Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “affordability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

Accurate and efficient predictions of keyhole dynamics in laser materials processing using machine learning-aided simulations

The keyhole phenomenon has been widely observed in laser materials processing, including laser welding, remelting, cladding, drilling, and additive manufacturing. Keyhole-induced defects, primarily pores, dramatically affect the performance of final products, impeding the broad use of these laser-based technologies. The formation of these pores is typically associated with the dynamic behavior of the keyhole. So far, the accurate characterization and prediction of keyhole features, particularly keyhole depth, as a function of time, has been a challenging task. In situ characterization of keyhole dynamic behavior using the synchrotron X-ray technique is informative but complicated and expensive. Current simulations are generally hindered by their poor accuracy and generalization abilities in predicting keyhole depths due to the lack of accurate laser absorptance data. In this study, we develop a machine learning-aided simulation method that accurately predicts keyhole dynamics, especially in keyhole depth fluctuations, over a wide range of processing parameters. In two case studies involving titanium and aluminum alloys, we achieve keyhole depth prediction with a mean absolute percentage error of 10 %, surpassing those simulated using the ray-tracing method with an error margin of 30 %, while also reducing computational time. This exceptional fidelity and efficiency empower our model to serve as a cost-effective alternative to synchrotron experiments. Our machine learning-aided simulation method is affordable and readily deployable for a large variety of materials, opening new doors to eliminate or reduce defects for a wide range of laser materials processing techniques.

Computational fluid dynamics↗

A multiscale combustion model formulation for NO x predictions in hydrogen enriched jet flames

Here the present paper investigates the role of combustion models and kinetic mechanisms on the prediction of NO x emissions in a turbulent combustion system where conventional and unconventional routes are equally important for NO x formation. To this end, a lab-scale combustion system working in Moderate and Intense Low-oxygen Dilution (MILD) conditions, namely the Adelaide Jet in Hot Co-flow (JHC) burner, is targeted. The Eddy Dissipation Concept (EDC) and the Partially-Stirred Reactor (PaSR) models are used for turbulence-chemistry interactions. The KEE and GRI2.11 chemical mechanisms are employed. The results show that the choice of the combustion model has a higher impact than the selection of the kinetic mechanism for the investigated cases, indicating that biases in the turbulent reactive flow closure are as important, if not more, as the level of the accuracy of the chemical scheme employed. Moreover, the sensitivity of the NO emissions to the uncertain kinetic parameters of the rate-limiting reactions of the NNH pathway is found to be significant when a detailed kinetic mechanism is used. An engineering modification of the PaSR combustion model is proposed to account for the different chemical time scales of fuel oxidation reactions and NO x formation pathways. It shows an equivalent impact on the emissions of NO than the uncertainty in the NNH pathway kinetics. At the cost of introducing a negligible mass imbalance, the adjustment leads to improved predictions of NO. The investigation establishes a possibility for the engineering modeling of NO formation in turbulent flames with a finite-rate chemistry combustion model that can incorporate a detailed mechanism at an affordable computational cost.

08 HYDROGEN↗

Influences on hydrogen production at a wind farm

If an affordable infrastructure for low-carbon-intensity hydrogen can be developed, then hydrogen is expected to become a key factor in decarbonizing the atmosphere. This research focuses on factors an existing wind farm operator would consider when weighing participating in the electricity market, the hydrogen market, or both. The solutions depend on the state of technology, which is changing rapidly, the local market structures, the local natural resources, and the local pre-existing infrastructure. Consequently, this investigation used an assessment approach that examined the variation of net present value. The investigation identified profitability conditions under three different scenarios: 1) Make and sell what makes economic sense at the time of production, 2) Use electrolyzer and fuel cell to consume power from the grid at times of low net demand and to produce electricity at times of high net demand, 3) Same as #2 but also market hydrogen directly when profitable.

08 HYDROGEN↗

Iron-sandstone synergy: Advancing in-situ hydrogen production from natural gas via electromagnetic heating

Here, to address the escalating demands for decarbonization in the petroleum industry, a carbon-zero technology, known as in-situ hydrogen (H 2 ) production via electromagnetic (EM)-assisted catalytic heating, has recently been proposed for generating and extracting clean H 2 directly from petroleum reservoirs. Although preliminary techno-economic analyses show significant potential of this emerging technology for clean and affordable hydrogen, the fundamentals of natural gas conversion to H 2 in the presence of reservoir rocks are poorly understood. In this study, we explore the synergy between sandstone and artificial iron-based catalysts in enhancing in-situ H 2 production from methane (CH 4 ) cracking under EM irradiation. The dynamic behaviors of sandstone under EM heating are comprehensively investigated, including its thermal behaviors, thermal runaway (TR) phenomenon, gas generation during TR, and energy consumption. We found that sandstone demonstrates an evident natural catalytic effect for promoting CH 4 conversion to H 2 , enabling H 2 production starting at about 394 °C. The natural catalytic role of iron minerals in sandstone is elucidated using various advanced characterization techniques. Remarkably, when adding iron catalysts into the sandstone, the highest H 2 concentration and CH 4 conversion reaches 91 mol.% and 80%, respectively, at a temperature of 666 °C, while they are 50 mol.% and 35%, respectively, for the sample consisting of iron catalysts and quartz at the same level of temperature. This result indicates a strong iron-sandstone synergy and a potential to stimulate H 2 production by leveraging this synergy. Throughout the experimental process, the generation of carbon oxides (CO and CO 2 ) is negligible. These findings pave a pathway towards future pilot for carbon-zero in-situ H 2 production from sandstone gas reservoirs.

03 NATURAL GAS↗

Multicycle large-eddy simulations of a direct-injection hydrogen-fueled optical engine

Hydrogen (H 2 ) is a carbon-free chemical energy carrier and one promising solution for achieving effective decarbonization of the transportation sector, particularly for internal combustion engines (ICEs). With a focus on ICEs, and compared to port-fuel injection, direct injection (DI) of gaseous H 2 during the compression stroke offers potential advantages, which include backfire avoidance and reduction of preignition occurrence. In these last two decades, much research, experimental and numerical, has been devoted to understanding H 2 's mixing and combustion processes in ICEs. Computational fluid dynamics modeling efforts commonly rely on unsteady Reynolds-averaged Navier Stokes (URANS) turbulence frameworks, mostly due to their computational affordability. However, many authors have pointed out the opportunity to perform large-eddy simulations (LESs) to investigate the cyclic variability of H 2 engines and assess potential advantages of using LES in place of URANS, especially for lean operation. This study addresses this knowledge gap and presents a computational fluid dynamics (CFD) study of the H 2 DI process in an optical engine operating at relatively low tumble conditions, using multicycle LESs. In conclusion, the manuscript presents a thorough validation of the results against experimental data available from the literature as well as direct comparison with URANS, demonstrating the feasibility of multicycle LESs for CFD modeling of DI H 2 -fueled ICEs.

Direct injection↗

Developing Science-based fueling protocols for 250-bar hydrogen tanks onboard hydrogen ferries: Experiments and modeling

Combined modeling and experimental studies are reported of the fueling of a large (28 kg capacity) 250-bar Type IV hydrogen tank of the type being deployed on early hydrogen ferries, such as the MV Sea Change. The primary goal was to determine how such tanks can be successfully fueled with hydrogen (state of charge greater than 97%) within 45 minutes without exceeding the 82 °C temperature limit for such tanks. The modeling studies show that a gas injector is needed to avoid thermal stratification during hydrogen fueling which can result in potential hot spots. Empirically, precooling of the hydrogen to 0 °C was found to be needed in some of the cases examined, as ambient conditions greatly affected the need for a precooling to achieve the 45-minute fill time desired by end users. The experimental results afforded a calibration of the engineering model SOFIL for these large 250-bar tanks, which now enables using SOFIL to predict volume-averaged hydrogen fueling temperatures to an accuracy of ±2.7°C for these tanks. The model can therefore be used to evaluate potential scenarios for development of a standardized fueling methodology for ferries utilizing large Type-IV tanks.

08 HYDROGEN↗

Shear assisted processing and extrusion of enhanced strength aluminum alloy tubing

Hollow extrusions are used in many industries to make strong, lightweight, and affordable structures. Shear Assisted Processing and Extrusion (ShAPE) enables the extrusion of many alloys, often with noteworthy properties. In this investigation, ShAPE was used to extrude 1 and 2 mm wall tubes of aluminum alloy 6063 measuring 12 mm in diameter at extrusion speeds up to 3.8 m/min. This speed is 10 and 15 times faster than has been reported for any alloy using ShAPE and friction stir back extrusion, respectively. Increasing the extrusion speed from 0.7 to 3.8 m/s resulted in using 68% less process energy at steady state. Microstructural analysis and tensile testing were performed on as-extruded tubes and tubes with a direct T5 heat treatment. Grain refinement from 65 µm to below 20 µm was observed. Growth of macroscale Mg 2 Si strengthening precipitates was not observed. ShAPE processing resulted in recrystallization, and extrusion speed was shown to influence final extrudate texture. Here, transmission electron microscopy analysis revealed that the as-extruded microstructure was free of nanoscale ß" strengthening precipitates. Nanoscale ß" was prominent in direct-aged (T5) ShAPE tubes, similar to a slightly over-aged conventional T6 microstructure. As-extruded tubes had ultimate tensile strengths on par with conventional T5 extrusions and approximately double the total elongation. Tubes that underwent a T5 heat treatment had yield and ultimate strengths averaging 198 and 234 MPa, respectively, with an average total elongation of 11%. The tensile test results are comparable to a conventional T6 heat treatment, but without the solutionization heat treatment step. Mechanical properties either remained flat or improved with increased extrusion speed, which suggests that ShAPE can be scaled up to an industrial process to create energy- and economically efficient high-strength extrusions.

36 MATERIALS SCIENCE↗

What do Patients Want From Their Radiation Oncologist? Initial Results From a Prospective Trial

Purpose: To assess patients' initial physician preferences using a newly developed instrument. Methods and Materials: A total of 182 patients with a primary diagnosis of prostate, breast, or lung cancer referred for consultation to University of Pittsburgh Cancer Institute Department of Radiation Oncology enrolled in our institutional review board-approved protocol. All patients completed patient preference instrument surveys before meeting their radiation oncologist. Survey responses to 10 statements were categorized into three groups (agree, neutral, or disagree), and the association of survey responses by cancer site was tested with chi-squared tests. Results: Ninety-nine percent of all patients preferred to be addressed by their first name in encounters with their radiation oncologist. There were significant associations of Item 3 (hand holding) with gender (p = 0.039) and education (p = 0.028). The responses to Item 5, a statement that patients would feel uncomfortable if the radiation oncologist offered to hug them at the end of treatment, was significantly associated with disease site (p < 0.0001). Further analysis was performed for Item 5 and revealed that the male lung cancer patients had a much higher rate of disagreement with Item 5 compared with prostate cancer patients (37% vs. 18%). Conclusions: Results of this study may afford greater insight and foster better understanding of what patients want from their radiation oncologist. For breast, lung, and prostate cancer patients, initial preferences for their radiation oncologist are generally similar, according to this tool. However, there are important difference among cancer sites (and gender) regarding physical contact at the end of treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Retrospective IMRT Dose Reconstruction Based on Cone-Beam CT and MLC Log-File

Purpose: Head-and-neck (HN) cone-beam computed tomography (CBCT) can be exploited to probe the IMRT dose delivered to a patient taking into account the interfraction anatomic variation and any potential inaccuracy in the IMRT delivery. The aim of this work is to reconstruct the intensity-modulated radiation therapy dose delivered to an HN patient using the CBCT and multileaf collimator (MLC) log-files. Methods and Materials: A cylindrical CT phantom was used for calibrating the electron density and validating the procedures of the dose reconstruction. Five HN patients were chosen, and for each patient, CBCTs were performed on three separate fractions spaced every 2 weeks starting from the first fraction. The respective MLC log-files were retrieved and converted into fluence maps. The dose was then reconstructed on the corresponding CBCT with the regenerated fluence maps. The reconstructed dose distribution, dosimetric endpoints, and DVHs were compared with that of the treatment plan. Results: Phantom study showed that HN CBCT can be directly used for dose reconstruction. For most treatment sessions, the CBCT-based dose reconstructions yielded DVHs of the targets close (within 3%) to that of the original treatment plans. However, dosimetric changes (within 10%) due to anatomic variations caused by setup inaccuracy, organ deformation, tumour shrinkage, or weight loss (or a combination of these) were observed for the critical organs. Conclusions: The methodology we established affords an objective dosimetric basis for the clinical decision on whether a replanning is necessary during the course of treatment and provides a valuable platform for adaptive therapy in future.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multicriteria Optimization in Intensity-Modulated Radiation Therapy Treatment Planning for Locally Advanced Cancer of the Pancreatic Head

Purpose: Intensity-modulated radiation therapy (IMRT) affords the potential to decrease radiation therapy-associated toxicity by creating highly conformal dose distributions. However, the inverse planning process can create a suboptimal plan despite meeting all constraints. Multicriteria optimization (MCO) may reduce the time-consuming iteration loop necessary to develop a satisfactory plan while providing information regarding trade-offs between different treatment planning goals. In this exploratory study, we examine the feasibility and utility of MCO in physician plan selection in patients with locally advanced pancreatic cancer (LAPC). Methods and Materials: The first 10 consecutive patients with LAPC treated with IMRT were evaluated. A database of plans (Pareto surface) was created that met the inverse planning goals. The physician then navigated to an 'optimal' plan from the point on the Pareto surface at which kidney dose was minimized. Results: Pareto surfaces were created for all 10 patients. A physician was able to select a plan from the Pareto surface within 10 minutes for all cases. Compared with the original (treated) IMRT plans, the plan selected from the Pareto surface had a lower stomach mean dose in 9 of 10 patients, although often at the expense of higher kidney dose than with the treated plan. Conclusion: The MCO is feasible in patients with LAPC and allows the physician to choose a satisfactory plan quickly. Generally, when given the opportunity, the physician will choose a plan with a lower stomach dose. The MCO enables a physician to provide greater active clinical input into the IMRT planning process.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fractionated Conformal Radiotherapy in the Management of Cavernous Sinus Meningiomas: Long-Term Functional Outcome and Tumor Control at a Single Institution

Purpose: To evaluate long-term outcome of cavernous sinus meningioma (CSM) treated with fractionated conformal radiotherapy (FCR). Patients and Methods: Fifty-three patients with CSMs (16 men [30.2%], 37 women [69.8%], aged 53 {+-} 13.0 years [mean {+-} SD]) were treated by FCR. In 28 patients (52.8%) FCR was performed as first-line treatment and in 25 patients (47.2%) as adjuvant treatment. All patients received FCR with a dose of 52.9 {+-} 1.8 Gy in 29.4 {+-} 1.0 fractions over 6 weeks. Dose per fraction was 1.9 {+-} 0.1 Gy. Radiotherapy was delivered stereotactically in 47 cases (88.7%) and conformally in 6 (11.3%) Results: The median follow-up was 6.9 years (range, 3-19 years). According to Sekhar's classification, 19 patients (35.8%) were Grade 1-2, 30 patients (56.6%) were Grade 3-4, and 4 patients (7.6%) were Grade 5. Pretreatment tumor volume was determined in 46 patients, and tumor volume was 12.6 {+-} 8.2 cm{sup 3}. In these patients, the distance between tumor and optic apparatus was 1.62 {+-} 1.2 mm. Actuarial 5- and 10-year progression-free survival rates were 98.1% and 95.8%, respectively. Clinical improvement was observed in 31 patients (58.5%), and 20 patients (37.7%) remained unchanged. Radiologic response was observed in 18 patients (30.2%), and 35 patients (66.0%) showed stable lesions. Two patients (3.8%) showed tumor progression during follow-up. Transient morbidity was observed in 3 patients (5.7%) and permanent morbidity in 1 (1.9%). Conclusion: Fractionated conformal radiotherapy affords satisfactory long-term tumor control and low treatment morbidity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Azidothymidine Enhances Fluorodeoxyuridine-Mediated Radiosensitization

Purpose: To examine the role of DNA repair and altered thymidine analogues in altering the response to radiation during thymidine deprivation. Methods and Materials: Mismatch repair-deficient and -proficient cell lines HEC59 and HC-2.4 were treated with fluorodeoxyuridine (FUdR), azidothymidine (AZT), and irradiation either alone or in combination, and outcomes of clonogenic survival and cell-cycle distributions were determined. Results: Survival outcomes for all treatments were similar for both cell lines, suggesting that hMSH2 does not significantly influence thymidine deprivation toxicity or radiosensitization. The chain-terminating thymidine analogue AZT increased the toxicity of FUdR and increased DNA fragmentation. The combination of FUdR and AZT afforded greater radiosensitization than either drug alone. Drug enhancement ratios, the degree of excess radiation-induced cell death in drug-treated cultures compared with radiation alone for HEC59, were 1.2, 1.4, and 1.8 for AZT, FUdR, and the combination, respectively. Enhancement ratios for HC-2.4 were 1.3, 1.5, and 1.8 for AZT, FUdR, and the combination, respectively. Conclusion: Azidothymidine, a chain-terminating thymidine analogue, can enhance the radiosensitizing affects of thymidine deprivation. Deoxyribonucleic acid strand breaks may play an important role in the mechanism of thymidine deprivation-induced radiosensitization.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Fractionated Conformal Radiotherapy for Management of Optic Nerve Sheath Meningiomas: Long-Term Outcomes of Tumor Control and Visual Function at a Single Institution

Purpose: To provide the long-term outcomes of patients treated with fractionated conformal radiotherapy (FCRT) for presumed optic nerve sheath meningiomas (ONSMs). Patients and Methods: Between 1995 and 2002, 9 patients with a presumed ONSM were treated with FCRT at our institution. The indications for FCRT were significant visual dysfunction at presentation, progression of visual dysfunction during a period of observation, tumor growth documented by sequential imaging, or a combination of these findings. In 2 patients, FCRT was performed as adjuvant therapy, and in 7, it was the initial and primary treatment. Results: Of the 9 patients, 6 were women and 3 were men, with a mean age of 47 years. All 9 patients had evidence of optic nerve dysfunction in the affected eye, characterized by reduced visual acuity, a visual field defect, and a relative afferent pupillary defect. In addition, 2 patients had proptosis and 1 had diplopia. The mean follow-up period was 98 {+-} 31.7 months (median, 90; range, 61-151). After FCRT, the visual function improved in the 7 patients who had undergone FCRT as the primary treatment. However, 2 patients who were blind in their affected eye at FCRT remained blind. In 4 of the 7 patients with improvement, the improvement was documented within 1-3 months after FCRT. The tumor control rate was 100%. Proptosis and diplopia also regressed in 100% of patients. At 2 years after FCRT, 1 patient had developed radiation retinopathy. Conclusion: The results of our study have shown that FCRT is a safe and effective treatment of ONSMs, affording satisfactory long-term tumor control, good functional outcome, and low treatment morbidity. FCRT should be considered the treatment of choice for patients with presumed ONSMs for whom the treatment has been deemed appropriate.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Proton Beam Therapy and Accountable Care: The Challenges Ahead

Purpose: Proton beam therapy (PBT) centers have drawn increasing public scrutiny for their high cost. The behavior of such facilities is likely to change under the Affordable Care Act. We modeled how accountable care reform may affect the financial standing of PBT centers and their incentives to treat complex patient cases. Methods and Materials: We used operational data and publicly listed Medicare rates to model the relationship between financial metrics for PBT center performance and case mix (defined as the percentage of complex cases, such as pediatric central nervous system tumors). Financial metrics included total daily revenues and debt coverage (daily revenues − daily debt payments). Fee-for-service (FFS) and accountable care (ACO) reimbursement scenarios were modeled. Sensitivity analyses were performed around the room time required to treat noncomplex cases: simple (30 minutes), prostate (24 minutes), and short prostate (15 minutes). Sensitivity analyses were also performed for total machine operating time (14, 16, and 18 h/d). Results: Reimbursement under ACOs could reduce daily revenues in PBT centers by up to 32%. The incremental revenue gained by replacing 1 complex case with noncomplex cases was lowest for simple cases and highest for short prostate cases. ACO rates reduced this incremental incentive by 53.2% for simple cases and 41.7% for short prostate cases. To cover daily debt payments after ACO rates were imposed, 26% fewer complex patients were allowable at varying capital costs and interest rates. Only facilities with total machine operating times of 18 hours per day would cover debt payments in all scenarios. Conclusions: Debt-financed PBT centers will face steep challenges to remain financially viable after ACO implementation. Paradoxically, reduced reimbursement for noncomplex cases will require PBT centers to treat more such cases over cases for which PBT has demonstrated superior outcomes. Relative losses will be highest for those facilities focused primarily on treating noncomplex cases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Extended (5-year) Outcomes of Accelerated Partial Breast Irradiation Using MammoSite Balloon Brachytherapy: Patterns of Failure, Patient Selection, and Dosimetric Correlates for Late Toxicity

Purpose: Accelerated partial breast irradiation (APBI) with balloon and catheter-based brachytherapy has gained increasing popularity in recent years and is the subject of ongoing phase III trials. Initial data suggest promising local control and cosmetic results in appropriately selected patients. Long-term data continue to evolve but are limited outside of the context of the American Society of Breast Surgeons Registry Trial. Methods and Materials: A retrospective review of 157 patients completing APBI after breast-conserving surgery and axillary staging via high-dose-rate {sup 192}Ir brachytherapy from June 2002 to December 2007 was made. APBI was delivered with a single-lumen MammoSite balloon-based applicator to a median dose of 34 Gy in 10 fractions over a 5-day period. Tumor coverage and critical organ dosimetry were retrospectively collected on the basis of computed tomography completed for conformance and symmetry. Results: At a median follow-up time of 5.5 years (range, 0-10.0 years), the 5-year and 7-year actuarial incidences of ipsilateral breast control were 98%/98%, of nodal control 99%/98%, and of distant control 99%/99%, respectively. The crude rate of ipsilateral breast recurrence was 2.5% (n=4); of nodal failure, 1.9% (n=3); and of distant failure, 0.6% (n=1). The 5-year and 7-year actuarial overall survival rates were 89%/86%, with breast cancer–specific survival of 100%/99%, respectively. Good to excellent cosmetic outcomes were achieved in 93.4% of patients. Telangiectasia developed in 27% of patients, with 1-year, 3-year, and 5-year actuarial incidence of 7%/24%/33%; skin dose >100% significantly predicted for the development of telangiectasia (50% vs 14%, P<.0001). Conclusions: Long-term single-institution outcomes suggest excellent tumor control, breast cosmesis, and minimal late toxicity. Skin toxicity is a function of skin dose, which may be ameliorated with dosimetric optimization afforded by newer multicatheter brachytherapy applicators and a more rigorous skin dose constraint of ≤100%.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Nonisocentric Treatment Strategy for Breast Radiation Therapy: A Proof of Concept Study

Purpose: To propose a nonisocentric treatment strategy as a special form of station parameter optimized radiation therapy, to improve sparing of critical structures while preserving target coverage in breast radiation therapy. Methods and Materials: To minimize the volume of exposed lung and heart in breast irradiation, we propose a novel nonisocentric treatment scheme by strategically placing nonconverging beams with multiple isocenters. As its name suggests, the central axes of these beams do not intersect at a single isocenter as in conventional breast treatment planning. Rather, the isocenter locations and beam directions are carefully selected, in that each beam is only responsible for a certain subvolume of the target, so as to minimize the volume of irradiated normal tissue. When put together, the beams will provide an adequate coverage of the target and expose only a minimal amount of normal tissue to radiation. We apply the nonisocentric planning technique to 2 previously treated clinical cases (breast and chest wall). Results: The proposed nonisocentric technique substantially improved sparing of the ipsilateral lung. Compared with conventional isocentric plans using 2 tangential beams, the mean lung dose was reduced by 38% and 50% using the proposed technique, and the volume of the ipsilateral lung receiving ≥20 Gy was reduced by a factor of approximately 2 and 3 for the breast and chest wall cases, respectively. The improvement in lung sparing is even greater compared with volumetric modulated arc therapy. Conclusions: A nonisocentric implementation of station parameter optimized radiation therapy has been proposed for breast radiation therapy. The new treatment scheme overcomes the limitations of existing approaches and affords a useful tool for conformal breast radiation therapy, especially in cases with extreme chest wall curvature.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Theoretical Benefits of Dynamic Collimation in Pencil Beam Scanning Proton Therapy for Brain Tumors: Dosimetric and Radiobiological Metrics

Purpose: To quantify the dosimetric benefit of using a dynamic collimation system (DCS) for penumbra reduction during the treatment of brain tumors by pencil beam scanning proton therapy (PBS PT). Methods and Materials: Collimated and uncollimated brain treatment plans were created for 5 patients previously treated with PBS PT and retrospectively enrolled in an institutional review board–approved study. The in-house treatment planning system, RDX, was used to generate the plans because it is capable of modeling both collimated and uncollimated beamlets. The clinically delivered plans were reproduced with uncollimated plans in terms of target coverage and organ at risk (OAR) sparing to ensure a clinically relevant starting point, and collimated plans were generated to improve the OAR sparing while maintaining target coverage. Physical and biological comparison metrics, such as dose distribution conformity, mean and maximum doses, normal tissue complication probability, and risk of secondary brain cancer, were used to evaluate the plans. Results: The DCS systematically improved the dose distribution conformity while preserving the target coverage. The average reduction of the mean dose to the 10-mm ring surrounding the target and the healthy brain were 13.7% (95% confidence interval [CI] 11.6%-15.7%; P<.0001) and 25.1% (95% CI 16.8%-33.4%; P<.001), respectively. This yielded an average reduction of 24.8% (95% CI 0.8%-48.8%; P<.05) for the brain necrosis normal tissue complication probability using the Flickinger model, and 25.1% (95% CI 16.8%-33.4%; P<.001) for the risk of secondary brain cancer. A general improvement of the OAR sparing was also observed. Conclusion: The lateral penumbra reduction afforded by the DCS increases the normal tissue sparing capabilities of PBS PT for brain cancer treatment while preserving target coverage.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impact of Insurance Status on Radiation Treatment Modality Selection Among Potential Candidates for Prostate, Breast, or Gynecologic Brachytherapy

Purpose: The Patient Protection and Affordable Care Act looks to expand both private and Medicaid insurance. To evaluate how these changes may affect the field of radiation oncology, we evaluated the association of insurance status with the use of brachytherapy in cancers for which this treatment technique is used. Methods and Materials: A total of 190,467 patients met the inclusion criteria, of whom 95,292 (50.0%) had breast cancer, 61,096 (32.1%) had prostate cancer, 28,194 (14.8%) had endometrial cancer, and 5885 (3.1%) had cervical cancer. A multivariate logistic regression model was used to determine the association between insurance status and receipt of brachytherapy among patients treated definitively for prostate and cervical cancer or postoperatively for breast and endometrial cancer. Results: The rates of non-Medicaid insurance were 49.9% (cervical), 85.3% (endometrial), 87.4% (breast), and 90.9% (prostate) (P<.001). In a logistic regression, patients who received radiation therapy were less likely to receive brachytherapy if they had Medicaid coverage (odds ratio [OR] 0.57, 95% confidence interval [CI] 0.53-0.61, P<.001) or did not have insurance coverage (OR 0.50, 95% CI 0.45-0.56, P<.001) compared with those with non-Medicaid insurance. On subset analysis, patients with Medicaid coverage or without insurance coverage were significantly less likely to receive brachytherapy than were those with non-Medicaid insurance for all 4 sites, except for patients with endometrial cancer. Conclusions: Despite being a cost-effective treatment modality, brachytherapy is less often used in the definitive or postoperative management of cancer in patients with Medicaid coverage or without insurance. Upcoming health policy changes resulting in the expansion of private insurance and Medicaid will likely increase access to and demand for brachytherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗