Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Time resolved imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

Microstructure and Composition of Passivating Interfaces in Silicon Heterojunction Solar Modules Weathered in Different Climates

Sanyo/Panasonic patented silicon heterojunction with intrinsic thin layer (HIT) solar cells in the 1990's, which demonstrated world record photovoltaic (PV) efficiency around 2014 and inspired the newer generations of silicon heterojunction technology (SHJ) as well as the current world record back-contact PV cell designs. The high-quality passivation strategy, utilizing ultra-thin layers of hydrogenated amorphous silicon (a-Si:H), leads to high voltages and long carrier lifetimes, but these qualities may degrade over time as the modules operate outdoors. Here, we investigate local microstructure and composition at the interface layers of cells from HIT modules weathered in a hot, humid climate (Florida, USA) and temperate climate (Colorado, USA) for 10 years. We employ a comprehensive set of high-resolution electron microscopy imaging and spectroscopy to directly resolve structure and composition in these cells down to the nanoscale. We show features such as alignment of the In2O3 transparent conducting oxide and a-Si:H layers on the textured c-Si facets, interfacial oxidation at the a-Si:H/c-Si and In2O3/a-Si:H interfaces, and twinned c-Si resulting from epitaxial growth into the a-Si:H layer. Our results raise potential degradation mechanisms in these outdoor-weathered modules, but the root cause of electrical loss remains uncertain due to the very small changes in aged samples. This study shows that many atomic scale features at the In2O3/a-Si:H/c-Si interfaces are surprisingly robust, and the electrical losses with aging may either be attributed to other pathways or be very sensitive to the subtle chemical and microstructural features observed here.

14 SOLAR ENERGY↗

Ultrafast Electron–Dipole Interactions in TeO- Photodetachment

We present direct experimental evidence of ultrafast coupling between ejected electrons and dynamically forming dipole moments in TeO, captured during the photodetachment of TeO?. By combining high-resolution cryogenic photoelectron spectroscopy with velocity-map imaging, we assess previously inaccessible excited states and resolve rich photoelectron angular distributions (PADs) that encode electron–dipole interactions. Systematic comparison of PADs from femtosecond and picosecond lasers reveals striking deviations from free-electron behavior, representing direct evidence of a transient dipole moment evolving on femtosecond timescales. Quantitative analysis pinpoints the dipole buildup time to be within ~60 fs, providing real-time access to the birth of a molecular dipole field. This work establishes a general approach to probing electron-dipole interactions in their formation stages, offering fundamental insights into the ultrafast interplay between departing electrons and transient polar systems — a process that lies at the core of atomic, molecular, and ultrafast physics.

Yang, Fan↗

Growth of non-polar (11-20) InGaN quantum dots by metal organic vapour phase epitaxy using a two temperature method

Non-polar (11-20) InGaN quantum dots (QDs) were grown by metal organic vapour phase epitaxy. An InGaN epilayer was grown and subjected to a temperature ramp in a nitrogen and ammonia environment before the growth of the GaN capping layer. Uncapped structures with and without the temperature ramp were grown for reference and imaged by atomic force microscopy. Micro-photoluminescence studies reveal the presence of resolution limited peaks with a linewidth of less than ∼500 μeV at 4.2 K. This linewidth is significantly narrower than that of non-polar InGaN quantum dots grown by alternate methods and may be indicative of reduced spectral diffusion. Time resolved photoluminescence studies reveal a mono-exponential exciton decay with a lifetime of 533 ps at 2.70 eV. The excitonic lifetime is more than an order of magnitude shorter than that for previously studied polar quantum dots and suggests the suppression of the internal electric field. Cathodoluminescence studies show the spatial distribution of the quantum dots and resolution limited spectral peaks at 18 K.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Non-gated laser-induced breakdown spectroscopy in bulk water by position-selective detection

Temporal and spatial evolutions of the laser-induced plasma in bulk water are investigated using fast imaging and emission spectroscopic techniques. By tightly focusing a single-pulse nanosecond Nd: YAG laser beam into the bulk water, we generate a strongly expanded plasma with high reproducibility. Such a strong expanding plasma enables us to obtain well-resolved spectral lines by means of position-selective detection; hence, the time-gated detector becomes abdicable. The present results suggest not only a possible non-gated approach for underwater laser-induced breakdown spectroscopy but also give an insight into the plasma generation and expansion in bulk water.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A plano–convex thick-lens velocity map imaging apparatus for direct, high resolution 3D momentum measurements of photoelectrons with ion time-of-flight coincidence

Since their inception, velocity map imaging (VMI) techniques have received continued interest in their expansion from 2D to 3D momentum measurements through either reconstructive or direct methods. Recently, much work has been devoted to the latter of these by relating electron time-of-flight (TOF) to the third momentum component. The challenge is having a timing resolution sufficient to resolve the structure in the narrow (<10 ns) electron TOF spread. Here, we build upon the work in VMI lens design and 3D VMI measurement by using a plano–convex thick-lens (PCTL) VMI in conjunction with an event-driven camera (TPX3CAM) providing TOF information for high resolution 3D electron momentum measurements. We perform simulations to show that, with the addition of a mesh electrode to the thick-lens geometry, the resulting plano–convex electrostatic field extends the detectable electron cutoff energy range while retaining the high resolution. This design also extends the electron TOF range, allowing for a better momentum resolution along this axis. We experimentally demonstrate these capabilities by examining above-threshold ionization in xenon, where the apparatus is shown to collect electrons of energy up to ∼7 eV with a TOF spread of ∼30 ns, both of which are improved compared to a previous work by factors of ∼1.4 and ∼3.75, respectively. Finally, the PCTL-VMI is equipped with a coincident ion TOF spectrometer, which is shown to effectively extract unique 3D momentum distributions for different ionic species in a gas mixture. These techniques have the potential to lend themselves to more advanced measurements involving systems where the electron momentum distributions possess non-trivial symmetries.

Instruments & Instrumentation↗

Spectroscopic investigation of early light emission from anode-initiated surface flashover in vacuum

Time-resolved optical emission spectroscopy is used to explore the early development of anode-initiated flashover in vacuum. An experimental apparatus for collecting flashover self-luminosity is introduced, which enables spatially resolved light collection from regions adjacent to the anode and cathode triple junctions. The emitted light is spectrally and temporally resolved utilizing an imaging spectrograph and a fast electronic shutter camera. The first light detectable from flashovers across both Rexolite and polytetrafluoroethylene (PTFE) insulators begins less than 10 ns prior to the flashover gap's impedance collapse and consists of faint broadband feature in primarily visible wavelengths. This suggests luminosity due to excitation in the solid, possibly occurring as a result of field emitted electrons. In the few nanoseconds leading up to and including the impedance collapse, the broadband spectrum grows in intensity and extends into the UV, eventually accompanied by a few emission lines of the insulator material. This is strong evidence that the early stages of anode-initiated flashover include surface layer breakdown of the insulator, as a contrast from cathode-initiated flashover, which is predominately an above-surface process. Spectra accumulated over longer exposures of PTFE flashovers indicate that, in the first few hundred nanoseconds after the impedance collapse, ions from the insulator material constitute the majority of the emission lines. Later, neutral and ionic metal species from the electrode contribute with similar prominence as well as molecular bands from diatomic carbon. Finally, a comparison is provided of the results of these studies to other spectroscopic investigations of vacuum flashover from the literature.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Microscopy of Electrostatic Field Effect in Novel Quantum Materials (Final Report)

In this DOE Early Career project “Microscopy of Electrostatic Field Effect in Novel Quantum Materials”, the PI’s group explored the nanoscale electronic properties when charge carriers are electrostatically modulated in functional materials. Using a microwave impedance microscope (MIM), the team probed the spatial evolution of local conductivity in various field-effect transistors (FETs) ranging from traditional metal-oxide-semiconductor FETs, sketched oxide-interface FETs, to ferroelectric FETs and electric double-layer transistors (EDLTs). Specifically, the work has led to a deep understanding on the electrical inhomogeneity and conductive edge channels in atomically thin transition metal dichalcogenides and their heterostructures, which is of fundamental importance for their applications in electronics and photonics. The unique sub-surface imaging capability also enables the first-time report of ferroelectric field effect on Ge substrates due to the polarization switching of an epitaxial BaTiO 3 layer, as well as the visualization of sketched nanostructures in the LaAlO 3 /SrTiO 3 interface. Using a cryogenic MIM, the local channel conductance in ion-gel-gated oxide EDLTs has been successfully imaged, resolving a major challenge in the EDLT research to study electronic fluctuations in the devices. Finally, a new tuning-fork-based MIM has been developed to perform quantitative conductivity imaging on back-gated FETs. The research supported by this DOE grant is significant for understanding the nanoscale uniformity in technologically important materials towards energy applications.

2D materials↗

Precipitation and Latent Heating Distributions from Satellite Passive Microwave Radiometry: Method and Uncertainties - Part 1

A revised Bayesian algorithm for estimating surface rain rate, convective rain proportion, and latent heating/drying profiles from satellite-borne passive microwave radiometer observations over ocean backgrounds is described. The algorithm searches a large database of cloud-radiative model simulations to find cloud profiles that are radiatively consistent with a given set of microwave radiance measurements. The properties of these radiatively consistent profiles are then composited to obtain best estimates of the observed properties. The revised algorithm is supported by an expanded and more physically consistent database of cloud-radiative model simulations. The algorithm also features a better quantification of the convective and non-convective contributions to total rainfall, a new geographic database, and an improved representation of background radiances in rain-free regions. Bias and random error estimates are derived from applications of the algorithm to synthetic radiance data, based upon a subset of cloud resolving model simulations, and from the Bayesian formulation itself. Synthetic rain rate and latent heating estimates exhibit a trend of high (low) bias for low (high) retrieved values. The Bayesian estimates of random error are propagated to represent errors at coarser time and space resolutions, based upon applications of the algorithm to TRMM Microwave Imager (TMI) data. Errors in instantaneous rain rate estimates at 0.5 deg resolution range from approximately 50% at 1 mm/h to 20% at 14 mm/h. These errors represent about 70-90% of the mean random deviation between collocated passive microwave and spaceborne radar rain rate estimates. The cumulative algorithm error in TMI estimates at monthly, 2.5 deg resolution is relatively small (less than 6% at 5 mm/day) compared to the random error due to infrequent satellite temporal sampling (8-35% at the same rain rate).

Olson, William S.↗

Astrometric Reduction of Phoebe Using a Digital Shape Model

The Cassini Imaging Science Subsystem (ISS) has provided the most spectacular images of the Saturnian system [1] and these observations constitute a fundamental dataset of high accuracy and exceptionally long-time span for the purpose of astrometry [2]. Several elaborate astrometric efforts using Cassini ISS data have demonstrated their use for the development and maintenance of the Saturnian satellite ephemerides and have been critical in improving our understanding of their secular orbital evolution and interior properties[3].Astrometric efforts using images with well-resolved bodies often employ limb-based methods for center finding; this is proven to be robust for satellites with a uniform ellipsoidal shape. However, systematic biases are of concern for bodies that deviate considerably from tri-axial ellipsoids(e.g., moons with irregular shapes and/or extensive features such as craters, ridges, slumps and grooves). To help understand such biases, we used the Goddard Image Analysis and Navigation Tool (GIANT) [4,5]to improve the astrometric reduction of these moons. Here we apply the method to Phoebe (Saturn IX).

V Viswanathan↗

New beam line for time-of-flight medium energy ion scattering with large area position sensitive detector

A new beam line for medium energy ion mass scattering (MEIS) has been designed and set up at the Angstroem laboratory, Uppsala University, Sweden. This MEIS system is based on a time-of-flight (ToF) concept and the electronics for beam chopping relies on a 4 MHz function generator. Repetition rates can be varied between 1 MHz and 63 kHz and pulse widths below 1 ns are typically obtained by including beam bunching. A 6-axis goniometer is used at the target station. Scattering angle and energy of backscattered ions are extracted from a time-resolved and position-sensitive detector. Examples of the performance are given for three kinds of probing ions, {sup 1}H{sup +}, {sup 4}He{sup +}, and {sup 11}B{sup +}. Depth resolution is in the nanometer range and 1 and 2 nm thick Pt layers can easily be resolved. Mass resolution between nearby isotopes can be obtained as illustrated by Ga isotopes in GaAs. Taking advantage of the large size detector, a direct imaging (blocking pattern) of crystal channels are shown for hexagonal, 4H-SiC. The ToF-MEIS system described in this paper is intended for use in semiconductor and thin film areas. For example, depth profiling in the sub nanometer range for device development of contacts and dielectric interfaces. In addition to applied projects, fundamental studies of stopping cross sections in this medium energy range will also be conducted.

43 PARTICLE ACCELERATORS↗

Evaluation of the spline reconstruction technique for PET

Purpose: The spline reconstruction technique (SRT), based on the analytic formula for the inverse Radon transform, has been presented earlier in the literature. In this study, the authors present an improved formulation and numerical implementation of this algorithm and evaluate it in comparison to filtered backprojection (FBP). Methods: The SRT is based on the numerical evaluation of the Hilbert transform of the sinogram via an approximation in terms of “custom made” cubic splines. By restricting reconstruction only within object pixels and by utilizing certain mathematical symmetries, the authors achieve a reconstruction time comparable to that of FBP. The authors have implemented SRT in STIR and have evaluated this technique using simulated data from a clinical positron emission tomography (PET) system, as well as real data obtained from clinical and preclinical PET scanners. For the simulation studies, the authors have simulated sinograms of a point-source and three digital phantoms. Using these sinograms, the authors have created realizations of Poisson noise at five noise levels. In addition to visual comparisons of the reconstructed images, the authors have determined contrast and bias for different regions of the phantoms as a function of noise level. For the real-data studies, sinograms of an{sup 18}F-FDG injected mouse, a NEMA NU 4-2008 image quality phantom, and a Derenzo phantom have been acquired from a commercial PET system. The authors have determined: (a) coefficient of variations (COV) and contrast from the NEMA phantom, (b) contrast for the various sections of the Derenzo phantom, and (c) line profiles for the Derenzo phantom. Furthermore, the authors have acquired sinograms from a whole-body PET scan of an {sup 18}F-FDG injected cancer patient, using the GE Discovery ST PET/CT system. SRT and FBP reconstructions of the thorax have been visually evaluated. Results: The results indicate an improvement in FWHM and FWTM in both simulated and real point-source studies. In all simulated phantoms, the SRT exhibits higher contrast and lower bias than FBP at all noise levels, by increasing the COV in the reconstructed images. Finally, in real studies, whereas the contrast of the cold chambers are similar for both algorithms, the SRT reconstructed images of the NEMA phantom exhibit slightly higher COV values than those of FBP. In the Derenzo phantom, SRT resolves the 2-mm separated holes slightly better than FBP. The small-animal and human reconstructions via SRT exhibit slightly higher resolution and contrast than the FBP reconstructions. Conclusions: The SRT provides images of higher resolution, higher contrast, and lower bias than FBP, by increasing slightly the noise in the reconstructed images. Furthermore, it eliminates streak artifacts outside the object boundary. Unlike other analytic algorithms, the reconstruction time of SRT is comparable with that of FBP. The source code for SRT will become available in a future release of STIR.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

VARIABILITY-INDUCED MOTION IN KEPLER DATA

Variability-induced motion (VIM) is an observable effect in simultaneous astrometric and photometric measurements caused by brightness variation in one of the components of a double source or blended image, which manifests itself as a strongly correlated shift of the optical photocenter. We have processed the entire collection of Kepler long-cadence light curve data, looking for correlated signals in astrometry and photometry on the time basis of a quarter-year. Limiting the VIM correlation coefficient to 0.3, VIM events are detected for 129,525 Kepler stars in at least one quarter. Of 7305 Kepler objects of interest , 4440 are detected as VIM at least once. Known variable stars and resolved double stars have elevated rates of VIM detection. Confident VIM occurrences are found for stars with suggested superflare events, indicating possible signal contamination. We present a complete catalog of all quarterly VIM detections. This catalog should be checked for such astrophysically significant events as transits of exoplanets, new eclipsing stars, and superflares of solar-type stars.

79 ASTRONOMY AND ASTROPHYSICS↗

A versatile electron-ion coincidence spectrometer for photoelectron momentum imaging and threshold spectroscopy on mass selected ions using synchrotron radiation

We present a photoelectron-photoion coincidence (PEPICO) spectrometer named DELICIOUS II which combines a velocity map imaging apparatus with a Wiley-McLaren time of flight analyzer for the study of gas phase samples in interaction with the synchrotron radiation (SR). This versatile system is capable of providing photoelectron images on mass-selected compounds with kinetic energy resolutions of {delta}E/E=5% and a 17 eV bandwidth, as well as threshold photoelectron spectra with a measured resolution of 0.8 meV, as demonstrated on the 3p{sup -1} ionization of argon. This instrument is also employed for threshold PEPICO experiments, allowing the selection of the parent ion's internal state with sub-meV resolution for light masses (<40 amu) and with typically 2 meV resolution for a mass of 100 amu and with a mass resolving power above 200. The continuous operation of the extraction fields and the independence from the electron's time of flight are well adapted to the quasicontinuous multibunch mode of the SR. This, together with the high transmission of both the electron and ion detection, allows a high coincidence counting rate and facilitates the subtraction of false coincidences. We illustrate the spectrometer's coincidence principle of operation with examples from the valence photoionization of an Ar+Xe mixture and of CF{sub 4}.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Stochasticity of Pores Interconnectivity in Li–O 2 Batteries and its Impact on the Variations in Electrochemical Performance

While large dispersions in electrochemical performance have been reported for lithium oxygen batteries in the literature, they have not been investigated in any depth. The variability in the results is often assumed to arise from differences in cell design, electrode structure, handling and cell preparation at different times. An accurate theoretical framework turns out to be needed to get a better insight into the mechanisms underneath and to interpreting experimental results. Here, we develop and use a pore network model to simulate the electrochemical performance of three-dimensionally resolved lithium-oxygen cathode mesostructures obtained from TXM nano-computed tomography images. Here, we apply this model to the 3D reconstructed object of a Super P carbon electrode and calculate discharge curves, using identical conditions, for four different zones in the electrode and their reversed configurations. The resulting galvanostatic discharge curves show some dispersion, (both in terms of capacity and overpotential) which we attribute to the way pores are connected with each other. Based on these results, we propose that the stochastic nature of pores interconnectivity and the microscopic arrangement of pores can lead, at least partially, to the variations in electrochemical results observed experimentally.

25 ENERGY STORAGE↗

Novel energy resolving x-ray pinhole camera on Alcator C-Mod

A new energy resolving x-ray pinhole camera has been recently installed on Alcator C-Mod. This diagnostic is capable of 1D or 2D imaging with a spatial resolution of Almost-Equal-To 1 cm, an energy resolution of Almost-Equal-To 1 keV in the range of 3.5-15 keV and a maximum time resolution of 5 ms. A novel use of a Pilatus 2 hybrid-pixel x-ray detector [P. Kraft et al., J. Synchrotron Rad. 16, 368 (2009)] is employed in which the lower energy threshold of individual pixels is adjusted, allowing regions of a single detector to be sensitive to different x-ray energy ranges. Development of this new detector calibration technique was done as a collaboration between PPPL and Dectris Ltd. The calibration procedure is described, and the energy resolution of the detector is characterized. Initial data from this installation on Alcator C-Mod is presented. This diagnostic provides line-integrated measurements of impurity emission which can be used to determine impurity concentrations as well as the electron energy distribution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A new double imaging velocity focusing coincidence experiment: i{sup 2}PEPICO

The vacuum ultraviolet (VUV) beamline of the Swiss Light Source has been upgraded after two years of operation. A new, turntable-type monochromator was constructed at the Paul Scherrer Institut, which allows for fast yaw-alignment as well as quick grating change and exchange. In addition to the original imaging photoelectron photoion coincidence endstation (iPEPICO), a second, complementary double imaging setup (i{sup 2}PEPICO) has been built. Volatile samples can be introduced at room temperature or in a molecular beam, a pyrolysis source allows for radical production, and non-volatile solids can be evaporated in a heated cell. Monochromatic VUV radiation ionizes the sample and both photoelectrons and photoions are velocity map imaged onto two fast position sensitive detectors and detected in delayed coincidence. High intensity synchrotron radiation leads to ionization rates above 10{sup 5} s{sup -1}. New data acquisition and processing approaches are discussed for recording coincidence processes at high rates. The setup is capable of resolving pulsed molecular beam profiles and the synchrotron time structure temporally. The latter is shown by photoelectron autocorrelation, which displays both the 1.04 MHz ring clock frequency as well as resolving the micro-pulses with a separation of 2 ns. Kinetic energy release analysis on the dissociative photoionization of CF{sub 4} indicates a dissociation mechanism change in the Franck-Condon allowed energy range of the first ion state.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SDSS-IV MaNGA: the physical origin of off-galaxy H α blobs in the local Universe

ABSTRACT H α blobs are off-galaxy emission-line regions with weak or no optical counterparts. They are mostly visible in H α line, appearing as concentrated blobs. Such unusual objects have been rarely observed and studied, and their physical origin is still unclear. We have identified 13 H α blobs in the public data of MaNGA survey, by visually inspecting both the optical images and the spatially resolved maps of H α line for ∼4600 galaxy systems. Among the 13 H α blobs, 2 were reported in previously MaNGA-based studies and 11 are newly discovered. This sample, though still small in size, is by far the largest sample with both deep imaging and integral field spectroscopy. Therefore, for the first time we are able to perform statistical studies to investigate the physical origin of H α blobs. We examine the physical properties of these H α blobs and their associated galaxies, including their morphology, environments, gas-phase metallicities, kinematics of ionized gas, and ionizing sources. We find that the H α blobs in our sample can be broadly divided into two groups. One is associated with interacting/merging galaxy systems, of which the ionization is dominated by shocks or diffuse ionized gas. It is likely that these H α blobs used to be part of their nearby galaxies, but were stripped away at some point due to tidal interactions. The other group is found in gas-rich systems, appearing as low-metallicity star-forming regions that are visually detached from the main galaxy. These H α blobs could be associated with faint discs, spiral arms, or dwarf galaxies.

79 ASTRONOMY AND ASTROPHYSICS↗

MULTI-WAVELENGTH POLARIMETRY AND SPECTRAL STUDY OF THE M87 JET DURING 2002–2008

We present a multi-wavelength polarimetric and spectral study of the M87 jet obtained at sub-arcsecond resolution between 2002 and 2008. The observations include multi-band archival VLA polarimetry data sets along with Hubble Space Telescope ( HST ) imaging polarimetry. These observations have better angular resolution than previous work by factors of 2–3 and in addition, allow us to explore the time domain. These observations envelop the huge flare in HST-1 located 0.″86 from the nucleus. The increased resolution enables us to view more structure in each knot, showing several resolved sub-components. We also see apparent helical structure in the polarization vectors in several knots, with polarization vectors turning either clockwise or counterclockwise near the flux maxima in various places as well as showing filamentary undulations. Some of these characteristics are correlated with flux and polarization maxima while others are not. We also examine the total flux and fractional polarization and look for changes in both radio and optical since the observations of Perlman et al. (1999) and test them against various models based on shocks and instabilities in the jet. Our results are broadly consistent with previous spine-sheath models and recollimation shock models; however, they require additional combinations of features to explain the observed complexity, e.g., shearing of magnetic field lines near the jet surface and compression of the toroidal component near shocks. In particular, in many regions we find apparently helical features both in total flux and polarization. We discuss the physical interpretation of these features.

79 ASTRONOMY AND ASTROPHYSICS↗