Results of the LEGEND-200 experiment in the search for $0νββ$ decay

The LEGEND experiment is looking for the extremely rare neutrinoless double beta (0νββ) decay of 76 Ge using isotopically-enriched high-purity germanium (HPGe) detectors. The detection of this process would imply that the neutrino is a Majorana particle and the total lepton number would not be conserved, which could be related to the cosmological asymmetry between matter and antimatter through leptogenesis. The long-term goal of the collaboration is LEGEND-1000: a 1-ton detector array planned to run for 10 years, with a projected half-life sensitivity exceeding 10 28 years, fully covering the inverted neutrino mass hierarchy. A first search for the 0νββ decay has been carried out by LEGEND-200 building on the experience gained from GERDA and the MAJORANA DEMONSTRATOR. The experiment has been collecting physics data for a year at the Gran Sasso National Laboratory in Italy with 140 kg of HPGe detectors. With a total exposure of 61 kg yr, LEGEND-200 has achieved a background index of $5_{−2}^{+3}$ × 10 −4 counts/(keV kg yr) in the 0νββ decay signal region from the highest performing detectors. After combining the results from GERDA, the MAJORANA Demonstrator and LEGEND-200, an exclusion sensitivity > 2.8 × 10 26 yr has been obtained at 90% confidence level for the 0νββ decay half-life, with no evidence for a signal. A new observed lower limit of $T_{1/2}^{0v} >$ 1.9 × 10 26 yr at 90% confidence level has been established.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Neutron capture reactions at DANCE

The Detector for Advanced Neutron Capture Experiments (DANCE) is a 4{pi} BaF{sub 2} array consisting of 160 active detector elements. The primary purpose of the array is to perform neutron capture cross section measurements on small (> or approx.100 {mu}g) and/or radioactive (< or approx. 100 mCi) species. The measurements made possible with this array will be useful in answering outstanding questions in the areas of national security, threat reduction, nuclear astrophysics, advanced reactor design and accelerator transmutation of waste. Since the commissioning of DANCE we have performed neutron capture cross section measurements on a wide array of medium to heavy mass nuclides. Measurements to date include neutron capture cross sections on {sup 241,243}Am, neutron capture and neutron-induced fission cross sections and capture-to-fission ratio ({alpha} = {sigma}{sub {gamma}}/{sigma}{sub f}) for {sup 235}U using a new fission-tagging detector as well as neutron capture cross sections for several astrophysics branch-point nuclei. Results from several of these measurements will be presented along with a discussion of additional physics information that can be extracted from the DANCE data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Electrochemical characterization of a low modulus Ti-35.5Nb-7.3Zr-5.7Ta alloy in a simulated body fluid using EIS for biomedical applications

Electrochemical characterization of the low modulus Ti-35.5Nb-7.3Zr-5.7Ta beta alloy (TNZT) has been performed in phosphate buffer saline solution at 37 deg. C using the non destructive electrochemical impedance spectroscopy technique. Measurements were performed at various immersion intervals at the open circuit potential (OCP), which was also monitored with time. Results obtained for TNZT alloy have been compared with those for the commercially used Ti-6Al-4V mixed alloy (Ti64) and the commercially pure titanium (Ti2) alpha alloy. Potentiodynamic polarization was performed to supplement the data obtained from EIS analysis. The TNZT alloy exhibits a two time constant impedance response, whereas the Ti64 and Ti2 alloys display a one time constant behavior. Human fetal osteoblast cells show a better adhesion and a higher cell count for the TNZT alloy compared to the other two alloys. The present investigation is an effort to understand the correlation between the electrochemical, morphological and cellular characteristics of titanium alloys to qualify them for implant applications.

36 MATERIALS SCIENCE↗

Charged particle diagnostics for inertial confinement fusion and high-energy-density physics experiments

MeV-range ions generated in inertial confinement fusion (ICF) and high-energy-density physics experiments carry a wealth of information, including fusion reaction yield, rate, and spatial emission profile; implosion areal density; electron temperature and mix; and electric and magnetic fields. Here, the principles of how this information is obtained from data and the charged particle diagnostic suite currently available at the major US ICF facilities for making the measurements are reviewed. Time-integrating instruments using image plate, radiochromic film, and/or CR-39 detectors in different configurations for ion counting, spectroscopy, or emission profile measurements are described, along with time-resolving detectors using chemical vapor deposited diamonds coupled to oscilloscopes or scintillators coupled to streak cameras for measuring the timing of ion emission. A brief description of charged-particle radiography setups for probing subject plasma experiments is also given. The goal of the paper is to provide the reader with a broad overview of available capabilities, with reference to resources where more detailed information can be found.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Principal Component Analysis of 39 Scientific Impact Measures

Background: The impact of scientific publications has traditionally been expressed in terms of citation counts. However, scientific activity has moved online over the past decade. To better capture scientific impact in the digital era, a variety of new impact measures has been proposed on the basis of social network analysis and usage log data. Here we investigate how these new measures relate to each other, and how accurately and completely they express scientific impact. Methodology: We performed a principal component analysis of the rankings produced by 39 existing and proposed measures of scholarly impact that were calculated on the basis of both citation and usage log data. Conclusions: Our results indicate that the notion of scientific impact is a multi-dimensional construct that can not be adequately measured by any single indicator, although some measures are more suitable than others. The commonly used citation Impact Factor is not positioned at the core of this construct, but at its periphery, and should thus be used with caution.

59 BASIC BIOLOGICAL SCIENCES↗

Supporting data for "Frozen flume experiments indicate rapid permafrost riverbank erosion depends on bank roughness"

This dataset contains supporting files detailing five frozen flume experiments conducted at the Caltech Earth Surface Dynamics Laboratory to investigate rates of ablation-limited permafrost riverbank erosion under controlled conditions. Water flowed past a bank of saturated, frozen sand and ice and gradually eroded the bank by thawing pore ice and immediately entraining sand and washing it downstream. Experiments were scaled for flow hydraulics and heat transfer allowing comparisons between our results and natural permafrost riverbanks. For each experiment, we measured the initial and final sand bank topography using a Keyence laser scanner, water surface slope at 3-min intervals throughout the experiment using a Massa sonar scanner, bank erosion using 10-sec overhead timelapse imagery taken by an overhead camera, water and bank temperature using thermistors frozen into the sand bank and sampling at 2 Hz, and water discharge using an in-line flow meter. We include calibration data for the carriage (engineered by the Saint Anthony Falls Laboratory) used to make sonar and laser topography measurements. We also include calibration data for temperature sensors, water discharge measurements, and images of a regular grid placed in the flume to align overhead camera images with the carriage datum. Grain size analysis for the channel bed (gravel) was produced using a pebble count and bank sand was measured using a Camsizer X2. In addition to the five frozen experiments, we include sonar scans of water surface slope and Keyence scans of bed and bank topography for calibration experiments ran with an immobile gravel bank and bed.

54 ENVIRONMENTAL SCIENCES↗

Short papers on current state of sequencing, metagenomics, and RNAseq for diagnostics

This report contains three papers on the current state of sequencing, metagenomics, and RNAseq for diagnostics. 1) There are many factors that must be evaluated before ascertaining what type of technology is most cost effective, and/or most technically effective. In general, long read technologies are primarily used for in field/in situ sequencing and for closing isolate genomes, while short read sequencing lends itself to rapid high quality determination of strain identity and to applications that require high depth, such as metagenomes and counting applications, like in RNAseq. 2) RNAseq can provide some important insights into the biology of active infections and provide advances in diagnostics approaches. Depth of sequencing coverage is critical to determine gene expression profiles. Full use of RNAseq data from both host and pathogen(s) for diagnostics and informed treatment options will require further investigation. 3) RNAseq can provide some important insights into the biology of active infections and provide advances in diagnostics approaches. Depth of sequencing coverage is critical to determine gene expression profiles. Full use of RNAseq data from both host and pathogen(s) for diagnostics and informed treatment options will require further investigation.

59 BASIC BIOLOGICAL SCIENCES↗

Dynamical Models for the Sculptor Dwarf Spheroidal in a ΛCDM Universe

The Sculptor dwarf spheroidal galaxy appears to contain two distinct stellar populations of differing metallicity. Several authors have argued that in order for these two populations to reside in the same gravitational potential, the dark matter halo must have a core similar to that observed in the stellar count profile. This would exclude cuspy Navarro–Frenk–White (NFW) density profiles of the kind predicted for halos and subhalos by dark matter-only simulations of the ΛCDM cosmological model. We present a new theoretical framework to analyze observations of stellar count and velocity in a self-consistent manner based on separable models, f(E,J)=g(J)h(E), for the distribution function of an equilibrium spherical system. We use this machinery to analyze available photometric and kinematic data for the two stellar populations in Sculptor. We find, contrary to some previous claims, that the data are consistent with populations in equilibrium within an NFW dark matter potential with structural parameters in the range expected in ΛCDM; we find no statistical preference for a potential with a core. Our models allow a maximum circular velocity for Sculptor between 20 and 35 km s{sup −1}. We discuss why some previous authors came to a different conclusion.

79 ASTRONOMY AND ASTROPHYSICS↗

Fissile material holdup measurement systems: an historical review of hardware and software

The measurement of fissile material holdup is accomplished by passively measuring the energy-dependent photon flux and/or passive neutron flux emitted from the fissile material deposited within an engineered process system. Both measurement modalities--photon and neutron--require the implementation of portable, battery-operated systems that are transported, by hand, from one measurement location to another. Because of this portability requirement, gamma-ray spectrometers are typically limited to inorganic scintillators, coupled to photomultiplier tubes, a small multi-channel analyzer, and a handheld computer for data logging. For neutron detection, polyethylene-moderated, cadmium-back-shielded He-3 thermal neutron detectors are used, coupled to nuclear electronics for supplying high voltage to the detector, and amplifying the signal chain to the scaler for counting. Holdup measurement methods, including the concept of Generalized Geometry Holdup (GGH), are well presented by T. Douglas Reilly in LA-UR-07-5149 and P. Russo in LA-14206, yet both publications leave much of the evolutionary hardware and software to the imagination of the reader. This paper presents an historical review of systems that have been developed and implemented since the mid-1980s for the nondestructive assay of fissile material, in situ. Specifications for the next-generation holdup measurements systems are conjectured.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Classification Analytics of Pu-239 and U-235 Source Signatures Using Gamma Spectral Regions

Machine learning detection methods using gamma signatures from spectral measurements of low-intensity Pu-239 and U-235 sources are studied. NaI detectors located at different distances fromthe source have been used to collect the training and independent testing data sets. The source is introduced via a shielded conduit into the facility where it is surrounded by 21 NaI detectors deployed over 6 x 6 meters area in the formation of two concentric circles and a spiral. The counts in gamma spectral regions associated with these two sources are estimated at 1 second intervals for each NaI detector, and are used as classifier features for detecting the source presence. Eight different classifiers with five basic properties — namely, smooth, non-smooth, statistical, structural, and hyper-parameter tuning — are trained and tested using the background and source measurements collected over multiple experimental runs. While the overall classifier performance improved as detectors closer to the source are used, some identically produced detectors under-performed but differently between two sources. Some classifiers achieved lower training error but their testing error based on independent measurements is higher for both sources. Overall, these results indicate significant over-fitting by these methods, and illustrate the complexity of training and selecting the machine learning methods to solve these detection problems.

Rao, Nageswara↗

Remote Radiation Sensing Using Aerial and Ground Platforms

Remote sensing of ionizing radiation has a significant role in waste management, nuclear material management and nonproliferation, and radiation safety. Robotic platforms can surpass the number of tasks that are achieved by humans. With this technique, the operator's radiation exposure can be decreased. Remote sensing allows for the evaluation and monitoring of radiological contamination. Gamma-ray and neutron sensors were integrated onto the robotic platforms. This approach allows for the radiation sensor data to be dynamically tracked and mapped thus enabling further analysis of the radiation flux in temporal and spatial domains. The goal is to complete scheduled tasks while the robot is being irradiated. To achieve this, electronic components must be shielded and radiation hardened. CZT Detector: Cadmium Zinc Telluride (CZT) detector technology has been a promising solution for gamma-ray and x-ray measurements. Detector data is transferred to the Odroid minicomputer that controls and powers the module via the USB. Robot Operating System (ROS) was utilized for data acquisition and data fusion. The Mariscotti method was employed for the spectrum analysis. A function was programmed in ROS for the automatic identification of photopeaks. CLYC Detector: A Cs{sub 2}LiYCl{sub 6}:Ce{sup 3+} (CLYC) detector was used for simultaneous medium-resolution gamma-ray measurements and neutron counting. A 2.54 cm diameter photomultiplier tube (PMT) was equipped with a high voltage supply and a miniature digitizer. Gamma-ray excitation: fast core-to-valence luminescence (CVL) with 1 ns decay constant, and prompt Ce{sup 3+} emission with 50 ns decay constant. Neutron excitation: slow cerium self-trapped excitation (Ce{sup 3+} STE), 1000 ns decay constant. Radiation Source Localization: Maximum Likelihood Estimation (MLE) and gradient-based methods were used to locate the position of a radiation source based on measured radiation intensities. Multi-Particle Transport Code FLUKA: Estimation of radiation damage of the electronic components is important in order to optimize the robot's operational time while it is irradiated. Displacement per atom (DPA) represents the radiation damage in materials exposed to the ionizing radiation. Various shielding layers of different thickness t were analyzed (< 5% statistical error). The model of the controller of the UAS was designed in FLUKA. Conclusion: CZT and CLYC detectors were integrated onto the robotic platforms. Radiation source localization and contour mapping using robotic platforms were studied. Functions for data analysis and fusion were developed in ROS. FLUKA code was utilized to analyze DPA values. Layers of low-density and high-density materials were used to shield the UAS electronics.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Arctic Impact Identification with Less Data Using Variable Relationships: An Exploratory Express LDRD project.

Regional impacts from sea ice loss can be challenging to separate from internal climate variability, potentially requiring thousands of ensemble members. East Asian wintertime cooling has been linked to sea ice loss from present day conditions in the Polar Amplification Model Intercomparison Project with these large ensemble counts. This cooling is theorized to arise from a strengthened Siberian High and East Asian Jet response. The strengthened Siberian High can be detected with one fifth the ensemble members needed for the East Asian wintertime cooling in a single model. We thus hypothesize that leveraging relationships between multiple variables in a conditional pathways-based approach would reduce the number of required ensemble members to conclusively attribute East Asian wintertime cooling to future sea ice concentrations. In all analyzed cases, confidence was increased when evaluating sea ice loss’s responsibility for the joint effects of East Asian cooling, East Asian Jet strengthening, and Siberian High strengthening over just East Asian cooling. However, we were not able to confidently attribute future East Asian wintertime cooling to sea ice loss in a single model. We found that significant intra-ensemble variability within single Earth System Models (ESMs) produced highly uncertain forcing response models upon which attribution results were undermined. We were able to show that ensemble mean seasonally averaged metrics from multiple ESMs greatly improved the accuracy of the forcing response linear models and exposed the necessity of all three steps in the pathway (sea ice area, Siberian High pressure, and East Asian Jet speed) for accurate prediction of East Asian wintertime cooling. Although all three steps were necessary, East Asian wintertime cooling possesses a large dependence on the Siberian High pressure, which weakens the confidence associated with overall strong joint-attribution comparing present day and future scenarios. We believe transitioning the pathway nodes to relative changes between the Siberian High and Aleutian Low as well as between the midlatitude westerlies and subtropical jet in the East Asianj Jet region may be able to produce significant attribution more fully dependent upon all three steps. Ultimately, this research demonstrates the simple extensibility of conditional pathways-based attribution to sea ice loss forcing on the Earth system.

54 ENVIRONMENTAL SCIENCES↗

Observing fish interactions with marine energy turbines using acoustic cameras

Abstract Marine current energy converters such as tidal and riverine turbines have the potential to provide reliable, clean power. The risk of collision of fishes with marine energy turbines is not yet well understood, in part due to the challenges associated with observing fish at turbine sites. Turbidity and light availability can limit the effectiveness of optical sensors like video cameras, motivating the use of acoustic cameras for this task. However, challenges persist in collecting and interpreting data acquired from acoustic cameras. Given the limited number of turbine deployments to date, it is prudent to draw on the application of acoustic cameras to monitor fish in other scenarios. This article synthesizes their use for other fisheries applications to inform best practices and set realistic expectations for the results of acoustic camera monitoring at turbine sites. We discuss six key tasks performed with acoustic cameras: detecting objects, identifying objects as fish, counting fish, measuring fish, classifying fish taxonomically and analysing fish behavior. Specific challenges to monitoring fish at turbine sites are discussed. This article is intended to serve as a reference for researchers, regulators and marine energy developers on effective use of acoustic cameras to monitor fish at turbine sites. The studies detailed in this article provide evidence that, in some scenarios, acoustic cameras can be used to inform the risk of fish collision with marine energy turbines but doing so requires careful study design and data processing.

Cotter, Emma↗

Method for system-independent material characterization from spectral X-ray CT

We propose a method for material characterization using Spectral X-ray Computed Tomography (SCT). Our SCT method takes advantage of recently-developed MultiX ME 100 photon counting detectors to simultaneously measure the energy dependence of a material's linear attenuation coefficient (LAC). Relative electron density (ρ e ) and effective atomic number (Z e ) are estimated directly from the energy-dependent LAC measurements. The method employs a spectral correction algorithm and automated selection and weighting of the energy bins for optimized performance. When examining materials with Z e ≤ 23, this method achieves accuracy comparable to traditional dual-energy CT, which is often realized through consecutive data acquisitions, and is compatible with any spectral detector. The method disregards data in photon starved energy channels improving the detection of highly attenuating materials, compared to techniques that use energy integrating detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Buzzard Flock: Dark Energy Survey Synthetic Sky Catalogs

We present a suite of 18 synthetic sky catalogs designed to support science analysis of galaxies in the Dark Energy Survey Year 1 (DES Y1) data. For each catalog, we use a computationally efficient empirical approach, ADDGALS, to embed galaxies within light-cone outputs of three dark matter simulations that resolve halos with masses above ~5x10^12 h^-1 m_sun at z <= 0.32 and 10^13 h^-1 m_sun at z~2. The embedding method is tuned to match the observed evolution of galaxy counts at different luminosities as well as the spatial clustering of the galaxy population. Galaxies are lensed by matter along the line of sight --- including magnification, shear, and multiple images --- using CALCLENS, an algorithm that calculates shear with 0.42 arcmin resolution at galaxy positions in the full catalog. The catalogs presented here, each with the same LCDM cosmology (denoted Buzzard), contain on average 820 million galaxies over an area of 1120 square degrees with positions, magnitudes, shapes, photometric errors, and photometric redshift estimates. We show that the weak-lensing shear catalog, redMaGiC galaxy catalogs and redMaPPer cluster catalogs provide plausible realizations of the same catalogs in the DES Y1 data by comparing their magnitude, color and redshift distributions, angular clustering, and mass-observable relations, making them useful for testing analyses that use these samples. We make public the galaxy samples appropriate for the DES Y1 data, as well as the data vectors used for cosmology analyses on these simulations.

79 ASTRONOMY AND ASTROPHYSICS↗

Redox and volatility of Tc(CO)3 + compounds in waste glass melting

The behavior of non-pertechnetate (Tc(I)) species was studied by preparing three portions of dried low-activity waste-glass simulated feed, combining it with either the [fac-Tc(CO) (OH)] “tetramer,” the [fac-Tc(CO) (OH)(H O) ] “monohydroxo,” or the [fac-Tc(CO) Cl ] “trichloro,” and then heating samples to 600, 800, and 1000 °C. For the feeds and the heat-treated samples, Tc concentrations were measured by liquid scintillation counting (LSC) after NaOH and HNO fusion, and the results were used to determine the Tc volatility. For unheated samples and samples heated to 600 °C, the speciation of Tc was measured by X-ray absorption near-edge structure (XANES) analysis, while partitioning of Tc in the glass-forming melt was determined by leaching the samples in water and measuring the Tc concentration of the leachate. The current results are discussed in connection with previously reported data for Tc(VII) and Tc(IV) species to rationalize the potential mechanism on how different speciation of Tc affect its retention in glass. 3 4 3 2 2 3 3 3 2-

Luksic, SA↗

Impact of Bone Marrow Radiation Dose on Acute Hematologic Toxicity in Cervical Cancer: Principal Component Analysis on High Dimensional Data

Purpose: To study the effects of increasing pelvic bone marrow (BM) radiation dose on acute hematologic toxicity in patients undergoing chemoradiotherapy, using a novel modeling approach to preserve the local spatial dose information. Methods and Materials: The study included 37 cervical cancer patients treated with concurrent weekly cisplatin and pelvic radiation therapy. The white blood cell count nadir during treatment was used as the indicator for acute hematologic toxicity. Pelvic BM radiation dose distributions were standardized across patients by registering the pelvic BM volumes to a common template, followed by dose remapping using deformable image registration, resulting in a dose array. Principal component (PC) analysis was applied to the dose array, and the significant eigenvectors were identified by linear regression on the PCs. The coefficients for PC regression and significant eigenvectors were represented in three dimensions to identify critical BM subregions where dose accumulation is associated with hematologic toxicity. Results: We identified five PCs associated with acute hematologic toxicity. PC analysis regression modeling explained a high proportion of the variation in acute hematologicity (adjusted R{sup 2}, 0.49). Three-dimensional rendering of a linear combination of the significant eigenvectors revealed patterns consistent with anatomical distributions of hematopoietically active BM. Conclusions: We have developed a novel approach that preserves spatial dose information to model effects of radiation dose on toxicity, which may be useful in optimizing radiation techniques to avoid critical subregions of normal tissues. Further validation of this approach in a large cohort is ongoing.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterization of partially observed epidemics through Bayesian inference: application to COVID-19

We demonstrate a Bayesian method for the "real-time'" characterization and forecasting of partially observed COVID-19 epidemic. Characterization is the estimation of infection spread parameters using daily counts of symptomatic patients.The method is designed to help guide medical resource allocation in the early epoch of the outbreak. The estimation problem is posed as one of Bayesian inference and solved using a Markov chain Monte Carlo technique. The data used in this study was sourced before the arrival of the second wave of infection in July 2020. The proposed modeling approach, when applied at the country level, generally provides accurate forecasts at the regional, state and country level. The epidemiological model detected the flattening of the curve in California, after public health measures were instituted.The method also detected different disease dynamics when applied to specific region of New Mexico