Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “column”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

An Improved Retrieval of Tropospheric Nitrogen Dioxide from GOME

We present a retrieval of tropospheric nitrogen dioxide (NO2) columns from the Global Ozone Monitoring Experiment (GOME) satellite instrument that improves in several ways over previous retrievals, especially in the accounting of Rayleigh and cloud scattering. Slant columns, which are directly fitted without low-pass filtering or spectral smoothing, are corrected for an artificial offset likely induced by spectral structure on the diffuser plate of the GOME instrument. The stratospheric column is determined from NO2 columns over the remote Pacific Ocean to minimize contamination from tropospheric NO2. The air mass factor (AMF) used to convert slant columns to vertical columns is calculated from the integral of the relative vertical NO2 distribution from a global 3-D model of tropospheric chemistry driven by assimilated meteorological data (Global Earth Observing System (GEOS)-CHEM), weighted by altitude dependent scattering weights computed with a radiative transfer model (Linearized Discrete Ordinate Radiative Transfer), using local surface albedos determined from GOME observations at NO2 wavelengths. The AMF calculation accounts for cloud scattering using cloud fraction, cloud top pressure, and cloud optical thickness from a cloud retrieval algorithm (GOME Cloud Retrieval Algorithm). Over continental regions with high surface emissions, clouds decrease the AMT by 20- 30% relative to clear sky. GOME is almost twice as sensitive to tropospheric NO2 columns over ocean than over land. Comparison of the retrieved tropospheric NO2 columns for July 1996 with GEOS-CHEM values tests both the retrieval and the nitrogen oxide radical (NOx) emissions inventories used in GEOS-CHEM. Retrieved tropospheric NO2 columns over the United States, where NOx emissions are particularly well known, are within 18% of GEOS-CHEM columns and are strongly spatially correlated (r = 0.78, n = 288, p less than 0.005). Retrieved columns show more NO2 than GEOS-CHEM columns over the Transvaal region of South Africa and industrial regions of the northeast United States and Europe. They are lower over Houston, India, eastern Asia, and the biomass burning region of central Africa, possibly because of biases from absorbing aerosols.

Martin, Randall V.↗

Migration and Distribution of Natural Organic Matter Injected into Subsurface Systems - 16523

The Savannah River Site (SRS) was one of the major U.S. Department of Energy facilities that produced large amounts of radioactive and hazardous waste during the Cold War era, a legacy of material production for defense purposes. The unlined F-Area seepage basins received approximately 1.8 billion gallons of acidic waste solutions containing low-level radioactivity from numerous isotopes generated by uranium slug and irradiated fuel processing. Sufficient quantities of uranium isotopes, I-129, Tc-99, and tritium migrated into the groundwater, creating an acidic plume with a pH between 3 and 5.5. Humic substances (HS) are complex heterogeneous mixtures of poly-dispersed materials formed by biochemical and chemical reactions during the decay and transformation of plant and microbial remains. They are known for their excellent binding capacity for metals, making them a strong candidate for remediation efforts to reduce the mobility of uranium (VI) in the subsurface. Studies showed that HS are an important ion exchange and metal-complexing ligand, carrying a large number of functional groups with high complexing capacity that can greatly affect the mobility behavior of actinides in natural systems. Hence, it is a potential in situ amendment for treating groundwater contaminated with these constituents. Column experiments were conducted to address the complexities of HS in flow-through porous media representative of the acidic aquifer at the SRS F-Area Seepage Basins. The humate source used, Huma-K, is high in humic and fulvic compounds. The column studies were done using the soil obtained from SRS's FAW-1 core-hole at a depth interval of 60'-70'. A bromide tracer test was performed to obtain the pore volume (PV), variance and Peclet number. The columns were saturated with an artificial groundwater solution prepared to mimic the groundwater at SRS that was pH adjusted to 3.5 and 5 until the effluent pH reached equilibrium. Approximately one (1) PV of 5000 ppm of Huma-K was injected into the columns at 2 ml/min to study the sorption of Huma-K on the sediment. Desorption of Huma-K was studied by injecting approximately four (4) PVs of the pH adjusted artificial groundwater solution. A faster increase in pH was observed in column 1 (saturated with pH 3.5 AGW) compared to column 2 (saturated with pH 5 AGW). After injection of 2 PV of AGW, the pH of the columns reached 6.5 and 7, respectively, for columns 1 and 2. After injecting an additional PV of AGW, the pH remained relatively stable. With an increase in pH from 3.5 to 5.0, the overall retention of HA increased from 461 mg/kg for the column with pH 3.5 to 642 mg/kg for the column with pH 5. This suggests that retention is not due to adsorption alone, but adsorption coupled with precipitation and re-dissolution of Huma-K as it flows through the columns is a possible explanation for greater retention at pH 5. This negates the use of a simple Langmuir isotherm to explain humate behavior in the acidic environment of column 1. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

HarDWR - Harmonized Water Rights Records

A dataset within the Harmonized Database of Western U.S. Water Rights (HarDWR). For a detailed description of the database, please see the meta-record v2.0. Changelog v2.0 - Recalculated based on data sourced from WestDAAT - Changed using a Site ID column to identify unique records to using aa combination of Site ID and Allocation ID - Removed the Water Management Area (WMA) column from the harmonized records. The replacement is a separate file which stores the relationship between allocations and WMAs. This allows for allocations to contribute to water right amounts to multiple WMAs during the subsequent cumulative process. - Added a column describing a water rights legal status - Added "Unspecified" was a water source category - Added an acre-foot (AF) column - Added a column for the classification of the right's owner v1.02 - Added a .RData file to the dataset as a convenience for anyone exploring our code. This is an internal file, and the one referenced in analysis scripts as the data objects are already in R data objects. v1.01 - Updated the names of each file with an ID number less than 3 digits to include leading 0s v1.0 - Initial public release Description Here we present an updated database of Western U.S. water right records. This database provides consistent unique identifiers for each water right record, and a consistent categorization scheme that puts each water right record into one of seven broad use categories. These data were instrumental in conducting a study of the multi-sector dynamics of inter-sectoral water allocation changes though water markets (Grogan et al., *in review*). Specifically, the data were formatted for use as input to a process-based hydrologic model, Water Balance Model (WBM), with a water rights module (Grogan et al., *in review*). While this specific study motivated the development of the database presented here, water management in the U.S. West is a rich area of study (e.g., Anderson and Woosly, 2005; Tidwell, 2014; Null and Prudencio, 2016; Carney et al., 2021) so releasing this database publicly with documentation and usage notes will enable other researchers to do further work on water management in the U.S. West. We produced the water rights database presented here in four main steps: (1) data collection, (2) data quality control, (3) data harmonization, and (4) generation of cumulative water rights curves. Each of steps (1)-(3) had to be completed in order to produce (4), the final product that was used in the modeling exercise in Grogan et al. (*in review*). All data in each step is associated with a spatial unit called a Water Management Area (WMA), which is the unit of water right administration utilized by the state in which the right came from. Steps (2) and (3) required use to make assumptions and interpretation, and to remove records from the raw data collection. We describe each of these assumptions and interpretations below so that other researchers can choose to implement alternative assumptions an interpretation as fits their research aims. Motivation for Changing Data Sources The most significant change has been a switch from collecting the raw water rights directly from each state to using the water rights records presented in WestDAAT, a product of the Water Data Exchange (WaDE) Program under the Western States Water Council (WSWC). One of the main reasons for this is that each state of interest is a member of the WSWC, meaning that WaDE is partially funded by these states, as well as many universities. As WestDAAT is also a database with consistent categorization, it has allowed us to spend less time on data collection and quality control and more time on answering research questions. This has included records from water right sources we had previously not known about when creating v1.0 of this database. The only major downside to utilizing the WestDAAT records as our raw data is that further updates are tied to when WestDAAT is updated, as some states update their public water right records daily. However, as our focus is on cumulative water amounts at the regional scale, it is unlikely most records updates would have a significant effect on our results. The structure of WestDAAT led to several important changes to how HarWR is formatted. The most significant change is that WaDE has calculated a field known as `SiteUUID`, which is a unique identifier for the Point of Diversion (POD), or where the water is drawn from. This separate from `AllocationNativeID`, which is the identifier for the allocation of water, or the amount of water associated with the water right. It should be noted that it is possible for a single site to have multiple allocations associated with it and for an allocation to be able to be extracted from multiple sites. The site-allocation structure has allowed us to adapt a more consistent, and hopefully more realistic, approach in organizing the water right records than we had with HarDWR v1.0. This was incredibly helpful as the raw data from many states had multiple water uses within a single field within a single row of their raw data, and it was not always clear if the first water use was the most important, or simply first alphabetically. WestDAAT has already addressed this data quality issue. Furthermore, with v1.0, when there were multiple records with the same water right ID, we selected the largest volume or flow amount and disregarded the rest. As WestDAAT was already a common structure for disparate data formats, we were better able to identify sites with multiple allocations and, perhaps more importantly, allocations with multiple sites. This is particularly helpful when an allocation has sites which cross WMA boundaries, instead of just assigning the full water amount to a single WMA we are now able to divide the amount of water between the number of relevant WMAs. As it is now possible to identify allocations with water used in multiple WMAs, it is no longer practical to store this information within a single column. Instead the stAllocationToWMATab.csv file was created, which is an allocation by WMA matrix containing the percent Place of Use area overlap with each WMA. We then use this percentage to divide the allocation's flow amount between the given WMAs during the cumulation process to hopefully provide more realistic totals of water use in each area. However, not every state provides areas of water use, so like HarDWR v1.0, a hierarchical decision tree was used to assign each allocation to a WMA. First, if a WMA could be identified based on the allocation ID, then that WMA was used; typically, when available, this applied to the entire state and no further steps were needed. Second was the spatial analysis of Place of Use to WMAs. Third was a spatial analysis of the POD locations to WMAs, with the assumption that allocation's POD is within the WMA it should belong to; if an allocation still had multiple WMAs based on its POD locations, then the allocation's flow amount would be divided equally between all WMAs. The fourth, and final, process was to include water allocations which spatially fell outside of the state WMA boundaries. This could be due to several reasons, such as coordinate errors / imprecision in the POD location, imprecision in the WMA boundaries, or rights attached with features, such as a reservoir, which crosses state boundaries. To include these records, we decided for any POD which was within one kilometer of the state's edge would be assigned to the nearest WMA. Other Changes WestDAAT has Allowed In addition to a more nuanced and consistent method of assigning water right's data to WMAs, there are other benefits gained from using the WestDAAT dataset. Among those is a consistent categorization of a water right's legal status. In HarDWR v1.0, legal status was effectively ignored, which led to many valid concerns about the quality of the database related to the amounts of water the rights allowed to be claimed. The main issue was that rights with legal status' such as "application withdrawn", "non-active", or "cancelled" were included within HarDWR v1.0. These, and other water rights status' which were deemed to not be in use have been removed from this version of the database. Another major change has been the addition of the "unspecified water source category. This is water that can come from either surface water or groundwater, or the source of which is unknown. The addition of this source category brings the total number of categories to three. Due to reviewer feedback, we decided to add the acre-foot (AF) column so that the data may be more applicable to a wider audience. We added the ownerClassification column so that the data may be more applicable to a wider audience. File Descriptions The dataset is a series of various files organized by state sub-directories. In addition, each file begins with the state's name, in case the file is separate from its sub-directory for some reason. After the state name is the text which describes the contents of the file. Here is each file described in detail. Note that st is a placeholder for the state's name. stFullRecords_HarmonizedRights.csv: A file of the complete water records for each state. The column headers for each of this type of file are: state - The name of the state to which the allocations belong to. FIPS - The two digit numeric state ID code. siteID - The site location ID for POD locations. A site may have multiple allocations, which are the actual amount of water which can be drawn. In a simplified hypothetical, a farm stead may have an allocation for "irrigation" and an allocation for "domestic" water use, but the water is drawn from the same pumping equipment. It should be noted that many of the site ID appear to have been added by WaDE, and therefore may not be recognized by a given state's water rights database. allocationID - The allocation ID for the water right. For most states this is the water right ID, and what is recommended to use should a right be looked up on a given state's water rights database. The water amounts associated with these IDs tend to be finer scaled than those associated with siteID. It should be noted that some allocations may be extracted from multiple sites, particularly for larger Places of Use. ownerClassification - A classification of the types of owners for water rights. The most common is `Private` which incorporates a wide range of entities. Several classifications would be grouped into a government category, most of which are for the U.S. Federal Government. These allocations could be listed as "Federal", "United States of America", or as the names of any number of federal agencies. The last major grouping of entities is for "Native American"s. priorityDate - The date we use as the water right priority date for our modeling analysis. This is the legal priority date when it is available. However, for some rights, specifically from California and New Mexico, we used a pseudo priority date (e.g. well completion date or start of well drilling date) when a legal priority date was not available. The most questionable dates come from New Mexico, where the only date associated with certain water right records was the date the allocation was recorded in the database. As the allocation record creation tended to be within a few months of the filing of the application of the water right, from manually double checking the water rights, and our analysis focuses on aggregating water rights on the timescale of years, we determined it was acceptable to use such dates to include as many records as possible. primaryBeneficialUse - From the numerous state water use categories, WaDE categorized them into 21 categories WestDAAT. This column is the original WaDE category for the primary water use at the PoD site. allocationBeneficialUse - From the numerous state water use categories, WaDE categorized them into 21 categories for WestDAAT. This column is the original WaDE category

Economics↗

Hydraulic Permeability of Resorcinol-Formaldehyde Ion-Exchange Resin - Effects of Oxygen Uptake and Radiation

An ion-exchange process, using spherical resorcinol-formaldehyde (RF) resin is the baseline process for removing cesium from the dissolved salt solution in the high-level waste tanks at the U.S. Department of Energy's (DOE) Hanford site in Washington State. The RF resin is also being evaluated for use in the proposed Small Column Ion Exchange (SCIX) system, which is an alternative treatment option at DOE's Savannah River Site (SRS)in South Carolina. Testing at ORNL will determine the impact of radiation exposure and oxygen uptake by the RF resin on the hydraulic permeability of the resin. Samples of the resin will be removed periodically to measure physical properties (bead size and compressibility) and cesium capacity. The proposed full-scale treatment system at Hanford, the Waste Treatment Plant (WTP), will use an ion-exchange column containing nominally 680 gal of resin, which will treat 30 gpm of waste solution. The ion-exchange column is designed for a typical pressure drop of 6 psig, with a maximum of 9.7 psig. The lab-scale column is 3-in. clear PVC pipe and is prototypic of the proposed Hanford column. The fluid velocity in the lab-scale test will be much higher than for the full-scale column, in order to generate the maximum pressure drop expected in that column (9.7 psig). The frictional drag from this high velocity will produce similar forces on the resin in the lab-scale column as would be expected at the bottom of the full-scale column. The chemical changes in the resin caused by radiation exposure and oxygen uptake are expected to cause physical changes in the resin that could reduce the bed porosity and reduce the hydraulic permeability of the resin bed. These changes will be monitored by measuring the pressure drop through the lab-scale column and by measuring the physical properties of samples of the resin. The test loop with the lab-scale column is currently being fabricated, and operation will start by late May. Testing will be completed by the end of August.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Carbon Dioxide Sealing Capacity: Textural or Compositional Controls? (Final Scientific/Technical Report)

This research project is aiming to assess the carbon dioxide sealing capacity of most common seal-rocks, such as shales and non-fractured limestones, by analyzing the role of textural and compositional parameters of those rocks. We hypothesize that sealing capacity is controlled by textural and/or compositional parameters of caprocks. In this research, we seek to evaluate the importance of textural and compositional parameters affecting the sealing capacity of caprocks. The conceptual framework involves two testable end-member hypotheses concerning the sealing capacity of carbon dioxide reservoir caprocks. Better understanding of the elements controlling sealing quality will advance our knowledge regarding the sealing capacity of shales and carbonates. Due to relatively low permeability, shale and non-fractured carbonate units are considered relatively impermeable formations which can retard reservoir fluid flow by forming high capillary pressure. Similarly, these unites can constitute reliable seals for carbon dioxide capture and sequestration purposes. This project is a part of the comprehensive project with the final aim of studying the caprock sealing properties and the relationship between microscopic and macroscopic characteristics of seal rocks in depleted gas fields of Oklahoma Panhandle. Through this study we examined various seal rock characteristics to infer about their respective effects on sealing capacity in special case of replacing reservoir fluid with super critical carbon dioxide (scCO 2 ). To assess the effect of textural and compositional properties on scCO 2 maximum retention column height we collected 30 representative core samples in caprock formations in three counties (Cimarron, Texas, Beaver) in Oklahoma Panhandle. Core samples were collected from various seal formations (e.g., Cherokee, Keys, Morrowan) at different depths. We studied the compositional and textural properties of the core samples using several techniques. Mercury Injection Porosimetry (MIP), Scanning Electron Microscopy SEM, and Sedigraph measurements are used to assess the pore-throat-size distribution, sorting, texture, and grain size of the samples. Also, displacement pressure at 10% mercury saturation (Pd) and graphically derived threshold pressure (P c ) were determined by MIP technique. SEM images were used for qualitative study of the minerals and pores texture of the core samples. Moreover, EDS (Energy Dispersive X-Ray Spectrometer), BET specific surface area, and Total Organic Carbon (TOC) measurements were performed to study various parameters and their possible effects on sealing capacity of the samples. We found that shales have the relatively higher average sealing threshold pressure (P c ) than carbonate and sandstone samples. Based on these observations, shale formations could be considered as a promising caprock in terms of retarding scCO 2 flow and leakage into above formations. We hypothesized that certain characteristics of shales (e.g., 3 fine pore size, pore size distribution, high specific surface area, and strong physical chemical interaction between wetting phase and mineral surface) make them an efficient caprock for sealing super critical CO 2 . We found that the displacement pressure at 10% mercury saturation could not be the ultimate representative of the sealing capacity of the rock sample. On the other hand, we believe that graphical method, introduced by Cranganu (2004) is a better indicator of the true sealing capacity. Based on statistical analysis of our samples from Oklahoma Panhandle we assessed the effects of each group of properties (textural and compositional) on maximum supercritical CO 2 height that can be hold by the caprock. We conclude that there is a relatively strong positive relationship (+.40 to +.69) between supercritical CO 2 column height based on P c and hard/ soft mineral content index (ratio of minerals with Mohs hardness more than 5 over minerals with Mohs hardness less than 5) in both shales and limestone samples. Average median pore radius and porosity display a strong negative correlation with supercritical CO 2 retention column height. Also, increasing bulk density is positively correlated with the supercritical CO 2 retention column height. One of the most important factors affecting sealing capacity and consequently the height of supercritical CO 2 column is sorting of the pore throats. We observed a strong positive correlation between pore throat sorting and height of CO 2 retention column, especially in shales. This correlation could not be observed in limestone samples. It suggests that the pore throat sorting is more controlling the sealing capacity in shales and shales with well sorted pore throats are the most reliable lithology as seal. We observed that Brunauer–Emmett–Teller (BET) surface area shows a very strong correlation with CO 2 retention column height in limestone samples while BET surface area did not display significant correlation in shales. Pore structure based on SEM micrographs exhibits strong correlation with CO 2 retention column height in limestones. Both intercrystalline and vuggy structures have negative correlations while intergranular texture has positive correlation in limestone with respect to CO 2 retention column height. Textural effects observed on SEM micrographs did not show statistically significant correlation with supercritical CO 2 retention column height in shale samples. Finally, we showed that increasing hard/soft mineral index is strongly correlated with the displacement pressure in limestone samples. Vuggy texture displays a relatively strong and negative correlation with displacement pressure values at 10% mercury saturation in shale samples.

54 ENVIRONMENTAL SCIENCES↗

Cesium Ion Exchange Using Crystalline Silicotitanate with 5.6 M Sodium Simulant

The Low-Activity Waste Pretreatment System (LAWPS) facility is planned to pretreat Hanford tank waste supernate by filtering to remove solids and processing through ion exchange columns to remove cesium. The ion exchange media is currently (since 2018) targeted to be crystalline silicotitanate (CST). This material has been produced as an engineered form (generally spherical beads) by Honeywell UOP LLC (Des Plaines, IL). Previous forms of this media have been tested in a wide array of simulants and process scales, but column breakthrough and batch contact testing to date on actual tank waste has been limited to a few tank wastes. Washington River Protection Solutions requested a series of studies to demonstrate Cs load behavior in a small column format and determine if a simple batch contact test with CST can be used to qualify tank waste supernate prior to processing it in the LAWPS. The goal of the batch contact testing is to determine if there are any issues with the tank waste that would preclude Cs removal by the ion exchanger. Testing was conducted with IONSIV TM R9140-B CST provided by Honeywell UOP in 2018 (Batch 2081000057). The CST was received in the sodium (Na) form, so no pretreatment conditioning to convert to the Na form was required. Before use in testing, the CST was passed through a #25 sieve (710-micron openings) and collected on a #60 sieve (250-micron openings) with the intent of removing any large and fine particles. Physical properties were measured on the CST including particle size distribution (d50 = 570 microns) and scanning electron micrographic examination. The CST was rinsed with water until the contact solution was visually nearly clear. The CST bed density (1.00 g/mL) and CST bed void fraction (0.656) were measured on the sieved and rinsed CST. The batch contact testing varied Cs concentration in a 5.6 M Na simple simulant solution. Testing was conducted in a liquid volume to solids mass ratio of 200. The distribution coefficient (K d ) was determined to be 770 mL/g at the Cs equilibrium condition of 8.0 μg/mL; with a bed density of 1.00 g/mL, this corresponds to a predicted 50% Cs breakthrough of 770 bed volumes (BVs). The Cs load capacity at 8.0 μg/mL equilibrium condition was determined to be 6.16 mg Cs/g dry CST. The column testing was prototypic to the intended LAWPS operations in a lead-lag column format, albeit on a small-scale basis with 10-mL CST beds. The feed was processed downflow through the lead column and then through the lag column. Three flowrates were tested: 1.19, 1.99, and 4.56 BV/h. The feed was displaced with 0.1 M NaOH, and then the columns were rinsed with water sequentially through the lead then lag columns. One column system was evaluated top to bottom with a gamma scanner to assess the axial Cs loading. Table ES.1 summarizes the relevant Cs loading characteristics.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Small to Full Height Scale Comparisons of Cesium Ion Exchange Performance with Crystalline Silicotitanate

The U.S. Department of Energy’s (DOE) Hanford Site houses 56 million gallons of high-level radioactive waste generated from plutonium production from 1944 to 1988. The supernatant waste, currently stored in underground tanks, is intended to be vitrified following filtration and 137 Cs removal at the Hanford Waste Treatment and Immobilization Plant (WTP) Low-Activity Waste (LAW) Vitrification Facility. The WTP Pretreatment Facility will not be operational for several years. The Tank Side Cesium Removal (TSCR) system is a technology demonstration that will remove cesium from tank waste supernate to support directly feeding LAW to the vitrification facility. The 137 Cs removal is important to meet the WTP LAW contract specification and ultimately for creating a contact-handled waste form. The waste acceptance criteria (WAC) limit for the WTP LAW Facility is <3.18E-5 Ci 137 Cs per mole Na. The TSCR system is skid mounted and employs two key technologies: dead end filtration for solids removal and ion exchange (IX) for cesium removal. Filtration is necessary to protect the functionality of the IX columns. The IX process utilizes sodium form crystalline silicotitanate (CST) IX media produced by UOP Honeywell, LLC (Des Plaines, IL) under the product name IONSIV R9140-B, 18 x 50 mesh, in a lead-lag-polish column configuration. Each column contains a CST bed height of 92 inches and a volume of approximately 157 gallons of CST IX media. The full-scale TSCR operation will run at a residence time of 1.9 bed volumes (BV)/h, which results in a superficial velocity of 7.3 cm/min and a flowrate of ~5 gal/min. Column testing at small (2.5% of the full bed height), medium (12% of the full bed height), and full-height scales has been previously conducted to evaluate process variables and scale up performance of Cs exchange onto the CST. Cesium load performances from various sieve cuts at the small scale indicated that a 30-mesh sieve cut be tested to determine if it better reflects the 12% and full-height column performances at the small scale. Two process flowrates were tested in the small-column configuration with <30-mesh CST and simulant solutions. These tests were compared to full-height column tests at the same residence times to assess CST particle size effect on column scaling. Table S.1 summarizes the observed column performance determined for the two flowrates juxtaposed to the previous work with 5.6 M Na simulant at higher scales (used as benchmarks). The WAC breakthroughs between the small and full-height tests at 1.3 BV/h differed by ~59 BVs. The WAC breakthroughs for small, medium, and full-height tests at 1.8 BV/h were consistent at 240 BVs. The 50% Cs breakthroughs were nominally equivalent for all column tests. The common transition zones and onsets of Cs breakthrough at the 1.8 BV/h tests indicated that the Cs mass transfers were equivalent and thus the <30-mesh CST Cs load performance at the small scale successfully modeled that of the full-height system. It is recommended that the <30-mesh CST be used in subsequent 10-mL CST bed tests.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

On-Chip Microfluidic Components for In Situ Analysis, Separation, and Detection of Amino Acids

The Astrobiology Analytical Laboratory at GSFC has identified amino acids in meteorites and returned cometary samples by using liquid chromatography-electrospray ionization time-of-flight mass spectrometry (LCMS). These organic species are key markers for life, having the property of chirality that can be used to distinguish biological from non-biological amino acids. One of the critical components in the benchtop instrument is liquid chromatography (LC) analytical column. The commercial LC analytical column is an over- 250-mm-long and 4.6-mm-diameter stainless steel tube filled with functionized microbeads as stationary phase to separate the molecular species based on their chemistry. Miniaturization of this technique for spaceflight is compelling for future payloads for landed missions targeting astrobiology objectives. A commercial liquid chromatography analytical column consists of an inert cylindrical tube filled with a stationary phase, i.e., microbeads, that has been functionalized with a targeted chemistry. When analyte is sent through the column by a pressurized carrier fluid (typically a methanol/ water mixture), compounds are separated in time due to differences in chemical interactions with the stationary phase. Different species of analyte molecules will interact more strongly with the column chemistry, and will therefore take longer to traverse the column. In this way, the column will separate molecular species based on their chemistry. A lab-on-chip liquid analysis tool was developed. The microfluidic analytical column is capable of chromatographically separating biologically relevant classes of molecules based on their chemistry. For this analytical column, fabrication, low leak rate, and stationary phase incorporation of a serpentine microchannel were demonstrated that mimic the dimensions of a commercial LC column within a 5 10 1 mm chip. The microchannel in the chip has a 75- micrometer-diameter oval-shaped cross section. The serpentine microchannel has four different lengths: 40, 60, 80, and 100 mm. Functionized microbeads were filled inside the microchannel to separate molecular species based on their chemistry.

Zheng, Yun↗

TRANSIENT HEAT TRANSFER ANALYSIS FOR ION-EXCHANGE WASTE REMOVAL PROCESS

The small column ion exchange (SCIX) process treats low curie salt (LCS) waste before feeding it to the saltstone facility to be made into grout. Through this process, radioactive cesium from the salt solution is absorbed into the CST bed. A CST column loaded with radioactive cesium will generate significant heat from radiolytic decay. If engineering designs of the CST sorption column can not handle this thermal load, hot spots may develop locally within the column and degrade the performance of the ion-exchange process. The CST starts to degrade at about 80 to 85 C, and the CST completely changes to another material above 120 C. In addition, the process solution will boil around 130 C. If the column boiled dry, the sorbent could plug the column and require replacement of the column module. The objective of the present work is to compute temperature distributions across the column as a function of transit time after the initiation of accidents when there is loss of the salt solution flow in the CST column under abnormal conditions of the process operations. In this situation, the customer requested that the calculations should be conservative in that the model results would show the maximum centerline temperatures achievable by the CST design configurations. The thermal analysis results will be used to evaluate the fluid temperature distributions and the process component temperatures within the ion exchange system. This information will also assist in the system design and maintenance.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Additively manufactured cryogenic microchannel distillation device for air separation

Abstract The efficiency of air separation is tested using three different small‐scale cryogenic distillation columns. The performance of a random packed column is compared to the performance of two microchannel distillation (MCD) columns that use thin wicking structures and gas flow channels to achieve process intensification. The MCD columns tested include a plate‐type layered column and an additively manufactured porous honeycomb (AMPH) column. For columns with 25.4 cm of active height and run under similar conditions, the packed, plate‐type layering, and AMPH columns achieved approximate height equivalent of a theoretical plate (HETP) values of 5.5, 3.7, and 3.2 cm for nitrogen, and 5.9, 4.9, and 3.3 cm for argon. The AMPH column can produce up to 0.4 SLM of more than 90% purity oxygen with 12 W of cooling lift. These results demonstrate the feasibility of using additive manufacturing to construct MCD devices and pave a way for constructing novel MCD designs.

36 MATERIALS SCIENCE↗

Device-scale CFD modeling of gas-liquid multiphase flow and amine absorption for CO2 capture

In this paper we aim to develop a validated device-scale CFD model that can predict quantitatively both hydrodynamics and CO2 capture efficiency for an amine-based solvent absorber column with random Pall ring packing. A Eulerian porous-media approach and a two-fluid model were employed, in which the momentum and mass transfer equations were closed by literature-based empirical closure models. We proposed a hierarchical approach for calibrating the parameters in the closure models to make them accurate for the packed column. Specifically, a parameter for momentum transfer in the closure was first calibrated based on data from a single experiment. With this calibrated parameter, a parameter in the closure for mass transfer was next calibrated under a single operating condition. Last, the closure of the wetting area was calibrated for each gas velocity at three different liquid flow rates. For each calibration, cross validations were pursued using the experimental data under operating conditions different from those used for calibrations. This hierarchical approach can be generally applied to develop validated device-scale CFD models for different absorption columns.

Pan, Wenxiao↗

Domestic wastewater treatment using tidal-flow cinder bed with Cyperus alternifolius

A lab-scale vertical flow cinder bed was set up to treat domestic wastewater. Cinder, which is a common coal waste from electricity generation, was used as the filter medium in the six vertical flow column beds in this study. Three of the six columns were planted with umbrella grass (Cyperus alternifolius) to mimic a wetland system and to investigate the effects of plant on the pollutant removal efficiencies of the column bed systems. The six column beds were divided into three groups, operating with different durations of wet and dry periods. Group 2 column beds, with 4 hours wet periods and 4 hours dry periods, showed the highest carbonaceous removal. Similar ammonia nitrogen removal efficiencies were demonstrated in column beds of group 2 and in column beds of group 3 (6 hours wet periods and 2 hours dry periods). Phosphorus removal efficiencies were not significantly different in all groups of column bed. No significant differences in pollutant removal were observed between planted and unplanted column beds in this study (p > 0.05).

01 COAL, LIGNITE, AND PEAT↗

THE RELATION BETWEEN GAS AND DUST IN THE TAURUS MOLECULAR CLOUD

We report a study of the relation between dust and gas over a 100 deg{sup 2} area in the Taurus molecular cloud. We compare the H{sub 2} column density derived from dust extinction with the CO column density derived from the {sup 12}CO and {sup 13}CO J = 1 {yields} 0 lines. We derive the visual extinction from reddening determined from 2MASS data. The comparison is done at an angular size of 200'' corresponding to 0.14 pc at a distance of 140 pc. We find that the relation between visual extinction A{sub V} and N(CO) is linear between A{sub V} {approx_equal} 3 and 10 mag in the region associated with the B213-L1495 filament. In other regions, the linear relation is flattened for A{sub V{approx}}> 4 mag. We find that the presence of temperature gradients in the molecular gas affects the determination of N(CO) by {approx}30%-70% with the largest difference occurring at large column densities. Adding a correction for this effect and accounting for the observed relation between the column density of CO and CO{sub 2} ices and A{sub V}, we find a linear relationship between the column of carbon monoxide and dust for observed visual extinctions up to the maximum value in our data {approx_equal}23 mag. We have used these data to study a sample of dense cores in Taurus. Fitting an analytical column density profile to these cores we derive an average volume density of about 1.4 x 10{sup 4} cm{sup -3} and a CO depletion age of about 4.2 x 10{sup 5} yr. At visual extinctions smaller than {approx}3 mag, we find that the CO fractional abundance is reduced by up to two orders of magnitude. The data show a large scatter suggesting a range of physical conditions of the gas. We estimate the H{sub 2} mass of Taurus to be about 1.5 x 10{sup 4} M{sub sun}, independently derived from the A{sub V} and N(CO) maps. We derive a CO integrated intensity to H{sub 2} conversion factor of about 2.1 x 10{sup 20} cm{sup -2} (K km s{sup -1}){sup -1}, which applies even in the region where the [CO]/[H{sub 2}] ratio is reduced by up to two orders of magnitude. The distribution of column densities in our Taurus maps resembles a log-normal function but shows tails at large and low column densities. The length scale at which the high column density tail starts to be noticeable is about 0.4 pc.

79 ASTRONOMY AND ASTROPHYSICS↗

DNA Sequencing Using capillary Electrophoresis

The overall goal of this program was to develop capillary electrophoresis as the tool to be used to sequence for the first time the Human Genome. Our program was part of the Human Genome Project. In this work, we were highly successful and the replaceable polymer we developed, linear polyacrylamide, was used by the DOE sequencing lab in California to sequence a significant portion of the human genome using the MegaBase multiple capillary array electrophoresis instrument. In this final report, we summarize our efforts and success. We began our work by separating by capillary electrophoresis double strand oligonucleotides using cross-linked polyacrylamide gels in fused silica capillaries. This work showed the potential of the methodology. However, preparation of such cross-linked gel capillaries was difficult with poor reproducibility, and even more important, the columns were not very stable. We improved stability by using non-cross linked linear polyacrylamide. Here, the entangled linear chains could move when osmotic pressure (e.g. sample injection) was imposed on the polymer matrix. This relaxation of the polymer dissipated the stress in the column. Our next advance was to use significantly lower concentrations of the linear polyacrylamide that the polymer could be automatically blown out after each run and replaced with fresh linear polymer solution. In this way, a new column was available for each analytical run. Finally, while testing many linear polymers, we selected linear polyacrylamide as the best matrix as it was the most hydrophilic polymer available. Under our DOE program, we demonstrated initially the success of the linear polyacrylamide to separate double strand DNA. We note that the method is used even today to assay purity of double stranded DNA fragments. Our focus, of course, was on the separation of single stranded DNA for sequencing purposes. In one paper, we demonstrated the success of our approach in sequencing up to 500 bases. Other application papers of sequencing up to this level were also published in the mid 1990's. A major interest of the sequencing community has always been read length. The longer the sequence read per run the more efficient the process as well as the ability to read repeat sequences. We therefore devoted a great deal of time to studying the factors influencing read length in capillary electrophoresis, including polymer type and molecule weight, capillary column temperature, applied electric field, etc. In our initial optimization, we were able to demonstrate, for the first time, the sequencing of over 1000 bases with 90% accuracy. The run required 80 minutes for separation. Sequencing of 1000 bases per column was next demonstrated on a multiple capillary instrument. Our studies revealed that linear polyacrylamide produced the longest read lengths because the hydrophilic single strand DNA had minimal interaction with the very hydrophilic linear polyacrylamide. Any interaction of the DNA with the polymer would lead to broader peaks and lower read length. Another important parameter was the molecular weight of the linear chains. High molecular weight (> 1 MDA) was important to allow the long single strand DNA to reptate through the entangled polymer matrix. In an important paper, we showed an inverse emulsion method to prepare reproducibility linear polyacrylamide polymer with an average MWT of 9MDa. This approach was used in the polymer for sequencing the human genome. Another critical factor in the successful use of capillary electrophoresis for sequencing was the sample preparation method. In the Sanger sequencing reaction, high concentration of salts and dideoxynucleotide remained. Since the sample was introduced to the capillary column by electrokinetic injection, these salt ions would be favorably injected into the column over the sequencing fragments, thus reducing the signal for longer fragments and hence reading read length. In two papers, we examined the role of individual components from the sequencing reaction and then developed a protocol to reduce the deleterious salts. We demonstrated a robust method for achieving long read length DNA sequencing. Continuing our advances, we next demonstrated the achievement of over 1000 bases in less than one hour with a base calling accuracy of between 98 and 99%. In this work, we implemented energy transfer dyes which allowed for cleaner differentiation of the 4 dye labeled terminal nucleotides. In addition, we developed improved base calling software to help read sequencing when the separation was only minimal as occurs at long read lengths. Another critical parameter we studied was column temperature. We demonstrated that read lengths improved as the column temperature was increased from room temperature to 60 C or 70 C. The higher temperature relaxed the DNA chains under the influence of the high electric field.

59 BASIC BIOLOGICAL SCIENCES↗

Reduced Temperature Cesium Removal from AP-101 Using Crystalline Silicotitanate

The Tank Side Cesium Removal (TSCR) system, currently operational under Washington River Protection Solutions LLC (WRPS), sends initial low-activity Hanford waste tank supernate feed to the Hanford Waste Treatment and Immobilization Plant (WTP) Low-Activity Waste (LAW) Facility. In addition to entrained solids removal from the supernate, the primary goal of TSCR is to remove cesium-137 ( 137 Cs) by ion exchange, allowing contact handling of the liquid effluent product at the WTP. Crystalline silicotitanate (CST) ion exchange media, manufactured by Honeywell UOP, LLC (product IONSIV™ R9140-B), was selected as the ion exchange media at TSCR. Laboratory-scale ion exchange processing using TSCR prototypic unit operations continues to contribute toward WRPS establishing accurate process flowsheets for the individual feed campaigns planned for TSCR. This report describes the small-scale ion exchange testing with 14.0 L of diluted and filtered supernate from tank 241-AP-101 (AP-101DF) at 16 °C (62 °F) to demonstrate processing at temperature conditions that are more prototypic of what the TSCR system could experience during colder seasons of the year. Since CST Cs capacity increases with decreasing contact temperature, testing at the lower operating temperature will help to predict the maximum 137 Cs loading onto the CST in the TSCR system. One of the waste acceptance criteria (WAC) for the WTP Low-Activity Waste Facility is that the waste must contain less than 3.18×10 -5 Ci 137 Cs per mole of Na. For the AP-101DF tank waste to meet this criterion, only 0.144% of the influent 137 Cs concentration may be delivered to the WTP; this requires a Cs decontamination factor of 694. Testing with AP-101DF matched TSCR prototypic operations where a lead-lag configuration was used until the lag column reached the WAC limit, then a polish column was brought online for continued processing in a lead-lag-polish column configuration. Feed was processed at 1.9 bed volumes (BVs) per hour; the flowrate, in terms of contact time with the CST bed, matched the expected flowrate at TSCR. The Cs-decontaminated product was retained for vitrification testing (to be reported separately). The lead column reached 62% Cs breakthrough after processing ~1400 BVs of feed; the 50% Cs breakthrough occurred at 1250 BVs. Testing compared to previous AP-107 testing at 16 °C showed ~80 BV increases in volume processed to reach the WAC limit for both lead and lag columns. A similar slope in breakthrough curves for both tests indicates similar kinetic behavior, with variations in feed matrices (Na and Cs concentrations) likely responsible for the deviations in reaching the WAC limit. The Cs effluent from the lag column reached the WAC limit after processing 875 BVs. Anticipating this breakthrough point, the polish column was preemptively installed at 770 BVs. Cs breakthrough from the lag column began at 300 BVs, reaching 5.32×10 0 µCi/mL, or 5.6 % Cs breakthrough, after processing all 1400 BVs of feed. Table S.1 and Figure S.1 summarize the observed column performance and relevant Cs loading characteristics.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

PEROXIDE DESTRUCTION TESTING FOR THE 200 AREA EFFLUENT TREATMENT FACILITY

The hydrogen peroxide decomposer columns at the 200 Area Effluent Treatment Facility (ETF) have been taken out of service due to ongoing problems with particulate fines and poor destruction performance from the granular activated carbon (GAC) used in the columns. An alternative search was initiated and led to bench scale testing and then pilot scale testing. Based on the bench scale testing three manganese dioxide based catalysts were evaluated in the peroxide destruction pilot column installed at the 300 Area Treated Effluent Disposal Facility. The ten inch diameter, nine foot tall, clear polyvinyl chloride (PVC) column allowed for the same six foot catalyst bed depth as is in the existing ETF system. The flow rate to the column was controlled to evaluate the performance at the same superficial velocity (gpm/ft{sup 2}) as the full scale design flow and normal process flow. Each catalyst was evaluated on peroxide destruction performance and particulate fines capacity and carryover. Peroxide destruction was measured by hydrogen peroxide concentration analysis of samples taken before and after the column. The presence of fines in the column headspace and the discharge from carryover was generally assessed by visual observation. All three catalysts met the peroxide destruction criteria by achieving hydrogen peroxide discharge concentrations of less than 0.5 mg/L at the design flow with inlet peroxide concentrations greater than 100 mg/L. The Sud-Chemie T-2525 catalyst was markedly better in the minimization of fines and particle carryover. It is anticipated the T-2525 can be installed as a direct replacement for the GAC in the peroxide decomposer columns. Based on the results of the peroxide method development work the recommendation is to purchase the T-2525 catalyst and initially load one of the ETF decomposer columns for full scale testing.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Size-resolved ice nucleating particle (INP) concentrations from the MOSAiC campaign

Sample collection: Ground-based immersion mode ice nucleation measurements were conducted on samples collected at the U.S. DOE ARM AMF2 onboard the R/V Polarstern P-deck during MOSAiC from 23 Oct 2019 to 01 Oct 2020. Samples were collected using a Davis Rotating-drum Unit for Monitoring (DRUM; DRUMAir, LLC) cascading impactor in 4 stages (i.e., size bins). Instrument information on the model used, the DA400, can be found at the DRUMAir website (http://www.drumair.com/). Stages A, B, C, and D had particle size cuts at 2.96, 1.21, 0.34, and 0.15 &micro;m in particle diameter, respectively. Strips of sample substrate (PFA, perfluoroalkoxy; McMaster) were adhered to each disc in each stage and coated with petrolatum to enable particles to stick on impact. The discs move slowly over time, such that aerosol loading is streaked onto the PFA. Every 24 hours, a blank is created on the PFA to separate daily samples. During MOSAiC, the pump typically pulled 20 &ndash; 35 lpm (average of 32 lpm) at the inlet with all the discs in place in each stage. Daily samples were collected for each of the four stages, equaling 28,800 &ndash; 50,400 total L of air (average of 46,080 L total L of air) per sample. Discs rotated for approximately 24 days before the sampling per strip was complete and changed to a new disc. Discs were stored frozen after collection. Sample preparation for analysis: Following collection and transport from MOSAiC to the Kreidenweis/DeMott laboratory, care of PI Creamean, in Fort Collins, CO, strips were removed from the discs and cut up to separate daily samples. Each daily portion of the strip was stored in separate sterile 15-mL centrifuge tubes and stored in a standard commercial freezer until analysis (approximately 4 &ndash; 12 months after collection). Sample analysis: Drop freezing assays (DFAs) were conducted on one daily sample set every 3 &ndash; 4 days of the study for all four stages using the Colorado State University (CSU) cold plate (CP). Sample set days were chosen to cover the entire year of MOSAiC and avoiding days where the AOS purge system was activated. Immediately after removal from the freezer, 2 mL of 0.1-&micro;m filtered deionized water was added with a single-use sterile syringe directly to the tubes, then mixed using a vortex mixer for at least 30 minutes at 500 rpm to resuspend particles from the PFA into the deionized water. Following sample preparation, another single-use syringe was used to create 100 aliquots on a 3-inch diameter copper plate, then covered with a transparent plastic dome. The drops were approximately the same volume (2.5 &micro;L each), though careful inspection. The plate was cooled at approximately 3 &ndash; 10 K min-1 from room temperature until all drops froze on the plate. Temperature was measured by an Omega thermocouple probes and meter. Drop freezing was visually detected but recorded through monitoring software to provide the time frozen, channel of the meter used, temperature, and cooling rate for each drop. Not all 100 drops were always detected; the total number of rows in each data file equals the number of drops recorded, which typically was > 80 %. Each sample was tested three times (i.e., a new set of 100 drops was created for each test). Data provided are files containing these parameters. From the freezing temperatures recorded, the fraction frozen was and INP concentrations were calculated per L of air using the equation from Vali (1971): [INPs] = &minus;(ln(f)/Valiquot)*(Vsuspension/Vair) where f is the proportion of droplets not frozen, Valiquot is the volume of each aliquot (i.e., 2.5e-6 L), Vsuspension is the volume of the suspension (i.e., 0.002 L), and Vair is the volume of air per sample (i.e., 36000 L). Data usage guidance: There are three files included with this dataset: (1) dumcp_inp_concentrations.csv which includes cumulative INP concentrations binned every 0.5 &deg;C from 0 to &ndash;30 &deg;C for all samples and size ranges (i.e., DRUM stages) processed via DFA using the CSU CP; (2) dumcp_inp_standard_deviation.csv which includes the standard deviations for all samples and temperatures in dumcp_inp_concentrations.csv; and (3) dumcp_blank_concentrations_standard_deviation.csv which includes the INP concentrations and standard deviations for the deionized water and PFA blanks binned every 0.5 &deg;C from 0 to &ndash;30 &deg;C. The first column in each file represents the freezing temperature in &deg;C binned every 0.5 &deg;C from 0 to &ndash;30 &deg;C (first cell in this column = header = &ldquo;temp&rdquo;). The second column in each file represents the standard deviation of each temperature bin in &deg;C (first cell in this column = header = &ldquo;temperr&rdquo;). For file (1) dumcp_inp_concentrations.csv, the remaining columns indicate the INP concentrations per L of air for each temperature bin. For each sample column, the header in the first row indicates the stage (i.e., size bin as &ldquo;A_&rdquo;, &ldquo;B_&rdquo;, &ldquo;C_&rdquo;, or &ldquo;D_&rdquo;) and date (&ldquo;_yyyymmdd) of collection. For file (2) dumcp_inp_standard_deviation.csv, the remaining columns indicate the INP concentration standard deviation per L of air for each temperature bin. For each sample column, the header in the first row indicates the stage (i.e., size bin as &ldquo;A_&rdquo;, &ldquo;B_&rdquo;, &ldquo;C_&rdquo;, or &ldquo;D_&rdquo;) and date (&ldquo;_yyyymmdd) of collection. For file (3) dumcp_blank_concentrations_standard_deviation.csv, the remaining columns indicate the INP concentrations and standard deviations for the deionized water blank (&ldquo;di_0.1&rdquo; and &ldquo;di_0.1sd&rdquo; for the concentrations and standard deviations, respectively) and PFA blank (&ldquo;pfa&rdquo; and &ldquo;pfasd&rdquo; for the concentrations and standard deviations, respectively). Please see Creamean et al. (2019a; 2018a; 2018b; 2019b) for additional details on DRUM sample collection and offline processing. For questions or help with data interpretation, contact Dr. Jessie Creamean (jessie.creamean@colostate.edu). References: Creamean, J. M., Mignani, C., Bukowiecki, N., and Conen, F.: Using spectra characteristics to identify ice nucleating particle populations during winter storms in the Alps, Atmos. Chem. Phys., 19, 8123&ndash;8140, 2019a. Creamean, J. M., Kirpes, R. M., Pratt, K. A., Spada, N. S., Maahn, M., de Boer, G., Schnell, R. C., and China, S.: Marine and terrestrial influences on ice nucleating particles during continuous springtime measurements in an Arctic oilfield location, Atmospheric Chemistry and Physics, 18, 18023-18042, 10.5194/acp-18-18023-2018, 2018a. Creamean, J. M., Primm, K. M., Tolbert, M. A., Hall, E. G., Wendell, J., Jordan, A., Sheridan, P. J., Smith, J., and Schnell, R. C.: HOVERCAT: A novel aerial system for evaluation of aerosol-cloud interactions, Atmospheric Measurement Techniques, 11, 3969-3985, 10.5194/amt-11-3969-2018, 2018b. Creamean, J. M., Cross, J. N., Pickart, R., McRaven, L., Lin, P., Pacini, A., Hanlon, R., Schmale, D. G., Ceniceros, J., Aydell, T., Colombi, N., Bolger, E., and DeMott, P. J.: Ice nucleating particles carried from below a phytoplankton bloom to the Arctic atmosphere, Geophys. Res. Lett., 46, 8572-8581, https://doi.org/10.1029/2019GL083039, 2019b. Vali, G.: Quantitative Evaluation of Experimental Results an the Heterogeneous Freezing Nucleation of Supercooled Liquids, Journal of the Atmospheric Sciences, 28, 402-409, 10.1175/1520-0469(1971)028<0402:qeoera>2.0.co;2, 1971.

4-stage DRUM aerosol collector (DA400),Ice nuclei,↗

"Cloud Slicing" : A New Technique to Derive Tropospheric Ozone Profile Information from Satellite Measurements

A new technique denoted cloud slicing has been developed for estimating tropospheric ozone profile information. All previous methods using satellite data were only capable of estimating the total column of ozone in the troposphere. Cloud slicing takes advantage of the opaque property of water vapor clouds to ultraviolet wavelength radiation. Measurements of above-cloud column ozone from the Nimbus 7 total ozone mapping spectrometer (TOMS) instrument are combined together with Nimbus 7 temperature humidity and infrared radiometer (THIR) cloud-top pressure data to derive ozone column amounts in the upper troposphere. In this study tropical TOMS and THIR data for the period 1979-1984 are analyzed. By combining total tropospheric column ozone (denoted TCO) measurements from the convective cloud differential (CCD) method with 100-400 hPa upper tropospheric column ozone amounts from cloud slicing, it is possible to estimate 400-1000 hPa lower tropospheric column ozone and evaluate its spatial and temporal variability. Results for both the upper and lower tropical troposphere show a year-round zonal wavenumber 1 pattern in column ozone with largest amounts in the Atlantic region (up to approx. 15 DU in the 100-400 hPa pressure band and approx. 25-30 DU in the 400-1000 hPa pressure band). Upper tropospheric ozone derived from cloud slicing shows maximum column amounts in the Atlantic region in the June-August and September-November seasons which is similar to the seasonal variability of CCD derived TCO in the region. For the lower troposphere, largest column amounts occur in the September-November season over Brazil in South America and also southern Africa. Localized increases in the tropics in lower tropospheric ozone are found over the northern region of South America around August and off the west coast of equatorial Africa in the March-May season. Time series analysis for several regions in South America and Africa show an anomalous increase in ozone in the lower troposphere around the month of March which is not observed in the upper troposphere. The eastern Pacific indicates weak seasonal variability of upper, lower, and total tropospheric ozone compared to the western Pacific which shows largest TCO amounts in both hemispheres around spring months. Ozone variability in the western Pacific is expected to have greater variability caused by strong convection, pollution and biomass burning, land/sea contrast and monsoon developments.

Ziemke, J. R.↗