scattering using the Monte Carlo N-Particle Transport Code (MCNP) and study the corresponding neutron detection and tracking efficiency. The corresponding efficiency and the scattering distances are simulated with different target materials, especially natural silicon (92.23%28Si, 4.67%29Si, and 3.1%30Si) and helium-4 (4He). The timing of collision and the recoil ion energy are also investigated, which are important characters for the detector design. We also calculate the ion traveling range for different energies using the software, “The Stopping and Range of Ions in Matter (SRIM)”, showing that the ion track can be most conveniently observed in 4He unless sub-micron spatial resolution can be obtained in silicon.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Study of a flight monitor for jet engine disk cracks using the critical length criterion of fracture mechanics

A disk crack detector is discussed which is intended to operate while in flight. The crack detector monitors the disk rim for radial surface cracks emanating from the blade root interface. An eddy current type sensor with a remotely located capacitance-resistance bridge and signal analyzer is able to detect reliably a simulated crack 1/8 in. long. The sensor was tested at rim velocities of 600 fps and at 1000 F. Fracture mechanics is used to calculate the critical crack length. Knowledge of the crack growth rate permits the calculation of the number of stress cycles remaining for the detected crack to grow to critical size. A plot is presented of the remaining life as a function of the critical crack length and the operating stress. It is shown that for a disk of Inconel 718 a through-the-thickness crack operating under a rim stress of 50 kpsi has a critical length of 0.7-in. and a remaining life of 130 flights.

Barranger, J. P.↗