Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “building”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

Building envelope anomaly characterization and simulation using drone time-lapse thermography

Defects in building envelopes deteriorate over time without being visible to the human eye, while significantly impacting energy performance due to unaccounted heat transfer. Defects can be characterized in the infrared (IR) spectrum. However, IR readings are typically recorded at singular points in time, when in several cases anomalies can only be revealed at specific times of the day, possibly in different seasons of the year. This paper presents a novel workflow for 3D envelope defect characterization and modeling using aerial time-lapse IR data collection using drones. A comprehensive envelope thermal profile is developed for a case study building employing the photogrammetry software Agisoft Photoscan, which generates temporal IR inspections of building skins using multiple thermography orthomosaics. Point-cloud data is then translated into a CAD model and thermal zones for whole Building Energy Modeling (BEM) using Honeybee as a frontend to EnergyPlus to showcase the potential of inclusion of detailed 4D data. Envelope contributions in this case study’s anomalies showed heat losses of 6447.6 kWh, and Energy Use Intensity (EUI) differences of ~2 kWh/m 2 /year from the baseline. Finally, why there is currently little translation of this work in BEM software is discussed, while identifying limitations and future research in the employment of time-lapse thermography using drones for more accurate building envelope inspection and modeling.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dynamic modelling and control strategy of a temperature-driven metal hydride cooling system for buildings

A temperature-driven coupled metal hydride (MH) based thermal energy storage (TES) system can allow to shave and shift the peak energy demand in buildings. The high energy density and long-term (seasonal) energy storage capability are its major advantages over other energy storage methods. The dynamic nature of the MH operation, however, requires controlled hydrogen transfer between the coupled MHs at a rate needed to meet the building's transient load. While temperature-driven MH systems are studied in the literature, their application in buildings and control are scarcely reported. Here, this paper presents a control-based dynamic modeling of the temperature-driven coupled MH-TES system for building cooling applications. The dynamic model is developed in MATLAB(R) Simulink environment, considering the thermodynamic and kinetic behaviors of the MH systems. Based on a preliminary analysis of a property database of over 337 hydrides, we select around 1600 MH pairs suitable for building cooling applications. Each of these MH pairs is studied for their performance using the dynamic model, and among all, Zr 0.76 Ti 0.24 Ni 1.16 Mn 0.63 V 0.14 Fe 0.18 -Ti 0.85 Zr 0.15 Cr 1.2 Mn 0.8 MH pair showed fast dynamics along with high coefficient of performance (COP) of 0.71. A parametric investigation is performed on this MH pair to understand the effect of operating temperatures. Finally, three proportional-integral (PI) feedback controllers are investigated to regulate the temperature, pressure and mass exchange between the coupled MH pairs. The developed PI controller is sufficiently capable of rejecting the signal noise from the hydrogen flow and internal heat exchange processes with root mean square error of 5.78 W between reference and actual cooling load.

08 HYDROGEN↗

Experimental validation of a co-simulation architecture for modeling whole-building and detailed electrical distribution performance

This article presents an experimental validation of a co-simulation architecture for simultaneously modeling whole-building energy performance and detailed building electrical distribution system performance. The co-simulation architecture consists of a whole-building energy model (EnergyPlus®) embedded within a Modelica-based building electrical distribution system library called the Building Electrical Efficiency Analysis Model (BEEAM) using the Functional Mock-up Interface standard. We validate the model using experimental data collected at a full-scale test cell within Lawrence Berkeley National Laboratory’s FLEXLAB® facility. In conclusion, we show that the co-simulation model accurately predicts the electrical, mechanical, and thermal performance of the test cell for typical loads with both an AC and a DC electrical distribution topology.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

The Impact of DOE Building Technology Energy Efficiency Programs on U.S. Employment, Income, and Investment

To more fully evaluate its programs to increase the energy efficiency of the U.S. residential and commercial building stock, the U.S. Department of Energy’s Office of Energy Efficiency and Renewable Energy (EERE) assesses the macroeconomic impacts of those programs, specifically on national employment, wage income, and (most recently) investment. The analysis is conducted using the Impact of Sector Energy Technologies (ImSET) model, a special-purpose 188-sector input-output model of the U.S. economy designed specifically to evaluate the impacts of energy efficiency investments and saving. For the analysis described in the paper, ImSET was amended to provide estimates of sector-by-sector capital requirements and investment. In the scenario of the Fiscal Year (FY) 2005 Buildings Technology (BT) program, the technologies and building practices being developed and promoted by the BT program have the prospect of saving about 2.9×1015 Btu in buildings by the year 2030, about 27% of the expected growth in buildings energy consumption by the year 2030. The analysis reported in the paper finds that, by the year 2030, these savings have the potential to increase employment by up to 446,000 jobs, increase wage income by $7.8 billion, reduce needs for capital stock in the energy sector and closely related supporting industries by about $207 billion (and the corresponding annual level of investment by $13 billion), and create net capital savings that are available to grow the nation’s future economy.

economic impact↗

Experimental apparatus and methodology to test and quantify thermal performance of micro and macro-encapsulated phase change materials in building envelope applications

Thermal energy storage (TES) is used as a viable technology to shift peak electricity demand caused by the space cooling requirements in buildings. Passive TES is implemented in building envelope via micro and macroencapsulation methods. This study describes the use of a state-of-the-art laboratory to test different PCM inclusions in simplified building walls. A microencapsulated PCM and two macroencapsulated PCMs are tested in a controlled environment to gather data for validation purposes of PCM modelling algorithms in building energy modelling programs. Data indicates that the chamber environment and the heating and cooling system can conduct full-cycle tests of wall panels with PCM inclusions. This study also generates data from parallel tests on 4 wall panels which can be used in building energy modelling programs to validate the PCM modelling algorithms. The cyclic tests also capture the thermal effects of PCMs and complex PCM behaviors like sub-cooling in PCM hydrate-salts.

25 ENERGY STORAGE↗

The international implications of national and local coordination on building energy codes: Case studies in six cities

Building energy efficiency is an important strategy for reducing greenhouse gas emissions globally. In fact, 55 countries have included building energy efficiency in their Nationally Determined Contributions (NDCs) under the Paris Agreement. This research uses building energy code implementation in six cities across different continents as case studies to assess what it may take for countries to implement the ambitions of their energy efficiency goals. Specifically, we look at the cases of Bogota, Colombia; Da Nang, Vietnam; Eskisehir, Turkey; Mexico City, Mexico; Rajkot, India; and Tshwane, South Africa, all of which are “deep dive” cities under the Sustainable Energy for All's Building Efficiency Accelerator. The research focuses on understanding the baseline with existing gaps in implementation and coordination. The methodology used a combination of surveys on code status and interviews with stakeholders at the local and national level, as well as review of published documents. We looked at code development, implementation, and evaluation. The cities are all working to improve implementation, however, the challenges they currently face include gaps in resources, capacity, tools, and institutions to check for compliance. Better coordination between national and local governments could help improve implementation, but that coordination is not yet well established. For example, all six of the cities reported that there was little to no involvement of local stakeholders in development of the national code; only one city reported that it had access to national funding to support code implementation. More robust coordination could better link cities with capacity building and funding for compliance, and ensure that the code reflects local priorities. By understanding gaps in implementation, it can also help in designing more targeted interventions to scale up energy savings.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A review of preserving privacy in data collected from buildings with differential privacy

Significant amounts of data are collected in buildings. While these data have great potential for maximizing the energy efficiency of buildings in general, only a small portion of the data are accessible to researchers, government, and industry for analyses. Concerns about privacy are one of the major barriers prohibiting access to these data. Privacy preservation techniques are generally applied to this problem not only to preserve underlying privacy but also to improve the usefulness of data. Among various privacy preserving techniques, differential privacy has become one of the more popular solutions since its introduction in 2006. Differential privacy is a mathematical measure for protecting privacy so that one's privacy cannot be incurred by participating in a database. Additionally, although significant research improvements have been made for more than a decade, applying differential privacy to data collected in buildings is still an immature field of study. Because implementing differential privacy on a certain use case is not straightforward and can be achieved with various configurations, it is important to understand variation of configurations with different use cases around data collected from buildings. This literature review aims to introduce what has been done to implement differential privacy in data collected in buildings, and to discuss associated challenges and potential future research opportunities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Effect of build geometry on the microstructural development of 316L parts produced by additive manufacturing

Highlights: • Stainless steel ribs were created via direct metal laser sintering to investigate microstructural effect of part design. • EBSD confirmed the presence of large elongated grains in the center of the part, with preferred orientation. • Small grains at the rib surface were found to grow towards the center of the rib with random orientation. • By changing rib thickness and build angle varying texture was observed in the final products. • Large intragranular misorientations were observed in all samples. - Abstract: Additive manufacturing (AM) technology has shown great potential in manufacturing complex products, such as lattice structures without extensive tooling. The focus of this study was to understand the effect of the part geometry on the resulting microstructure. Direct metal laser sintering was used for fabrication of ribs with thicknesses varying between 0.2 and 3.0 mm as well as inclined ribs the with build angles of 30° and 45°. The investigation showed that grains were growing in an epitaxial manner parallel to the building direction. The large elongated grains had a preferential orientation, resulting from the temperature gradient. Additionally, it was found that small grains had formed close to the part surface which were inclined towards the center of the rib. In contrast to the elongated grains, they had a random orientations. The results also indicated that at build angles below 45°, the formed microstructure consisted of the large grains elongated in the building direction. For the used process parameters, the critical part thickness to avoid large elongated grains was found to be about 0.4 mm. These findings allowed us to establish the basics for design rules when it comes to thin wall structures.

36 MATERIALS SCIENCE↗

Impacts of the morphology of new neighborhoods on microclimate and building energy

In anticipation of emerging global urbanization and consequent increases in energy use and carbon dioxide emissions, better understanding and quantification of climate effects on energy use in cities are needed, requiring coordinated research into large-scale, regional, and microclimate impacts to and from the city structure. The methodology described here addresses this need by (1) demonstrating a process for creating and testing example morphologies for new neighborhoods for their impact on local and regional meteorology within a two-way-coupled four-domain nested mesoscale weather model (6 km horizontal resolution outer domain, 90 m horizontal innermost domain) and (2) allocating resulting building-level meteorological profiles to each building in a neighborhood for parallel computation of building-by-building energy use. Our Chicago Loop test case shows that the morphology of even a small new added development to a neighborhood affects not only its own microclimate, but also the microclimate of the original neighborhood to which the development was added, and that these changes in microclimate affect both neighborhoods’ building energy use. Furthermore, this method represents an important step toward quantifying and analyzing the relationships among climatic conditions, urban morphology, and energy use and using these relationships to inform energy-efficient urban development and planning.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Desiccants enabling energy-efficient buildings: A review

Buildings account for about 39% of the total energy consumption in the United States. Developing highly energy-efficient and environmentally friendly systems that are either actively or passively integrated into buildings plays a crucial role in decarbonizing the building sector. Among various technologies, desiccant-based energy systems have received particular attention in recent years due to their unique advantages, such as being thermally driven using low-grade waste or solar energies and being reliable over a wide range of operating ranges. Extensive research efforts have been exerted on desiccant-enabled technologies at both material and system levels aiming to increase their performance and achieve high technological readiness levels. The present review paper comprehensively discusses research works made at the system level. It overviews desiccant-based air conditioning systems, desiccant-based humidity pumps, desiccant-based thermal energy storage systems, and desiccant-based appliances. The study identifies challenges and opportunities to accelerate the commercialization of desiccant-enabled technologies. It is found that desiccant materials offer great promise to improve energy efficiency and functionality of future buildings through decoupling the latent and sensible cooling loads in air conditioning systems, humidity pumps integrated into building facades, and next-generation appliances. However, commercial viability and widespread acceptance of desiccant-based systems have been hampered by several major obstacles, including liquid and air flow mal-distribution and inferior thermo-physical properties of desiccant materials resulting in low ab/adsorption and regeneration rates and bulky/costly systems.

25 ENERGY STORAGE↗

Night ventilation control strategies in office buildings

In moderate climates night ventilation is an effective and energy-efficient approach to improve the indoor thermal environment for office buildings during the summer months, especially for heavyweight construction. However, is night ventilation a suitable strategy for office buildings with lightweight construction located in cold climates? In order to answer this question, the whole energy-consumption analysis software EnergyPlus was used to simulate the indoor thermal environment and energy consumption in typical office buildings with night mechanical ventilation in three cities in northern China. The summer outdoor climate data was analyzed, and three typical design days were chosen. The most important factors influencing night ventilation performance such as ventilation rates, ventilation duration, building mass and climatic conditions were evaluated. When night ventilation operation time is closer to active cooling time, the efficiency of night ventilation is higher. With night ventilation rate of 10 ach, the mean radiant temperature of the indoor surface decreased by up to 3.9 C. The longer the duration of operation, the more efficient the night ventilation strategy becomes. The control strategies for three locations are given in the paper. Based on the optimized strategies, the operation consumption and fees are calculated. The results show that more energy is saved in office buildings cooled by a night ventilation system in northern China than ones that do not employ this strategy. (author)

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impacts of climate change, population growth, and power sector decarbonization on urban building energy use

Climate, technologies, and socio-economic changes will influence future building energy use in cities. However, current low-resolution regional and state-level analyses are insufficient to reliably assist city-level decision-making. Here we estimate mid-century hourly building energy consumption in 277 U.S. urban areas using a bottom-up approach. The projected future climate change results in heterogeneous changes in energy use intensity (EUI) among urban areas, particularly under higher warming scenarios, with on average 10.1–37.7% increases in the frequency of peak building electricity EUI but over 110% increases in some cities. For each 1 °C of warming, the mean city-scale space-conditioning EUI experiences an average increase/decrease of ~14%/ ~ 10% for space cooling/heating. Heterogeneous city-scale building source energy use changes are primarily driven by population and power sector changes, on average ranging from –9% to 40% with consistent south–north gradients under different scenarios. Across the scenarios considered here, the changes in city-scale building source energy use, when averaged over all urban areas, are as follows: –2.5% to –2.0% due to climate change, 7.3% to 52.2% due to population growth, and –17.1% to –8.9% due to power sector decarbonization. Our findings underscore the necessity of considering intercity heterogeneity when developing sustainable and resilient urban energy systems.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Seismic evaluation of vulnerability for SAMA educational buildings in Tehran

Earthquake is a destructive phenomenon that trembles different parts of the earth yearly and causes many destructions. Iran is one of the (high seismicity) quack- prone parts of the world that has received a lot of pecuniary damages and life losses each year, schools are of the most important places to be protected during such crisis.There was no special surveillance on designing and building of school's building in Tehran till the late 70's, and as Tehran is on faults, instability of such buildings may cause irrecoverable pecuniary damages and especially life losses, therefore preventing this phenomenon is in an urgent need.For this purpose, some of the schools built during 67-78 mostly with Steel braced frame structures have been selected, first, by evaluating the selected Samples, gathering information and Visual Survey, the prepared questionnaires were filled out. With the use of ARIA and SABA (Venezuela) Methods, new modified combined method for qualified evaluations was found and used.Then, for quantified evaluation, with the use of computer 3D models and nonlinear statically analysis methods, a number of selected buildings of qualified evaluation, were reevaluated and finally with nonlinear dynamic analysis method the real behavior of structures on the earthquakes is studied.The results of qualified and quantified evaluations were compared and a proper Pattern for seismic evaluation of Educational buildings was presented. Otherwise the results can be a guidance for the person in charge of retrofitting or if necessary rebuilding the schools.

58 GEOSCIENCES↗

System Identification of Burbank Six-Story Building Using Earthquake Data

This paper examines the problem of identifying the dynamic characteristics of an instrumented building using an input-output system identification method. The building studied was a six-story steel moment-resisting frame (SMRF) instrumented by the California Strong Motion Instrumentation Program (CSMIP). The building was shaken by several earthquakes and strong motion data of the building response was recorded during these earthquakes and were made available through SMIP. In particular the Whittier Narrows (October, 1987), the Sierra Madre (June, 1991) and the Northridge (January, 1994) earthquakes were considered in the studies reported here. The seismic performance of steel moment-framed buildings has been of particular interest after the 1994 Northridge earthquake because brittle fractures were discovered at the beam-column connection. The Eigensystem Realization Algorithm with Data Correlation (ERA/DC) and Observer/Kalman filter Identification (OKID) were used in these studies for system identification purposes. The identified modal properties of the structure were compared and verified with the spectral analysis of the response of the structure excited by three different earthquakes.

58 GEOSCIENCES↗

The impact of simplified window and exhaust fan assumptions on indoor air quality in multifamily buildings

In residential buildings, the indoor air quality can be significantly affected by ventilation measures initiated by occupants, including the operation of windows and in-unit exhaust fans in kitchens and bathrooms. Many simulations simplify these factors by disregarding window opening behaviors and using fixed schedules for exhaust fan operation across all residential units. To estimate the impact of these simplifications in the U.S. context, this study used coupled CONTAM and EnergyPlus models to simulate airflow and contaminant transport in multifamily buildings. The coupled models parametrically varied climate zone, building airtightness, and mechanical ventilation system types. The study conducted a sensitivity analysis on two key occupant behaviors: (1) operating kitchen and bathroom exhausts on different schedules in individual dwelling units, and (2) scheduling open windows on ground and top floors. The simplified assumptions (i.e. uniform in-unit exhaust fan operation and window operation) had a minimal impact on inter-unit air flow and contaminant transport simulations across a broad range of building air leakage and mechanical ventilation system types. These findings suggest that for buildings with tight construction it is reasonable for most modelling and simulation efforts to ignore the effects of non-uniform exhaust fan operation and window opening.

Occupant behavior↗

Development of a metamodelling framework for building energy models with application to fifth-generation district heating and cooling networks

Fully defined physics-based building energy models can accurately represent building systems; however, generating models based on high-level parameters is time consuming and simulation time of complex models can be slow. This article discusses the development of a Metamodelling Framework to create metamodels from a building energy modelling dataset. The framework generates metamodels using either linear regression, random forests, or support vector regressions. A fifth-generation district heating and cooling system analysis use case was used to motivate the development of the framework. The use case required quick and accurate representations of annual building loads reported hourly. Typical annual building modelling approaches can result in a runtime of 10 min. The metamodels runtime was reduced to less than 10 s to load and run an annual simulation with user-defined covariates. The results of the metamodel performance and an abbreviated topology analysis based on the motivating use case will be presented.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Surrogate modelling for urban building energy simulation based on the bidirectional long short-term memory model

Here, the urban microclimate is essential for accurate simulation-based urban building energy modelling (UBEM). However, a high spatial-resolution microclimate can increase the computational resources demands of UBEM. Surrogate modelling is one of the promising approaches for fast UBEM. This study proposes a bidirectional Long Short-Term Memory (LSTM)-based approach for simulation-based UBEM surrogate modelling. The estimations are aggregated into census tracts using total building floor area. A case study using UBEM to estimate annual hourly building energy use and anthropogenic heat from all existing buildings in Los Angeles County found that most of the surrogate models can complete the annual hourly simulation within 90 minutes with a normalized mean absolute error lower than 10%, and that the bidirectional LSTM outperforms the standard LSTM in accuracy. This study demonstrates the advantages of bidirectional RNN architecture in building energy surrogate modelling and is expected to promote long-term and high-resolution UBEM with detailed microclimates.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

On-policy learning-based deep reinforcement learning assessment for building control efficiency and stability

Artificial intelligence technologies have emerged as a game changer not only in specific applications such as image recognition and machine translation but also in many scientific domains. In particular, as deep reinforcement learning (DRL) has shown great success in complex control problems, DRL-based control has been considered as a potential solution to efficiently control and manage building systems. However, broad assessment of DRL-based building control is still required to characterize their pros and cons in comparison with conventional building control methods (e.g., rule-based feedback controls). In this paper, we assessed DRL-based controls with on-policy learning-based algorithms and continuous control actions for cooling control of large office buildings in the summer season to minimize whole-building energy use and occupant discomfort. We compared DRL-based control methods with two baseline control methods: (1) a pre-determined schedule with supply temperature and static pressure setpoints, and (2) advanced reset method that adjusts setpoints based on heuristic rules, i.e., ASHRAE Guideline 36. We also tested the DRL algorithms to evaluate their performances in multiple climate locations. We found that DRL-based control methods outperformed the baseline control methods in terms of energy savings while maintaining a thermal comfort. DRL reduced energy use between ~4%–22% on average compared to the baseline methods, depending on climate location. We also evaluated DRL-based control in terms of control stability and showed that DRL-based methods should address the span of hardware lifetimes in practical operations.

control stability↗