Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TUBING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

On magnetohydrodynamic thermal instabilities in magnetic flux tubes

The stability of current-driven filamentary modes in magnetic flux tubes embedded in a plane-parallel atmosphere in LTE and in hydrostatic equilibrium is discussed. Within the tube, energy transport by radiation only is considered. The dominant contribution to the opacity is due to H- ions and H atoms (in the Paschen continuum). A region in the parameter space of the equilibrium configuration in which the instability is effective is delimited, and the relevance of this process for the formation of structured coronae in late-type stars and accretion disks is discussed.

Massaglia, S.↗

Relaminarization of the boundary layer over a flat plate in shock tube experiments

The relaminarization of the boundary layer over a flat plate in the shock tube was investigated by using the partially reflected shock wave technique. The flow Mach number was approximately 0.14, which corresponds to the inleft flow Mach number for the first row of vanes in a gas turbine. The thin film platinum heat gauges were used to measure the heat transfer rate and the Stanton number was calculated from the oscilloscope voltage traces. The Reynolds number was varied by changing the operation pressure of the shock tube and the values varied from 2.3 x 10 to the 4th to 5.3 x 10 to the 5th. For a Reynolds number range of 7 x 10 to the 4th to 3.5 x 10 to the 5th, the relaminarization of the boundary layer was observed. This phenomenon is due to the decay of the turbulence level in the flow as the reflected shock wave moves upstream from the flat plate. As the Reynolds number increased, the relaminarization was delayed and the delay was related to the turbulence generated by the reflected shock wave.

Hinckel, J. N.↗

Making Double-Bevel End Cuts on Tubes

Fixture for power saw saves time, eliminates waste, and ensures precision. Positions tube for 45 degrees end cut, then repositions for cut at 90 degrees to first cut. Roller chain holds tube in place for both cuts.

Cardenas, Joseph R.↗

Higher-Quality Weld Joints for Tube Sections

Less material in weld inserts results in better fusion. Redesigned insert for joining tubes by welding improves quality of weld. In new insert, leg of T shorter so it does not protrude into tube cavity.

Olszewski, John T.↗

Design, construction and long life endurance testing of cathode assemblies for use in microwave high-power transmitting tubes

The cathode life test program sponsored by NASA Lewis Research Center at Watkins-Johnson Company has been in continuous operation since 1972. Its primary objective has been to evaluate the long life capability of barium dispenser cathodes to produce emission current densities of 2 A sq. cm. or more in an operational environment simulating that of a highpower microwave tube. The life test vehicles were equipped with convergent flow electron guns, drift space tubes with solenoid magnets for electron beam confinement and water-cooled depressed collectors. A variety of cathode types has been tested, including GE Tungstate, Litton Impregnated, Philips Type B and M, Semicon types S and M, and Spectra-Mat Type M. Recent emphasis has been on monitoring the performance of Philips Type M cathodes at 2 A sq. cm. and Sprectra-Mat and Semicon Type M cathodes at 4 A sq. cm. These cathodes have been operated at a constant current of 616 mA and a cathode anode voltage on the order of 10 kV. Cathode temperatures were maintained at 1010 C true as measured from black body holes in the backs of the cathodes. This report presents results of the cathode life test program from July l982 through April l986. The results include hours of operation and performance data in the form of normalized emission current density versus temperature curves (Miram plots).

Batra, R.↗

Bit-error-rate testing of high-power 30-GHz traveling wave tubes for ground-terminal applications

Tests were conducted at NASA Lewis to measure the bit-error-rate performance of two 30 GHz, 200 W, coupled-cavity traveling wave tubes (TWTs). The transmission effects of each TWT were investigated on a band-limited, 220 Mb/sec SMSK signal. The tests relied on the use of a recently developed digital simulation and evaluation system constructed at Lewis as part of the 30/20 GHz technology development program. The approach taken to test the 30 GHz tubes is described and the resultant test data are discussed. A description of the bit-error-rate measurement system and the adaptations needed to facilitate TWT testing are also presented.

Shalkhauser, Kurt A.↗

Design, fabrication and performance of small, graphite electrode, multistage depressed collectors with 200-W, CW, 8- to 18-GHz traveling-wave tubes

Small multistage depressed collectors (MDC's) which used pyrolytic graphite, ion-beam-textured pyrolytic graphite, and isotropic graphite electrodes were designed, fabricated, and evaluated in conjuntion with 200-W, continuous wave (CW), 8- to 18-GHz traveling-wave tubes (TWT's). The design, construction, and performance of the MDC's are described. The bakeout performance of the collectors, in terms of gas evolution, was indistinguishable from that of typical production tubes with copper collectors. However, preliminary results indicate that some additional radiofrequency (RF) and dc beam processing time (and/or longer or higher temperature bakeouts) may be needed beyond that of typical copper electrode collectors. This is particularly true for pyrolytic graphite electrodes and for TWT's without appendage ion pumps. Extended testing indicated good long-term stability of the textured pyrolytic graphite and isotropic graphite electrode surfaces. The isotropic graphite in particular showed considerable promise as an MDC electrode material because of its high purity, low cost, simple construction, potential for very compact overall size, and relatively low secondary electron emission yield characteristics in the as-machined state. However, considerably more testing experience is required before definitive conclusions on its suitability for electronic countermeasure systems and space TWT's can be made.

Ebihara, Ben T.↗

Coaxial tube array space transmission line characterization

The coaxial tube array tether/transmission line used to connect an SP-100 nuclear power system to the space station was characterized over the range of reactor-to-platform separation distances of 1 to 10 km. Characterization was done with respect to array performance, physical dimensions and masses. Using a fixed design procedure, a family of designs was generated for the same power level (300 kWe), power loss (1.5 percent), and meteoroid survival probability (99.5 percent over 10 yr). To differentiate between vacuum insulated and gas insulated lines, two different maximum values of the E field were considered: 20 kV/cm (appropriate to vacuum insulation) and 50 kV/cm (compressed SF6). Core conductor, tube, bumper, standoff, spacer and bumper support dimensions, and masses were also calculated. The results of the characterization show mainly how transmission line size and mass scale with reactor-to-platform separation distance.

Switzer, Colleen A.↗

Tube coupling device

A first annular ring of a tube coupling device has a keyed opening sized to fit around the nut region of a male coupling, and a second annular ring has a keyed opening sized to fit around the nut of a female coupling. Each ring has mating ratchet teeth and these rings are biased together, thereby engaging these teeth and preventing rotation of these rings. This in turn prevents the rotation of the male nut region with respect to the female nut. For tube-to-bulkhead locking, one facet of one ring is notched, and a pin is pressed into an opening in the bulkhead. This pin is sized to fit within one of the notches in the ring, thereby preventing rotation of this ring with respect to the bulkhead.

Myers, William N.↗

Self-consistent inclusion of space-charge in the traveling wave tube

It is shown how the complete field of the electron beam may be incorporated into the transmission line model theory of the traveling wave tube (TWT). The fact that the longitudinal component of the field due to the bunched beam is not used when formulating the beam-to-circuit coupling equation is not well-known. The fundamental partial differential equation for the traveling wave field is developed and compared with the older (now standard) one. The equation can be solved numerically using the same algorithms, but now the coefficients can be updated continuously as the calculation proceeds down the tube. The coefficients in the older equations are primarily derived from preliminary measurements and some trial and error. The newer coefficients can be found by a recursive method, since each has a well defined physical interpretation and can be calculated once a reasonable first trial solution is postulated. The results of the new expression were compared with those of the older forms, as well as to a field theory model to show the ease in which a reasonable fit to the field prediction is obtained. A complete summary of the existing transmission line modeling of the TWT is given to explain the somewhat vague ideas and techniques in the general area of drifting carrier-traveling circuit wave interactions. The basic assumptions and inconsistencies of the existing theory and areas of confusion in the general literature are examined and hopefully cleared up.

Freeman, Jon C.↗

Microstructures of niobium-germanium alloys processed in inert gas in the 100 meter drop tube

The 100 meter drop tube at NASA's Marshall Space Flight Center has been used for a series of experiments with niobium-germanium alloys. These experiments were conducted with electromagnetic levitation melting in a 200 torr helium environment. Liquid alloys experienced large degrees of undercooling prior to solidification in the drop tube. Several interesting metastable structures were observed. However, the recalescence event prevented extended solid solubility of germanium in the A-15 beta phase. Liquids of eutectic composition were found to undercool in the presence of solid alpha and solid Nb5Ge3.

Bayuzick, R. J.↗

Particle propagation, wave growth and energy dissipation in a flaring flux tube

Wave amplification by downgoing particles in a common flare model is investigated. The flare is assumed to occur at the top of a coronal magnetic flux loop, and results in the heating of plasma in the flaring region. The hot electrons propagate down the legs of the flux tube towards increasing magnetic field. It is simple to demonstrate that the velocity distributions which result in this model are unstable to both beam instabilities and cyclotron maser action. An explanation is presented for the propagation effects on the distribution, and the properties of the resulting amplified waves are explored, concentrating on cyclotron maser action, which has properties (emission in the z mode below the local gyrofrequency) quite different from maser action by other distributions considered in the context of solar flares. The z mode waves will be damped in the coronal plasma surrounding the flaring flux tube and lead to heating there. This process may be important in the overall energy budget of the flare. The downgoing maser is compared with the loss cone maser, which is more likely to produce observable bursts.

White, S. M.↗

A comparison of three types of pulse tube refrigerators - New methods for reaching 60 K

The three types of pulse tube refrigerator, namely the resonant, basic, and orifice designs, are compared with each other and with such common refrigerators as the Joule-Thomson and Stirling types, using an apparatus able to measure their intrinsic behavior from 30 to 300 K. Orifice pulse tubes are found capable of reaching 60 K temperature drops in a single stage. Additional advantages of the type are (1) a single, room-temperature moving part, (2) the use of moderate pressures and pressure ratios, (3) good intrinsic efficiency, and (4) the ability to operate several stages from the same pressure wave generator. The low refrigeration rate/unit mass flow means, however, that better regenerator units are required.

Radebaugh, Ray↗

Pyrotechnic Tubing Connector

Tool forms mechanical seal at joint without levers or hydraulic apparatus. Proposed tool intended for use in outer space used on Earth by heavily garbed workers to join tubing in difficult environments. Called Pyrotool, used with Lokring (or equivalent) fittings. Piston slides in cylinder when pushed by gas from detonating pyrotechnic charge. Impulse of piston compresses fittings, sealing around butting ends of tubes.

Graves, Thomas J.↗

Coaxial tube array space transmission line characterization

The coaxial tube array tether/transmission line used to connect an SP-100 nuclear power system to the space station was characterized over the range of reactor-to-platform separation distances of 1 to 10 km. Characterization was done with respect to array performance, physical dimensions and masses. Using a fixed design procedure, a family of designs was generated for the same power level (300 kWe), power loss (1.5 percent), and meteoroid survival probability (99.5 percent over 10 yr). To differentiate between vacuum insulated and gas insulated lines, two different maximum values of the E field were considered: 20 kV/cm (appropriate to vacuum insulation) and 50 kV/cm (compressed SF6). Core conductor, tube, bumper, standoff, spacer and bumper support dimensions, and masses were also calculated. The results of the characterization show mainly how transmission line size and mass scale with reactor-to-platform separation distance.

Switzer, Colleen A.↗

Bit-error-rate testing of high-power 30-GHz traveling-wave tubes for ground-terminal applications

Tests were conducted at NASA Lewis to measure the bit-error-rate performance of two 30-GHz 200-W coupled-cavity traveling-wave tubes (TWTs). The transmission effects of each TWT on a band-limited 220-Mbit/s SMSK signal were investigated. The tests relied on the use of a recently developed digital simulation and evaluation system constructed at Lewis as part of the 30/20-GHz technology development program. This paper describes the approach taken to test the 30-GHz tubes and discusses the test data. A description of the bit-error-rate measurement system and the adaptations needed to facilitate TWT testing are also presented.

Shalkhauser, Kurt A.↗

Operating characteristics of a 60 cm and a 10 cm electric arc-driven shock-tube

This paper describes the current status of the operating characteristics of the electric arc-driven shock-tube facility at Ames Research Center, focusing on its potential usefulness in the current and anticipated future applications. The paper specifically addresses the questions as to: (1) how well the behavior of the arc driver is understood and controlled, (2) how well the facility is equipped to test low-density, very-high-velocity nonequilibrium flow regimes, and (3) how closely the facility is expected to produce an equilibrium hypersonic flow when operated in shock-tunnel modes. For these issues, it is shown that: (1) a plasma kinetics model of the exploding wire closely describes the arc behavior in the driver, (2) the facility can produce a spectroscopically-clean flow in a low density regime with a shock velocity of 13 km/sec in air when used with an aluminum driven tube, and (3) when operated as a shock-tunnel, the high enthalpy flow in the test section is expected to deviate only slightly from the perfect equilibrium flow conditions at enthalpies corresponding to flight speeds of 5 km/sec or less.

Sharma, Surendra P.↗

Boiling oxygen experimental studies in an electrically heated tube

An experimental study was made of subcooled flow boiling with LOX; data were obtained with thermocouples attached to the walls of an electrically heated tube through which the LOX flowed. Pressure levels in the tube ranged from 200 psia to supercritical values, and the cooling level varied from the saturated condition to 50 F. Reynolds numbers ranged from 1.5 x 10 to 3.5 x 10 to the 5th. Results show that an increase in either pressure, subcooling level, or Reynolds number produces an increase in the film boiling heat transfer coefficient. Data for this range of parameters were found to correlate in terms of the Stanton number vs (T sub w - T sub s)/(T sub s - T sub b), where T is temperature, w is the wall, s is the saturated condition, and b is the bulk.

Peroulias, C.↗