Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Water System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

Geospatial Capabilities to Couple Hazard and Social Vulnerability Data in Water Distribution Criticality Analysis

A resilience analysis of a water distribution system is greatly enhanced by the integration of up-to-date geospatial data describing the water system, hazards, and surrounding community. The Water Network Tool for Resilience (WNTR), an open-source Python package designed to simulate and analyze the resilience of water distribution systems, was recently updated to incorporate geographic information system (GIS) data into the resilience analysis. This paper describes the GIS capabilities and includes a case study using the drinking water distribution system model for a large city in Pennsylvania. The case study focuses on potential pipe damage from landslides and on pipes that are particularly difficult to repair. The analysis couples data on hazards, social vulnerability, and the location of emergency services to identify and prioritize high-impact critical infrastructure for mitigation. Results demonstrate that pipes can be prioritized for mitigation based on water shortage and vulnerable populations that are affected. In conclusion, the methods can be adopted for general use and are available as part of the WNTR software.

GIS, landslide↗

Cooling process and system for dry cooling power plants

A seasonal process that captures stores and uses water in an ambient temperature-dependent manner to improve the efficiency of a natural gas power plant, comprising: (a) providing a natural gas power plant, the natural gas power plant having a flue gas stream, a cooling tower, and a gas turbine; (b) providing a water collection system; (c) providing a water storage facility; wherein the flue gas stream comprises uncondensed water vapor; wherein the water collection system is operably connected to the flue gas stream and the flue gas stream is directed to flow, at least in part, into the water collection system; wherein the water collection system is operably connected to the water storage facility; wherein the water storage facility is operably connected to the cooling tower and the water storage facility is operably connected to the gas turbine; wherein the process comprises the following steps of condensing flue gas water or using water that has been condensed from the flue gas stream based on outdoor ambient dry bulb temperature: (I) Only condensing water from the flue gas stream to produce a condensed water stream if outdoor ambient dry bulb temperature is less than 85° F.; (II) Only using condensed water to spray cool the cooling tower if outdoor ambient dry bulb temperature is at least 85° F.; (III) Only using condensed water to fog cool the gas turbine if outdoor ambient dry bulb temperature is at least 55° F.; wherein condensed water that is not immediately used to cool the cooling tower or to fog cool the gas turbine is stored in the water storage facility; and wherein the process uses a total amount of water on an annual basis to cool the cooling tower and to fog cool the gas turbine that does not exceed the annual amount of water condensed from the flue gas stream. Optionally, the process has a cooling tower that is a dry cooling tower and condensed water is used to spray cool the dry cooling tower, or the cooling tower is a wet cooling tower, or the cooling tower is a hybrid wet-dry cooling tower. The process may further comprise a water collection system having a three stage desiccant cycle and a calcium chloride desiccant that recovers at least about 60 wt % of the water from the flue gas, operates at or above ambient pressure or comprises plastic piping or plastic vessels. Or the process may further comprise using a water collection system having at least one direct contact condensing column that recovers at least about 60 wt % of the water from the flue gas, operates at or above ambient pressure or comprises plastic piping or plastic vessels. Or the process may further comprise using a water collection system having at least one direct contact condenser and a rotating wheel heat exchanger that recovers at least about 60 wt % of the water from the flue gas, operates at or above ambient pressure, or further comprises plastic piping or plastic vessels. The coefficient of performance for the cooling process is optionally at least 2.0.

Srinivas, Girish↗

A System of Agents for Supporting Optimization and Control of a Connected Community

The residential sector consumes a significant portion of the electricity sold in the United States. Above 60% of the energy used in the sector is used to operate heating, ventilation, and air conditioning (HVAC) systems and water heating (WH) systems. With the increase of intelligence in the grid and the new decision and control options enabled by the Internet of Things; control of these devices can be used to support the grid. Therefore, this article presents a scalable multiagent system for optimizing HVAC and WH systems while maintaining comfort. It allows a utility to orchestrate the shifting of energy from critical periods without direct control, but instead by using a price signal. The architecture, optimization formulation, implementation strategy and results from an implementation project are discussed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Are Water-lean Solvent Systems Viable for Post-Combustion CO 2 Capture?

Here, we present here an overview of water-lean solvents that compares their projected costs and performance to aqueous amine systems, emphasizing critical areas of study needed to evaluate their performance against their water-based brethren. The work presented her focuses on bridging these knowledge gaps. Because the majority of water-lean solvents are still at the lab scale, substantial studies are still needed to model their performance at scale. This presents a significant challenge as eachformulation has different physical and thermodynamic properties and behavior, and quantifying how these different properties manifest themselves in conventional absorber-stripper configurations, or identifying new configurations that are specific for a solvent’s signature behavior. We identify critical areas of study that are needed, and our efforts (e.g. custom infrastructure, molecular models) to predict, measure, and model these behaviors. Such findings are critical for determining the rheology required for heat exchanger design; absorber designs and packing to accommodate solvents with gradient changes (e.g. viscosity, contact angle, surface tension), and stripper configurations without direct steam utilization or water reflux. Another critical area of research need is to understand the molecular structure of the liquid interface and bulk as a function of CO 2 loading, and to assess whether conventional film theories accurately quantify solvent behavior, or if thermodynamic models adequately quantify activity coefficients of ions in solution. We conclude with an assessment of our efforts to aid in bridging the knowledge gaps in understanding water-lean solvents, and suggestions of what is needed to enable large-scale demonstrations to meet the United States Department of Energy’s year 2030 goal.

15 GEOTHERMAL ENERGY↗

System design and analysis of thermal power dispatch systems for boiling water reactors

Nuclear power plants are crucial to meeting net zero emission goals and achieving energy sustainability. Integrating these plants with clean energy technologies such as high-temperature steam electrolysis (HTSE) may improve the efficiency and economic competitiveness of these plants. Here, the current study investigates the design and operation of a thermal power dispatch (TPD) system for coupling boiling water reactors (BWRs) to HTSE plants. The TPD system extracts a portion of the steam from the reactor’s main steam line and transfers its thermal energy to an HTSE plant through a power transport loop. A TPD system for 5 % steam extraction has been designed and the system performance during steady and transient operations has been analyzed. The TPD system dispatched a total of 197 MW thermal energy to the HTSE plant under nominal design conditions. Saturated steam at 7.17 MPa from the BWR plant was condensed and subcooled to a temperature of 168 °C, while a mass flow rate of 91.1 kg/s of superheated steam was dispatched to the HTSE plant. Furthermore, the system performance during transient operation showed a continuous transition from the initial hot standby mode to the nominal power dispatch level. The transient simulation results emphasized the importance of investigating component level performance for the TPD system design. The current results will guide future works on the development of integrated energy systems for hydrogen production or process heat applications.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

IUPAC-NIST Solubility Data Series. 100. Rare Earth Metal Fluorides in Water and Aqueous Systems. Part 1. Scandium Group (Sc, Y, La)

This work presents an assessment of solubility data for rare earth metal fluorides (generally of trivalent metals and of CeF{sub 4}) in water and in aqueous ternary systems. Compilations of all available experimental data are introduced for each rare earth metal fluoride with a corresponding critical evaluation. Every such evaluation contains a collection of all solubility results in water, a selection of suggested solubility data, and a brief discussion of the multicomponent systems. Because the ternary systems were seldom studied more than once, no critical evaluations of such data were possible. Only simple fluorides (no complexes or binary salts) are treated as the input substances in this report. The literature has been covered through the end of 2013.

36 MATERIALS SCIENCE↗

Water-absorbing capacitor system for measuring relative humidity

A method and apparatus using a known water-absorbent polymer as a capacitor which is operated at a dc voltage for measuring relative humidity is presented. When formed as a layer between porous electrically-conductive electrodes and operated in an RC oscillator circuit, the oscillator frequency varies inversely with the partial pressure of the moisture to be measured. In a preferred embodiment, the capacitor is formed from Nafion and is operated at a low dc voltage with a resistor as an RC circuit in an RC oscillator. At the low voltage, the leakage current is proper for oscillation over a satisfactory range. The frequency of oscillation varies in an essentially linear fashion with relative humidity which is represented by the moisture being absorbed into the Nafion. The oscillation frequency is detected by a frequency detector.

Laue, Eric G.↗

Computational fluid dynamics (CFD) in the design of a water-jet-drive system

NASA/Marshall Space Flight Center (MSFC) has an ongoing effort to transfer to industry the technologies developed at MSFC for rocket propulsion systems. The Technology Utilization (TU) Office at MSFC promotes these efforts and accepts requests for assistance from industry. One such solicitation involves a request from North American Marine Jet, Inc. (NAMJ) for assistance in the design of a water-jet-drive system to fill a gap in NAMJ's product line. NAMJ provided MSFC with a baseline axial flow impeller design as well as the relevant working parameters (rpm, flow rate, etc.). This baseline design was analyzed using CFD, and significant deficiencies identified. Four additional analyses were performed involving MSFC changes to the geometric and operational parameters of the baseline case. Subsequently, the impeller was redesigned by NAMJ and analyzed by MSFC. This new configuration performs significantly better than the baseline design. Similar cooperative activities are planned for the design of the jet-drive inlet.

Garcia, Roberto↗

Blowdown Recovery System for Cooling Tower Water Treatment

From 2014-2017, the U.S. General Services Administration's (GSA's) average nationwide water rates increased 41%. Rapidly escalating costs, mandated water-reduction targets, and the fact that an average of 28% of commercial office building water use is associated with heating and cooling led the GSA Green Proving Ground program to select alternative water treatment technologies for in-field validation. This report summarizes the latest alternative water treatment evaluation completed in 2022 - a Blowdown Recovery System for Cooling Tower Water Treatment. This Green Proving Ground program project assessed the performance of an alternative water treatment system provided by Aqualogix for treating cooling tower blowdown at the Lloyd D. George U.S. Courthouse in Las Vegas, Nevada.

13 HYDRO ENERGY↗

Laboratory Evaluation of Gas-Fired Tankless and Storage Water Heater Approaches to Combination Water and Space Heating

Homebuilders are exploring more cost effective combined space and water heating systems (combo systems) with major water heater manufacturers that are offering pre-engineered forced air space heating combo systems. In this project, unlike standardized tests, laboratory tests were conducted that subjected condensing tankless and storage water heater based combo systems to realistic, coincidental space and domestic hot water loads with the following key findings: 1) The tankless combo system maintained more stable DHW and space heating temperatures than the storage combo system. 2) The tankless combo system consistently achieved better daily efficiencies (i.e. 84%-93%) than the storage combo system (i.e. 81%- 91%) when the air handler was sized adequately and adjusted properly to achieve significant condensing operation. When condensing operation was not achieved, both systems performed with lower (i.e. 75%-88%), but similar efficiencies. 3) Air handlers currently packaged with combo systems are not designed to optimize condensing operation. More research is needed to develop air handlers specifically designed for condensing water heaters. 4) System efficiencies greater than 90% were achieved only on days where continual and steady space heating loads were required with significant condensing operation. For days where heating was more intermittent, the system efficiencies fell below 90%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Estimating Biofuel Feedstock Water Footprints Using System Dynamics

Increased biofuel production has prompted concerns about the environmental tradeoffs of biofuels compared to petroleum-based fuels. Biofuel production in general, and feedstock production in particular, is under increased scrutiny. Water footprinting (measuring direct and indirect water use) has been proposed as one measure to evaluate water use in the context of concerns about depleting rural water supplies through activities such as irrigation for large-scale agriculture. Water footprinting literature has often been limited in one or more key aspects: complete assessment across multiple water stocks (e.g., vadose zone, surface, and ground water stocks), geographical resolution of data, consistent representation of many feedstocks, and flexibility to perform scenario analysis. We developed a model called BioSpatial H2O using a system dynamics modeling and database framework. BioSpatial H2O could be used to consistently evaluate the complete water footprints of multiple biomass feedstocks at high geospatial resolutions. BioSpatial H2O has the flexibility to perform simultaneous scenario analysis of current and potential future crops under alternative yield and climate conditions. In this proof-of-concept paper, we modeled corn grain (Zea mays L.) and soybeans (Glycine max) under current conditions as illustrative results. BioSpatial H2O links to a unique database that houses annual spatially explicit climate, soil, and plant physiological data. Parameters from the database are used as inputs to our system dynamics model for estimating annual crop water requirements using daily time steps. Based on our review of the literature, estimated green water footprints are comparable to other modeled results, suggesting that BioSpatial H2O is computationally sound for future scenario analysis. Our modeling framework builds on previous water use analyses to provide a platform for scenario-based assessment. BioSpatial H2O's system dynamics is a flexible and user-friendly interface for on-demand, spatially explicit, water use scenario analysis for many US agricultural crops. Built-in controls permit users to quickly make modifications to the model assumptions, such as those affecting yield, and to see the implications of those results in real time. BioSpatial H2O's dynamic capabilities and adjustable climate data allow for analyses of water use and management scenarios to inform current and potential future bioenergy policies. The model could also be adapted for scenario analysis of alternative climatic conditions and comparison of multiple crops. The results of such an analysis would help identify risks associated with water use competition among feedstocks in certain regions. Results could also inform research and development efforts that seek to reduce water-related risks of biofuel pathways.

09 BIOMASS FUELS↗

SLS Ignition Overpressure-Sound Suppression System Performance Evaluated Against Historical Configurations

During the start-up of a number of launch vehicles that include solid rocket motor (SRM), the ignition transient and acoustic environments are mitigated by the implementation of a water spray system located immediately below the SRM nozzle exit plane (NEP). For NASA’s Space Launch System (SLS), this water system is referred to as the Ignition Overpressure / Sound Suppression (IOP/SS) system. The SLS Induced Environments (IE) technical discipline conducted a comprehensive evaluation of the design and as-tested performance of the IOP/SS water that will operate underneath both Boosters during the Artemis I launch. As part of this evaluation, flow rates and imagery from a number of integrated launch pad / mobile launcher IOP/SS flow tests were studied. Additional insight was leveraged from the Shuttle heritage IOP/SS system that includes data and imagery from a number of Flight Readiness Firings (FRF) and water flow tests. Lastly, the IE study included a qualitive comparison of the Shuttle and SLS systems to the equivalent water flow systems for Titan and Atlas V and determined that the NASA water flow systems are substantially different than those supporting other launch vehicles.

Ignition Overpressure↗

SLS Ignition Overpressure-Sound Suppression System Performance Evaluated Against Historical Configurations

During the start-up of a number of launch vehicles that include solid rocket motor (SRM), the ignition transient and acoustic environments are mitigated by the implementation of a water spray system located immediately below the SRM nozzle exit plane (NEP). For NASA’s Space Launch System (SLS), this water system is referred to as the Ignition Overpressure / Sound Suppression (IOP/SS) system. The SLS Induced Environments (IE) technical discipline conducted a comprehensive evaluation of the design and as-tested performance of the IOP/SS water that will operate underneath both Boosters during the Artemis I launch. As part of this evaluation, flow rates and imagery from a number of integrated launch pad / mobile launcher IOP/SS flow tests were studied. Additional insight was leveraged from the Shuttle heritage IOP/SS system that includes data and imagery from a number of Flight Readiness Firings (FRF) and water flow tests. Lastly, the IE study included a qualitive comparison of the Shuttle and SLS systems to the equivalent water flow systems for Titan and Atlas V and determined that the NASA water flow systems are substantially different than those supporting other launch vehicles.

Ignition Overpressure↗

Hybrid Membrane System for Industrial Water Reuse

This factsheet describes a project that developed and demonstrated a new hybrid system for industrial wastewater treatment that synergistically combines a forward osmosis system with a membrane distillation technology and is powered by waste heat.

Wastewater, wastewater treatment, forward osmosis,↗

Alternative cooling resource for removing the residual heat of reactor

The Recirculated Cooling Water (RCW) system of a Candu reactor is a closed cooling system which delivers demineralized water to coolers and components in the Service Building, the Reactor Building, and the Turbine Building and the recirculated cooling water is designed to be cooled by the Raw Service Water (RSW). During the period of scheduled outage, the RCW system provides cooling water to the heat exchangers of the Shutdown Cooling System (SDCS) in order to remove the residual heat of the reactor, so the RCW heat exchangers have to operate at all times. This makes it very hard to replace the inlet and outlet valves of the RCW heat exchangers because the replacement work requires the isolation of the RCW. A task force was formed to prepare a plan to substitute the recirculated water with the chilled water system in order to cool the SDCS heat exchangers. A verification test conducted in 2007 proved that alternative cooling was possible for the removal of the residual heat of the reactor and in 2008 the replacement of inlet and outlet valves of the RCW heat exchangers for both Wolsong unit 3 and 4 were successfully completed. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Laboratory Evaluation of Gas-Fired Tankless and Storage Water Heater Approaches to Combination Water and Space Heating

Homebuilders are exploring more cost-effective combined space and water heating systems (combo systems) with major water heater manufacturers that are offering pre-engineered forced air space heating combo systems. In this project, unlike standardized tests, laboratory tests were conducted that subjected condensing tankless and storage water heater based combo systems to realistic, coincidental space and domestic hot water loads and found that the tankless combo system maintained more stable DHW and space heating temperatures than the storage combo system, among other key findings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Algal harvesting and water filtration

Systems for algae-based water filtration and algae harvesting are described herein. A flow-way comprises a channel and a divider positioned within the channel that separates the channel into sub-channels. The flow-way further includes an algal growth that grows on a sidewall of the channel and/or the divider. The algal growth can be established in the flow-way by positioning a pre-seeded mesh element within the channel, the pre-seeded mesh element having an algae culture growing thereon prior to positioning the pre-seeded mesh within the channel. A harvesting system comprises a hinged container that includes a straining screen. The hinged container is positioned downstream from a flow-way and receives water from the flow-way. Biomass in the water is strained by and accumulates on the screen. Weight of the accumulated biomass causes the hinged container to tip and deposit the accumulated biomass in a second container.

Davis, Ryan Wesley↗