Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “data quality assessment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

MERRA-2 Input Observations: Summary and Assessment

The Modern-Era Retrospective Analysis for Research and Applications, Version 2 (MERRA-2) is an atmospheric reanalysis, spanning 1980 through near-realtime, that uses state-of-the-art processing of observations from the continually evolving global observing system. The effectiveness of any reanalysis is a function not only of the input observations themselves, but also of how the observations are handled in the assimilation procedure. Relevant issues to consider include, but are not limited to, data selection, data preprocessing, quality control, bias correction procedures, and blacklisting. As the assimilation algorithm and earth system models are fundamentally fixed in a reanalysis, it is often a change in the character of the observations, and their feedbacks on the system, that cause changes in the character of the reanalysis. It is therefore important to provide documentation of the observing system so that its discontinuities and transitions can be readily linked to discontinuities seen in the gridded atmospheric fields of the reanalysis. With this in mind, this document provides an exhaustive list of the input observations, the context under which they are assimilated, and an initial assessment of selected core observations fundamental to the reanalysis.

Satellite Observations↗

SU-F-J-116: Clinical Experience-Based Verification and Improvement of a 4DCT Program

Purpose: To demonstrate the role of continuous improvement fulfilled by the Medical Physicist in clinical 4DCT and CBCT scanning. Methods: Lung (SABR and Standard) patients’ 4D respiratory motion and image data were reviewed over a 3, 6 and 12 month period following commissioning testing. By identifying trends of clinically relevant parameters and respiratory motions, variables were tested with a programmable motion phantom and assessed. Patient traces were imported to a motion phantom and 4DCT and CBCT imaging were performed. Cos6 surrogate and sup-inf motion was also programmed into the phantom to simulate the long exhale of patients for image contrast tests. Results: Patient surrogate motion amplitudes were 9.9+5.2mm (3–35) at 18+6bpm (6–30). Expiration/Inspiration time ratios of 1.4+0.5second (0.6–2.9) showed image contrast effects evident in the AveCT and 3DCBCT images. Small differences were found for patients with multiple 4DCT data sets. Patient motion assessments were simulated and verified with the phantom within 2mm. Initial image reviews to check for reconstructed artefacts and data loss identified a small number of patients with irregularities in the automatic placement of inspiration and expiration points. Conclusion: The Physicist’s involvement in the continuous improvements of a clinically commissioned technique, processes and workflows continues beyond the commissioning stage of a project. Our experience with our clinical 4DCT program shows that Physics presence is required at the clinical 4DCT scan to assist with technical aspects of the scan and also for clinical image quality assessment prior to voluming. The results of this work enabled the sharing of information from the Medical Physics group with the Radiation Oncologists and Radiation Therapists. This results in an improved awareness of clinical patient respiration variables and how they may affect 4D simulation images and also may also affect the treatment verification images.

60 APPLIED LIFE SCIENCES↗

Assessment of simulation fidelity using measurements of piloting technique in flight

The U.S. Army and NASA have undertaken the systematic validation of a ground-based piloted simulator for the UH-60A helicopter. The results of previous handling quality and task performance flight tests for this helicopter have been used as a data base for evaluating the fidelity of the present simulation, which is being conducted at the NASA Ames Research Center's Vertical Motion Simulator. Such nap-of-the-earth piloting tasks as pop-up, hover turn, dash/quick stop, sidestep, dolphin, and slalom, have been investigated. It is noted that pilot simulator performance is significantly and quantifiable degraded by comparison with flight test results for the same tasks.

Ferguson, S. W.↗

Annual Transuranic Waste Inventory Report - 2008 (Rev. 0)

The U.S. Department of Energy’s (DOE’s) Waste Isolation Pilot Plant (WIPP) opened on March 26, 1999, becoming the nation’s first deep geologic repository for the permanent disposal of defense-generated transuranic (TRU) waste. TRU waste generation has occurred at 39 sites across the country (seven large-quantity and 32 small-quantity sites). Sixteen of these sites (one large site and 15 small quantity sites) have emplaced their waste at WIPP, found other disposition pathways for the waste, or have transferred the waste to other sites for further disposition (LANL-CO, 2007a). Babcock and Wilcox (BL) [this site did not pursue a defense determination and was considered deinventoried], United States Army Materiel Command (USAMC), Knolls Atomic Power Laboratory – Nuclear Fuels Service (KAPL-NFS), and Lawrence Berkeley National Laboratory (LBNL) have been de-inventoried once, but have identified additional waste after the originally identified waste was removed from the site. TRU waste is currently retrievably stored at 23 sites throughout the DOE complex. As of December 31, 2007, there have been 6340 shipments of TRU waste to WIPP for emplacement since WIPP’s opening (DOE 2008a). Since 1994, DOE complex-wide TRU waste inventory information has been collected, analyzed, and published for WIPP certification urposes in several reports. The WIPP Transuranic Waste Baseline Inventory Report (WTWBIR), Revision 0, published in June 1994 (DOE 1994), was the first attempt made by the DOE complex to report all of its TRU waste at the waste-stream level. The TRU waste data reported in Revision 0 were considered preliminary until the TRU waste sites completed quality checks of the data. Data changes resulting from the quality checks were contained in the WTWBIR, Revision 1 (DOE 1995a). The Transuranic Waste Baseline Inventory Report (TWBIR), Revisions 2 and 3, included WIPP and potential TRU waste streams, along with waste stream characteristic information. Data from Revisions 2 and 3 provided the TRU waste inventory that Sandia National Laboratories–Carlsbad Programs Group (SNL-CPG) used to perform the necessary modeling calculations for the performance assessment (PA) for the initial certification of the WIPP (Compliance Certification Application [CCA]).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analyzing inference workloads for spatiotemporal modeling

Ensuring power grid resiliency, forecasting climate conditions, and optimization of transportation infrastructure are some of the many application areas where data is collected in both space and time. Spatiotemporal modeling is about modeling those patterns for forecasting future trends and carrying out critical decision-making by leveraging machine learning/deep learning. Once trained offline, field deployment of trained models for near real-time inference could be challenging because performance can vary significantly depending on the environment, available compute resources and tolerance to ambiguity in results. Users deploying spatiotemporal models for solving complex problems can benefit from analytical studies considering a plethora of system adaptations to understand the associated performance-quality trade-offs. To facilitate the co-design of next-generation hardware architectures for field deployment of trained models, it is critical to characterize the workloads of these deep learning (DL) applications during inference and assess their computational patterns at different levels of the execution stack. In this paper, we develop several variants of deep learning applications that use spatiotemporal data from dynamical systems. We study the associated computational patterns for inference workloads at different levels, considering relevant models (Long short-term Memory, Convolutional Neural Network and Spatio-Temporal Graph Convolution Network), DL frameworks (Tensorflow and PyTorch), precision (FP16, FP32, AMP, INT16 and INT8), inference runtime (ONNX and AI Template), post-training quantization (TensorRT) and platforms (Nvidia DGX A100 and Sambanova SN10 RDU). Overall, our findings indicate that although there is potential in mixed-precision models and post-training quantization for spatiotemporal modeling, extracting efficiency from contemporary GPU systems might be challenging. Instead, co-designing custom accelerators by leveraging optimized High Level Synthesis frameworks (such as SODA High-Level Synthesizer for customized FPGA/ASIC targets) can make workload-specific adjustments to enhance the efficiency.

97 MATHEMATICS AND COMPUTING↗

Seismic source characterization of the Arabian Peninsula and Zagros Mountains from regional moment tensor and coda envelopes

Reliable estimates of moment magnitude and source mechanism for seismic events in the Middle East can be challenging due to a small number of openly available stations, the complex tectonic setting, and regions of high attenuation. Access to high-quality waveform data from well-calibrated regional seismic stations is fundamental in producing robust and stable estimates of earthquake source parameters, particularly when measurements of absolute ground motion amplitudes are required. Earthquake source mechanism and moment magnitude are invaluable information in the assessment of seismic hazard, plate motions, and the characterization of faults and regional stress field. The expansion of the Kingdom of Saudi Arabia’s national seismic network in the past several decades provides an opportunity to develop the capabilities of routine focal mechanism and moment magnitude estimations. In this study, we use time-domain full waveform moment tensor inversion and coda envelope–derived amplitude measurements to solve for earthquake source mechanism, moment magnitudes, and their source type. Furthermore, we compared the moment magnitudes calculated from the two methods and publicly available earthquake catalogs and discuss the implications of the obtained source parameters.

58 GEOSCIENCES↗

An evaluation of air quality in major urban areas of India

Rapid economic growth and burgeoning population have contributed to enhanced levels of PM 2.5 concentrations in urban regions of India. Evaluation of ambient air quality facilitates the assessment of effectiveness of emission control measures and early identification of new sources. This study provides a comprehensive statistical analysis of PM 2.5 concentrations in key urban areas across India, including Delhi, Kolkata, Mumbai, Chennai, Hyderabad, and several regional centers. Data from 2017 to 2023 was analyzed using trend analysis, cluster analysis, principal component analysis, and geostatistical interpolation to understand spatiotemporal variations and sources. The analysis reveals significant differences in spatial distribution of PM 2.5 concentrations with high annual averages in urban regions in Indo-Gangetic plain (82–123 μg m −3 ) and relatively lower concentrations (29–46 μg m −3 ) in southern urban areas of Kerala, Tamil Nadu and Andhra Pradesh. Delhi state had the highest 24-averaged PM 2.5 concentrations (112 μg m −3 ) followed by urban regions in Uttar Pradesh, Bihar and West Bengal (94 μg m −3 ). Trend analysis from 2017 to 2023 revealed an overall 2.5% decline in site-wide PM2.5 concentrations, with the exception of Ludhiana, which exhibited a consistent annual increase of 10%. Principal component analysis (PCA) attributes 30% of the variance to wintertime emissions, 13% to biomass burning, and 18% to the regional haze in the northern Indo-Gangetic Plain. Different analyses clearly demonstrates the contribution of biomass burning to pollution in Delhi and surrounding cities. Transboundary pollution to Kolkata is likely from the highly polluted region in Indo-Gangetic Plain. Coastal cities of Mumbai and Chennai has relatively lower pollution attributed to the influence of sea breeze dilution, with mostly local contribution and some potential transport from upwind industry clusters. Hyderabad also has local contribution due to high density of vehicular traffic and local small industries. This study shows that mitigation efforts targeting clusters of regions should be undertaken to curb the high PM2.5 pollution. Policy measures should be implemented both at local and the intra-state level to address shared sources and transport of pollution.

Hysplitbacktrajectories↗

Static and dynamic properties of multi-ionic plasma mixtures

Complex plasma mixtures with three or more components are often encountered in astrophysics or in inertial confinement fusion (ICF) experiments. For mixtures containing species with large differences in atomic number Z, the modeling needs to consider at the same time the kinetic theory for low-Z elements combined with the theory of strongly coupled plasma for high-Z elements, as well as all the intermediate situations that can appear in multi-component systems. For such cases, we study the pair distribution functions, self-diffusions, mutual diffusion and viscosity for ternary mixtures at extreme conditions. These quantities can be produced from first principles using orbital free molecular dynamics at the computational expense of very intensive simulations to reach good statistics. Utilizing the first-principles results as reference data, we assess the merit of a global analytic model for transport coefficients, "Pseudo-Ions in Jellium" (PIJ), based on an iso-electronic assumption (iso-n e ). With a multi-component hypernetted-chain integral equation, we verify the quality of the iso-n e prescription for describing the static structure of the mixtures. This semi-analytical modeling compares well with the simulation results and allows one to consider plasma mixtures not accessible to simulations. Further, applications are given for the mix of materials in ICF experiments. A reduction of a multicomponent mixture to an effective binary mixture is also established in the hydrodynamic limit and compared with PIJ estimations for ICF relevant mixtures.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Crystallographic variant mapping using precession electron diffraction data

In this work, we developed three methods to map crystallographic variants of samples at the nanoscale by analyzing precession electron diffraction data using a high-temperature shape memory alloy and a VO2 thin film on sapphire as the model systems. The three methods are (I) a user-selecting-reference pattern approach, (II) an algorithm-selecting-reference-pattern approach, and (III) a k-means approach. In the first two approaches, Euclidean distance, Cosine, and Structural Similarity (SSIM) algorithms were assessed for the diffraction pattern similarity quantification. We demonstrated that the Euclidean distance and SSIM methods outperform the Cosine algorithm. We further revealed that the random noise in the diffraction data can dramatically affect similarity quantification. Denoising processes could improve the crystallographic mapping quality. With the three methods mentioned above, we were able to map the crystallographic variants in different materials systems, thus enabling fast variant number quantification and clear variant distribution visualization. The advantages and disadvantages of each approach are also discussed. We expect these methods to benefit researchers who work on martensitic materials, in which the variant information is critical to understand their properties and functionalities.

Crystallographic variant mapping↗

Validation and Calibration of Nuclear Thermal Hydraulics Multiscale Multiphysics Models - Subcooled Flow Boiling Study

In addition to validation data plan, development of advanced techniques for calibration and validation of complex multiscale, multiphysics nuclear reactor simulation codes are a main objective of the CASL VUQ plan. Advanced modeling of LWR systems normally involves a range of physico-chemical models describing multiple interacting phenomena, such as thermal hydraulics, reactor physics, coolant chemistry, etc., which occur over a wide range of spatial and temporal scales. To a large extent, the accuracy of (and uncertainty in) overall model predictions is determined by the correctness of various sub-models, which are not conservation-laws based, but empirically derived from measurement data. Such sub-models normally require extensive calibration before the models can be applied to analysis of real reactor problems. This work demonstrates a case study of calibration of a common model of subcooled flow boiling, which is an important multiscale, multiphysics phenomenon in LWR thermal hydraulics. The calibration process is based on a new strategy of model-data integration, in which, all sub-models are simultaneously analyzed and calibrated using multiple sets of data of different types. Specifically, both data on large-scale distributions of void fraction and fluid temperature and data on small-scale physics of wall evaporation were simultaneously used in this work’s calibration. In a departure from traditional (or common-sense) practice of tuning/calibrating complex models, a modern calibration technique based on statistical modeling and Bayesian inference was employed, which allowed simultaneous calibration of multiple sub-models (and related parameters) using different datasets. Quality of data (relevancy, scalability, and uncertainty) could be taken into consideration in the calibration process. This work presents a step forward in the development and realization of the “CIPS Validation Data Plan” at the Consortium for Advanced Simulation of LWRs to enable quantitative assessment of the CASL modeling of Crud-Induced Power Shift (CIPS) phenomenon, in particular, and the CASL advanced predictive capabilities, in general. This report is prepared for the Department of Energy’s Consortium for Advanced Simulation of LWRs program’s VUQ Focus Area.

97 MATHEMATICS AND COMPUTING↗

Flight-determined engine exhaust characteristics of an F404 engine in an F-18 airplane

Personnel at the NASA Langley Research Center (NASA-Langley) and the NASA Dryden Flight Research Facility (NASA-Dryden) recently completed a joint acoustic flight test program. Several types of aircraft with high nozzle pressure ratio engines were flown to satisfy a twofold objective. First, assessments were made of subsonic climb-to-cruise noise from flights conducted at varying altitudes in a Mach 0.30 to 0.90 range. Second, using data from flights conducted at constant altitude in a Mach 0.30 to 0.95 range, engineers obtained a high quality noise database. This database was desired to validate the Aircraft Noise Prediction Program and other system noise prediction codes. NASA-Dryden personnel analyzed the engine data from several aircraft that were flown in the test program to determine the exhaust characteristics. The analysis of the exhaust characteristics from the F-18 aircraft are reported. An overview of the flight test planning, instrumentation, test procedures, data analysis, engine modeling codes, and results are presented.

Ennix, Kimberly A.↗

Handling Qualities Specifications for U.S. Military Helicopters

Inadequacies in the military specification for helicopter handling qualities, MIL-H-8501A, have long been recognized, and the latest procurements by the U.S. Army used special Prime Item Development Specifications (PIDS). This paper assesses the efficacy of these PIDS and suggests that changes should be made. In particular, the structure developed in MIL-F-8785B (ASG) (the specification for flying qualities of piloted airplanes) should be incorporated. Improved requirements must be based on a systematic data base and concentrated on topics most important in preliminary design: static and dynamic stability, control power and sensitivity, and interaction with controllers and displays. Emphasis should be on current military helicopter missions and helicopter idiosyncrasies such as cross-coupling, nonlinearities, and higher-order dynamics.

Key, David L.↗

Novel Hyperspectral Sun Photometer for Satellite Remote Sensing Data Radiometeic Calibration and Atmospheric Aerosol Studies

A simple and cost-effective, hyperspectral sun photometer for radiometric vicarious remote sensing system calibration, air quality monitoring, and potentially in-situ planetary climatological studies, was developed. The device was constructed solely from off the shelf components and was designed to be easily deployable for support of short-term verification and validation data collects. This sun photometer not only provides the same data products as existing multi-band sun photometers but also the potential of hyperspectral optical depth and diffuse-to-global products. As compared to traditional sun photometers, this device requires a simpler setup, less data acquisition time and allows for a more direct calibration approach. Fielding this instrument has also enabled Stennis Space Center (SSC) Applied Sciences Directorate personnel to cross-calibrate existing sun photometers. This innovative research will position SSC personnel to perform air quality assessments in support of the NASA Applied Sciences Program's National Applications program element as well as to develop techniques to evaluate aerosols in a Martian or other planetary atmosphere.

Pagnutti, Mary↗

NASA DEVELOP Students Rev Up Response to Gulf Oil Spill

After the April 20th explosion aboard the Deepwater Horizon drilling rig in the Gulf of Mexico, the world witnessed one of the worst oil spill catastrophes in global history. In an effort to mitigate the disaster, the U.S. government moved quickly to establish a unified command for responding to the spill. Some of the command's most immediate needs were to track the movement of the surface oil slick, establish a baseline measurement of pre-oil coastal ecosystem conditions, and assess potential air quality and water hazards related to the spill. To help address these needs and assist the Federal response to the disaster, NASA deployed several of its airborne and satellite research sensors to collect an unprecedented amount of remotely-sensed data over the Gulf of Mexico region. Although some of these data were shared with the public via the media, much of the NASA data on the disaster was not well known to the Gulf Coast community. The need existed to inform the general public about these datasets and help improve understanding about how NASA's science research was contributing to oil spill response and recovery. With its extensive experience conducting community-oriented remote sensing projects and close ties to organizations around Gulf of Mexico, the NASA DEVELOP National Program stood in a unique position to meet this need.

Jones, Jason B.↗

Quality Assessment in Oncology

The movement to improve healthcare quality has led to a need for carefully designed quality indicators that accurately reflect the quality of care. Many different measures have been proposed and continue to be developed by governmental agencies and accrediting bodies. However, given the inherent differences in the delivery of care among medical specialties, the same indicators will not be valid across all of them. Specifically, oncology is a field in which it can be difficult to develop quality indicators, because the effectiveness of an oncologic intervention is often not immediately apparent, and the multidisciplinary nature of the field necessarily involves many different specialties. Existing and emerging comparative effectiveness data are helping to guide evidence-based practice, and the increasing availability of these data provides the opportunity to identify key structure and process measures that predict for quality outcomes. The increasing emphasis on quality and efficiency will continue to compel the medical profession to identify appropriate quality measures to facilitate quality improvement efforts and to guide accreditation, credentialing, and reimbursement. Given the wide-reaching implications of quality metrics, it is essential that they be developed and implemented with scientific rigor. The aims of the present report were to review the current state of quality assessment in oncology, identify existing indicators with the best evidence to support their implementation, and propose a framework for identifying and refining measures most indicative of true quality in oncologic care.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Experimental, Economic, and Environmental Assessment of Feedstock Gasification for High-Octane Fuel Production

Five economically advantaged biomass feedstocks identified in the US Department of Energy's 2016 Billion Ton Study were gasified and the syngas reformed at the bench scale to study the feedstock price-performance relationship. The distribution of reformed syngas compositions, heating values, and yields were similar across the different feedstocks and blends thereof, which ranged from inexpensive residual wastes to more expensive and higher quality biomass, revealing that feedstock performance was mostly insensitive to its price. Custom blended feedstocks produced syngas with characteristics resembling linear combinations of syngas from single-component feedstocks, supporting the ability to customize and predict blended properties based on single-feedstock data. A techno-economic analysis of specific feedstock costs for producing high-octane gasoline showed that miscanthus and forest residues were the most cost-effective. A field-to-wheels life-cycle assessment of greenhouse gas emissions showed that forest residues was the most environmentally benign feedstock of those studied.

09 BIOMASS FUELS↗

Construction of Polarimetric Radar-Based Reference Rain Maps for the Iowa Flood Studies Campaign

The Global Precipitation Measurement (GPM) Mission Iowa Flood Studies (IFloodS) campaign was conducted in central and northeastern Iowa during the months of April-June, 2013. Specific science objectives for IFloodS included quantification of uncertainties in satellite and ground-based estimates of precipitation, 4-D characterization of precipitation physical processes and associated parameters (e.g., size distributions, water contents, types, structure etc.), assessment of the impact of precipitation estimation uncertainty and physical processes on hydrologic predictive skill, and refinement of field observations and data analysis approaches as they pertain to future GPM integrated hydrologic validation and related field studies. In addition to field campaign archival of raw and processed satellite data (including precipitation products), key ground-based platforms such as the NASA NPOL S-band and D3R Ka/Ku-band dual-polarimetric radars, University of Iowa X-band dual-polarimetric radars, a large network of paired rain gauge platforms, and a large network of 2D Video and Parsivel disdrometers were deployed. In something of a canonical approach, the radar (NPOL in particular), gauge and disdrometer observational assets were deployed to create a consistent high-quality distributed (time and space sampling) radar-based ground "reference" rainfall dataset, with known uncertainties, that could be used for assessing the satellite-based precipitation products at a range of space/time scales. Subsequently, the impact of uncertainties in the satellite products could be evaluated relative to the ground-benchmark in coupled weather, land-surface and distributed hydrologic modeling frameworks as related to flood prediction. Relative to establishing the ground-based "benchmark", numerous avenues were pursued in the making and verification of IFloodS "reference" dual-polarimetric radar-based rain maps, and this study documents the process and results as they pertain specifically to efforts using the NPOL radar dataset. The initial portions of the "process" involved dual-polarimetric quality control procedures which employed standard phase and correlation-based approaches to removal of clutter and non-meteorological echo. Calculation of a scale-adaptive KDP was accomplished using the method of Wang and Chandrasekar (2009; J. Atmos. Oceanic Tech.). A dual-polarimetric blockage algorithm based on Lang et al. (2009; J. Atmos. Oceanic Tech.) was then implemented to correct radar reflectivity and differential reflectivity at low elevation angles. Next, hydrometeor identification algorithms were run to identify liquid and ice hydrometeors. After the quality control and data preparation steps were completed several different dual-polarimetric rain estimation algorithms were employed to estimate rainfall rates using rainfall scans collected approximately every two to three minutes throughout the campaign. These algorithms included a polarimetrically-tuned Z-R algorithm that adjusts for drop oscillations (via Bringi et al., 2004, J. Atmos. Oceanic Tech.), and several different hybrid polarimetric variable approaches, including one that made use of parameters tuned to IFloodS 2D Video Disdrometer measurements. Finally, a hybrid scan algorithm was designed to merge the rain rate estimates from multiple low level elevation angle scans (where blockages could not be appropriately corrected) in order to create individual low-level rain maps. Individual rain maps at each time step were subsequently accumulated over multiple time scales for comparison to gauge network data. The comparison results and overall error character depended strongly on rain event type, polarimetric estimator applied, and range from the radar. We will present the outcome of these comparisons and their impact on constructing composited "reference" rainfall maps at select time and space scales.

Radar↗

Image quality improvement in megavoltage cone beam CT using an imaging beam line and a sintered pixelated array system

Purpose: To quantify the improvement in megavoltage cone beam computed tomography (MVCBCT) image quality enabled by the combination of a 4.2 MV imaging beam line (IBL) with a carbon electron target and a detector system equipped with a novel sintered pixelated array (SPA) of translucent Gd{sub 2}O{sub 2}S ceramic scintillator. Clinical MVCBCT images are traditionally acquired with the same 6 MV treatment beam line (TBL) that is used for cancer treatment, a standard amorphous Si (a-Si) flat panel imager, and the Kodak Lanex Fast-B (LFB) scintillator. The IBL produces a greater fluence of keV-range photons than the TBL, to which the detector response is more optimal, and the SPA is a more efficient scintillator than the LFB. Methods: A prototype IBL + SPA system was installed on a Siemens Oncor linear accelerator equipped with the MVision{sup TM} image guided radiation therapy (IGRT) system. A SPA strip consisting of four neighboring tiles and measuring 40 cm by 10.96 cm in the crossplane and inplane directions, respectively, was installed in the flat panel imager. Head- and pelvis-sized phantom images were acquired at doses ranging from 3 to 60 cGy with three MVCBCT configurations: TBL + LFB, IBL + LFB, and IBL + SPA. Phantom image quality at each dose was quantified using the contrast-to-noise ratio (CNR) and modulation transfer function (MTF) metrics. Head and neck, thoracic, and pelvic (prostate) cancer patients were imaged with the three imaging system configurations at multiple doses ranging from 3 to 15 cGy. The systems were assessed qualitatively from the patient image data. Results: For head and neck and pelvis-sized phantom images, imaging doses of 3 cGy or greater, and relative electron densities of 1.09 and 1.48, the CNR average improvement factors for imaging system change of TBL + LFB to IBL + LFB, IBL + LFB to IBL + SPA, and TBL + LFB to IBL + SPA were 1.63 (p < 10{sup -8}), 1.64 (p < 10{sup -13}), 2.66 (p < 10{sup -9}), respectively. For all imaging doses, soft tissue contrast was more easily differentiated on IBL + SPA head and neck and pelvic images than TBL + LFB and IBL + LFB. IBL + SPA thoracic images were comparable to IBL + LFB images, but less noisy than TBL + LFB images at all imaging doses considered. The mean MTFs over all imaging doses were comparable, at within 3%, for all imaging system configurations for both the head- and pelvis-sized phantoms. Conclusions: Since CNR scales with the square root of imaging dose, changing from TBL + LFB to IBL + LFB and IBL + LFB to IBL + SPA reduces the imaging dose required to obtain a given CNR by factors of 0.38 and 0.37, respectively. MTFs were comparable between imaging system configurations. IBL + SPA patient image quality was always better than that of the TBL + LFB system and as good as or better than that of the IBL + LFB system, for a given dose.

61 RADIATION PROTECTION AND DOSIMETRY↗