Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “current generation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

Inter-Procedural Resource Sharing in High Level Synthesis through Function Proxies

Modular design is becoming increasingly important in High Level Synthesis (HLS) flows. Current HLS flows generate hierarchical and modular designs that mimic the structure and call graph of input specification translating functions into modules. Function calls are translated instantiating the callee module in the data-path of its caller, allowing for resource sharing when the same function is called multiple times. However, if two different callers invoke the same function, current HLS flows cannot share the instance of the module between the two callers, even if they invoke the function in a mutually exclusive way. In this paper, we propose a methodology that enables sharing of (sub)modules across modules boundaries. Sharing is obtained through function proxies, which act as forwarders of function calls in the original specification to shared modules without adding performance penalties. Building on the concept of function proxies, we propose a methodology and the related components to perform HLS of function calls through function pointers, without requiring complete static knowledge of the alias set (point-to set). We show that module sharing through function proxies provides valuable area savings without significant impacts on the execution delays, and that our synthesis approach for function pointers enables dynamic polymorphism.

HLS, function proxy, FPGA, modular HLS,↗

Effects on Freshwater Organisms of Magnetic Fields Associated with Hydrokinetic Turbines

Underwater cables will be used to transmit electricity between turbines in an array (interturbine cables), between the array and a submerged step-up transformer (if part of the design), and from the transformer or array to shore. All types of electrical transmitting cables (as well as the generator itself) will emit EMF into the surrounding water. The electric current will induce magnetic fields in the immediate vicinity, which may affect the behavior or viability of animals. Because direct electrical field emissions can be prevented by shielding and armoring, we focused our studies on the magnetic fields that are unavoidably induced by electric current moving through a generator or transmission cable. These initial experiments were carried out to evaluate whether a static magnetic field, such as would be produced by a direct current (DC) transmitting cable, would affect the behavior of common freshwater fish and invertebrates.

60 APPLIED LIFE SCIENCES↗

Performance Evaluation for Modular, Scalable Cooling Systems with Hot Aisle Containment in Data Centers

Scientific and enterprise data centers, IT equipment product development, and research data center laboratories typically require continuous cooling to control inlet air temperatures within recommended operating levels for the IT equipment. The consolidation and higher density aggregation of slim computing, storage and networking hardware has resulted in higher power density than what the raised-floor system design, coupled with commonly used computer rack air conditioning (CRAC) units, was originally conceived to handle. Many existing data centers and newly constructed data centers adopt CRAC units, which inherently handle heat transfer within data centers via air as the heat transfer media. This results in energy performance of the ventilation and cooling systems being less than optimal. Understanding the current trends toward higher power density in IT computing, more and more IT equipment manufacturers are designing their equipment to operate in 'conventional' data center environments, while considering provisions of alternative cooling solutions to either their equipment or supplemental cooling in rack or row systems. Naturally, the trend toward higher power density resulting from current and future generations of servers has, in the meanwhile, created significant opportunities for precision cooling suppliers to engineer and manufacture packaged modular and scalable systems. The modular and scalable cooling systems aim at significantly improving efficiency while addressing the thermal challenges, improving reliability, and allowing for future needs and growth. Such pre-engineered and manufactured systems may be a significant improvement over current design; however, without an energy efficiency focus, their applications could also lead to even lower energy efficiencies in the overall data center infrastructure. The overall goal of the project supported by California Energy Commission was to characterize four commercially available, modular cooling systems installed in a data center. Such modular cooling systems are all scalable localized units, and will be evaluated in terms of their operating energy efficiency in a real data center, respectively, as compared to the energy efficiency of traditional legacy data center cooling systems. The technical objective of this project was to evaluate the energy performance of one of the four commercially available modular cooling systems installed in a data center in Sun Microsystems, Inc. This report is the result of a test plan that was developed with the industrial participants input, including specific design and operating characteristics of the selected modular localized cooling solution provided by vendor 2. The technical evaluation included monitoring and measurement of selected parameters, and establishing and calculating energy efficiency metrics for the selected cooling product, which is a modular, scalable pair of chilled water cooling modules that were tested in a hot/cold aisle environment with hot aisle containment. The scope of this report is to quantify energy performance of the modular cooling unit in operation as it corresponds to a combination of varied server loads and inlet air temperatures. The information generated from this testing when combined with a concurrent research study to document the energy efficiency of the host data center's central chilled water cooling plant can be used to estimate potential energy savings from implementing modular cooling compared to conventional cooling in data centers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance Evaluation for Modular, Scalable Overhead Cooling Systems In Data Centers

Scientific and enterprise data centers, IT equipment product development, and research data center laboratories typically require continuous cooling to control inlet air temperatures within recommended operating levels for the IT equipment. The consolidation and higher density aggregation of slim computing, storage and networking hardware has resulted in higher power density than what the raised-floor system design, coupled with commonly used computer rack air conditioning (CRAC) units, was originally conceived to handle. Many existing data centers and newly constructed data centers adopt CRAC units, which inherently handle heat transfer within data centers via air as the heat transfer media. This results in energy performance of the ventilation and cooling systems being less than optimal. Understanding the current trends toward higher power density in IT computing, more and more IT equipment manufacturers are designing their equipment to operate in 'conventional' data center environments, while considering provisions of alternative cooling solutions to either their equipment or supplemental cooling in rack or row systems. Naturally, the trend toward higher power density resulting from current and future generations of servers has, in the meanwhile, created significant opportunities for precision cooling suppliers to engineer and manufacture packaged modular and scalable systems. The modular and scalable cooling systems aim at significantly improving efficiency while addressing the thermal challenges, improving reliability, and allowing for future needs and growth. Such pre-engineered and manufactured systems may be a significant improvement over current design; however, without an energy efficiency focus, their applications could also lead to even lower energy efficiencies in the overall data center infrastructure. The overall goal of the project supported by California Energy Commission was to characterize four commercially available, modular cooling systems installed in a data center. Such modular cooling systems are all scalable localized units, and will be evaluated in terms of their operating energy efficiency in a real data center, respectively, as compared to the energy efficiency of traditional legacy data center cooling systems. The technical objective of this project was to evaluate the energy performance of one of the four commercially available modular cooling systems installed in a data center in Sun Microsystems, Inc. This report is the result of a test plan that was developed with the industrial participants' input, including specific design and operating characteristics of the selected modular localized cooling solution provided by vendor 1. The technical evaluation included monitoring and measurement of selected parameters, and establishing and calculating energy efficiency metrics for the selected cooling product, which is a modular, scalable overhead cooling system. The system was tested in a hot/cold aisle environment without separation, or containment or the hot or cold aisles. The scope of this report is to quantify energy performance of the modular cooling unit in operation as it corresponds to a combination of varied server loads and inlet air temperatures. The information generated from this testing when combined with a concurrent research study to document the energy efficiency of the host data center's central chilled water cooling plant can be used to estimate potential energy savings from implementing modular cooling compared to conventional cooling in data centers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Decentralized oscillator-based converter control

A device includes a control unit that includes an oscillator circuit. The control unit is configured to generate, based on the oscillator circuit, at least one switching signal. The device also includes a direct current (DC)-to-DC conversion circuit comprising at least one electronic switch that is operatively coupled to the control unit. The DC-to-DC conversion circuit is configured to convert, based on the at least one switching signal, a DC input voltage to a DC output voltage, and the control unit is further configured to input, to the oscillator circuit, a current signal that is generated based on a measured output current of the DC-to-DC conversion circuit.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Demonstration of sub-micron UCN position resolution using room-temperature CMOS sensor

High spatial resolution of ultracold neutron (UCN) measurement is of growing interest to UCN experiments such as UCN spectrometers, UCN polarimeters, quantum physics of UCNs, and quantum gravity. Here we utilize physics informed deep learning to enhance the experimental position resolution and to demonstrate sub-micron spatial resolutions for UCN position measurements obtained using a room-temperature CMOS sensor, extending our previous work that demonstrated a position uncertainty of 1.5 microns. We explore the use of the open-source software Allpix Squared to generate experiment-like synthetic hit images with ground-truth position labels. We use physics-informed deep learning by training a fully connected neural network (FCNN) to learn a mapping from input hit images to output hit position. The automated analysis for sub-micron position resolution in UCN detection combined with the fast data rates of current and next generation UCN sources will enable improved precision for future UCN research and applications.

10B nanometer thin film↗

Non-Gaussianity, spectral index, and tensor modes in mixed inflaton and curvaton models

We study non-Gaussianity, the spectral index of primordial scalar fluctuations, and tensor modes in models where fluctuations from the inflaton and the curvaton can both contribute to the present cosmic density fluctuations. Even though simple single-field inflation models generate only tiny non-Gaussianity, if we consider such a mixed scenario, large non-Gaussianity can be produced. Furthermore, we study the inflationary parameters such as the spectral index and the tensor-to-scalar ratio in this kind of models and discuss in what cases models predict the spectral index and tensor modes allowed by the current data while generating large non-Gaussianity, which may have many implications for model-buildings of the inflationary universe.

79 ASTRONOMY AND ASTROPHYSICS↗

Rocks, water, and noble liquids: Unfolding the flavor contents of supernova neutrinos

Measuring core-collapse supernova neutrinos, both from individual supernovae within the Milky Way and from past core collapses throughout the Universe (the diffuse supernova neutrino background, or DSNB), is one of the main goals of current and next generation neutrino experiments. Detecting the heavy-lepton flavor (muon and tau types, collectively v x ) component of the flux is particularly challenging due to small statistics and large backgrounds. Further, while the next galactic neutrino burst will be observed in a plethora of neutrino channels, allowing us to measure a small number of v x events, only upper limits are anticipated for the diffuse v x flux even after decades of data taking with conventional detectors. However, paleo detectors could measure the time-integrated flux of neutrinos from galactic core-collapse supernovae via flavor-blind neutral current interactions. In this work, we show how combining a measurement of the average galactic core-collapse supernova flux with paleo detectors and measurements of the DSNB electron-type neutrino fluxes with the next-generation water Cherenkov detector Hyper-Kamiokande and the liquid noble gas detector DUNE will allow to determine the mean supernova vx flux parameters with precision of order ten percent. Realizing this potential requires both the cosmic supernova rate out to z~1 and the integrated Galactic supernova rate over the last ~1 Gyr to be established at the ~10% level.

79 ASTRONOMY AND ASTROPHYSICS↗

Density functional theory study of the influence of segregation of S or Fe impurities on electromigration in nano-grained copper interconnects

The reliability of the circuits in the modern microelectronic devices remains, during last decades, one of the key topics in research and gains an attention for improving the promising candidates for conductors. Improvement of materials for such applications can be obtained by both electronic and compositional optimization. Ab initio calculations using full potential linearized augmented plane wave method in density functional theory are applied to explain the reduction in electromigration effect in the vicinity of grain boundaries (GB) in nano-structured Cu due to the segregation of some additives to the GB. Several possible mechanisms are considered. It is demonstrated that S atoms segregated to GB of nano-structured Cu lead to the growth of effective mass of the electrons. This decreases the mobility of electrons in external electric field, and, correspondingly, the momentum that they may transfer to atoms in collisions. Fe atoms segregated to GB of Cu create new empty states at the top of the valance band. These non-occupied states may stimulate the current of holes when external electric field is applied to the system, creating the “hole wind” in the direction opposite to the current of electrons. Such “hole wind” will compensate the forces generated by the electron current and therefore will reduce the total momentum transfer between charge carriers and atoms. The calculated electron density maps show that S and Fe segregating to Cu GB increases the strength of covalent bonds reducing the diffusion of Cu atoms in the vicinity of GB.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Transmission electron microscopy characterization of electrically stressed AlGaN/GaN high electron mobility transistor devices

A set of AlGaN/GaN high electron mobility transistor devices has been investigated using step-stress testing, and representative samples of undegraded, source-side-degraded, and drain-side-degraded devices were examined using electron microscopy and microanalysis. An unstressed reference sample was also examined. All tested devices and their corresponding transmission electron microscopy samples originated from the same wafer and thus received nominally identical processing. Step-stressing was performed on each device and the corresponding current voltage characteristics were generated. Degradation in electrical performance, specifically greatly increased gate leakage current, was shown to be correlated with the presence of crystal defects near the gate edges. However, the drain-side-degraded device showed a surface pit on the source side, and another region of the same device showed no evidence of damage. Moreover, significant metal diffusion into the barrier layer from the gate contacts was also observed, as well as thin amorphous oxide layers below the gate metal contacts, even in the unstressed sample. Overall, these observations emphasize that gate-edge defects provide only a partial explanation for device failure.

Johnson, Michael↗

Neutrino resonance production at very low momentum transfer

I look back at comparisons of CC neutrino resonance interaction data at very low Q{sup 2}, from seven experiments, compared to the predictions of current neutrino event generators. When compared to data, the generator models, primarily based on the model of Rein and Sehgal, overpredict the event rate at very low Q{sup 2} for samples that are enhanced in resonance {pi}{sup +} interactions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Overland Tidal Power Generation Using Modular Tidal Prism

Naturally occurring sites with sufficient kinetic energy suitable for tidal power generation with sustained currents > 1 to 2 m/s are relatively rare. Yet sites with greater than 3 to 4 m of tidal range are relatively common around the U.S. coastline. Tidal potential does exist along the shoreline but is mostly distributed, and requires an approach which allows trapping and collection to also be conducted in a distributed manner. In this paper we examine the feasibility of generating sustainable tidal power using multiple nearshore tidal energy collection units and present the Modular Tidal Prism (MTP) basin concept. The proposed approach utilizes available tidal potential by conversion into tidal kinetic energy through cyclic expansion and drainage from shallow modular manufactured overland tidal prisms. A preliminary design and configuration of the modular tidal prism basin including inlet channel configuration and basin dimensions was developed. The unique design was shown to sustain momentum in the penstocks during flooding as well as ebbing tidal cycles. The unstructured-grid finite volume coastal ocean model (FVCOM) was used to subject the proposed design to a number of sensitivity tests and to optimize the size, shape and configuration of MTP basin for peak power generation capacity. The results show that an artificial modular basin with a reasonable footprint (≈ 300 acres) has the potential to generate 10 to 20 kw average energy through the operation of a small turbine located near the basin outlet. The potential of generating a total of 500 kw to 1 MW of power through a 20 to 40 MTP basin tidal power farms distributed along the coastline of Puget Sound, Washington, is explored.

13 HYDRO ENERGY↗

THE ORIGIN OF NET ELECTRIC CURRENTS IN SOLAR ACTIVE REGIONS

There is a recurring question in solar physics regarding whether or not electric currents are neutralized in active regions (ARs). This question was recently revisited using three-dimensional (3D) magnetohydrodynamic (MHD) numerical simulations of magnetic flux emergence into the solar atmosphere. Such simulations showed that flux emergence can generate a substantial net current in ARs. Other sources of AR currents are photospheric horizontal flows. Our aim is to determine the conditions for the occurrence of net versus neutralized currents with this second mechanism. Using 3D MHD simulations, we systematically impose line-tied, quasi-static, photospheric twisting and shearing motions to a bipolar potential magnetic field. We find that such flows: (1) produce both direct and return currents, (2) induce very weak compression currents—not observed in 2.5D—in the ambient field present in the close vicinity of the current-carrying field, and (3) can generate force-free magnetic fields with a net current. We demonstrate that neutralized currents are in general produced only in the absence of magnetic shear at the photospheric polarity inversion line—a special condition that is rarely observed. We conclude that photospheric flows, as magnetic flux emergence, can build up net currents in the solar atmosphere, in agreement with recent observations. These results thus provide support for eruption models based on pre-eruption magnetic fields that possess a net coronal current.

79 ASTRONOMY AND ASTROPHYSICS↗

Radioactive Waste Conditioning, Immobilisation, And Encapsulation Processes And Technologies: Overview And Advances (Chapter 7)

The main immobilization technologies that are available commercially and have been demonstrated to be viable are cementation, bituminization, and vitrification. Vitrification is currently the most widely used technology for the treatment of high level radioactive wastes (HLW) throughout the world. Most of the nations that have generated HLW are immobilizing in either alkali borosilicate glass or alkali aluminophosphate glass. The exact compositions of nuclear waste glasses are tailored for easy preparation and melting, avoidance of glass-in-glass phase separation, avoidance of uncontrolled crystallization, and acceptable chemical durability, e.g., leach resistance. Glass has also been used to stabilize a variety of low level wastes (LLW) and mixed (radioactive and hazardous) low level wastes (MLLW) from other sources such as fuel rod cladding/decladding processes, chemical separations, radioactive sources, radioactive mill tailings, contaminated soils, medical research applications, and other commercial processes. The sources of radioactive waste generation are captured in other chapters in this book regarding the individual practices in various countries (legacy wastes, currently generated wastes, and future waste generation). Future waste generation is primarily driven by interest in sources of clean energy and this has led to an increased interest in advanced nuclear power production. The development of advanced wasteforms is a necessary component of the new nuclear power plant (NPP) flowsheets. Therefore, advanced nuclear wasteforms are being designed for robust disposal strategies. A brief summary is given of existing and advanced wasteforms: glass, glass-ceramics, glass composite materials (GCM’s), and crystalline ceramic (mineral) wasteforms that chemically incorporate radionuclides and hazardous species atomically in their structure. Cementitious, geopolymer, bitumen, and other encapsulant wasteforms and composites that atomically bond and encapsulate wastes are also discussed. The various processing technologies are cross-referenced to the various types of wasteforms since often a particular type of wasteform can be made by a variety of different processing technologies.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Fully Solid State Thermomagnetoelectric Generator: Cycle Model and Proof-of-Concept Results

Electricity generation from heat in small-scale systems is currently limited to internal and external combustion heat engine generators or thermoelectric elements. This study introduces a new concept for a solid state thermomagnetoelectric power generator and presents a theoretical study of the cycle. While magnetocaloric materials (MCMs) are common in cryogenic cooling applications, in this work the magnetocaloric thermodynamic heat pump cycle is reversed to generate electricity from low-grade heat. A critical distinguishing feature of the approach is that there are no moving parts: the system directly converts heat into electricity with no moving magnet or regenerators (similar to thermoelectric elements). By periodic heating and cooling of the MCM, the magnetic field inside the copper coil changes in time, generating alternating current electricity. This fully solid state system can directly convert heat into electricity and is modeled at 54% of Carnot efficiency. Compared with state-of-the-art thermoelectric elements, the proposed technology has 3-4 times higher heat-to-electricity conversion efficiency at the same driving temperature difference.

Zhang, Mingkan↗

Effect of thermionic cathode heating current self-magnetic field on gaseous plasma generator characteristics

The performance capabilities of the PINK, a plasma generator with a thermionic cathode mounted in the cavity of a hollow cathode, depending for its operation on a non-self-sustained low-pressure gas discharge have been investigated. It has been shown that when a single-filament tungsten cathode 2 mm in diameter is used and the peak filament current is equal to or higher than 100 A, the self-magnetic field of the filament current significantly affects the discharge current and voltage waveforms. This effect is due to changes in the time and space distributions of the emission current density from the hot cathode. When the electron mean free path is close to the characteristic dimensions of the thermionic cathode, the synthesized plasma density distribution is nonuniform and the cathode is etched nonuniformly. The cathode lifetime in this case is 8–12 h. Using a cathode consisting of several parallel-connected tungsten filaments ∼0.8 mm in diameter moderates the effect of the self-magnetic field of the filament current and nearly doubles the cathode lifetime. The use of this type of cathode together with a discharge igniting electrode reduces the minimum operating pressure in the plasma generator to about one third of that required for the generator operation with a single-filament cathode (to 0.04 Pa)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radio-frequency stabilization of a nonequilibrium plasma accelerator

Results of experimental studies of the effect of an external RF field on the excitation of oscillations in a magnetoplasmadynamic plasma accelerator are presented. It is found that applying an RF field can suppress the drift component of low-frequency oscillations in the ejected plasma flow. The experimental data agree with the concept of stabilization of the plasma accelerator by the magnetic component of the field generated by the RF current loop. The conditions under which the RF field stabilizes the generation of the plasma flow are determined, and the factors limiting the stabilization efficiency are revealed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗